DS-KIS702Y(-P)
Video Intercom Two-Wire Kit UD29996B
1
KD8003Y-IME2
Two-Wire Module Door Station
Diagram References
1
2
1
Appearance
Microphone 2
4
8
Loudspeaker 5
Two-Wire Interface
Call Button
9
6 Nametag 7 TAMPER
Module-connecting Interface 10 Terminals
Note: The module-connecting interface is used to connect other function module, such as nametag module, keypad module, card reader module, etc. All these modules are known as sub module.
Terminal
A1 NC1: Door Lock Relay Output (NC) B1 AIN2: For the access of Door Contact 2
A2 NO1: Door Lock Relay Output (NO) B2
AIN1: For the access of Door Contact 1
A3
A4
COM: Common Interface
NC2: Door Lock Relay Output (NC)
B3
B4
AIN3: For the access of Exit Button 1
AIN4: For the access of Exit Button 2
A5
A6
Low Illumination IR Supplement Light
NO2: Door Lock Relay Output (NO)
GND: Grounding
B5
B6
3 Built-in Camera
485-: Module-connecting Interface
485+: Module-connecting Interface
A7
A8
C
12 VDC: Power Output
GND: Grounding
Two-Wire Interface
B7
B8
12V OUT: Module-connecting Interface
GND: Module-connecting Interface
3
Installation
Note: Video intercom module door sta�on support one-module installa�on, two-module installa�on, threemodule installa�on and more-than-three-module installa�on. Here takes three-module installa�on as an example.
Before you begin:
1. Tools that you need to prepare for installation: Drill (6), cross screw driver (PH1*150 mm), and gradienter.
2. Make sure all the related equipment is power-off during the installation.
3. Make sure you have configured the sub module address before installation. Valid sub module address range is
1 to 8. The No. should be unique for sub modules that connected to the same main unit. The sub module address and corresponding switch status is shown as the figure.
Sub Module
Address
Module 1
Module 2
Module 3
Module 4
Module 5
Module 6
Module 7
Module 8
DIP 1 DIP 2 DIP 3 DIP 4 DIP 5 DIP 6 DIP 7 DIP 8
ON OFF OFF OFF OFF OFF OFF OFF
OFF ON OFF OFF OFF OFF OFF OFF
ON ON OFF OFF
OFF OFF ON OFF
OFF OFF OFF
OFF OFF OFF
OFF
OFF
ON OFF ON
OFF ON ON
ON ON ON
OFF
OFF
OFF
OFF OFF OFF ON
OFF OFF OFF
OFF OFF OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Three-Module Flush Mounting
1. Cave the installation hole, and pull the cable out.
Note: The suggested dimension of the installation hole is 321.8(W) × 108(H) × 45.5(D) mm. The suggested length of the cables left outside is 270 mm.
2. Select a cable entry and remove the plastic sheet. Route the cables through the gang box hole. Insert the gang box into the installation hole. Mark the gang box screw holes’ position with a marker, and take out the gang box.
3. Drill 4 holes according to the marks on the wall, and insert the expansion sleeves into the screw holes.
Fix the gang box with 4 expansion bolts.Fill the gap between the gang box and wall with concrete or Silicone sealant. Remove the mounting ears with tool after concrete is dry.
4. Connect cables and insert the modules.
a.Connect Cable 1 and one end of Cable 2 to the corresponding interfaces of the main unit, then insert the main unit into the upper grid.
b.Connect the other end of Cable 2 to the input interface of Sub Module 1. Connect one end of Sub Module
1 and insert it into the middle grid.
c.Connect the other end of Cable 3 to the input interface of Sub Module 2. Insert it into the bottom grid.
5. Fix the cover and the main unit with 2 socket head cap screws by using a hexagon wrench.
Three- Module Surface Moun�ng
1. Paste the installa�on s�cker 1 onto the wall. Make sure the s�cker is placed horizontally via measuring with the gradienter. Drill 4 holes according to the screw holes on the s�cker.
Note: The suggested size of hole is 6(diameter) × 25(depth) mm. The suggested length of the cables le� outside is 270 mm.
2. Remove the s�cker and insert the expansion sleeves into the screw holes. Fix the moun�ng frame onto the wall with 4 expansion bolts.
3. Thread the module-connec�ng line across the thread holes of the frame. Pass the main unit connec�ng line across the thread hole to the top grid and connect the cables.
a.Connect the lines and module-connec�ng line 1 to the corresponding interfaces of the main unit, then place the main unit into the upper grid.
b.Connect the other end of the module-connec�ng line 1 to the input interface of the sub modules via module-connec�ng line 2.
c.Organize the cables with cable �e in the package.
4. Insert the modules into the frame a�er wiring. The main unit must be placed in the top grid.
5. Use the hexagon wrench in the package to fix the cover onto the frame.
4
Installation Positions
Recommended Installation Height (The distance between the camera and the ground): 1.4 m to 1.6 m
The FOV of the camera is : Horizontal: 146° , Vertical: 82°.
The highest visual height and lowest visual height of the camera is shown as picture.
3
3
Note: The power source should be qualified and meet limited power source or PS2 requirements according to IEC 60950-1 or IEC 62368-1 standard.
2
Scan the QR code to get User Manual for details.
1
1
Gang Box
2
2
3 4
Main Unit
2
1
Sub Module 1
3
2
Expansion Bolt
Moun�ng Ear
3
Sub Module 2
3
4
3
2
1
Main Unit
Moun�ng Frame
Hexagonal
Screw
Module-Connec�ng
Line1
Module-Connec�ng
Line2
Thread Hole
Cables
Connected to Main
Unit
Cover
Sub Module
Hexagonal
Screw
5
5
Hexagon Wrench
4
Recommended Installation Height (The distance between the camera and the ground): 1.4 m to 1.6 m
1.4 m
1.5 m
DS-KH6320Y-WTE2
Video Intercom Two-Wire Indoor Station
Diagram References
1 Appearance
1
4
5
Display Screen
Loudspeaker
2
Two-Wire Interface
6
Microphone
TF Card Slot
3 Debugging Port
7
Note: The debugging port is used for debugging only.
Alarm Terminal
2
Wiring
There are 20 pins in the terminal on the rear panel of the indoor station: 2 RS-485 pins, 5 reserved pins, 4 relay output pins, 8 alarm input pins, and 1 GND pin.
Wire the devices with power supply cables.
Caution: Make sure all the related equipment is power-off during the installation.
Note: The power output of the indoor station is 24 VDC, 4 W.
1
3
Installation
The wall mounting plate and the junction box are required to install the indoor station onto the wall.
The dimension of junction box should be 75 mm (width) × 75 mm (length) × 50 mm (depth).
The dimension of wall mounting plate is shown.
Before you begin:
1. Tools that you need to prepare for installation: Make sure the device in the package is in good condition and all the assembly parts are included.
2. The power supply the indoor station supports is 24 VDC. Please make sure your power supply matches your indoor station.
3. Make sure all the related equipment is power-off during the installation.
4. Check the product specification for the installation environment.
Wall Mounting with Junction Box
1. Chisel a hole in the wall. The size of the hole should be 76 mm (width) × 76 mm (length) × 50 mm (depth).
2. Insert the junction box to the hole chiseled on the wall.
3. Fix the wall mounting plate to the junction box with 2 screws.
4. Hook the indoor station to the wall mounting plate tightly by inserting the plate hooks into the slots on the rear panel of the indoor station, during which the lock catch will be locked automatically.
4
Getting Started
1
Activate Indoor Station
You are required to activate the device first by setting a strong password for it before you can use the device.
1. Power on the device. It will enter the activation page automatically.
2. Create a password and confirm it.
3. Tap OK to activate the indoor station.
2
Quick Configuration
• After Activation, you can follow the wizard to complete quick configuration, including language settings, network settings, indoor station settings, linked devices settings, etc.
• If you want to enter the wizard page, you can tap Settings → admin (activation) password. Tap
→ Configuration, and enter the to enter the system maintenance page.
3
Refer to Video Intercom Indoor Station Configuration Guide (scan the QR code) for details.
Refer to Video Intercom Indoor Station Operation Guide (scan the QR code) for details.
DS-KAD704Y
Video Intercom Two-Wire Video/Audio Distributor
E N G L I S H
Diagram References
1 Appearance
1 Power Indicator
5 Cascade Network Indicator
2 Cascade Interface
6 Network Indicator
3 Terminals
7 Power Input
4 LAN
8 Reset
2
Wiring
Wire the devices with power supply cables.
Door station should be connected to CH4 of the video/audio distributor with two-wire cables.
Indoor Station should be connected to any terminal of CH1 to CH3 of the video/audio distributor with twowire cables.
Caution: Make sure all the related equipment is power-off during the installation.
Note: The power output of CH1 to CH3: 12 VDC, Max. 4W. The power output of CH4: 24 VDC, Max. 8W.
1
3
Installation
Before you begin:
Make sure the device in the package is in good condition.
Make sure all the related equipment is power-off during the installation.
Check the product specification for the installation environment.
1. Fix the DIN rail onto the wall.
Note: You are required to utilize a matched DIN rail.
2. Press the red clip upward, and lock it to the DIN rail.
1
2
IN OUT
MAX
4W
24VDC
3
MAX
8W
IN OUT
4 5 6 7
8
3
MAX
4W
24VDC
MAX
8W
2 2
Indoor Station
Door Station
IN OUT
MAX
4W
24VDC
MAX
8W
IN OUT
Video/Audio Distributor
24 VDC
Power Input
Note:
The power adapter is contained only in the
DS-KIS702Y-P
Kit.
The detail for the power adapter contained in the package is as follows:
Model
KPL-060M-II
Manufacturer
Channel Well Technology Co., Ltd
MAX
4W
24VDC
MAX
8W