Avanti XP LED user manual

Avanti XP LED user manual
Manager operating guid e LED RKP V8.0
How to set your
system and if you wish
omit a zone
From DAY mode
Enter Manager Code
?
?
?
?
A
Select
Program
B
*
The panel will now set.
To omit a zone press Z
And then the zones you wish
to omit
How to unset your
system
Enter Manager Code
?
?
?
?
The panel is now in DAY.
How to program
chime on any
zone
From DAY mode
¯
Enter Manager Code
?
?
?
?
Select
¯
Toggle zones by
pressing KEYs 1-8
A
B
To accept
To abort
Keypad will now give a
confirmation beep and the
chime zone numbers will be lit
Quick Set
This feature allows the panel to be SET so that it overrides
the programmed exit time. Entering an access code,
selecting Program A / B or * and then pressing ¯will
cause the panel to SET within 2 seconds.
On board PA
Simultaneously depressing key’s 4 and 8 will activate a PA
thus creating a full alarm condition. This feature can be
used when the system is in DAY mode or SET
Fault during setting
If the system is unable to SET then the internal sounders
will make an error tone. The fault on the system will be
indicated by the relevant zone/PA/Tamper LED being lit. If
a zone LED is lit then ensure that all windows and doors
are closed and the zone is clear. If the fault persists then it
may be possible to omit the zone.
System Faults
If after entering your code the Tamper LED is flashing
there may be a System fault. Re-enter your code. there
are 4 possible faults indicated by the Zone LEDS flashing.
Z1 Mains Fail
Z3 Battery Low
Z2 Tel Line Fail (XP)
Z4 Service Due
Entering your code again will allow you to override the
fault, but you must inform the Engineer.
Alarm Activation
If the system has been activated then an access code
needs to be entered. To reset the system all that is
required is to re- enter an access code. If your system is
monitored you should contact your engineer to reset the
panel.
Holiday Access Code
The purpose of this code is to allow access to the property
whilst the manager is absent. The Holiday Access Code is
programmed by the Manager and is only valid until the
Manager USE’s the system. At this point the Holiday
Access Code becomes invalid and is no longer accepted by
the control panel.
User Codes
A User can perform the same operations as a Manager
except they are unable to View the Alarm Log, access the
Test Menu.
Authorize engineer (user)
A User simply enters their access code then press Z to
quit from user access, the engineer will then promptly
enter the engineer code. A timer will then start allowing 3
hours engineer access.
Installation Company contact and telephone No
0702
AvantiXP
XL8
LC
Avanti Avanti 8
How to view the
alarm log
¯
From DAY mode
Enter Manager Code
?
?
?
?
¯
From DAY mode
Enter Manager Code
?
?
?
?
Enter
Enter
2
1
Next select code to be changed
After selecting Alarm Log the zone,
PA and Tamper LED’s will show the
latest event
A flashing LED indicates the zone that
was first activated.
Any other LED lit was activated after
the first event but before system
unset.
1 2 3 4 5 6 7 8
Day
PA
Tamper
1
2
2
Jump to oldest event
3
Move one event newer
4
Jump to newest event
Z
Manager menu
Followed by
Z
User 2 access code
3
User 3 access code
4
User 4 access code
5
2
6
Holiday code
7
Duress code
Manager code
Enter 4 new digits
?
?
?
?
or
Delete access code
*
Then
Z
Manager menu
From DAY mode
¯
This returns you to DAY
& allows 3 hours
Engineer access
To accept
To abort
How to test your
alarm system
¯
Enter Manager Code
?
?
?
?
Enter Manager Code
?
?
?
?
3
2
A
B
How to authorise
Engineer access
Enter
User 1 access code
Next
Move one event older
From DAY mode
1
Enter
9
Test Menu
1
Switch bell on
6
Enter walk test
2
2
3
Switch strobe on
Z
Exit walk test
Switch speakers on 9
Zone status
0
Switch outputs off
Manager menu
Z