Care and Cleaning:
Never use abrasives or abrasive cleaning agents to clean this product. Clean regularly with contamination free warm soapy water and a damp soft cloth.
Periodically the filter washer should be removed from the end of the shower hose and cleaned.
WALL OUTLET BRACKET
Installation Guide
Technical Specifications:
Operating Pressure:
Min: 35kPa/0.35bar
Max: 500kPa/5.0bar*
Optimum: 150kPa/1.5bar - 500kPa/5bar
Operating Temperature:
Hot: Max 80°C*
Cold: Min 5°C
Inlet Connections:
All ½" BSP
* Regional specific regulations apply.
Please refer to your warranty statement at www.methven.com
Methven warrants this product against manufacturing defects and that it is suitable for use under the general operating conditions specified in this instruction sheet. However, regional regulations apply and may affect your warranty. Please refer to www.methven.com
or call customer service for full details.
New Zealand
0800 804 222
98-0277
Australia
1300 638 483
UK
0800 195 1602
ISSUE A
DECEMBER 2015 www.methven.com
•
•
IMPORTANT: Please read all of the instructions before installation.
General:
• Methven recommends this product is installed by a licensed plumber in compliance with all relevant regional regulations.
After installation all connections must be checked for leaks.
All outlets used primarily for personal hygiene shall deliver water at a safe temperature as per regional regulations.
• It is the responsibility of the installer to ensure a waterproof seal is achieved between the product and mounting surface. If in doubt about the quality of the seal, remove the product and reinstall using silicone to ensure a seal is achieved.
O-ring
Faceplate
Outlet Bracket
IMPORTANT: Before you begin, turn off the water supply.
•
•
Step 1
Wall lining hole should be cut or finished as per the dimension shown in the diagram on the right.
Cut off the threaded nipple 18±2mm from the wall lining and apply thread seal tape to ensure a good seal.
•
Step 2
Secure wall outlet bracket to the nipple by screwing until the sealing o-ring is tight against the wall lining.
2x Faceplate screws
½" BSP Nipple
(Not Supplied)
•
•
Step 3
Connect hose to outlet bracket and handset.
Ensure swivelling cone is connected to the handset.
Filter Washer
Non-Swivelling Cone
18±2mm
26mm max
Handset
Flat
Washer
Swivelling
Cone
Grub Screw