Axess X Wireless Series Installation Manual
PDF
Document
Advertisement
Advertisement
Installation Manual Thank You For Choosing IDS to Protect You Congratulations on your purchase of an IDS X-series alarm panel with aXess integration. IDS X-series panels are powerful, versatile and highly configurable security systems, which should be installed by a professionally trained installer. This aXess Installation manual covers the aXess installation information and is not a complete X-Series guide. The majority of panel features are programmable only by an IDS-accredited installer in possession of the INSTALLER CODE. For information on programming the X-Series Alarm panel please refer to the appropriate manual. All user manuals can be downloaded from www.idsprotect.com. Installer manuals can be downloaded if you are registered with IDS as a company and have created an account on the website. Features Controls up to 8 doors Arm/Disarm the X-Series alarm via an access control tag (Hold tag for 3 seconds on the reader) Deny access if the alarm is armed Forced door alarm Fire doors Access areas even if disconnected from the X-Series alarm panel Readers can be configured to be Arm/Disarm only, Access Only or both Transactions can be viewed from the keypad Introduction aXess is the perfect way to extend the functionality of an alarm panel by including access control for up to eight doors. Each door has an interface that can be installed in two configurations: 1. Two readers: one on each side of the door for entry and exit. 2. One reader: one for entry and a push button for exit. Access tags can be linked to alarm codes to be able to arm and disarm the alarm. Clear Interface Memory When powering up for the first time and the aXess readers do not show the correct LEDs short the “RESET” jumper (see fig 3) for three seconds. Installer Mode Note: Only LCD keypads can be used to program aXess locations Location 259 has been set aside for access control configuration. Enter ‘Installer Mode’ and location [9][9][9][9][*] Enter location [2][5][9][*] Enrolling Doors This sub location is to identify each door to the alarm system and allocate each door with a number. Use the scroll button to scroll to “Enrol Door”. Enter [door number][*] Swipe card (Any card, learnt or not, to identify the physical reader to the system) Remove Door Use the scroll button to scroll to “Remove Door”. Enter [door number] [*] Door Configuration This sub location is to allocate each door to a partition, to set the lock strike time in milliseconds, and to set a zone number if the door is to be monitored for forced/propped door and will operate as a normal alarm zone on the panel. Use the scroll button to scroll to “Config Door” Enter [door number][*] Enter [partition number][*] Enter strike time in milliseconds [ms] [*] Enter [zone number] [*] - this is optional. If used, 'Door Switch enabled' must be 'Y' in the Advanced Door Configuration. X-Series aXess 700-560-01E Advanced Door Configuration Use “Advanced configuration” to enable or disable certain permissions, access types, and door settings. Use the scroll button to scroll to “Config Door Adv” Enter [door number][*] Select the door’s options shown in the table below by scrolling and pressing [*] to enable ‘Y’ or disable ‘N’ Table 1: Door Configuration Opt 1 2 3 4 5 6 7 8 9 Description Door Switch enabled Silence the reader Deny entry if armed Enable as an Arm reader to arm/disarm the alarm Enable as an Access reader Fire door Allow access if interface is disconnected from the system Enable/Disable Door left Open Beep Enable/Disable forced door monitoring Default N N N N Y Y N Y Y Door Switch Enabled – Enable this setting if a door contact is installed and you want to allocate a zone to the door to monitor the door for forced open or held open situations. Deny Entry if Armed – When enabled this option will disable the system from allowing anybody access through the door if the door is allocated to the armed partition. Arm/Disarm Reader – When enabled this option allows a tag allocated to an arm/disarm user code to arm or disarm the system, depending on the state of the alarm, by holding the tag for three seconds in front of the reader. Access Reader – When disabled the reader will not function as an access reader. If the reader is an arm/disarm reader and access is disabled it will allow the alarm to be armed or disarmed. Note: The tag must have been allocated a valid alarm user code (defined below). The user code properties will define the mode or type of arming. Fire Door – If a door is enabled as a fire door and a fire alarm is triggered all fire doors will automatically unlock Off Line Mode – if the interface loses communication with the panel due to a break in the communications bus line, it will continue to operate as an access reader, but arm / disarm functionality will be disabled, and arm status will not be shown. Door Left Open Beep – If the door is monitored by a door magnet (Door Switch must be enabled) and left open for 30 seconds the reader will beep for 15 seconds to draw attention to the door being open. Disable if this feature is not required Forced Door Monitoring – This feature will raise an alarm if the door is opened without presenting an authorised tag first. Door contact must be enabled and configured. Master User Menu Enter “Master User” menu: Hold down [*] until beep Enter Master user code [1] [2] [3] [4] [*] aXess control menus are: o Menu 32 “Add/Edit Card” by typing in the tag number o Menu 33 “Add/Edit Card” by Swiping the tag o Menu 34 “ Delete Card” o Menu 35 “Delete Card by swipe” o Menu 36 “View Transactions” Option 32: Adding Access Tags Menu option 32 allows the adding of access tags to the system or the editing of existing tags. The procedure to add a tag is to enter the tag’s number, allocate it to a user code and any of the eight doors where the tag may be presented. Enter [3] [2] [*] o Enter the [card number] [*] o Select the doors by entering the [door number] [*] to enable ‘Y’ and by entering the [door number] [*] to disable ‘-’ X-Series aXess 700-560-01E Door Selection Table 2: Door Selection Door 1 2 3 4 5 6 7 8 Default Y o To select a door number press the number on the keypad followed by [*] o Once all selections are made press [*] to exit door/arm selection o Enter [user code] then [*]. (If no user code press [*] Option 33: Adding Access Tag by swiping the tag Menu option 33 allows the adding of access tags to the system or the editing of existing tags by swiping the tag. The procedure to add a tag is to swipe the tag on a reader, allocate it to a user code and any of the eight doors the system is monitoring. Enter [3] [3] [*] o Enter the [Door No] [*] that will be used to swipe the tag o Swipe card, if card number is correct, [*] o Select the doors by entering the [door number] [*] to enable ‘Y’ and by entering the [door number] [*] to disable ‘’. See Table 2 Door selection o Once all selections are made press [*] to exit door/arm selection o Enter [User Code] then [*]. (If no user code press [*]) Option 34: Deleting Access Tags This menu option allows the user to remove a card from the reader Enter [3][4][*] o Enter the [card number][*] to delete the tag Option 35: Delete Access Tags via Swipe This menu option allows the user to remove a card from the reader if the card is available Enter [3][5][*] o Enter the door number that the action will be carried out o Swipe the card to be deleted Option 36: View Transactions This menu option allows the master user to view the log of transactions for a specific door. The most recent transaction logged will be the first event displayed. To view older transactions the back scroll button can be used and once you have scrolled back the forward scroll button can be used to go forward to the most recent entry. The keypad will give an error beep if there are no transactions or the last recorded one has been reached. Enter [3][6][*] o Enter the door [number] of the transactions you want to view followed by [*] Reader Feedback Each access reader has three different colour LEDs, Red, Yellow, Green and a buzzer to communicate feedback to users of the system depending on the type of reader Figure 1: aXess Reader LEDS Green Red Yellow X-Series aXess 700-560-01E Arming Only Reader Table 3: Arming Only Reader LEDs Action Description.... ARMING ONLY READER Red Yellow Green Beeper Factory Reset All 3 LED's flashing in sync None Enrol Mode Flashing in sync with Green LED Flashing out of sync with Red/Green LED's Flashing in sync with Red LED Single beep when any tag swiped Idle Following Partition's ARM LED ON if comms to panel is good. Following Partition's READY LED None Learn Tag Mode Following Partition's ARM LED ON if comms to panel is good. Flashing Single beep when tag swiped Door Forced Following Partition's ARM LED ON if comms to panel is good. Following Partition's READY LED Failed Beep (if door switch connected and configured) Door Left Open Following Partition's ARM LED ON if comms to panel is good. Following Partition's READY LED Door Left Open Beep (if door switch connected and configured) Tag held in field (Arming Time) Following Partition's ARM LED Slow Flash Following Partition's READY LED None Access Only Reader Table 4: Access Only Reader Action Description.... ACCESS ONLY READER Red Yellow Green Beeper Factory Reset All 3 LED's flashing in sync Enrol Mode Flashing in sync with Green LED Flashing out of sync with Red/Green LED's Flashing in sync with Red LED Single beep when any tag swiped Idle Following Partition's ARM LED ON if comms to panel is good. Following Relay None Learn Tag Mode Following Partition's ARM LED ON if comms to panel is good. Flashing Single beep when tag swiped Following Partition's ARM LED ON if comms to panel is good. Following Relay (On whilst Relay is On Strike Time) Single beep when valid tag swiped Solid On for 2s ON if comms to panel is good. Off Failed Beep Solid On for 2s ON if comms to panel is good. Off Failed Beep (if door switch connected and configured) Following Partition's ARM LED ON if comms to panel is good. Off Door Left Open Beep (if door switch connected and configured) Access Granted (Relay On) Access Denied Door Forced Door Left Open Tag held in field (Arming Time) None Not Available X-Series aXess 700-560-01E Access & Arming Reader Table 5: Access & Arming Reader Action Description.... ACCESS & ARMING READER Red Yellow Green Beeper Factory Reset All 3 LED's flashing in sync Enrol Mode Flashing in sync with Green LED Flashing out of sync with Red/Green LED's Flashing in sync with Red LED Single beep when any tag swiped Idle Following Partition's ARM LED ON if comms to panel is good. Following Relay None Learn Tag Mode Following Partition's ARM LED ON if comms to panel is good. Flashing Single beep when tag swiped Following Partition's ARM LED ON if comms to panel is good. Following Relay (On whilst Relay is On Strike Time) Single beep when valid tag swiped Solid On for 2s ON if comms to panel is good. Off Failed Beep Solid On for 2s ON if comms to panel is good. Off Failed Beep (if door switch connected and configured) and XSeries will go into alarm Door Left Open Following Partition's ARM LED ON if comms to panel is good. Off Door Left Open Beep (if door switch connected and configured) Tag held in field (Arming Time) Following Partition's ARM LED Slow Flash Following Relay None Access Granted (Relay On) Access Denied Door Forced None Diagrams Figure 2: Interface Inputs Wiring Diagram X-Series aXess 700-560-01E Figure 3: Tag Reader Wiring Diagram Figure 4: Jumpers Mode Jumper Used if Wiegand device attached Term Jumpers Do not short Reset Jumper Clears all memory X-Series aXess 700-560-01E X-Series aXess 700-560-01E ">

Download
Just a friendly reminder. You can view the document right here. But most importantly, our AI has already read it. It can explain complex things in simple terms, answer your questions in any language, and help you quickly navigate even the longest or most compilcated documents.
Advertisement