CMP Galaxy Pool Drain Instructions
The CMP 25515-00X-000 is a pool drain with a sump, designed for use in vinyl pools. It features a flow rate of 112 GPM for floor installations and 84 GPM for wall installations, ensuring efficient water drainage. The drain cover has a 7-year lifespan, while the sump body lasts up to 30 years. It can be plumbed with either the bottom or side port, and comes with plugs for the unused port. This drain is part of a multiple drain system and should not be used as a single drain.
Advertisement
Advertisement
®
GALAXY POOL DRAIN WITH SUMP
25514-00X-000, 25515-00X-000, 25516-00X-000, 25519-00X-000
VGBA TESTED & CERTIFIED
ANSI-APSP 16 | CPSC
All Custom Molded Products main drains are listed and tested in strict accordance to the requirements of ANSI/APSP - 16 2017, the current standard of reference for the Virginia Graeme Baker Act, and compliant to the latest Consumer Product
Safety Commission (CPSC) requirements.
For Multiple Drain Use Only | Submerged | Cover Life: 7 Years | Floor or Wall
IAPMO Listed VGB Suction: Compliant to ANSI/APSP - 16 2017 & CPSC
Requirements
TABLE OF CONTENTS
Please read through the entire manual before installing your new unit. Your pool drain fitting must be installed and operated as specified.
A. Safety Instructions & Precautions .........................................................................................
3
B. Sizing & Specification Reference ..........................................................................................
4
C. Installation & Maintenance Procedures ..............................................................................
5
1. Required for Installation ......................................................................................
5
2. Installation Location ............................................................................................
3. Installation Procedure .........................................................................................
4. Maintenance & Inspection ................................................................................
5 . Winterizing .............................................................................................................
5
5
7
7
D. Diagram & Measurements ......................................................................................................
8
E. Parts List .........................................................................................................................................
9
IMAGES & TABLES IN THESE INSTRUCTIONS page 4 FLOW RATES page 4 page 4
SPECIFICATIONS
HEAD LOSS CHART page 6 page 6 page 8
INSTALLATION LOCATION
ALTERNATE PLUMBING
DIMENSIONS
2
A. SAFETY INSTRUCTIONS & PRECAUTIONS
When installing and using this equipment, basic safety precautions shall always be followed, including the following:
IMPORTANT SAFETY INSTRUCTIONS.
READ, UNDERSTAND AND FOLLOW ALL INSTRUCTIONS.
WARNING
WARNING
NOTICE
WARNING
NOTICE
NOTICE
NOTICE
WARNING
NOTICE
WARNING
NOTICE
When using two or more suction fittings on a common suction line, suctions must be separated by a minimum of 3 ft or they must be located on two different planes.
WARNING: DO NOT locate suction outlets on seating areas or on backrests for such seating areas.
Attention Installer: This manual contains important information about the installation, operation and safe use of this product. Before installing this product, read and follow all warning notices and instructions which are included. This information should be given to the owner and/or operator of this equipment.
To reduce the risk of drowning from hair and body entrapment, install suction fittings with a marked flow rate in gallons per minute that exceeds the flow rate of your system by at least 25%. Always use multiple suction outlets. If the fitting/cover breaks, is damaged, or is missing, shut the system down immediately. Do not use the system until damaged parts have been replaced.
Keep hair and clothing a minimum of 12 inches from all suction fittings and drains at all times. Persons with long hair should secure hair to a minimal length or wear swimming cap. Children should never be left unattended at any time in a swimming pool, spa, or bathtub. Be sure the temperature of the water never exceeds the manufacturer’s recommendations.
To reduce the risk of injury, installation and service should be done by a qualified Service Professional, certified electrician or authorized CMP representative.
NOTE: In the event that one suction outlet is completely blocked, the remaining suction outlet(s) serving that system
MUST have a flow rating capable of the full flow of the pump(s) for the specific suction system.
Increasing size of the pump may increase flow rate of suction beyond rated safety limits causing entrapment or death.
All Suction Outlet Fitting Assemblies (SOFAs) shall be installed in accordance with the manufacturer’s installation instructions, or for Registered Design Professional SOFAs, in accordance with the registered design professional’s engineering plans. Field modification made to a SOFA not authorized by the manufacturer’s installation instructions shall void the SOFA certification.
Hair or body parts blocking the spa or pool suctions may become trapped and held against the suction fitting.
Entrapment against the suction fittings can result in drowning or other severe injury. Never sit on or lean up against suction fittings. Never exceed the maximum allowable flow rate stated on the suction fitting. The suction fitting and fasteners should be inspected for damage or tampering before use. Missing, broken, or cracked suction fittings shall be replaced. Loose suction fittings shall be reattached or replaced before use of this facility.
The maximum hose length difference between any self-contained SOFA and the tee leading to the pump shall not exceed 13 feet (3.96 m).
NOTICE CMP drain covers are only certified for use with CMP sumps and frames. Do not mismatch with parts from other manufacturers.
SAVE THESE INSTRUCTIONS
3
B. SIZING & SPECIFICATION REFERENCE
• Suction fitting configuration specific flow ratings MUST NOT be exceeded at any time the pool is open to bathers.
• A system must install a suction fitting, or combination of multiple suctions, such that the resulting individual suction system flow rating is greater than the pumping system’s maximum system flow rate.
• To reduce the risk of drowning from hair and body entrapment, install suction fittings with a marked flow rate in gallons per minute that exceeds the flow rate of your system by at least 25%. Increasing size of the pump may increase flow rate of suction beyond rated safety limits causing entrapment or death.
• Any modification that increases the flow rate of the circulation system shall require reevaluation of the cover/grate and sump to ensure that the flow rating of the Suction Outlet Fitting Assembly is not exceeded.
• The flow rating for pools with multiple, blockable SOFAs piped together in one body of water without isolation valves shall be determined by combining the flow rating of all SOFAs, minus the flow rating of one. If the flow ratings of all SOFAs are not equal, subtract the flow rating of the SOFA with the highest flow rating.
• NOTICE: No modification shall be made to a SOFA structure or flow path unless the new configuration has been certified as new SOFA.
TABLE 1: IAPMO LISTED MAX FLOW RATES
PLUMBING SIZE
2”
2”
1.5”
1.5”
PORTS FLOOR FLOW RATE
BOTTOM
SIDE
BOTTOM
SIDE
112 GPM
112 GPM
108 GPM
100 GPM
FLOW RATE VERIFIED TO CPSC TEST PROTOCOL
WALL FLOW RATE
92 GPM
84 GPM
84 GPM
84 GPM
TABLE 2: SPECIFICATIONS
PIPE SIZE
GUNITE - 2" FPT (ADAPTABLE TO 1.5")
VINYL - 2" FPT OR 2” SOCKET (ADAPTABLE TO 1.5”)
DO NOT adapt suction fitting to any pipe size smaller than ASTM 1.5" SCH 40 PVC.
OPEN AREA 13.2in
2
DRAIN COVER LIFE
SUMP BODY LIFE
• Multiple drain use ONLY
• Floor or wall installation
7 Years. Replace drain cover and screws every seven years.
30 Years
• PVC Sump Body. Use PVC glue to attach plumbing fittings.
0.5
0
-0.5
0
2
1.5
1
3.5
3
2.5
0.81
-0.43
20
1.14
0.16
1.51
0.83
2.28
2.18
120
3.11
3.24
140 40
1.5IN PIPE
60
FLOW RATE (GPM)
80
CHART 1: HEAD LOSS CHARTS
100
2IN PIPE
4
C. INSTALLATION & MAINTENANCE
1. REQUIRED FOR INSTALLATION
Your Galaxy Drain includes the following:
• Drain Sump Body
• Drain Suction Cover
• Cover Screws
• 2" NPT Plugs (2)
• Protective Plaster Installation Cover (gunite models only)
• Vinyl Ring & Gaskets (vinyl models only)
• 2" to 1.5" FPT Bushings (if threaded model)
2. INSTALLATION LOCATION
a. This suction fitting is designed for installation on the floor or wall of hot tubs or pools. 25515 models are intended for vinyl pools. 25514, 25516, 25519 models should be installed in gunite pools.
b. Do not mount directly under seats. c. Always use multiple suction outlets. DO NOT use with single drain applications. Use with single drain applications will void any and all warranties. Single drain installation increases the risk of entrapment against the suction fittings , which can result in drowning or other severe injury. Blockable SOFAs shall be installed in a multiple SOFA system only.
d. When using two or more suction fittings on a common suction line, suctions must be separated by a minimum of 3 ft or they must be located on two different planes.
SAFETY CHECKLIST: e. Suction fitting and fasteners should be observed for damage or tampering before each use. f. DO NOT adapt suction fitting to any pipe size smaller than ASTM 1.5” SCH 40 PVC. g. Missing, broken, or cracked suction fittings shall be replaced before use. Loose suction fittings shall be reattached or replaced before use.
3. INSTALLATION PROCEDURE
PLUMBING: a. Install sump in floor or wall. If the sump is installed in the pool/spa floor, install in the center of the pool/spa OR the deepest point.
b. Cover/grates, when installed, shall not protrude more than 2 in. (51 mm) from the finished surface of the pool in which the
SOFA is installed.
c. Drain ports are for 2 inch plumbing and can be adapted to 1.5 inch. d. Plumb with either the bottom port OR side port. Plug the unused port with the included plug.
e. Maximum flow rates will vary depending on plumbing option chosen. See Table 1 for details.
GUNITE INSTALLATION: f. IMPORTANT! Leave the protective cover in place until plaster installation is complete. Use included cover screws to attach protective cover during installation.
g. Finish pool with gunite/shotcrete and plaster so that it is completely level with the sump body and cover. Ensure the finish is completely level. Pool finish should not exceed the top of the sump.
h. Remove the protective cover.
i. When any SOFA component is held in place by the interior finish of the pool, that surface shall be free of deterioration and voids.
j. Attach cover/grate with the supplied screws. Verify that the suction cover is properly tightened with the #8 316 stainless steel screws in brass inserts to 14in-lbs. DO NOT over-torque the cover screw. Excessive torque can cause premature failure of threads or damage to suction fitting increasing risk of entrapment. Start install of screws by hand to ensure proper thread engagement and to prevent cross threading. DO NOT USE POWER TOOLS TO INSTALL FASTENERS.
5
C. INSTALLATION & MAINTENANCE
VINYL INSTALLATION: a. Finish pool surface so that it is completely level with the sump body and cover. Pool finish should not exceed the top of the sump.
b. Place gasket on sump body, making sure holes in gasket align with holes in sump flange (a very light application of silicone will help hold the gasket in place).
c. Install liner before proceeding to next step. Follow pool manufacturer’s instructions for proper vinyl liner installations.
d. Align second gasket and vinyl ring outside the vinyl liner. Pierce vinyl liner through vinyl ring holes one at a time before inserting screws. Screws must go through ring, gasket, liner, second gasket and into sump. Verify that the vinyl ring is properly tightened with the stainless steel screws in brass inserts to 24in-lbs.
e. Cut out liner along inside edge of vinyl ring.
f. When any SOFA component is held in place by the interior finish of the pool, that surface shall be free of deterioration and voids.
g. Attach cover/grate with the supplied screws. Verify that the suction cover is properly tightened with the #8 316 stainless steel screw in brass inserts to 14in-lbs. DO NOT over-torque the cover screw. Excessive torque can cause premature failure of threads or damage to suction fitting increasing risk of entrapment. Start install of screws by hand to ensure proper thread engagement and to prevent cross threading. DO NOT USE POWER TOOLS TO INSTALL FASTENERS.
SOFA components and fastener receptacles shall be clean and free of debris or obstructions during installation of cover/grate and fasteners. The use of adhesives or other attachment methods that prevent access to suction piping or SOFA components requiring periodic servicing is prohibited. Hand-check cover/grate for snugness to the sump/ frame after installation.
MIN 3 FT OR DIFFERENT PLANES
Gunite/
Shotcrete
Plaster/Pool Finish
Threaded Plug
Earth/
Substrate
IMAGE 1 - INSTALLATION - BOTTOM PORT
Install Ring
Vinyl
Liner
Gaskets
SIDE PORT
Threaded Plug
VINYL LINER
IMAGE 2 - ALTERNATE INSTALLATIONS
6
C. INSTALLATION & MAINTENANCE
FIELD BUILT SUMP INSTALLATION: h. Refer to TABLE 1 for flow rates i. Minimum Pipe Depth (A) Side Port: 1-3/4in; Bottom Port: 4-3/4in j. Ledge Width (B): 1-1/8in k. Minimim Pipe Length Before Pipe Size Reduction: 8.5in
l. For additional information on proper drain installation refer to The Association of Pool & Spa Professionals ANSI/APSP/
ICC-7 2013 Standard and the Virginia Graeme Baker Pool & Spa Safety Act (VGB Act).
B B
Flow P ath Boundar y
A
Flow P ath Boundar y
A
IMAGE 3 - FIELD BUILT SUMP DIMENSIONS
2. MAINTENANCE & INSPECTION
a. Covers/grates and all other SOFA components shall be replaced before the end of their service life. Service life begins the month and year in which a SOFA component is installed with or without water. The cover/grate and screws should be replaced at least every seven (7) years. Sump and frame service life is 30 years.
b. Inspect pool or spa regularly to ensure that the drain cover/grate is in place and secure.
c. Missing, broken, or cracked SOFA components shall be replaced before bathers are allowed to use the pool or spa. Loose covers/grates shall be reattached before bathers are allowed to use the pool or spa. d. If the cover is found with color changed, broken, cracked, missing, brittle components with chunks or pieces broken off, it must be replaced. Do not use the pool/spa/facility until a replacement is made.
e. If there are stripped screw holes or if the brass insert receptacles are missing/removed, the SOFA must be replaced. Do not use the pool/spa/facility until a repair or replacement is made.
f. If a drain cover/grate does not pass inspection:
• Close the pool or spa immediately
• Post a closure notice
• Keep the facility closed until a new drain cover and screws are properly installed.
3. WINTERIZING
• Requirements for winter will vary depending on region - follow normal winter and freeze protection practices for your area.
• For areas that require partial drainage and/or clearing lines to prevent freeze damage:
• If your suction(s) have a dedicated suction line: Use a blower to clear the suction line of water and cap or close the line with a valve to prevent freeze damage.
• If your suction(s) are connected to a skimmer/equalizer line: Follow skimmer winterization procedures. Optionally blow and cap the suction line or fill line with foam rope/backer rod to protect from freeze damage.
7
D. PART DIAGRAMS AND MEASUREMENTS
0.98”
8.5”
7.7”
6.4”
GALAXY MAIN DRAIN
IMAGE 4 - DIMENSIONS
DEEP BODY
8
G. PARTS LIST
1
2
4
5
5
6
3
4
4
4
1
2
3
3
1
1
1
4
3
CMP P/N
61050-550-250
61051-052-028
61004-083-212
61051-058-030
25507-100-010*
25520-050-010
25520-040-010
25520-020-000
25514-000-020
25515-010-010
25516-000-010
25519-010-010
25532-800-000
25532-801-000
25515-000-011
Parts numbers not listed in product table are only available as part of a complete assembly.
*See c-m-p.com or pool products catalog for other color and kit options
DESCRIPTION
SCREWS FOR 25514
SCREWS FOR 25515
SCREWS FOR 25516
SCREWS FOR 25519
COVER
PLUG FOR 25514, 25516
PLUG FOR 25515
PLUG FOR 25519
SUMP - 25514 MODELS
SUMP - 25515 MODELS
SUMP - 25516 MODELS
SUMP - 25519 MODELS
VINYL ADAPTER RING, WHITE
VINYL ADAPTER RING, GRAY
VINYL GASKETS (2 REQUIRED)
5
6
9
10
Record Information on this System Below & Keep for Your Records
Installer _______________________________________________________________
Purchased From _______________________________________________________
Installation Date _____________________________
Model Number ______________________________
Pool Size in Gallons __________________________
CMP Customer Service & Tech Support
Toll Free: 1-800-733-9060
FAX: 770-732-7115 [email protected]
Warranty Questions
[email protected]
Support Resource & Videos Online c-m-p.com/resourcecenter
11
1021sb CUSTOM MOLDED PRODUCTS | 36 HERRING ROAD, NEWNAN, GA 30265 | WWW.C-M-P.COM

Public link updated