STEAMCORE Spa II Steam Generator User Manual
Below you will find brief information for Steam Generator Spa II. The Steam Generator Spa II is a powerful and efficient device designed to generate steam for your steam room or shower. This unit is easy to install and use, and it comes with a variety of features to make your steam experience enjoyable and relaxing. The Steam Generator Spa II is designed to be used with copper or brass piping.
PDF
Download
Document
Advertisement
Advertisement
OPERATION & INSTALLATION MANUAL S T E A M G E N E R AT O R aobsessed with qualiy... TM aquality of life User Manual Manual Ä ¿  ¼ Users instruction----------------------------------------------------------------1 The steam equipment installation location----------------------------------- 1 The typical illustration of the steam equipment installation----------2 Installation of the steam line ---------------------------------------------- 3 Drawing of the steam generator----------------------------------------------5 Electrical requirements---------------------------------- ----------------------6 Power line assembly illustration----------------------------------------------7 Generators internal electrical wiring---------------------------------------8 Installation of the mood light--------------------------------------------------11 Choosing your models----------------------------------------------------------12 Steam generator structural drawing----------------------------------------13 Safety precautions of the controller----------------------------------------14 The safety and operating instruction of the controller-----------------14 Control panel (both SSI and SSII) dimensions----------------------------------15 Controller installation instructions ------------------ ---------------------16 Temperature sensor installation (only for SS I Control Panel) ----------17 Illustration for the controller panel (SS I Control Panel)-------------------------18 Operation instruction (SS I Control Panel)-----------------------------------------18 Illustration on the controller panel (SS II Control Panel)-------------------------20 Operation instructions (SS II Control Panel) ---------------------------------------20 Maintenance of the steam generator --------------------------------------22 Trouble shooting -----------------------------------------------------------------23 Specifications -------------------------------------------------------------------24 Prologue User Manual Certified to CAN/CSA Std. No. 88 Conforms to UL. Std. 499 Users instruction Ó Ã » § Caution: ¯ :æ ¾ ¸ Technical Hotline 905-951-6662 Ð ë Ö ª We are not responsible for the malfunction and damage from installation that does not comply to the user manual. Î ´ ° ´ ± ¾ Ê Ö ² á Ö ¸ Ò ý ° ² × ° Ê ¹ Ó Ã µ ¼ Ö Â µ Ä Ò â Í â £ ¬ ± ¾ ¹ « Ë ¾ ¸ 1.Make sure the model and the accessories are correct,including the voltage imput. 2.Make sure the steam power are matched with the steam room dimension. Pay much attention to the steam room's cubage and construction.If you have any problem,please refer to the Page 11 about the dimension selection. 3. Make sure to read this in manual detail. 4.We shall not be responsible for the product damage or malfunction caused by selfinstallation. 5.Steamcore Spa II series are packged in a box,please check the goods when it arrives to assure it is in good conditon, if you find any damage in the package,please contact the transportation company to file a claim for compensation. 6.This product must be used indoors. THIS UNIT MUST BE COMPLETELY INSTALLED WITH UNIONS TO ALLOW EASY REMOVAL IF FUTURE SERVICE IS NEEDED. It is strongly recommended that the water intake solenoid be connected to a water supply using a braided hose line. Teflon tape is required to make a liquid tight seal between the threads and a rubber gasket (washer) is used to seal Ø :ª the solenoid and the braided hose attachment. Incorporate thread sealant (teflon tape) on both the water intake Ò Öbetween and drain solenoid for a tight seal to avoid leaks. Choosing a right location Important: Install an exhaust fan outside of the steam room so it can expel the excessive steam from the shower room. Some locations recommended for installation. 1. The distance to the steam room less than 20ft, the standard cable which link the controller and the steam generator 22ft. 2. The steam generator should not be installed in the steamroom 3. Do n ot install outdoors or in any places that will influence the security of the machine by the environment. 4. Do not install a frigid loft or any place water will freeze. 5. Do not install it near burnable and combustible . objects or chemicals 6. Install in a dry place and make adequate ventilation. NOTE: Use teflon tape on the water intake solenoid and the drain solenoid to create a tight seal between the threads. Absolutely do NOT apply heat to the plastic solenoids (water intake & drain) during installation. Page 1 User Manual 7.Stable and horizontal.The steam generator has a hanging groove for mounting on the wall.Make sure the machine is steady and horizontally installed. 8.On both sides and the top of the steam generator needs at least 12 inches of clearance space. 9.The place where the machine is installed must be easily accesible and convenient for the disassembly of the machine. 10. The installation place must be convinent for the drain ofwater. 11. The steam pipe, safety valve, drain valve,water tube,steam outlet are still very hot after the steam generator has stopped working for some time. Keep the steam outlet away from the people. 12.The controller must be installed in the steam room,please refer to the instruction of the controller's installation and operation of the manual. ! The steam generator(including the controller) comply with CE , CSA and UL certificat ion standards. Attention: Installation drawing of the steam generator ! Attention: The drawing is only for sample. As for practical design of steam room, please consult with qualified designer, architect or builder. Supply Control panel Control Cable (20ft max) Pressure relief valve Steam outlet pipe Steam generator Water Inlet Pipe Water Drain Valve Steam Outlet Fill & Drain Solenoid Valves Page 2 User Manual Installation of pipeline ! Warning: The installation of all the pipes should be done by a qualified licensed plumber. 1. Use threaded unions when connecting pipes to fill/drain valves and steam line(s). 2. Use brass or copper only. 3. Do not use ABS, galvanized or PVC pipes. DO NOT HEAT AUTO FILL / DRAIN VALVES WITH TORCH DURING INSTALLATION. This will cause damage to the plastic solenoid valve which will cause malfuction or leakage. Water supply pipe (1/2'') 1. Connect hot water or cold water. Hot water with a temperature of not more than 160 . 2. Install shutoff valve in the water supply pipe. The shut off valve should be installed in a place where it is easily operated in emergency. 3. Clean the water supply pipe completely before connecting the water pipe to the steam generator. 4. It is suggested that a filter and anti-furring equipment be used in the water supply pipe. 5. The water pressure should be between 15 and 20 psi . If necessary, decrease the pressure accordingly. Excess pressure may cause leakage. The water flow rate should be aprox 8 gpm. . 6. If necessary, install equipment to prevent the water hammering sound, also install an approved backflow preventer as required by local codes. It is suggested that a thread on braided hose with a rubber washer be used for the water supply line in order to attach the shutoff valve to the water intake solenoid. Also use adequate teflon tape around the thread of the solenoids for a tight seal between the two fittings. Steam Pipe (Pipe Diameter: 3kW/4.5kW pipe size: 1/2'' 6kW & above: 3/4'') 1.Do not install any valves in the steam pipes. The steam can never be obstructed. 2.Install one or more steam lines equal to your steam generator steam outlet(s) and with the same same diameter size copper steam pipe between the steam outlet and the steam nozzle. 3.The heat insulation material used to insulate the steam pipe should be resistant to temperature as high as 250 or higher. 4.The horizontal part of the steam pipe should be installed inclining to the steam outlet or in the direction of steam generator. Do not bend it in a shape to make the cooled water stay in the curved pipe of the steam line. 5.The shorter the steam pipe, the better. Try to decrease the number of elbows and avoid abrupt turns. Do Not combine steam lines if generator has more than one steam outlet. Steam nozzle ! Attention: Ò â : ×Atte¢ntion: Õ ô ³ £ (3kW/4.5kW pipe size: 1/2'' 6kW & above: 3/4'') Do not install the steam pipe in an upper or lower direction repeatedly, this will affect the output of steam. Make sure for each steam outlet on the generator there is an individual steam pipe to the steam room with the same diameter size as the outlet. Å × ç ° ì Æ û Ê Ë Ó ¹ Õ Ã Since the steam nozzle and steam outlet are very hot, try to avoid installing Õ Ìô É Ì the steam nozzle in the position which will easily come into contact with a person Ó Ó É Ú Æ Å ûthe× çsteamº ìnozzle Õ Í inÆ ôthe³ ûposition ¿ ö 12 · Úinches ³ Ç È £ £ Èthe Ó ¬ ± ¦ Ifà Üthe steam ½ â «bath is Ö Â 1.Install above ground. µ ¥ install µ ½ Î Äthe Ö »steam£ Ãnozzle Ò ¬ Ã Ô Å â above ³ ç µ öthe Õ Ä Æ ô If· ûthe½ É £ ¦ µ ¬ ¼ in½ the Ó́ bathtub, 6 inches bathtub. steam room materials like acrylic or non-heat-resistant sheet, install additional heat insulators. 2.The steam outlet should be installed face down. Install the steam nozzle and tighten with hands (use silicone). Attention Ò :â: Æ Å û × ç ° ì × ² ½ £ ¦ µ ¬ ¼ Ö Ì Â É Ì Ê Ë Ó ¹ Õ Ã chemical solutions or harsh cleaning tools. ³ ½ £ Ó́ µ ¥ µ ½ Ä Î Ö » £ Ã Ò ¬ Ã Ô Å â ³ ç ö µ Õ Ä Æ ô · û ÕÉ ô In order do not or other ¢ to protect Ó Ó ÉtheÕ Ústeam Æ ônozzle, Å û × ç º ì useÕ Íwrench Æ ô ³ û ¿ ö tools · Ú Ç ³ È £ £ È Ó ¬ × Ücorrisve ½ â ¦ « to tighten, use a little soap water and soft sponge to wipe, and do not±useà Page 3 User Manual ! Important: 1.Please consult your distributors of building materials like acrylic, fiber glass or other anti-heat sheet about the installation position of steam nozzle. It is suggested that MS103412 anti-heat material can be used. 2.In the entire steam room, it is required that steam must not leak out. The pipes, its accessories and the holes in the wall should be airproof by applying silicone so that no steam will enter the holes in the wall. Aroma Essence Reservoir (apply a few drops) If non-heat-resistant material like acrylics is used as building material, reserve a gap no less than 1/4'' and fill with silcone. Silicone Use silicone to fill in the gaps in the wall to achieve the water proof and damp-proof effect. Inside wall of the steam room DO NOT REDUCE THE STEAM LINE PIPE DIAMETER. Drainpipe (1/2'') According to national or local codes, the steam generator drainage valve should be equipped with a drain pipe. The steam generator drains the water by using gravity. ! Attention: The drain pipe should not incline upwards so as to prevent the drainage of water. Steam generators 10.5 kw and up have an additional manual drain port right next to the auto drain port. This is only used for manual draining and should remain closed at all times. DO NOT HEAT AUTO FILL / DRAIN VALVES WITH TORCH DURING INSTALLATION. This will cause damage to the plastic solenoid valve which will cause malfuction or leakage. Safety Pressure valve(s) (Supplied only - must be installed on-site by plumber) 1.Pressure valve is a safety equipment in order to prevent too much steam pressure in the steam generator due to various reasons; such as, steam line blockage, undersized steam lines, steam line traps, vandalism, etc. 2. The Steam Safety Pressure Valve & Switch Application is Mandatory. A Pressure Safety Valve (Steam Pressure Valve) has been supplied with this steam generator unit. The steam generator has removable sealed plugs in place of the pressure valve mounting location (labelled). A qualified licensed plumber must install the supplied pressure valve during installation of the steam generator. Unscrew the plugs, and screw on the pressure relief safety valve supplied. Make sure hi-heat silicone is used to seal the safety valves to the boiler tank when attaching, allow silicone to cure 24 hours. The Pressure safety relief valve must be installed by a qualified licensed experienced plumber. Steam Generators 18 KW (18000 watts) and higher will have a factory installed Steam Pressure Switch. This switch will cut power to the steam generator when the inside of the boiler tank or steam line(s) pressure reaches over the manufacture's recommended limit. The switch will reset and activate power when the excessive pressure has been substantially reduced. This will re-occure until the cause of excessive pressure has been rectified. Page 4 User Manual Steam generator blue print. 395mm 304mm 130mm 35mm Steam outlet 260mm 230mm 25mm 98mm 160mm 148mm Water inlet 244mm 209mm Safety valve Water drainage Fuse for wire power supply Controller wire and light wire hole Power wire hole (metal conduit connector required) Fuse for wire power supply 465mm 383mm 156mm Steam outlet 307mm Water inlet 29mm 11 5 m m 213mm 190mm Safety valve Water drainage Fuse for wire power supply Controller wire and light wire hole Power wire hole (metal conduit connector required) Fuse for wire power supply Page 5 315mm 335mm 260mm User Manual 510mm 435mm 300mm 205mm Water inlet 28mm 265mm 215mm 142mm Safety valve 350mm 385mm 340mm Steam outlet Water drainage Fuse for wire power supply Controller wire and light wire hole Power wire hole (metal conduit connector required) ! Attention: ! Caution: Fuse for wire power supply to facilitate maintenance, keep the steam engine clean. If the information provided is limited, do not touch the pipeline and. electric equipment to avoid damage to the equipment, do not connect strong electric current directly to the components. Electrical requirements: Electricity supply: 1.Test the voltage of electricity supply and make sure steam generator with suitable electric voltage is used. and a 2.Insulated copper wire should be used with an anti-heat temperature of 90 specified voltage of 300V. Refer to national or local electricity consumption code for specifications. 3.Install an independent circuit breaker between the power supply and the steam generator so to provide an electricity supply with overflow protection and electricity leakage protection. ! Attention: All the connections must be in accordance with national and local electricity consumption code and be installed by professional licensed electricians. A suitable metal conduit and metal conduit connector should be used for the main power wiring connections. Page 6 User Manual Ampere Meter The total connected load should not be more then 80% of the rating of the overcurrent devices. Electricity supply Applicable space of the room (m3) Electric current (A) 3~6 4.5kW 240V~ 1PH 240V~ 1PH 4~7 12.5A 18.75A 6kW 240V~ 1PH 5~8 25A 7.5kW 240V~ 1PH 6~10 31.25A 240V~ 1PH 8~12 37.5A 208V~ 3PH 8~12 25A x 3 240V~ 1PH 10~13 43.75A 240V~ 1PH 12~15 208V~ 3PH 50A 33.3A x 3 Type 3kW 9kW 10.5kW 12kW 13.5kW 208V~ 3PH 12~15 14~18 15kW 208V~ 3PH 15~20 37.5A x 3 41.7A x 3 18kW 208V~ 3PH 18~22 50A x 3 The data provided above are for 240V(1PH) and 208V(3PH). Consult the manufacturer for three-phased electricity or electric voltage of other specifications. Within the steam generator, install an independent circuit breaker so as to provide an electricity supply with overflow protection and electricity leakage protection (ground fault interrupter.) Power Supply Wire Connection Power connection terminal L1 L2 L1 L2 L3 European Connection ( L2 = N "Neutral") L1 L2 (240V~ 1PH) ! ! Attention: L1 L2 L3 (208V~ 3PH) To avoid damage to the equipment, do not connect strong electric current to the component directly. Warning: This drawing is for explanation only. For actual installation, refer to national and local electricity consumption codes by professional licensed electricians. Page 7 Wiring Diagram 240V(1PH) Steamcore Spa ** Supply L2 L1 N L Water Level Sensor G To Control Panal Red(Short Pin) Black(Long Pin) Yellow(Middle Pin) Terminal Block Light J1-2 Red J1 Black Optional Brown Red Red auto reset hi-limit Red Red Blue Black Red Drain water valve Yellow S Red Red Fill water valve S Red J1-1 Black Yellow/Green Black Red manual reset hi-limit Black Red Steamcore Spa ** 3kW (240V - 1PH) Supply L2 L1 N L Water Level Sensor G To Control Panal Red(Short Pin) Black(Long Pin) Yellow(Middle Pin) Terminal Block J1-2 Red J1 Black manual reset hi-limit auto reset hi-limit Optional Brown Red Red Red Red Blue Light Black Red Drain water valve Yellow S Red Red Fill water valve S Red J1-1 Black Yellow/Green Black Red Black Red Steamcore Spa ** 4.5kW (240V - 1PH) Supply L2 L1 N L Blue Brown Red J1-2 Red Yellow/Green Black Black J2-2 Black J2-1 Black J1 J2 Black Black auto reset hi-limit Optional Red Red Red Red S Red Red Drain water valve Yellow S Red Red Fill water valve Black Red Light G To Control Panal Terminal Block Red(Short Pin) Black(Long Pin) Yellow(Middle Pin) Red J1-1 Red Water Level Sensor manual reset hi-limit Black Red Steamcore Spa ** 6kW / 7.5kW / 9kW (240V - 1PH) Page 8 European Connection ( L2 = N "Neutral") European Connection ( L2 = N "Neutral") Supply L2 L1 N L To Control Panal Blue Light Brown Optional Red Red Terminal Block Red J1-2 Red Red J3-2 Red Black J3-1 Black Black J2-1 Black Black J1-1 Black J2 J3 Black Black Red Red S Red Red Drain water valve Yellow S Red Red Fill water valve Black Red G Yellow/Green J1 Red(Short Pin) Black(Long Pin) Yellow(Middle Pin) Red J2-2 Red Water Level Sensor auto reset hi-limit manual reset hi-limit Black Steamcore Spa ** 10.5kW / 18kW (240V - 1PH) Red Wiring Diagram 208V (3PH) Steamcore Spa ** Supply Water Level Sensor L3 L2 L1 To Control Panal Red(Short Pin) Black(Long Pin) Yellow(Middle Pin) G J1 Terminal Block Yellow/Green J3-2 J2-1 J3-1 J1-2 J1-1 J2-2 J2 J3 Blue Red Optional Light manual reset hi-limit Black Red Brown auto reset hi-limit Red Red S Red Black Red Drain water valve Yellow S Red Red Fill water valve Black Red Black Red 12 psi pressure switch (UL - USA Application 18kw & Up) Steamcore Spa ** 15kW / 18kW (208V - 3PH) Supply L3 L2 L1 G Water Level Sensor To Control Panal Red(Short Pin) Black(Long Pin) Yellow(Middle Pin) Terminal Block Light Red J1-1 Red Red J1-2 Red J2 Black Black Optional Brown Red Red auto reset hi-limit Red Red Blue Red Red Drain water valve Yellow S Red Red Fill water valve S Red J2-1 Red J1 Yellow/Green Black Red manual reset hi-limit Black Red Steamcore Spa ** 9kW (208V - 3PH) Supply L3 L2 L1 G Water Level Sensor To Control Panal Light Brown Red J3-1 Red Red J2-1 Red Red J1-2 Red Red J1-1 Red Red J2-2 Red Red J3-2 Red J2 J3 Black Black auto reset hi-limit Optional Red Red Red Red Blue Yellow/Green Red Red Drain water valve Yellow S Red Red Fill water valve Black Red S Terminal Block J1 Red(Short Pin) Black(Long Pin) Yellow(Middle Pin) manual reset hi-limit Black Red Steamcore Spa ** 10.5kW / 12kW / 13.5kW (208V - 3PH) Page 10 European Connection ( L2 = N "Neutral") User Manual Sizing steam generator Measure the length, width and height (feet) of the current steam shower or bathtub area that has a ceramic wall finish. Example; L:7xW:5xH:8 = 280 Cubic Feet x 25% for Ceramic Wall Finish = 61.25 (61.25+280) = 341 Total. You would need a 9000 watt (9KW) steam generator. However, if your shower materials are; (is multiplied by:) Acrylic, cultured marble. 0.08 Ceramic Tile on Cement Board. 1.30 Ceramic Tile on Mortar Bed. 1.30 Glass or Glass Block 1.35 Porcelain tile on cement board 1.60 NATURAL STONE TILE (marble, granite, slate, travertine, etc) On Cement Board. 1.90 On Mortar Bed. 2.00 Natural Stone Slabs over 1/2" thick 2.25 Each Exterior Wall(s) Insulated 1.10 for each outside wall ! Important: The calculation formula for selecting the size of steam generator is for reference only. Due to the variability of the building, the specifications and size illustration are used as guidelines only. If we have complete information, including actual blueprint, project instruction and building details, we can select the type of generator. Page 11 User Manual Installation of the top light ! CAUTION: The rating of the light should not surpass 40W(rated power) to prevent damage to the transformer. The light should be installed on the top of the steam room or in a place which is not access ible to children. ! CAUTION: Take some moisture proof measures in the process of installation. Do not let the electrical components be exposed to moisture or, it will cause damage or short circuit. Light The steam control panel (Possible location) The steam outlet Under Sink (possible location) The steam generator ! CAUTION: The illustration is just for explaination,the practical installation must comply with the nation's electric criteria, and performed by a professional licensed electrician. Page 12 User Manual Configuration of steam generator 14 1 13 12 15 17 11 16 2 19 4 3 18 17 10 5 9 7 6 8 DO NOT HEAT DURING INSTALLATION. (heating with torch will cause damage to plastic solenoid valve) Subsidiary water tank 13 Fuse 1 Enclosure 7 2 Circuit board 8 Main water tank 14 Fuse 3 Steam Outlet 9 Heating Element 15 Ground wire connector 4 Pressure Safety Valve 10 Heat Hi-limit 16 Relay 5 Water fill valve 11 Transformer 17 Water level sensor 6 Water drain valve 12 Terminal block 18 Manual Reset Hi-Limit 19 Mood light transformer Use teflon tape and rubber gasket (washer) when attaching fittings to the water fill and drain valve to create a liquid tight seal. Page 13 User Manual Controller Maintenance 1.Use soft cloth with a little soap/water to clean the controller. 2.Do not use harsh cleaning tools. 3.If the controller is damaged, call a service electrician to replace it. Safety and operation information of the controller ! Warning: If the installation and operation instruction is not read or understood, do not install. In case there should be any dangerous installation and improper operation. Install the controller based on the installation instruction otherwise, the temperature in the steam room will be too high or not heated enough. If the controller is installed outside the steam room, the temperature sensor must be installed in the steam room. ! Caution: Do not install the controller wire in the same conduit with high voltage electric wire. Do not install close to hot water or .steam pipe ! Important: Before installing the controller, make sure the steam generator power is off otherwise the controller may be damaged. The instruction includes important safety, operation and maintenance information. Keep the instruction in the user's hands. If the steam generator is damaged or does not work normally, do not continue to install or use the controller. Turn main power supply off. Page 14 User Manual Control panel (both SSI and SSII) dimension SSI and SSII Control panel may be switched for Spa II 160mm 120mm 70mm 23mm SS I 113mm 75mm SS II Page 15 25mm User Manual Installation instruction of controller ! Important: Before installing the controller, make sure the steam generator is shut off otherwise the controller may be damaged. Step one Determine the installation location of the controller. The controller is designed to be installed in the steam room : 1. 4-5 feet from the ground. 2. Away from the steam nozzle and do not expose under the direct path of steam. 3. Installation on perpendicular wall. 4. The position of installation should facilitate easy operation and convenient wiring. The controller wire is 1.0 feet long with a controller lengthened wire of 20 feet long at the most. In the installation of controller, it should be in a position not more than 21 feet from the steam engine. If longer wire is needed, contact professional service personnel. ! Important: Do not install the controller under the water pipe or in a position where water comes into contact. Control Panel SS I Step two Drill a round hole of 35mm in diameter in a chosen position, no larger or smaller. Step three (1ft) Pull the controller wire through the round hole, connect it to the lengthened wire and then to the steam generator , and connect with the corresponding wire in generator . When the computer wire is plugged in, aim the the direction and insert horizontally, instead of shaking at left and right in case the computer needles could be damaged. Do the same when unplugging. Control Panel Extended wire (20ft) Important: Do not pull tight, or clip tight the controller wire in case of causing damage to it. Step four Start the power supply of steam engine, check and adjust connection, check each item on the page to make sure all functions work well. Page 16 Aor (1ft) ! ! Important: before repairing the controller, make sure the steam generator is shut off otherwise the controller may be damaged. SS II Steam Generator User Manual Step five Remove the paper on the b ackside . To achieve good sticking effect, keep the mounting surface clean and dry. Step six Locate the display screen in the direction of 12 o'clock, and press tight the controller to stick it to the wall. Control Panel SS I Control Panel SS II Control Panel SS I Control Panel SS II ! Important: To ensure horizontal installation of the controller, use a level if necessary. Temperature sensor installation(only for SS I Control Panel ) 1.The position of the temperature sensor should be within a range of 1.2-1.5M above the ground. Try to avoid installing near the steam nozzle or the opening side of the steam room door. 2.As shown in Fig.1, drill a small hole of 10mm in the selected position. 3.Apply a circle of silicone along the edge of the back of the sensor base (as shown in Fig.2). 4.Use a locknut to lock the sensor foundation. (As shown in Fig.2) 5.Let the temperature sensor go through the back of the sensor holder (As shown in Fig.3) 6.The temperature sensor should be installed by extending about 1cm from the front of the room to make sure the speed and accuracy of temperature control. 7.Apply silicone to the back and fix the sensor. (As shown in Fig.3) 1cm Temperature sensor 10 Temperature sensor base (optional) Locknut for temperature sensor base Drill Ground (Fig.1) (Fig.2) (Fig.3) Page 17 1.2~1.5m User Manual Illustration of the controller panel (SS I Control Panel) IN/OUT SHOWER USE 6 6 42 3 72 8 2 5 29 10 1 1 Power ON/OFF 6 LED SCREEN 2 Power Indicator LED 7 Steam Time Adjust Key--LOW 3 Steam Temperature Adjust Key--LOW 8 Steam Time Adjust Key--HIGH 4 Steam Temperature Adjust Key--HIGH 9 Mood Light Indicator LED 5 Steam ON/OFF 10 Mood Light ON/OFF Operation instruction (SS I Control Panel) Power ON/OFF When unit is powered on, power indicator LED should be lit. Press and release button to activate system and all function buttons. Meanwhile, power indicator LED goes out. Water input steam boil tank automatically, and LED screens display system, press . Shut down the button again. System drains out water in generator water tank automatically. (NOTE: If power indicator LED flashes when system is activated, it reports that generator water tank is lack of water. System shuts down power supply to heater elements, and opens water inlet valve to refill water until reaching required volume.) Page 18 User Manual Mood Light When system is activated, press and release button to turn on the mood light. Indicator LED on the right of the button should be lit. Press and release button again to shut down mood light. Steam ON/OFF When unit is powered on, press and release button, water input steam boil tank automatically, press and release button, steam starts emitting. Press button again to stop steam. Steam Time Setting Use and buttons to set desired steam time when system is activated. Steam time LED screen shows set time from 5 - 60 minutes. System shuts down power supply to heater elements automatically when desired steam time is over. Steam Temperature Setting Use and buttons to set desired steam temperature when system is activated. Steam temperature LED screen shows set steam temperature ranging from 5C - 45C or 50F - 110F. . When ambient temperature is higher than desired temperature, system shuts down powersupply to heater elements automatically. Meanwhile, temperature readings on LED screen flash until ambient temperature gets lower than set temperature. Do NOT set temperature setting more than 110F (45C). Select Temperature Unit When system has been turned off, press TEMP TIME and buttons at the same time, LED screen shows current temperature unit. Page 19 User Manual Illustration of the controller panel (SSII & SQII) Control Panel IN SHOWER USE ONLY 9 7 8 4 1 5 2 6 3 10 Power switch Time set button Time/temperature increase button Temperature set button Light function button Digital display screen The front decorative panel Operation instruction Time/temperature decrease button Steamcore Temperature sensor (SSII & SQII Control Panel) The controller is digital temperature control system which can start, stop or pause in the preset time to keep the temperature in the set number. ON/OFF When it is electrified, the system shuts off all the loads to remain in a waiting state, and the digital tube will display ---(as is shown in Fig.1). In the waiting state,press button to turn on the system and the steam function. The default time of starting the steam is 30 minutes and it begins to count down and the default temperature of the steam is 110F. After the system is started, the digital tube will display the current temperature of the environment and the temperature check range is 50F - 110F. Page 20 Fig.1 User Manual When the actual temperature is smaller than or equal to 32 F , the digital tube will display 32 F . When the actual temperature is smaller than or equal to 110 F , the digital tube will display 110 F . The last digit displays as the unit of Fahrenheit temperature. The default start time of steam function is 30 minutes. When the steam is starting, there is a shortage of water, the heating wire will stop heating and the water input valve will start automatically. If there is no water tested in 5 seconds or no water coming to reach the full volume in 15 seconds, the digital tube will flash to display (as shown in Fig.3) to hint mistake. If the water is full, the steam function will return to normal. When the steam function is started, if the temperature of the environment is higher than the set steam temperature, the heating wire will stop heating, the digital tube will flash to display the current environment temperature; when the environment temperature is lower than the set steam temperature, the heating wire will restore heating, the digital tube will display normally current environment temperature. When the system is started, press button or when the steam function time is due, the system will be shut. 10 minutes after the system is shut off, the drainage function will be started automatically for 5 minutes. Fig 2 Fig.3 Time setting When the machine is started, press button and the digital tube will display the remaining time of current steam function (as shown in Fig.4), press button or button to adjust the remaining time. The adjustment range is 5-60 minutes with minute as one level. If there is no adjustment in 5 seconds, the system will quit the time setting function. The digital tube will restore to display current environment temperature. Fig.4 Temperature setting Whenthemachine is started,press button and the digital tube will display the set steam time (as shown in Fig.5), at the same time the temperature unit will flash to hint that the machine has entered the steam temperature setting function. At this time, press button or button to adjust the temperature parameter. The adjustment range is 50-1 0 with 1 as one level. If there is no adjustment in 5 seconds, the system will quit the temperature setting function. The digital tube will restore to display current environment temperature. Do NOT set temperature setting more than 110F (45C) Page 21 Fig.5 User Manual Light function When the machine is started, press button repeatedly to turn on/off light function. When the light is turned on, the digital tube will temporarily display (as is shown in Fig.6). When the light is turned off, the digital tube will temporarily display ! (as is shown in Fig.7). Fig.6 CAUTION: 1.Please consult your physician before using.If you are pregnant,elderly,have high blood pressure,diabetes, suffering from heart disease, intoxicated,or not in good health, do not use this steam bath. 2.Children must be accompanied with adults when using this steam bath. 3.Steam is hot! Severe burn will occur if you come in contact with the steam head or steam emitting from the steam head. Fig.7 Maintenance of the steam generator ! Important: perform water discharge operation after each use. 1. Wait for the completion of automatic water discharge after each time of using the steam generator to make sure the water in the tank is discharged completely before cutting off power supply. 2. There should not be any leakage or damage among the steam generator , steam nozzle, components and pipes. They should be checked and repaired annually. 3. Clean the water supply pipes of the steam generator once a year. 4. Check all the connections, faucets and connection terminal to see whether they become loose or are damaged due to overheat. 5. Check the furring accumulated in the water tank and electric heating tube. If the furring is thick, dispose it in time (use diluted lemon acid to soak for 15-30 minutes). 6. Remove the water level sensor needle once every 3-4 months to clean scaling. Page 22 -OOD,IGHT#ONTROL ! # " ! 0OWERONOFF " # -ANUALCOLOURCHANGE !UTOMATICCOLOURCHANGE &UNCTION )NSTRUCTION !0USHBUTTONTOACTIVATEUNITSYSTEMRECALLSALLFUNCTIONS UNFINISHEDTHELASTTIMEUSEDANDPRESETsWORKINGTIMETO MINUTESBY DEFAULT0RESS"UTTONTOCHANGELIGHTCOLOURAUTOMATICALLY0USH ,IGHTCOLOURMANUALLY0USHAGAINTODEACTIVATE BUTTONTOCHANGE SYSTEM "#HANGECOLOURAUTOMATICALLY 7HENUNITISPOWEREDON0RESSBUTTONLightCHANGEsCOLOURAUTOMATICALLY ASPREPROGRAMMEDANDEACHCOLOURREMAINSFORSECONDS0USHBUTTON AGAINLAMPKEEPSPRESENTCOLOURPUSHBUTTONFORTHETHIRDTIMELAMP GOESBACKTOCHANGINGCOLOURAUTOMATICALLY ##HANGECOLOURMANUALLY %ACHTIMEBUTTONISPRESSEDLIGHTCHANGESONECOLOURINTHEFOLLOWINGORDER 7HITEREDPURPLEBLUEYELLOWGREENORANGE Page 23 -OOD,IGHT#ONTROL 4ECHNICAL$ATE 6OLTAGEINLET 6OLTAGEOUTLET /THERS 7ORKING#ONDITION !#6 2ATED&REQUENCY $#6 2ATEDCURRENT -AXINPUTVOLTAGE$#OFLAMP 6 MAX (: M! $#6 2EMARK )NPUTVOLTAGEISASSOCIATEDWITHTHESUPPLIEDTRANSFORMER)TCANBE6INLETVOLTS 5NITWOULDBEDAMAGEDIFTHEINPUTVOLTAGEEXCEEDTHE-AXLIMIT 0AGE User Manual Common trouble shooting methods To facilitate your use and maintenance of sauna room, the following common trouble shooting methods are listed for reference. Troubles Causes of troubles Trouble-shooting methods The machine does not start when electrified 1.The fuse is burned. 2.The wire connection terminal becomes loose. 3.Not good contact in the connection wire between the controller and the steam engine. 1.Change the fuse (on the shell 0.8A/ 250V) 2.Plug tight the wire connection terminal 3.Make sure the steam engine and the controller come into good contact Electricity leakage switch breaks automatically 1.The wire connector is dampened or damaged. 2.The heating tube breaks 1.Check whether the wire connector is dampened or damaged, and dry with dryer if dampened. 2.Change a heating tube. When the machine is started, hot water 1. The water drainage valve is broken. comes out with little or no steam 1. Change a water drainage valve. The display screen on the control panel does not display 1.The power wire is not connected well 1.Check whether the connection plug between or not in good contact. The connection the control panel and the electricallyplug between the control panel and the controlled box has become loose, and electrically-controlled box becomes whether the power circuitry has good contact. loose. 2.Change a plugboard. 2.Trouble with plugboard. Water leakage 1.The water pipe connector becomes loose or the pipe breaks 2.Water leakage in the water input valve or the waterdrainage valve 1.Tighten the loose connector, and change the broken pipe. 2.Change the water input valve or the water drainage valve. No steam when starting the machine 1.No electricity. 2.No water. 3.The set temperature is too low 4.Troublewithwire. 1.Check the power supply 2.Check the water input pipe and water input valve 3.Reset the temperature 4.Contact the distributor The steam does not come out, the water 1. The steam pipe is jammed. sounds in the machine 1. Cut power supply to check whether the steam pipe is smooth. The light can not be turned on 1. The fuse is burned. 2. The light is broken 3. The wire is broken 4. The plug does not have good contact 1.Change the fuse (on the shell 1A/250V) 2. Change a light bulb. 3. Change wire. 4. Make the contact good. The display box displays normally with no steam input 1.Too much pressure inside the steam engine, so the system breaks for heat protection. 2.Wire is broken for heat protection. 1.Check the steam transport pipe and restore automatically after heat protection becomes cool. 2.Check the heat protection wire to make sure the connection is good. Technical Hotline 905-951-6662 Page 25 User Manual ! Important: Consult a licensed electrician for service. Technical parameter TYPE Steamcore Spa II 240V 240V 240V 240V 240V 208V 240V 240V 208V 208V 208V 208V (1PH) (1PH) (1PH) (1PH) (3PH) (1PH) (1PH) (3PH) (3PH) (3PH) (3PH) (1PH) Current(A) 12.5A 18.75A 25A 31.25A 37.5A 25A x 3 43.75A 50A 33.3A x 337.5A x 341.7A x 3 50A x 3 12V/40W 12V/40W12V/40W12V/40W 12V/40W 12V/40W 12V/40W 12V/40W 12V/40W 12V/40W 50-10F 50-10F 50-10F 50-10F 50-10F 50-10F 50-10F 50-10F 50-10F ~ Min ~ Min ~ Min ~ Min ~ Min ~ Min ~ Min ~ Min ~ Min 50-10F ~ Min 0.12MPa 0.12MPa 0.13MPa 0.14MPa 0.14MPa 0.15MPa 0.16MPa 0.17MPa 0.18MPa 0.19MPa 140ml/Min 160ml/Min 180ml/Min 220ml/Min 260ml/Min 300ml/Min 360ml/Min 400ml/Min 450ml/Min 500ml/Min 100-150S 90-120S 100-160S 90-140S 80-130S 180-240S 150-160S 130-150S 120-150S 90-140S 8~12 10~13 12~15 14~18 3~6 4~7 5~8 6~10 15~20 18~22 ! Important: The parameter listed in the table will vary from different place and temperature,please consult with qualified designer and architect for more detailed use. Page 26 Steambath Generator Limited Warranty STEAMCORE Spa II Series Steambath Generator Limited Warranty Saunacore warrants these products to be free from defects in material and workmanship and agrees to remedy any such defect. This warranty does not apply outside the boundaries of the United States, Canada or any product which in our sole opinion has been improperly installed, or subject to willful abuse, misuse, alteration, and shipping damages during the period of coverage. Postage and handling charges of the product to and from Saunacore for warranty repairs and for any related charges for the installation / removal of these products are NOT included in your warranty. Warranty service can be obtained by sending your product to Saunacore (Call 905-951-6662). Warranty repairs must be done only by Saunacore. Proof of purchase and a serial number of the product will be required before any services are performed. Warranty applies only to the original consumer purchaser, warranty is non-transferable. For warranty repair, the steam generator must be returned to Saunacore with an Return materials Authorization # and is to be obtained by the original consumer purchaser and must be shown on all correspondence and packing, without this RMA # returns for repairs will NOT be accepted. Controls & Cables: One Year Parts and Labor Steam Generator Only: One Year Parts and Labor Second Year to Fifth Year Warranty Claim Fee (Admin/Deductible Fee) Applies $150.00 Steam Generator Components: Continuing after First Five Years of original consumer purchase date. Components Only Coverage Components Warranty (excluding auto drain, control, and cables) provided the original consumer purchaser agrees to pay all labor costs/fees incurred in connection with such repair. Warranty work will be performed when the steam generator is returned to a designated Saunacore location with a RMS number. WARRANTY does not cover damages caused by Calcium, Lime Stone build up or corrosion to the components to the steam generator. ______________________________________________________________ Warranty Registration Card Model # ____________________________________ Serial # __________________________________ Purchase Date ________________________________________________________________________________ Dealer Name and Adress ____________________________________________________________________________________________ Owner Name and Address ____________________________________________________________________________________________ NOTE: A COPY OF THE RECEIPT MUST ACCOMPANY THIS WARRANTY CARD. 27 ">

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Easy to install & use
- Produces quality steam
- Built-in safety features
- Variety of power options
- Digital control panel
- Mood light
Frequently asked questions
The size of the steam generator you need is determined by the size of the steam shower area and the materials used. The manual provides a formula to help you calculate the size you need, but it is best to consult with a qualified designer or architect.
The electrical requirements for the steam generator will vary depending on the model. The manual provides information on the voltage, current, and amperage required for each model. This information is also available on the product label.
You should use copper or brass pipes for the steam generator. Do not use ABS, galvanized or PVC pipes.
The manual recommends that you clean the water tank of the steam generator once a year. You can use diluted lemon acid to soak the tank for 15-30 minutes to remove any furring.
The steam generator comes with a one-year warranty on parts and labor.
The manual provides a list of safety precautions that you should take when using the steam generator. These include: consulting with a physician before using the steam generator, keeping children away from the steam generator, never touching the steam head or steam emitting from the steam head, and always turning off the power supply to the generator before performing any maintenance.
If you have a problem with your steam generator, you can refer to the troubleshooting section in the manual. If you can't fix the problem yourself, you can contact Saunacore for assistance.