Timberk TIM S8 07H, 09H, 12H, 18H, 24H split-system air conditioner User manual
Below you will find brief product information for split-system air conditioner TIM S8 07H, split-system air conditioner TIM S8 09H, split-system air conditioner TIM S8 12H, split-system air conditioner TIM S8 18H, split-system air conditioner TIM S8 24H. These split-system air conditioners are for cooling your home, and they come with both indoor and outdoor units. They also feature a variety of settings, including cooling, heating, dry, and fan, that you can adjust to match your needs. The air conditioners come with a remote control that you can use to set the temperature, adjust the airflow direction, and turn the device on and off.
Advertisement
Advertisement
17 18
User manual
( ,
)
Electric air conditioner
(split system , in set of two units)
/
Models
-
Air conditioner units for indoor installation
AC TIM 07H S8
AC TIM 09H S8
AC TIM 12H S8
AC TIM 18H S8
AC TIM 24H S8
-
Air conditioner units for outdoor installation
AC TIM 07H S8-01
AC TIM 09H S8-01
AC TIM 12H S8-01
A
C TIM 18H S8-01
AC TIM 24H S8-01
Outlook of devices, and also colour scores can be revised without any special advance notices.
CONTENTS
1.Important information
2.Safeguards
3.Specifications
4.Appliance description
5.Delivery set
6.Appliance control
Control panel for indoor unit
Remote control board
7.Operating modes
8.Maintenance
9.Troubleshooting
10.Service life
11.Utilization rules
Dear customer!
We thank you for your happy choice and buying of a domestic air conditioner Timberk. It will serve you for a long time.
1. IMPORTANT INFORMATION
The appliance is designed for air cooling in domestic premises. The manufacturer reserves the right to introduce changes in design, configuration and processing of the article with a view to improve its properties without any prior notification of customers. There may be some misprints in text and digital notations of the present manual.
If after reading of this manual you have any questions concerning work and operation of the appliance, please, refer to a shop assistant or to a specialized service center for further explanations.
The article has a label with all the needed technical data and other useful information about the appliance. Use the appliance only for its intended purpose indicated in this manual.
4
5
4
4
2
2
3
6
7
7
7
5
6
2. SAFEGUARDS
1.Don't try to install the conditioner by yourself. Call for a qualified installation specialist.
2.While using the air conditioner, it is necessary to observe several precautions. Incorrect operation due to ignoring of precautions may result in personal injury of a user and other people, as well as in damaging of their property.
3.The electric appliance should be under observation while operated, especially if there are any children near it.
4.Don't pass your fingers or foreign objects through an air outlet grille of indoor and outdoor units, since it may result in a trauma caused by a revolving fan.
5.Don't let children turn the conditioner on by themselves. Children may turn the conditioner on only under the care of adults.
6.Don't try to repair the conditioner by yourself. Internal units of the conditioner carry a voltage and it is life-threatening! For repair of the appliance refer to an authorized service center.
7.Don't use the appliance if it is faulty, or if it was dropped or damaged.
8.Don't open a front panel of the appliance during its work.
9.Don't dismantle and modify the appliance.
10.Unplug the conditioner immediately, if it emits strange odours or smoke.
11.Don't splash and pour water and other liquids on the conditioner.
12.Always unplug the conditioner during a lighting storm.
13.Always unplug the conditioner, when it is not used.
14.Before cleaning and maintenance of the conditioner unplug it. Cleaning and maintenance should be performed in accordance with instructions of this manual.
15.To ensure the effective work of the conditioner, operate it in environment described in the present manual.
16. Don't use dangerous chemicals for cleaning of the appliance and don't let them on the appliance.
17.When removing an air filter, don't touch metal parts of the appliance.
18.To avoid overheating and risk of flash fire, as well as damage of internal electric network, don't change the length of a power cord and don't connect the appliance via extension cords.
19. To avoid electrical hazards, damaged power cord must be changed only at authorized service centers qualified professionals.
20. To avoid risk of electric shock, do not place the power cord near a heater and flammable or combustible substances.
21. Do not start or stop the unit by connecting or disconnecting electrical power.
19.To avoid electric shock, a damaged power cord should be replaced only in authorized service centers by qualified specialists.
2 w ww.timberk.com
Electric air conditioner (split system, in set of two units)
ENGLISH
20.To avoid electric shock, don't place the power cord near heating appliances and flammable or combustible substances.
21.Don't start and stop the appliance by power-up and down.
22 .Don't press the buttons of the remote control board by anything but your fingers.
2 3 .Don't use the appliance for purposes not intended by this user manual.
3.
SPECIFICATIONS
Model
Indoor unit
Outdoor unit
Capacity (cooling) BTU (kW)
Capacity (heating) BTU (kW)
Rated input (cooling) W
Rated input (heating) W
Voltage V/Hz
Rated current (cooling/heating) A
Air circulation (indoor unit) m3/h
Air circulation (outdoor unit) m3/h
Noise level (indoor unit) dB(A)
Noise level (outdoor unit) dB(A)
Refrigerant
Energy class (cooling/heating)
Electrical protection class
Degree of protection against moisture (indoor unit)
Degree of protection against moisture (outdoor unit)
Net weight, indoor unit (kg)
Net weight, outdoor unit (kg)
Gross weight, indoor unit (kg)
Gross weight, outdoor unit (kg)
Net dimensions, indoor unit (mm)
Net dimensions, outdoor unit (mm)
Packing dimensions, indoor unit (mm)
Packing dimensions, outdoor unit (mm)
AC TIM 07H S8
AC TIM 07H S8
AC TIM 07H S8-01
7000 (2,05)
7500 (2,2)
800
770
220/50
3,6/3,5
430
1415
32-36
50
R410A
E/D
I class
IPX0
IPX4
6,2
23,3
7,8
25,3
718x240x180
600x500x232
805×305×255
745x550x353
AC TIM 09H S8
AC TIM 09H S8
AC TIM 09H S8-01
9000(2,64)
9500 (2,78)
970
950
220/50
4,4/4,3
430
1415
32-36
52
R410A
D/D
I class
IPX0
IPX4
6,2
23,4
7,8
25,5
718x240x180
600x500x232
805×305×255
745x550x353
AC TIM 12H S8
AC TIM 12H S8
AC TIM 12H S8-01
12000 (3,52)
12500 (3,66)
1280
1270
220/50
5,8/5,8
530
2040
34-39
55
R410A
D/D
I class
IPX0
IPX4
7,0
29,7
8,7
32,8
770x240x180
700x552x256
855×305×255
803x598x380
AC TIM 18H S8
AC TIM 18H S8
AC TIM 18H S8-01
18000 (5,28)
18500 (5,42)
2150
1900
220/50
9,8/8,6
780
2340
44-48
58
R410A
E/D
I class
IPX0
IPX4
9,3
36,7
11,8
39,6
898x280x202
760x552x256
995x365x298
863x598x376
AC TIM 24H S8
AC TIM 24H S8
AC TIM 24H S8-01
24000 (7,03)
24500 (7,18)
2900
2700
220/50
13,2/12,3
780
3350
44-48
60
R410A
E/E
I class
IPX0
IPX4
9,3
50,2
12,2
54,2
898x280x202
902x650x307
995x365x298
1037x705x433 w ww.timberk.com
Electric air conditioner (split system, in set of two units)
3
ENGLISH
4. APPLIANCE DESCRIPTION
1
The conditioner consists of indoor and outdoor units connected by pipelines. The conditioner may be controlled from a remote control board or from an indoor unit control panel.
1 1
10
2
3
7
8
4
9
6
5
Fig . 1
1. Conditioner unit for indoor installation.
2. Front panel.
3. Air-intake grille of the indoor unit.
4. Control panel (start/stop button, mode selection button) if there is no remote control board.
5. Blinds (deflectors) for distribution of treated air.
6. Air outlet of the indoor unit.
7. Copper tube for gas (freon), connection line*.
8. Tube for condensate removal*.
9. Air-outlet grille of the outdoor unit.
10. Conditioner unit for outdoor installation.
11. Air-intake grilles of the outdoor unit.
5. DELIVERY SET
Complete set of air conditioner (split system) includes:
Conditioner unit for indoor installation -1 piece
Conditioner unit for outdoor installation -1 piece
Remote control board -1 piece
Batteries for remote control board - 2 pcs.
User manual -1 piece
Guarantee slip -1 piece
Packing of indoor-installation unit -1 piece
Packing of outdoor-installation unit -1 piece
4
* not supplied w ww.timberk.com
Electric air conditioner (split system, in set of two units)
6. APPLIANCE CONTROL
The conditioner may be controlled from a remote control board or from an indoor unit control panel.
Figure 2. Description of indoor unit control panel
1 . If you press the button once, the conditioner will start working in cooling mode. In 30 minutes the conditioner will switch to automatic mode.
2 . If you press the button twice, the conditioner will start working in heating mode. In 30 minutes the conditioner will switch to automatic mode.
3 . The air conditioner will be switched off next time you press the button.
4. «Auto-restart» function: switching off and switching on. With the use of this function the conditioner may keep the specified settings after shutdown or voltage drop. To cancel the function, hold the «on/off» button on the conditioner for 10 seconds until you hear an audio signal. If you hold the «on/off» button on the conditioner repeatedly for 10 seconds until you hear an audio signal, the «Auto-restart» function will be activated * .
The front panel of air conditioner there is a display that shows the current temperature and defined, and indicators * display modes and settings: power, night mode, temperature, timer, compressor operation (see Figure below**).
The front panel of the conditioner comprises a display showing specified and current temperature, as well as indicators* reflecting modes and parameters of work: power supply, sleep mode, temperature, timer, compressor operation (see the figure below**).
* Presence of this function depends on the delivery lot.
Figure 3. Description of remote control board
13
14
17
15
) Power supple indicator b) Sleep mode indicator c) Temperature indicator d) Timer indicator e) Operation indicator
* use of particular indicators depends on model and series.
** design of indicator symbols may differ depending on model and series.
SLEEP SUPER ECO
FEEL
COOL
DRY
FAN
HEAT
TIMER ON TIMER OFF
AUTO
HIGH
MID
LOW
SWING
MODE
TIMER
F AN
SUPER
SWING SLEEP
ECO
12
20
16
19
18
12.Button «ON/OFF» (Power). Using this button, you may turn the conditioner on or off.
13.Buttons «TEMP» (increase/decrease). Using this button, you may set needed air temperature indoors.
14.Button «FAN». Using this button, you may select rotation speed of the indoor unit fan: «Auto», «High», «Middle», «Low».
In Auto mode the fan speed will change automatically. In dry mode the fan speed will remain unchanged Low .
ENGLISH
15.Button «SWING». Using this button, you may regulate position of airoutlet blinds and forward treated air up and down.
16.Button «TIMER». Pressing this button, you may set the time for turning the conditioner on and off (set the time by pressing TEMP" buttons up and down). If the conditioner is off, you may set the time for automatic turning on in a set time interval. And vice versa, if the conditioner is on, you may set the time for automatic turning off. Before activation of the Timer function you may specify the needed settings.
17.Button «SUPPER». Using this button, you may turn the turbo mode on and off. In this mode the conditioner shows the maximum cooling (in cool mode) or heating (in heat mode) capacity.
18.Button «ECO» (Economic). Using this button, you may turn the economic mode on and off. In this mode temperature will increase (in cool mode) or decrease (in heat mode) slightly by 2° from the specified one.
19.Button «SLEEP» (Night Care). Using this button, you may turn the sleep mode on and off. In this mode, if working for cooling, the conditioner will increase temperature by 1 ° from the specified one within two hours. If working for heating, the conditioner will decrease temperature by 1 ° from the specified one within two hours. After 10 hours of operation the conditioner will turn off automatically.
20.Button for selection of operating mode «MODE». Using this button, you may select a needed operating mode: AUTO, COOL, DRY, HEAT, FAN.
Indication of the control board display shall correspond to selected modes.
Work with remote control board
Mounting and replacement of batteries: mount two LR03 alkaline batteries, according to polarity indicated on the remote control board.
In order to avoid malfunction of the remote control board do not insert used batteries or batteries of various types.
If the conditioner is not used for a long time, remove batteries from the board or else electrolyte may leak and damage the board.
In normal operation of the conditioner average service life of batteries will be about a half-year.
Replace batteries, if command receiving is not confirmed with an audio signal, or if the display does not show a sign of command transfer. When generating commands from the remote control board, point an IR-radiator at a remote-control signal receiver situated on the indoor unit. Hold the remote control board at the distance of no more than 8 m from the indoor unit. The remote control board will not work, if there are any curtains, doors or other things between it and the indoor unit. Protect the board from water and exposure to direct sunlight and heat sources. w ww.timberk.com
Electric air conditioner (split system, in set of two units)
5
ENGLISH
7. OPERATING MODES
AUTO mode (SMART)
The auto mode is turned on and off with the use of the button MODE on the remote control board.
1. While working in the AUTO mode, a microprocessor will automatically select COOL, FAN, HEAT or DRY modes based on the difference between actual and preset air temperature indoors.
2. If the AUTO mode does not provide comfort conditions, select the mode manually. In automatic mode, depending on air temperature in the room, the conditioner will select needed temperature parameters of its operation in the following order:
Temperature indoors Automatic mode sele ction
Automatically maintained tempe rature if <20° then HEAT mode shall be turned on 23 ° if 20° 26° if > 26° then DRY mode shall be turne d on then COOL mode shall be turned on
18°
23 °
COOL, HEAT and FAN
1. Turn the conditioner on pressing the "ON/OFF" button.
2. Pressing the "MODE" button, select COOL, HEAT or FAN mode manually.
3. Pressing the "TEMP" button (up-down), set the desired air temperature indoors (except for FAN mode).
4.Pressing the "FAN SPEED" button on the remote control board, select the fan rotation speed: AUTO, LOW, MIDDLE, HIGH, and the conditioner will start working in accordance with the selected setting.
5.To turn the conditioner off, press the "ON/OFF" button once again.
In the FAN mode air temperature indoors is not set.
DRY
Turn the conditioner on pressing the "ON/OFF" button. Pressing the "MODE" button, select the DRY mode. The conditioner will start working in the set mode. To turn the conditioner off, press the "ON/OFF" button once again.
NOTE
If there is a difference between set and actual air temperature in
DRY mode, the conditioner will automatically turn on in COOL or
FAN modes.
"SUPER" mode (TURBO)
When pressing the "TURBO" button on the remote control board, the conditioner will start working in turbo mode for maximum cooling (in cool mode) or for maximum heating (in heat mode).
6 w ww.timberk.com
Electric air conditioner (split system, in set of two units)
TIMER mode
Procedure of timing:
If the conditioner is off, then press the TIMER button to activate the automatic turning on. Pressing this button once again, set the time for turning the conditioner on in the set time interval. To cancel the timer mode, press the
TIMER button once again.
If the conditioner is working, then press the TIMER button to activate the automatic turning off. Pressing this button once again, set the time for turning the conditioner off in the set time interval. To cancel the timer mode, press the
TIMER button once again.
"SLEEP" mode
Button «SLEEP» (Night Care). Using this button, you may turn the sleep mode on and off. In this mode, if working for cooling, the conditioner will increase temperature by 1 ° from the specified one within two hours. If working for heating, the conditioner will decrease temperature by 1 ° from the specified one within two hours. After 10 hours of operation the conditioner will turn off automatically.
Regulation of treated air flow direction
Regulating the position of deflectors (blinds), set the direction of treated air flow ensuring uniform distribution of temperature and the most comfort conditions in the room. To change the position of deflectors, use the "SWING" button.
8. MAINTENANCE
Before cleaning unplug the conditioner.
Cleaning of the indoor unit and remote control board:
Indoor unit and remote control board should be cleaned with a dry soft cloth.
If the indoor unit is too unclean, moisten the cloth with cold water.
It is prohibited to clean the remote control board with moist cloth.
In order to avoid the damage of paint or details of the conditioner, do not clean it with brushes and do not leave them on the surface of indoor unit.
In order to avoid the damage of surface or deformation of the conditioner details, do not clean it with petrol, solvents, cleaning powders or other chemically active substances.
Before a sustained interruption in the conditioner work:
Turn the conditioner on for several hours in the FAN mode. It will allow you to dry its inner cavities
Unplug the conditioner. Remove the batteries from the remote control board.
Checks before starting:
Make sure that an air filter is installed.
Make sure that air inlet and outlet grilles of the outdoor unit are not blocked by foreign objects.
Cleaning of air filter
Air filter cleans the air entering the conditioner from dust and foreign particles. If the filter is contaminated, the conditioner capacity decreases sharply.
If the conditioner is operated permanently, the filter should be cleaned once per two weeks.
If the conditioner is installed in a room with dusty atmosphere, then the air filter should be cleaned more often.
To remove the filter, open the indoor unit panel.
Remove air filters. Clean the filter with a vacuum cleaner or rinse it in clean water. If the filter is contaminated heavily, clean it with a soft brush and wash in diluted washing solution, then dry it in a cool place.
While cleaning the filter with the vacuum cleaner, hold it with contaminated surface up. While washing the filter in water, hold it with contaminated surface down.
Do not dry the filter in the sun or near a fire.
Set the air filter to initial position and close the panel.
9. TROUBLESHOOTING
Failures and their possible reasons:
D_gjs pc
The conditioner does not work
Possible reason
Interruptions in power supply
Actions
Wait for restoration of power supply
Batteries in the remote control board are low Replace the batteries
Time of turning on is set by the timer
Wait till the conditioner turns on by the timer or cancel the timer setting
Insufficient cooling or heating capacity
The set air temperature is too high or too low Set the air temperature correctly
The air filter is clogged with dust Clean the air filter
Foreign objects block the air inlet and return air grillages of the outdoor unit
The conditioner works, but does not cool or heat the room
A three-minute delay of compressor turning on
The air temperature is set incorrectly
Remove foreign objects
Wait a little
Set the temperature correctly
ENGLISH
10.SERVICE LIFE
Service life of the appliance is 10 years provided that the respective installation and operation rules are observed.
Date of the conditioner manufacture is shown in a serial number of the device. For more details, please, ask a shop assistant.
11. UTILIZATION RULES
Upon expiration of the service life, the appliance should be utilized in accordance with norms, regulations and procedures effective in the place of utilization.
w ww.timberk.com
Electric air conditioner (split system, in set of two units)
7
7.
8.
9.
10.
11.
12.
1.
2.
3.
4.
5.
6.
...................................................................................................................
.........................................................................................................
................................................................................................
.......................................................................................................................
.......................................................................................................................
10
10
...............................................................................................................
...........................................................................
10
10
8
8
9
( ).......................................................................
.............................................................................................................................
..................................................................................................................
11
12
13
...................................................................................................
13
....................................................................................................................
.................................................................................................................
13
13
......................................................................................................
14
1.
!
Timberk.
.
.
,
.
8 w ww.timberk.
om
.
,
( -
.
,
, )
.
,
.
2.
1.
2.
.
3.
4.
,
5.
6.
7.
8.
9.
10.
,
11.
12.
.
13.
14.
.
.
.
.
!
,
15.
-
16.
17.
,
,
.
.
18.
.
.
.
,
,
.
.
,
,
.
.
.
.
.
,
.
.
.
,
,
.
,
.
19.
20.
21.
.
3.
(
(
) BTU ( )
) BTU ( )
(
) (
/
/ )
) 3/
) 3/
) ( )
) ( )
)
,
,
,
,
(
(
(
(
(
( /
,
,
,
,
(
(
( )
( )
( )
( )
)
( )
( )
( )
( )
)
)
AC TIM 07H S8
AC TIM 07H S8
AC TIM 07H S8-01
7000 (2,05)
7500 (2,2)
800
770
220/50
3,6/3,5
430
1415
32-36
50
R410A
E/D
I
IPX0
IPX4
6,2
23,3
7,8
25,3
718x240x180
600x500x232
805×305×255
745x550x353
.
.
,
22.
( ),
23.
,
.
,
.
,
AC TIM 09H S8
AC TIM 09H S8
AC TIM 09H S8-01
9000(2,64)
9500 (2,78)
970
950
220/50
4,4/4,3
430
1415
32-36
52
R410A
D/D
I
IPX0
IPX4
6,2
23,4
7,8
25,5
718x240x180
600x500x232
805×305×255
745x550x353
AC TIM 12H S8
AC TIM 12H S8
AC TIM 12H S8-01
12000 (3,52)
12500 (3,66)
1280
1270
220/50
5,8/5,8
530
2040
34-39
55
R410A
D/D
I
IPX0
IPX4
7,0
29,7
8,7
32,8
770x240x180
700x552x256
855×305×255
803x598x380
AC TIM 18H S8
AC TIM 18H S8
AC TIM 18H S8-01
18000 (5,28)
18500 (5,42)
2150
1900
220/50
9,8/8,6
780
2340
44-48
58
R410A
E/D
I
IPX0
IPX4
9,3
36,7
11,8
39,6
898x280x202
760x552x256
995x365x298
863x598x376
AC TIM 24H S8
AC TIM 24H S8
AC TIM 24H S8-01
24000 (7,03)
24500 (7,18)
2900
2700
220/50
13,2/12,3
780
3350
44-48
60
R410A
E/E
I
IPX0
IPX4
9,3
50,2
12,2
54,2
898x280x202
902x650x307
995x365x298
1037x705x433 w ww.timberk.
om
( , )
9
4.
2 3
.
.
1 1
10
7
8
1
4
9
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
1 1.
6 5
(
.
/
.
.
( ),
*.
)
,
.
.
.
5.
- 1 .
(
- 1 .
- 2 .
- 1 .
- 1
- 1 .
.
-
- 1 .
- 1 .
)
*.
.
.
:
. 1
.
,
10
* w ww.timberk.
om
.
( , )
6.
.
2.
,
.
.
.
,
« on / off »,
,
1.
2 .
30
30
3 .
4. «
.
.
.
.
»:
,
,
-
.
.
.
«
**).
»
«on/off»
.
10
* .
, , ,
) b ) c ) d ) e )
:
,
10
«on/off»
,
(
,
*,
*
**
.
.
,
3.
13
14
17
15
SLEEP SUPER ECO
FEEL
COOL
DRY
FAN
HEAT
TIMER ON TIMER OFF
AUTO
HIGH
MID
LOW
SWING
MODE
SUPER
TIMER
F AN SWING SLEEP
ECO
12
20
16
19
18
* .
1 2.
13.
14 .
15.
16.
17.
18.
19.
1°
20.
« ON / OFF » (Power) .
« TEMP » (
.
/
.
).
« FAN
« High »,
».
.
« SWING ».
.
« TIMER ».
(
,
.
« SUPER ».
)
« Middle »,
« Auto »
« Low ».
,
,
(
,
,
:
« Low ».
TEMP
.
).
« ECO » (Economic) .
.
- 2°
« SLEEP » (Night Care) .
. 10
.
.
, , ,
« MODE ».
.
,
.
1°
:
« Auto
-
»,
(
.
).
- 2°
.
, w ww.timberk.
om
( , )
11
7.
LR03,
.
.
,
,
,
,
.
.
.
,
1.
2.
,
,
«MODE»
,
( SMART)
.
.
:
8
,
,
.
,
:
.
.
.
,
-
.
. ị ֿ ג ו ֿ ז ֹ טי ז ֹ ּ ו הג ֿ ן ֿ דׂ ׂ если < 20°C если 20°C-26°C если >26°C
Автом атический выбор режим а то включается режим Обогрева то включается режим Осушения то включается режим Охлаждения
Автоматически поддерживаемая температура
23°C
18°C
23°C
1.
2.
3.
,
,
"MODE",
(HEAT)
"TEMP" (
(
(COOL, HEAT, FAN)
"ON/OFF".
-
(FAN)
),
.
).
(COOL),
12 w ww.timberk.
om
( , )
4.
:
"FAN"
5.
"MODE",
(DRY)
,
"ON/OFF".
.
,
,
"ON/OFF".
(DRY).
,
.
,
"ON/OFF".
.
,
.
.
,
"SUPER" ("TURBO")
)
"TURBO"
(
.
TIMER .
.
TIMER .
(TIMER)
:
,
,
"SLEEP
.
« SLEEP » (Night Care) .
10
.
.
.
1°
TIMER .
TIMER .
(
).
TEMP ,
TEMP ,
1°
.
"SWING".
,
8.
,
.
.
.
.
.
,
,
.
.
:
.
,
,
.
.
,
.
.
.
(
,
:
),
.
.
:
.
,
.
,
,
.
.
.
.
.
.
.
,
,
9.
:
Ệֿ ׂ חו ז ֹ ּ דהחטע Возможная причина Действия
Подождите, пока восстановится электропитание
Кондиционер не работает
Перебои в электропитании
Разрядились элементы питания пульта дистанционного управления
Задано время включения кондиционера по таймеру
Задана слишком высокая или слишком
Недостаточная холодо- низкая температура воздуха в помещении или
Воздушный фильтр забит пылью теплопроизводительность Посторонние предметы загораживают воздухозаборную или воздуховыпускную решетку наружного блока
Замените элементы питания
Подождите, пока кондиционер включится по таймеру, или отмените настройку таймера
Правильно задайте температуру воздуха
Очистите воздушный фильтр
Удалите посторонние предметы
Кондиционер работает, но не охлаждает и не обогревает помещение
Действует трехминутная задержка включения компрессора Немного подождите
Неправильно задана температура воздуха Правильно задайте температуру
10.
1 0
.
. .
11.
.
, , w ww.timberk.
om
( , )
13
12.
:
RU.0001.11
18. .
325;
28,
: 123308, .
: 115162, .
4, . +7 495 6044266,
+ 7 495 6044266.
, .
,
«
, .3,
».
.1, .
.
52161.2.40-2008,
51318.14.1-2006 .4,
51318.14.2-2006 .5,7,
51317.3.3-2008
51317.3.2-2006 .6,7
: RU C IL .
MP 18.
B .00006
: 26.01.2012 25.01.2015
* :
«
Timberk Home Heating Appliances company Ltd».
( ): Hamasger str. 10, Eilat, Israel,
«
: .
/
* :
»
, .
(499) 638-26-77
, 1, .1, 606
:
+ 7 (495) 6275285
.
:
*
.
\
,
\
,
,
.
,
14 w ww.timberk.
om
( , )
RU
BY
OS
TJ
1.
2.
3.
1.
2.
3
.
c
4.
.
,
:
10%,
.
Timberk
,
Timberk
:
(
,
)
.
( )
CIS
KG
KZ
UA
AK
www.timberk.com
Electric air conditioner (split system, in set of two units)
15
www.timberk.com
17 18

Download
Advertisement
Key features
- Cooling & heating
- Indoor & outdoor units
- Remote control
- Dry mode
- Fan mode
- Auto mode
- Turbo mode
- Economy mode
- Sleep mode
- Timer mode