Xenon Lamp Listing

Xenon Lamp Listing
Xenon Lamp Listing
High performance short arc Xenon lamp solutions
At the heart of Christie’s CP Series Digital Cinema projector line
are Christie’s CDXL high performance short-arc Xenon lamps.
These lamps have been optimized for use with the CP Series
Digital Cinema projectors. With increased brightness in the same
form factor as standard cinema grade lamps, CDXL lamps provide
higher output and brightness in a more cost-efficient package.
To get a true representation of color in any professional
environment, you need a truly remarkable light source. Christie’s
Xenon Arc Lamps offer stable color temperature, a wide range
of power levels and excellent color rendition. Christie lamps are
backed by the best warranty in the industry.
1 H I G H
P E R F O R M A N C E
X E N O N
Warner Bros. Movie World, Australia’s only world-class movie studio
theme park opened in the Fall of ‘05 with an all new, cutting-edge
attraction starring Shrek®. The DreamWorks® Shrek 4D Adventure is a 3D
film like no other using specially designed “Ogre Vision” glasses, motioncontrolled seating and Christie’s acclaimed high resolution CP2000 DLP
Cinema® projectors to project the latest ogre-whelming adventure.
To achieve high resolution and high brightness projection for this stateof-the-art 3D animation, the technical team at Warner Bros. Movie
World installed two high resolution Christie CP2000 projectors in the
L A M P S
main theatre with an uncompressed digital video server in a custom
configuration. The projectors display high resolution stunning 3D
images onto the 15m (49ft) wide Harkness screen.
“The Christie CP2000 projectors are amazing. They’re brilliant with
their true-to-life colors. They’re an absolute pleasure to work with and
are definitely the future of film. So far, they’ve operated without error
for over 500 hours and the Shrek 4D Adventure is now running at 21
shows a day,” says Terence Brown, Group Chief Projectionist, Technical
Supervisor, Ride Photo Systems, Warner Village Theme Parks.
2
3 X E N O N
S H O R T- A R C
L A M P
C H A R A C T E R I S T I C S
WAVELENGTH DIAGRAM
Ultraviolet Radiation
Infared Radiation
Visible Radiation
750mm
375mm
1500mm
6000mm
Xenon Short Arc Lamps
Engineered for superior performance in all cinema applications.
Spectral distribution
diagram
Luminous intensity
distribution curve
Construction of a Xenon
short arc lamp
Spectrum comparison between Xenon lamp
and daylight
Variation spectral distribution
corresponding to input
variation
Luminous intensity
distribution curve
along the arc axis
Christie’s digital cinema projectors light up screens around the world
4
The Christie CP Series Digital Cinema projectors, powered by CDXL Xenon short arc lamps, set
new levels of performance for Digital Cinema technology. Choices in brightness levels and power
levels offer flexibility for a variety of screen sizes in existing theater infrastructure.
The use of a CDXL lamp is guaranteed against defect while operating in any Christie CP Series
Digital Cinema projector.
CDXL short arc Xenon lamps
Christie’s digital cinema projectors light up
screens around the world with the latest
digital releases from major studios. With
the improved performance of cost-efficient
CDXL short-arc Xenon lamps, the power
consumption of these lamps is lower than
standard Xenon lamps.
Also available:
Part number
Description
003-001976-01
•
CDXL-20SD
003-001165-01
•
CDXL-30SD
See Christie Rep
•
CDXL-60SD
As one of the top movie theatre operators
in the U.S., Cinemark’s primary focus has
always been to give its customers a fun
and exciting movie-going experience.
5 C D X L
CDXL-20
S P E C I F I C A T I O N S
(003-000598-02)
TECHNICAL DATA
•
Improved performance
•
Cost-efficient
•
Purpose built for cinema applications
OPERATIONAL INFORMATION
Lamp
Avg life
Warranty
Performance gain
3500
0-1200 – 100%
1201-2400 – Pro-rated
26%
CDXL-20
CDXL-30
Rated input power
W
2000
Rated current
A
80
Operating current range
A
60 - 85
Rated voltage
V
25
Cold arc gap
mm
4.5
Lamp length (L1)
mm
403
Lamp length (L2)
mm
350
LCL (L3)
mm
161.5
Bulb diameter
mm
ø 55
Base diameter
mm
ø 27
Cathode pin diameter
mm
ø M14 X 1.5
Anode pin diameter
mm
ø 14
º
±5º
Horizontal
Base surface temperature
ºC
200ºC max
Forced air cooling
m/s
10 to 13
(003-000599-02)
TECHNICAL DATA
•
Improved performance
•
Cost-efficient
•
Purpose built for cinema applications
OPERATIONAL INFORMATION
Lamp
CDXL-30
Avg life
Warranty
Performance gain
2500
0-720 – 100%
27%
721-1400 – Pro-rated
Rated input power
W
3000
Rated current
A
110
Operating current range
A
90 - 120
Rated voltage
V
27
Cold arc gap
mm
5.5
Lamp length (L1)
mm
403
Lamp length (L2)
mm
350
LCL (L3)
mm
161.5
Bulb diameter
mm
ø 60
Base diameter
mm
ø 28
Cathode pin diameter
mm
ø M14 X 1.5
Anode pin diameter
mm
ø 14
º
±5º
Horizontal
Base surface temperature
ºC
200ºC max
Forced air cooling
m/s
10 to 13
High performance CDXL short-arc Xenon lamps
CDXL-45
6
(003-000600-02)
TECHNICAL DATA
•
Improved performance
•
Cost-efficient
•
Purpose built for cinema applications
OPERATIONAL INFORMATION
Lamp
Avg life
Warranty
Performance gain
1000
0-500 – 100%
501-900 – Pro-rated
38%
CDXL-45
Rated input power
W
4500
Rated current
A
145
Operating current range
A
95 - 155
Rated voltage
V
31.5
Cold arc gap
mm
6
Lamp length (L1)
mm
417
Lamp length (L2)
mm
381
LCL (L3)
mm
165.5
Bulb diameter
mm
ø 70
Base diameter
mm
ø 30
Cathode pin diameter
mm
ø M14 X 1.5
Anode pin diameter
mm
ø 14
º
±5º
Horizontal
Base surface temperature
ºC
200ºC max
Forced air cooling
m/s
10 to 13
CDXL-60
(003-000601-02)
TECHNICAL DATA
•
Improved performance
•
Cost-efficient
•
Purpose built for cinema applications
OPERATIONAL INFORMATION
Lamp
CDXL-60
Avg life
Warranty
Performance gain
900
0-300 – 100%
11%
301-600 – Pro-rated
Rated input power
W
6000
Rated current
A
155
Operating current range
A
105 - 165
Rated voltage
V
39
Cold arc gap
mm
8
Lamp length (L1)
mm
417
Lamp length (L2)
mm
381
LCL (L3)
mm
165.5
Bulb diameter
mm
ø 70
Base diameter
mm
ø 30
Cathode pin diameter
mm
ø M14 X 1.5
Anode pin diameter
mm
ø 14
º
±5º
Horizontal
Base surface temperature
ºC
200ºC max
Forced air cooling
m/s
10 to 13
7 C X L
L A M P
L I S T
Christie understands the cinema industry. We know our customers
personally. With no margin for error, the show must always go on
- and our CXL Short-Arc Xenon lamps are integral to that promise.
Christie brings over 75 years of experience, knowledge and value to
your cinema business. From concept to completion, Christie is the
undisputed leader in creating solutions for your cinema.
PRODUCT REFERENCE NOTES & SUFFIXES
CXL-900
CXL-4200A
•
Consult factory for proper application
CXL-10
CXL-45
•
A – with Anode Cable
CXL-10S
CXL-50SC
CXL-10SC
CXL-60
pins / With Anode Cable
CXL-1600A
CXL-60SC
LC - Longer Lamp Length / Lug Type Connector / 14mm pins / With Anode Cable
CXL-16S
CXL-70
CXL-16SC
CXL-70SC
S – Short Lamp Length / Threaded Tip on Cathode end and 11mm pin on Anode End/ No Cables
•
•
SC - Short Lamp Length / 8mm Cathode and 9.5mm Anode •
•
R - Longer Lamp Length / With Both Cables
No Suffix - Threaded Tip on Cathode end and 14mm pin on Anode End/ No Cables
•
CXL-20
CXL-20SC
CXL-25
CXL-2500LC
CXL-25SC
CXL-30
CXL-30R
CXL-30SC
CXL-40
CXL-40SC
Christie Core Lamps
CXL-20R
• CXL-20
• CXL-25
• CXL-30
• CXL-40
• CXL-45
• CXL-60
CXL short-arc Xenon lamps for cinema projection
8
Hoyts Cinema, Australia
CXL-20R
CXL-20SC
CXL-20
CXL-1600A
CXL-16S
CXL-10
CXL-16SC
CXL-10SC
S P E C I F I C A T I O N S
CXL-10S
C X L
CXL-900
9 Rated input power
W
900
1000
1000
1000
1430
1430
1600
2000
2000
2000
Rated current
A
45
45
50
50
65
65
65
80
80
70
Operating current range
ADC
30 - 45
35 - 50
30 - 55
30 - 55
45 - 70
45 - 70
45 - 70
60 - 85
50 - 85
50 - 85
Rated voltage
VDC
20
20
20
20
22
22
24
25
25
29
Cold arc gap
mm
4.0
5.0
4.2
4.2
4.0
4.0
4.8
6.0
6.0
6.0
Overall lamp length
mm
330
330
235
236
236
235
365
375
342
370
Lamp length
between
connector faces
mm
275
275
205
222
222
205
320
320
302
320
Lamp length
from rear connector
face to arc center
mm
125
125
96.5
96.5
96.5
96.5
145
145
147
145
Bulb diameter
mm
40
45
40
40
48
48
55
55
60
55
Cathode pin diameter
mm
12
M14XP1.5
5/16-18UNC
5/16-18UNC
5/16-18UNC
5/16-18UNC
12
M14XP1.5
7.9
12
Anode pin diameter
mm
10
14
11
N/A
N/A
11
10
14
9.4
10
Cables included
mm
Both
No
No
Anode
Anode
No
Anode
No
Anode
Both
Vertical tolerance
±º
30
N/A
N/A
N/A
N/A
N/A
30
15
30
30
Horizontal tolerance
±º
N/A
15
15
15
15
15
N/A
15
30
30
4000
4200
4500
5000
6000
6000
7000
7000
90
83
90
100
100
100
130
135
140
150
140
160
160
160
160
70 - 95
60 - 85
70 - 100 80 - 110
60 - 110
60 - 100
100 - 140
80 - 150
100 - 150
100 - 160
110 - 150
110 - 170
110 - 170
110 - 170
110 - 170
24
27
28
27
30
30
29
29
30
30
35
37
37
43
43
7.0
7.0
6.0
7.0
6.5
7.0
7.0
7.0
7.0
8.0
8.0
9.0
9.0
11.0
11.0
403
433
345
403
342
428
433
410
428
433
410
417
433
417
433
350
380
300
350
302
382
380
370
380
380
370
381
392
381
392
165
171
147
165
147
171
170
174.5
170
170
171
170
176
170
176
60
57
60
60
60
70
70
70
70
80
70
80
80
80
80
M14XP1.5
14
7.9
M14XP1.5
7.9
14
M14XP1.5
7.9
14
M14XP1.5
7.85
M14XP1.5
7.85
M14XP1.5
7.85
14
13
9.4
14
9.5
13
14
9.4
13
14
9.4
14
9.4
14
9.4
No
Anode
Anode
N/A
Anode
Both
No
Anode
Both
No
Anode
No
Anode
No
Anode
15
30
15
N/A
30
30
N/A
N/A
N/A
N/A
N/A
N/A
15
N/A
15
15
30
15
15
30
30
15
15
15
15
15
15
15
15
15
CXL-70
CXL-60
CXL-45
CXL-40SC
CXL-40
CXL-70SC
4000
CXL-60SC
3000
CXL-50SC
3000
CXL-4200A
3000
CXL-30R
2500
CXL-30SC
2500
CXL-30
CXL-25SC
2500
CXL-25
CXL-2500LC
10
11
M A N U F A C T U R E R ’ S
Christie Xenolite Lamps
WATTAGE
C R O S S
R E F E R E N C E
(Model numbers subject to change without notice)
MODEL NO.
OSRAM
LTI
1000
CXL-10
XBO 1000W/HTP OFR
LTIX 1000W-HTP
1000
CXL-10S
XBO 1000W/HS OFR
LTIX 1000W-HS
1000
CXL-10SC
XBO 1000W/HSC OFR
LTIX 1000W-HSC
1600
CXL-16S
XBO 1600W/HS OFR
LTIX 1600W-HSCH
1600
CXL-16SC
XBO 1600W/HSC OFR
LTIX 1600W-HSCCH
2000
CXL-20
XBO 2000W/HTP OFR
LTIX 2000W-HTPCH
2000
CXL-20R
XBO 2000W/H OFR
LTIX 2000-HCH
2000
CXL-20SC
XBO 2000W/HS OFR
LTIX 2000W-HSXH
2500
CXL-25
NONE
NONE
2500
CXL-25SC
XBO 2500W/HS OFR
LTIX 2500W-HSCH
3000
CXL-30
XBO 3000W/HTP OFR
LTIX 3000W-HTPCH
3000
CXL-30R
XBO 3000W/H OFR
LTIX 3000W-HCH
3000
CXL-30SC
XBO 3000W/HS OFR
LTIX 3000W-HSXH
4000
CXL-40
XBO 4000W/HTP OFR
LTIX 4000W-HTPCH
4000
CXL-40SC
XBO 4000W/HS OFR
LTIX 4500W-HSCH
4500
CXL-45
NONE
NONE
5000
CXL-50SC
NONE
L5000W-HS
6000
CXL-60
NONE
LTIX 6000W-HTP
6000
CXL-60SC
NONE
LTIX 6002W-HS
7000
CXL-70
NONE
NONE
7000
CXL-70SC
XBO 7000W/HS OFR
LTIX 7000W-HSCH
900
CXL-900
XBO900W OFR
LTIX 900W-H
1600
CXL-1600A
XBO 1600W/CA OFR
LTIX 1600W-H
2000
CXL-20R
XBO 2000W/H OFR
LTIX 2000W-H
2500
CXL-2500 (LC)
XBO 2500W OFR
LTIX 2500W-H
3000
CXL-30R
XBO 300W/H OFR
LTIX 3000W-H
4000
CXL-4200
XBO 4000W OFR
LTIX 4200W-HC
4200
CXL-4200A
XBO 4200W/CA OFR
LTIX 4200W-H
CXL short-arc Xenon lamps for cinema projection12
Champion Xenolite Bulb Warranty
MODEL CXL
FULL CREDIT HRS
PRO-RATED CREDIT HRS
-10S, -10SC, -16S, -16SC
0 - 1000
1001 - 2000
-10, -20, -20R, -20SC
0 - 1200
1201 - 2400
-30, -30R, -30SC
0 - 750
751 - 1500
-25, -25SC
0 - 750
751 - 1500
-40, -40SC, -45
0 - 600
601 - 1200
-50SC
0 - 500
501 - 1000
-60, -60SC
0 - 300
301 - 600
-70, -70SC
0 - 250
251 - 500
900, 900A, 1600A
0 - 1200
1201 - 2400
2500LC
0 - 900
901 - 1800
4200A
0 - 600
601 - 1200
LIGHT SPECTRUM
12
New warranty hours
effective Jan 1, 2006
Lamps purchased after January 1, 2006 will be
subject to the above warranty life hours and the
following standard terms and conditions*
* Credit is subject to the following conditions
or exclusions:
1. DAMAGE IN SHIPMENT IS NOT COVERED BY WARRANTY. Bulbs must be inspected upon arrival. If damaged, a claim must be filed immediately with the carrier.
2. Defective bulb (all metal parts if bulb is shattered) must be returned to Christie, freight prepaid and insured for the amount of anticipated credit, together with completed warranty form.
3. Bulb must have been operated with the correct polarity, not below rated minimum current, nor above maximum rated power, in accordance with applicable air cooling requirements and other operating conditions.
4. If the bulb is operated with a spherical reflector, the reflected cathode hot spot must not be superimposed on either of the bulb’s electrodes.
5. INSPECTION AND TEST AT CHRISTIE MUST
VERIFY CLAIM.
6. Christie shall not be reliable for any consequential damage other than REFLECTOR under CXL lamp types or REFLECTOR, UV FILTER AND INTEGRATOR, if used in CP2000 series projectors.
7. Any credit due is based on the Christie net selling price and warranty applicable at time of purchase of the defective bulb and issued to the original purchaser. New, unused lamps may be returned only if within 2 years from original date of purchase. Lamps over 5 years old will not be covered under warranty regardless ours used.
8. In the event of a warranty dispute, the final decision rests solely with Christie.
13 S A F E T Y
I N F O R M A T I O N
Warning
Do not operate the lamp in close proximity to paper, cloth or
other combustible material, nor cover it with such materials, even
immediately after it is turned off. Otherwise it could cause a fire.
Operate the lamp in the position indicated in the column of the
burning position in this certificate. Otherwise it could cause
overheating of the lamp house, lamp breakage or short lamp life.
As the lamp is filled with high pressure xenon gas, do not hit the
lamp against anything, apply excessive stress or scratch the lamp.
Otherwise it could cause an injury if it bursts.
Thoroughly ventilate the area or the room when operating the lamp in
an oxygen atmosphere (in air), except in the case of ozone-free lamps.
If ozone is inhaled, it could cause headaches, nausea, dizziness, etc.
The lamp must be operated in a splinter-scatter-proof lamp
house. Do not open the lamp house while the lamp is operating or
immediately after it is turned off. Otherwise it could cause an injury
if it bursts.
Turn off the electrical power before installing, removing or cleaning
the lamp house. Otherwise it could cause electrical shock.
Do not touch the lamp while it is operating or immediately after it
is turned off because it is extremely hot. Otherwise it could cause
a burn.
Do not operate the lamp in an atmosphere containing an inflammable
substance, such as gasoline, spray containing volatiles, thinner,
lacquer or dust. Otherwise it could cause a fire or an explosion.
As the lamp is filled with high pressure xenon gas, it must be kept in
the provided protective case when transporting, storage or disposal.
Otherwise it could cause an injury, if it bursts.
The lamp that has been used for the rated service life is more likely
to break and burst because of the deteriorated glass condition.
Therefore, follow the instructions in this leaflet for replacement and
disposal of the used lamp. Otherwise it could cause injury if it bursts.
Wear a protective mask, protective gloves and a thick long-sleeved
shirt, when the lamp is handled or installed and removed to/from
the lamp house.
The protective mask which covers the carotid, must be made with
thicker than 2mm polycarbonate or another material with same
strength or more.
Gloves and a thick long-sleeved shirt must be made with rippingproof and piercing-proof material like aramid fiber. Otherwise it could
cause an injury if the lamp bursts.
During operation the lamp emits intense UV radiation which is harmful
to the eyes and skin. Do not look directly or indirectly at the operating
lamp. Otherwise it could cause eye aches or eyesight problems.
Do not directly or indirectly expose your skin to the lamp light.
Otherwise it could cause inflammation of the skin.
Important operation notes
The lamp must be operated under the specified use conditions such
as lamp current, lamp voltage and cooling condition.
Keep the lamp base temperature below 200ºC or maximum
temperature if specified by following cooling conditions designated.
14
Disposal
Caution
• The used lamp must be kept in the provided protective case until disposal by
breaking the glass part. Otherwise it could cause injury.
Handling
• When the lamp is soiled with fingerprints by touching glass envelope with bare hand or dust, clean it with alcohol-soaked cloth. Otherwise it could cause burst or short lamp life.
• Do not subject the lamp to vibration or shock, since it is a glass product. Otherwise it could burst or shorten lamp life.
• The lamp is filled with high pressure Xenon gas. Disposal without breaking the glass part may result in lamp burst. Follow the instructions below to prevent harmful repercussions:
WEAR A PROTECTIVE MASK, PROTECTIVE GLOVES AND A LONG
SLEEVED SHIRT WHEN HANDLING THE LAMP.
1. The used lamp must be kept in the provided protective case; the case must be securely locked by the metallic stopper.
Installation
• Install the lamp in the correct polarity. Otherwise it could cause burst, overheating of the lamp house or short lamp life.
• Do not apply excessive stress such as twisting or bending when installing 2. Place the used lamp in the protective case into the provided box. Firmly attach the tape of the paper case to make certain the case will not open if the lamp is dropped.
the lamp. Otherwise it could cause an injury if it bursts.
3. From about one (1) meter in height, drop the provided box, with the lamp and protective case inside, onto a hard floor.
• Do not use any tools to tighten connections when fixing the lamp, use only 4.Shake the box to determine if the lamp is broken.
hands. Otherwise it could cause breakage.
• Fix the lamp and its lead wire firmly to the terminals. Before fixing, make sure that there is no rust, burning or discoloration where electrical connections are made between the lamp and the lamp house. Otherwise it could cause overheating by poor electrical connection.
• Install the lamp with the protective cover. Be sure to remove the protective cover from the lamp after installation.
• Cover the lamp with the protective cover before removing the lamp from the lamp house. Otherwise it could cause an injury if the lamp bursts.
Operation
• Do not open the lamp house for at least ten (10) minutes after the lamp is turned off. Otherwise it could cause an injury if it bursts.
• Remove the lamp from the lamp house after making sure it has been turned off for more than 15 minutes and the lamp and lamp house have cooled down. Otherwise, it could cause an injury or burn if the lamp bursts.
• Use a suitable lamp house and power supply (ballast). Operate a lamp in the range of wattage designated.
Storage
Store the lamp under the following conditions.
Temperature: – 25 ~ 65°C
Humidity: 20 ~ 95%RH
without condensation
5.Dispose of as industrial waste. Dispose separately where metal and glass must be disposed of separately.
Corporate offices
Worldwide offices
USA – Cypress
ph: 714-236-8610
United Kingdom
ph: +44 118 977 8000
Hungary/Eastern Europe­­
ph: +36 (0) 1 47 48 100
Beijing
ph: +86 10 6561 0240
Canada – Kitchener
ph: 519-744-8005
Germany
ph: +49 2161 664540
Singapore
ph: +65 6877 8737
Korea
ph: +82 2 702 1601
France
ph: +33 (0) 1 41 21 44 04
Shanghai
ph: +86 21 6278 7708
Japan
ph: +81 3 3599 7481
For the most current specification information, please visit www.christiedigital.com
Copyright 2008 Christie Digital Systems, Inc. All rights reserved. All brand names and product names are trademarks, registered trademarks
or tradenames of their respective holders. Canadian manufacturing facility is ISO 9001 and 14001 certified. Performance specifications are typical.
Due to constant research, specifications are subject to change without notice. Printed in Canada on recycled paper. 2316 Feb 08
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement