SATARaid GUI Manual

Add to my manuals
53 Pages

advertisement

SATARaid GUI Manual | Manualzz

SATARAID5™

Serial ATA

RAID5 Management Software

Home Edition

Users Manual

03/14/05

Silicon Image, Inc.

1060 East Arques Ave.

Sunnyvale CA 94085

(408) 616-4000 www.siliconimage.com

Copyright © 2004, Silicon Image, Inc. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated into any language or computer format, in any form or by any means without prior written permission of:

Silicon Image, Inc.

1060 East Arques Ave.

Sunnyvale CA 94085

Silicon Image, Inc. reserves the right to make changes to the product(s) or specifications to improve performance, reliability, or manufacturability. Information furnished is believed to be accurate and reliable, but Silicon Image, Inc. shall not be responsible for any errors that may appear in this document. Silicon Image, Inc. makes no commitment to update or keep current the information contained in this document.

However, no responsibility is assumed for its use; nor any infringement of patents or other rights of third parties, which may result from its use. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.

Silicon Image, Inc. products are not designed or intended for use in Life Support Systems. A Life Support System is a product or system intended to support or sustain life, which if it fails, can be reasonably expected to result in significant personal injury or death. If Buyer or any of its direct or indirect customers applies any product purchased or licensed from Silicon Image, Inc. to any such unauthorized use, Buyer shall indemnify and hold Silicon Image, Inc., its affiliates and their respective suppliers, harmless against all claims, costs, damages and expenses arising directly or indirectly, out of any such unintended or unauthorized use, even if such claims alleges that Silicon Image, Inc. or any other person or entity was negligent in designing or manufacturing the product.

Specifications are subject to change without notice.

SATARAID5 is a trademark of Silicon Image, Inc. JAVA is a trademark of Sun Microsystems, Inc. Windows is a trademark of

Microsoft Corp. for their family of computer operating systems.

Revision History:

Revision Comment Date

04/06/04

1.01 Updated for beta release. 04/30/04

1.02

1.03

1.04

1.05

1.06

1.07

Included “For SATARaid users” section.

Update chapter 6 based on BIOS changes.

Replaced some screen pictures with new ones to show the new product name.

Updated for release 1.2 which includes Port Multiplier support and Concatenation

05/07/04

06/17/04

Minor edits and clarifications 06/26/04

Update for new features for configuring SATARAID5. 06/30/04

07/01/04

03/14/05

2

Copyright © 2004 Silicon Image Inc. SATARAID5 User’s Manual

1 WELCOME 5

1.1

SATARAID5 F

EATURES

5

1.2

F

OR

SATAR

AID

U

SERS UPGRADING TO

SATAR

AID

5 5

1.2.1 RAID F

UNCTION

L

IST FOR

D

IFFERENT

V

ERSIONS OF

BIOS

AND

RAID D

RIVER

5

1.2.2 U

PGRADE

BIOS

AND

RAID D

RIVER

6

2 AN INTRODUCTION TO RAID 7

2.1 D

ISK

S

TRIPING

(RAID 0)

2.2 D

ISK

M

IRRORING

(RAID 1)

2.3 D

ISK

M

IRRORING AND

S

TRIPING

(RAID 10)

2.4 P

ARITY

RAID (RAID 5) 8

2.5 C

ONCATENATION

8

2.6 JBOD (J

UST

B

UNCH OF

D

ISKS

) 8

7

7

7

3 INSTALLING DRIVERS 9

4 JAVA 2 RUNTIME ENVIRONMENT INSTALLATION

5 SATARAID5 GUI INSTALLATION

6 CREATING AND DELETING LEGACY RAID GROUPS WITH BIOS UTILITY 13

6.1

C

REATING

RAID G

ROUPS

15

6.2

C

REATING

S

PARE

D

RIVE

16

6.3

C

REATING

JBOD 16

6.4

D

ELETING

RAID G

ROUPS

, S

PARE

D

RIVE

,

AND

JBOD 17

6.5

R

EBUILD

RAID 1 S

ET

6.6

R

ESOLVING

C

ONFLICTS

18

19

6.7

L

OW

L

EVEL

F

ORMATTING

21

6.8

L

OGICAL

D

RIVE

I

NFORMATION

21

6.9

R

ESERVED

D

RIVE AND

S

ETTING

S

IZE FOR

RAID S

ET

, S

PARE

D

RIVE

,

OR

JBOD 21

7 ALLOCATING PARTITIONS IN WINDOWS 23

7.1

W

INDOWS

S

ERVER

2003 & XP & 2000 23

7.1.1

C

REATING THE

P

ARTITIONS

24

8 SATARAID5 GUI OVERVIEW

SATARaid5 User’s Manual Copyright © 2004 Silicon Image Inc.

28

3

10

12

8.1

RAID G

ROUPS AND

D

EVICE

C

ONFIGURATION

W

INDOWS

28

8.2

SATARAID5 M

ENU

C

OMMANDS

29

8.2.1

C

ONFIGURATION

8.2.2

E

XIT

30

34

8.2.3

C

REATE

S

PARE

8.2.4

D

ELETE

S

PARE

8.2.5

D

ELETE

M

EMBER

8.2.6

D

ELETE

O

RPHAN

35

35

36

36

8.2.7

D

EVICE

S

UMMARY

8.2.8

C

REATE

RAID G

ROUP

37

38

8.2.9

R

EBUILD

RAID G

ROUP

40

8.2.10

D

ELETE

RAID G

ROUP

40

8.2.11

RAID G

ROUP

S

UMMARY

41

8.2.12

T

ASK

M

ANAGER

8.2.13

E

VENT

L

OG

43

47

8.2.14

R

ESOURCES

49

8.2.15

C

REATE

L

EGACY

RAID G

ROUP

49

8.2.16

R

EBUILD

L

EGACY

RAID G

ROUP

50

8.2.17

D

ELETE

L

EGACY

RAID G

ROUP

50

8.2.18

C

ONVERT

L

EGACY

RAID G

ROUP

51

8.2.19

C

REATE

L

EGACY

S

PARE

51

8.2.20

D

ELETE

L

EGACY

S

PARE

52

8.2.21

C

ONVERT

L

EGACY

S

PARE

52

8.2.22

H

ELP

T

OPICS

8.2.23

A

BOUT

53

53

4

Copyright © 2004 Silicon Image Inc. SATARAID5 User’s Manual

1 Welcome

Silicon Image’s SATARAID5

TM

software provides Serial ATA RAID 0 (Striping), RAID 1 (Mirroring), RAID 5 (Parity RAID),

RAID 10 (Striping and Mirroring), and JBOD (just a bunch of disks) functionality to enhance the industry’s leading PCI-to-SATA host controller products. Two major challenges facing the storage industry today are keeping pace with the increasing performance demands of computer systems by improving disk I/O throughput and providing data accessibility in the face of hard disk failures while utilizing full disk capacity. With SiIicon Image Serial ATA host controller and SATARAID5, both of these problems are solved.

SATARAID5 software provides a Graphical User Interface (GUI) for easy-to-use configurations of the RAID Groups.

1.1 SATARAID5 Features

RAID 0, RAID 1, RAID 5, RAID 10, Concatenated and JBOD Groups are supported.

Supported OS: Win2000/XP/Server 2003.

SATA-II Port Multiplier support.

RAID Groups can be created and deleted without exiting Windows.

Hot Spare and On-line Rebuilding. The spare policy supports testing periodically for a health check of the spare disk.

Spare drive can be global or dedicated to a specific RAID group.

Supports Auto and Manual rebuild policy for a RAID group.

System GUI Monitoring Utility:

Displays/Logs/Alerts Users to Vital RAID Group Information.

Manages RAID Group Functions (configures, rebuilds, etc.,).

Supports the ability to partition and map a segment of disk to a virtual LUN or disk.

Supports up to two RAID groups. Any excess capacity on disk drives can be formatted as independent logical drives.

Adjustable Stripe Size for RAID 0, RAID 5, and RAID 10.

Uses the Self-Monitoring, Analysis, and Reporting Technology (SMART) feature in the attached drives for automatic notification of imminent drive failures.

Employ RAID recovery algorithms to maintain data integrity in the event of a disk failure including bad block management.

Automatically Selects Highest Available Transfer Speed for All SATA Devices. Supports the following:

Data transfer rate up to 150MB/Sec (SiI3114, SiI3124-1), and 300MB/Sec (SiI3124-2, Sil3132)

Support up to 4 SATA devices connected to a single controller.

ACPI, SATA 1.0 (SiI3114, Sii3124-1), and SATA 2.0 (SiI3124-2, Sil3132)

Supports drive roaming capability allowing drives from one controller to be moved to another without loss of data.

Employs a task manager for the scheduling of any RAID or disk management operations including RAID group creation, rebuild, and test.

1.2 For SATARaid Users upgrading to SATARaid5

If you plan to upgrade to RAID 5 driver and/or BIOS from previous drivers without RAID 5 capability, read this section carefully before upgrading BIOS and/or RAID driver. Otherwise, you might get unexpected results.

We do not recommend downgrading from RAID 5 driver to the previous (non-RAID 5) RAID driver.

1.2.1 RAID Function List for Different Versions of BIOS and RAID Driver

The following list shows possible BIOS and RAID driver combination and RAID functions supported by each combination.

(Legacy RAID group is a RAID set that is compatible with older SiI3112A, SiI3114, and SiI3124 SATARaid software drivers).

1. Old BIOS with Old RAID Driver

Non-RAID Hard Disk

Legacy RAID 0 group

Legacy RAID 1 group

Legacy RAID 10 group

Legacy spare drive

2. Old BIOS with New RAID Driver

Legacy RAID 0 group

Legacy RAID 1 group

Legacy RAID 10 group

SATARaid5 User’s Manual Copyright © 2004 Silicon Image Inc.

5

Legacy spare drive

New RAID 0 group (BIOS will not recognize this)

New RAID 1 group (BIOS will not recognize this)

New RAID 5 group (BIOS will not recognize this)

New RAID 10 group (BIOS will not recognize this)

New spare drive (BIOS will not recognize this)

JBOD (BIOS will not recognize this)

3. RAID 5 BIOS with Old RAID Driver

Legacy RAID 0 group

Legacy RAID 1 group

Legacy RAID 10 group

Legacy spare drive

4. RAID 5 BIOS with New RAID Driver

Legacy RAID 0 group

Legacy RAID 1 group

Legacy RAID 10 group

Legacy spare drive

New RAID 0 group

New RAID 1 group

New RAID 5 group

New RAID 10 group

New spare drive

JBOD

1.2.2 Upgrade BIOS and RAID Driver

If you upgrade from old BIOS and old RAID driver to a newer version of BIOS and/or RAID drive, you may lose some functions.

Also, the new driver may not recognize non-RAID drives. If you are upgrading the software driver from the previous non-

RAID 5 versions, the following is a list of precautions users should realize before upgrading BIOS and RAID driver to a newer version.

1. If you’re upgrading to RAID 5 driver only:

If the boot drive is a non-RAID drive, the system will not boot.

No non-RAID drive support.

When creating RAID groups through GUI, only those RAID groups created in legacy mode will be recognized by BIOS.

The existing RAID 0 or RAID 10 groups (created with previous version of BIOS or GUI) with 4 KB stripe size will not work.

2. If you’re upgrading to RAID 5 BIOS only:

If the boot drive is a non-RAID drive, the system will not boot.

No non-RAID drive support.

RAID driver will not recognize JBOD and RAID 5 group created by BIOS.

3. If you’re upgrading to RAID 5 BIOS and RAID 5 driver

If the boot drive is a non-RAID drive, the system will not boot.

No non-RAID drive support.

The existing RAID 0 or RAID 10 groups (created with previous version of BIOS or GUI) with 4 KB strip size will not work.

6

Copyright © 2004 Silicon Image Inc. SATARAID5 User’s Manual

2 An Introduction to RAID

RAID - Redundant Array of Independent Disks

RAID technology manages multiple disk drives to enhance I/O performance and provide redundancy in order to withstand the failure of any individual member, without the loss of data. There are many different methods of implementation for RAID, with each having advantages and disadvantages. Raid levels or set types are given a numerical designator that defines its implementation such as RAID 0 or RAID 1. SATARAID5 provides support for three RAID Group types: Striped (RAID 0),

Mirrored (RAID 1), and RAID 10 Mirrored/Striped. Other RAID types are not supported by SATARAID5 software and thus are not discussed.

2.1 Disk Striping (RAID 0)

Striping is a performance-oriented, non-redundant data mapping technique. While Striping is discussed as a RAID Group type, it is does not provide any fault tolerance. With modern SATA and ATA bus mastering technology, multiple I/O operations can be performed in parallel, enhancing data throughput. Striping arrays use multiple disks to form a larger virtual disk. The figure below illustrates a three-disk stripe set. Stripe one is written to disk one, stripe two to disk two, and so forth. RAID 0 sets can be comprised of two, three, or four drives.

Stripe0

Stripe3

Stripe6

Stripe9

Stripe1

Stripe4

Stripe7

Stripe10

Stripe2

Stripe5

Stripe8

Stripe11

2.2 Disk Mirroring (RAID 1)

Disk mirroring creates an identical twin for a selected disk by having the data simultaneously written to two disks. This redundancy provides instantaneous protection from a single disk failure. If a read failure occurs on one drive, the system reads the data from the other drive. RAID 1 sets are comprised of two drives. A third drive can be allocated as a spare in case one of the drives in the set fails.

Block 0

Block 1

Block 2

Block 3

Block 0

Block 1

Block 2

Block 3

2.3 Disk Mirroring and Striping (RAID 10)

RAID 10 combines the features of both RAID 0 and RAID 1. Performance is provided through the use of Striping (RAID 0), while adding the fault tolerance of Mirroring (RAID 1). The implementation of RAID 10 requires four drives. The drives are assigned as two sets of striped pairs.

The data is written to RAID Group A, which is striped (RAID 0). This allows maximum speed. The data is then mirrored to another RAID 0 striped set, which is Set B in the figure above. This provides data redundancy (RAID 1), and thus increased data security.

SATARaid5 User’s Manual Copyright © 2004 Silicon Image Inc.

7

Under certain circumstances, a RAID 10 set can sustain multiple simultaneous drive failures.

2.4 Parity RAID (RAID 5)

Parity or RAID 5 adds fault tolerance to Disk Striping by including parity information with the data. Parity RAID dedicates the equivalent of one disk for storing parity stripes. The data and parity information is arranged on the disk array so that parity is written to different disks. There are at least 3 members to a Parity RAID set. The following example illustrates how the parity is rotated from disk to disk.

Parity RAID uses less capacity for protection and is the preferred method to reduce the cost per megabyte for larger installations. Mirroring requires 100% increase in capacity to protect the data whereas the above example only requires a 50% increase. The required capacity decreases as the number of disks in the group increases.

2.5 Concatenation

Concatenation combines multiple disks or segments of disks into a single large volume. It does not provide any data protection or performance improvement but can be useful for utilizing left over space on disks. Concatenation allows the segments which make up the volume to be of difference sizes.

2.6 JBOD (Just Bunch of Disks)

The JBOD is a virtual disk that can either be an entire disk drive or a segment of a single disk drive. For home edition, JBOD function only supports one disk.

8

Copyright © 2004 Silicon Image Inc. SATARAID5 User’s Manual

3 Installing Drivers

Before installing the SATARAID5 software, Silicon Image Serial ATA host adapter driver must be installed. When Windows detects the newly installed SATA host adapter, it will open a Driver Installation Wizard. Click on the Next buttons until the wizard prompts for the location of the driver. Insert the Silicon Image SATA host adapter driver CD into the computer’s CD-

ROM drive and click on the Browse button. Select the directory on the CD in which the driver resides and click OK.

Click the Next button. A window will be displayed to verify proper installation of the host adapter driver. Click Finish. When prompted to restart the computer, click Yes.

SATARaid5 User’s Manual Copyright © 2004 Silicon Image Inc.

9

4 JAVA 2 Runtime Environment Installation

The Java 2 Runtime Environment is required for the SATARAID5 GUI. The Java 2 Runtime Installer and executable package must be downloaded from the Sun Microsystems website at http://java.sun.com/j2se/downloads.html. The computer must have an Internet connection set up before installation can proceed.

Save the installer file to a known location, such as the My Documents folder. Using Windows Explorer or by clicking on the My

Computer icon on the desktop, select the installation file and open it. The installation will begin. The installer program will download the needed files from the Internet.

When a window appears asking for acceptance the license agreement, select I accept the terms of this license agreement and click Next.

10

Copyright © 2004 Silicon Image Inc. SATARAID5 User’s Manual

Choose the Typical setup type and click Next.

When the installation completes, click Finish. Restart the computer when prompted.

SATARaid5 User’s Manual Copyright © 2004 Silicon Image Inc.

11

5 SATARAID5 GUI Installation

Insert the Silicon Image SATARAID5 Installation CD into the computer’s CD-ROM drive. Using Windows Explorer or by clicking on the My Computer icon on the desktop, display the contents of the CD-ROM. The SATARAID5 GUI Installation program is named SATARAID5.exe. Select this file and open it. The installation will begin.

Click the Next button when the Welcome window appears.

Click the Next button to install the SATARAID5 program in the default directory (recommended). An alternate directory may be selected if desired.

After installation is done, click the Finish button to complete the installation.

Copyright © 2004 Silicon Image Inc.

12

SATARAID5 User’s Manual

6 Creating and Deleting Legacy RAID Groups with BIOS

Utility

Legacy RAID sets and JBOD can be created and managed by either the BIOS utility or the SATARAID5 GUI. New RAID

groups must be created and managed by the SATARAID5 GUI. See section 8 SATARAID5 GUI Overview for information on

configuring RAID Groups using the SATARAID5 GUI.

During boot up, a screen similar to that below will appear for about 5 seconds. Press CTRL+S or the F4 key to enter the BIOS

RAID utility.

The RAID Utility menu screen will be displayed. A brief description of each section is presented on the next page.

SATARaid5 User’s Manual Copyright © 2004 Silicon Image Inc.

13

Main Menu

The Main Menu in the upper left corner is used to choose the operation to be performed. The selections are:

Create RAID Group

Delete RAID Group

Rebuild RAID 1 Set

Resolve Conflicts

Low Level Format

Logical Drive Info

Create RAID Group is used to create a new legacy RAID Set or for allocating legacy spare drives.

Delete RAID Group is used to delete a legacy RAID Set or to deallocate a legacy spare drive.

Rebuild RAID 1 Set is used to initiate the rebuild of a RAID 1 set after, for example, a drive in the Group has been replaced.

Resolve Conflicts is used to automatically find the member drives of a RAID set which has been disrupted (physical drives swapped around, for example) and restore the Set to proper operation.

Low Level Format allows a single drive to have its data completely wiped out. Drives assigned to Sets or allocated as spares cannot be low level formatted.

Logical Drive Info shows the current configuration of each RAID set, allocated spare, and unallocated physical drive attached to the SATA host adapter.

These operations are detailed in the pages that follow.

Help Window

This window displays context-sensitive help and status messages.

Physical Drive Information

This window displays the model number and capacities of the drives physically attached to the SATA host adapter.

Logical Drive Information

This window displays all logical drives connected to the controller. The upper part lists RAID sets and JBOD drives reported to the system BIOS. The lower part lists spare drives, reserved drives, conflict drives, and invalid drives not reported to the system BIOS.

Command Line

The bottom line of the display lists the currently active command keys:

Up and Down arrows select the menu item or action

ESC takes the user to the previous menu

Enter selects the highlighted choice

Ctrl-E exits the utility

Other keys may be active depending upon the currently selected action.

14

Copyright © 2004 Silicon Image Inc. SATARAID5 User’s Manual

6.1 Creating RAID Groups

As previously discussed, the Silicon Image SATA host adapter supports RAID 0, 1, 5, 10, and JBOD configurations. The selection of the RAID level to be used should be based upon factors including performance, data security, and number of drives available. It is best to carefully consider the long-term role of the system and plan the data storage strategy appropriately.

Silicon Image has made the creation of RAID sets very simple. They can be created either automatically or to allow the greatest flexibility, manually.

1. Select “Create RAID set”

2. Choose a RAID 0 Striped, a RAID 1 Mirrored, a RAID 5 Parity, or a RAID 10 combination set.

3. Select Automatically or Manually configuration of the RAID Set.

SATARaid5 User’s Manual Copyright © 2004 Silicon Image Inc.

15

4. If manual configuration is selected, the chunk size of Striped Sets can be selected. For Mirrored Sets, the Source and

Target drives can be selected.

5. If auto configuration is selected, BIOS will select RAID member drives automatically and the chunk size of Striped Sets is set to 64KB.

6. Select RAID set size with

↑ and ↓ keys. See section 6.9 for explanation on selecting size.

7. After the RAID set size is set, the message “Are You Sure?” will display before completing the configuration. Answer “N” to abort the creation of the new RAID set, or “Y” to proceed with the RAID set creation.

8. RAID sets can be created in both BIOS and in the SATARaid5 GUI. If you have excess capacity left on your hard drives after creating a RAID set in the BIOS, you can later go to the SATARaid5 GUI to create additional logical drives that fully utilize the capacity on all your hard drives.

6.2 Creating Spare Drive

If there is a RAID 1 set, spare driver can be created. The spare drive can be allocated to the RAID 1 set in the event of a failure of one of the drives in the RAID 1 set.

1. To create a spare drive for RAID 1 set, Select “Create RAID set”

2. Select “Spare Drive” and press Enter.

3. Select spare drive from the physical drive list and press Enter.

4. Select spare drive size with

↑ and ↓ keys. See section 6.9 for explanation on selecting size.

5. After the spare drive size is set, the message “Are You Sure?” will display before completing the configuration. Answer

“N” to abort the creation of the spare drive, or “Y” to proceed with the spare drive creation.

6.3 Creating JBOD

Since BIOS no longer reports non-RAID drives to the system BIOS, if a non-RAID boot drive or data drive is desired, a JBOD can be created so BIOS will report it to the system BIOS.

1. To create a JBOD, Select ”Create RAID set”

Copyright © 2004 Silicon Image Inc. SATARAID5 User’s Manual

16

2. Select “JBOD” and press Enter.

3. Select JBOD drive from the physical drive list and press Enter.

4. Select JBOD size with

↑ and ↓ keys. See section 6.9 for explanation on selecting size.

5. After the JBOD size is set, the message “Are You Sure?” will display before completing the configuration. Answer “N” to abort the creation of the JBOD, or “Y” to proceed with the JBOD creation.

6.4 Deleting RAID Groups, Spare Drive, and JBOD

1. To remove one or more RAID sets, spare drives, and JBODs, select “Delete RAID set”

2. Select the desired item to delete from the logical drive list and press Enter.

3. Press “Y” when asked, “Are You Sure?”

4. The drives will be returned to the selection of logical drives from which a new RAID set can be created.

SATARaid5 User’s Manual Copyright © 2004 Silicon Image Inc.

17

6.5 Rebuild RAID 1 Set

This menu selection is used to initiate the copying of data from an existing drive to a replacement drive that has been installed in a RAID 1 set after the failure of one of the members.

1. Select “Rebuild RAID 1 set”

2. Select the desired set and press Enter.

3. Press “Y” when asked, “Are You Sure?”

4. The set will be rebuilt. The status of the rebuild is displayed in the MAIN MENU window.

18

Copyright © 2004 Silicon Image Inc. SATARAID5 User’s Manual

6.6 Resolving Conflicts

When a RAID set is created, the metadata written to the disk includes drive connection information including the channel on the host adapter to which it is connected. If after a disk failure the replacement disk was previously part of a RAID set or used in another system, it may have conflicting metadata, specifically in reference to the drive connection information. If so, this will prohibit the RAID set from being either created or rebuilt. In order for the RAID set to function properly, this old metadata must be first overwritten with the new metadata. To correct this, select “Resolve Conflict” and the correct metadata, including the correct drive connection information; will automatically be written to the replacement disk.

1. Select “Resolve Conflicts” and press Enter.

2. Select the “Conflict” entry in the Logical Drive Status window and press Enter.

SATARaid5 User’s Manual Copyright © 2004 Silicon Image Inc.

19

3. Note that some conflict resolutions may result in the drive letter assignment changing; for example the RAID set may have been drive D: but after the conflict resolution, it may become drive E. Be aware of this when performing a conflict resolution. To maintain the same drive lettering, the SATA cables connected to the drives may need to be swapped, or in the case of a SATA-based removable drive unit, the order of the drives within the chassis made need to be changed.

Press ‘Y’ to accept the change and resolve the conflict.

4. The conflict will be resolved. The RAID Set will appear in the Logical Drive window.

20

Copyright © 2004 Silicon Image Inc. SATARAID5 User’s Manual

6.7 Low Level Formatting

The Low Level Format menu selection allows the complete erasure of data on a hard drive. This is not an action, which typically needs to be performed as formatting the drive under Windows is usually sufficient to prepare the drive for use.

6.8 Logical Drive Information

This menu item allows the display of the assignment of physical drives within a logical set (RAID set, RAID 1 spare, or unassigned). It is a display-only function. Use the up and down arrow keys to scroll between the drives in the Logical Drive

Properties window. Press the ESC key when done viewing logical drive information.

6.9 Reserved Drive and Setting Size for RAID Set, Spare Drive, or JBOD

Once a physical drive has been used to create a RAID set, spare drive, or JBOD by BIOS utility, BIOS saves user selected set or drive size in the reserved area of the physical drive. There is no way to remove the reserved area information even after the user deletes the set or drive. For this reason, after a set or drive is deleted, BIOS recognizes the physical drive as a reserved logical drive and it will not report the drive to the system BIOS.

When user selects to create a RAID set, spare drive, or JBOD, he or she has to select size for the set or drive. BIOS will set a default size for it and user can use the

↑ and ↓ keys to change the size. If the physical drive has never been used to create a

SATARaid5 User’s Manual Copyright © 2004 Silicon Image Inc.

21

set or drive by the BIOS before, the full size of the physical drive will be set as default size. Otherwise, BIOS will set default size to the size it saved in the reserved area of the physical drive before.

If the user wants to increase the default size, BIOS will display a warning message in the help window and for user’s response before changing the default size.

22

Copyright © 2004 Silicon Image Inc. SATARAID5 User’s Manual

7 Allocating Partitions in Windows

After the Raid groups have been created either using BIOS RAID utility or SATARAID5 GUI, the Raid group must have a partition defined on it, then the Raid group must be formatted in preparation for use under Windows.

Windows XP, 2000, and Server 2003 use the Disk Management utility that is part of the Operating System. There are enough nuances that make it important to follow the procedure specific to the Operating System.

7.1 Windows Server 2003 & XP & 2000

Before creating any partitions, RAID groups must first be created using the BIOS RAID Utility or the SATARAID5 GUI. Once the sets have been created, allow the system to load Windows. Once Windows is running, open the Disk Management window located at:

Control Panel> Administrative Tools> Computer Management> Storage> Disk Management

A window similar to the following should appear:

This window has three main sections:

1) System listing of all formatted and available disks/RAID Groups.

2) Report of physical connection of disks/RAID Groups.

3) Report of partition status, disk letter, and volume name.

In the physical connection window, every disk should report as:

Basic

Disk Size (the actual available disk space will be reported here)

Online

Instead of “Basic,” a disk may also report as either “Unknown” or “Dynamic.” If the disk reports as “Unknown” right-click on the disk icon and click “Write Signature.” A window will appear with the disk in question (all “Unknown” disks may appear in this window). Make sure the box next to each disk is checked, and then click OK. The disk should now report as “Basic.”

SATARaid5 User’s Manual Copyright © 2004 Silicon Image Inc.

23

If a disk reports as “Dynamic,” right-click on the icon of that disk, and click on “Revert to Basic Disk...” Within seconds the disk should report as Basic.

7.1.1 Creating the Partitions

In the Report of physical connection of disks/RAID Groups section, the order in which the drives are displayed corresponds directly to the order the Sets appear in the BIOS. Therefore, the first Unallocated Partition represents Set 1, and so on.

1. In this example, there are two disks with unallocated partitions. Right-click on the partition of the first disk and click on

“Create Partition...”

2. The “Create Partition Wizard” should appear. The first window is an introductory window to the Wizard. Click Next.

3. The second window designates the partition type. Choose primary partition and click Next.

4. The third window designates the partition size. Since this is a Striped RAID set utilizing 2 disk drives, the size of the partition will be approximately twice the size of the smallest single disk drive. Click Next.

Copyright © 2004 Silicon Image Inc. SATARAID5 User’s Manual

24

5. The fourth window designates the drive letter of the partition. Change the drive letter if desired. Click Next.

SATARaid5 User’s Manual Copyright © 2004 Silicon Image Inc.

25

6. The next window allows the volume label to be set and selection of the type of formatting to take place upon the creation of the partition. Make sure the Format this partition. . .” radio button is selected. Name the volume as desired

(suggestions are generic names such as STRIPED SET or something specific to use such as FINANCIAL, CRITICAL,

MISCELLANEOUS, etc.). It is recommended to use the default NTFS for the file system. Click Next.

7. The last window is a summary window listing all of the selections made. After verifying that everything is correct, click

Finish.

26

Copyright © 2004 Silicon Image Inc. SATARAID5 User’s Manual

The status of the newly created partition in the Disk Management window should change to Formatting and the percentage complete will be displayed. Depending upon the size of the partition, the format process may take several minutes. When complete, the status will change to “Healthy” and the name and drive letter will be updated. Once the disk reports Healthy, it appears in the listing in System Listing section with all of its pertinent information as well.

Repeat the above procedure as needed for any other partitions. Close the Data Management window by clicking on the small boxed “X” in the top right corner of the window. Click on the “My Computer” icon on the Desktop. The new drives will be visible and properly named. The new disks are available for use.

SATARaid5 User’s Manual Copyright © 2004 Silicon Image Inc.

27

8 SATARAID5 GUI Overview

The SATARAID5 GUI Installation program configures the SATARAID5 GUI to automatically start when Windows is started. If the SATARAID5 GUI does not automatically start or is closed by the user, choose the SATARAID5 program from the Start

Menu to launch the GUI.

The SATARAID5 GUI monitors the system’s RAID Group. The main window will display:

8.1 RAID Groups and Device Configuration Windows

The RAID Groups window identifies SATA host adapters and configured RAID groups. Selecting each RAID group in the RAID

Groups window, members consisting of the RAID group will be highlighted in the Device Configuration window.

Right clicking on each node in the RAID Group window, a popup menu will be displayed to let user select action to be performed for the selected controller or RAID group.

The Device Configuration window identifies all physical drives and their partitions. If the adapter is connected to a Port

Multiplier, there may be more than one device ID per channel. A physical drive can be partitioned to several portions and each portion can be a RAID group member, a spare drive, or a virtual drive.

28

Copyright © 2004 Silicon Image Inc. SATARAID5 User’s Manual

8.2 SATARAID5 Menu Commands

The Main menu commands are shown below

Configuration

Exit

Create Spare Create RAID

Group

Delete Spare Rebuild RAID

Group

Support

Task Manager Create Legacy

RAID Group

Event Log Rebuild

Legacy RAID

Group

Help Topics

About

Member Group

Delete Orphan RAID Group

Summary

RAID Group

Convert

Legacy RAID

Group

Spare Summary

Spare

Convert

Legacy Spare

The commands are documented on the pages that follow.

SATARaid5 User’s Manual Copyright © 2004 Silicon Image Inc.

29

8.2.1 Configuration

SATARAID5 configuration options include customization of the settings for Log File, Popup, and Advanced Options. This command displays a dialog box to let user set different configurations for SATARAID5 with the following three tabs:

Log File Tab

The log file is used to store event information received from all Silicon Image RAID drivers. The log file is a text file and can be viewed with any text viewer (such as Notepad) or with the Event Log window of SATARAID5. Use the Log File tab to set location and the desired filename for the log file.

30

Copyright © 2004 Silicon Image Inc. SATARAID5 User’s Manual

Popup Tab

SATARAID5 can be configured to notify the user of events using messages in popup windows. Use the slider control to set the event level for popups to occur:

- Error Level - The following events will trigger a popup window:

Errors

- Warning Level - The following events will trigger a popup window:

Warnings

Errors

- Information Level - The following events will trigger a popup window:

Informational

Warnings

Errors

- Disable All - No events will trigger a popup window.

SATARaid5 User’s Manual Copyright © 2004 Silicon Image Inc.

31

Advanced Options

The Advanced Options tab is used to control advanced features of the RAID driver. By default, all these advanced options are disabled.

The following features are supported:

1. Legacy (Bootable) Support – When this feature is selected, Legacy Support menu will be available in the menu bar. The

Legacy Support Menu includes a list of menu items to support RAID functions for legacy RAID groups. For detailed

Legacy Support features, refer to sections from 8.2.15 Create Legacy RAID Group to 8.2.21

Convert Legacy Spare.

2. Delete Member Support – When this feature is selected, Delete Member menu item will be available under the Device menu. The Delete Member menu item allows the user to delete a member from RAID 1 (Mirroring), RAID 5 (Parity RAID),

and RAID 10 (Striping and Mirroring) groups. For detailed Delete Member feature, refer to section 8.2.5 Delete

Member.

3. Advanced RAID Features – When this feature is selected and user selects to create RAID group, if the RAID group to be created is fault tolerance group (RAID 1, RAID 5, or RAID 10), user will be able to select Improper Shutdown Policy in the

Create RAID Group dialog box. The Advanced RAID Features are not supported for Legacy RAID groups.

32

Copyright © 2004 Silicon Image Inc. SATARAID5 User’s Manual

4. Resources Info Support – When this feature is selected, Resources menu item will be available under the Window menu.

This feature is for debugging purpose only. For detailed Resources feature, refer to section

SATARaid5 User’s Manual Copyright © 2004 Silicon Image Inc.

33

8.2.14 Resources.

8.2.2 Exit

This command terminates the SATARAID5 program.

34

Copyright © 2004 Silicon Image Inc. SATARAID5 User’s Manual

8.2.3 Create Spare

This command displays a dialog box to let user create Spare Drive, user needs to select the following parameters:

Spare Type: Global -- the spare drive is for all RAID groups in the system.

RAID Group: Select the RAID group to which this spare drive is dedicated. This parameter is enabled only when

Dedicated spare type is selected.

Capacity: Select from a list of spare drive size, current options are from 128 MB to 100 GB and MAX.

Device: Select one device segment from the available device segment list

8.2.4 Delete Spare

This command displays a dialog box to let user choose one or more Spare Drives to delete.

SATARaid5 User’s Manual Copyright © 2004 Silicon Image Inc.

35

8.2.5 Delete Member

This command displays a dialog box to let user choose RAID groups’ members to delete. Since RAID 0 is not fault-tolerant,

RAID 0 members will not be shown in the list.

Note: delete RAID group member will reduce the RAID group to be a non-fault-tolerant RAID group.

8.2.6 Delete Orphan

An orphan device segment is part of a RAID group that cannot access another device segment within the same RAID group.

When a member of a RAID group fails in a sever manner (such as a loss of power or a complete hard disk failure), it becomes an orphan.

This command displays the Delete Orphan Segment window to show all orphan segments and allow user to delete selected orphan segments.

36

Copyright © 2004 Silicon Image Inc. SATARAID5 User’s Manual

8.2.7 Device Summary

This command displays the Segment Summary window to show all physical devices’ segments.

The Segment Summary window has it’s own menu bar. All options available via the menu bar are shown below

File Options

Exit Sorting…

Fields…

Exit

This command closes the Task Summary window.

Sorting

This command sorts the rows based on the selected field.

SATARaid5 User’s Manual Copyright © 2004 Silicon Image Inc.

37

Fields

This command displays a dialog box to let user choose which fields will be shown in the Segment Summary window.

8.2.8 Create RAID Group

This command displays a dialog box to let user create RAID group, user needs to specify the following parameters:

RAID Group Label: Provide a name for the RAID group

RAID Group: Select a group ID from the available ID list. Since the maximum number of RAID groups is limited to 8 so group ID can be from 0 to 7.

Capacity:

Chunk Size

Rebuild Priority:

Select from a list of RAID group size, current options are from 256 MB to 100 GB, and MAX. Selecting

MAX will create the largest RAID set possible with the drive(s) selected.

Select one from the available list: 8, 16, 32, 64, 128 (KB). RAID 1 set and virtual disk do not require this.

Chunk size is also known as stripe size.

Select one from the available list: 1 to 10. RAID 0 set and virtual disk do not require this. 10 is a higher level of rebuild priority which means that rebuild times will be faster but will take more CPU resources in order to rebuild a failed RAID member. In contrast, selecting 1 will result in slower rebuild times but will take the least amount of CPU resources to complete a rebuild.

After parameters are set, click on the Create button on the bottom to create the RAID array. The array will appear in the

Device Configuration Window of the SATARaid5 GUI.

If no other RAID sets are to be created, then click Cancel to exit the RAID creation window.

Go to the Disk Management Utility in Windows to initialize and format the newly created RAID set. Please refer to Chapter 7

Allocating Partitions in Windows for instructions on initialization and formatting.

38

Copyright © 2004 Silicon Image Inc. SATARAID5 User’s Manual

In Example 1, a RAID 0 (striped) array called Volume A – RAID Group 0 with capcity of 2GB with 32KB chunk size (stripe size) with rebuild priority 10 is created over hard drive 0 and 1

In Example 2, a RAID 10 (mirrored striped) array called Volume A- RAID Group 0 with capcity of 2GB with 32KB chunk size

(stripe size) with rebuild priority of 8 is created over hard drive 0,1,2, and 3.

For concatenated RAID Groups, a second dialog box will appear allowing the user to select the individual segment sizes from each disk. This is necessary since the segments of a concatenated RAID group may be of different sizes.

SATARaid5 User’s Manual Copyright © 2004 Silicon Image Inc.

39

8.2.9 Rebuild RAID Group

This command displays a dialog box to let user choose a replacement segment to rebuild a non-fault tolerant RAID group.

8.2.10 Delete RAID Group

This command displays a dialog box to let user choose RAID groups to delete.

40

Copyright © 2004 Silicon Image Inc. SATARAID5 User’s Manual

8.2.11 RAID Group Summary

This command displays a dialog box to show all RAID groups’ group ID, configuration, and status.

The RAID Group Summary window has it’s own menu bar. All options available via the menu bar are shown below

File Options

Exit Sorting…

Fields…

Exit

This command closes the RAID Group Summary window.

SATARaid5 User’s Manual Copyright © 2004 Silicon Image Inc.

41

Sorting

This command displays a dialog box to let user choose up to 3 items to sort RAID group items in the RAID Group list.

Fields

This command displays a dialog box to let user choose which fields will be shown in the RAID Group Summary window.

42

Copyright © 2004 Silicon Image Inc. SATARAID5 User’s Manual

This command displays the Task Manager window. The Task Manager window lists all RAID and disk management tasks that have been started and/or done. This window provides user the ability to schedule any RAID and disk management operations including RAID group creation, rebuild, and test.

The Task Manager window has it’s own menu bar. All options available via the menu bar are shown below

Open… Sorting… Modify…

Save… Fields… Suspend…

Print… Resume…

Exit Cancel…

Delete…

Open

This option will be available in future revisions.

Save

This option will be available in future revisions.

Print

SATARaid5 User’s Manual Copyright © 2004 Silicon Image Inc.

43

This option will be available in future revisions.

Exit

This command closes the Task Summary window.

Sorting

This command displays a dialog box to let user choose up to 3 items to sort task items in the task list.

Fields

This command displays a dialog box to let user choose which fields will be shown in the task list.

Modify

Copyright © 2004 Silicon Image Inc.

44

SATARAID5 User’s Manual

This command allows user to modify parameters of the selected task items. The following is an example of changing rebuild priority for a rebuild task.

Suspend

This command allows user to suspend the selected task items.

Resume

This command allows user to resume the suspended task items.

SATARaid5 User’s Manual Copyright © 2004 Silicon Image Inc.

45

Cancel

This command allows user to cancel the selected task items.

Delete

This command displays a dialog box to let user delete the selected task items from the task list in Task Summary window. The following dialog box will pop up to get confirmation from the user.

46

Copyright © 2004 Silicon Image Inc. SATARAID5 User’s Manual

This command displays the Event Log window. The Event Log window displays SATA device-related events that occur while

SATARAID5 is running.

The Event Log window has it’s own menu bar. All options available via the menu bar are shown below

File Options

Exit Sorting…

Fields…

Exit

This command closes the Event Log window.

SATARaid5 User’s Manual Copyright © 2004 Silicon Image Inc.

47

Sorting

This command displays a dialog box to let user choose up to 3 items to sort event items in the event log.

Fields

This command displays a dialog box to let user choose which fields will be shown in the event log.

48

Copyright © 2004 Silicon Image Inc. SATARAID5 User’s Manual

8.2.14 Resources

This command displays the Resource Information window. This feature is for debugging purpose only.

8.2.15 Create Legacy RAID Group

This command displays a dialog box to let user create legacy RAID group. This item is disabled if new RAID groups exist.

User needs to select the following parameters:

RAID Group: Select a group ID from the available ID list

Configuration: Striped (for RAID 0)

Capacity: Select from a list of RAID group size, current options are from 256 MB to 100 GB, and MAX.

Chunk Size: Select one from the available list: 8, 16, 32, 64, 128 (KB). RAID 1 set does not require this.

Devices: Select RAID member devices from the available device segment list

SATARaid5 User’s Manual Copyright © 2004 Silicon Image Inc.

49

8.2.16 Rebuild Legacy RAID Group

This command displays a dialog box to let user choose a replacement segment to rebuild a non-fault tolerant legacy RAID group.

8.2.17 Delete Legacy RAID Group

This command displays a dialog box to let user choose legacy RAID groups to delete. This item is disabled if no legacy RAID groups exist.

50

Copyright © 2004 Silicon Image Inc. SATARAID5 User’s Manual

8.2.18 Convert Legacy RAID Group

This command displays a dialog box to let user choose legacy RAID groups to convert to new RAID groups of the same RAID type (configuration). This item is disabled if no legacy RAID groups exist.

8.2.19 Create Legacy Spare

This command displays a dialog box to let user create legacy spare drive. This item is disabled if new RAID groups exist.

SATARaid5 User’s Manual Copyright © 2004 Silicon Image Inc.

51

8.2.20 Delete Legacy Spare

This command displays a dialog box to let user delete legacy spare drive. This item is disabled if no legacy spare drive exists.

8.2.21 Convert Legacy Spare

This command displays a dialog box to let user choose legacy spare drives to convert to new spare drives. This item is disabled if no legacy spare drives exist.

52

Copyright © 2004 Silicon Image Inc. SATARAID5 User’s Manual

This command opens an interactive help dialog using the standard Windows help interface.

This option will be available in future revisions.

8.2.23 About

This command displays a dialog box with more information about the SATARAID5 program, including the revision level.

SATARaid5 User’s Manual Copyright © 2004 Silicon Image Inc.

53

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement