Unigas IDEA NG280 Instructions For Installation, Use And Maintenance Manual 52 Pages
Unigas IDEA NG280 Instructions For Installation, Use And Maintenance Manual
Add to My manuals52 Pages
The Unigas IDEA NG280 is a microprocessor-controlled gas burner with a range of features designed for efficient combustion. It operates with natural gas, has a power output of 65-300kW, and is compatible with various boiler systems. You can adjust the gas and air flow rates for optimal performance, and the control panel provides clear feedback on operating stages. This burner is suitable for applications requiring intermittent or continuous operation and incorporates safety features for reliable performance.
advertisement
▼
Scroll to page 2
of
52
NG280 - NG350 - NG400 NGX280 - NGX350 - NGX400 LG280 - LG350 - LG400 Microprocessor-controlled gas burners MANUAL OF INSTALLATION - USE - MAINTENANCE BURNERS - BRUCIATORI - BRULERS - BRENNER - QUEMADORES - ГОРЕЛКИ M039233CA Rel. 0.1 09/2010 TABLE OF CONTENTS WARNINGS ................................................................................................................................................................ 3 PART I: INSTALLATION ........................................................................................................................................... 5 GENERAL FEATURES ................................................................................................................................................................... 5 How to interpret the burner’s “Performance curve” ......................................................................................................................... 6 BURNER FEATURES ..................................................................................................................................................................... 7 Burner model identification ............................................................................................................................................................. 7 Technical specifications .................................................................................................................................................................. 7 Low NOx burners Technical specifications ..................................................................................................................................... 9 Country and usefulness gas categories ........................................................................................................................................ 10 Performance Curves ..................................................................................................................................................................... 11 Pressure in the network - gas flow rate curves ............................................................................................................................ 13 Combustion head pressure curves vs. the gas flow rate .............................................................................................................. 15 Measuring the gas pressure in the combustion head ................................................................................................................... 15 Pressure in the combustion head vs. gas flow rate curves ........................................................................................................... 16 Overall dimensions ....................................................................................................................................................................... 18 MOUNTINGS AND CONNECTIONS ............................................................................................................................................ 20 Packing ......................................................................................................................................................................................... 20 Fitting the burner to the boiler ....................................................................................................................................................... 20 Matching the burner to the boiler .................................................................................................................................................. 20 How to modify the blast tube length .............................................................................................................................................. 21 Gas Train Reversal ....................................................................................................................................................................... 22 GAS TRAIN CONNECTIONS ....................................................................................................................................................... 24 .ELECTRICAL CONNECTIONS ................................................................................................................................................... 26 Connectors wiring diagrams ......................................................................................................................................................... 27 User interface ................................................................................................................................................................................ 29 Setting menu ................................................................................................................................................................................. 30 PHASE LIST ................................................................................................................................................................................. 31 Entering the Parameter levels ....................................................................................................................................................... 31 Info level ........................................................................................................................................................................................ 32 Service level .................................................................................................................................................................................. 34 SETTING GAS AND AIR FLOW RATE ........................................................................................................................................ 36 Startup Output ............................................................................................................................................................................... 36 Adjustments - brief description ...................................................................................................................................................... 36 Adjusting procedure ...................................................................................................................................................................... 37 Adjusting the combustion head ..................................................................................................................................................... 38 Fully modulating burners ............................................................................................................................................................... 38 Calibration of air and gas pressure switches ................................................................................................................................ 39 Calibration of air pressure switch .................................................................................................................................................. 39 Calibration of low gas pressure switch .......................................................................................................................................... 39 Adjusting the maximum gas pressure switch (when provided) ..................................................................................................... 39 PGCP Gas leakage pressure switch (witn Siemens LDU burner control/Siemens LMV Burner Management System) ............. 39 PART II: OPERATION ............................................................................................................................................. 40 OPERATION................................................................................................................................................................................. 40 PART III: MAINTENANCE ....................................................................................................................................... 42 ROUTINE MAINTENANCE ........................................................................................................................................................... 42 Removing the filter in the MULTIBLOC DUNGS MB-DLE 405..412 ............................................................................................. 42 Removing the filter in theMULTIBLOC DUNGS MB-DLE 415 - 420 ............................................................................................. 43 Adjusting the electrodes position .................................................................................................................................................. 45 Checking the detection current ..................................................................................................................................................... 45 Extraneous lightExtraneous light .................................................................................................................................................. 45 Seasonal stop ............................................................................................................................................................................... 45 Burner disposal ............................................................................................................................................................................. 45 BURNER EXPLODED VIEW ........................................................................................................................................................ 46 SPARE PARTS ............................................................................................................................................................................. 48 ELECTRICAL WIRING DIAGRAMS ............................................................................................................................................. 49 2 WARNINGS THIS MANUAL IS SUPPLIED AS AN INTEGRAL AND ESSENTIAL PART OF THE PRODUCT AND MUST BE DELIVERED TO THE USER. INFORMATION INCLUDED IN THIS SECTION ARE DEDICATED BOTH TO THE USER AND TO PERSONNEL FOLLOWING PRODUCT INSTALLATION AND MAINTENANCE. THE USER WILL FIND FURTHER INFORMATION ABOUT OPERATING AND USE RESTRICTIONS, IN THE SECOND SECTION OF THIS MANUAL. WE HIGHLY RECOMMEND TO READ IT. CAREFULLY KEEP THIS MANUAL FOR FUTURE REFERENCE. 1) GENERAL INTRODUCTION shall have qualified personnel carry out the following operations: a Remove the power supply by disconnecting the power cord from the mains. b) Disconnect the fuel supply by means of the hand-operated shut-off valve and remove the control handwheels from their spindles. The equipment must be installed in compliance with the regulations in force, following the manufacturer’s instructions, by qualified personnel. Qualified personnel means those having technical knowledge in the field of components for civil or industrial heating systems, sanitary hot water generation and particularly service centres authorised by the manufacturer. Improper installation may cause injury to people and animals, or damage to property, for which the manufacturer cannot be held liable. Remove all packaging material and inspect the equipment for integrity. In case of any doubt, do not use the unit - contact the supplier. The packaging materials (wooden crate, nails, fastening devices, plastic bags, foamed polystyrene, etc), should not be left within the reach of children, as they may prove harmful. Before any cleaning or servicing operation, disconnect the unit from the mains by turning the master switch OFF, and/or through the cutout devices that are provided. Make sure that inlet or exhaust grilles are unobstructed. In case of breakdown and/or defective unit operation, disconnect the unit. Make no attempt to repair the unit or take any direct action. Contact qualified personnel only. Units shall be repaired exclusively by a servicing centre, duly authorised by the manufacturer, with original spare parts. Failure to comply with the above instructions is likely to impair the unit’s safety. To ensure equipment efficiency and proper operation, it is essential that maintenance operations are performed by qualified personnel at regular intervals, following the manufacturer’s instructions. When a decision is made to discontinue the use of the equipment, those parts likely to constitute sources of danger shall be made harmless. In case the equipment is to be sold or transferred to another user, or in case the original user should move and leave the unit behind, make sure that these instructions accompany the equipment at all times so that they can be consulted by the new owner and/or the installer. For all the units that have been modified or have options fitted then original accessory equipment only shall be used. This unit shall be employed exclusively for the use for which it is meant. Any other use shall be considered as improper and, therefore, dangerous. The manufacturer shall not be held liable, by agreement or otherwise, for damages resulting from improper installation, use and failure to comply with the instructions supplied by the manufacturer. Special warnings Make sure that the burner has, on installation, been firmly secured to the appliance, so that the flame is generated inside the appliance firebox. Before the burner is started and, thereafter, at least once a year, have qualified personnel perform the following operations: a set the burner fuel flow rate depending on the heat input of the appliance; b set the flow rate of the combustion-supporting air to obtain a combustion efficiency level at least equal to the lower level required by the regulations in force; c check the unit operation for proper combustion, to avoid any harmful or polluting unburnt gases in excess of the limits permitted by the regulations in force; d make sure that control and safety devices are operating properly; e make sure that exhaust ducts intended to discharge the products of combustion are operating properly; f on completion of setting and adjustment operations, make sure that all mechanical locking devices of controls have been duly tightened; g make sure that a copy of the burner use and maintenance instructions is available in the boiler room. In case of a burner shut-down, reser the control box by means of the RESET pushbutton. If a second shut-down takes place, call the Technical Service, without trying to RESET further. The unit shall be operated and serviced by qualified personnel only, in compliance with the regulations in force. 3) GENERAL INSTRUCTIONS DEPENDING ON FUEL USED 3a) ELECTRICAL CONNECTION 2) SPECIAL INSTRUCTIONS FOR BURNERS The burner should be installed in a suitable room, with ventilation openings complying with the requirements of the regulations in force, and sufficient for good combustion. Only burners designed according to the regulations in force should be used. This burner should be employed exclusively for the use for which it was designed. Before connecting the burner, make sure that the unit rating is the same as delivery mains (electricity, gas oil, or other fuel). Observe caution with hot burner components. These are, usually, near to the flame and the fuel pre-heating system, they become hot during the unit operation and will remain hot for some time after the burner has stopped. When the decision is made to discontinue the use of the burner, the user For safety reasons the unit must be efficiently earthed and installed as required by current safety regulations. It is vital that all saftey requirements are met. In case of any doubt, ask for an accurate inspection of electrics by qualified personnel, since the manufacturer cannot be held liable for damages that may be caused by failure to correctly earth the equipment. Qualified personnel must inspect the system to make sure that it is adequate to take the maximum power used by the equipment shown on the equipment rating plate. In particular, make sure that the system cable cross section is adequate for the power absorbed by the unit. No adaptors, multiple outlet sockets and/or extension cables are permitted to connect the unit to the electric mains. An omnipolar switch shall be provided for connection to mains, as required by the current safety regulations. The use of any power-operated component implies observance of a few basic rules, for example: - do not touch the unit with wet or damp parts of the body and/or with bare feet; - do not pull electric cables; - do not leave the equipment exposed to weather (rain, sun, etc.) unless expressly required to do so; - do not allow children or inexperienced persons to use equipment; The unit input cable shall not be replaced by the user. In case of damage to the cable, switch off the unit and contact qualified personnel to replace. When the unit is out of use for some time the electric switch supplying all the power-driven components in the system (i.e. pumps, burner, etc.) should be switched off. 3 DIRECTIVES AND STANDARDS Gas burners European directives: - Directive 2009/142/EC - Gas Appliances; - Directive 2006/95/EC on low voltage; - Directive 2004/108/EC on electromagnetic compatibility Harmonised standards : -UNI EN 676 (Gas Burners; -CEI EN 60335-1(Household and similar electrical appliances - Safety. Part 1: General requirements; - EN 50165 (Electrical equipment of non-electric appliances for household and similar purposes. Safety requirements. 3b) FIRING WITH GAS, LIGHT OIL OR OTHER FUELS GENERAL The burner shall be installed by qualified personnel and in compliance with regulations and provisions in force; wrong installation can cause injuries to people and animals, or damage to property, for which the manufacturer cannot be held liable. Before installation, it is recommended that all the fuel supply system pipes be carefully cleaned inside, to remove foreign matter that might impair the burner operation. Before the burner is commissioned, qualified personnel should inspect the following: a the fuel supply system, for proper sealing; b the fuel flow rate, to make sure that it has been set based on the firing rate required of the burner; c the burner firing system, to make sure that it is supplied for the designed fuel type; d the fuel supply pressure, to make sure that it is included in the range shown on the rating plate; e the fuel supply system, to make sure that the system dimensions are adequate to the burner firing rate, and that the system is equipped with all the safety and control devices required by the regulations in force. When the burner is to remain idle for some time, the fuel supply tap or taps should be closed. Light oil burners European directives: - Directive 2006/95/EC on low voltage; - Directive 2004/108/EC on electromagnetic compatibility Harmonised standards : -CEI EN 60335-1(Household and similar electrical appliances - Safety. Part 1: General requirements; - EN 50165 (Electrical equipment of non-electric appliances for household and similar purposes. Safety requirements. National standards : -UNI 7824: Monobloc nebulizer burners for liquid fuels. Characteristics and test methods SPECIAL INSTRUCTIONS FOR USING GAS Have qualified personnel inspect the installation to ensure that: a the gas delivery line and train are in compliance with the regulations and provisions in force; b all gas connections are tight; c the boiler room ventilation openings are such that they ensure the air supply flow required by the current regulations, and in any case are sufficient for proper combustion. Do not use gas pipes to earth electrical equipment. Never leave the burner connected when not in use. Always shut the gas valve off. In case of prolonged absence of the user, the main gas delivery valve to the burner should be shut off. Precautions if you can smell gas a do not operate electric switches, the telephone, or any other item likely to generate sparks; b immediately open doors and windows to create an air flow to purge the room; c close the gas valves; d contact qualified personnel. Do not obstruct the ventilation openings of the room where gas appliances are installed, to avoid dangerous conditions such as the development of toxic or explosive mixtures. Heavy oil burners European directives: - Directive 2006/95/EC on low voltage; - Directive 2004/108/EC on electromagnetic compatibility Harmonised standards : -CEI EN 60335-1 Household and similar electrical appliances - SafetyPart 1: General requirements; - EN 50165 Electrical equipment of non-electric appliances for household and similar purposes. Safety requirements. National standards : -UNI 7824: Monobloc nebulizer burners for liquid fuels. Characteristics and test methods Gas - Light oil burners European directives: - Directive 2009/142/EC - Gas Appliances; - Directive 2006/95/EC on low voltage; - Directive 2004/108/EC on electromagnetic compatibility Harmonised standards : -UNI EN 676 Gas Burners -CEI EN 60335-1(Household and similar electrical appliances - Safety. Part 1: General requirements; - EN 50165 Electrical equipment of non-electric appliances for household and similar purposes. Safety requirements. National standards : -UNI 7824: Monobloc nebulizer burners for liquid fuels. Characteristics and test methods Gas - Heavy oil burners European directives: - Directive 2009/142/EC - Gas Appliances; - Directive 2006/95/EC on low voltage; - Directive 2004/108/EC on electromagnetic compatibility Harmonised standards : -UNI EN 676 (Gas Burners; -CEI EN 60335-1(Household and similar electrical appliances - Safety. Part 1: General requirements; - EN 50165 Electrical equipment of non-electric appliances for household and similar purposes. Safety requirements. National standards : -UNI 7824: Monobloc nebulizer burners for liquid fuels. Characteristics and test methods 4 PART I: INSTALLATION GENERAL FEATURES The control system is made of the Siemens LMV central unit that performs all the burner control functions and of the Siemens AZL local programming unit that interfaces the system with the user. 2 6 1 3 4 5 Fig. 1 Keys 1 Burner 2 AZL2.. 3 Air actuator 4 Fuel actuator 5 LMV2.. 6 Output modulatore (only for fully-modulating models) The burner shown is indicative. The gas coming from the supply line, passes through the valves group provided with filter and governor. This one forces the pressure in the utilisation limits. In the double-stage , progressive and fully- modulating burners, the electric actuator, that moves proportionally the air damper and the gas butterfly valve, is controlled by the LMV2 Burner Management System (BMS). This one allows the optimisation of the gas flue values, as to get an efficient combustion. The combustion head positioning determines the burner’s output. Fuel and comburent are routed into separated ways as far as the zone of flame generation (combustion chamber). The air (comburent) and fuel (gas, gas oil, heavy oil) are forced into the combustion chamber. The control panel, placed on the burner’s front side, shows each operating stage. 5 How to interpret the burner’s “Performance curve” To check if the burner is suitable for the boiler to which it must be installled, the following parameters are needed: furnace input, in kW or kcal/h (kW = kcal/h / 860); backpressure (data are available on the boiler’s ID plate or in the user’s manual). Example: Furnace input: kW 600 Backpressure: mbar 4 In the “Performance curve” diagram (Fig. 2), draw a vertical line matching the furnace input value and an horizontal line matching the backpressure value. The burner is suitable if the intersection point A is inside the performance curve. Campo di lavoro bruciatori Tipo P60 Mod. M-xx.x.IT.A.0.50 - M-.xx.x.IT.A.0.65 Contropressione in camera di combustione mbar 8 7 6 5 A 4 3 2 1 0 -1 100 200 300 400 500 600 700 800 900 Potenza kW Fig. 2 Data are referred to standard conditions: atmospheric pressure at 1013mbar, ambient temperature at 15°C. Checking the proper gas train size To check the proper gas train size, it is necessary to the available gas pressure value upstream the burner’s gas valve. Then subtract the backpressure. The result is called pgas. Draw a vertical line matching the furnace input value (600kW, in the example), quoted on the x-axis, as far as intercepitng the network pressure curve, according to the installed gas train (DN65, in the example). From the interception point, draw an horizontal line as far as matching, on the y-axis, the value of pressure necessary to get the requested furnace input. This value must be lower or equal to the pgas value, calculated before. Tipo / Type P60 M-...50 (Multibloc DUNGS MB-DLE 420 B01) M-...65 (Filtro / Filter DN65+ SIEMENS VGD40.065 +SKP1x+SKP2x) Minima pressione gas in rete / Minimum inlet gas pressure (mbar) 25 Rp 2" (50) 20 DN65 15 10 5 0 100 200 300 400 500 600 Potenza / Output (kW) Fig. 3 6 700 800 900 BURNER FEATURES Burner model identification Burners are identified by burner type and model. Burner model identification is described as follows. Type NG400 Model (1) M-. PR. S. (2) (3) (1) BURNER TYPE * A. 0. 50. EA (4) (5) (6) (7) (8) NG - Natural gas burners LG - L.P.G. burners NGX - Low NOx burners (9) (2) FUEL (3) (4) BLAST TUBE M - Natural gas L - LPG PR - Progressive S - standard MD - Fully modulating L - extended (5) DESTINATION COUNTRY * see data plate (6) BURNER VERSION A - Standard (7) EQUIPMENT (8) GAS CONNECTION (9) GAS CONNECTION 0 = 2 gas valves 1= 2 Gas valves + gas proving system) 15 = Rp1/2 20 = Rp3/4 25 = Rp1 M - modular 32 = Rp1 ¼ 40 = Rp1 ½ 50 = Rp2 EA = micro-processor controlled burner (LMV2x) EB = micro-processor controlled burner (LMV3x) Technical specifications NG280 M-.xx...x.25 BURNER TYPE Output NG280 M-.xx...x.32 NG280 M-.xx...x.40 Category Natural gas L.P.G. (see next paragraph) I3B/P 7 – 32 2,5 – 11,5 min.- max. (Stm3/h) Gas Pressure LG280 L-.xx...x.25 LG280 L-.xx...x.32 65 - 300 min.- max. kW Fuel Gas rate LG280 L-.xx...x.20 (Note2) min.- max. mbar 230V - 50Hz Power supply Total power consumption kW 0,55 Electric motor kW 0,25 IP40 Protection 1” ¼ / Rp 1 ¼ 1” ½ / Rp 1” ½ 1” / Rp 1 Valves size / Gas connection 1” / Rp1 1” / Rp1 1”1/4 / Rp 11/4 LG350 L-.xx...x.32 LG350 L-.xx...x.40 Progressive - Fully modulating Operation Operating temperature °C Storage Temperature °C -10 ÷ +50 -20 ÷ +60 Intermittent Working service* NG350 M-.xx...x.25 BURNER TYPE Output min.- max. kW LG350 L-.xx...x.25 85 - 330 Natural gas L.P.G. I3B/P I3B/P I3B/P 3 – 13 3 – 13 3 – 13 (see next paragraphsee next paragraph) Category Gas pressure NG350 M-.xx...x.40 80 - 330 Fuel Gas rate NG350 M-.xx...x.32 min.- max. (Stm3/h) 8.5 – 35 8.5 – 35 min.- max. mbar 8.5 – 35 (Note2) 230V - 50Hz Power supply Total power consumption kW Electric motor kW 0,67 0,37 IP40 Protection 1” ¼ / Rp 1 ¼ 1” ½ / Rp 1½ 1” / Rp 1 Valves size / Gas connection 1” / Rp1 Progressive - Fully modulating Operation Operating temperature °C -10 ÷ +50 Storage Temperature °C -20 ÷ +60 Intermittent Working service * 7 1”1/4 / Rp 11/4 1”1/2 / Rp 11/2 NG400 M-.xx...x.25 BURNER TYPE NG400 M-.xx...x.32 min.- max. kW Output NG400 M-.xx...x.40 115 - 420 Natural gas Fuel (see next paragraph) Category 12 - 44.5 min.- max. (Stm3/h) Gas rate min.- max. mbar Gas pressure (Note2) 230V - 50Hz Power supply Total power consumption kW 0,67/0,75 Electric motor kW 0,37/0,45 IP40 Protection 1” / Rp 1 Valves size / Gas connection 1” ¼ / Rp 1 ¼ 1” ½ / Rp 1” ½ 2” / Rp 2 Progressive - Fully modulating Operation Operating temperature °C Storage Temperature °C -10 ÷ +50 -20 ÷ +60 Intermittent Working service * LG400 L-.xx...x.25 BURNER TYPE LG400 L-.xx...x.32 min.- max. kW Output LG400 L-.xx...x.40 LG400 L-.xx...x.50 105 - 420 L.P.G. Fuel I3B/P Category Gas rate Gas pressure min.- max. (Stm3/h) 4 - 16 min.- max. mbar (Note2) 230V - 50Hz Power supply Total power consumption kW 0,67/0,75 Electric motor kW 0,37/0,45 IP40 Protection 1” / Rp 1 Valves size / Gas connection 1” ¼ / Rp 1 ¼ 1” ½ / Rp 1” ½ 2” / Rp 2 Progressive - Fully modulating Operation Operating temperature °C -10 ÷ +50 Storage Temperature °C -20 ÷ +60 Intermittent Working service * Note1: NG400 M-.xx...x.50 All gas flow rates are referred to Stm3/h (1013 mbar absolute pressure, 15 °C temperature) and are valid for G20 gas (nett calorific value Hi = 34.02 MJ/Stm3); for L.P.G. (net calorific value Hi = 93.5 MJ/Stm3) Note2: Maximum gas pressure = 360mbar (with Dungs MBDLE/MBC valves) Minimum gas pressure = see gas curves. * NOTE ON THE WORKING SERVICE: the control box automatically stops after 24h of continuous working. The control box immediately starts up, automatically. 8 Low NOx burners Technical specifications NGX280 M-.xx...x.25 BURNER TYPE NGX280 M-.xx...x.32 min.- max. kW Output 60 - 190 Natural gas Fuel (see next paragraph) Category 6,4 - 20 min.- max. (Stm /h) 3 Gas rate min.- max. mbar Gas pressure (Note2) 230V - 50Hz Power supply Total power consumption kW Electric motor kW 0,55 0,25 IP40 Protection 1”1/4 / Rp 11/4 1” / Rp1 Valves size / Gas connection 1”1/2 / Rp 11/2 Progressive - Fully modulating Operation Class 3 - EN676/2008 NOx emissions Operating temperature °C Storage Temperature °C -10 ÷ +50 -20 ÷ +60 Intermitent Working service * NGX350 M-.xx...x.25 BURNER TYPE NGX350 M-.xx...x.32 min.- max. kW Output NGX350 M-.xx...x.40 65 - 260 Natural gas Fuel (see next paragraph) Category Gas rate min.- max. min.max.(Stm3/h) Gas pressure min.- max. mbar 7 - 27.5 (Note2) 230V - 50Hz Power supply Total power consumption kW Electric motor kW 0,67 0,37 IP40 Protection 1”1/4 / Rp 11/4 1” / Rp1 Valves size / Gas connection 1”1/2 / Rp 11/2 Progressive - Fully modulating Operation Class 3 - EN676/2008 NOx emissions Operating temperature °C -10 ÷ +50 Storage Temperature °C -20 ÷ +60 Intermitent Working service * Note1: NGX280 M-.xx...x.40 All gas flow rates are referred to Stm3/h (1013 mbar absolute pressure, 15 °C temperature) and are valid for G20 gas (net calorific value Hi = 34.02 MJ/Stm3); for L.P.G. (net calorific value Hi = 93.5 MJ/Stm3) Note2: Maximum gas pressure = 360mbar (with Dungs MBDLE/MBC valves) Minimum gas pressure = see gas curves. * NOTE ON THE WORKING SERVICE: the control box automatically stops after 24h of continuous working. The control box immediately starts up, automatically. 9 NGX400 M-.xx...x.25 BURNER TYPE NGX400 M-.xx...x.32 min.- max. kW Output NGX400 M-.xx...x.40 NGX400 M-.xx...x.50 90 - 350 Natural gas Fuel (see next paragraph) Category Gas rate Gas pressure min.- max. (Stm3/h) 9.5 - 37 min.- max. mbar (Note2) 230V - 50Hz Power supply Total power consumption kW 0,67/0,75 Electric motor kW 0,37/0,45 IP40 Protection 1” ¼ / Rp 1 ¼ 1” / Rp 1 Valves size / Gas connection 2” / Rp 2 Class 3 - EN676/2008 NOx emissions Operating temperature °C Storage Temperature °C -10 ÷ +50 -20 ÷ +60 Intermittent Working serivce * Note1: 1” ½ / Rp 1” ½ Progressive - Fully modulating Operation All gas flow rates are referred to Stm3/h (1013 mbar absolute pressure, 15 °C temperature) and are valid for G20 gas (net calorific value Hi = 34.02 MJ/Stm3); for L.P.G. (net calorific value Hi = 93.5 MJ/Stm3) Note2: Maximum gas pressure = 360mbar (with Dungs MBDLE/MBC valves) Minimum gas pressure = see gas curves. * NOTE ON THE WORKING SERVICE: the control box automatically stops after 24h of continuous working. The control box immediately starts up, automatically. Country and usefulness gas categories GAS CATEGORY COUNTRY I2H AT ES G SE FI IE HU IS N CZ DK GB IT I2E LU PL - - - - - - - - - - - - - - - - - - - - - - - I2E( R ) B BE - - - - - - - - - - - - - - - - - - - - - - - - I2L NL - - - - - - - - - - - - - - - - - - - - - - - - I2ELL DE - - - - - - - - - - - - - - - - - - - - - - - - I2Er FR - - - - - - - - - - - - - - - - - - - - - - - - 10 PT CY EE LV SI MT SK BG LT R TR CH Performance Curves Gas burners BACK PRESSURE IN COMBUSTION CHAMBER mbar BACK PRESSURE IN COMBUSTION CHAMBER mbar NG280 7 6 6 5 4 4 3 2 2 1 0 0 50 100 150 200 250 300 350 50 100 150 200 250 300 350 400 kW kW NG400 9 8 7 6 5 4 3 2 1 0 100 150 200 250 300 350 400 450 kW BACK PRESSURE IN CCOMBUSTION CHAMBER mbar L.P.G. Burners BACK PRESSURE IN CCOMBUSTION CHAMBER mbar NG350 LG280 LG350 7 6 6 5 4 4 3 2 2 1 0 0 50 100 150 200 250 300 50 350 LG400 8 6 4 2 0 100 150 200 250 300 350 400 150 200 250 300 350 kW kW 50 100 450 kW 11 Low NOx burners BACK PRESSURE IN CCOMBUSTION CHAMBER mbar BACK PRESSURE IN CCOMBUSTION CHAMBER mbar NGX280 6 5 4 3 2 1 0 40 80 120 160 200 kW NGX350 NGX400 7 9 8 7 6 5 4 3 2 1 0 6 5 4 3 2 1 0 50 100 150 200 250 50 300 kW 100 150 200 250 300 350 400 kW NOTE: The performance curve is a diagram that represents the burner performance in the type approval phase or in the laboratory tests, but does not represent the regulation range of the machine. On this diagram the maximum output point is usually reached by adjsuting the combustion head to its “MAX” position (see paragraph “Adjusting the combustion head”); the minimum output point is reached setting the combustion head to its “MIN” position. During the first ignition, the combustion head is set in order to find a compromise between the burner output and the generator specifications, that is why the minimum output may be different from the Performance curve minimum. 12 Pressure in the network - gas flow rate curves Gas burners NG280 M-.AB... NG350 M-.PR/MD... 100 100 Rp ½ " (15) GAS PRESSURE mbar Rp ½" (15) 80 80 60 60 Rp ¾" (20) 40 40 Rp ¾ " (20) Rp 1" (25) Rp 1" (25) 20 20 Rp 1"¼ (32) Rp 1"¼ (32) Rp 1"½ (40) 0 5 10 15 20 25 30 35 0 40 5 10 15 20 25 30 35 40 45 Gas rate Stm3/h 3 Gas rate Stm /h NG400 M-.PR/MD...32-40-50 18 GAS PRESSURE mbar 16 Rp 1"¼ (32) 14 12 Rp 1"½ (40) 10 Rp 2" (50) 8 6 4 2 0 10 15 20 25 30 35 40 45 50 55 Gas rate Stm3/h L.P.G. Burners LG280 L-.AB... LG350 L-.PR.... 50 60 GAS PRESSURE mbar Rp ½" (15) Rp ½" (15) 50 40 40 30 Rp ¾1" (20) Rp ¾" (20) 30 Rp 1" (25) Rp 1" (25) 20 20 Rp 1"¼ (32) 10 Rp 1"¼ (32) 10 0 0 2 4 6 8 10 12 2 14 3 4 6 8 10 12 14 16 Gas rate Stm3/h Gas rate Stm /h LG400 L-.PR/MD.... GAS PRESSURE mbar 70 Rp ½" (15) 60 50 Rp ¾" (20) 40 Rp 1" (25) 30 Rp 1"¼ (32) 20 Rp 1"½ (40) 10 0 2 4 6 8 10 12 14 16 18 20 Gas rate Stm3/h Caution: the gas rate value is quoted on the x-axis, the related network pressure is quoted on the y-axis (pressure value in the combustion chamber is not included). To know the minimum pressure at the gas train inlet, necessary to get the requested gas rate, add the pressure value in the combustion chamber to the value read on the y-axis. 13 Low NOx burners NGX280 NGX350 80 30 R p ½ " (1 5 ) 70 R p ¾" ( 2 0 ) GAS PRESSURE mbar 25 60 50 20 R p 1" ( 2 5 ) 40 15 10 R p 1"¼ ( 3 2 ) 30 R p 1"½ ( 4 0 ) 20 R p ¾ " (2 0 ) R p 1 " (2 5 ) R p 1 "¼ (3 2 ) R p 1 "½ (4 0 ) 10 5 0 5 0 4 6 8 10 12 14 16 18 20 22 24 10 15 20 25 30 35 Gas rate Stm3/h 26 Gas rate Stm3/h NGX400 M-...15-20-25 NGX400 M-...32-40-50 16 R p 1"¼ (32) Rp ½" (15) 100 GAS PRESSURE mbar 14 R p 1"½ (40) 12 80 R p 2" (50) 10 Rp ¾" (20) 60 8 6 40 4 Rp 1" (25) 20 2 0 0 5 10 15 20 25 30 35 40 45 50 5 Gas rate Stm3/h 10 15 20 25 30 35 40 45 50 Gas rate Stm3/h Caution: the gas rate value is quoted on the x-axis, the related network pressure is quoted on the y-axis (pressure value in the combustion chamber is not included). To know the minimum pressure at the gas train inlet, necessary to get the requested gas rate, add the pressure value in the combustion chamber to the value read on the y-axis. 14 Combustion head pressure curves vs. the gas flow rate Curves are referred to pressure= 0mbar in the combustion head! The curves referred to the gas pressure in the combustion head, depending on the gas flow rate, are referred to the burner in the combustion stage (percentage of residual O2 in the flues as shown in the “Recommended combustion values” table and CO in the standard limits). During this stage, the combustion head, the gas butterfly valve and the servocontrol are at the maximum opening. Refer to Fig. 4, showing the correct way to measure the gas pressure, considering the values of pressure in combustion chamber, surveyed by means of the pressure gauge or taken from the boiler’s Technical specifications. 1 2 4 3 Fig. 4 Key 1 Generator 2 Pressure outlet on the combustion chamber 3 Gas pressure outlet on the butterfly valve 4 Differential pressure gauge Measuring the gas pressure in the combustion head In order to measure the pressure in the combustion head, insert the pressure gauge probes: one into the generator’s pressure outlet (Fig. 4-2) to get the pressure in the combustion chamber and the other one into the butterfly valve’s pressure outlet of the burner (Fig. 4-3). On the basis of the measured differential pressure, it is possible to get the maximum flow rate: in the pressure - rate curves (showed on the next paragraph), it is easy to get the burner output in kW or Stm3/h (quoted on the x axis) from the pressure measured in the combustion head (quoted on the y axis). NOTE: THE PRESSURE-RATE CURVES ARE APPROXIMATE; FOR A PROPER SETTING OF THE GAS RATE, PLEASE REFER TO THE GAS METER READING. To measure the pressure in the combustion chamber, as far as the IDEA series, a pressure plug is provided upstream the burner’s blast tube. Pressure plug in combustion chamber Fan air pressure plug Fig. 5 15 Pressure in the combustion head vs. gas flow rate curves Natural gas burners NG280 16 Gas backpressure in combustion head 14 12 10 8 6 4 2 0 6 10 14 18 22 26 30 34 Gas rate Stm3/h NG400 NG350 9 12 Gas backpressure in combustion head 8 10 7 6 8 5 6 4 3 4 2 2 1 0 0 5 10 15 20 25 30 35 40 10 15 20 25 30 35 Gas rate Stm /h 40 45 Gas rate Stm3/h 3 L.P.G. Burners LG280 18 Gas backpressure in combustion head 16 14 12 10 8 6 4 2 0 2 3 4 5 6 7 8 9 10 11 12 13 Gas rate Stm3/h LG400 LG350 Gas backpressure in combustion head 25 20 20 15 15 10 10 5 5 0 0 2 4 6 8 10 12 14 4 Gas rate Stm /h 3 16 6 8 10 12 14 16 18 Gas rate Stm3/h Low NOx burners NGX280 Gas backpressure in combustion head 14 12 10 8 6 4 2 0 4 6 8 10 12 14 16 18 20 Gas rate Stm3/h Gas backpressure in combustion head NGX350 NGX400 18 10 16 9 14 8 12 7 6 10 5 8 4 6 3 4 2 2 1 0 0 6 8 10 12 14 16 18 20 22 24 26 28 30 Gas rate Stm3/h 17 5 10 15 20 25 30 35 40 Gas rate Stm3/h Overall dimensions (mm) z Standard burners Boiler recommended drilling template and burner flange 18 NG280 M-..PR..Ex NG280 M-..PR..Ex NG280 M-..PR..Ex NG280 M-..PR..Ex NG280 M-..MD..Ex NG280 M-..MD..Ex NG280 M-..MD..Ex NG280 M-..MD..Ex DN 0.25 (1") 0.32 (1"1/4) 0.40 (1"1/2) 0.50 (2") 0.25 (1") 0.32 (1"1/4) 0.40 (1"1/2) 0.50 (2") DN A(S*) 733 733 733 733 733 733 733 733 A(L*) 878 878 878 878 878 878 878 878 B(S*) 163 163 163 163 163 163 163 163 B(L*) 308 308 308 308 308 308 308 308 A(S*) A(L*) B(S*) B(L*) C D C D ±5mm E ±5mm 570 596 200 570 596 200 570 726 330 570 726 330 570 668 200 570 668 200 570 798 330 570 798 330 ±5mmE 0.25 (1") 748 878 178 308 570 596 NG350 M-..PR..Ex 0.32 (1"1/4) 748 878 178 308 570 596 NG350 M-..PR..Ex 0.40 (1"1/2) 748 878 178 308 570 726 NG350 M-..PR..Ex 0.50 (2") 748 878 178 308 570 726 NG350 M-..PR..Ex 0.25 (1") 748 878 178 308 570 668 NG350 M-..MD..Ex 0.32 (1"1/4) 748 878 178 308 570 668 NG350 M-..MD..Ex 0.40 (1"1/2) 748 878 178 308 570 798 NG350 M-..MD..Ex 0.50 (2") 748 878 178 308 570 798 NG350 M-..MD..Ex When PGMAX (maximum pressure switch) is supplied, add 60mm F 396 396 396 396 468 468 468 468 G 113 113 113 113 113 113 113 113 H 164 164 164 164 164 164 164 164 Y 108 108 108 108 108 108 108 108 K1 215 215 215 215 215 215 215 215 K2 223 223 223 223 223 223 223 223 L 348 348 348 348 348 348 348 348 M M10 M10 M10 M10 M10 M10 M10 M10 N 219 219 219 219 219 219 219 219 Omin Omax P Q R S T W X 131 179 155 459 366 93 128 508 491 131 179 155 459 366 93 128 508 491 131 179 155 459 366 93 128 517 491 131 179 155 459 366 93 128 567 491 131 179 155 459 366 93 128 508 491 131 179 155 459 366 93 128 508 491 131 179 155 459 366 93 128 517 491 131 179 155 459 366 93 128 567 491 ±5mm F G H Y K1 K2 L M N OminOmax P Q R S T W X 200 396125164144215223348M10219 131 179 1554593669389508491 200 396125164144215223348M10219 131 179 1554593669389508491 330 396125164144215223348M10219 131 179 1554593669389517491 330 396125164144215223348M10219 131 179 1554593669389567491 200 468125164144215223348M10219 131 179 1554593669389508491 200 468125164144215223348M10219 131 179 1554593669389508491 330 468125164144215223348M10219 131 179 1554593669389517491 330 468125164144215223348M10219 131 179 1554593669389567491 to "D" and "E" NG400 M-..PR..Ex NG400 M-..PR..Ex NG400 M-..PR..Ex NG400 M-..PR..Ex NG400 M-..MD..Ex NG400 M-..MD..Ex NG400 M-..MD..Ex NG400 M-..MD..Ex NGX280 M-..PR..Ex NGX280 M-..PR..Ex NGX280 M-..PR..Ex NGX280 M-..PR..Ex NGX280 M-..MD..Ex NGX280 M-..MD..Ex NGX280 M-..MD..Ex NGX280 M-..MD..Ex DN A(S*) A(L*) B(S*) B(L*) C D 0.25 (1") 768 898 198 328 570 0.32 (1"1/4) 768 898 198 328 570 0.40 (1"1/2) 768 898 198 328 570 0.50 (2") 768 898 198 328 570 0.25 (1") 768 898 198 328 570 0.32 (1"1/4) 768 898 198 328 570 0.40 (1"1/2) 768 898 198 328 570 0.50 (2") 768 898 198 328 570 DN 0.25 (1") 0.32 (1"1/4) 0.40 (1"1/2) 0.50 (2") 0.25 (1") 0.32 (1"1/4) 0.40 (1"1/2) 0.50 (2") A(S*) 733 733 733 733 733 733 733 733 A(L*) 878 878 878 878 878 878 878 878 B(S*) 163 163 163 163 163 163 163 163 ±5mmE 596 596 726 726 668 668 798 798 B(L*) 308 308 308 308 308 308 308 308 ±5mm F G H Y K1 K2 L M N OminOmax P Q R S T W X 200 396144164144215223348M10219 131 179 1554593669389508496 200 396144164144215223348M10219 131 179 1554593669389508496 330 396144164144215223348M10219 131 179 1554593669389517496 330 396144164144215223348M10219 131 179 1554593669389567496 200 468144164144215223348M10219 131 179 1554593669389508496 200 468144164144215223348M10219 131 179 1554593669389508496 330 468144164144215223348M10219 131 179 1554593669389517496 330 468144164144215223348M10219 131 179 1554593669389567496 C D ±5mm E ±5mm 570 596 200 570 596 200 570 726 330 570 726 330 570 668 200 570 668 200 570 798 330 570 798 330 F 396 396 396 396 468 468 468 468 G 117 117 117 117 117 117 117 117 H 137 137 137 137 137 137 137 137 Y 108 108 108 108 108 108 108 108 K1 215 215 215 215 215 215 215 215 K2 223 223 223 223 223 223 223 223 L 348 348 348 348 348 348 348 348 M M10 M10 M10 M10 M10 M10 M10 M10 N 219 219 219 219 219 219 219 219 Omin Omax P Q R S T W X 131 179 155 459 366 93 128 508 491 131 179 155 459 366 93 128 508 491 131 179 155 459 366 93 128 517 491 131 179 155 459 366 93 128 567 491 131 179 155 459 366 93 128 508 491 131 179 155 459 366 93 128 508 491 131 179 155 459 366 93 128 517 491 131 179 155 459 366 93 128 567 491 19 NGX350 M-..PR..Ex NGX350 M-..PR..Ex NGX350 M-..PR..Ex NGX350 M-..PR..Ex NGX350 M-..MD..Ex NGX350 M-..MD..Ex NGX350 M-..MD..Ex NGX350 M-..MD..Ex DN A(S*) A(L*) B(S*) B(L*) C D 0.25 (1") 748 878 178 308 570 0.32 (1"1/4) 748 878 178 308 570 0.40 (1"1/2) 748 878 178 308 570 0.50 (2") 748 878 178 308 570 0.25 (1") 748 878 178 308 570 0.32 (1"1/4) 748 878 178 308 570 0.40 (1"1/2) 748 878 178 308 570 0.50 (2") 748 878 178 308 570 ±5mmE 596 596 726 726 668 668 798 798 ±5mm F G H Y K1 K2 L M N OminOmax P Q R S T W X 200 396131164144215223348M10219 131 179 1554593669389508491 200 396131164144215223348M10219 131 179 1554593669389508491 330 396131164144215223348M10219 131 179 1554593669389517491 330 396131164144215223348M10219 131 179 1554593669389567491 200 468131164144215223348M10219 131 179 1554593669389508491 200 468131164144215223348M10219 131 179 1554593669389508491 330 468131164144215223348M10219 131 179 1554593669389517491 330 468131164144215223348M10219 131 179 1554593669389567491 NGX400 M-..PR..Ex NGX400 M-..PR..Ex NGX400 M-..PR..Ex NGX400 M-..PR..Ex NGX400 M-..MD..Ex NGX400 M-..MD..Ex NGX400 M-..MD..Ex NGX400 M-..MD..Ex DN A(S*) A(L*) B(S*) B(L*) C D 0.25 (1") 768 898 198 328 570 0.32 (1"1/4) 768 898 198 328 570 0.40 (1"1/2) 768 898 198 328 570 0.50 (2") 768 898 198 328 570 0.25 (1") 768 898 198 328 570 0.32 (1"1/4) 768 898 198 328 570 0.40 (1"1/2) 768 898 198 328 570 0.50 (2") 768 898 198 328 570 ±5mmE 596 596 726 726 668 668 798 798 ±5mm F G H Y J K1 K2 L M N OminOmax P Q R S T W X 200 396156176156 - 215223348M10219 131 179 1554593669389508496 200 396156176156 - 215223348M10219 131 179 1554593669389508496 330 396156176156 - 215223348M10219 131 179 1554593669389517496 330 396156176156 - 215223348M10219 131 179 1554593669389567496 200 468156176156 - 215223348M10219 131 179 1554593669389508496 200 468156176156 - 215223348M10219 131 179 1554593669389508496 330 468156176156 - 215223348M10219 131 179 1554593669389517496 330 468156176156 - 215223348M10219 131 179 1554593669389567496 * S = standard blast tube L = long blast tube When PGMAX (maximum pressure switch) is supplied, add 60mm to "D" and "E" MOUNTINGS AND CONNECTIONS Packing The burners are despatched in cardboard packages whose dimensions are: 795mm x 490mm x 550mm (L x P x H) Packing cases of this type are affected by humidity; the maximum number of cases to be stacked is indicated outside the packing. The following are placed in each packing case. Burner with gas train; gasket to be inserted between the burner and the boiler; envelope containing tis manual When disposing of the burner packing and if the packing is scrapped follow the procedures laid down in the current legislation regarding the disposal of materials. Fitting the burner to the boiler To perform the installation, proceed as follows: 1 place the 4 stud bolts on the hole of the boiler’s door, according to the burner’s drilling plate described on paragraph “Overall dimensions”; 2 place the gasket on the burner’s flange; 3 install the burner into the boiler; 4 fix the burner to the stud bolts, by means of the fixing nuts, according to Fig. 6. 5 After fitting the burner to the boiler, ensure that the gap between the blast tube and the refractory lining is sealed with appropriate insulating material (ceramic fibre cord or refractory cement). Key 1 Burner 2 Fixing nut 3 Washer 4 Sealing gasket 5 Stud bolt 7 Blast tube Fig. 6 Matching the burner to the boiler The burners described in this manual have been tested with combustion chambers that comply with EN676 regulation and whose dimensions are described in the diagram . In case the burner must be coupled with boilers with a combustion chamber smaller in diameter or shorter than those described in the diagram, please contact the supplier, to verify that a correct matching is possible, with respect of the application involved. To correctly match the burner to the boiler verify the necessary input and the pressure in combustion chamber are included in the burner performance curve; otherwise the choice of the burner must be revised consulting the burner manufacturer. To choose the blast tube lenght follow the instructions of the boiler manufacturer. In absence of these consider the following: Cast-iron boilers, three pass flue boilers (with the first pass in the rear part): the blast tube must protrude no more than 100 mm into the combustion chamber. Pressurised boilers with flame reversal: in this case the blast tube must penetrate at least 50 - 100 mm into combustion chamber in respect to the tube bundle plate. The length of the blast tubes does not always allow this requirement to be met, and thus it may be necessary to use a suitably-sized spacer to move the burner backwards or to design a blast tube tha suites the utilisation (please, contact the manifacturer). Key a) Heat output in kW b) Length of the flame tube in meters c) Flame tube firing intensity in MW/m3 d) Combustion chamber diameter (m) Fig. 7 - Firing intensity, diameter and lenght of the test flame tube as a function of the heat input in kW. Fig. 7 20 How to modify the blast tube length (NG/LG350-NG/LG400) To modify blast tube length please read the following instructions. 1 Remove combustion head (See “Removing the combustion head” - Part III of this user’s guide). 2 Remove the flanged piece T by removing the 4 socket head screws VTF (Fig. 8). 3 Remove the 4 screws which hold the blast tube to the flanged piece (Fig. 9). 4 Extract the blast tube from the flanged piece and assemble it in the other way round as shown in pictures Fig. 10 and Fig. 11. Now fasten the two pieces using the same screws. 5 Assemble the whole piece to the burner by caring attention to the indication in picture Fig. 13. T VTF Fig. 9 Fig. 8 Fig. 10 - Short blast tube Fig. 11 - Long blast tube Fig. 12 Fig. 13 If you modify the blast tube length you have to modify also the combustion head length by reading the following instructions. 1 Remove the screws V1 and V2 as shown in Fig. 14. 2 Lower the terminal part of the combustion head, by moving it with a slight circular movement, until the holes will match (Fig. 15) and tight the screw shown in Fig. 16. 3 Adjust cables length by pulling them very slightly paying particular attention not to disconnect the ionisation cable to the electrode. 4 Fix the combustion head again (See “Removing the combustion head”). 21 V2 V1 Fig. 14 Fig. 16 Fig. 15 Gas Train Reversal The gas train can be fit either on the left and on the right. Follow these instruction.. 1 Remove the plastic hook G to release the rod T (Fig. 17) . 2 Take the screws V1, V2, V3, V4, VT1 and VT2 off (Fig. 17). 3 Take the ignition cable CA off of the transformer . 4 Disconnect the connector CR from the printed cirduit (Fig. 18). 5 Take off the flange and the combustion head together (Fig. 20). 6 Take the gas pipe TR off and put it in the new position fixing the screws VT1 and VT2 (Fig. 19). LOCKED UNLOCKED V2 V1 S1 VT1 G G TR T V4 S2 VT2 V3 Fig. 17 CR VT1 CA TR VT2 Fig. 18 Fig. 19 22 G F V Fig. 21 Fig. 20 7 Unscrew the V, rotate the head of 180 ° along its axis as shown in Fig. 20), until the hole F is found. Fit the screw again (Fig. 20 Fig. 21). 8 Insert again the flange and the combustion head together 9 Rotate the disc D following the instructions below. 10 Take off the screw VF. 11 Rotate the disc D for 180 ° and then fit the screw VF (Fig. 22). D D TR VF Fig. 22: Standard position Fig. 23: New position 12 Reconnect CR and CA. 13 Retighten the screws V1, V2, V3, V4, VT1 e VT2. 14 Place again the rod T into its own position and fasten it by the plastic hook G. 23 GAS TRAIN CONNECTIONS This paragraph shows the gas train components which are included in the delivery and those which must be fitted by the customer. The diagram complies with regulations in force ATTENTION: BEFORE EXECUTING THE CONNECTIONS TO THE GAS PIPE NETWORK, BE SURE THAT THE MANUAL CUTOFF VALVES ARE CLOSED. READ CAREFULLY THE “WARNINGS” CHAPTER AT THE BEGINNING OF THIS MANUAL. Gas train with valves group MB-DLE (2 valves + gas filter + pressure governor) + VPS504 gas proving system MANUFACTURER 9 4 4 INSTALLER 5 1 2 7 8 16 Key 1 Burner 2 Butterfly valve 4 High gas pressure switch (option*) 5 Low gas pressure switch 7 Bellows unit 8 Manual cutoff valve 9 Dungs MB-DLE valves group 16 Gas leakage pressure switch * Note: the maximum gas pressure switch can be mounted either upstream or downstream the gas valve but upstream the butterfly gas valve (see item no.4 in the scheme above). To mount the gas train, proceed as follows: 1) in case of threaded joints: use proper seals according to the gas used; 2) fasten all the items by means of screws, according to the next diagrams, observing the mounting direction for each item. NOTE: the bellow joint, the manual cock and the gaskets are not part of the standard supply. The procedures of installation fo the gas valves are showed in the next paragraph. ATTENTION: once the gas train is mounted according to the diagram, the gas proving test mus be performed, according to the procedure set by the laws in force. ATTENTION: it is recommended to mount filter and gas valves to avoid that extraneous material drops inside the valves, during maintenance and cleaning operation of the filters (both the filters outside the valves group and the ones built-in the gas valves). 24 MULTIBLOC DUNGS MB-DLE 405..412 Mounting 1. Mount flange onto tube lines: use appropriate sealing agent (see Fig. 30); 2. insert MB-DLE: note position of O rings (see Fig. 30); 3. tighten screws A, B, C and D (Fig. 28 - Fig. 29), accordind to the mounting positions (Fig. 31); 4. after installation, perform leakage and functional test; 5. disassembly in reverse order. MOUNTING POSITIONS C A D B Fig. 24 Fig. 25 Fig. 26 Fig. 27 MULTIBLOC DUNGS MB-DLE 415..420 Mounting 1. Loosen screws A and B do not unscrew (Fig. 28 - Fig. 29). 2. unscrew screws C and D (Fig. 28 - Fig. 29). 3. Remove MultiBloc between the threaded flanges (Fig. 29). 4. After mounting, perform leakage and functional tests. MOUNTING POSITIONS C A D B Fig. 28 A C B D Fig. 29 Fig. 30 Once the train is installed, connect the gas valves group plug. 25 Fig. 31 .ELECTRICAL CONNECTIONS RESPECT THE BASIC SAFETY RULES. MAKE SURE OF THE CONNECTION TO THE EARTHING SYSTEM. DO NOT REVERSE THE PHASE AND NEUTRAL CONNECTIONS. FIT A DIFFERENTIAL THERMAL MAGNET SWITCH ADEQUATE FOR CONNECTION TO THE MAINS. ATTENTION: before executing the electrical connections, pay attention to turn the plant’s switch to OFF and be sure that the burner’s main switch is in 0 position (OFF) too. Read carefully the chapter “WARNINGS”, and the “Electrical connections” section. WARNING: if the cable that connects the thermostats and the control box should be longer than 3 meters, insert a sectioning relay following the attached electrical wiring diagram. To execute the electrical connections, proceed as follows: 1 find the pulg or the plugs, according to the model, that comes out from the burnrer: 7 pins plug for the power supply (for all models); 4 pins plug; 3-pins plug (only for NG/NGX400); 2 execute the electrical connections to the plugs, according to hte burner model (see next paragraph); 3 once all the connections are accomplished, check the fan motor direction (sse next paragraphs); 4 now the burner is ready to start up. The burner is fitted with a bridge between terminals T6 and T8 on the 4-poles plug-TAB (external side link, male connector); if the TAB high/low flame thermostat must be connected, remove the bridge between terminals, before connecting the thermostat. IMPORTANT: before operating the burner, be sure all connectors are linked as shown in the diagrams. Connectors identification Burner power supply connector (Fig. 35 - Fig. 37 - Fig. 39) Probe connection connector (fully modulating burners, Fig. 41) Fig. 32 HIGH/LOW flame connector(Fig. 37) Fig. 33 Fan motor connector (NG/NGX400 only) (Fig. 36 - Fig. 38 - Fig. 40) Fig. 34 26 Connectors wiring diagrams Fig. 35 - 7-pins connector Fig. 36 - Electric motor’s 3-pins connector NG/LG/NGX400 Progressive burners’ connectors: Fig. 38Electric motor’s 3-pin connector for NG/LG/NGX400 Fig. 37 - 7-pin and 4-pin connectors Key C1 LBF BURNER IN LOW FLAME SIGNALLING LAMP LOW FLAME TIME METER MV FAN MOTOR C2 HIGH FLAME TIME METER ST THERMOSTATS O PRESSURE SWITCHES SERIE FU1 FAN MOTOR LINE FUSE TAB HIGH LOW FLAME THERMOSTAT/PRESSURE SWITCH FU3 LINE FUSE TS SAFETY THERMOSTAT/PRESSURE SWITCH IL BURNER LINE SWITCH CONN-MOTORE FAN MOTOR CONNECTOR IM FAN MOTOR LINE SWITCH CONN-LINEA BURNER POWER SUPPLY CONNNECTOR KM1 FAN MOTOR CONTACTOR CONN-TAB HIGH-LOW FLAME CONNECTOR LAF BURNER IN HIGH FLAME INDICATOR LIGHT LB INDICATOR LIGHT FOR BURNER LOCK-OUT ($) 27 IF "TAB" USED REMOVE THE BRIDGE BETWEEN TERMINALS T6-T8 Fully-modulating burners’ connectors: Fig. 39 - 7-pin connector Fig. 41 - Probes connectiion Fig. 40 - Electric motor’s 3-pin connector for NG/LG/NGXG400 Key C1 LOW FLAME TIME METER FU1 LINE FUSE FOR FAN MOTOR FU3 LINE FUSE FU4 AUXILIARY FUSE IL BURNER LINE SWITCH IM FAN MOTOR LINE SWITCH KM1 FAN MOTOR REMOTE CONTACTOR LANDIS RWF40 MODULATION REGULATOR LB BURNER LOCKOUT SIGNALLING LAMP LBF BURNER IN LOW FLAME SIGNALLING LAMP MV FAN MOTOR SD-0÷10V VOLTAGE SIGNAL SD-0/4÷20mA CURENT SIGNAL SD-PRESS PRESSURE PROBE SMA MAN/AUTO SELECTOR SMF OPERATION SELECTOR MIN-0-MAX ST PRESSURE SWITCHES OR THERMOSTATS SERIE TS SAFETY THERMOSTAT/PRESSURE SWITCH 28 User interface Bild 1/0707 The AZL2x.. display is shown below: The keys functions are the following: P V h min s VSD F % nfo ESC A Key F Used to adjust the “fuel” actuator position (Fuel): : While pressing the F key, the “fuel” actuator position can be changed by means of the + and - keys. Key A Used to adjust the “air” actuator position (Air): While pressing the A key, the “air” actuator position can be changed by means of the + and - keys. Key F + A While pressing the two keys contemporarly, the code message will appear: by entering the proper password it is possible to access the Service mode. Info and Enter keys Used for Info and Service menues Used as Enter key in the setting modes Used as Reset key in the burner operation mode Used to enter a lower level menu -Key Used to decrease a a value Used to enter Info and Serivce during the curve adjustments +Key + Used to increase a a value Used to enter Info and Serivce during the curve adjustments Keys (+ & - )= ESC By pressing + and - at the same time, the ESCAPE function is perfomed: to erase a entered value to enter a lower level menu 29 The display will show these data: Lock+unlock codes Flame Open valves Ignition transformers energised Fan motor energised Oil pre-heater energised Plant heat request Parametere setting mode P Info mode Service mode V Closing actuator h min s % Opening actuator Unit measure The display will show these data: Setting menu The setting menu is divided into different blocks: Bloc. Descrizione Description Password 100 Informazioni generali General 200 Controllo bruciatore Burner control OEM / Service / Info OEM / Service 400 Curve rapporto Ratio curves OEM / Service 500 Controllo rapporto Ratio control OEM / Service 600 Servocomandi Actuators 700 Storico errori Error history OEM / Service / Info 900 Dati di processo Process data OEM / Service / Info The accesses to the various blocks are allowed by passwords. Passwords are divided into three levels: User level (info): no password needed Service level (Service) Manifacturer level (OEM) 30 OEM / Service PHASES LIST During operation, the following program phases are shown. The meaning for each phase is quoted in the table below Phase Funzione Function Ph00 Fase blocco Lockout phase Ph01 Fase di sicurezza Safety phase Ph10 t10 = tempo raggiungimento posizione riposo t10 = home run Ph12 Pausa Standby (stationary) Ph22 t22 = tempo di salita ventilatore (motore ventilatore = ON, t22 = fan ramp up time (fan motor = ON, valvola intercettazione di sicurezza = ON) safety shutoff valve = ON) Ph24 Verso posizione preventilazione Traveling to the prepurge position Ph30 t1 = tempo preventilazione t1 = prepurge time Ph36 Verso posizione accensione Traveling to the ignition position Ph38 t3 = tempo preaccensione t3 = preignition time Ph40 TSA1 = primo tempo sicurezza (trasformatore accensione ON) TSA1= 1st safety time (ignition transformer ON) Ph42 TSA1 = primo tempo sicurezza (trasformatore accensione OFF) TSA1 = 1st safety time (ignition transformer OFF) t42 = preignition time OFF Ph44 t44 = intervallo 1 t44 = interval 1 Ph50 TSA2 = secondo tempo sicurezza TSA2 = 2nd safety time Ph52 t52 = intervallo2 t52 = interval 2 Ph60 Funzionamento 1 (stazionario) Operation 1 (stationary) Ph62 t62 = massimo tempo bassa fiamma (funzionamento 2, in t62 = max. time low-fire (operation 2, prepapreparazione per spegnimento, verso bassa fiamma) ring for shutdown, traveling to low-fire) Ph70 t13 = tempo postcombustione Ph72 Verso posizione postcombustione Traveling to the postpurge position Ph74 t8 = tempo postventilazione t8 = postpurge time Ph80 t80 = tempo evacuazione controllo tenuta valvole t80 = valve proving test evacuation time Ph81 t80 = tempo perdita pressione atmosferica, prova atmo- t81 = leakage time test time atmospheric sferica pressure, atmospheric test Ph82 t82 = test perdita, test riempimento t82 = leakage test filling test, filling Ph83 t80 = tempo perdita pressione gas, test pressione t83 = leakage test time gas pressure, pres sure test Ph90 Tempo attesa “mancanza gas” Gas shortage waiting time t13 = afterburn time Entering the Parameter levels By means of a proper use of the keys, it is possible to enter the various level parameters, as shown in the following flow chart: 31 The burner and consequently the LMV2x.. are factory set; the air and fuel curves as set as well. Info level To enter the Info level, proceed as follows: 1 in any menu position, press keys + and - at the same time, then the program will start again: the display will show OFF. 2 until the display will show InFo, Press the enter (InFo) key 3 then il will show the first code (167) flashing, on the right side it will show the data entered. By pressing + or - it is possible to scroll (up or down) the parameter list. If a dot-line is shown on the right, there is no enough room for complete visualisation: press enter again the data will be completely shown for 1 to 3 seconds. By pressing enter or + and- at the same time, the system will exit the parameter visualisation and go back to the flashing number. 4 32 The Info level shows some basic parameters as: Parameter Description 167 Cubic meters of fule (resettable) 162 Operating hours (resettable) 163 Device operating hours 164 Burners start-ups (resettable) 166 Total number of start-ups 113 Burner number (i.e. serial number) 107 Software version 102 Software date 103 Device serial number 104 Parameter set preassignment: Customer code 105 Parameter set preassignment: Version 143 5 Free Example: choose parameter 102 to show the date the display shows parameter 102 flashing on the left and characters ._._ on the right. 6 press InFo for 1-3 seconds: the date will appear 7 press InFo to go back to parameter “102” 8 by pressing + / -, it is possible to scroll up/down the parameter list (see table above), or, by pressing ESC or InFo for more seconds, the display will show 9 Once the last parameter is accessed (143) by pressing + , the End message will flash. 10 Press InFo for more than three seconds or for more than three seconds orto return to the normal display. 33 If a message like the one below is shown during operation, it means that the burner is locked out and the Errore code is shown (in the example “error code:4”); this message is alternating with another message Diagnostic code (in the example “diagnostic code:3”). Record the codes and find out the fault in the Error table. To perform the reset, press InFo for one second: The unit displays an event which does not lead to shutdown. The display shows current error code c: alternating with diagnostic code d: . Press InFo to return to the display of phases. Example: Error code 111 / diagnostic code 0 To reset, press InFo for a second. Record the codes and check the Error List to find the type of faults. Service level To enter the Service mode, press InFo until the display will show: The service level shows all the information about flame intensity, actuators position, number and lock codes: 34 Parameter Description 954 Flame intensity 121 % output, if set = automatic operation 922 Actuators position, 00=combustibile; 01= aria 161 Lock-outs number 701..725 Lock-outs History (see chapter 23 in the LMV2x manual) 1 2 the first parameter will be “954”: the percentage of flame is shown on the right. By pressinf + or - it is possible to scroll up/down the parameter list. Once the last parameter is accessed (143) by pressing + , the End message will blink. 3 Press InFo for more than three seconds or for more than three seconds orto return to the normal display. For further nformation, see tha LMV2 related manual. 35 SETTING GAS AND AIR FLOW RATE ATTENTION: before starting the burner up, be sure that the manual cutoff valves are open and check that the pressure upstream the gas train complies the value quoted on paragraph “Technical specifications”. Be sure that the mains switch is closed. .ATTENTION: During commissioning operations, do not let the burner operate with insufficient air flow (danger of formation of carbon monoxide); if this should happen, make the gas decrease slowly until the normal combustion values are achieved. WARNING: NEVER LOOSE THE SEALED SCREWS! OTHERWISE, THE DEVICE WARRANTY WILL BE IMMEDIATELY INVALIDATE! 3 4 1 Keys 1 Valve group 2 Cover 3 Control panel 4 Blast tube 2 Fig. 42 To perform the adjustments, unscrew the fixing screws and remove the burner’s cover (see Fig. 42-2) Startup Output The start-up heat output shall not exceed 120 kW (single stage burners) or 1/3 of nominal output (double-stage, progressive or fully modulating burners). In order to comply with these requirements, burners are provided with butterfly valve and/or slow-opening safety valve. On double-stage, progressive or modulating burners, the low flame ouptut must be higher than the minimum ouptut quoted in the performance curve (page 11). IMPORTANT! the combustion air excess must be adjusted according to the in the following chart: Recommended combustion parameters Fuel Recommended (%) CO2 Recommended (%) O2 Natural gas 9 ÷ 10 3 ÷ 4.8 LPG 11 ÷ 12 2.8 ÷ 4.3 Adjustments - brief description Check that the combustion parameters are in the suggested limits. Check the flow rate measuring it on the counter or, if it was not possible, verifying the combustion head pressure by means of a differential pressure gauge, as described on par. “Measuring the gas pressure in the combustion head” on page 15. Then, adjust the combustion by settin the “air/gas ratio” curvepoints (see the LMV2x attached manual). Set, now, the low flame output, in order to avoid the low flame output increasing too much or that the flues temperature gets too low to cause condensation in the chimney. 36 Adjusting procedure To change the burner setting during the testing in the plant, follows the next procedure, according to the burner operation. DUNGS MB-DLE gas valves group: Before starting the burner up, adjust the valves group slow opening: to set the slow opening remove cover T, reverse it upside down and use it as a toolto rotate screw VR. Decrease the ignition flow rate by screwing, increase it by unscrewing. Do not use a screwdriver on the screw VR! Note: the screw VSB must be removed only in case of replacemente of the coil (see picture). C VS T(VR) VSB RP VB . Go on adjusting air and gas flow rates: check, continuosly, the flue gas analisys, as to avoid combustion with little air; dose the air according to the gas flow rate change following the steps quoted below; acting on the pressure stabiliser of the valves group, adjust the gas flow rate in the high flame stage as to meet the values requested from the boiler/utilisation: - Multibloc MB-DLE: the valve is adjusted by means of the RP regulator after slackening the locking screw VB by a number of turns. By unscrewing the regulator RP the valve opens, screwing the valve closes. The pressure stabilizer is adjusted by operating the screw VS located under the cover C. By screwing down the pressure is increased and by unscrewing it is reduced. Note: the screw VSB must be removed only in case of replacemente of the coil. C VS T(VR) VSB VB RP Dungs Multibloc MB-DLE Pressure stabiliser is factory-set. The setting values must be locally adapted to machine conditions. Important! Follow the instructions carefully! Now adjust the pressure switches (see next par.). 37 Adjusting the combustion head The burner is adjusted in the factory with the combustion head in the position that refers to the "MAX" output. The maximum output setting refers to the “fully-ahead” position of the combustion head, as far as standard models (Fig. 44), and to “fully-backward” position for low NOx burners (Fig. 45). As for “fully-ahead” position, it means that the head is placed inside the boiler, “fully-backward” position means that the head is towards the operator. As far as the reduced output operation, progressively move the combusiton head towards the “MIN” position, rotating clockwise the VRT screw (Fig. 43). The ID index shows how much the combustion head moved. ID VRT Fig. 43 Fig. 45 - Head in “fully-backward position” Fig. 44 - Head in “fully-ahead position” Fully modulating burners To adjust the fully-modulating burners, use the CMF switch on the burner control panel (see next picture), instead of the TAB thermostat as described on the previous paragraphs about the progressive burners. Go on adjusting the burner as described before, paying attention to use the CMF switch intead of TAB. The CMF position sets the oprating stages: to drive the burner to the high-flame stage, set CMF=1; to drive it to the low-flame stage, set CMF=2. To move the adjusting cam set CMF=1 or 2 and then CMF=0. CMF = 0 CMF = 1 CMF = 2 CMF = 3 stop at the current position high flame operation low flame operation automatic operation As for the RWF setting, please refer to the related documentation. 38 Calibration of air and gas pressure switches The air pressure switch locks the control box if the air pressure is not the one requested. If it happens, unlock the burner by means of the control box unlock pushbutton, placed on the burner control panel. The gas pressure switches check the pressure to avoid the burner operate when the pressure value is not in the requested pressure range. Calibration of air pressure switch To calibrate the air pressure switch, proceed as follows: Remove the transparent plastic cap. Once air and gas setting have been accomplished, startup the burner. During the pre-purge phase o the operation, turn slowly the adjusting ring nut VR in the clockwise direction until the burner lockout, then read the value on the pressure switch scale and set it to a value reduced by 15%. Repeat the ignition cycle of the burner and check it runs properly. Refit the transparent plastic cover on the pressure switch. Calibration of low gas pressure switch As for the gas pressure switch calibration, proceed as follows: Remove the transparent plastic cap. While the burner is operating at the maximum output, test the gas pressure on the low gas pressure switch port. Slowly close the manual shut-off valve (placed upstream the pressure switch, see gas train installation diagram), until the measured pressure is reduced by 50%. Pay attention that the CO value in the flue gas does not increase. Check that the burner is operating correctly. Screw down the pressure switch adjusting ring nut until the burner lockout. Fully open the manual shut-off valve. Refit the transparent plastic cover on the pressure switch. Adjusting the maximum gas pressure switch (when provided) To calibrate the maximum pressure switch, proceed as follows according to its mounting position: 1 remove the pressure switch plastic cover; 2 if the maximum pressure switch is mounted upstreaam the gas valves: measure the gas pressure in the network, when flame is off; by means of the adjusting ring nut VR, set the value read, increased by the 30%. 3 if the maximum pressure switch is mounted downstream the “gas governor-gas valves” group and upstream the butterfly valve: light the burner, adjust it according to the procedure in the previous paragrph. Then, measure the gas pressure at the operating flow rate, downstream the “gas governor-gas valves” group and upstream the butterfly valve; by means of the adjusting ring nut VR, set the value read on step 2, increased by the 30%; 4 replace the plastic cover. PGCP Gas leakage pressure switch (witn Siemens LDU burner control/Siemens LMV Burner Management System) remove the pressure switch plastic cover; adjust the PGCP pressure switch to the same value set for the minimum gas pressure switch; replace the plastic cover. 39 PART II: OPERATION LIMITATIONS OF USE THE BURNER IS AN APPLIANCE DESIGNED AND CONSTRUCTED TO OPERATE ONLY AFTER BEING CORRECTLY CONNECTED TO A HEAT GENERATOR (E.G. BOILER, HOT AIR GENERATOR, FURNACE, ETC.), ANY OTHER USE IS TO BE CONSIDERED IMPROPER AND THEREFORE DANGEROUS. THE USER MUST GUARANTEE THE CORRECT FITTING OF THE APPLIANCE, ENTRUSTING THE INSTALLATION OF IT TO QUALIFIED PERSONNEL AND HAVING THE FIRST COMMISSIONING OF IT CARRIED OUT BY A SERVICE CENTRE AUTHORISED BY THE COMPANY MANUFACTURING THE BURNER. A FUNDAMENTAL FACTOR IN THIS RESPECT IS THE ELECTRICAL CONNECTION TO THE GENERATOR’S CONTROL AND SAFETY UNITS (CONTROL THERMOSTAT, SAFETY, ETC.) WHICH GUARANTEES CORRECT AND SAFE FUNCTIONING OF THE BURNER. THEREFORE, ANY OPERATION OF THE APPLIANCE MUST BE PREVENTED WHICH DEPARTS FROM THE INSTALLATION OPERATIONS OR WHICH HAPPENS AFTER TOTAL OR PARTIAL TAMPERING WITH THESE (E.G. DISCONNECTION, EVEN PARTIAL, OF THE ELECTRICAL LEADS, OPENING THE GENERATOR DOOR, DISMANTLING OF PART OF THE BURNER). NEVER OPEN OR DISMANTLE ANY COMPONENT OF THE MACHINE. OPERATE ONLY THE MAIN SWITCH, WHICH THROUGH ITS EASY ACCESSIBILITY AND RAPIDITY OF OPERATION ALSO FUNCTIONS AS AN EMERGENCY SWITCH, AND ON THE RESET BUTTON. IN CASE OF A BURNER SHUT-DOWN, RESET THE CONTROL BOX BY MEANS OF THE RESET PUSHBUTTON. IF A SECOND SHUT-DOWN TAKES PLACE, CALL THE TECHNICAL SERVICE, WITHOUT TRYING TO RESET FURTHER. WARNING: DURING NORMAL OPERATION THE PARTS OF THE BURNER NEAREST TO THE GENERATOR (COUPLING FLANGE) CAN BECOME VERY HOT, AVOID TOUCHING THEM SO AS NOT TO GET BURNT. OPERATION E B G H A I L D V1 M C V2 Fig. 46 - Burner’s control panel Fig. 47 - Burner modulator Key - Fig. 46 A Mains switch ON - OFF B Lockout signaling lamp C AZL user interface D Minimum gas pressure switch consent signaling lamp E High flame operation signaling lamp (or air damper opening during pre-purge stage) G Low flame operation signaling lamp H Ignition transformer in operation signaling light I EV2 opening signaling lamp L EV1 opening signaling lamp M Fuse 40 OPERATION ATTENTION: BEFORE STARTING THE BURNER UP, BE SURE THAT THE MANUAL CUTOFF VALVES ARE OPEN AND CHECK THAT THE PRESSURE VALUE UPSTREAM THE GAS TRAIN MATCHES THE VALUE ON PARAGRAPH “TECHNICAL SPECIFICATIONS”). CHECK THAT THE MAINS SWITCH IS CLOSED. CAREFULLY READ THE “WARNINGS” CHAPTER. Set to On the A main switch on the burner front panel. Check that tha control box is not in lockout position (lamp B On), eventually unlock it by pressing the Enter/InFo key on the AZL display (for further information on LMV2/AZL, please refer to the relatoed manual). Check the thermostat/pressure swicthes series enables the burner to operate. Check that the gas pressure is sufficient (if not the display AZL2.. will show a warning message). At the beginning of startup cycle, the actuator drives the air damper to its maximum opening position, then the fan motor starts up: the pre-purging phase starts. During pre-puerging, the air damper complete opening is signalled by the lamp F on the front panel. At the end of pre-purging, the air damper is driven to ignition position, the ignition transfomer is energised (signalled by lamp H on the front panel) and, few seconds later, the EV1 and EV2 gas valves are open (lamp L and I on the front panel). Few seconds later, after the gas valve opening, then the ignition transformeris de-energised (lamp H tunrs to off). The burner is now operating in low flame, later on the tow-stage operation begins and the burner increases or decreases the output directly controlled by the external thermostat (in the progressive version) ro by the output controller (P in the next picutre, only for fully-modulating burners). 41 PART III: MAINTENANCE At least once a year carry out the maintenance operations listed below. In the case of seasonal servicing, it is recommended to carry out the maintenance at the end of each heating season; in the case of continuous operation the maintenance is carried out every 6 months. WARNING: ALL OPERATIONS ON THE BURNER MUST BE CARRIED OUT WITH THE MAINS DISCONNECTED AND THE FUEL MANAUL CUTOFF VALVES CLOSED! ATTENTION: READ CAREFULLY THE “WARNINGS” CHAPTER AT THE BEGINNIG OF THIS MANUAL. ROUTINE MAINTENANCE Clean and examining the gas filter cartdrige, if necessary replace it (Fig. 48 on). Removal, examination and cleaning of the combustion head. Check the ignition and detection electrodes, clean and adjust if necessary (see Fig. 55). In case of doubr, check the detection current according to the schemes in Fig. 59. Cleaning and greasing of sliding and rotating parts. ATTENTIONwhen servicing, if it was necessary to disassemble the gas train parts, remember to execute the gas proving test, once the gas train is reassembled, according to the procedure imposed by the law in force. Removing the filter in the MULTIBLOC DUNGS MB-DLE 405..412 Check the filter at least once a year! Change the filter if the pressure difference between pressure connection 1 and 3 (Fig. 48-Fig. 49)is Dp > 10 mbar. Change the filter if the pressure difference between pressure connection 1 and 3 (Fig. 48-Fig. 49) is twice as high compared to the last check. You can change the filter without removing the fitting. 1 Interrupt the gas supply closing the on-off valve. 2 Remove screws 1 ÷ 4 using the Allen key n. 3 and remove filter cover 5 in Fig. 50. 3 Remove the filter 6 and replace with a new one. 4 Replace filter cover 5 and tighten screws 1 ÷ 4 without using any force and fasten. 5 Perform leakage and functional test, pmax. = 360 mbar. 6 Pay attention that dirt does not fall inside the valve. 2 3 2 pe 0 1 6 6 6 1 ➞ ➞ 43 34 5 pBr 1 0 5 4 pa 0 3 pe 4 pa Fig. 49 5 Fig. 48 Fig. 50 42 5 pBr Removing the filter in theMULTIBLOC DUNGS MB-DLE 415 - 420 B01 1” 1/2 - 2” Check the filter at least once a year! Change the filter if the pressure difference between pressure connection 1 and 2 (Fig. 51-Fig. 52) Dp> 10 mbar. Change the filter if the pressure difference between pressure connection 1 and 2 (Fig. 51-Fig. 52) is twice as high compared to the last check. You can change the filter without removing the fitting. 1 Interrupt the gas supply closing the on-off valve. 2 Remove screws 1 ÷ 6 (Fig. 53). 3 Change filter insert. 4 Re-insert filter housing, screw in screws 1 ÷ 6 without using any force and fasten. 5 Perform leakage and functional test, pmax. = 360 mbar. 6 Pay attention that dirt does not fall inside the valve. 0 3 2 pe 0 1 5 5 4 pa 5 pBr 1 6 1 0 Fig. 51 E D A B 4 pa Fig. 52 32 4 4 23 3 pe C Fig. 53 43 5 pBr Removing and cleaning the combustion head 1 By means of the plastic hook G, unlock the rod T (Fig. 54) which drives the butterfly valve (Fig. 54 and Fig. 55), to disconnect it from its seat. 2 Remove the screws V1, V2, V3, V4 and the screws S1 and S2 (Fig. 54). 3 Disconnect the ignition cable CA from the ignition transformer (Fig. 56). 4 Disconnect the connector CR (Fig. 57). CAUTION: during the assembling phase, before tightening screws V1, V2, V3, V4, mount and tighten screws S1 and S2. To remove the head, the operator must pull it towards himself. Once the combustione head is removed, check that the air and gas holes are not obstructed (Fig. 57 - H). Clean the combustion head by a compressed air blow or, in case of scale, scrape it off by a scratchbrush. G V1 V2 S1 LOCKED VT1 G TR G T V4 S2 VT2 UNLOCKED V3 Fig. 55 Fig. 54 H CA CR Fig. 57 Fig. 56 44 Adjusting the electrodes position ATTENTION: avoid the ignition and detection electrodes to get in touch with metallic parts (blast tube, head, etc.), otherwise the boiler’s operation would be compromised. Check the electrodes position after any intervention on the combustion head. The gap between the ignition electrode and the ground is 4÷5 mm. Ground Ignition electrode Detection electrode detection electrode Fig. 58 Checking the detection current To measure the detection signals refer to the diagrams in the picture below. If the signal is less than the indicated value, check the position of the detection electrode, the electrical contacts and if necessary replace the detection electrode. Control box Minimum detection signal Siemens LMV2 4 µA (value on display:30%) 1 2 3 4 5 Protective earth PE X10-05 Ionization probe (ION) + QRB.../ QRC... signal voltage 1 2 QRB... GND QRA... (-) X10-06 QRA... (+) L Fig. 59 Error code 93 Diagnostic code 3 Cause Sensore short-circuit Permissible length of flame detector cable (laid separately): 3 m (core-earth 100 pF / m). Extraneous lightExtraneous light Extraneous light during standby (phase 12) leads to start prevention, followed by a restart. Extraneous light during the prepurge phase leads to immediate lockout. If extraneous light occurs during the shutdown phase, the system switches to the safety phase. One repetition is permitted. This means that if the error occurs again the next time the system is shut down, the unit initiates lockout. Seasonal stop To stop the burner in the seasonal stop, proceed as follows: 1 turn the burner main switch to 0 (Off position) 2 disconnect the power mains 3 close the fuel valve of the supply line Burner disposal In case of disposal, follow the instructions according to the laws in force in your country about the “Disposal of materials”. 45 BURNER EXPLODED VIEW 46 POS. DESCRIPTION POS. DESCRIPTION 1 COVER 24.5 O RING 2 FAIRLEAD 24.6 PIN 3 FAIRLEAD 24.7 BUSH 4 FAIRLEAD 24.8 INDEX LABEL 5 FAIRLEAD 24.9 INDEX 6.1 BURNER HOUSING 25.1 GAS MANIFOLD 47 6.2 MOTOR SUPPORT PLATE 25.2 HEAD EXTENSION 6.3 FLANGED PIPE 25.3.1 DETECTION ELECTRODE 7 GENERATOR GASKET 25.3.2 IGNITION ELECTRODE 8 THREADED GAS PIPE 25.3.3 COMBUSTION HEAD 9 FAN WHEEL 25.4 IGNITION CABLE 10 GAS PRESSURE 25.5 DETECTION CABLE 11 MOTOR 26 CONNECTOR 12 GAS VALVES GROUP WITH GOVERNOR 27 CONNECTOR 13 FLANGE 28.1 IGNITION TRANSFORMER 14 PLUG 28.2 AIR PRESSURE SWITCH 15 O RING 28.3 BRACKET 16 AIR FLAP 28.4 CONTACTOR 17 COVER FIXING SCREW 28.5 CONTROL BOX 18 AIR INTAKE 29.1 ACTUATOR BRACKET 19 AIR INTAKE 29.2 ACTUATOR 20 BRACKET 29.3 ADJUSTING BUSH 21 BRACKET 30.1 FRONT CONTROL PANEL 22 GAS MANIFOLD 30.2 BOARD 23 BLAST TUBE 30.3 LIGHT 24.1 ACTUATOR 30.4 FUSE 24.2 FLANGE 30.5 SWITCH 24.3 BUTTERFLY GAS VALVE 30.6 LIGHT 24.4 COUPLING 30.7 CONTROL PANEL SPARE PARTS Desription LG/NG280 1011803 2020474 2020477 2022115 2080108 2080218 2110059 2160053 2160077 2170138 2170232 2180717 2190341 2190342 21903L3 2480096 2570112 30600P9 30600Q3 30900L0 30900L1 3501842 6050153 6050214 COVER BURNER MANAGEMENT SYSTEM - SIEMENS LMV2.. BURNER MANAGEMENT SYSTEM - SIEMENS LMV3.. USER INTERFACE/DISPLAY - SIEMENS AZL2.. DETECTION ELECTRODE INGNITION ELECTRODE GASKET AIR PRESSURE SWITCH GAS PRESSURE SWITCH IGNITION TRANSFORMER MOD. COFI IGNITION TRANSFORMER MOD. DANFOSS MOTOR VALVE GROUP Rp1 VALVE GROUP Rp1 1/4 VALVE GROUP Rp1 1/2 ACTUATOR - SIEMENS SQN14 ACTUATOR - SIEMENS RWF COMBUSTION HEAD (GAS) mod. NG COMBUSTION HEAD (L.P.G.) mod. LG BLAST TUBE S* BLAST TUBE L* COMBUSTION HEAD (GAS) mod. NG COMBUSTION HEAD (L.P.G.) mod. LG INGNITION CABLE DETECTION CABLE Code LG/NG350 1011803 2020474 2020477 2022115 2080108 2080218 2110059 2160053 2160077 2170138 2170232 2180714 2190341 2190342 21903L3 2480096 2570112 30600H3 30600H7 30900G3 30900G3** 3501841 3501844 6050153 6050214 LG/NG400 1011803 2020474 2020477 2022115 2080108 2080218 2110059 2160053 2160077 2170138 2170232 2180712 2190341 2190342 21903L3 2480096 2570112 30600H2 30600H6 30900F9 30900F9** 3501842 3501843 6050153 6050214 Spare parts for Low NOx Burners only Desription NGX280 30600Q7 30910P5 COMBUSTION HEAD (NOx) BLAST TUBE S* *S:standard L: long ** To modify the blast tube’s length, see chapter “How to modify blast tube length”. NOTE: it is recommended to mention the burner ID number on the spare parts request form. 48 Code NGX350 30600H9 30910L6 NGX400 30600H8 30910L7 ELECTRICAL WIRING DIAGRAMS See the attached wiring diagrams. Wiring diagram SE04-755 - Progressive burners Wiring diagram SE04-753 - Fully-modulating burners 49 C.I.B. UNIGAS S.p.A. Via L.Galvani, 9 - 35011 Campodarsego (PD) - ITALY Tel. +39 049 9200944 - Fax +39 049 9200945/9201269 web site: www.cibunigas.it - e-mail: [email protected] Note: Specifications and and data subject to change. Errors and omissions excepted.
advertisement
Key Features
- Microprocessor control
- Natural gas operation
- Adjustable gas/air flow
- Control panel
- Intermittent/continuous operation
- Safety features
- 65-300kW output
Frequently Answers and Questions
What is the maximum output of the Unigas IDEA NG280?
The maximum output is 300kW.
How do I adjust the gas and air flow rates?
The manual provides detailed instructions on how to adjust these settings for optimal combustion.
What type of gas is the Unigas IDEA NG280 compatible with?
This burner is designed for natural gas.