Milli 2280916 is a diverter mixer that can be used in domestic, hotel, and commercial settings. It has a maximum continuous operating pressure of 500 kPa and a maximum continuous working temperature of 75°C. It is suitable for use with hot water storage tanks and continuous flow hot water systems. The mixer comes with a chrome finish and is easy to clean with soapy water or approved cleaners. It should not be cleaned with abrasive materials. The mixer must be installed by a qualified plumber in accordance with AS/NZS 3500.
advertisement
MILLI EDGE MK2
DIVERTER MIXER
60
5
58 - 75
ADJUSTMENT page 1 of 2
13
35
4
SPECIFICATIONS
Recommended Use
Finish Available
Pressure Rating
Temperature Rating
Suitable Hot Water
Standards
Domestic, hotel and commercial
Chrome
Maximum continuous operating pressure 500 kPa.
Note: For best performance and longer life, we recommend 150-500 kPa.
Maximum continuous working temperature 75 o C
Storage Tank: Yes
Continuous Flow: Refer to manufacturer of continuous hot water systems
Gravity Feed: No
AS/NZS 3718
CLEANING RECOMMENDATIONS
We recommend the use of soapy water or approved cleaners.
This product should not be cleaned with abrasive materials.
Damage caused by any improper treatment is not covered by the product warranty- refer to Warranty Conditions.
To see the complete MILLI EDGE range go to www.reece.com.au/bathrooms
AS/NZS 3718
WM-025901
Disclaimer: Products in this specification manual must by regulation be installed by licensed and registered trade people. The manufacturer/distributor reserves the right to vary specifications or delete models from their range without prior notification. Dimensions are nominal measurements only. Dimensions and set-outs listed are correct at time of publication however the manufacturer/distributor takes no responsibility for printing errors.
Tech Page Version 1
MILLI EDGE MK2
DIVERTER MIXER
page 2 of 2
INSTALLATION INSTRUCTIONS
Important Note
Mixer must be installed to the requirements of AS/NZS 3500 by a qualified plumber. Your mixer comes to you already factory assembled and tested. We do not recommend the dismantling of any internal part of the mixer. The mixers are factory tested and sealed so as to give the best performance.
53mm to 75mm
Adjustment
Screw the diverter mixer assembly in place. Attach water supplies.
Test and check for leaks
Do not remove Protective
Covers until final fit-off.
Cut a 40mm hole and a
45mm hole in cement sheet and tiles, 60mm apart, as shown.
40mm
INSTALLATION INSTRUCTIONS
DIVERTER MIXER
IN0288 REV B
CARTRIDGE REPLACEMENT
Removing Diverter: a) Unfasten and remove the Diverter Handle.
b) Pull the Dress Plate off the Mixer Assembly c) Unscrew and remove the Diverter Shroud with a 27mm tube spanner.
d) Unscrew and remove the Diverter Cartridge with a
21mm tube spanner.
Installing Diverter: a) Install the Diverter Cartridge with a 21mm tube spanner.
b) Install the Diverter Shroud with a 27mm tube spanner.
c) Push the Dress Plate back on the Mixer Assmebly d) Turn spindle Anti-Clockwise until it stops.
e) Fasten the Diverter Handle to the Diverter Cartridge.
Noggin
Cement sheet and Tiles
45mm
Hot
Inlet
Outlet 1
Outlet 2 recommended working pressure maximum hot water temperature
Cold
Inlet
Outlet 1
180°
Outlet 2
Remove the protective covers.
Gently push Dress Plate onto Mixer Assembly
Dress Plate
Attach Mixer Handle and Diverter Handle to Mixer Assembly.
Fasten Grub Screws firmly with Allen key supplied.
Insert Screw Caps and press firmly in place.
Grub Screw
Screw Plug
Mixer Handle
Grub Screw
Handle Screw Plug
NOTE:
- If the pressure exceeds or is likely to exceed 550kpa,
an approved pressure limiting device must be installed.
- Flush out all pipe work prior to installation.
- If the water temperature exceeds 75°C, an approved
tempering valve must be fitted.
- Installation should comply with Australian standard
AS3500.1 or relevant local authority requirements.
Showers may not be suitable for use within:
• Gravity-fed water systems
• Some instantaneous hot water systems; or
• Pressure supply less than 150kPa;
NOTE:The 500kPa maximum water supply pressure does not apply to fire service outlets.
Failure to comply with the above may void all warranties.
WARRANTY:
Please refer to the full warranty statement enclosed with the product before installing.
MAINTENANCE AND CARE:
- Products should be cleaned with mild
liquid detergent or soap and water.
- Do not use cream cleaners or citrus
based cleaning products, as they are
abrasive.
- Use of unsuitable cleaning agents may
damage the surface. Any damage caused
in this way will not be covered by
warranty.
DISCLAIMER:
While we aim to ensure the specifications shown are correct at the time of printing, we reserve the right to make modifications without prior notice. Always use the physical product measurements for mark-ups and roughing-in as the line drawing shown may differ from the actual product over time.
*All measurements are shown in millimeters.
Plumbers, please ensure a copy of the installation instructions is left with the end user for future reference