9448
Installation and User Guide
Compatible Equipment
9040
660
Internal Sounder
Speech communicator
496327 Issue 1 1 of 6
9448
INTRODUCTION
The 9448 is a 3 zone control panel with separate Entry/Exit and PA zones, designed specifically for domestic installations. The control unit PCB is built into a polycarbonate box with keypad and eight indicator LEDs on the front of the lid.
Technical Specification
Dimensions
Weight
Power Supply
System Power Supply
Quiescent Panel Power
Standby Battery h x w x d 212 x 212 x 68mm.
Approx 1.1kg (without stand-by battery).
230VAC (Ambient Temp. 20 º C).
70mA nominal.
12 Volt, 2.1AH rechargeable lead-acid, Gel
Type battery.
Outputs
Bell, Strobe, and O/P are open collector transistor outputs.
Bell, Strobe
AUX (for detectors)
Communicator Outputs
Outputs
LS
500mA Max.
300mA, 12VDC.
PA, Intruder*.
PIR Set Latch/Shock Sensor Reset.
9040 (1 max).
Fuses
F1 - Battery
F2 - 12V AUX
2A Quick Blow.
1A Quick Blow.
Caution: When replacing fuses use the ratings quoted above.
* The control panel has none of the required software functions to allow it to conform with the required standards for remote signalling in the UK.
Scantronic recommend that you use this system for "bell only" installations.
Wiring
Figure 1 shows the layout of the 9448 PCB and its connector.
2 of 6 496327 Issue 1
9448 Programming
Figure 1. 9448 PCB Layout
Programming
Initial Start Up
Before applying power to the control panel, ensure that all zone circuits are connected (link out any circuits not used). DO NOT connect the 12V terminal to the external sounder or 12VAUX terminals to the detectors at this stage.
Caution: You may damage the panel if you connect bell and AUX power before you power up the system.
1.
Apply mains to the control panel.
The green power LED lights and the internal sounder will sound. Ignore any other lights.
2.
Key-in the factory default user access code: 1234.
The internal sounder stops. Ignore any other lights.
496327 Issue 1 3 of 6
Changing Default Programming 9448
3.
Key-in 0 then ENTER followed by the factory default engineer access code: 7890.
The Day LED goes off.
4.
Open the control panel lid.
You are now in programming mode.
Changing Default Programming
To change the factory defaults, the panel must be in programming mode.
Then:
1.
Key in a two digit programming command followed by "ENTER". (See
"Engineer Program Command List".)
2.
Key in the correct digit for the option you want, and then press ENTER.
The panel beeps twice to show that it has accepted the command.
The panel gives a single error tone if you enter an incorrect command
(or if you close the lid). Re-enter the correct command.
3.
Key in "99 ENTER" to leave programming mode when you have finished. You will then be in user mode.
Engineer Program Command List
To change:
Engineer Code
User Code 1
Zone 2 Entry
Route
Auto Re-Arm
Bell Duration
Entry time
Exit time
Key-in: Followed by: Notes
20 ENTER new code ENTER 4 digits
21 ENTER new code ENTER 4 digits (see note 1)
36 ENTER 0 ENTER
1 ENTER
Normal Alarm
Entry Route
40 ENTER 1 ENTER
4 ENTER
42 ENTER 1 ENTER
2 ENTER
3 ENTER
4 ENTER
43 ENTER 1 ENTER
2 ENTER
3 ENTER
4 ENTER
44 ENTER 1 ENTER
2 ENTER
3 ENTER
4 ENTER
Bell Trigger Type 50 ENTER 0 ENTER
1 ENTER
Never rearm
Rearm three times
90 seconds
3 minutes
10 minutes
20 minutes
20 seconds
1 minute
2 minutes
4 minutes
10 seconds
30 seconds
1 minute
2 minutes
SAB
SCB
Defaults
7890
1234 y y y y y y
4 of 6 496327 Issue 1
9448 Leaving Programming Mode
Prog O/P
Zone 1 in Part Set 52 ENTER 0 ENTER
1 ENTER
Walk Test
51 ENTER 0 ENTER
1 ENTER
PIR set latch
Shock reset
Normal Alarm
Entry/Exit
97 ENTER Trigger detectors. Press OMIT to exit test.
y y
Leave Program 99 ENTER (See note 2.)
Notes:
1. The end user may change the user codes (see separate user guide).
2. If the internal sounder activates when you use this command then check the lid tamper, bell tamper, and the global zone anti tamper.
Leaving Programming Mode
1.
Connect the battery.
2.
Complete the connections between the 12V terminal and the external sounder, and 12VAUX and the detectors.
Note: The SAB module in the external sounder will continue to ring until the hold off supply is connected, or until the bell cover lid tamper switch is closed.
3.
Close the panel lid.
4.
Key in "99 ENTER" to leave programming mode.
You are now in user mode.
To Re-enter Programming Mode
You can re-enter programming mode at any time when the panel is in the unset mode:
Key-in 0 then ENTER followed by the engineer access code.
Open the control panel lid.
You are now in programming mode.
Restoring Factory Defaults
The control panel can retain all programmed information and access codes if both mains and battery power fail. When power is restored the panel will simply need resetting with the customer or engineer's access code.
If the installer wants to return the panel to the factory default settings, then:
1.
Power down the control panel, mains and battery.
2.
Locate the pair of Molex pins marked 'RST' near the microcontroller.
3.
Place a small screwdriver blade to short between the 'RST' pins.
4.
With the blade still across the pins, apply battery power then mains.
The system loads the factory default user and engineer's access codes.
496327 Issue 1 5 of 6
Eningeer Walk Test 9448
5.
Remove the screwdriver blade.
6.
Key in 1234.
7.
Key in 0 then ENTER followed by 7890.
8.
You must now reprogram the system.
Engineer Walk Test
Allows the engineer to test all devices on the system.
1.
Enter programming mode.
2.
Key in "97 ENTER".
The panel gives a continuous tone.
3.
Open and close each detector contact in turn.
When a detector contact is open the panel gives an interrupted tone and flashes the zone LED.
4.
Press OMIT to stop the walk test.
Note that the Engineer's walk test allows you to test all zones including PA zones, zone tampers, and panel and bell tampers. The user's walk test does not allow this.
Set/Unset System
Omit zone/Part set
Test Bells
Walk Test
Change User code
User Commands
User code
2 + OMIT and/or 3 + OMIT + User code
4 + ENTER + User code
The system sounds the internal sounder for three seconds, followed by the bell and strobe for three seconds.
5 + ENTER User code
Key in User code to end test
6 + ENTER + current user code new user code + ENTER
6 of 6 496327 Issue 1