Amprobe VPC-10 Voltage Continuity Tester Manual

Add to my manuals
2 Pages

advertisement

Amprobe VPC-10 Voltage Continuity Tester Manual | Manualzz

Instruction Manual m Safety Information

• Never use the tester if it or its test leads appear damaged

• Never apply more than 600V DC or 600V AC RMS between any terminal and earth ground.

( If the LED turns on it indicates the presence of voltage at the probe tip.

• When using the probes, do not touch the metal probe tips.

• Disconnect the live test lead before disconnecting the common test lead.

• Before each use, verify the tester’s operation by measuring a known voltage.

The tester automatically turns on when you place the probes across a complete circuit.

The tester selects continuity or dc or ac voltage mode based on the resistance or voltage between the probes. The tester automatically turns off when you remove the probes from the complete circuit.

Connect test leads across the source or load under measurement, the LEDs turn on at between 70% and 100% of their rated voltages.

600V DC maximum

600

600V RMS maximum

45Hz to 66Hz

Turn off circuit power before testing

Beeper indicates shorts lasting 1ms or longer

OPEN

Continuity

SHORT or 0-85 KΩ

220V AC

Continuity r Beeping

Specifications

Function

DC voltage(V)

Range

6,12,24,36,48,110,220

Continuity test: Audible threshold 0-85kΩ, Continuity beeper 2KHz

Maximum Voltage Between any Terminal and Earth Ground:

600 V Overvoltage Category III

Input Impedance: 1MΩ

Temperature: Operating: 5˚C (41˚F) to 40˚C (104˚F)

Storage : -30°C to +60°C

Altitude: Operating: 2000m; Storage:10,000m

Accuracy

-30% to 0% of reading

80% for Temp up to 31˚C decreasing linearly to 50% RH at 40˚C

Battery Type and Life: AA(2); 350 hours with NEDA 15˚F or IEC R6

Safety: Complies with EN61010-1:1993 for use in overvoltage CAT III environments

Pollution Degree: 2

For indoor use only

EMC Regulations: EN50081-1, EN50082-1

Replace the batteries when touching the leads together no longer turns on the continuity LED.

Disconnect probes from screws

WARRANTY

Congratulations! Your new instrument has been quality crafted according to quality standards and contains quality components and workmanship. It has been inspected for proper operation of all of its functions and tested by qualified factory technicians according to the long-established standards of our company.

Your instrument has a limited warranty against defective materials and/or workmanship for one-year from the date of purchase provided that, in the opinion of the factory, the instrument has not been tampered with or taken apart.

Should your instrument fail due to defective materials, and/or workmanship during this one-year period, a no charge repair or replacement will be made to the original purchaser. Please have your dated bill of sale, which must identify the instrument model number and serial number and call the number listed below:

ATP – Amprobe, TIF, Promax

Miramar, FL

Phone: 954-499-5400

800-327-5060

Fax : 954-499-5454

Website: www.amprobe.com

the local representative will assist you. Above limited warranty covers repair and replacement of instrument only and no other obligation is stated or implied.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement