GMI SRE-200 Quick Start Manual

Add to My manuals
2 Pages

advertisement

GMI SRE-200 Quick Start Manual - Workbench Assembly Guide | Manualzz
SRE-200 INSTRUCTOR STATION
TOOLS REQUIRED FOR ASSEMBLY
Cordless drill with phillips head Bit & magnetic extension,
3/8" Magnetic socket bit.
BEFORE ASSEMBLING THE WORKBENCH
Read through the assembly instructions to
familiarize yourself with the order in which the
parts are assembled. We suggest that you clear
& vacuum the area where the bench is to be
assembled. It is important that the bench is
assembled in the same sequence as instructed.
STEP 1
HARDWARE & GMI COMPONENTS
All assembly hardware is provided. Full size photos
accompany each step where hardware is needed.
Top View
Attach the modesty panel to the base cabinets and
corner pedestal. Layout as shown in the top view.
Use (2) 1/4-20 x 1/2" Bolts for each end of the
modesty panels (8 total). Hand start all bolts or
you may strip the threaded insert.
Modesty Panel
STEP 2
Fig.1
Place the two tops on the assembled base.
Adjust until it matches the view to the
right. Attach the two tops via the connector
plate using (10) #14 x 1” Lag screws.
Attach the top to the bases. Position the top
as shown in the image. (You must
remove the top drawer(s) from drawer
cabinets).
5" Spacing
Use #14 x 1" Lag Screws. (4) for each
cabinet and (9) for the leg pedestal.
1" Front
1" Left Side
STEP 3
Attach the wire covers to the back
side of the modesty panels, under
the gromet holes.
STEP 4
Double sided velcro strips are provided
for additional wire management. These
are optional. Screw them to the bottom
of the work surface as needed. Attach
with (1) #8 x 5/8" black screw in the center
of each velcro strip.
STEP 5
OPTIONAL CPU RACK
Adhesive velcro holds the bottom
lip of the cover to the modesty panel.
Use #8 x 5/8" black screws to attach
the cover to the top.
Attach the CPU rack. Instructions &
hardware are enclosed in the CPU
rack box.
Wire Cover

advertisement

Key Features

  • Adjustable height
  • Drawer cabinets
  • Corner pedestal
  • Top-mounted CPU rack
  • Modesty panel for wire management
  • Optional velcro strips
  • Durable construction

Related manuals

Frequently Answers and Questions

How many modesty panels are included with the SRE-200?
The SRE-200 comes with one modesty panel.
What type of screws are required to attach the wire covers to the modesty panel?
The manual does not specify the type of screws for the wire covers, but suggests using #8 x 5/8" black screws.
How many lag screws are needed to attach the top to the base cabinets?
4 lag screws are needed for each cabinet and 9 for the leg pedestal.
Download PDF

advertisement