Energy Management - Elblinger Elektronik GmbH

Energy Management - Elblinger Elektronik GmbH
Energy Management
Energy Meter
Energy Meter
Power Analyzer
Multifunction Meter
EM1-DIN
EM2-DIN
WM1-DIN
WM12-DIN
89 x 35 x 58.5
1-phase energy meter.
1-phase system.
Active energy
measurement.
89 x 107 x 58.5
1 or 3-phase energy
meter.
1-phase, 3-phase,
3 or 4 wires.
Active reactive energy
metering (partial and
total).
89 x 71.5 x 58.5
1 or 3-phase power
analayzer.
1-phase, 3-phase,
3 or 4 wires.
Measurement of:
VL-N or VL-L, A, W, VA,
var, Wh, VAh, varh.
90 x 107 x 64
3-phase multifunction
power indicator.
System: VLL, VLN, An,
VA, VAdmd, Wdmd, W,
var, PF, Hz.
Max: A, Wdmd
Single phase: VLL, VLN,
A, VA, W, var, PF
Range code
230 VAC - 22.5 AAC
[AV8]
250/433 VAC - 5 AAC
[AV5]
400/660VL-L/5(6)AAC
[AV5]
100/208VL-L/5(6)AAC
[AV6]
Accuracy
Display
Class2 (EN61036)
5+1 digits
Electromech. display
±1% RDG
6-digits backlighted
LCD
400 VAC(1-phase)/500
VAC(3-phase)-5/27AAC
3-phase system with
neutral [27A]. As above
but for measurement
on 3-phase without
neutral [TX instead of PX]
±2% fs ±0.5% (V, A)
3-digits red LED
Types
Dimensions
(mm) H x W x D
Function
Input Specifications
Sampling Rate
Class 0.5 (V-A)
3x3 DGT
LED
1.5 samples/s
Output Specifications
Serial communication
Pulse
RS 485 output +
1 relay NO [XS]
Standard [XX]
1 pulse output (on
request): 10 pulse/kWh
Alarm
1 relay output (driven
only by serial comm.)
RS 485 (1-phase 3-phase
system with neutral [RX])
RS 485 (1-phase 3-phase
system without neutral
[SX]);
both instead of”PX”
1 programmable open
collector pulse out [PX]*
1 SSR alarm ouput
[1]** instead of O
(no alarm)
RS 485 port (on
request) [S]
115 VAC [C]
230 VAC [D]
24 VAC [A]
48 VAC [B]
115 VAC [C]
230 VAC [D]
CE
General Specifications
Power supply
230 VAC [D]
Approvals/Marks
CE
24 VAC [A]
48 VAC [B]
115 VAC [C]
230 VAC [D]
CE
CE
References
* Only without alarm
** Only without pulse
No serial
24 VAC
Output
48 VAC
115 VAC
230 VAC
Serial
24 VAC
Output
48 VAC
115 VAC
230 VAC
EM1-DIN AV8 1 D XX
EM1-DIN AV8 1 D PX
WM1-DIN 27A A D O PX
WM1-DIN 27A A D O XX
EM2-DIN AV5 3 A XX
EM2-DIN AV5 3 B XX
EM2-DIN AV5 3 C XX
EM2-DIN AV5 3 D XX
EM2-DIN AV5 3 A XS
EM2-DIN AV5 3 B XS
EM2-DIN AV5 3 C XS
EM2-DIN AV5 3 D XS
WM1-DIN 27A A C O XX
WM1-DIN 27A A D O XX
WM1-DIN 27A A C O RX
WM1-DIN 27A A D O RX
Ordering References
See pag. 103
86
Energy Management
Power Analyzer
Energy Meter
Energy Meter
WM2-DIN
EM3-DIN
EM4-DIN
Types
Dimensions (mm) H x W x D
Description
Function
89 x 107 x 58.5
1 or 3-phase power analayzer.
1-phase, 3-phase,
3 or 4 wires.
Measurement of: kW,
kvar PF, VL-L, VL-N, A,
kWh tot/par, kvarh
tot/par.
162.5 x 90 x 63
MODULAR
2-phase, 3-phase
3 or 4 wires energy meter.
Direct connection up to 90 A.
6+1 dgt electromechanical display.
162.5 x 90 x 63
MODULAR
3-phase energy meter.
Direct connection up to 90 A.
Back-lighted LCD display.
31/2 dgt istantaneous
variables read out, 8+ 71/2 dgt
energy read out Measurement of
system and phase variables,
energy by timeperiods,
m3 H2O and m3 GAS.
208VL-L[AV8], 400VL-L[AV9],
660VL-L[AV3]/20(90)AAC.
3-phase unbalanced
load [3]
100VL-L[AV6], 208VL-L[AV4],
400VL-L[AV5], 660VL-L[AV7]
5(10) AAC;
208VL-L[AV0],400VL-L[AV1],
660VL-L[AV3] 20(90) AAC;
Class 2: (EN61036)
Class 3: (EN61268)
Class 1: (EN61036)
Class 2: (EN61268)
Dual pulse outputs
(NPN transistor) [O]
Dual pulse output
module (NPN trans.) [O]
1 alarm output module [O] (NPN
trans.) 30 VDC//100 mA Max.
RS422/485 serial port [SO]
Input Specifications
Range code
433 VAC - 5 AAC
[AV5]
Accuracy
Active energy
Reactive energy
Display
±1% fs
3-digits backlighted
LCD (6-digits for energy)
Output Specifications
Out 1 (Pulse)
1 programmable open
collector pulse out [P]
Out 1 (Alarm)
Out 2
(Serial communication)
Inputs
RS 485 output [PS]
Standard [PX]
2 digital inputs module
General Specifications
Power supply
24 VAC [A]
48 VAC [B]
115 VAC [C]
230 VAC [D]
Self power supply [X]:
400VAC 208VAC VL-L
Auxiliary power supply:
230VAC[D], 115VAC[C]
Approvals/Marks
CE
CE
Self power supply:
400VAC 208VAC VL-L
Auxiliary power supply:
230[D], 115[C], 48[B],
24 [A]VAC 18 to 60 VDC [4]
CE
See pag. 102
See pag. 102
References
WM2-DIN AV5 3 A P X
WM2-DIN AV5 3 B P X
WM2-DIN AV5 3 C P X
WM2-DIN AV5 3 D P X
WM2-DIN AV5 3 A P S
WM2-DIN AV5 3 B P S
WM2-DIN AV5 3 C P S
WM2-DIN AV5 3 D P S
Ordering References
CARLO GAVAZZI Automation Components
Specifications are subject to change without notice.
87
Energy Management
Types
Dimensions
(mm) H x W x D
Description
Function
Power Analyzer
Power Transducer
Power Transducer
WM22-DIN
SPT-90
PQT-90
162.5 x 90 x 63
MODULAR
3-phase power analyzer.
Direct connection up to 90 A.
Back-lighted LCD display.
4 x 31/2 dgt istantaneous
variables read out,
71/2 dgt energy read out.
Measurement of system
and phase variables.
Measurement of THD.
90 x 90 x 138
MODULAR
3-phase transducer. 1-phase,
3-phase 3 or 4 wires.
Measurement of: W, Wdmd, VA,
var, PF, Wh, VAh, varh, VL-L sys,
VL1-N, VL2-N, VL3-N, Hz.
Programming unit or
programming software
90 x 90 x 138
MODULAR
Power quality transducer.
32 bit µP based. Alarm
outputs, SMS messages.
Measurement of all
istantaneous variables.
Energy, water and gas
metering. 2MB memory+
Real time clock (on request).
100VL-L[AV6], 208VL-L[AV4],
400VL-L[AV5],660VL-L[AV7]
5(10) AAC;
208VL-L[AV0],400VL-L[AV1],
660VL-L[AV3] 20(90) AAC;
100VAC 1A[AV1]; 100VAC
5A[AV3]; 433VAC 1A
[AV4]; 433VAC 5A[AV5];
690VAC 5A[AV7]
240/415 VAC-1/5 AAC [AV5]
400/690 VAC-1/5 AAC [AV7]
±5% fs
class 0.5 (V-A)
Input Specifications
Range code
Accuracy
Active energy
Reactive energy
Sampling Rate
Class 1: (EN61036)
Class 2: (EN61268)
10 samples /s
Output Specifications
Out 1 (Pulse)
Out 1 (Alarm)
Out 2 (Analogue)
Out 2
(Serial communication)
Inputs
Options
Single /dual pulse,
open collector
Single/dual alarm
setpoint relay
Single/dual analogue
output
Up to 2 single/dual open
collector or relay modules
Up to 2 single/dual open
collector or relay modules
RS485 multidrop
birectional
3 digital inputs
Programming key-pad
[K]; RS232 Port [S]
RS 422/485 port, RS232 port +
RTC+2MB data or RS232+RTC
Up to 6 digital inputs
Up to 2 single/dual
analog. output modules
Self power supply:
400VAC 208VAC VL-L
Auxiliary power supply:
230[D], 115[C], 48[B],
24 [A]VAC 18 to 60
VDC [4]
CE
18 to 60 VAC/DC [L]
90 to 260 VAC/DC [H]
18 to 60 VAC/DC [L]
90 to 260 VAC/DC [H]
CE - UL - CSA
CE
See pag. 102
See pag. 103
See pag. 103
Dual pulse output
module (NPN trans.)[O]
1 alarm output module [O]
(NPN tr) 30 VDC//100 mA Max.
1 analogue output :
0 to 20 mADC [A1],
or 0 to 10 VDC [V1]
RS422/485 serial port
[SO]
General Specifications
Power supply
Approvals/Marks
Ordering References
88
Energy Management
Energy Meter
Multifunction Meter
Power Analyzer
EM2-96
WM12-96
WM2-96
Types
Dimensions
(mm) H x W x D
Description
96 x 96 x 124
MODULAR
3-phase energy meter.
1-phase, 3-phase,
3 or 4 wires.
Active reactive energy
metering (partial and total).
96 x 96 x 46
3-phase multifunction
power indicator.
System: VLL, VLN, An,
VA, VAdmd, Wdmd, W,
var, PF, Hz.
Max: A, Wdmd
Single phase: VLL, VLN,
A, VA, W, var, PF
96 x 96 x 124
MODULAR
3-phase power analyzer.
1-phase, 3-phase,
3 or 4 wires.
Measurements of: kW,
kvar, PF, kWh, kvarh,
A, VL-L , VL1-N, avg
VL2-N, VL3-N.
433 VACL-L-5 AAC[AV5]
[AC1014]; 690L-L VAC5 AAC [AV7] [AC1015]
±1% fs RDG
6-digit backlighted
LCD
3 times /s
400/660VL-L/5(6)AAC [AV5]
100/208VL-L/5(6)AAC [AV6]
Class 0.5 (V-A)
3x3 DGT
LED
1.5 samples/s
433 VACL-L-5 AAC[AV5]
[AC1014]; 690L-L VAC5 AAC [AV7] [AC1015]
±0.5% fs (V, A)
3-digit backlighted LCD
(6-digits for energy).
3 times /s
RS 422/485 port
RS 485 port (on request) [S]
RS 422/485 port
Input Specifications
Range Code
Accuracy
Display
Sampling Rate
Output Specifications
Serial communication
output
Alarm output
Pulse output
Single relay SPDT;
dual relay SPDT;
Single NPN transistor;
dual NPN transistor
Single NPN transistor;
dual NPN transistor;
Single relay SPDT;
dual relay SPDT
General Specifications
Power supply
Approvals/Marks
Note
24 VAC
48 VAC
115VAC
230 VAC
18 to 60 VAC/DC
90 to 260 VAC/DC
CE - UL - CSA
The alarm outputs are
driven only by the
serial communication.
24 VAC [A]
48 VAC [B]
115 VAC [C]
230 VAC [D]
CE
24 VAC
48 VAC
115VAC
230 VAC
18 to 60 VAC/DC
90 to 260 VAC/DC
CE - UL - CSA
See pag. 102
See pag. 103
See pag. 102
Ordering References
CARLO GAVAZZI Automation Components
Specifications are subject to change without notice.
89
Energy Management
Types
Dimensions
(mm) H x W x D
Description
Power Analyzer
Utility Meter
Power Analyzer
Power Analyzer
WM23-96
WM24-96
WM3-96
WM4-96
96 x 96 x 140
3-phase power quality
analyzer
System: VLN, VLL, An,
VA, VAdmd, Wdmd, W,
var, PF, Hz,
Single phase: VLN, VLL,
A, W, var, PF, THD.
96 x 96 x 140
3-phase universal
utility meter
System: VLN,VA, VAdmd,
Wdmd, W, var, PF, Hz,
total/partial Wh,
total/partial varh, gas,
H2O. Single phase: VLN,
A, W, var, PF
96 x 96 x 124
MODULAR
3-phase power quality
analyzer 32 bit µP
based. 1-phase,
3-phase, 3 or 4 wires.
Measurements of: kW,
kvar, PF, kWh, kvarh,
A, VL-L , VL1-N, avg
VL2-N, VL3-N, THD,
VL1, VL2, VL3, Hz,
Wdmd, VAdmd.
96 x 96 x 124
MODULAR
Universal utility meter
and power analyzer.
32 bit µP based.
Load profile indication.
Alarm outputs,
SMS messages.
Measurement of all
istantaneous variables.
Energy, water and gas
meter.
57/100VL-L/5(6)AAC [AV6],
120/208VL-L/5(6)AAC
[AV4],
230/400VL-L/5(6)AAC
[AV5],
380/660VL-L/5(6)AAC
[AV7]
Class 0.5 (V-A)
4x3 1/2 DGT
LCD (back lighted)
1.5 samples/s
57/100VL-L/5(6)AAC [AV6],
120/208VL-L/5(6)AAC
[AV4],
230/400VL-L/5(6)AAC
[AV5],
380/660VL-L/5(6)AAC
[AV7]
Class 0.5 (V-A)
4x3 1/2 DGT
LCD (back lighted)
1.5 samples/s
433 VAC-1/5 AAC [AV5]
690 VAC-1/5 AAC [AV7]
433 VAC-1/5 AAC [AV5]
690 VAC-1/5 AAC [AV7]
±0.5% fs (V, A)
4x4 digits backligh. LCD
(4x9 digits for energy).
10 times /s
±0.5% fs (V, A)
4x4 digits backligh. LCD
(4x9 digits for energy).
10 times /s
RS 485 port (on
request) [S1]
RS 232 port (on
request) [S]
Up to 2 single/dual
open collector or relay
modules
RS 485 port (on
request) [S1]
RS 232 port (on
request) [S]
Up to 2 single/dual
open collector or relay
modules
Up to 2 single/dual
open collector or relay
modules
Up to 3 (time per. mngt.)
RS 422/485 port
RS232 port + RTC
RS 422/485 port,
RS232 port + RTC +
2MB data or RS232 +
RTC
Up to 2 single/dual
open collector or relay
modules
Up to 2 single/dual
open collector or relay
modules
Up to 6 digital inputs
Input Specifications
Range Code
Accuracy
Display
Sampling Rate
Output Specifications
Serial communication
output
Alarm output
Pulse output
Digital input
Analogue output
Up to 3 (W/VAdmd sync.)
Up to 1 (mA/V)
analog. output module
Up to 2 single/dual
open collector or relay
modules
Up to 2 single/dual
open collector or relay
modules
Up to 3 digital inputs
Up to 2 single/dual
analog. output modules
General Specifications
Power supply
Approvals/Marks
24 VAC [A]
48 VAC [B]
115 VAC [C]
230 VAC [D]
18 to 60 VAC/DC [L]
90 to 260 VAC/DC [H]
CE
24 VAC [A]
48 VAC [B]
115 VAC [C]
230 VAC [D]
18 to 60 VAC/DC [L]
90 to 260 VAC/DC [H]
CE
18 to 60 VAC/DC
90 to 260 VAC/DC
18 to 60 VAC/DC
90 to 260 VAC/DC
CE - UL - CSA
CE - UL - CSA
See pag. 103
See pag. 103
See pag. 104
See pag. 104
Ordering References
90