WaterWorks GUDV3T is a three-way diverter valve for thermostatic shower systems that allows you to control the flow of water between a maximum of three devices, such as a shower head, handshower, and body jets, without the water flowing simultaneously from multiple devices. It features tactile feedback at each position, making it easy to switch between devices even with your eyes closed. The valve has a rough-in depth that varies depending on the trim used and requires a minimum water pressure of 20 psi and a maximum pressure of 85 psi.

advertisement

Waterworks GUDV3T ViaWorks Three Way Diverter Valve for Thermostatic Shower Systems Installation Guide | Manualzz

STYLE No. GUDV3T, GU3TDV

ViaWorks Three Way Diverter Valve for

Thermostatic Shower Systems

INSTALLATION GUIDELINES

STYLE NO. GUDV3T, GU3TDV†

IMPORTANT:

¾ ALL VALVES AND TRIMS SOLD SEPARATELY.

¾ To ensure this DIVERTER VALVE is installed properly, you must read and follow these guidelines.

¾ The owner/user of this DIVERTER VALVE must keep this information for future reference.

¾ This DIVERTER VALVE must be paired with a THERMOSTATIC

VALVE (sold separately).

¾ This VALVE CANNOT be used with a DIVERTING TUB SPOUT.

¾ CAUTION: The VALVE rough-in depth is measured from the center of the inlets to the surface of the finished wall and VARIES depending on the TRIM used.

¾ This DIVERETER VALVE and associated TRIM (SOLD SEPARATELY) must be installed by a professional licensed contractor and must be onsite prior to rough-in. This allows the installer to visualize the installation.

¾ This DIVERTER VALVE is sold partially assembled but shown fully disassembled for illustrative and service purposes only. Inspect the VALVE to ensure you have all the parts required for proper installation.

¾ Be sure your installation conforms to all federal, state, and local codes. In the State of Massachusetts, all installations must comply with the rules and regulations set forth within 248 CMR.

PRODUCT SUPPORT | 800.927.2120 | WATERWORKS.COM

¾ If further assistance is required, please contact Product Support at 1-800-927-2120 Monday through Friday, 8am – 6pm EST.

¾ Refer to the separate Service Parts Documents for available replacement parts.

TECHNICAL DETAILS:

DETAIL SPECIFICATION

INLET/OUTLET CONNECTIONS

FITTINGS HOLE DIAMETER

ROUGH-IN DEPTH

UNRESTRICTED MAX FLOW RATE @ 45 PSI [3 bar]

1/2” MALE NPT †

Ø2” [51mm]

VARIES ‡

10gpm [38L/min]

WATER PRESSURE MAXIMUM

WATER PRESSURE MINIMUM

85psi [6.0 bar]

20psi [1.5 bar]

WATER PRESSURE RECOMMENDED 45psi [3.0 bar]

† Style No. GU3TDV is provided with 4 BSPP ADAPTERS. ADAPTERS are packaged separately and assembly is required. Replacement ADAPTERS can be ordered separately:

● Universal 1/2” NPT Female x 1/2” Male BSPP Adapter

Style No. UNUK03

‡ Refer to the Installation Guidelines of the specific DIVERTER VALVE TRIM being used for the

MAXIMUM and MINIMUM rough-in depth dimensions.

PAGE 1 OF 3 | UPDATED ON 5.19.2022

INSTALLATION GUIDELINES

VALVE FUNCTION AND HANDLE OPERATION:

¾ CAUTION: When this DIVERTER VALVE is paired with a DIVERTER VALVE TRIM that has specific device MARKINGS, it is crucial that the outlet ports are correctly plumbed to those specific devices (i.e. handshower and shower head)

¾ The required THERMOSTATIC VALVE (sold separately) only mixes hot and cold water, it does not have an on/ off/ or volume control function. Mixed water flows out at a fixed volume to the DIVERTER VALVE which has

3 positions, each 60° apart.

● 3 ON positions that can direct water flow to a

MAXIMUM of 3 devices. Water CANNOT flow out of the devices simultaneously (i.e. out of the shower head AND handshower together).

● 3 OFF positions. 1 in between each ON position.

● The DIVERTER VALVE incorporates tactile feedback at each position.

56G:46

@F T =6E

4

DEVICE

OUTLET

"A"

56G:46

@F T =6E

3

>:I65

H2E6C

:?=6E

[GUDV3T SHOWN]

ROUGH-IN AND VALVE PREPARATION:

¾ Check incoming water pressure.

¾ IMPORTANT:

● The VALVE rough-in depth is measured from the center of the inlets to the surface of the finished wall and varies depending on the TRIM used.

● Refer to the Installation Guidelines of the specific DIVERTER VALVE TRIM being used for the MAXIMUM and MINIMUM rough-in depth dimensions.

¾ CAUTION:

● DO NOT APPLY DIRECT HEAT TO THE VALVE.

Pre-solder any connections to prevent damage to the CARTRIDGE and other internal components.

● The DIVERTER VALVE TRIM components (i.e.

HANDLE and TRIM PLATE) may be packaged separately from each other.

[IN/OUT

MARKINGS]

DIVERTER

VALVE

CENTER

OF

INLET

‡ Refer to the Installation Guidelines of the specific DIVERTER VALVE TRIM being used for the MAXIMUM and MINIMUM rough-in depth dimensions.

THREADED

TUBE

"A"

ROUGH-IN

DEPTH

"B"

FITTINGS

HOLE

PRODUCT SUPPORT | 800.927.2120 | WATERWORKS.COM

STYLE No. GUDV3T, GU3TDV

ViaWorks Three Way Diverter Valve for

Thermostatic Shower Systems

[HANDLE OPERATION]

DIM

A

B

VALUE

VARIES ‡

Ø2” [51mm]

FINISHED

WALL

TILE GUARD

PAGE 2 OF 3 | UPDATED ON 5.19.2022

INSTALLATION GUIDELINES

* Style No. GU3TDV is provided with 4 BSPP ADAPTERS.

DIVERTER

VALVE FINISHED

WALL

MOUNTING

TABS

[BLOCKING

RECOMMENDED]

CENTER

OF INLET

ROUGH-IN

DEPTH

1. The DIVERTER VALVE rough-in depth is measured from the center of the inlet to the surface of the finished wall and varies depending on the TRIM being used.

* TURN ON WATER AND CHECK FOR LEAKS!

CARTRIDGE

STEM

"OFF"

"A"

"OFF"

"B"

"OFF"

[360°]

"C"

4. Turn on the water supply and operate the

CARTRIDGE STEM to flush out the supply lines, verify all VALVE positions are functioning properly, and check for leaks. Ensure the supply lines have been fully flushed then turn off the water.

PRODUCT SUPPORT | 800.927.2120 | WATERWORKS.COM

[1/2"

MALE NPT

THREADS] *

DIVERTER

VALVE

1/2"

COPPER

SUPPLY

[IN/OUT

MARKINGS]

2. From the THERMOSTATIC VALVE (sold separately) being used, run a copper supply line to the proper height of the DIVERTER VALVE making sure it’s positioned according to the IN/OUT MARKINGS so that mixed water flows into the inlet and all piping and fittings are secured.

FINISHED

WALL

TILE GUARD

5. Install the TILE GUARD to protect the DIVERTER

VALVE during the completion of the finished wall and to create the exact opening required to ensure access to the CARTRIDGE for future servicing.

STYLE No. GUDV3T, GU3TDV

ViaWorks Three Way Diverter Valve for

Thermostatic Shower Systems

* Style No. GU3TDV is provided with 4 BSPP ADAPTERS.

1/2"

COPPER

PIPE

1/2"

COPPER

SUPPLY

1/2"

COPPER

PIPE

3. Run 1/2” copper supply lines from the outlet ports to the 3 desired devices making sure all piping and fittings are secured.