MedKlinn O3 Jetspray User Manual
MedKlinn O3 Jetspray is a powerful device that converts oxygen into ozone and infuses it into water for disinfection and deodorization. It eliminates bacteria, viruses, and mold, removes biofilm build-up, and dissolves oil and grease. This makes it ideal for various applications like cleaning surfaces, sanitizing tools, and removing odors.
PDF
Download
Document
Advertisement
Advertisement
O3 Jetspray USER MANUAL TABLE OF CONTENT 1. Safety Precautions 2. Device Identification 3. System Overview 4. Getting Started 5. Basic Maintenance 1 3 9 12 19 SAFETY PRECAUTIONS WARNINGS - To reduce the risk of electrical shock, fire or injury: 1. Do not use the device if the power cable or plug is damaged. 2. Do not insert any sharp or pointed object through the ventilation holes of the device. 3. Do not let unauthorized personnel to play with the device. 4. Do not immerse the device in water, or allow water or any fluids to enter through the ventilation holes. 5. When removing the power plug, always hold the plug and never pull the cable. 6. Do not remove the power plug when your hands are wet. 7. Remove the power plug from the wall socket before cleaning the device. 8. Do not modify, disassemble or repair this device without proper training unless stated in the manual. 9. Do not replace the electric plug or cut the power cable. Replacing the plug or cutting the power cable in any way will immediately cause the Warranty to become void. Any subsequent fault in the operation of the device will not be covered by the Warranty, and repair and servicing will be chargeable. 10. If the power cable is damaged, contact an authorized Medklinn Service Centre for repairs immediately. 11. Do not attempt to open the inner compartment of the device. The device requires minimal maintenance, and no servicing or repairs are to be carried out by the User. Opening the device or tampering with it in any way will cause the Warranty to become void. If you encounter any problems with the device, please contact the nearest authorized Medklinn Service Centre. 12. Do not wipe the device with benzene or paint thinner. FOR FURTHER ASSISTANCE, PLEASE CALL OUR CUSTOMER SERVICE. 1. NOTE – Radio, TV or sensitive equipment interference: If the device should cause interference to radio, television reception or any sensitive equipment, try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the distance between the device and radio/TV receiver/sensitive equipment. - Connect the device into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. Cautions during operation: 1. Place the device at least 6 feet from radio, television or electronic equipment. This is to minimize the possibility of interference with the equipment or the remote controller. 2. Do not cover the device in any way at all, particularly the ventilation holes. Doing so will cause excessive heat build-up and may result in a fire and irreparable damage to the device. 3. Avoid placing the device where curtains or other furnishings may cover the ventilation holes. 4. Avoid placing the device in an oily environment as it may cause the module to be coated with a thicker layer of grease/debris. Hence, affecting its performance. 5. Ensure that there is free flow of air around the device. 6. Avoid locations where the device is exposed to condensation due to rapid and drastic temperature fluctuations. The device should only be used in temperatures between 5º-35ºC. 2. Device Identification Functional parts Filter Filters the air supply Service indicator Indicates time to service the device O2 control Controls the amount of oxygen flowing into the device’s ozone module ON/OFF button To switch the device ON/OFF Jetspray button Ozone water button To switch the ozone module ON/OFF Jetspray indicator Jetspray button Ozone water indicator To switch the jet spray mode ON/OFF Control panel Control/Monitors the entire system Side handle To ease moving and positioning the device Side handle Filter Service indicator Control panel Ozone water button ON/OFF button ON/OFF indicator O2 control Medklinn O3 Jetspray (Front View) 3. Device Identification Fan filter Ozone water outlet Jetspray water outlet Functional parts Fan filter: Filters dust from entering the fan and inner compartment Water inlet Water source flows into the inlet Ozone water outlet: Ozone water flows out from here to jet spray gun Jetspray water outlet: Supplied water flows out from here to jet spray gun Castor wheel: To ease in moving the device and allow the device to be stationary (lockable) Water inlet Castor wheel Medklinn O3 Jetspray (Left Side View) 4. Device Identification Functional parts Fan filter Fan filter: Filters dust from entering the fan and inner compartment Castor wheel: To ease in moving the device and allow the device to be stationary (lockable) Castor wheel Medklinn O3 Jetspray (Right Side View) 5. Device Identification Quick plug (Female) Hose To Jetspray gun Quick plug (Female) Hose 1(a) & (b) Hose 2 Medklinn O3 Accessories (Hose 1(a) – 1(b) & 2) Functional parts Quick plug (Female) Secures the hose to the water source and/or device Hose 1 Connects: 1(a). Water inlet to the device 1(b). Ozone water outlet and Jetspray gun Hose 2 Connects to Jetpray water outlet from the device to Jetpray gun water inlet 6. Device Identification Handle switch Ozone mixer Jetspray gun water inlet Ozone jetspray outlet Ozone jetspray gun inlet Functional parts Ozone jetspray gun inlet Ozone water flows through here from hose 2 Jetspray gun water inlet Jetspray water flows through here Handle switch To triggers the jetspray gun Ozone mixer Mixes the ozone water with jetspray water Ozone jetpray outlet Ozone jetspray water comes out here Jetspray gun 7. Optional Accessories Functional parts Hose reel Extension hose for the jetspray gun Hose reel 8. System Overview Medklinn O3 Jetspray converts supplied oxygen (O2) into ozone (O3) and infuses it into the water. • • • • The ozone water disinfects and deodorizes surfaces without hot water Eliminates bacteria viruses and mould Removes and prevents biofilm build-up Dissolves oil and grease When the Medklinn O3 Jetspray operates, the air is drawn into the device through the HEPA filter. This air is forced through a fine mesh filter that traps pollutants before passing into the oxygen tank, which separates the nitrogen from the air, resulting only oxygen is passed through. The concentrated oxygen is finally supplied to the ozone module which breaks it down to ozone (O3) with the use of electricity. It is then infused into the water through venturi injection to generate ozone water. The ozone water is finally delivered at a higher pressure and velocity with the jetspray gun. 9. Control Panel Identification Display screen Back Button Display screen: Displays information status of the device Back button: Works as a BACK button in the menus. Up button: To scroll up in the menus Down button: To scroll down in the menus Set button: To select options in the menus Up Down Set button button Button Control Panel 10. Fault Indicator Identification Ozone generator: Points to a problem with the ozone generator Oxygen chamber: Points to a problem with the oxygen chamber Air flow: Points to a problem with the air flow Alarm bypass: Shows that an alarm bypass was done and the device will continue running for another 30 days before shutting down NOTE: Follow the instruction displayed on the screen if any address fault occurred 11. Getting Started: Connecting the hose Using Quick Plug 1. Connect a Quick Plug (Male) to the water source pipe with male threaded end. Hose Quick Plug (Male) Quick Plug (Female) ¾” Pipe with male threaded end (water source) NOTE: Make sure that there is enough Teflon tape when attaching the Quick Plug (Male) to the threaded end of the pipe to avoid leakage at that point 12. 2. Pull the yellow cap of the Quick Plug (Female) while connecting to the Quick Plug (Male). Release the cap to secure the connection. There should be a “click” sound when the Quick Plugs are secured together. Pull the hose gently to confirm that the connection is indeed secured. 3. Connect the Quick Plug of hose 1(a) to the device’s Ozone Water Inlet. 4. Connect the Quick Plug of hose 1(b) to the device’s Ozone Water Outlet. 5. Connect pressurized hose from the jetspray gun to the device’s jetspray outlet and tighten the pipe with the threaded connector. Ozone Water Outlet to Ozone Jetspray gun Inlet Jetspray water Outlet to Jetspray gun water Inlet Water source (water tap) to Inlet device 13. 6. Attach the other end of the Ozone water quick plug (Female) from the device outlet to the jet spray gun (Male). From the Ozone water Outlet to Ozone Jetspray gun inlet 7. Attach the other end of the Jetspray outlet quick plug from the device to the jet spray gun and ensure that the bolt must be tighten tightly at jet spray gun side. Jetspray Outlet to Jetspray gun water inlet 14. To a water tap 1. If you have a water tap, please remove one end of the Hose 2 Quick Plug (Female) by loosening the cap. Hose 1(a) 2. Pull out the Quick Plug. 15. 3. Connect the hose to the water tap. Insert the hose clip to the hose before connecting to the water tap. Tighten the connection by using the hose clip with a screwdriver. Ensure it is tight and water will not leak out when the tap is turned on. Hose Clip 4. Connect the other Quick Plug (Female) of Hose 2 to the device’s Water Inlet. 5. Connect the Hose 1 Quick Plug (Female) to the device’s Water Outlet. Ozone water outlet to Jetspray gun Jetspray outlet to Jetspray gun Water source (water tap) to Inlet device 16. Getting Started: 1. 2. 3. 4. 5. 6. 7. 8. Turn on the device Plug the power inlet to the AC power outlet. Connect hoses provided to the device (Refer to Connecting the hose section). Turn on the water supply. Turn on the ON/OFF button. Turn on the Ozone button ON to produce active oxygen to the water. Turn on the jet spray button On to activate jet spray. Make sure that there are at least 5 secs before turning ON each switch. Make sure that the flow rate of the O2 Control is between 1- 1.5 lpm. Getting Started: Controlling the ozone level into the water The Medklinn O3 Jetspray ozone level is controlled by turning the knob of the O2 Control to increase or decrease the level ozone generation. It is advisable to keep the flow rate between 1 - 1.5 lpm. Knob Ball Bearing Before: O2 Control when device is at rest Turn Ball Bearing is floating After: O2 Control when device is in operation 17. Locking/unlocking the castor wheel 1. Make sure that the castor wheel is facing outward. Clipping Wheel 2. To lock the castor wheel, the clipping must be pressed downwards. Pressed clipping down to lock Pulled clipping up to unlock 3. To unlock the castor wheel, the clipping must be pulled upwards. 4. Do it for both wheels to lock/unlock it into position. 18. Basic Maintenance Cleaning the Fan Filter 1. Turn off the AC power outlet. Make sure the light at the ON/OFF Button is not lit. 2. Remove the Fan Filter at the right side by pulling out the Filter Cover. Fan Filter mesh Filter cover 19. 3. Brush the Filter Mesh with a soft bristle brush. Rinse and dry the Filter Cover. Wipe the Fan gently with a dry cloth. Filter Mesh Filter Cover 4. Assemble the Fan Filter in proper order and reattach it to the Fan. 5. Repeat the steps 1 to 4 for the other fan on the left. 6. Clean the Fan Filters once a month or when it is clogged up with dirt/dust which may block the Fans from functioning. (A clogged-up filter will damage the fan) 20. ">

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Ozone generation
- Jet spray function
- Water filtration
- On/Off controls
- Ozone level control
- Castor wheels
- Service indicator
- Quick plug connection
- Optional Accessories
- Alarm bypass
Frequently asked questions
Refer to the 'Connecting the hose' section in the manual for detailed instructions on connecting hoses to the device.
Clean the fan filters once a month or whenever they become clogged with dirt and dust.
The O2 control knob adjusts the ozone generation level. Keep the flow rate between 1-1.5 lpm for optimal performance.