Dacor Ett3652b Quick Specs
ETT304-1, ETT365-2, MET304 and METB365-1
Document # PG03-001
Revised 05/06/10 Page 1/3
30 Inch and 36 Inch Wide,
Millennia® Electric Cooktops
Product tolerances: ±1/16” (±1.6 mm) unless otherwise noted
21 1/4" *
(540 mm)
warning
4" (102 mm)
Chassis height
30 1/4" *
(768 mm)
•
Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
•
This appliance must be installed in accordance with the
accompanying installation instructions.
28 3/8"
(721 mm)
19 3/8"
(495 mm)
PLANNING
GUIDE
4" (102 mm)
Chassis height
36 1/4" *
(921 mm)
product dimensions - ETT304-1 AND MET304
(ETT304-1 shown)
34 3/8"
(873 mm)
19 3/8"
21 1/4" * (495 mm)
(540 mm)
Product dimensions - ETT365-2 AND METb365-1
(ETT365-2 shown)
* For units with stainless steel trim, other units may be up to 1/8" less.
Model No.
ETT304-1
Electrical Circuit Required
Total Connected
Load*
240 Vac, 60 Hz, 40 Amps.
6.9 kW (29 Amps.)
ETT365-2
240 Vac, 60 Hz, 40 Amps.
9.1 kW (38 Amps.)
MET304
240 Vac, 60 Hz, 40 Amps.
6.9 kW (29 Amps.)
METB365-1
240 Vac, 60 Hz, 50 Amps.*
9.6 kW (40 Amps.)
Minimum Supply Wire Size
Line and Ground Connections
No. 8 AWG
* For reference only, See the product data label on bottom of unit for exact specifications.
Electrical Supply Requirements
NOTES:
1.
2.
3.
The cooktop is supplied with a flexible, 48 inch long
power conduit consisting of two (2) insulated hot lead
conductors (L1 and L2) and one (1) insulated ground
conductor. There is no neutral connection. All leads are
copper. The conduit is connected to the right corner of
the cooktop. Do not connect the ground wire to neutral.
Tested in accordance with the latest edition of ANSI
Z21.1 and U.L. 858 Standard for household cooking
appliances.
These cooktops are not approved for recessed
installation.
Specifications subject to change without notice.
Install all appliances according to accompanying installation instructions.
www.Dacor.com
Phone: (800) 793-0093 3.1
ETT304-1, ETT365-2, MET304 and METB365-1
Document # PG03-001
Revised 05/06/10 Page 2/3
30 Inch and 36 Inch Wide,
Millennia® Electric Cooktops
PLANNING
GUIDE
All tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated
Allow a minimum of 6 inches (152 mm) clearance between
the top of the countertop and any combustible surface
below, including the upper edge of a drawer below the
cooktop. Proper under-cabinet clearance is also required
for the cooktop hold down brackets.
When installing model ETT365-2 or METB365-1 and the bottom of the chassis is
to be enclosed wall to wall, you must install Dacor ventilation duct kit ATD323.
Cooktop cutout in
top of cabinet
A
Model
7 3/4” X 4 3/8” ventilation cut-outs in enclosure floor
6” (152 mm)
Min. clearance
to combustible
surfaces
(A) Minimum Under Counter
Clearance (Width)
ETT304-1, MET304
30 1/2” (775 mm)
ETT365-2, METB365-1
36 1/2” (927 mm)
3/ ”
4
under counter clearance
3/ ”
4
1 1/2”
1 1/2”
top vieW VENTILATION cutoUT
Rear
wall
Model
6" (152 mm) Min.
from mounting surface to
combustibles below
cooktop chassis
(B) Minimum Under Counter
Clearance (Width)
ETT304-1, MET304
28 3/4” (730 mm)
ETT365-2, METB365-1
34 3/4” (883 mm)
B
19 3/4" Min.
2 1/4" Min. (502 mm)
(57 mm)
1" Min.
(25 mm)
6" (152 mm)
Min. to combustible,
side wall, both sides
Countertop cutout (without raised vent)
Specifications subject to change without notice.
Install all appliances according to accompanying installation instructions.
www.Dacor.com
Phone: (800) 793-0093 3.2
ETT304-1, ETT365-2, MET304 and METB365-1
Document # PG03-001
Revised 05/06/10 Page 3/3
30 Inch and 36 Inch Wide,
Millennia® Electric Cooktops
PLANNING
GUIDE
All tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated
3/8” Min. (10 mm)
flat countertop overhang
required behind cutout
Stiffener
5/8” Min. (16 mm)
flat countertop overhang
required behind cutout
Countertop
Stiffener
ETT or MET series cooktop
Countertop
ETT or MET series cooktop
Cabinet face
Cabinet face
3/8” Min. (10 mm) space
behind raised vent
chassis to clear stiffener
5/8” Min. (16 mm) space
behind raised vent
chassis to clear stiffener
ERV or PRV series raised
vent: Check raised vent
dimensions/specifications
to determine proper fit
RV series raised vent:
Check raised vent
dimensions/specifications
to determine proper fit
Floor
Floor
ERV and PRV series raised vent installation
side view
D
RV series raised vent installation
side view
E
B
Rear
wall
C
19 3/4"
(502 mm)
Cabinet
face
A
6" Min.
(152 mm)
1" Min.
(25 mm)
6" Min.
(152 mm)
countertop cutoUT (with raised vent)
top view
Model/Configuration
ETT304-1 or MET304 cooktop with ERV30
or PRV30 raised vent
ETT304-1 or MET304 cooktop with
RV30 raised vent
ETT365-2 or METB365-1 cooktop with
ERV36 or PRV36 raised vent
ETT365-2 or METB365-1 cooktop with
RV36 raised vent
6" (152 mm) Min.
from mounting surface to
combustibles below
cooktop chassis
countertop cutoUT (with raised vent)
ISO view
(A) Cooktop
Cutout Width
(B) Raised Vent
Cutout Width
28 3/4”
(730 mm)
27 3/4”
(705 mm)
34 3/4”
(883 mm)
33 3/4”
(857 mm)
Specifications subject to change without notice.
Install all appliances according to accompanying installation instructions.
(C) Total Cutout
Depth
(D) Raised Vent
Cutout Depth
(E) Minimum
Rear Countertop
Overhang
22 1/2”
(572 mm)
2 3/4”
(70 mm)
3/8”
(10 mm)
22 1/4”
(565 mm)
2 1/2”
(64 mm)
5/8”
(16 mm)
22 1/2”
(572 mm))
2 3/4”
(70 mm)
3/8”
(10 mm)
22 1/4”
(565 mm)
2 1/2”
(64 mm)
5/8”
(16 mm)
www.Dacor.com
Phone: (800) 793-0093 3.3
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement