Data sheet Power Supply CP-ASI/2.8 Primary switch mode power supply for AS-interface The CP-ASI power supply range is specifically designed with integrated data decoupling for the supply of AS-Interface systems. Up to 62 slaves (binary I/O devices) can be supplied with a single two-conductor cable. Characteristics –– Rated output voltage 30.5 V DC –– Rated output current 2.8 A –– Rated output power 85 W –– Rated input voltage 115 or 230 V AC, configurable –– Infrared addressing mode –– High efficiency of up to 90.5 % –– Low power dissipation and low heating –– Free convection cooling (no forced cooling with ventilators) –– Ambient temperature range during operation -10…70 °C –– Open-circuit, overload and short-circuit stable –– Integrated input fuse –– Tool-free mounting on DIN rail as well as demounting –– LEDs for the indication of operational states 2CDC271002S0012 The configurable IR addressing mode allows the easy assign of new ID addresses by means of an external infrared programming unit. Approvals A UL 508, CAN/CSA C22.2 No.107.11) H 1) UL 60950-1, CAN/CSA C22.2 No. 60950-11) Approvals refer to rated input voltage Uin Marks a CE Order data Type Input voltage range Rated output voltage Rated output current Order code CP-ASI/2.8 85-132 V AC 30.5 V DC 2.8 A 1SVR427090R0280 184-264 V AC Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected] Functions 1 Output +, -, +, -, SHIELD: output terminals 1 2 3 4 2 Indication of operational states AS-I OK: green LED – output voltage OK 3 Configuration of operation mode Jumper 4 Indication of operational states IR ADDRESSING ON: red LED – infrared addressing mode active 2CDC271002S0012 5 5 Circuit diagram 6 6 Input voltage selector Adjustment of input voltage 7 7 Input L, N, PE: input terminals Application The primary switch mode power supply is specifically designed with integrated data decoupling for the supply of ASinterface systems. It operates at two selectable input voltage ranges and can be used worldwide, within compact dimensions. The easy-to-set front-face jumper allows the assignment of new ID addresses to slaves by means of an external infrared programming unit without disconnecting them from the AS-Interface cable. Up to 62 binary I/O devices can be connected and supplied according to the AS-interface bus technology with a single two-conductor cable. The communication signals are modulated onto the slaves’ DC supply voltage of the AS-interface system, which therefore requires a specific power supply with integrated data decoupling. Operating mode By means of the input voltage selector the input voltage can either be set to 115 V AC or 230 V AC. The front-face jumper allows the configuration of the operation mode of the power supply, i.e. “1-2 COMMUNICATION MODE” or “2-3 IR ADDRESSING MODE” to enable communication control and supply of AS-interface slaves or to interrupt the data communication for the assignment of new ID addresses to participants by means of an external infrared programming unit. The green LED “AS-I OK” is on during normal operation, i.e. when the output voltage exceeds 30 V DC, and is off at overload. The red LED “IR ADDRESSING ON” is on when data communication has been interrupted by means of the jumper. Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected] Installation The device must be installed by qualified persons only and in accordance with the specific national regulations (e.g. VDE, etc.). The devices are maintenance-free chassis-mounted units. Before installation DANGER! Components with high stored energy and circuits with high voltage Danger to be electrocuted! Disconnect the system from the supply network and protect against switching on before any installation, maintenance or modification work. Do not introduce any objects into the unit and do not open the unit. Ensure that the service personnel is protected against inadvertent contact with parts carrying energy. Mounting 2CDC273001F0012 The switch mode power supply can be snapped on a DIN rail (TH 35-15 or TH 35-7.5 according to IEC/EN 60715) as shown in the accompanying picture. For that the device is set with its mounting rail slide on the upper edge of the mounting rail and locked by lifting it downwards. click Demounting 2CDC273002F0012 Remove the switch mode power supply as shown in the accompanying picture. For that the latching lever is pulled downwards by means of the screwdriver. Alternatively the upperside of the latching lever can be pressed to release the device. Then in both cases the device can be unhinged from the mounting rail edge and removed. Alternative: Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected] Mounting position The devices have to be mounted horizontally with the input terminals on the bottom. In order to ensure a sufficient convection, the minimum distance to other modules should not be less than 15 mm (0.59 in) in vertical and 25 mm (0.98 in) horizontal direction. 2CDC 272 001 F0012 O UT IN Electrical connection _ + + _ SH SH PWM N o L N 2CDC272003F0012 + L +, - Output voltage SH Shield L, N Input voltage o Protective earth o Preparations: – Connect to mains according to the specific national regulations. – Power supply cables and unit must be sufficiently fused. A disconnecting device has to be provided for the power supply to disengage unit and supply cables from supply mains if required. – We recommend to choose the cable section as large as possible in order to minimize voltage drops. – In order to ensure sufficient air-cooling the distance to other devices has to be considered. Instructions: 1. Connect the input terminals L and N. 2. Connect the protective earth conductor to terminal o (protection class I). 3. Provide a suitable disconnecting device (e.g. line protection switch) in the supply line acc. to IEC/EN 60950-1. 4. Rate the lines for the maximum output current (considering the short-circuit current) or provide a separate fuse protection. The input side is protected by an internal input fuse. 5. Observe the polarity. Connect the ‘shield’ terminal on the AS-i power supply to the machine ground so that the AS-i system is symmetrically operated against this machine ground. This improves noise sensitivity in case of symmetrical interference on the AS-i cable. The device is overload, short-circuit and open-circuit proof. The secondary side of the power supply unit is electrically isolated from the input. Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected] Operation DANGER! High current Risk of electric arcs and electric shocks! Do not modify the installation (primary and secondary side). Intended use. CAUTION! Depending on the operation conditions the enclosure can become very hot Risk of burns! In order to ensure sufficient air-cooling the distance to other devices has to be considered. The device is intended for use as a primary switch mode power supply for AS-interface systems. Any other usage is not supported by the manufacturer. Other usage may impair safety and cause operational difficulties or destruction of the unit. Service The internal fuse is not user-replaceable. If the internal fuse blows, most probably the device is defective. In this case, an examination of the switch mode power supply by the manufacturer is necessary. Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected] Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated L, N Input circuit – Supply circuit Rated input voltage Uin Input voltage range switch position 115 V 100-120 V AC switch position 230 V 220-240 V AC switch position 115 V 85-132 V AC switch position 230 V 184-264 V AC Frequency range AC Typical input current 47-63 Hz switch position 115 V 2.0 A switch position 230 V 0.9 A Typical power consumption 94 W Inrush current limiting / I²t (cold start) < 20 A (132 V AC) / approx. 1.5 A²/s < 38 A (264 V AC) / approx. 1.8 A²/s Discharge current towards PE Power failure buffering time < 3.5 mA at 115 V AC min. 35 ms at 230 V AC min. 40 ms Transient overvoltage protection varistor Internal input fuse 2.5 A slow acting / 250 V AC External fusing (not necessary, but recommended) circuit breaker with C characteristic min. 6 A, or alternatively 10 A with B characteristic Power Factor Correction (PFC) at 115 V AC 0.58 at 230 V AC 0.53 Indication of operational states Output voltage IR addressing mode AS-I OK IR ADDRESSING ON LED green LED red Output circuit +, - Rated output power 85 W Rated output voltage 30.5 V DC Tolerance of the output voltage ±3% T a ≤ 60 °C Rated output current Ir Derating of the output current 60 °C < Ta ≤ 70 °C 2.8 A 2.5 % / °C Control time < 2 ms Starting time after applying the supply voltage max. 400 ms Rise time max. 100 ms Residual ripple BW = 500 kHz typ. < 50 mVpp Switching peaks BW = 20 MHz typ. < 100 mVpp Output circuit – No-load, overload and short-circuit behaviour Characteristic curve of output U/I characteristic curve Short-circuit protection continuous short-circuit stability Short-circuit behavior continuation with output power limiting Current limiting at short circuit min / max 3.2 A / 4.6 A Overload protection output power limiting No-load protection continuous no-load stability Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected] General data MTBF on request Power dissipation typ. < 9.1 W (230 V AC, 2.8 A) Efficiency typ. 90.5 % Duty time 100 % Dimensions (W x H x D) Weight product dimensions 49 x 131 x 107 mm (1.93 x 5.16 x 4.21 in) packaging dimensions 151 x 65 x 140 mm (5.94 x 2.56 x 5.51 in) net weight 0.495 kg (1.019 lb) gross weight 0.568 kg (1.252 lb) Material of housing metal Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position horizontal Minimum distance to other units horizontal / vertical 15 mm / 25 mm (0.59 / 0.99 in) Degree of protection housing / terminals IP 20 Protection class I Electrical connection Wire size fine-strand with wire end ferrule 0.5-4 mm² (20-12 AWG) fine-strand without wire end ferrule 0.5-4 mm² (20-12 AWG) rigid 0.5-6 mm² (20-10 AWG) Stripping length 7 mm (0.28 in) Tightening torque 0.8 Nm (7.08 lb.in) Environmental data Ambient temperature ranges operation -10...+70 °C rated load -10...+60 °C storage -25...+85 °C Vibration 2-17.8 Hz, amplitude ± 1.6 mm sinusoidal (IEC/EN 60068-2-6) random (IEC 60068-2-64) Shock, half-sine (IEC/EN 60068-2-27) 17.8 Hz - 500 Hz, 2 g 2-800 Hz 0.5 s² (s³) 15 g (6 ms), 10 g (11 ms) Isolation data Rated insulation voltage Ui (IEC/EN 60950-1, EN 50178) Rated impulse withstand voltage Uimp (EN 50178) input / output 300 V input / PE 300 V output / PE 50 V shield / output 50 V shield / PE 50 V input / output 6 kV 1.2/50 µs input / PE 4 kV 1.2/50 µs output / PE Power-frequency withstand voltage test (test voltage) (routine test / type test) input / output 2.5 kV AC / 3.0 kV AC input / PE 2.5 kV AC / 2.5 kV AC output / PE Pollution degree (IEC/EN 60950-1) Overvoltage category (IEC/EN 60950-1, EN 50178) 500 V 1.2/50 µs 500 V AC / 500 V AC 2 input II (IEC/EN 60950-1), III (EN 50178) output II (IEC/EN 60950-1), II (EN 50178) Standards Low Voltage Directive 2006/95/EC EMC Directive 2004/108/EC RoHS Directive 2011/65/EC Electrical safety IEC/EN 60950-1 Protective low voltage SELV (IEC/EN 60950-1), PELV Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected] Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2 Level 4 (8 kV / 15 kV) radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3 (10 V/m) electrical fast transient/burst IEC/EN 61000-4-4 input circuit: Level 4 (4 kV) output circuit: Level 3 (2 kV) surge IEC/EN 61000-4-5 conducted disturbances, induced by radio- IEC/EN 61000-4-6 input circuit: L-L Level 3 (2 kV) / L-PE Level 4 (4 kV) output circuit: Level 1 (0.5 kV) Level 3 (10 V, 150 kHz - 80 MHz) frequency fields voltage dips, short interruptions and voltage IEC/EN 61000-4-11 Class 3 variations Interference emission IEC/EN 61000-6-3 high-frequency radiated IEC/CISPR 22, EN 55022 Class B high-frequency conducted IEC/CISPR 22, EN 55022 Class B IEC/EN 61000-3-2 Class A limits for harmonic current emissions Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected] Technical diagrams Output behaviour Uout [V] 2CDC272007F0012 32 28 24 20 16 12 8 4 0 0 1 2 3 Iout [A] 4 Characteristic curve of output at Ta = 25 °C Temperature behaviour 2CDC272006F0212 Iout [A] 2.8 2.1 -10 60 70 Ta [°C] Characteristic curve of temperature at rated load Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected] Dimensions in mm and inches 102 4.02” 49 1.93” 62 2.44” 2CDC272014F0012 131 5.16” 62 2.44” 94 3.78” 5 0.20” Further documentation Document title Document type Document number Electronic products and relays Technical catalogue 2CDC 110 004 C02xx Power supply units Application manual 2CDC 114 048 M020x CP-ASI/2.8, CP-ASI/4.0, CP-ASI/8.0 Instruction manual 1SVC 427 090 M0000 You can find the documentation on the internet at ABB Website -> Control Products -> Power Supplies. CAD system files You can find the CAD files for CAD systems at ABB Website -> Low Voltage Products & Systems -> Control Products -> Power Supplies. Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]
advertisement