UPNE-TECH SLAC-I 20A, 30A, 40A, 50A, 60A Solar charge controller User Manual

Below you will find brief information for Solar charge controller SLAC-I 20A, Solar charge controller SLAC-I 30A, Solar charge controller SLAC-I 40A, Solar charge controller SLAC-I 50A, Solar charge controller SLAC-I 60A. The SLAC-I is a solar charge controller that regulates the charging of batteries using solar panels. It features automatic voltage and current regulation, low voltage disconnect, temperature compensation, and multiple protection features. You can use it to power your house or other devices using solar energy.

PDF
Document
SLAC-I 20A, SLAC-I 30A, SLAC-I 40A, SLAC-I 50A, SLAC-I 60A Solar charge controller User Manual | Manualzz

Advertisement

Advertisement

Advertisement

Key features

  • Automatic voltage & current regulation
  • Low voltage disconnect
  • Temperature compensation
  • Multi-functional LCD display
  • Programmable battery type
  • Sophisticated programmable nightlight function
  • Built-in one year date logger
  • Voltage drop compensation
  • Complete electronic protection
  • 12V or 24V system voltage automatic recognition

Frequently asked questions

The SLAC-I controller is preset to operate with lead acid batteries with liquid electrolyte. You can adjust the controller to use VRLA batteries (GEL type) using Programming Menu 1.

The controller has 5 different modes to protect the battery from being deeply discharged. The controller is preset to Mode 1 from the factory. Use Programming Menu 2 to change the setting.

The controller has a sophisticated nightlight function that controls the load output at night. Two modes are available: Dusk to Dawn and Evening/Morning. The mode can be selected in Programming Menu 3.

The controller has complete electronic protection, including over temperature, over charge, over discharge, over current, short circuit, reverse polarity, and reverse charge.

The SLAC-I solar charge controller has a rated system voltage of 12V or 24V, rated system current of 20A/30A/40A/50A/60A, boost charge of 14.5V / 29V(25 °C) 2 h, equalization charge of 14.8V/29.6(25 °C) 2 h, float charge of 13.8V / 27.6V(25 °C), deep discharge protection, cut-off voltage of 11 – 12 V / 22 – 24 V depending on setting, reconnect level of 12.8V/25.6V, overvoltage protection of 15.5V/31.0 V, max charge current of 20A 30A 40A 50A 60A, max load current of 20A 30A 40A 50A 60A, self consumption of 4mA, max panel/battery voltage of 55V, temperature compensation of -4.5mV/cell*k, grounding of positive grounding, battery type of lead acid (GEL, AGM, flooded), dimensions of 140mm*96mm*40mm, max wire size of 16 mm², ambient temperature of -40°C-+60°C, IP grade of IP22, altitude of ≤4000m, and net weight of 356g.