WESTERSTRAND
1632en03.doc
CAn
2003-09-03
1 of 12
User manual
Quartz master clock
WDP-Y mini
121346-00
R
F
P
L N
General
Options
2
2
Installation
3
Configuration
DCF synchronisation
RDS/GPS synchronisation
Minute impulse synchronisation
4
4
4
4
Programming
General
Functions
Manual control
Set time– function F1
Set slave clock time– function F2
Relay output programming – function F3
Relay impulse length programming – function F4
Setting of impulse length for slave clock output – function F5
Setting of synchronisation source – function F6
5
5
5
5
6
7
8
9
9
10
Special functions
Program reset
10
10
Technical data
11
Programming form
12
WESTERSTRAND URFABRIK AB
Box 133
SE-545 23 TÖREBODA
Tel. +46 506 48000
Fax. +46 506 48051
Internet::
e-mail:
http://www.westerstrand.se
[email protected]
Document:
Author:
Date:
Page:
WESTERSTRAND
1632en03.doc
CAn
2003-09-03
2 of 12
General
Quartz master clock WDP-Y mini with impulse output for operation of slave clocks.
The clock has a programmable relay output for control of, for example, illumination or pause signals.
The relay output can be programmed with 40 different ”signal points”.
A built-in temperature compensated quartz crystal oscillator gives high accuracy also when the ambient
temperature is varying. Optional time signal receivers can be connected for extra high accuracy. Minute impulse
synchronisation is also possible.
Changing from winter time to summer time and vice verse is fully automatic and does not need programming.
In case of power failure, an internal memory keeps the correct time for 24 hours.
Note: Activation or deactivation of the relay is not possible during power failure.
The connected slave clocks are corrected after the power failure by means of rapid impulsing.
The impulse output has a short-circuit protection with automatic reset.
In the event of short-circuit, the alarm LED is lit and outgoing impulses are inhibited.
R
F
P
Programming buttons
L N
+ -
Configuration switches for synchronisation
Connection minute impulse out
Connection synchronisation
Relay output
Connection 230VAC
Options
The following options can be used:
• Synchronisation DCF, art. no. 122984-20
• Synchronisation RDS, art. no. 122983-00
• Synchronisation GPS, art. no. 122982-00 (factory mounted option)
WESTERSTRAND URFABRIK AB
Box 133
SE-545 23 TÖREBODA
Tel. +46 506 48000
Fax. +46 506 48051
Internet::
e-mail:
http://www.westerstrand.se
[email protected]
Document:
Author:
Date:
Page:
WESTERSTRAND
1632en03.doc
CAn
2003-09-03
3 of 12
Installation
The master clock is intended for wall mounting.
The connectors are removable for easier installation.
•
•
•
•
•
Mount the master clock with four screws.
Connect the wires for the outgoing minute impulse.
Connect the synchronisation source, if any. Check the
configuration switches before any synchronisation source is
connected. The master clock may be damaged if the wrong
setting is used. See ”Configuration” below.
Connect the wires for the relay output.
Connect the wires for 230VAC. When the clock is
permanently installed, a readily accessible disconnect
device shall be incorporated in the fixed wiring.
Installation fuse max. 10A.
Supply wire area: 1,5mm2.
100
Ø4
145
WESTERSTRAND URFABRIK AB
Box 133
SE-545 23 TÖREBODA
Tel. +46 506 48000
Fax. +46 506 48051
Internet::
e-mail:
http://www.westerstrand.se
[email protected]
Document:
Author:
Date:
Page:
WESTERSTRAND
1632en03.doc
CAn
2003-09-03
4 of 12
Configuration
The master clock can be synchronised via minute impulse or radio DCF/RDS. This must be selected with the
switches at the edge of the front panel. Furthermore, correct type of synchronisation must be selected with
function F6; see “Programming”.
Note: The master clock may be damaged if the switches are in the wrong position.
DCF synchronisation
Set the switches like this:
(2-wire)
+
RDS/GPS synchronisation
(GPS: The master clock must be prepared for GPS from factory)
Set the switches like this:
(3-wire)
+
DCF
Minute impulse synchronisation
Set the switches like this:
Minute impulse
sync
WESTERSTRAND URFABRIK AB
Box 133
SE-545 23 TÖREBODA
Tel. +46 506 48000
Fax. +46 506 48051
Internet::
e-mail:
http://www.westerstrand.se
[email protected]
Document:
Author:
Date:
Page:
WESTERSTRAND
1632en03.doc
CAn
2003-09-03
5 of 12
Programming
General
Use the buttons R, F and P to program the clock.
R
F
P
Return
Function
Programming
Return to normal mode
Select function/Accept
Change/Select.
The buttons are self-repeating if pressed for more than 0,7 s.
A total of 40 different signal points can be programmed. A signal point is a programming of the relay output at a
certain time and with a certain signal type, e.g. switch ON at 07.00 on Mondays.
Functions
Select with button F:
F1
F2
F3
F4
Set time
Set slave clock time
Relay programming
Impulse length for the relay output. This setting is relevant only when the output is programmed for
“Pulse” (1-59 sec).
F5 Set impulse length for the outgoing minute impulse (0,5-4,0 s.)
F6 Select synchronisation source (minute impulse or DCF)
Abbreviations used in the programming menus:
y
n
d
H
n
S
P
S
E
0
1
P
W
year
month
day
hour
minute
second
program no.
signal type
erased signal point
switch OFF
switch ON
pulse
weekday
(relay contact open)
(relay contact closed)
(the relay is activated for a programmed time, 1-59 sec)
Manual control
With the clock in normal mode, the relay can be controlled manually by pressing button ”P”.
WESTERSTRAND URFABRIK AB
Box 133
SE-545 23 TÖREBODA
Tel. +46 506 48000
Fax. +46 506 48051
Internet::
e-mail:
http://www.westerstrand.se
[email protected]
Document:
Author:
Date:
Page:
WESTERSTRAND
1632en03.doc
CAn
2003-09-03
6 of 12
Set time– function F1
Note! The complete routine must be worked through.
- - - -
F1
Press ”R” to enter normal mode. If time is not previously set, ”----” is
shown in the display. Press F until ”F1” is shown.
Function for programming of time. Select with P.
y
00
Year. Change with P. Accept with F.
n
01
Month. Change with P. Accept with F.
d
01
Date. Change with P. Accept with F.
H
00
Hour. Change with P. Accept with F.
n
00
Minute. Change with P. Set time one minute ahead of correct time and
await the minute shift. Press F to synchronise.
F1
Press R to return to or continue with next function (press F).
WESTERSTRAND URFABRIK AB
Box 133
SE-545 23 TÖREBODA
Tel. +46 506 48000
Fax. +46 506 48051
Internet::
e-mail:
http://www.westerstrand.se
[email protected]
Document:
Author:
Date:
Page:
WESTERSTRAND
1632en03.doc
CAn
2003-09-03
7 of 12
Set slave clock time– function F2
23.59
F2
When the clock is in normal mode, press F to select function F2.
Function for correction of slave clocks. Select with P.
Note: Set the time shown by the slave clocks. The time of the slave clock
is automatically adjusted by rapid impulses or by inhibition of impulses.
H
00
Hour. Change with P. Accept with F.
n
00
Minute. Change with P. Accept with F.
F2
Press R to return or continue with the next function (press F).
Note: If the slave clock is one minute from correct time, reverse the slave clock connection wires.
WESTERSTRAND URFABRIK AB
Box 133
SE-545 23 TÖREBODA
Tel. +46 506 48000
Fax. +46 506 48051
Internet::
e-mail:
http://www.westerstrand.se
[email protected]
Document:
Author:
Date:
Page:
WESTERSTRAND
1632en03.doc
CAn
2003-09-03
8 of 12
Relay output programming – function F3
23.59
F3
When the clock is in normal mode, press F to select function F3.
Relay programming. Select with P.
P
01
S
E
Signal point (program) 1. Change with P. Accept with F.
A total of 40 different signal points can be programmed.
Signal type. Change with P.
Select one of the following:
E
0
1
P
erased signal point
switch OFF
switch ON
pulse
Accept with F.
W
0
Weekday. Change with P.
Select one of the following:
1
2
3
4
5
6
7
8
9
0
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Monday-Friday
All days in week
Saturday-Sunday
Accept with F.
H
00
Hour. Change with P. Accept with F.
n
00
Minute. Change with P. Accept with F.
F3
Press R to return or continue with next function (press F).
WESTERSTRAND URFABRIK AB
Box 133
SE-545 23 TÖREBODA
Tel. +46 506 48000
Fax. +46 506 48051
Internet::
e-mail:
http://www.westerstrand.se
[email protected]
Document:
Author:
Date:
Page:
WESTERSTRAND
1632en03.doc
CAn
2003-09-03
9 of 12
Relay impulse length programming – function F4
23.59
F4
S
06
F4
When the clock is in normal mode, press F to select function F4.
Pulse length. Select with P.
Number of seconds (1 to 59). Change with P.
Accept with F. Factory preset value is 6 seconds.
Press R to return or continue with next function (press F).
Setting of impulse length for slave clock output – function F5
23.59
When the clock is in normal mode, press F to select function F5.
F5
An impulse length between 0,5 and 4,0 seconds can be selected.
Press P to continue.
S
2.0
F5
Impulse length in seconds (S). Change with P. Accept with F.
Press R to return or continue with the next function (press F).
WESTERSTRAND URFABRIK AB
Box 133
SE-545 23 TÖREBODA
Tel. +46 506 48000
Fax. +46 506 48051
Internet::
e-mail:
http://www.westerstrand.se
[email protected]
Document:
Author:
Date:
Page:
WESTERSTRAND
1632en03.doc
CAn
2003-09-03
10 of 12
Setting of synchronisation source – function F6
The master clock is prepared for synchronisation via DCF/RDS (GPS optional) or minute impulse.
When the master clock is synchronised, the dot between hours and minutes is flashing each second.
23.59
F6
Sy d C
F6
When the clock is in normal mode, press F to select function F6.
Function for selection of synchronisation source. DCF (RDS/GPS) or
minute impulse (1/1 minute) can be selected. Select with P.
Sy dC = DCF (or RDS/GPS)
Sy Im = Minute impulse
Change with P. Accept with F.
Press R to return or continue with the next function (press F).
Special functions
To erase all programmed signal points for the relay output:
1) Turn OFF the master clock.
2) Press buttons R and P while the master clock is turned on.
The message ”dELE” is displayed, indicating that the erasure is completed.
Program reset
Restart of the master clock program. Already programmed signal points for the relay are intact but the real time
must be programmed with function F1 (and F2 for the slave clocks).
1) Turn OFF the master clock.
2) Press buttons R, F and P while the master clock is turned on.
The clock is restarted and ”- - - - ” is shown in the display.
WESTERSTRAND URFABRIK AB
Box 133
SE-545 23 TÖREBODA
Tel. +46 506 48000
Fax. +46 506 48051
Internet::
e-mail:
http://www.westerstrand.se
[email protected]
Document:
Author:
Date:
Page:
WESTERSTRAND
1632en03.doc
CAn
2003-09-03
11 of 12
Technical data
Supply voltage
230VAC 50Hz -5% +10%
Power consumption
10VA
Temperature range
-20°C to +50°C ambient temp.
Crystal frequency
32.768 kHz (time base)
4,0 MHz (processor)
Microprocessor
PIC16LC62A
Accuracy
±1 min/year
±4 min/year
Display
14,2 mm red LED, 4 figures and dot
Impulse memory
24 h
Impulse output
1/1-minute polar changing impulses
Impulse length 0.5-4.0 s.
Max load 100 mA
Relative humidity
Max 85% non-condensing
Protection class
IP55
Dimensions
165x120x75 mm
Relay output
Single pole, changing contact. Max. 8A/250VAC
(0°C to +40°C)
(-20°C to +50°C)
WESTERSTRAND URFABRIK AB
Box 133
SE-545 23 TÖREBODA
Tel. +46 506 48000
Fax. +46 506 48051
Internet::
e-mail:
http://www.westerstrand.se
[email protected]
Document:
Author:
Date:
Page:
WESTERSTRAND
1632en03.doc
CAn
2003-09-03
12 of 12
Programming form
No.
Signal type
(ON/OFF/pulse)
Pulse
length
Day(s)
Time
WESTERSTRAND URFABRIK AB
Box 133
SE-545 23 TÖREBODA
Tel. +46 506 48000
Fax. +46 506 48051
Internet::