silex technology DS-700 USB Device Server User Guide
PDF
Dokument
Werbung
Werbung
Step 1. Power on How to power on the DS-700 is explained: Network DS-700 Setup Guide * If the DS-700 has been used in another | Ethernet HUB = \ network, reset it to factory default first O jo (see below for details). USB cable Connect the DS-700 to the Ethernet HUB using a network cable (1). 1. The following items are required. Network Cable (1) Network cable Ethernet HUB Power Outlet 05-700 [|] _ | IS = English silex Connect the DS-700 to the USB device 4. Connect the AC adaptor to the DS-700 (3) 5 | If the USB device requires external CE ohn using a USB cable (2). and the AC plug to the power outlet (4). power, use the power supply cable (6). (4) fecnnotogy WA106280XX Check that POWER LED and LINK LED S y * There are USB devices not supported due to turn on (5). the driver specification. Please check the * Be sure to use the AC adaptor that came AC Adaptor | | latest compatibility information on our ith the DS-700. Thank you for purchasing the USB Device Server “DS-700". website. и This Setup Guide provides information оп how to configure * For each USB port, only 1 device can run on AS POWER LED and use the DS-700 in your network. bus power. (5) * The USB3.0 port of DS-700 does not support LINK LED connection with a USB HUB, USB HUB embedded device and USB video converter. Package Contents USB Device . N Factory Default Configuration ) N [105-700 | JAC adaptor [Setup Guide (this document) LIGPL Inquiry Card Remove the AC plug from the power Press and hold the push switch while Release the push switch when the LINK outlet (1). inserting the AC plug back into the LED(orange) turns off. (3) (1) Power Outlet power outlet (2). Continue holding. The factory default configuration is LINK LED = aD completed. DS-700 ) <— When the LINK LED(orange)(3) turns on, the factory default configuration begins. Name of Parts * Do not release the push switch until the LINK LED(orange) turns off. AC Adaptor Push Switch oa port connector 2) — Push Switch LZ \ y NE Y, a Г | | a [2 Г . 1 | O 7 — Step 2. Configuration = h | h d load th | d If b o This section explains how to download the necessary utilities and user's manual from our website. USB3.0 port ( 2-1. Downloading the Necessary Items ) LINK LED POWER LED 1. Access the URL below from the computer you are using to Я Go to the Support page and select the product model. EJ Download the utilities and documents below to your computer. Network port configure the DS-700. Device Server Setup URL: https://www.silextechnology.com - Utilit ps:// 9y / | Product Model | DS-700 | y SX Virtual Link DS-700 User's Manual User's Manual Device Server Configuration guide Step 1. Power on Connect the DS-700 to your network. ~ < 2-2. Configuration ) Step 2. Configuration Download the necessary utility and configure the DS-700 How to configure the DS-700 is explained: * Before moving on to EE, please temporarily 1. Extract the Device Server Setup file Я Configure the DS-700 using Device using it. By default, the DS-700 is configured to automatically obtain an disable the firewall function of the computer you that you have downloaded at 2-1. Server Setup utility according to \ 7 IP address from the DHCP server. If the DHCP server is installed use for configuration. Some of the methods to Downloading the Necessary Items. instructions on Device Server y on your network, the configuration will not be necessary. In disable the firewall are provided in the FAQ on Configuration guide (PDF file). such a case, go on to install the SX Virtual Link (see the back). our homepage. N - Commercial security software's firewall function Step 3. Using the USB Devices over Network Start using the USB devices by connecting it using SX Virtual Link. When you want to configure the IP address manually or you are not sure if there is the DHCP server on your network, move on to EX Step 3. Using the USB Devices over Network « 3-1. Installing the SX Virtual Link ) The SX Virtual Link is the software program to make a communication between your computer and the USB devices connected to the device server. To use the USB devices over the network, you have to connect to or disconnect from it using the SX Virtual Link. See the contained PDF manual (SX Virtual Link Installation) to install the SX Virtual Link. № the SX Virtual Link is not installed to your computer, install it by KM Extract the SX Virtual Link file that you have downloaded following the instructions in this section. at 2-1. Downloading the Necessary Items. The SX Virtual Link installer will restart your computer after it is installed. Make sure that you finished all software programs on your computer before starting the installation. € 3-2. Basic Use ofthe SX Virtual Link ) Click the application icon (@) in the task tray or go to the Start menu and click silex Tools - SX Virtual Link from the app list. Starting the SX Virtual Link * When using the USB device for the first time, you may need to install the device driver for that USB device. Select a USB device and click the Connect button ( (©). The USB device can be connected when the status icon [ © ] is displayed. © SX Virtual Link - О x Connecting the USB devices FA The Plug and Play function automatically creates an appropriate environment to use the selected device. BRAIN EN VW SX Virtual Link To install the driver, refer to the operating manual that came with the USB device, or follow the instructions on the screen displayed after clicking the Connect button in the SX Virtual Link. и * The USB device can also be connected by selecting and double-clicking it on the SX Virtual Link. ~ The USB device will be ready to use once the status icon has changed to [ &2 ]. See the operating manual that came with your USB device for how to use it. Г N * If a device server is not displayed on a list, please click the Refresh button (|.%.. ). * Do not unplug the USB cable or network cable, or click * Only one device can be connected at a time. When the USB device is in use by another computer, the Disconnecting the USB devices Accessing Online Help When you have finished using the USB device, disconnect the device by selecting it and clicking the Disconnect button ( (y) ). *The USB device can also be disconnected by selecting and double-clicking it on the SX Virtual Link. Click the Help button ( ) and select Help from the menu displayed. NE the Disconnect button ( (43) on the SX Virtual Link while the USB device is in use. J @ 5X Virtual Link — im] x VW SX Virtual Link Ll dde dp 05700-014554 [84:25:3F:01:45:54 05-700] = 47 © You are connected: — Ol A т @ SX Virtual Link | status icon [(@)] is displayed, which means that the USB device is not available now. Ne y (Customer Support ) USA : silex technology america, Inc. E-mail : [email protected] URL : https://www.silextechnology.com/ cH ME > EA: @ Phone : +1-657-218-5199 q Help ) silex technology web site FAQ Page Europe : silex technology europe GmbH ÓN About SX Virtual Link a E-mail : [email protected] Г MEE URL : https: //www.silextechnology.com/ Phone : +49 -2154-88967-0 Ne ">
/
Herunterladen
Nur eine freundliche Erinnerung. Sie können das Dokument direkt hier ansehen. Aber was am wichtigsten ist, unsere KI hat es bereits gelesen. Sie kann komplexe Dinge einfach erklären, Ihre Fragen in jeder Sprache beantworten und Ihnen helfen, auch in den längsten oder kompliziertesten Dokumenten schnell zu navigieren.
Werbung