Advertisement
Advertisement
Ventilation Test Instruments 9555 Menu Structure and Quick Reference Application Note TSI-145 Pressure Ports Battery Indicator Additional Messages Primary Parameter Activity Area Secondary Parameters Soft Key Indicators Soft Keys Keypad Functions ON/OFF Key Press to turn the AIRFLOW 9555 on and off. During the power up sequence the display will show the following: Model Number, Serial Number, Software Revision and Last Date Calibrated. Arrow (ST) Keys Press to scroll through choices while setting a parameter. Pressing the ST keys simultaneously will lock the keypad to prevent unauthorized adjustments to the instruments. To unlock the keypad, press the ST keys simultaneously. (Enter) Key Press to accept a value or condition. Arrow (gor h) and Menu Soft Keys Press arrow keys to change choices while setting a parameter. Press the Menu soft key to select the Menu selections, which are Display Setup, Pressure Zero, Settings, Flow Setup, Actual/Std Set up, Data Logging, Applications, Calibration and Printer. Main Soft Keys Next Test • Increments to the next available test ID. Menu • Accesses the main and sub-menus Stats • Displays the average, minimum, and maximum readings of the current Test ID. o Statistics can also be viewed from the Data Logging menu. Common Terms Sample Consists of all of the measurement parameters stored at the same time. Test ID A group of samples. The statistics (average, minimum, maximum, and count) are calculated for each test ID. The maximum number of test IDs is 100. Time Constant The time constant is an averaging period. It is used to dampen the display. If you are experiencing fluctuating flows, a longer time constant will slow down those fluctuations. The display will update every second, but the displayed reading will be the average over the last time constant period. For example, if the time constant is 10 seconds, the display will update every second, but the displayed reading will be the average from the last 10 seconds. This is also referred to as a “moving average”. Logging Interval The logging interval is a frequency period that the instrument will log readings. For example, if the logging interval is set to 30 minutes, each sample will be the average of the last 30 minutes. Log Mode/Log Settings You can set Log Mode to Manual, Auto-save, Cont-key, Cont-time, Program 1 or Program 2. • Manual mode does not automatically save data, but instead prompts the user to save a sample. • In Auto-save mode, the user manually takes samples that are automatically logged. • In Cont-key mode, the user starts taking readings and logging by pressing the key. The instrument will continue taking measurements until the key is pressed again. • In Cont-time mode, the user starts taking readings by pressing the key. The instrument will continue taking samples until a set period of time has passed. • Auto-save, Cont-Key and Cont-time modes have the following additional Log Settings: Log Settings Mode Auto-save Log Interval Cont-key Log Interval Cont-time Log Interval Test Length • Pressing the ST keys simultaneously will lock the keypad to prevent unauthorized adjustments to the instruments. To unlock the keypad, press the ST keys simultaneously. -2- • • • DISPLAY SETUP When set to ON, measurement will be displayed as a secondary parameter (up to 4 can be displayed) When set to PRIMARY, measurement will be the large number on the display When set to OFF, measurement will not be displayed DISPLAY SETUP Velocity *ON Flow OFF Pitot Velocity OFF Pressure ON Temperature ON Baro Press OFF Settings menu is where you can adjust the general settings. Use the g or h soft keys to adjust the settings for each option and use the key to accept settings. SETTINGS ON PRIMARY OFF To zero the pressure reading, select Pressure Zero. Language Beeper Select Units Time Constant Contrast Set Time Set Date Time Format Date Format Number Format Backlight Auto Off ---- MENU Zero Press Display Setup Settings Flow Setup Actual/Std Setup Data Logging Zero CO Applications Calibration Discover Printer This function identifies and partners the instrument with the model 8934 Bluetooth portable printer 9555 Menu Structure English Disable 1 Second 5 09:14 AM 10/31/08 12 hr LANGUAGE English German French Spanish Swedish Finnish Dutch Italian FLOW TYPE SELECT UNITS Temperature °F Velocity ft/min Flow CFM Heatflow BTU/h Pressure in.H2O Baro Press in.Hg MM/DD/YY XX,XXX.YY Auto Enable ---- Round duct Rect duct Duct area Press/Kfact Horn Air cone FLOW SETUP Flow Type Round Duct Enter Settings ENTER SETTINGS See Next Page APPLICATIONS Draft Rate Heatflow Turbulence % Outside Air If a CO probe is attached, this function will zero the CO sensor 12.0 in dia ACTUAL/STD SETUP Setting Standard Temp source Entered Standard temp 70.0 F Standard Press 29.92 in.Hg SETTING Standard Actual TEMP SOURCE CALIBRATION Calibrate Temp Calibrate Vel Calibrate %RH Calibrate Press Calibrate B.P. Calibrate CO2 Calibrate CO Restore Factory Cal Entered Temp Probe Thermocouple 1 Thermocouple 2 RESTORE FACTORY CAL Restore Temp Restore Vel Restore %RH Restore Press Restore B.P. Restore CO2 Restore CO RESTORE TEMP Are you Sure? YES NO 70°F • • • • MEASUREMENTS Measurements being logged are independent of measurements on the display When set to ON, measurement will be logged to memory When set to DISPLAY, measurement will be logged to memory if it is visible on the main running screen When set to OFF, measurement will not be logged to memory DATA LOGGING Measurements Log Mode Manual Log Settings Choose Test Test 001 Name Test View Data Delete Data % Memory MEASUREMENTS Temperature DISPLAY Velocity DISPLAY Flow DISPLAY Heatflow OFF Pressure DISPLAY Baro Press ON ON DISPLAY LOG INTERVAL SAMPLE TIME LOG MODE 00:05 Min:Sec Manual Auto-save Cont.-key Cont.-time Program 1 Program 2 OFF If Log Mode is set to Autosave, Sample Time can be adjusted. LOG SETTINGS Log Interval Test Length 00:01 00:00:01 OR CHOOSE TEST Test 001 Test 002 Test 003 Test 004 Test 005 Test 006 Test 007 Test 008 Test 009 Test 010 --- ---NEW 00:05 Min:Sec If Log mode is set to Cont.time or Cont.-key, then the log interval and test length can be adjusted NAME TEST 9 Samples 7 Samples 0 Samples 0 Samples 0 Samples 0 Samples 0 Samples 0 Samples 0 Samples 0 Samples Test 001 TEST LENGTH 00 : 00 : 05 Day:Hour:Min 0123456789 ABCDEFGH I J KLMNOPQRST UVWXYZ_← VIEW DATA Choose Test Test 001 View Stats View Samples Print Test SAVE DATES TEST 001 Pressure Avg 35.4 Pa Min 27.4 Pa Max 47.9 Pa # Samples 3 10/31/08 07:01:39 AM PRINT DELETE ALL DELETE TEST Are you sure? MEMORY YES Test ID 83 % Sample 92 % 9555 Menu Structure DELETE DATA Delete All Delete Test Delete Sample NO Test 001 Test 002 Test 003 Test 004 Test 005 Test 006 Test 007 Test 008 Test 009 Test 010 --- ---DATES 8 Samples 5 Samples 0 Samples 0 Samples 0 Samples 0 Samples 0 Samples 0 Samples 0 Samples 0 Samples DELETE SAMPLE → DELETE SAMPLE Test 001 Test 002 Test 003 Test 004 Test 005 Test 006 Test 007 Test 008 Test 009 Test 010 --- ---DATES 8 Samples 5 Samples 0 Samples 0 Samples 0 Samples 0 Samples 0 Samples 0 Samples 0 Samples 0 Samples Test 002 Sample 5 10/31/08 04:55:03 PM DELETE TSI Incorporated – 500 Cardigan Road, Shoreview, MN 55126 U.S.A Website: www.tsi.com USA Tel: +1 800 874 2811 E-mail: [email protected] UK Tel: +44 149 4 459200 E-mail: [email protected] Website: www.tsiinc.co.uk France Tel: +33 491 95 21 90 E-mail: [email protected] Website: www.tsiinc.fr Website: www.tsiinc.de Germany Tel: +49 241 523030 E-mail: [email protected] India Tel: +91 80 41132470 E-mail: [email protected] China Tel: +86 10 8260 1595 E-mail: [email protected] Contact your local TSI Distributor or visit our website www.tsi.com for more detailed specifications. 1/09 Copyright © 2009 by TSI Incorporated Printed in U.S.A ">
Advertisement