20G211-00 E2 User Manual

20G211-00 E2 – 2014-05-22
User Manual
G211 – 3U CompactPCI
®
Serial Quad Gigabit
Ethernet Interface
Configuration example
G211 – 3U CompactPCI® Serial Quad Gigabit Ethernet Interface
G211 – 3U CompactPCI® Serial Quad Gigabit Ethernet Interface
The G211 quad Ethernet interface is a rugged single Eurocard CompactPCI® Serial peripheral board. It can be used in combination with a CompactPCI® Serial or
CompactPCI® PlusIO CPU board in a CompactPCI® Serial or hybrid system.
It provides four Gigabit Ethernet interfaces at the front panel which can be accessed either on four RJ45 or four M12 connectors making it especially suited for applications in harsh environments. All four interfaces are controlled by one
Ethernet controller which is connected to the backplane via a x4 PCI Express® link and supports the IEEE 802.3x standard. Each interface supports a data transfer rate of 1 Gbit/s, even if all interfaces are used simultaneously. Two LEDs show the link and activity status of every interface.
The G211 is screened for extended operating temperature and prepared for conformal coating for use in harsh and mobile environments.
MEN Mikro Elektronik GmbH
2
Diagram
Diagram
Isolation
PCI‐Express‐to‐Quad‐
Ethernet Controller
PCIe 1
F Front connector
R Rear I/O connector
R
MEN Mikro Elektronik GmbH
3
Technical Data
Technical Data
Ethernet Interfaces
• Four 10/100/1000Base-T interfaces
• IEEE802.3x support
- Full-duplex flow control
- Half-duplex back pressure collision flow control
- 1 Gbit/s data transfer rate for each interface, even if all 4 interfaces are used simultaneously
• 4x2 status LEDs to signal link status and activity
Front Connections
• Four standard 8-pin RJ45 or M12 receptacle connectors
CompactPCI® Serial
• Compliance with CompactPCI® Serial PICMG CPCI-S.0 Specification
• Peripheral slot
• Host interface: One PCI Express® x4 link
- PCIe® 2.0 support
- Data rate up to 2 GB/s in each direction (5 Gbit/s per lane)
Electrical Specifications
• Isolation voltage: 1500V between Ethernet links and between Ethernet links and shield or ground
• Supply voltage/power consumption:
- +12V (-5%/+5%), 3.5 W typ/ 6 W max.
Mechanical Specifications
• Dimensions: conforming to CompactPCI® Serial specification for 3U boards
• Weight: 240 g (with heat sink)
Environmental Specifications
• Temperature range (operation):
- -40..+85°C (screened)
- Airflow: min. 1.0 m/s
• Temperature range (storage): -40..+85°C
• Relative humidity (operation): max. 95% non-condensing
• Relative humidity (storage): max. 95% non-condensing
• Altitude: -300 m to + 3,000 m
• Shock: 15 g, 11 ms
• Bump: 10 g, 16 ms
• Vibration (sinusoidal): 2 g, 10..150Hz
• Conformal coating on request
MEN Mikro Elektronik GmbH
4
Technical Data
MTBF
• MTBF: 324,639h @ 40°C according to IEC/TR 62380 (RDF 2000)
Safety
• PCB manufactured with a flammability rating of 94V-0 by UL recognized manufacturers
EMC
• Tested according to EN 55022 (radio disturbance), EN 61000-4-2 (ESD), EN
61000-4-4 (burst) and EN 61000-4-5 (surge)
Software Support
• Windows®
• Linux
• For more information on supported operating system versions and drivers see online data sheet.
MEN Mikro Elektronik GmbH
5
Configuration Options
Configuration Options
Ethernet
• Four RJ45 connectors at the front panel
• Four M12 connectors at the front panel
Operating Temperature
• Depends on system configuration
• Maximum: +85°C
• Minimum: -50°C
Cooling Concept
• Also available with conduction cooling in MEN CCA frame
Please note that some of these options may only be available for large volumes.
Please ask our sales staff for more information.
For available standard configurations see online data sheet.
MEN Mikro Elektronik GmbH
6
Product Safety
Product Safety
!
Electrostatic Discharge (ESD)
Computer boards and components contain electrostatic sensitive devices.
Electrostatic discharge (ESD) can damage components. To protect the board and other components against damage from static electricity, you should follow some precautions whenever you work on your computer.
• Power down and unplug your computer system when working on the inside.
• Hold components by the edges and try not to touch the IC chips, leads, or circuitry.
• Use a grounded wrist strap before handling computer components.
• Place components on a grounded antistatic pad or on the bag that came with the component whenever the components are separated from the system.
• Store the board only in its original ESD-protected packaging. Retain the original packaging in case you need to return the board to MEN for repair.
MEN Mikro Elektronik GmbH
7
About this Document
About this Document
This user manual is intended only for system developers and integrators, it is not intended for end users.
It describes the hardware functions of the board, connection of peripheral devices and integration into a system. It also provides additional information for special applications and configurations of the board.
The manual does not include detailed information on individual components (data sheets etc.). A list of literature is given in the appendix.
History
E1
E2
Issue Comments
First issue
Changed 500 Mbit/s to 1 Gbit/s data transfer rate
Date
2010-07-16
2014-05-22
Conventions
!
italics
bold
monospace
comment
hyperlink
IRQ#
/IRQ in/out
This sign marks important notes or warnings concerning the use of voltages which can lead to serious damage to your health and also cause damage or destruction of the component.
This sign marks important notes or warnings concerning proper functionality of the product described in this document. You should read them in any case.
Folder, file and function names are printed in italics.
Bold
type is used for emphasis.
A monospaced
font type is used for hexadecimal numbers, listings, C function descriptions or wherever appropriate. Hexadecimal numbers are preceded by "0x".
Comments embedded into coding examples are shown in green color.
Hyperlinks are printed in blue color .
The globe will show you where hyperlinks lead directly to the Internet, so you can look for the latest information online.
Signal names followed by "#" or preceded by a slash ("/") indicate that this signal is either active low or that it becomes active at a falling edge.
Signal directions in signal mnemonics tables generally refer to the corresponding board or component, "in" meaning "to the board or component", "out" meaning
"coming from it".
Vertical lines on the outer margin signal technical changes to the previous issue of the document.
MEN Mikro Elektronik GmbH
8
About this Document
Legal Information
Changes
MEN Mikro Elektronik GmbH ("MEN") reserves the right to make changes without further notice to any products herein.
Warranty, Guarantee, Liability
MEN makes no warranty, representation or guarantee of any kind regarding the suitability of its products for any particular purpose, nor does MEN assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including, without limitation, consequential or incidental damages. TO THE EXTENT APPLICABLE, SPECIFICALLY EXCLUDED ARE ANY IMPLIED
WARRANTIES ARISING BY OPERATION OF LAW, CUSTOM OR USAGE, INCLUDING WITHOUT
LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE OR USE. In no event shall MEN be liable for more than the contract price for the products in question. If buyer does not notify MEN in writing within the foregoing warranty period, MEN shall have no liability or obligation to buyer hereunder.
The publication is provided on the terms and understanding that:
1. MEN is not responsible for the results of any actions taken on the basis of information in the publication, nor for any error in or omission from the publication; and
2. MEN is not engaged in rendering technical or other advice or services.
MEN expressly disclaims all and any liability and responsibility to any person, whether a reader of the publication or not, in respect of anything, and of the consequences of anything, done or omitted to be done by any such person in reliance, whether wholly or partially, on the whole or any part of the contents of the publication.
Conditions for Use, Field of Application
The correct function of MEN products in mission-critical and life-critical applications is limited to the environmental specification given for each product in the technical user manual. The correct function of MEN products under extended environmental conditions is limited to the individual requirement specification and subsequent validation documents for each product for the applicable use case and has to be agreed upon in writing by MEN and the customer. Should the customer purchase or use MEN products for any unintended or unauthorized application, the customer shall indemnify and hold MEN and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim or personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that MEN was negligent regarding the design or manufacture of the part. In no case is MEN liable for the correct function of the technical installation where MEN products are a part of.
Trademarks
All products or services mentioned in this publication are identified by the trademarks, service marks, or product names as designated by the companies which market those products. The trademarks and registered trademarks are held by the companies producing them. Inquiries concerning such trademarks should be made directly to those companies.
Conformity
MEN products are no ready-made products for end users. They are tested according to the standards given in the
Technical Data and thus enable you to achieve certification of the product according to the standards applicable in your field of application.
MEN Mikro Elektronik GmbH
9
About this Document
RoHS
Since July 1, 2006 all MEN standard products comply with RoHS legislation.
Since January 2005 the SMD and manual soldering processes at MEN have already been completely lead-free.
Between June 2004 and June 30, 2006 MEN’s selected component suppliers have changed delivery to RoHScompliant parts. During this period any change and status was traceable through the MEN ERP system and the boards gradually became RoHS-compliant.
WEEE Application
The WEEE directive does not apply to fixed industrial plants and tools. The compliance is the responsibility of the company which puts the product on the market, as defined in the directive; components and sub-assemblies are not subject to product compliance.
In other words: Since MEN does not deliver ready-made products to end users, the WEEE directive is not applicable for MEN. Users are nevertheless recommended to properly recycle all electronic boards which have passed their life cycle.
Nevertheless, MEN is registered as a manufacturer in Germany. The registration number can be provided on request.
Copyright © 2014 MEN Mikro Elektronik GmbH. All rights reserved.
Germany
MEN Mikro Elektronik GmbH
Neuwieder Straße 3-7
90411 Nuremberg
Phone +49-911-99 33 5-0
Fax +49-911-99 33 5-901
E-mail [email protected]
www.men.de
MEN Mikro Elektronik GmbH
France
MEN Mikro Elektronik SAS
18, rue René Cassin
ZA de la Châtelaine
74240 Gaillard
Phone +33 (0) 450-955-312
Fax +33 (0) 450-955-211
E-mail [email protected]
www.men-france.fr
USA
MEN Micro Inc.
860 Penllyn Blue Bell Pike
Blue Bell, PA 19422
Phone (215) 542-9575
Fax (215) 542-9577
E-mail [email protected]
www.menmicro.com
10
Contents
Contents
1.2 Integrating the Board into a System . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
2.4 CompactPCI Serial Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3.1 Literature and Web Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Ethernet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
MEN Mikro Elektronik GmbH
11
Figures
Figure 2. Map of the board with RJ45 front connectors – top view . . . . . . . . . . 15
Figure 3. Map of the board with M12 front connectors – top view . . . . . . . . . . . 15
MEN Mikro Elektronik GmbH
12
Tables
Signal mnemonics of Ethernet front-panel connectors. . . . . . . . . . . . . 17
Pin assignment of Ethernet front-panel connectors . . . . . . . . . . . . . . . 18
Pin assignment of Ethernet front-panel connectors . . . . . . . . . . . . . . . 18
Pin assignment of CompactPCI Serial P1 connector . . . . . . . . . . . . . . 20
MEN Mikro Elektronik GmbH
13
1
Getting Started
Getting Started
This chapter gives an overview of the board and some hints for first installation in a system.
1.1
Map of the Board
Figure 1. Map of the board – front panels
G211 with 4 RJ45 G211 with 4 M12
® ®
L A
1
X1
L A
2
X2
L A
1
X1
L A
2
X2
X3
X4
L A
4
L A
3
X3
X4
L A
4
L A
3
G211 G211
MEN Mikro Elektronik GmbH
14
Figure 2. Map of the board with RJ45 front connectors – top view
Heat Sink
RJ45 Front
Connectors
Getting Started
Ethernet Controller CompactPCI Serial Connector P1
Figure 3. Map of the board with M12 front connectors – top view
Heat Sink
M12 Front
Connectors
MEN Mikro Elektronik GmbH
Ethernet Controller CompactPCI Serial Connector P1
15
Getting Started
1.2
Integrating the Board into a System
You can use the following "check list" when installing the G211 in a CompactPCI
Serial system for the first time.
Power-down the system.
Insert the G211 into a peripheral slot of your CompactPCI Serial system, making sure that the CompactPCI Serial connectors are properly aligned.
Note: The peripheral slots of every CompactPCI Serial system are marked by a circle on the backplane and/or at the front panel.
Power-up the system.
You can now install driver software.
1.3
Installing Driver Software
For a detailed description on how to install driver software please refer to the respective documentation.
You can find any driver software available for download on MEN’s website .
MEN Mikro Elektronik GmbH
16
2
Functional Description
Functional Description
!
2.1
Power Supply
The G211 is supplied with a primary +12V voltage via the CompactPCI Serial connector P1.
2.2
Ethernet Interfaces
The G211 has four Gigabit Ethernet interfaces controlled by the Intel 82580 Dual/
Quad Gigabit Ethernet Controller. All channels support 10/100/1000Base-T physical layers, and half-duplex and full-duplex operation complying with
IEEE802.3x. Each of the four channels reach a performance of 1 Gbit/s read and/or write, even when all four interfaces are used simultaneously.
The unique MAC address for every interface is set at the factory and should not be changed. Any attempt to change this address may create node or bus contention and thereby render the board inoperable. The MAC addresses on G211 are:
• Interface X1:
0x 00 C0 3A 9D 0x xx
• Interface X2:
0x 00 C0 3A 9D 1x xx
• Interface X3:
0x 00 C0 3A 9D 2x xx
• Interface X4:
0x 00 C0 3A 9D 3x xx where "00 C0 3A" is the MEN vendor code, "9D" is the MEN product code. The last four digits depend on the interface and the serial number of the product. The serial number is added to the offset, for example for X2:
• Serial number 0042:
0x xx xx = 0x1000 + 0x002A = 0x 10 2A.
(See
Chapter 3.2 Finding out the Product’s Article Number, Revision and Serial
.)
2.2.1
Connection
The G211 is available in two standard versions: one provides four standard RJ45 connectors and one four 8-pin M12 connectors at the front panel.
The pin assignments correspond to the Ethernet specification IEEE802.3.
Table 1. Signal mnemonics of Ethernet front-panel connectors
Signal
BI_Dx+/-
RX+/-
TX+/in/out in
Direction
out
Function
Differential pairs of data lines for 1000Base-T
Differential pair of receive data lines for 10/
100Base-T
Differential pair of transmit data lines for 10/
100Base-T
MEN Mikro Elektronik GmbH
17
Functional Description
Pin Assignment of RJ45 Connectors
Connector types:
• Modular 8/8-pin mounting jack according to FCC68
• Mating connector:
Modular 8/8-pin plug according to FCC68
Table 2. Pin assignment of Ethernet front-panel connectors
1
8
1
2
3
4
5
6
7
8
1000Base-T 10/100Base-T
BI_DA+ TX+
BI_DA-
BI_DB+
TX-
RX+
BI_DC+
BI_DC-
BI_DB-
BI_DD+
BI_DD-
-
-
RX-
-
-
Pin Assignment of M12 Connectors
Connector types:
• 8-pin M12 receptacle A-coded 90°
• Mating connector:
8-pin M12 plug A-coded 90°
Table 3. Pin assignment of Ethernet front-panel connectors
6
7
8
1
5
4
3
2
1
2
3
4
5
6
7
8
1000Base-T 10/100Base-T
BI_DC-
BI_DD+
BI_DD-
BI_DA-
BI_DB+
BI_DA+
BI_DC+
BI_DB-
TX-
RX+
TX+
-
RX-
MEN Mikro Elektronik GmbH
18
Functional Description
2.3
Status LEDs
The front panel includes two status LEDs for each channel. They signal the link and activity:
Table 4. Status LEDs
LED Color
Yellow
Green
LED State
Blinking
On
Function
Activity (RX and TX)
Link (all speeds)
MEN Mikro Elektronik GmbH
19
Functional Description
2.4
CompactPCI Serial Interface
The G211 uses up to four PCI Express lanes at the backplane according to the
CompactPCI Serial specification (PICMG CPCI-S.0, proposed standard under development).
Connector type of P1:
• 72-pin Airmax VS 4 pair, right angle header, 6 IMLA with end walls
See the following table for the pin assignment of the P1 connector:
Table 5. Pin assignment of CompactPCI Serial P1 connector
A
1
PE_
Rx03-
GND
-
-
-
PE_
Rx03+
PE_
Rx01-
-
-
PCIE_
EN#
GND
PE_
Rx01+
GND
-
GND
PE_
Tx03-
GND
-
GA2
-
PE_
Tx03+
PE_
Tx01-
-
-
RST_
IN#
GND
PE_
Tx01+
GND
-
GND
GND +12V +12V GND +12V +12V
L K J I H G
PE_
Rx02-
GND
PE_
Rx02+
PE_
Rx00-
PE_
REFCLK-
PE_
REFCLK+
GA1 -
GND
PE_
Rx00+
GND
-
-
GND
F
-
+12V
E
PE_
Tx02-
GND
-
GND
GA0
IPM-
B_SDA
+12V GND
D C
PE_
Tx02+
PE_
Tx00-
-
-
IPMB_
SCL
-
B
GND
PE_
Tx00+
GND
GND
-
-
A
6
5
4
3
2
1
For a more detailed description of the signals refer to the CompactPCI Serial specification.
MEN Mikro Elektronik GmbH
20
3
Appendix
Appendix
3.1
Literature and Web Resources
• G211 data sheet with up-to-date information and documentation: www.men.de/products/02G211-.html
3.1.1
Ethernet
• Intel 82580 Dual/Quad Gigabit Ethernet Controller www. intel.com
• ANSI/IEEE 802.3-1996, Information Technology - Telecommunications and
Information Exchange between Systems - Local and Metropolitan Area Networks - Specific Requirements - Part 3: Carrier Sense Multiple Access with Collision Detection (CSMA/CD) Access Method and Physical Layer Specifications;
1996; IEEE www.ieee.org
• Charles Spurgeon's Ethernet Web Site
Extensive information about Ethernet (IEEE 802.3) local area network (LAN) technology.
www.ethermanage.com/ethernet/
• InterOperability Laboratory, University of New Hampshire
This page covers general Ethernet technology.
www.iol.unh.edu/services/testing/ethernet/training/
3.2
Finding out the Product’s Article Number, Revision and
Serial Number
MEN user documentation may describe several different models and/or design revisions of the G211. You can find information on the article number, the design revision and the serial number on two labels attached to the board.
• Article number: Gives the product’s family and model. This is also MEN’s ordering number. To be complete it must have 9 characters.
• Revision number: Gives the design revision of the product.
• Serial number: Unique identification assigned during production.
If you need support, you should communicate these numbers to MEN.
Figure 4. Labels giving the product’s article number, revision and serial number
Complete article number
Revision number
Serial number
MEN Mikro Elektronik GmbH