bPro Compact Scale Instruction manual

Add to my manuals
119 Pages

advertisement

bPro Compact Scale Instruction manual | Manualzz

bPro

Scale / Printer

Technical Manual

72186164

1

bPro – T2 bPro – C2 bPro – U2 bPro – U3/U4 bPro – R2 bPro – H2

©Mettler-Toledo, Inc. 2000

No part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, for any purpose without the express written permission of Mettler-Toledo, Inc.

U.S. Government Restricted Rights: This documentation is furnished with Restricted Rights.

2

INTRODUCTION

This publication is provided solely as a guide for individuals who have received Technical Training in servicing the METTLER TOLEDO product.

Information regarding METTLER TOLEDO Technical Training may be obtained by writing to:

METTLER TOLEDO

111 West Taihu Road, Xinbei District

Changzhou, Jiangsu, China

(+86) 519 8664-2040

FCC Notice

This device complies with Part 15 of the FCC Rules and the Radio Interference Requirements of the Canadian

Department of Communications. Operation is subject to the following conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to

Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

METTLER TOLEDO RESERVES THE RIGHT TO MAKE REFINEMENTS

OR CHANGES WITHOUT NOTICE.

3

4

PRECAUTIONS

READ this manual BEFORE operating or servicing this equipment.

FOLLOW these instructions carefully.

SAVE this manual for future reference.

DO NOT allow untrained personnel to operate, clean, inspect, maintain, service, or tamper with this equipment.

ALWAYS DISCONNECT this equipment from the power source before cleaning or performing maintenance.

CALL METTLER TOLEDO for parts, information, and service.

5

CONTENTS

1 Specifications....................................................................................................................................1

General Description .......................................................................................................................1

Features ........................................................................................................................................2

Customer/Vendor Display ...............................................................................................................3

Keyboard .......................................................................................................................................4

Dimensions ...................................................................................................................................7

Weighing Capacity .......................................................................................................................10

Tare ............................................................................................................................................11

Memory Specifications .................................................................................................................11

Agency Approvals.........................................................................................................................11

Electrical .....................................................................................................................................11

Label Printer................................................................................................................................12

Operating & Storage Temperature .................................................................................................14

Database Records ........................................................................................................................14

Major Compont Map.....................................................................................................................16

Index of Specifications .................................................................................................................17

2 Installation ......................................................................................................................................18

Unpack the Shipping Carton..........................................................................................................18

Setup Checklist............................................................................................................................19

Leveling ......................................................................................................................................20

Install Tower................................................................................................................................20

Install Platter...............................................................................................................................21

Power On.....................................................................................................................................21

Label Installation .........................................................................................................................22

Calibration ..................................................................................................................................23

3 Setup ..............................................................................................................................................26

Menu Tree for Scale Setup............................................................................................................26

Navigating within the Setup Menu......................................................................................................... 26

Menu Tree ........................................................................................................................................... 26

Enter setup ..................................................................................................................................29

Exiting setup................................................................................................................................29

Overview of mode functions..........................................................................................................30

SCALE CONFIGURATION................................................................................................................31

DATA ENTRY.................................................................................................................................32

Keyboard configuration.................................................................................................................48

Standard configuration ......................................................................................................................... 48

Function keys ....................................................................................................................................... 48

Special keys ........................................................................................................................................ 48

6

List CONFIG ......................................................................................................................................... 49

Operator configuration..................................................................................................................49

Standard configuration ......................................................................................................................... 49

New configuration ................................................................................................................................ 49

List Config ........................................................................................................................................... 49

Special function ...........................................................................................................................50

Label definition............................................................................................................................53

Password setting..........................................................................................................................53

Service function ...........................................................................................................................54

Function test ........................................................................................................................................ 55

Memory test......................................................................................................................................... 55

Interface test........................................................................................................................................ 55

High resolution display......................................................................................................................... 55

Primary configure................................................................................................................................. 56

Reset ticket number ............................................................................................................................. 56

Clear BRAM ......................................................................................................................................... 56

Fonts tabel........................................................................................................................................... 56

Reset scale as default .......................................................................................................................... 57

Clear all PLU data................................................................................................................................ 57

Clear Group ......................................................................................................................................... 57

Clear operator...................................................................................................................................... 57

Network configure ................................................................................................................................ 58

Ticket print test .................................................................................................................................... 59

Label Printer Test................................................................................................................................. 59

Configure RS232.................................................................................................................................. 60

Reports........................................................................................................................................61

PC software .................................................................................................................................64

Flashing Software ........................................................................................................................65

4 Troubleshooting ...............................................................................................................................66

Troubleshooting Guide..................................................................................................................66

POWER SUPPLY ...........................................................................................................................68

Main Logic PCB ...........................................................................................................................69

Load Cell.....................................................................................................................................71

Warning Message ........................................................................................................................71

Error Message .............................................................................................................................73

Interconnecting Diagram ..............................................................................................................75

5 Parts Replacement...........................................................................................................................76

Replace main PCB .......................................................................................................................76

Counter type ................................................................................................................................76

Hanging type: ..............................................................................................................................77

Replace switch power...................................................................................................................78

Counter type: ...............................................................................................................................78

7

Replace display ...........................................................................................................................80

Counter type ................................................................................................................................80

Hanging type: ..............................................................................................................................81

Replace load cell .........................................................................................................................82

Counter type ................................................................................................................................82

Hanging type: ..............................................................................................................................84

Replace keyboard.........................................................................................................................86

Counter type ................................................................................................................................86

Hanging type: ..............................................................................................................................87

Replace printer ............................................................................................................................88

Counter type ................................................................................................................................88

Hanging type: ..............................................................................................................................90

Replace printer head ....................................................................................................................91

Install Wireless card ....................................................................................................................92

Install the memory extension board ..............................................................................................95

6 Maintenance....................................................................................................................................97

External Cleaning ........................................................................................................................97

Cleaning Printhead ......................................................................................................................97

Rezeroing ....................................................................................................................................98

7 GEO Settings ...................................................................................................................................99

8 Replacement Parts.........................................................................................................................100

8

1

Specifications

General Description

The METTLER TOLEDO bPro is a digital computing scale with an integrated thermal label printer. It is an Ethernet scale with a wireless option, which has a database containing the PLU’s, Extra Text and etc. A PC program is available to download or upload the database from the PC. The bPro has 4

MB RAM memory and 4MB Flash ROM. The PLU memory can handle up to

25000 items.

The standard bPro weighing capacity is 15 Kg ( 30 Lbs). Weighting resolution can be set up for a single range with 0.005 Kg (0.01 Lbs) or a dual interval option for 0.002 Kg (0.005 Lbs) from 0 to 6 Kg (15 Lbs). In the dual interval, the single range resolution applies between 6 -15 Kg

(15-30 Lbs). Weighting options for 30 Kg (60 Lbs) are also available.

This scale utilizes a dot matrix display that will display weight, tare, unit price and total price, as well as item description.

The bPro, like all METTLER TOLEDO products is designed for maximum durability and reliability in even the most demanding application environments. The bPro is manufactured in one of METTLER TOLEDO's ISO

9001 and ISO 14001 certified facilities so you are assured to receive a high quality product.

1

2

Features

• 6kg, 15kg, 30kg (3000e or 3000e dual range)

• Full Dot Matrix display with 240x240 resolution on both operator side and customer's side.

• Four seven-segment numeric display for: 5 digits weight, 5 digits tare, 7 digits unit price and 7 digits total price. One 16-character alphanumeric display for programming and item description.

• Indicators for zero, net and prepack mode.

• Compliance with H44 3000e, R76 OIML 3000e and Canadian W&M.

• Light Touch Tactile feel membrane keyboard and an audible beeper.

• A 70 position preset keyboard for fast PLU retrieval. (can save 140 PLU in two levels) Includes QWERTY keypad in programming mode for easy PLU editing.

• Real time clock and RAM are backed up by a rechargable lithium battery with at least 1 month memory retention without external power.

• Push button zero (auto zero at power up) and automatic zero tracking.

• Price, Shelf Life, Quantity, and Extra Text, Label Format, and SPEC Message override capability.

• VOID key for clearing previous transaction from accumulator.

• Computer interface port (RS232), or Ethernet for use with BSOFT software.

USB port for PLU updates (Future)

• Integral thermal label printer with 8 dots/mm print head. Adjustable 40 to

60mm width. Supports both UPC and EAN symbology. The printer can use die cut labels, continuous strip labels and continuous thermal paper.

Customer/Vendor

Display

Indicates that a tare has been entered and the weight is NET.

There are two displays on the scale, one is on the vendor side and the other is on the customer side. They are all mounted on the tower except bPro-C2 model.

These two LCD displays incorporate a yellow color LED backlight. Both the customer and vendor displays show 5 digits of weight, 5 digits of tare, 7 digits of unit price and 7 digits of total price values along with cursors for Zero, Net and Prepack mode.

Both the customer and vendor displays can also show 16 alphanumeric characters for commodity description, marquee and prompt messages during programming.

The Weight display characters are 13.2mm high by 8.16mm wide. The Tare

Weight, Unit price and Total Price display characters are 11mm high by 6.6mm wide. The alphanumeric characters are 8.36mm high by 4.18mm. The display legends definitions are shown in the figure below.

Another 240x240 full dot matrix display, this can enable display Chinese, Thai language, Arabic etc, special offers to increase in-store scales.

Shows the normal weight.

The zero cursor indicates that the scale is within the zero range, either net or gross zero. If the display does not read 0.00 at ready, press the zero key.

Shows the Tare weight.

Shows Unit price.

Shows Total price.

Shows PLU description

3

4

Keyboard

The keyboard consists of membrane layer, rubber button layer, programming layer, operating layer and touch pad layer. The multi layer makes it easy to press the key which we call it light touch tech. The layers are replacable and you can take them down and wash them with water (except the membrane layer). This will make maintenance much easier.

The 28 keys on the right keypad are used for entering basic scale functions.

Operating Layer (T2 model)

Programming Layer (T2 model)

The keyboard can be adjusted to 4 levels according to customers’ wish. Only T2 and C2 models have this function.

Meaning of the function keys

Ä

Free entry of a price per piece

Ó

Continue

°

(PRINT,V2,V3,V4)Vendor, clerk

Ô

Go back

Ò

[TARE] Tare c

Clear;

0

Zero

Ç

Customer total , Confirm

[CODE] Code and switching

Æ

Manual entry of a price per piece to add v

Mode and switching

Å

Manual entry of a price per piece to subtract

»

Paper feed x

Multiplication

[FIX] Fixed unit price / fixed tare r

Change back

³

Void

Special functions o

Pressing CONFIG than PRINT will list the scale information on a label such as software version, IP address, MAC Address, scale type, scale ID, as well as the Product ID of the scale. o

Power On while pressing Print to access the Serial Flash mode for Wait for

Host o

Power On while pressing clear (C) to access the Network Flash mode o

Power On while pressing CODE to access display mode selection

Some type has the [TM] key, used to Tare manually.

Special functions keys

1 to 70

V2,V3,V4 preset keys vender keys V2-V4

[-%] increase/decrease key (Discount key)

Note: The left 70 keys are preset keys which can store 140 PLUs for fast

PLU retrieval. Different type has different quantity preset keys.

5

6

Remark :

*V2, V3 and V4 key can be configured as preset keys or vender keys, but one function is available at one time.

* [-%] key can be configured as preset key or increase/decrease key, but only one function is available at one time.

The following function keys can be used as word processing keys while entering

PLU description, store address, Extra Text and etc.

Meaning of the 'programming" keyboard keys h

Go to beginning of text e

Go to end of text

^ move the cursor one position left in the text edit mode

] move the cursor one position right in the text edit mode

Ó

Go to next sub-menu

Ô

Return to previous sub-menu s

Get upper case characters in text edit mode or select a key's 2nd function q

Alternate: special characters in text edit mode b

Backspace (delete the character left of the cursor)

[DELETE] Delete (delete the character on the cursor)

[iNSERT]

[ ABC ] Center the text in text edit mode

[ENTER] Carriage return (next line)

Ç

Selection of a menu

The 70 keys on the left keypad can be programmed as direct access keys (Presets).

There are two levels to the preset keys for a total of 140 PLU Presets. The Preset keys should be configured first before being used. Please refer to section 3 ‘PLU Preset’ for programming the Preset keys.

To recall a PLU simply select the proper level and press the desired preset.

Dimensions

bPro-T2 bPro-U2

7

8 bPro-C2 bPro-R2

bPro-H2

9

bPro-U3

Weighing Capacity

The bPro can be programmed for 3/6x0.001/0.002, 6/15x0.002/0.005kg,

15/30x0.005/0.010kg capacities. The built-in scale is designed to withstand static overloads up to five times the rated capacity without sustaining permanent damage.

A weight greater than five increments over capacity causes the weight display to

"-----" and printing is inhibited. If the scale is under zero by more than five increments, the weight field will display dashes "|_____|". When zero can not be captured, the weight field will display "-----".

10

Tare

Tare is limited to a maximum of 2/3 full capacity.

Memory Specifications

The Main Logic PCB contains a rechargable lithium battery that will retain backup

PLU's and the time/date in the SRAM memory for up to one month. Other data, including calibration data are retained in the EEPROM which requires no battery for memory retention.

Agency Approvals

The model bPro is designed to meet the requirements of the following agencies:

OIML R76 standard OIML

EC

NIST

Euro CE standard

NTEP requirements for Class III weight device.

NTEP/California Electronic Cash Registers General Code

Requirements

FCC Requirements for FCC Conducted Emissions and Radiated Emissions for a Class A device.

Electrical

The bPro requires a dedicated grounded 100/240 VAC, 50/60 HZ supply, and draws 0.3 amps (scale/printer versions). The AC line (including ground) must not be shared with noise and surge generating equipment such as, electric motors, compressors, thermostats, fluorescent lights, etc. A line conditioning device is

11

recommended to provide protection from surges and spikes. The Power supply uses an electronic overload protection circuit designed to protect the internal electrical components.

12

Label Printer

Labels can be printed with the built-in thermal label printer. The printer uses a

60mm wide, high resolution, 8 dots/mm, thermal print head. The printer driver PCB incorporates a heat detection circuit to ensure the best possible print quality while eliminating any possibility of overheating the head. Overheating is the major cause of premature print head failure. The print speed and density can be adjusted via

SERVICE MODE to compensate for varying types of labels.

The printer can use standard label sizes ranging from 25mm to 102mm long, and continuous strip stock. Labels can be loaded in a stripped or un-stripped mode. In stripped mode, the labels automatically peel from the backing liner. In the un-stripped mode, the label and liner will be delivered. A tear/bar allows continuous stock to be torn to exact length needed. Print specifications for the thermal printer are as follows:

PRINTHEAD TYPE:

DOT DENSITY:

PRINT SPEED:

Thick Film Thermal Printhead

8 Dots/mm

125 mm/sec maximum

Printer 2“ paper dimensions

A

B

C

A

Dimensions Labels

Min. Max.

A 30 mm 82 mm

D

B 130 mm

C 40 mm

D 30 mm 82 mm

E

F 25 mm 102 mm

G 56 mm eff. print width,

The print head is centred over

E the paper.

E

Print resolution: 8 Pixel/mm

F

Dimensions Receipt

F

G

A 52 mm

B 130 mm

C 11 mm

Paper length max: 150 m

13

Operating & Storage

Temperature

Operating Range:

Storage Range:

-10°C to 40°C (14°F to 104°F), humidity from 5% to

85% non-condensing.

0°C to 70°C (32°F to 158°F), humidity from 5% to 85% non-condensing.

Database Records

The PLU database file consists of:

Field Name Description

PLU Number Price Look Up number used for database indexing and to call up a record

Item Number

Description 1

Description 2

Range

0 – 999999

The product number is a number that is encoded in the EAN Bar Code symbol. This

0 – 9 each character number can be inputted up to 13 digits.

Text used to describe the product for line 1 28 char/line

Text used to describe the product for line 2 Up to 150 characters,10

Group No A two digit number between 0 and 99 used for reports; 0 is no group lines

0 – 99

Unit Price

2nd Unit Price

Price Rule No

Product unit price: Price per lb by weight or Price per piece

Second unit price. Depend on the price rule

Decide the Unit Price.

0,1: 1 st Unit Price 2: 2 nd Unit Price

3 -10: link to discount number

0.00 to

99999.99

0.00 to

99999.99

0 -10

Label Format This will contain the label format number.

0 = scale default. 101 through 109 are fixed formats. Others are custom label

0 – 199

2 nd Label Format formats.

Number for second label. 0 – 199

Best Before Days This is the number of days from the current 0 – 999

14

Sell By Days date that the item can be used

This is the number of days from the current date that the item can be sold

PLU Type By-Weight; By Count;

Tare/By Count No Tare number for by weight PLU;

Quantity for by count PLU

Fix Weight The Net Weight of By Count PLU

Extra Text

Number

This is the extra text number to be used with this PLU. ‘0’ means no ET will be added.

Increase/Decrease Allow PLU to have a discount

Allow Price

Change

This allows price changes during normal operation.

NUTRITION No. Number of Nutrition

Pack date print Print format for packing date

Best before print Print format for Best Before date

Sell by print

Graphic No.

Print format for Sell by date

Number of Graphic link to PLU

0 – 999

0/1

0 – 99/0-9999

0.00 – 99.999

0 – 999999

0/1

YES/NO

0-999999

0-4

0-5

0-5

0-200

15

Major Component Map

External Components

A

E

F

E

B

G

D

Ref Description

A Display

B Tower

D Printer

16

D

A

C

Index of Specifications

bPro - X X - X XX X- X 0X -X xxx

Type

T=Tower, C=Compact

U=Upper Keyboard

H=Hanging, R=Terminal

Style

3=Self service

Display

CAPACITY

B=Dot

Load Cell

Extension Memory

Extension

Network

PRINTER

Country finish code

17

18

2

Installation

Unpack the Shipping Carton

Open up the package box. Take out the platter ,attachments, then take out the scale.

Remove the foam inserts and plastic bag. Put the scale on the working counter and inspect for damage. Report any damage to the carrier promptly. DO NOT LIFT THE

SCALE USING THE SPIDER OR BACK DISPLAY. Verify you received the accessories listed below.

Tower bPro scale

Platter

Power cord

Operator manual

Security Seal and Quality Feedback card etc.

Note: If you choose to dispose of the package, please recycle the materials. The packaging is recyclable natural fiber with biodegradable adhesives.

Setup Checklist

Leveling

Install Tower

Install platter

Install label

Calibration

Reset RAM

Password keyboard

Operator Configuration

Label format

Barcode

Date/Time

Software

Ievel the unit using the feet for adjustment and bubble indicator as a guide.

Install Display Tower.

Put on the platter to scale.

Install labels in the printer.

New scales must be calibrated on site.

Initialize the scale and set all softswitches to factory default.

To configure the passwords of the specific menus.

To configure the function keys and directly access keys of the keyboard.

To configure printed media, individual label or ticket or total label.

To configure default label format.

To select bar code type.

To set up current date and time.

BSOFT program, which can be used to download or restore the PLU record, configuration, or other data.

19

Leveling

Adjust the four feet until the bubble, located under the scale platter, is in the center of the bubble level. Then adjust the foot locks until the feet are secure.

Bubble Level

Correct Incorrect

20

Install Tower

Tower Model

Take out the tower and insert it into the tower base. Connect the two flat cables together between the tower and the display base. Install four screws on both sides of the display base to lock the tower in place.

Upper Keyboard Model

Connect the two flat cables together between the tower and the display base.

Install four screws on both sides of the display base to lock the tower in place.

Install Platter

Power On

Take out the platter and put on to the scale.

Note: If unit has been stored or transported in below freezing temperatures, allow the unit to warm up to room temperature before turning on AC power.

Remove the power cord from the package box. Install the power cord in the recepticle on the bottom of the scale. Connect the power cord to AC power. Set the power switch to the ON position. Allow at least 30 minutes warm-up time before initial calibration.

21

22

Label Installation

Open the plastic door on the right side of the scale.

Slide out the printer.

Press the trigger to open the printer head.

Install the labels according to the instruction legend on the printer frame.

Pull out the take-up spool Insert the liner into the spool slot. Push back the spool.

Secure the liner on the take-up spool by spinning the spool clockwise.

Close the printer head gently, until it clicks.

Slide the printer into the scale. Close the plastic door.

Press the ` key to bring the label into the start position.

Note: Please refer to section 3 ‘Label Format’ to set the proper label format.

Calibration

Sealing Screw

Base

Calibration Switch

Cal Switch

Sealing screw

AD PCB

Steps :

1. Snip sealing wire

2. Screw out sealing screw

3. Operation: operation

" [CODE] 9*

"05*

"1

"*

SELECT THE FILTER

"*

"Push Calibration button

" (Input GEO value)

"* display comments

SERVICE FUNCTION Enter service mode menu

Select calibration sub-menu

DO NOT ENTER CAL 0-1

Enter calibration

QUIET

PUSH CAL BUTTON

SELECT GEO 12

0=QUIET;1=NORMAL;2=DISQUIET

Push the calibration button

23

"*

" (Input capacity)

"*

WEIGHT UNIT kg

CAPACITY 15

INC.0.002/0.005

Input capacity of scale

"Select interval with up arrow key [ ] Select interval of the scale

"*

"*

"Input the standard weight value you want to put on scale

"put on the standard weight on platter

"*

CAPTURE 0 ———

ADD WEIGHT 0.000

Read zero

Input the standard weight value you want to calibrate, at least 2/3 of capacity

DONE

SHUT DOWN

Power off scale and power on again

NOTE:

IN THE PROCESS IF GIVE THE MESSAGE “ INIT. CELL...”, WHICH INDICATE THE FAULTCALIBRATION.

24

26

3

Setup

Menu Tree for Scale Setup

Navigating within the Setup Menu

• 【ENTER】 Selects displayed item and moves to sub menu level, accepts the variable in the list.

• 【CODE】

• 【↑】

• 【↓】

• 【Clear】 a warning message

Backs up one menu level, does not accept change.

Moves Up to next menu item, will wrap around from the last entry to the first.

Moves Down to next menu item, will wrap around to end from the first entry.

Clears inputted Text for that field. Clear is also used to clear the PLU and clear

( Direct access numbers

Delete an entry

Code version

Kxxxxxx*xx

C

K* )

Menu Tree

To enter setup mode, press the [CODE] key

Press [CODE] key to return to the first option in the current menu. Press [CODE] key again to return to the previous menu. To exit out of SETUP mode, press [CODE] when the display shows normal weigh state.

DATA ENTRY

1

PRICE CHANGE

CREATE PLU

COPY PLU

EDIT EXTRA TEXT

LIST PLU

DELETE PLU

DEFINE PRESETS

LIST PRESETS

STANDARD PRESETS

DELETE PRESET

CREAT GROUP

LIST GROUP

DELETE GROUP

CREATE SP. OFFER

SP. OFFER BACKW.

DELETE SP. OFFER

LIST SP. OFFER

TARE

CREATE BARCODE

TICKET HEADER

TICKET BOTTOM

RUNNING MESSAGE

CREATE OPERATOR

LIST OPERATOR

DELETE OPERATOR

SHOP NAME

ADVERISEMENT

DATE TEXT

DATE / TIME

DISCOUNT

PACK DATE OFFSET

LOGO MESSAGE

STORE LOGO NUM

MENU END

111

112

114

115

106

107

108

109

110

101

102

103

116

126

127

140

141

142

143

144

145

146

147

148

149

148

128

129

130

132

135

136

138

139

210

211

212

213

214

215

216

218

219

201

202

203

204

205

206

207

208

REPORTS

2

RESET TO DEFAULT

SALES REPORT

PLU REPORT

PROMOTE RPT

GROUP REPORT

GROUP H REPORT

HOURLY REPORT

SETTLE REPORT

ST/VOID REPORT

VENDOR REPORT

CASHDRAWER

REPORT

WEEKLY REPORT

MONTHLY REPORT

YEARLY REPORT

COMBINE REPORT

CLEAR REPORTS

MENU END

501

502

503

504

401

402

403

404

301

302

KEYBOARD CONFIG

3

STANDARD CONFIG

FUNCTION KEYS

303 SPECIAL KEYS

304

305

LIST CONFIG

MENU END

OPERATOR CONFIG

4

STANDARD CONFIG

NEW CONFIG

LIST CONFIG

MENU END

SCALE CONFIG

5

STANDARD CONFIG

NEW CONFIG

LIST CONFIG

MENU END

630

631

632

633

634

635

624

625

626

627

628

629

636

637

639

640

641

642

619

620

621

622

623

643

CODE

601

602

SPECIAL FUNCTION

6

COUNTRY FINISH

ROUND PRICE

603 DISCOUNT ROUND

605

606

607

608

609

610

611

612

616

617

618

UNIT OF PRICE

UNIT PRICE PRINT

PRINT PRICE UNIT

WEIGHT UNIT PRINT

IF PRINT WGT. UNIT

PRINT WITH

MOTION

PRINT LESS 20E

AMOUNT 0 PRINT

PLU FORMAT SKIP

PLU INPUT TYPE

PLU NO. LENGTH

PLU NO. PREFIX

ET LINK TO PLU

PRICE OPEN TYPE

DISCOUNT TYPE

SPECIAL OFFER

OPEN PRICE MARK

OPEN PRICE MODE

UNIT OF BY-COUNT

FIX KEY

FIX KEY IN PREPACK

2ND LABEL PRINT

YEAR LENGTH

DATE FORMAT

DATE SEPERATOR

TIME FORMAT

MEMORY CHECK

SELL BY FORMAT

PACK DATE PRINT

WIRELESS OPTION

PLU DESC DISPLAY

PRECIOUS PRICE

IP LST BYTE MASK

SWITCH NET MODE

DISPLAY NEGA.

WEIGHT

701

702

703

704

705

706

707

708

801

802

803

804

805

806

807

LABEL CONFIG

7

SERVICE BY-WEIGHT

SERVICE BY-COUNT

PREPACK

BY-WEIGHT

PREPACK BY-COUNT

TOTAL LABEL

COPY LABEL

DELETE LABEL

MENU END

PASSWORD

8

STANDARD CONFIG

MANAGER

PASSWORD

SCALE PASSWORD

CODE PASSWORD

PRICE CHANGE PSW.

DISCOUNT PSW.

CLEAR PASSWORD

910

912

913

915

917

918

928

929

932

933

934

935

936

937

938

941

919

921

922

924

925

926

901

902

903

904

905

906

907

908

909

SERVICE MODE

9

FUNCTION TEST

MEMORY TEST

INTERFACE TEST

HIGH RESOLUTION

CALIBRATION

ERROR REPORT

APPLICATION

PRIMARY CONFIG

TICKET NO. TO 0

SET FILTER

CLEAR BRAM

FONTS TABLE

WORK CONFIG

DELET ALL PLU

DELETE ALL GROUP

DEL. ALL OPERATOR

NETWORK CONFIG

SOFTWARE LOAD

TICKET PRINTER

LABEL PRINTER

CONFIG INTERFACE

HEAD CLEAN ALERT

CHANGE PAPER MSG

COMM DEBUG

ASSERT DEBUG

CASHDRAW TEST

WIRELESS CONFIG

USB TEST

PRINT ALL TEXT

PRINT MENU LIST

CHECK FONT

27

644

646

648

649

650

651

652

CHANGE LANGUAGE

PLU NO. Length

EAN13 Style

PP PLU INPUT

CHAIN TARE

MARK DOWN

PLU DISPLAY FONT

28

Enter setup

To enter setup mode, press the [CODE] key.

Exiting setup

Mode functions

Press [CODE] key to return to the previous menu. To exit out of setup mode, press

[CODE] when the display shows normal weigh state.

Press

M

Call the menu "MODE CHANGE"

29

Overview of mode functions

M Call the menu "MODE CHANGE"

MODE CHANGE

_

00 SERVICE

_

01 VOID Operation

_

02 PREPACK

_

03 CODE-MODE

_

04 TRAINING-MODE

_

08 LARGE SALES

_

09 MENU END

With _ Q select the desired sub-menu, or enter the preset code.

Select/return to service mode.

Select/return to void operation mode.

Select/return to prepack mode.

Select/return to code mode.

Select/return to training mode.

Select/return to large sales mode.

Press _ to continue or

*

to return to weighing mode.

With _Q or the preset code, select the corresponding menu item, then activate it with the

*

key.

-For all weighing functions, registering, data entry and sales reporting

-Learning and practical exercises on the device, without the realized turnover being memorized.

-The "TRAINING"

-VOID OPERATION AFTER CHECK OUT means the ticket or label has been printout, and

these transactions will be deleted from the statistics data.

-For packing fieldwork of the supermarket. In this application, only print label, the small variety but large quantity print-work.

-When the article is too big to weigh, operator can enter this mode by inputting the article weight and count price.

30

SCALE CONFIGURATION

K5* Call the menu "Scale configure", this menu for distributing the memory of scale.

new configuration:

SCALE CONFIG.

_

02 NEW CONFIG.

*

RAM FOR PICTURE

_

plu description 2

_

number of plu

_

NF numbers

_ extra text size

_ extra text

_

config. no

MODE CHANGE

_

01 STANDARD CONFIG.

_

02 NEW CONFIG.

_

03 LIST CONFIG

_

04 MENU END

200

28

12000

100

200

1000

0-1

Enter preset code 02

Enter the RAM size for the pictures includes STORE LOGO, PLU

Graphics, SafeHandling, Screen Saver. Range 0-500.

Enter the quantity of PLU DESCRIPTION 2 characters. Range

0-150.

Enter the quantity of PLU in the scale. Range 50-25000.

Enter the Nutritional facts quantity. Range 0-100.

Enter the max. extra text size of each one.

Range 0-500.

Enter the extra test quantity for the scale. Range 0-20000.

(Actual number depends on previous setting, use the rest memory after previous data). whether to save the change 0=no;1=yes

Will show the actual number for PLU QTY, ET size and QTY.

31

DATA ENTRY

K1*

Call the "DATA ENTRY" menu

DATA ENTRY

01 price change

02 create plu

06 edit extra text

07 list plu

08 delete plu

09 Define presets

10 list presets

11 standard preset

12 delete preset

14 create group

15 list group

16 delete group

26 create sp. offer

27 sp. offer backw.

28 delete sp. offer

29 list sp. offer

32

30 tare

32 create barcode

35 ticket header

36 ticket bottom

38 running message

39 create operator

40 list operator

41 delete operator

42 shop name

43 advertisement

44 date text

45 date / time

46 discount

47 pack date offset

48 logo message

49 store logo number

50 menu end

Select desired menu with _Q

or enter preset code and activate with

*

key.

33

price change:

DATA ENTRY

_ enter the preset code 01

01 PRICE CHANGE

* plu number or preset

*

0 enter the PLU number or press the preset key to choose PLU

UNITPRICE

*

0.00

enter new price create plu:(each item can be chosen in menu "code-6-16(plu format skip)"

DATA ENTRY

_

02 create plu

*

plu Number

_

art. Nr.

_

ENTER TEXT

*

0

0

-

ENTER TEXT 2

*

GROUP NO.

_

UNIT PRICE

_

SECOND PRICE

_ price rule no.

_ label no.

_

second label no.

_

TARE NUMBER/QTY PER ITEM

_

-

0

0.00

0.00

0

0

0

0

Press the _

key twice or enter the preset code 02.

Enter the PLU number.(1~999999)

Enter the article number (up to 13 figures).

Enter the commodity text (up to 28 characters)

Enter the 2nd commodity text (up to 150 characters, see

SCALE CONFIGURATION, 10 lines as use _ key to change )

Enter the article group number. (1~99)

Enter the unit price. (0~9999.99)

Enter the second price if necessary. select which unit price as calling out PLU. 0,1: 1 st Unit Price 2:

2 nd Unit Price;3 -10: link to discount number

Input the label number (0-108, 101~108 are fixed label formats)

Input the second label number if necessary.

Tare number for by weight PLU 0=no tare, 1~16=tare number

Quantity for by count PLU 0-9999

34

best bef.offset

_

sell by offset

_ by weight

_

fix weight

_

EXTRA TEXT NUMBER

_ no in/decrease

_ open price yes

_

NUTRITION NO.

_

PRINT PACK DATE

_

SELL BY PRINT

_

BESTBEFORE PRINT

_ copy PLU:

DATA ENTRY

_

03 COPY plu

*

plu Number old

_

plu Number new

_

K

K

0.00 0.00 0.00

0

0

0

0

0

0-1

0

0

0-1

0-2

0-2

0

0

Enter the best before offset(0~999)

Enter the sell by offset(0~999)

Is it an article per piece or a weighed article ?

0 = weighed article,1 = article per piece

Enter the FIX WEIGHT for article per piece

Enter the Extra text number

0=don't allow in./decrease

1=allow in./decrease

0=price can't be changed

1=price can be changed by # key

Enter the nutrition number if print the pack date,0- 4

Not print/yymmdd/mmdd/mmddyy/ddmmyy

SELL BY DATE format,0-5

Not print/yymmdd/mmdd/mmddyy/ddmmyy/days

BEST BEFORE DATE format,0-5

Not print/yymmdd/mmdd/mmddyy/ddmmyy/days enter preset code 03 enter PLU number enter PLU number copy next plu, return to weighing mode

35

Edit Extra text:

DATA ENTRY

_

06 edit extra text

* extra text number

_ enter text

_

K

K

0.00 0.00 0.00 list PLU:

DATA ENTRY

_

07 LIST plu

*

FROM PLU NUMBER

_

TO plu Number

_

K

0.00 0.00 0.00 delete PLU:

DATA ENTRY

_

08 delete plu

*

PLU NUMBER

_

DELETE NO

_

K K

0.00 0.00 0.00

0

-

0

0

0

0-1

36 enter preset code 06 enter extra text number enter the Extra text (use the

*

you can change line) return to weighing mode enter preset code 07 enter PLU number(0=all PLU) enter PLU number(0=all PLU) enter preset code 08 enter PLU number

0=not delete;1=delete clear next PLU return to weighing mode

define preset keys:

DATA ENTRY

_

09 DEFINe presets

* l1 PLU KEY

PLU NUMBER

_

K

K

0.00 0.00 0.00 list preset keys:

DATA ENTRY

_

10 LIST presets

*

K

0.00 0.00 0.00 standard preset key:

DATA ENTRY

_

11 STANDARD preset

*

ALLOCATION NO

_

K

0.00 0.00 0.00

FXX

0

0-1 enter preset code 09 press a preset key(you can choose the layer L1 or L2 by press the key Q )L1=level 1 ;L2=level 2 enter the PLU number define next preset key return to weighing mode enter preset code 10 print the list enter the preset code 11

0=not allocate,1=automatic allocation by the system(plu

1-F001)

37

delete preset key:

DATA ENTRY

_

12 delete preset

*

DELETE NO

_

K

0.00 0.00 0.00 create article group:

0-1 enter the preset code 12

0=not delete,1=all preset keys are cleared return to weighing mode

DATA ENTRY

_ enter preset code 14

14 create Article Group

*

ARTICLE group

ENTER TEXT

0 enter group number

_ enter group name(18 characters)

___ list article group:

_

0

Input the TAX of this group

VAT ?

_ difine next group

K K return to weighing mode

0.00 0.00 0.00

DATA ENTRY

_

15 list Article Group

*

FROM GROUP

_

TO GROUP

_

K

0.00 0.00 0.00

0

0 enter preset code 15 enter group number (0=all group) enter group number (0=all group) printing the list of group return to weighing mode

38

delete article group:

DATA ENTRY

_

16 delete Article Group

* group NUMBER

_

0

DELETE NO

_

0-1

K

K

0.00 0.00 0.00 create special offer:

DATA ENTRY

_

26 create sp.offer

*

ENTER TEXT

___ from

_

00-00 to ?

_

00-00

Plu number

_

0 special offer

_

K

K

0.00

0.00 0.00 0.00 enter preset code 16 enter group number

0=not delete;1=delete delete the next group retun to weighing mode enter preset code 26 enter the detail of special text enter the start time for all special offer enter the end time for all special offer enter PLU number enter the special offer PRICE return to weighing mode

39

forbid special offer:

DATA ENTRY

_

27 sp. offer backw.

* plu number

_ back NO

_

K

K

0.00 0.00 0.00 delete special offer:

DATA ENTRY

_

28 delete sp. offer

* delete no

_

K

0.00 0.00 0.00 list special offer:

DATA ENTRY

_

29 LIST SP. OFFEr

*

KK

0.00 0.00 0.00

0

0-1

0-1

40 enter preset code 27 enter PLU number

0=No prohibition, 1=Prohibit SP. OFFER for this PLU retun to weighing mode enter preset code 28 delete the special offer

0=not;1=yes return to weighing mode enter preset code 29

Print the special offer list return to weighing mode

Tara weight:

DATA ENTRY

30

_

TARE

*

TARE NUMBER

_

TARE

_

CODE

CODE

0.00 0.00 0.00

0

0.000

Enter the preset code 30

Enter the tare number (1-16).

Enter the tare weight in grams *) or put the empty recipient on the scale, then validate with the tare key T .

Press _ to affect the next tare memory.

Press the K key twice to return to the weighing mode.

*) Respect the increment (1 g, 2 g or 5 g, depending on the weighing range) create EAN code:

DATA ENTRY

_

32 create ean code

*

EAN CODE NUMBER

_

EAN 13

_

*

art.number shift

_

total price shift

_ quantity shift

_ unit price shift

_

0-1

0-6

0-8

0-2

0-3

0-2 enter preset code 32 enter EAN code number(1-8):1=for ticket and 2-8 for label select barcode type,0=EAN 8;1=EAN 13;2=ITF 25 NARROW;3=ITF

25 WIDE;4=EAN128;5=EAN 13+5;6=UPC-A

Select check sum type,0=normal;1=reverse;2=no check sum select Article number shift in barcode. select total price shift in barcode. select quantity shift in barcode. select unit price shift in barcode. select weight shift in barcode.

As you use EAN 13 code format,max.13 figures,13th figure=check digit, you must enter 12 figures. 41

(As youuse EAN 25 code format,max.18 figures,18th figure=check digit, you must enter 17 figures.

WEIGHT SHIFT

_

EAN CODE

_

KK

0-2

-------

0.00 0.00 0.00

LEGEND OF EAN INDENTIFICATION

A=article number

C=checkdigit

D=date

P=PLU code

W=group number

B=amout

Q=quantity

0-9 Figures

Example:

Figures 1-6: 0-9,W,P

Figures 7+8: C

Figures 8-12: B,Q,0-9

Figures 13: C up to 13 figures

1 figure

6 figures

6 figures

2 figures

5/6 figures

4/5 figures

12 figures

=Possible entry

=Possible entry

=Possible entry

=Possible entry

Examples:

0AAAAAAAAAA (UPC, Ten digit Item Number)

2AAAAACBBBB (UPC, 5-D Item/Price Check Digit/4-D Price)

2AAAAA0BBBB (UPC, 5-D Item/Zero Fixed/4-D Price)

2AAAAABBBBB (UPC, 5-D Item/No Price Check/5-D Price)

2AAAAACQQQQ (UPC, 5-D Item/Wgt Check Digit/4-D Wgt)

2AAAAAAQQQQ (UPC, 6-D Item/No Price Check/4-D Wgt)

2AAAAAQQQQQ (UPC, 5-D Item/No Price Check/5-D Wgt)

21AAAAABBBBB(EAN,5-D Item/5-D Price)

21AAAABBBBBB(EAN, 4-D Item/6-D Price)

21AAAAACBBBB(EAN,5-D Item/Price Check Digit/4-D Price)

21AAAACBBBBB(EAN,4-D Item/Price Check Digit/5-D Price)

21AAAAAQQQQQ(EAN,5-D Item/5-D Wgt)

21AAAACQQQQQ(EAN,4-D Item/Wgt Check Digit/5-D Wgt)

42

define ticket header:

DATA ENTRY

_

35 ticket header

*

ENTER TEXT

___

*

K

0.00 0.00 0.00 define ticket bottom:

DATA ENTRY

_

36 ticket bottom

*

ENTER TEXT

___

*

K

0.00 0.00 0.00 define runing display message:

DATA ENTRY

_

38 running message

*

ENTER TEXT

___

*

K

0.00 0.00 0.00 enter preset code 35 enter text(Max.4 lines;100 characters) return to weighing mode enter preset code 36 enter text(Max.4 lines;100 characters) return to weighing mode enter preset code 38 enter text(Max.100 characters) return to weighing mode

43

create operator:

DATA ENTRY

_

39 create operator

* operator NUMBER

_

ENTER TEXT

___

_

0

_

_

K K

0.00 0.00 0.00 operator status:

DATA ENTRY

_

48 list operator

*

K

0.00 0.00 0.00 delete operator:

DATA ENTRY

_

41 delete operator

* operator NUMBER

_

DELETE NO

_

KK

0.00 0.00 0.00

0

0-1

44 enter preset code 39 enter operator number(1-5) enter operator name(18 characters) enter password of this operator if necessory confirm password define next vendor return to weighing mode enter preset code 40 print the list enter preset code 41 enter operator number(1-5)

0=nor delete;1=delete delete next operator return to weighing mode

difine shop name:

DATA ENTRY

_

42 shop name

*

ENTER TEXT

___

*

K

0.00 0.00 0.00 define advertisement text:

DATA ENTRY

_

43 advertisement text

*

ARTICLE group

_

ENTER TEXT

___

*

KK

0.00 0.00 0.00 define date text :

DATA ENTRY

_

44 date text

* date text NUMBER

_

ENTER TEXT

___

*

K K

0.00 0.00 0.00

0

1-3 enter preset code 42 enter text(4 lines,100 characters) return to weighing mode enter preset code 43

1-10 advertise text number enter text(1 lines,60 characters) return to weighing mode enter preset code 44

0=none ;1-3 date entry enter text(18 characters) return to weighing mode

45

define date/time:

DATA ENTRY

_

45 DATE / time

* date

_ time

_

KK

0.00 0.00 0.00 define increase/decrease:

DATA ENTRY

_

46 discount

* discount nr.

_ discount name

___

* discount text

___

0

0-1

0

46 enter preset code 45 enter date (the format in [setup]-6-31 menu) enter time in format:HH-MM-SS (the format in [setup]-6-33 menu) return to weighing mode enter preset code 46 enter increase/decrease number(1-16) enter increase/decrease name enter increase/decrease text enter increase/decrease rate return to weighing mode

* percent xx%

_

K K

0.00 0.00 0.00 define pack date offset:

DATA ENTRY

_

47 pack date offset

_

K

0.00 0.00 0.00 define LOGO message:

DATA ENTRY

_

48 LOGO Message

_

K

0.00 0.00 0.00 define store LOGO:

DATA ENTRY

_

0

0

0 49 LOGO Message

_

K

0.00 0.00 0.00

0 enter preset code 47 input the pack date offset number. return to weighing mode enter preset code 48 input the message showed after “SYSTEM LOADING”, up to 16 characters. return to weighing mode enter preset code 49 enter store logo number(0-255) return to weighing mode

47

Keyboard configuration

Enter the menu【CODE】【3】【*】,display will show “KEYBOARD CONFIG”, then do following operation.

Standard configuration

【 01】【*】 display “CONFIG. NO” press key: 0=NO,1=YES,then press【CODE】 key, and press 【CODE】 key exit SETUP mode.

Function keys

【 02】【*】 display “KEY ST ON 0-1”

to active key “ST”, 0=OFF (disable), 1=ON (enable), press 【*】 key, display next option “KEY R ON 0-1”;

to active key “R”, 0=OFF (disable), 1=ON (enable), press 【*】 key, display next option “KEY X ON 0-1”;

to active key “X”, 0=OFF (disable), 1=ON (enable), press 【*】 key, display next option “KEY - ON 0-1”;

to active key “-”, 0=OFF (disable), 1=ON (enable), press 【*】 key, display next option “KEY + ON 0-1”;

to active key “+”, 0=OFF (disable), 1=ON (enable), press 【*】 key, display next option “KEY # ON 0-1”;

to active key “#”, 0=OFF (disable), 1=ON (enable), press 【*】 key, display next option “KEY TARE ON 0-1”;

to active key “TARE”, 0=OFF (disable), 1=ON (enable), press 【*】 key, display next option “KEY FIX ON 0-1”;

to active key “FIX”, 0=OFF (disable), 1=ON (enable), press 【*】 key, then press key 【CODE】to exit the setting mode.

Special keys

【 03】【*】 display “OPERATOR KEYS 1” input the quantity of operator, then press key 【*】, display “NO IN/DECREASE 0-1”; to select if use the DISCOUNT key, press key 0=NO (disable),1=YES (enable),as select

“NO”, press key【*】, display “CONFIG NO 0-1”, then press 0(not save)/1(save), press key 【*】to finish. As select “YES” to enable the DISCOUNT key, display “DISCOUNT

NO.”, then show “CONFIG NO 0-1”,press key 0(not save)/1(save), press key 【*】 to finish. press key 【CODE】 to exit SETUP mode.

48

List CONFIG

Print out current keyboard config.

Operator configuration

Enter the menu【CODE】 【 *】,display will show “OPERATOR CONFIG”, then do following operation.

Standard configuration

【 01】【*】 display “CONFIG. NO”

press key 0=NO,1=YES,then press key 【*】. Press 【CODE】 to exit SETUP mode.

New configuration

【 02】【*】 display “SERVICE MODE 0-1” select the mode as power on: 0=SERVICE MODE, 1=PERPACK MODE, press key 【*】, then display next option “DATE & TIME 0-2”;

select print paper, 0=TICKET, 1=LABEL, 2=LABEL+TOTAL LABEL , 3=TOTAL LABEL , press key 【*】 , then display next option “DATE+TIME 0-2”; select display contents as idle, 0=RUNNING MESSAGE , 1=DATE+TIME , 2=BOTH OFF , then press key 【*】, display next option “SCREEN SAVER 0-5”; select the idle time before displaying screen saver pictures: 0=NO SCREEN SAVERS, 1=

TWO MINUTES, 2=THREE MINUTES, 3=FOUR MINUTES, 4=FIVE MINUTES, 5=SIX

MINUTES, press key 【*】, then display next option “ONE SECOND 0-5”; select the interval of screen saver pictures: 0=ONE SECOND, 1=TWO SECONDS,

2=THREE SECONDS, 3=FOUR SECONDS, 4=FIVE SECONDS, 5=SIX SECONDS, press key

【 *】, then display next option “TARE DISPLAY 0-1”; select if show and print tare, 0=TARE DISPLAY , 1=NO TARE , then press key 【*】, display next option “PR. INPUT W/# 0-1”; select inputting temporary price method with # key, 0=PR. INPUT W/# , 1=PR.INPUT

W/O # , then press key 【*】. Press key 【CODE】 to exit SETUP mode.

List Config

Print out the OPERATOR CONFIG

49

Special function

NO. NAME

01

05

06

07

08

09

10

11

12

16

17

18

Country Finish

Unit of price

Unit price print

Print less 20e

Amount 0 Print

Plu format skip

Plu input type

Enter the menu【CODE】【6】【*】,display will show “SPECIAL FUNCTION”, then do selection as following.

If print price unit

Weight unit print

If print weight unit

Print with motion

PLU NUMBER LENGTH

OPTIONS

0=do not round;

1=round price;

2=round cut;

3=round carry;

4=round 1/4

0=as default;

1=no not round;

2=round price;

3=round cut;

4=round carry;

5=round 1/4

0= /kg;

1= /500g;

2= /100g;

3= /50g;

4= /g

0= /kg;

1= /500g;

2= /100g;

3= /50g;

4= /g

0= print on label;

1=not print

0=kg;

1=g;

0= print on label;

1=not print

0=back to 20E;

1=without motion

2=with motion

0=disable;

1=enable

0=disable

1=enable

0=default config.;

1=customer zed

0=with [v..] key

1=press [*]then [V..]

0=no limitation

1=enter PLU length

DESCRIPTION

Country selection

Select round price method

After discount, round price

Select the unit of unit price

Select the unit of printing on label

If print unit of unit price on label

Select weight unit for printing

If print weight unit on label

Select if print label as weight changed

6/15Kg, 20e=40g,

15/30Kg, 20e=100g

If print as amount 0

Select items in create PLU menu

Select call PLU method

50

20

21

ET LINK TO PLU

PRICE OPEN TYPE

1=without zero prefix

0=not link to PLU

1=link to PLU

0=depends on PLU

1=all enable

2=all disable

1=all enable

2=all disable

24

25

OPEN PRICE MARK

OPEN PRICE MODE

1=all enable

2=all disable

0=free price

1=lower price

0=temporary

1=permanent

26

27

28

FIX WEIGHT

FIX KEY

FIX KEY IN PREPACK

29 2 ND LABEL PRINT

0=as fix weight

1=as by_cnt unit

2=minimum weight

0=fix key active

1=fix key inactive

0=fix key active

1=fix key inactive

0=disable

1=enable

30 Select Year Length 0=YY 2 digits;

1=YYYY 4 digits

0=YYMMDD

1=DDMMYY

2=DDMMYY(CHR)

3=MMDDYY

4=DDMMMYY(CHR)

32 DATE 0=”/”

1=”.”

2=”,”

3=”-”

1=12 hours

PLU:XXXX,LEFT:YYYY

35 SELL BY FORMAT 0=not print today

1=print today

0=by label 36 PACK DATE FORMAT

1=by best before

2=by sell by

37 WIRELESS 0=without wireless

1=with wireless

1=display PLU l1

2=scrolling PLU l1

3=display PLU l2

4= scrolling PLU 2

Set the Extra text number the same as the PLU number

Select if all PLUs allow to change price temporary

Select if all PLUs allow to discount price

Select SPECIAL OFFER method

Price change limitation

If save the temporary price to

PLU

Select FIX WEIGHT item function

Select FIX KEY enable or disable

Select FIX KEY enable or disable in PREPACK mode

Select if print second label

Select the year format

Select date format on display and receipt (not label)

Select separator between date

Display the PLU quantity and left space

Select start date of sell by

Select if print pack date

If use wireless

Select PLU description display mode

51

40

41

42

Precious Price

IP VALID CHECK

Switch net mode

Precious Price 0.00

0=NO

1=YES

0=NO

1=YES

43

46

Display negative weight

PLU NO. Length

0=NO

1=YES

44 Change 0=Chinese

1=English

2=France

3=Turkish

4=Polish

0=6 digits

48

50

EAN 13 Style

PLU Display Font

1=8 digits

0=standard

1=special

0=Normal

1=with [*] key

0=Small font

1=Big font

Higher than this price will give a warning message when sell a by weight PLU.

If Check the last digit of IP address

As you set get PLU from network server, when the scale can’t get PLU scale will change to get from local scale

If display negative weight

Select language

Select PLU length

Select call PLU method in prepack mode

Select PLU display font size

52

Label definition

Enter the menu【CODE】【7】【*】,display will show “LABEL DEFINITION”, then enter following submenu. Example to set SERVICE BY WEIGHT label:

After press 【CODE】【7】【*】,then press 01【*】, input label number, press 【*】 key confirm.

01SERVICE BY WEIGH

02SERVICE BY COUNT

03PREPACK BY WEIGH

04PREPACK BY COUNT

05TOTAL LABEL

06COPY LABEL

07DELETE LABEL

Password setting

Enter the menu【CODE】 【 *】,display will show “PASSWORD SETTING”, then select following submenu to set.

NO. MENU

01 STANDARD CONFIG

02 MANAGER PASSWORD

03 SCALE PASSWORD

PARAMETER

MANAGER PASSWORD?

NEW PSW _ _ _ _

NEW PSW _ _ _ _

DESCRIPTION

Clear all passwords of the scale. If you have set the ADMINISTRATOR password you should input the manager password first.

Set the ADMINIDTRATOR password.

Set the power on password of scale.

04 CODE PASSWORD

05 PRICE CHANGE PSW

06 DISCOUNT PSW

NEW PSW _ _ _ _

NEW PSW _ _ _ _

NEW PSW _ _ _ _

MANAGER PASSWORD?

Set the password for entering [CODE] menu.

Set the password for changing price.

Set the password for discounting.

Clear each password one by on. If you have set the ADMINISTRATOR password you should input the manager password first.

0:NO PASSWORD

1:MANAGER PSW

2:VENDOR PSW

Set the password to exit screensaver.

53

Service function

Enter the menu【CODE】【9】【*】,display will show “SERVICE FUNCTION”, then do following operation..

NO. MENU PARAMETER DESCRIPTION

Test the scale display,keyboard etc

Test scale memory

05 CALIBRATION

09 TICKET NO. TO 0

17 DELETE ALL PLU

18 DELETE ALL GROUP

19 DEL. ALL OPERATOR

28 HEAD CLEAN ALERT

29

CHG PAPER MSG

0=no

1=yes

0=CONFIG NO;

1=CONFIG YES

0=no

1=yes

0=no

1=yes

0=no

1=yes

0=NOT CLEAR

1=CLEAR

0=ENABLE IN PP.

1=DISABLE IN PP

0=Enable

1=disable

0=Enable

1=disable

Test scale RS232

Display increment X10

Calibrate the scale

Set the scale number

Reset the ticket number to zero.

Print out fonts table

Reset scale

Set IP address of scale

Enter update firmware state

Test printer with ticket

Test printer with label

0=DISABLE ALERT

1=ENABLE ALERT

54

34 CASH DRAW TEST

START CHAR – END CHAR

Test the cash drawer

If you use wireless scale, please configure the wireless option here

Input the Unicode range of the char you want to check.

Function test

01【*】

【*】

This function used to test the display, keyboard and printer.

Enter the function, and light on all the display to check if the display is ok.

Display 1234... testing, then scale will print out a ticket to check the printer.

At last which will test the keyboards, you should press the key one by one according to the message.

Memory test

02【*】

This function used to test scale memory.

Enter the memory test, scale will test it automatically, then print out the test report, also give some information if something is wrong.

Interface test

03【*】

This function used to test RS232 com part. Before the test you should shorten the PIN 2 and PIN 3 of the COM port.

Enter the test and scale will give you message in 5 minutes.

After the test, take out shorten wire.

High resolution display

This function used to watch the high resolution of the scale. Use it you can check the

55

loadcell and A/D pcb.

04【*】

"PUSH CAL BUTTON” Enter the menu, press the calibration button Display the high resolution. Press key【C】 to exit.

Primary configure

08【*】

(scale number)【*】

This function used to set the scale number.

Enter the menu “Primary Config”

Input scale number

Reset ticket number

09【*】

0or1

This function used to reset ticket number.

Enter the menu

Select if reset it

0:no

1:yes

【*】

Clear BRAM

12【*】

0or1

【*】

This function used to clear all the data in BRAM, including the PLU DATA, SET UP DATA etc.

Enter the menu

Select the item

0:not clear

1:clear

Fonts tabel

13【*】

This function used to list the fonts table in scale.

Enter the menu and print out the fonts list.

56

Reset scale as default

This function used to reset the scale as factory default. This will clear all programmed data and reports, but not clear the calibration data.

15【*】

0or1

_

Enter the menu

Select the item

0:not reset

1:reset

Usually we should also make sure that we made the right country selection. Go

【 CODE】6【*】01【*】

01【*】 input the Country code

【*】 Reset default 0or1 to the country finish menu.

Enter Country Finish menu

Enter Country selection e.g. 00: China; 04: Singapore.

0: not reset to country default

1: reset to country default

Clear all PLU data

17【*】

0or1

【*】

This function used to clear all PLU data in the scale.

Enter the menu

Select item

0:not clear

1:clear

Clear Group

18【*】

0or1

This function used to clear group in the scale.

Enter the menu

Select item

0:not clear

1:clear

【*】

Clear operator

19【*】

0or1

【*】

This function used to clear all the operator data of the scale.

Enter the menu

Select item

0:not clear

1:clear

57

Network configure

This function used to set IP address, net mask, server IP, and router IP etc.

21

SERVICE MODE

_

NETWORK CONFIG

*

IP ADDRESS

_

NET MASK

_

SERVICE IP

_

ROUTE IP

_

IDLE TIME

_

_

_

_

MAC ADDRESS

_

_

10

_

Enter the preset code 21.

Enter network configure

Input IP address

Input NET MASK address

Input SERVER IP address (If necessary)

Input ROUTE IP address (If necessary)

Input IDLE TIME (10 is ok)

Scale will restart automatically.

After completing setup, if necessary you can choose the PLU SOURCE. The operation as bellow:

K9* Call the menu "Technical service "

SERVICE MODE

21

_

NETWORK CONFIG

*______

PLU SOURCE

_

CODE

0.00 0.00 0.00

0-2

Enter the preset code 21.

0=Get PLU from local scale

1=Get PLU from NETWORK

2=First from network, then from local scale

Press K to exit.

58

Ticket print test

Label Printer Test

This function used to test the printer with ticket.

24【*】 Enter the preset code 24.

DISPLAY DESCRIPTION

RESIST 600-999 850 Select the Ohms Rating marked on the

Print Head.

SPEED 105 MM/S 0-5 Select the printer speed:

0=125mm/s; 1=115mm/s;

2=105mm/s; 3=95mm/s; 4=85mm/s;

5=75mm/s

ENERGY -4 -- +4 0 Enter print density (use CNT/WT CHANGE key to input negative value)

PAP.END DET. NO 0-1 Enable paper end detecting (i.e. enable the take label sensor)

0= disable; 1=enable

PRINTERTEST NO 0-1 Conduct printer test (To print out test ticket)

0= No; 1=Yes

SENSORTEST NO 0-1 Conduct gap sensor test

0= No; 1=Yes

PAPER: ⇑ ⇓

SENSOR OK OK=*

Slowly remove the ticket and insert the ticket again in 10 seconds. The test result will be shown.

This function is used to test label printer hardware and adjust printer parameters.

25【*】 Enter the preset code 25.

DISPLAY DESCRIPTION

RESIST 600-999 850 Select the Ohms Rating marked on the

Print Head.

SPEED 85 MM/S 0-5 Select the printer speed:

0=125mm/s; 1=115mm/s;

2=105mm/s; 3=95mm/s; 4=85mm/s;

5=75mm/s

ENERGY -4 -- +4 0 Enter print density (use CNT/WT CHANGE key to input negative value)

PAP.END DET. NO 0-1

REWIND NO 0-1

Enable paper end detecting (i.e. enable the take label sensor)

0= disable; 1=enable

Enable rewind feature

0= disable; 1=enable

OFFSET 35 Enter offset length in mm (Eject distance)

59

TAKEUP THRESHOLD

100

Enter the threshold of take up sensor

PRINTERTEST NO 0-1 Conduct printer test (To print out test ticket)

SENSORTEST NO 0-1

0= No; 1=Yes

Conduct gap sensor and take label sensor test

0= No; 1=Yes

LABEL POS OK=*

LABEL TEAR OK=*

SENSOR OK OK=*

Lead the label to the start position manually. The scale will test gap sensor.

The scale will test take label sensor

The scale will issue two or three labels and show the test results.

Configure RS232

26*

0or1or2or3or4or5or6

This function is used to set the COM Port parameters.

_

0or1

_

0or1or2

_

0or1

_

0or1

_

Enter the menu

Baud rate

0:300 7:38400

1:600 8:57600

2:1200 9:115200

3:2400

4:4800

5:9600

6:19200

Databits

0:5 digits

1:6 digits

2: 7 digits

3:8 digits parity

0:no

1:odd

2:even

Stop bit

0:1 digit

1:2 digits

0:Procedure;1:Procedure 7 EIN

60

Reports

05

GROUP

REPORT

【*】

Enter the menu【CODE】【2】【*】,display will show “REPORT CONFIG.”, then do following operation..

"DEFAULT YES" (press key: 0=YES,1=NO)

【*】

【*】

【*】

【*】

【*】

"TODAY "

(press key:0=today,1=last day,2=total,3= all)

"SIMPLE RPT" (press key [↓]to select simple or detail report)

"NOT PRINT" (press key [↓] to select print or not print report)

【*】

【*】

【*】

【*】

"TODAY "

(press key:0=today,1=last day,2=total,3= all)

"ALL PLUS" ([↓] to select the PLU range or all plu)

"FROM PLU NO.0" 【 *】 "TO PLU NO. 0"(PLU range)

"SORT BY SUM" ([↓] to sort by PLU or by total)

"NOT PRINT" (press key [↓] to select print or not print report)

【*】

【*】

【*】

"TODAY " (0=today,1=last day,2=total,3=all)

"NOT PRINT" ((press key [↓] to select print or not print report)

【*】

【*】

【*】

"TODAY "

"ALL GROUPS"

(0=today,1=last day,2=total,3=all)

([↓] to select GROUP range or all group)

61

【*】

【*】

【*】

【*】

06 GROUP H REPORT

【*】

【*】

【*】

【*】

【*】

【*】

【*】

【*】

【*】

【*】

【*】

【*】

【*】

【*】

【*】

62

"FROM GROUP

NO.0"

*】 "TO GROUP NO. 0"(GROUP range)

"SORT BY SUM" ([↓] to sort by PLU or by total)

"SIMPLE RPT"

"NOT PRINT"

([↓] to select detail report or simple report)

(press key [↓] to select print or not print report)

"TODAY " (0=today,1=last day,2=total,3=all)

"ALL GROUPS" ([↓] to select GROUP range or all group)

"FROM GROUP

NO.0"

*】 "TO GROUP NO. 0"(GROUP range)

"SORT BY SUM" ([↓] to sort by PLU or by total)

"NOT PRINT" (press key [↓] to select print or not print report)

"TODAY " (0=today,1=last day,2=total,3=all)

"NOT PRINT" (press key [↓] to select print or not print report)

"SETTLE $ YES" (press key [↓] to select YES or NO)

"TODAY " (0=today,1=last day,2=total,3=all)

"SIMPLE RPT"

"NOT PRINT"

([↓] to select detail report or simple report)

(press key [↓] to select print or not print report)

"TODAY " (0=today,1=last day,2=total,3=all)

"PRINT" (press key [↓] to select print or not print report)

【*】

【*】

【*】

【*】

【*】

【*】

【*】

【*】

【*】

【*】

【*】

【*】

【*】

【*】

【*】

【*】

【*】

【*】

【*】

12

CASHDRAW

REPORT

"TODAY " (0=today,1=last day,2=total,3=all)

"ALL VENDORS" ([↓] to select VENDOR range or all VENDORs)

"FROM VENDOR

NO.0"

【 *】

"TO VENDOR NO. 0" ( VENDOR range)

"SORT BY VEN" ([↓] to sort by VENDOR or by total)

"SIMPLE RPT"

"NOT PRINT"

([↓] to select detail report or simple report)

(press key [↓] to select print or not print report)

"TODAY "

"NOT PRINT"

(0=today,1=last day,2=total,3=all)

(press key [↓] to select print or not print report)

"NOT PRINT" (press key [↓] to select print or not print report)

"NOT PRINT" (press key [↓] to select print or not print report)

"NOT PRINT" (press key [↓] to select print or not print report)

"202 SALES RPT NO"

"203 PLU RPT

NO"

"204 PROMOTE RPT NO"

63

【*】

【*】

【*】

【*】

【*】

【*】

【*】

【*】

【*】

【*】

【*】

【*】

"205 GROUP RPT NO"

"206 GROUP H RPT NO"

"207 HOURLY RPT NO"

"208 SETTLE RPT NO"

"210 ST/RETN RPT NO"

"211 VENDOR RPT NO"

"212 CASHDRAW RPT NO"

"213 WEEKLY RPT NO"

"214 MONTHLY RPT NO"

"215 YEARLY RPT NO"

"NOT PRINT" (press key [↓] to select print or not print report)

"DELETE NO" (Press key:0=NO,1=YES)

PC software

【*】

【*】

PLU records and setup data of the bPro can be programmed through a PC (Personal

Computer) using the METTLER TOLEDO program bSoft and bLabel New scales can be easily set up by using this program.

Which requires an IBM or compatible PC with Windows 2000 or higher version operating system. One serial port or Ethernet port is required. The wiring diagrams shown in the following figure can be used to make cables from a 9-pin PC serial port to the 9-pin connector at the bPro. Factory cables are available from METTLER

TOLEDO using the part numbers shown in the figure.

123848OTC Cable, PC DB9 to bPro 10ft/3m

2 3

PC

DB9-F

TO 9-PIN SERIAL

RS232 PORT

3

5

2

5 bPro

DB9-F

TO 9-PIN SERIAL

RS232 PORT

64

Flashing Software

The bPro Operating System Software is retained in Flash EEPROM's on the Main

Logic PCB. The EPROM's can be reprogrammed using a PC and a downloader program Hyper terminal. Cables and components are the same as above RS232 cable.

Before downloading the software, turn the bPro power OFF. Connect one end of the cable to the PC's serial port and the other end to the bPro serial port.

Press the 【PRINT】key as power on the scale.

The scale will display “WAIT FOR HOST……” to wati for PC signal.

Then enter the Hyper terminal, to select right COMM port of the computer.

Then set the data as “baud tare 115200, data bits 8, parity none, stop bits

1,flow control none”

After come back main interface of the Hyper terminal, to select “ send file” ,select the scale code and the protocol as “1K Xmodem”. Send the file to scale.

The PC screen will display a status menu to show the flashing progress. When the flashing is completed, the scale will reset automatically. Press any key to exit

Hyper terminal program at the PC.

Also you can use a kit made of Mettler-Toledo which can update the firmware via Ethernet. First connect the Ethernet cable from scale’s RJ45 to computer.

If you use Ethernet to update, hold the [00] key to power on scale, before it you should set the scale’s IP address.

Also you should make some setting in PC kit, that will be introduced in software.

65

66

4

Troubleshooting

Troubleshooting Guide

Following is a list of symptoms that could occur, and the recommended action to correct the problem.

SCALE INOPERATIVE/BLANK DISPLAYS

1. Check AC power at outlet.

2. Check Voltage on Main Logic PCB. If voltages are zero, check Power Supply.

3. If test point voltage is good replace Main Logic PCB.

4. Check Display Cable on Main Logic PCB and Operator Display PCB. Check

Display PCB.

KEYBOARD INOPERATIVE a) b) c)

1. Check keyboard connection on keyboard controller PCB.

2. Check Keyboard controller connection to Main Logic,

ensure all connections are secure.

3. If all connections are secure and keyboard is inoperative:

Replace keyboard controller PCB.

Check keyboard once again.

If Keyboard is still inoperative, replace keyboard.

SCALE WON'T ZERO (DISPLAY "PUT PLATTER ON" or "ZERO NOT CAPTURE")

1. Check platter and spider for obstructions. Turn power off, then back on.

2. Recalibrate.

3. Check Load Cell supply voltage.

4. Replace Load Cell.

LOSING PROGRAMMED DATA

1. Check Error Report of Service Mode.

2. Check Main Logic voltage at test points.

3. Replace Main Logic PCB.

PRINTER WON'T DELIVER LABEL

1. Check printer for obstructions.

2. Check if there is a label which has not been removed.

3. Check Take Label sensor obstructions.

4. Clean Take Label sensor.

5. Test Take label sensor with SENSOR TEST in Service Mode.

6. Check harness from Printer to Main PCB.

7. Check label stepper motor.

8. Replace Main Logic PCB.

INCORRECTLY INDEXES LABELS

1. Check label installation.

2. Check label format and label size.

3. Clean Gap Sensor Lens.

4. Check and clean platen roller, stripper bar, and delivery path using MT cleaning pen.

5. Adjust label Gap Sensor through SENSOR TEST in Service Mode.

6. Replace Gap Sensor Assembly.

7. Replace Main Logic PCB.

LABELS DARK

1. If labels are printed correctly, but are excessively dark, check the ENERGY setting in

Service Mode.

2. Check printhead harnesses for loose wires.

LABELS MISSING DOTS

1. If the labels are streaked by lines from top to bottom, replace the

Printhead.

2. If characters are cut off, check label format programming. If OK, replace printhead.

LABELS ARE EXCESSIVELY LIGHT/DARK

1. Check Print SPEED and ENERGY setting in Service Mode.

2. Check with other known good label stock.

3. If light print, check and clean printhead resistor line and platen roller.

4. Check printhead harness for loose wires.

5. Check Main Logic PCB voltages. If OK, replace Printhead.

LABEL PRINT IS MOTTLED WITH LIGHT SPOTS

1. Check with other known good label stock.

2. Check and clean printhead resistor line and platen.

3. Replace printhead.

LABELS NOT STRIPPING CORRECTLY

1. Check with other known good label stock, e.g. Nashua.

2. Check label format programming.

3. Check rewind spool for wear.

4. Check Gap Sensor and Take Label Sensor with SENSOR TEST in Service Mode.

LABELS PRINTED EVEN IF ONE IS NOT YET TAKEN

1. Check PAP. END DET. option in Service Mode (Paper End Detection)

2. Check Take Label Sensor.

3. Check Main Logic PCB.

OUT OF LABELS ERROR

1. Make sure labels are threaded through the Gap Sensor.

2. Clean/Check Gap Sensor.

3. Check Gap Sensor through SENSOR TEST in Service mode.

4. Replace Gap Sensor.

5. Replace Main Logic PCB.

CAN'T COMMUNICATE WITH PC

1. Test scale serial port through INTERFACE TEST in Service Mode.

2. Check the connection cable.

3. Check which serial port is used at PC.

4. If using bSoft, check the COM PORT SETUP and set to the following parameters:

Data bits: 8

Parity: None

Stop bits: 1

67

68

POWER SUPPLY

Flow control: None

Following is a list of symptoms that could occur, and the recommended action to correct the problem.

Place the Power Switch to the OFF position. Remove the platter, spider, and top cove.

To check the +24VDC output voltage from the Power Supply terminal between the terminals marked +V and GND, the acceptable output range is +24VDC +/-0.50 VDC.

If the voltage is normal, the Power Supply should be good, and the problem should be suspected as being in the Main Logic PCB or a component that connects to the Main

Logic PCB.

If the output voltage is zero, check the 120 VAC input voltage. If the correct AC input voltage is present, but there is no +24 VDC output, replace the Power Supply.

If no voltage is present, check the fuse (240VAC 4A) on the power supply. If the fuse is OK, check AC input at the Line Cord Jack between the Red wire and Black wire. If the 120VAC is present, suspect a defective power switch. If 120 VAC is not present at the jack, check the fuse (240VAC 3A) installed in the Line Cord Jack, as shown in the following Figure. If the fuse is OK, verify voltage is present at the AC wall outlet. working fuse backup fuse

Main Logic PCB

The Main Logic PCB receives +24VDC from the Power Supply and uses this to supply +10VDC and +5VDC to other components. The Main Logic PCB controls all functions in the unit including the thermal printer. Inputs and Outputs to the

Main Logic include the Label Taken Sensor, Gap Sensor, Printhead, Stepper

Motor, Rewind Motor, Load Cell and etc. The following Figure shows the locations of the various components and connectors on the Main Logic PCB.

If the volages are not within the range specified, and the Power Supply voltage is correct, replace the Main Logic PCB.

NOTE: WHEN REPLACING THE MAIN LOGIC PCB, THE UNIT MUST BE

REFLASHED.

69

70

Load Cell

The Load Cell can be tested for proper analog voltage input and millivolt output by measuring the voltage on the Main Logic PCB. To check the input voltage across +EXC & -EXC, place your meter on volts and put the positive lead on the left pin of F1 and the negative lead on the left pin of F4. You should be reading a steady +10VDC +/- 0.25VDC.

If the Excitation voltage is good, the signal output can be checked across +SIG &

-SIG. Set the meter to read in millivolts (mV). Put the positive lead on the left pin of F2 and negative lead on the left pin of F3. With no weight on the platter, you should read zero data. As you add weight to the platter, the voltage should rise and be linear if equal weight is added each time. If the output is linear and correct, but no weight is displayed, replace the Main Logic PCB. If there is no output from the load cell, but correct input voltage, replace the load cell.

Warning Message

INPUT TOO BIG

The input is too big.

INPUT TOO SMALL

The input is too small.

TOO MUCH INPUT

The input is out of limit.

WRONG CODENR.

The code number is invalid.

KEY NO FUNCTION

The key has no function.

KEY BLOCKED

The key is disabled. Check the KEYBOARD CONFIGURE.

PLU NOT FOUND

The entered PLU number does not exist.

AG NOT FOUND

71

72

The entered Group number does not exist.

OPER.NOT FOUND

The entered Operator number does not exist.

LABEL NOT FOUND

The entered Label Format does not exist.

PLUNR IS OCCUP

You are trying to duplicate a PLU into an exist PLU number.

LABELNR. OCCUP

You are trying to duplicate a label format into an exist label format number.

AG NOT DELETABLE

This Group contains total data and can not be deleted.

OP NOT DELETABLE

This Operator contains total data and can not be deleted.

MEMORY FULL

Memory is full.

WEIGH AGAIN

You are trying to record one item twice. Remove the item from the platter and put a new item on the platter.

WRONG LABEL

The installed label roll does not match the configured label format.

LABEL MOVED

The stepper motor or the rewind motor is not working properly.

CHANGE PAPERROLL

The label roll is not installed or the label roll is empty.

TAKE LABEL OFF

Take off the current label before printing the next one.

NO FREE OX KEY

All the configured operator keys have been occupied.

PRINT TICKET

Print out the customer ticket before logging out.

OPEN CUST. TICK

You are trying to delete an operator who has total data.

OX NOT LOGGED-IN

The operator has not be assigned to an operator.

PAYMENT TOO LOW

The payment is less than the total amount.

NO FURTHER REG.

Error Message

No further transaction has been recorded.

DISCOUNT IMPOSS

This PLU does not allow to be discounted. Check the PLU Discount configuration, or this PLU is in special offer.

TARE TOO BIG

The entered tare is too big.

PLU TARE ACTIVE

You are forbidden to override the PLU tare.

NO STABLE WEIGHT

The weight is not stable.

PUT PLATTER ON

The weight is too small and out of power up zero range.

ZERO NOT CAPTURE

The weight is too big and out of power up zero range.

WEIGHT TOO SMALL

The weight is too small to be printed.

ERROR TAKE-SENS

The take label sensor is not working properly.

ERROR POS_SENS

The gap sensor is not working properly.

ERROR INTERFACE

The serial port is not working properly.

Listed below are the possible error codes. When an error code appears, the scale should be switched off and on. In many cases the error will disappear.

There are 3 different kinds of error messages:

Error Status 1:

Warning! After the warning the scale can still be used.

Error Status 2:

Press "CODE" key. Change to one of the CODE menu. Back to normal operation mode.

Error Status 3:

Press "CODE" key and enter SERVICE MODE, after returning to normal operation mode the scale will perform RESET.

73

Error Message

ERROR 300 PRINTER

ERROR 301 PRINTER

ERROR 307 PRINTER

ERROR 308 PRINTER

ERROR 310 PRINTER

ERROR 101 AP

ERROR 400 CELL

ERROR 401 CELL

ERROR 200 DATABASE

ERROR 201 XX DATABASE

ERROR 202 XX DATABASE

ERROR 203 YY DATABASE

ERROR 205 DATABASE

Reason

Printer driver defect

Printer driver defect

Printhead defect

Printer driver defect

Printer driver defect

Real Time Clock defect

Load Cell defect

Load Cell defect

Data bank error

XX Data error

XX Data error

YY Data error

Data bank error

2

1

Status Action

2

2

2

1

Replace Main Logic PCB

1 Reflash the software

2 Replace Main Logic PCB

1 Replace printhead

2 Replace printhead harness

3 Replace Main Logic PCB

Replace Main Logic PCB

-

Replace Main Logic PCB

Replace Main Logic PCB

1 Replace Main Logic PCB

2 Replace Load Cell

-

3

2

2

2

3

1 Recalibrate

2 Replace Main Logic PCB

3 Replace Load Cell

Reset RAM

1 Reset RAM

2 Delete Data XX

1 Reset RAM

2 Delete Data XX

1 Reset RAM

2 Configure Y Y

Reset RAM

Meaning of XX

02 Ticket data

07 data

13 Label data

03 Time total data

04 Text data

15 Date text data

21 PLU label data

Tare PLU

Meaning of YY

01 Operator Configure

03 Keyboard Configure

04 Password Configure

74

Interconnecting Diagram

75

5

Parts Replacement

Replace main PCB

!

all the data saved in main PCB, as you change the main PCB you will lose all of them.

Counter type

• Power off and take out the power cable from electrical outlet.

• Take away platter.

• Screw out the 5 bolts (A) from base and take away.

• Show main PCB.

• Pull out all connection from main PCB.

• Screw out 6 bolts (B) from main PCB, take away it.

Install main PCB

• Put the main PCB to right position, screw in 6 bolts of main PCB.

• Put the cover of base then screw in 5 bolts.

76

• Put on platter.

• Power on scale.

Hanging type:

bPro -H2

A3

B3

Take out main PCB

• Power off and take out the power cable from electrical outlet.

• Take away platter.

• Screw out the 2 bolts (A3) from scale and take away.

• Screw out 4 bolts (B3) from scale and show main PCB.

• Pull out all connection from main PCB.

• Screw out 4 bolts (C3) from main PCB, take away it.

Install main PCB

• Put the main PCB to right position, screw in 4 bolts of main PCB.

• Connect all harness to main PCB.

• Put the display and power support kit to position, screw in 4 bolts.

C3

77

• Put the cover of display then screw in 2 bolts.

• Install whole hanging scale.

• Put on platter.

• Power on scale.

Replace switch power

Counter type:

Take out switch power

• Power off and take out the power cable from electrical outlet.

• Take away platter.

• Screw out the 5 bolts (A) from base and take away.

• Pull out the harness in switch power.

• Screw out 4 bolts in the power PCB.

• Take away the switch power.

Install switch power

78

• Put the switch power to the right position.

• Screw in 4 bolts of the power PCB.

• Plug in all the connection harness in the PCB.

• Put the cover of base then screw in 5 bolts.

• Put on platter.

• Power on scale.Hanging type:

bPro -H2

D3

E3

Take out switch power

• Power off and take out the power cable from electrical outlet.

• Take away platter.

• Take away the back display cover and back display kit as before.

• Screw out the 2 bolts (D3) from base and take away.

• Show the switch power.

• Pull out the harness in switch power.

• Screw out 4 bolts (E3) in the power PCB.

• Take away the switch power.

Install switch power

• Put the switch power to the right position.

• Screw in 4 bolts of the power PCB.

• Plug in all the connection harness in the PCB.

• Put the support plate then screw in 2 bolts.

• Install back display kit.

• Install whole hanging scale.

• Put on platter.

• Power on scale.

79

Replace display

Counter type

Take out display

• Power off and take out the power cable from electrical outlet.

• Take away platter.

• Take away the tower kits.

• Screw out 2 bolts in the display cover, and take out the front cover, show the display.

• Screw 5 bolts of the front display, pull out harness and take away the display.

• Screw 4 bolts of back display and pull out harness, take away back display.

Install display

• Put the back display to right position and screw in 4 bolts to fix it.

• Plug in harness of display.

• Also the harness to front display.

• Put on the front display.

• Screw in bolts for installation.

• Put the front display.

• Screw in 2 fix bolts of cover.

80

• Install the tower to base.

• Put on platter.

• Power on scale.

Hanging type:

bPro -H2

F3

Take out display

• Power off and take out the power cable from electrical outlet.

• Take away platter.

• Take out back display kit as previous method.

• Take away display harness in display.

• Screw out 4 bolts (F3) in the display support plate, and take out the back display.

• For front display, you should also take away the main PCB and power PCB, then to show the front display, screw out 4 installation bolts.

Install display

• Put the back display to right position and screw in 4 bolts to fix it.

• Plug in harness of display.

• Install the back display kit.

• Install back display cover.

• Install whole hanging scale.

• Put on platter.

• Power on scale.

81

Replace load cell

Counter type

82

Take out loadcell

• Power off and take out the power cable from electrical outlet.

• Take away platter.

• Screw out 2 bolts for fix the cover of print paper (D).

• Take out the cover (E).

• Screw out 2 bolts in interface PCB (F).

• Screw out 4 bolts in up spider, and take out it.

• Open the sealing screw (G).

• Take away up cover.

• Pull out loadcell harness from main PCB.(see above to find the main PCB)

• Screw 2 screws in loadcell and take out spacer.

• Also take out loadcell spacer.

• Also screw 2 screws for installing loadcell under the scale.

• Take away loadcell.

Install loadcell

• Put the loadcell to right position.

• Install 2 screws from scale bottom.

83

• Screw down with moment spanner.15kg CAPACITY with 8 NM,

30kg CAPACITY with 10 NM.

• Put the spacer and then screw down 2 screws in it.

• Screw down with moment spanner.15kg CAPACITY with 8 NM,

30kg CAPACITY with 10 NM.

• With X mm ruler to adjust the limit size of back 2 screws. With Y mm ruler to adjust the limit size of front 2 screws inspacer.(capacity:6/15kg X=1.2mmY=0.9mm;capacity:15/30kg X=1.9mmY=1.3mm)

• Insert the loadcell harness to main PCB.

• Install the up cover, print paper cover,up spacer,screws in interface PCB, cover of main PCB at bottom etc.

• Adjust 4 screws in up spacer and let the spacer levelly.

• Put on platter.

• Power on scale.

Hanging type:

bPro-H2

G3

H3

I3

J3

Take out loadcell

84

K3

L3

M3

• Power off and take out the power cable from electrical outlet.

• Take away platter.

• Screw out 2 bolts (G3) for fix the left cover.

• Take out the cover.

• Screw out 2 bolts (H3) in base.

• Take away A/D convertor kit (I3).

• Screw out 2 bolts (J3),take out the cover.

• Screw out bolt (K3) and bolt (L3) for connecting load cell.

• Screw out 2 bolts (M3).

• Take out loadcell.

Install loadcell

• Put the loadcell to right position.

• Use reverse steps to install the load cell as previous take out steps.

85

Replace keyboard

Counter type

Take out keyboard

• Power off and take out the power cable from electrical outlet.

• Take away platter.

• Screw out 3 bolts (H) in keyboard at bottom.

• Take out keyboard and cover kits.

• Pull out the harness of keyboard from the keyboard convert PCB.

• Rip off the keyboard overlay, take out it.

Install keyboard

• Clean the keyboard cover with alcohol, and wait it till dry.

• Let harness through the hole in it and rip off the protect paper in keyboard, then stick it to the keyboard cover.

• Plug in the harness to keyboard convert PCB.

• Put the keyboard to right position and install 3 bolts in it.

86

• Put on platter.

• Power on scale.

Hanging type: bPro-H2

Just use new one replace old one and hang it.

87

Replace printer

Counter type

I

88

Take out printer

• Power off and take out the power cable from electrical outlet.

• Take away platter.

• Screw out 2 bolts (I) at the bottom of the scale.

• Open the printer door.

• Pull out printer, also disconnect the harness in printer PCB and connect ground wire.

• Take out printer, also with sliding feet under it.

Install printer

• Put the sliding base to right position.

• Insert the harness of the printer PCB and connect the ground wire.

• Put the printer to right position and insert to scale carefully.

• Insert the sliding feet under the printer. Screw down 2 bolts for fixing the printer at bottom of scale.

• Close printer door.

• Put on platter.

• Power on scale.

89

Hanging type:

N3

bPro-H2

Take out printer

• Power off and take out the power cable from electrical outlet.

• Take away platter.

• Open right door of scale.

• Screw out 3 bolts (N3) at the bottom of the printer.

• Take out all harness in printer PCB.

• Take out printer.

Install printer

• Insert the harness of the printer PCB.

• Put the printer to right position and insert to scale carefully.

• Screw down 3 bolts for fixing the printer.

• Close printer door.

• Install whole hanging scale.

• Put on platter.

• Power on scale.

90

Replace printer head

J

!

DON’T GRIDE THE PRINTER HEAD.

Take out printer head.

• Power off and take out the power cable from electrical outlet.

• Take away platter.

• Open printer door, pull out printer.

• Screw out 2 screws (J) for fixing printer head.

• Pull out the harness from printer head.

• Take away printer head.

Install printer head

• Insert the printer head harness.

• Put the printer head and spacer to right position. Screw down 2 bolts.

• Close the printer head.

• Push the printer back to scale.

• Put on platter.

• Power on scale.

91

Install Wireless card

Counter type

! Steps as below. (counter type as example)

(A1)

(D1)

(G1)

(B1)

(E1)

(H1)

92

(C1)

(F1)

(I1)

(J1)

(M1)

(K1)

(N1)

(P1)

• Power off and take out the power cable from electrical outlet.

• Take away platter.

• Screw out bolts from up spider (C1) and screw out sealing bolts (D1).

(O1)

(L1)

• Take apart the main PCB cover in bottom (F1), also take apart the cover of scale as screw out the bolts in the bottom of scale.

93

• Put the wireless kit (A1) to the position (G1).

• Install the bolts to it (H1).

• Take out the seal from hole (I1).

• Put the Ethernet harness through the hole (J1).

• Connect the Ethernet harness to the Ethernet port (K) and fix the harness as picture (L1).

• Put the wireless card power harness through the hole (M1).

• Connect the wireless card power harness to the main PCB (O1).

• Then to install the scale cover, the up spider, the main PCB cover in bottom, seal switch bolts etc.

94

Install the memory extension board

D2

A2

E2

B2

C2

95

Install the memory extension board.

• Power off and take out the power cable from electrical outlet.

• Take away platter.

• Screw out bolts from up spider and screw out sealing bolts in scale.

• Get the memory extension board (A2)

• Find socket of extension memory in main PCB (B2).

• Install bolts (C2) to main PCB.

• Insert the memory extension board to it as (E2).

• Fix three install bolts (D2) to main PCB.

• Then to install the scale cover, the up spider, the main PCB cover in bottom, seal switch bolts etc to resume the scale.

96

6

Maintenance

External Cleaning

Cleaning Printhead

Turn the scale power off by placing the power switch to the OFF position (Press the "0" on the power switch). Disconnect power cord from outlet.

Use a soft clean cloth dampened with a mild detergent and water (or a mild cleaner) to wipe the exterior surfaces. Do not spray liquid directly on the unit. A mild spray cleaner can be used by spraying the cleaning cloth.

CLEAN PRINTHEAD USING METTLER TOLEDO LIQUID CLEANER OR

EQUIVALENT OR THE METTLER TOLEDO CLEAN PEN.

DO NOT SCRAPE THE PRINTHEAD WITH ANY OBJECT TO REMOVE GLUE OR

LABEL DEBRIS OR SEVERE DAMAGE MAY RESULT.

Turn the scale off by placing the power switch to the OFF position.

Disconnect power cord from outlet.

Open the plastic door on the right side of the scale.

Slide out the printer.

Press the trigger to open the print head.

Clean the print head with a soft clean cloth soaked in isopropyl alcohol,

METTLER TOLEDO liquid cleaner or equivalent, or the METTLER

TOLEDO Cleaning Pen.

Push back the print head until it clicks.

97

Rezeroing

Slide the printer in.

Close the plastic door.

This scale is equipped with an automatic zeroing device, which compensates for small weight change. This device is not activated when a package tare is compensated. After cleaning the dirt from the platter with the scale on, the display can read :

• a negative value

• or "_ _ _ _ _" segments can be lit.

Solution :

Press the ZERO key

If the message appears again :

Turn the scale off and back on again with the main power switch.

98

7

GEO Settings

The values for gravity adjustment are a series of two digit numbers in the range 0 to 31, as shown in the table below.

Geo. Value Table

North or south latitude in degrees and minutes

0 0

5 0

0’ - 5

46’ - 9 0

0

9 0

12

15

17

19

20

22

23

25

26

28

29

30

31

33

34

35

36

37

38

40

41

42

43

44

45

46

47

48

50

51

52

53

54

55

57

58

59

60

62

63

64

66

67

69

71

73

75

77

80

85

0

0

0

0

0

0

52’ - 12

0 44’ - 15

0

0

46’

52’

44’

6’

6’ - 17

0 10’ - 19

0 2’ - 20

0

0

0

45’ - 22

22’ - 23

0 54’ - 25

21’ - 26

45’ - 28

6’ - 29

0 25’ - 30

0 41’ - 31

0

0

0

0

0

0

0

10’

2’

45’

22’

54’

21’

45’

6’

25’

41’

0 56’

0 56’ - 33

0 31’ - 36

0 9’

0 9’ - 34

0 21’ - 35 0

0 21’

31’

0 41’ - 37

0 41’

0 50’ - 38

0 58’ - 40

0 50’

0 58’

0 5’ - 41

0 12’ - 42

0 5’

0

0 19’ - 43

0 26’ - 44

0

12’

19’

0 26’

0 32’ - 45

0 32’

0 38’ - 46

0 38’

0 45’ - 47

0 51’ - 48

0 45’

0 51’

0 58’ - 50

0 58’

0 6’

0 13’ 0 6’ - 51

0

0

13’ - 52

22’ - 53

0 22’

0 31’ - 54

0 31’

0 41’ - 55

0 41’

0 52’ - 57

0 17’ - 59

0 32’ - 60

0 52’

0 4’

0 4’ - 58 0 17’

0 32’

0 49’ - 62

0 30’ - 64

0 55’ - 66

0 49’

0 9’

0 9’ - 63 0 30’

0 55’

0 24’ - 67

0 57’ - 69

0 24’

0 57’

0 35’ - 71

0 35’

0 21’ - 73

0 21’

0 16’ - 75

0 16’

0 24’ - 77

0 24’

0

0 56’ - 85

0

52’ - 80

45’ - 90

0 52’

0 56’

0 45’

0 0’

0

325

325

650

650

975

2130

3200

18

18

19

19

16

16

17

17

14

14

15

15

12

12

13

13

10

10

11

11

9

9

8

8

7

7

6

6

5

5

4

4

26

26

27

27

24

24

25

25

28

28

29

29

30

22

22

23

23

20

20

21

21

0

1060

17

17

18

18

19

19

20

20

13

13

14

14

15

15

16

16

10

10

9

9

11

11

12

12

8

8

7

7

6

6

5

5

25

25

26

26

27

27

28

28

29

29

30

30

31

21

21

22

22

23

23

24

24

1060

2130

16

17

17

18

18

19

19

20

12

13

13

14

14

15

15

16

9

10

8

9

10

11

11

12

7

8

6

7

5

6

4

5

24

25

25

26

26

27

27

28

28

29

29

30

30

20

21

21

22

22

23

23

24

975

1300

Height above sea level in meters

1300

1625

1625

1950

1950

2275

3200

4260

Height above sea level in feet

4260

5330

5330

6400

6400

7460

17

18

18

19

15

16

16

17

13

14

14

15

11

12

12

13

9

10

10

11

8

9

7

8

6

7

5

6

4

5

3

4

25

26

26

27

23

24

24

25

27

28

28

29

29

21

22

22

23

19

20

20

21

17

17

18

18

15

15

16

16

13

13

14

14

11

11

12

12

10

10

9

9

8

8

7

7

6

6

5

5

4

4

3

3

25

25

26

26

23

23

24

24

27

27

28

28

29

21

21

22

22

19

19

20

20

16

17

17

18

14

15

15

16

12

13

13

14

10

11

11

12

9

10

8

9

7

8

6

7

5

6

4

5

3

4

2

3

24

25

25

26

22

23

23

24

26

27

27

28

28

20

21

21

22

18

19

19

20

16

16

17

17

14

14

15

15

12

12

13

13

10

10

11

11

9

9

8

8

7

7

6

6

5

5

4

4

3

3

2

2

24

24

25

25

22

22

23

23

26

26

27

27

28

20

20

21

21

18

18

19

19

2275

2600

7460

8530

13

14

14

15

15

16

16

17

9

10

10

11

11

12

12

13

7

8

8

9

6

7

5

6

4

5

3

4

2

3

1

2

21

22

22

23

23

24

24

25

25

26

26

27

27

17

18

18

19

19

20

20

21

2600

2925

8530

9600

13

13

14

14

15

15

16

16

9

9

10

10

11

11

12

12

7

7

8

8

6

6

5

5

4

4

3

3

2

2

1

1

21

21

22

22

23

23

24

24

25

25

26

26

27

17

17

18

18

19

19

20

20

2925

3250

9600

10660

14

15

15

16

12

13

13

14

10

11

11

12

9

10

8

9

7

8

6

7

5

6

4

5

3

4

2

3

1

2

0

1

22

23

23

24

20

21

21

22

24

25

25

26

26

18

19

19

20

16

17

17

18

3250

3575

10660

11730

14

14

15

15

12

12

13

13

10

10

11

11

9

9

8

8

7

7

6

6

5

5

4

4

3

3

2

2

1

1

0

0

22

22

23

23

20

20

21

21

24

24

25

25

26

18

18

19

19

16

16

17

17

99

8

Replacement Parts

72188012 bPro-C2

72188012 bPro-C2

Item P/N

1 180952

Description

上盖活动盖板 Label Roll Housing

2

3

183021

102326

秤盘组件 Platter

水泡 Leveling Bubble

100

Qty

1

1

1

4

5

6

7

124041 中心橡胶垫 Cap,Spider,,Center

154555 角垫 Cap,Spider,,Corner

180974 托 架 Spider

180943 上盖 Main Housing

8 174032 A/D 板 PCB Assembly,AD board

9(1) 72193829 键盘,透明硅胶按压层,bPro,C2 Keyboard,Touch pad,Silicon,bPro C2

1

1

9(2) 72209741 键盘,编程面板,bPro-C2,英文 Keyboard, Programming layer,bPro C2 ENG 1

9(3) 72193807 键盘,操作面板,bPro-C2,英文 Keyboard, Operation layer,bPro C2 ENG 1

1

4

1

1

9(4) 72193827 键盘,白色橡胶触点层,bPro,C2 Keyboard, Rubber button padding,bPro C2 1

9(5) 72193825 键盘,银浆电路层,bPro,C2 Keyboard, Membrane layer,bPro C2 1

10 72188155 键盘盖 C Keyboard Housing ,compact,top cover

11 173476 键盘转接板 PCB Assembly,keyboard convert

12 182976 调节支撑板 A Sheet Metal,Keyboard Swivel A

13 183450 支撑轴 Swivel Crutch shaft

14 180951 开关固定板 Sheet Metal,support ,Power Switch

15 72187455 电源线束 Harness,AC Power Socket

16 72187456 开关 Harness,AC power Switch

17 173307 接口板 PCB Assembly ,interface

18 167391 秤脚,秤体左侧长秤脚,bC/bPro FOOT,Long,left

19 72186444 接口固定板 Sheet Metal,Support,interface

20 72186386 开关电源 24v,2.7A Switching Power Supply,24v,2.7A

1

1

1

1

1

1

1

2

2

1

1

72186387 开关电源 24v,4.2A Switching Power Supply,24v,4.2A

21 169795 主板 PCB Assembly ,Main board,standard

72186557 主板 PCB Assembly ,Main board,Premium

22 183358 基座盖板 Sheet Metal,base cover

23 183359 键盘调节杆 Swivel adjustment support

24 180948 键盘座 Keyboard Housing,Base

25 150652 弹簧 Spring,keyboard Swivel

26 182877 调节支撑板 B Sheet Metal,keyboard swivel B

27 183452 固定轴 Swivel fixed Shaft

28 180973 基座 Aluminum Base Casting

29 72188140 秤脚,秤体右侧短秤脚 Foot,short,right

30 173596 直流线束 Harness,DC Power

31 180947 打印机侧门 Door

32 72191431 打印机组件 Printer Assembly,2" ticket

72191432 打印机组件 Printer Assembly,2" Label

33 182872 立杆固定座 Sheet Metal,support,Tower to base

34 72184997 AMI-22 传感器 Loadcell Assembly,AMI-22 for 6/15kg

72184996 AMI-40 传感器 Loadcell Assembly,AMI-40 for 15/30kg

72186985 AMI-11 传感器 Loadcell Assembly,AMI-11 for 3/6kg

72186878 AMI-40 传感器 Loadcell Assembly,AMI-40 for 30kg 6000e

1

1

1

1

2

1

1

1

1

1

2

1

2

1

1

1

1

1

2

1

101

72186875 AMI-40 传感器 Loadcell Assembly,AMI-22 for 12kg 6000e

35 72186402 导轨座 Printer Rail

36 72185419 垫 块 Loadcell spacer

37 72185423 钣金托架 Spider support

38 72188157 短盖板 B Plastic cover B,Front,Compact,bC/bPro-C2

39 72188192 立杆 C Tower, Compact,bC/bPro-C2

40 72188156 短盖板 A Plastic cover A,Rear,Compact,bC/bPro-C2

41 180946 压 板 B Sheet Metal,support B,Display

42 180954 显示盖锁紧件 Sheet Metal,support, disp to Tower

43 180945 压 板 A Sheet Metal,support A,display

44 155637 显示屏 Display Assembly,segment,CHN

72189191 显示屏 Display Assembly,segment,EURO

170120 显示屏 Display Assembly,segment,ENG

72202239 显示屏 Display Assembly,240X240

45 180944 显示外壳 Display Housing

46 72189327 滤光片 Display lens,CHN

183449 滤光片 Display lens,English

72193760 滤光片 Display lens,Euro,bc

47 156439 立杆线束 Harness,Customer display,

48 173248 线束,打印-主板 Harness,Main pcb to printer board

49 72187458 线束,接口-主板 Harness,Main pcb to interface

50 182252 键盘线束 Harness,Main PCB to keyboard

51 171790 显示转接线束 Harness,Segment Disp. convert

173345 显示转接线束 Harness,240x240 Disp. convert

52 72193070 显示盖板 Display Lens.Opaque,customer,bc/bpro-C2

53 72188193 显示滤光片 Display Lens.Compact,operator,bc/bpro-C2

54 122206 铅封纸 Sealing Sticker,EU,bC/bPro

55 72192054 铅封盖板 Sealing Cover,EU,bC/bPro

56 72224370 塑料线卡 Clip

57 72209420 小滑块 Slide space

58 72209419 导滑垫板 Slide base

B1 72204992 螺钉 M4X12,GB818-85 SCREW M4X12

B2 119054 铅封头 SEALING HEAD

B3 118549 铅封螺钉 SEALING SCREW

B4 72189609 螺钉 M4X8,GB818-85 SCREW M4X8

B5 72201470 带齿垫螺钉 M4X5 SCREW M4X5

B6 72201473 螺钉,M6X20,GB70-85 SCREW M6X20

B7 72192905 紧定螺钉,M5X16,GB79-85 SLOT SCREW

B8 72194324 螺母,M4 NUT M4

B9 72201474 自攻螺钉,M2.9X6.5,GB845 SCREW

B10 72201466 螺钉,M3X6,GB818 SCREW

102

2

1

1

1

2

2

2

2

1

1

1

1

1

1

1

1

1

1

1

1

1

21

4

4

2

9

1

2

15

6

18

1

1

1

1

1

1

1

1

1

1

B11 102661 弹簧垫圈 SPRING WASHERS

B12 72201469 螺钉,M4X14,GB819 SCREW

B13 142884 紧定螺钉,M3X8,GB79-85 SLOT SCREW

B14 143133 螺钉,M3X6,GB819 SCREW

72186380 bPro-T2

4

3

2

2

72186380 bPro-T2

Item P/N Description

1 180952 上盖活动盖板 Label Roll Housing

103

Qty

1

2 183021 秤盘组件 Platter

3 102326 水泡 Leveling Bubble

4 124041 中心橡胶垫 Cap Spider center

5 154555 角垫 Cap Spider Corner

6 180974 托 架 Spider

7 180943 上盖 Main Housing

8 174032 A/D 板 PCB Assembly,AD board

9(1) 72193830 键盘 透明硅胶按压层 bPro-T2 Keyboard,Touch pad,Silicon,bPro T2

9(2) 72193808 键盘 操作面板 bPro-T2 英文 Keyboard, Operation layer,bPro T2 ENG 1

9(3) 72193815 键盘 编程面板 bPro-T2 英文 Keyboard, Programming layer,bPro T2 ENG 1

1

1

1

4

1

1

1

1

9(4) 72193830 键盘 白色橡胶触点层 bPro-T2 Keyboard, Rubber button padding,bPro T2 1

9(5) 72193826 键盘 银浆电路层 bPro-T2 Keyboard, Membrane layer,bPro T2 1

10 180949 键盘盖 Keyboard Housing ,tower,top cover

11 173476 键盘转接板 PCB Assembly,keyboard convert

1

1

12 182976 调节支撑板 A Sheet Metal,Keyboard Swivel A

13 183450 支撑轴 Swivel Crutch shaft

14 180951 开关固定 Sheet Metal,support ,Power Switch

15 72187455 电源线束 Harness,AC Power Socket

1

2

1

1

16 72187456 开关 Harness,AC power Switch

17 173307 接口板 PCB Assembly ,interface

18 167391 秤脚 FOOT,Long,left

1

1

2

19 72186444 接口固定板 Sheet Metal,Support,interface

20 72186386 开关电源 24v,2.7A Switching Power Supply,24v,2.7A

72186387 开关电源 24v,4.2A Switching Power Supply,24v,4.2A

21 169795 主板 PCB Assembly ,Main board,standard

72186557 主板 PCB Assembly ,Main board,Premium

22 183358 基座盖板 Sheet Metal,base cover

23 183359 键盘调节杆 Swivel adjustment support

24 180948 键盘座 Keyboard Housing,Base

25 150652 弹簧 Spring,keyboard Swivel

26 182877 调节支撑板 B Sheet Metal,keyboard swivel B

27 183452 固定轴 Swivel fixed Shaft

28 180973 基座 Aluminum Base Casting

29 72188140 秤 脚 Foot,short,right

30 180975 导轨 Printer Rail Slider

31 173596 直流线束 Harness,DC Power

32 180947 打印机侧门 Door

33 72186193 打印机组件 Printer Assembly,2" Label

34 182872 立杆固定座 Sheet Metal,support,Tower to base

35 72184997 AMI-22 传感器 Loadcell Assembly,AMI-22 for 6/15kg

72184996 AMI-40 传感器 Loadcell Assembly,AMI-40 for 15/30kg

1

1

1

1

1

1

2

1

1

1

1

1

2

1

1

1

1

1

2

1

104

72186985 AMI-11 传感器 Loadcell Assembly,AMI-11 for 3/6kg

72186878 AMI-40 传感器 Loadcell Assembly,AMI-40 for 30kg 6000e

72186875 AMI-40 传感器 Loadcell Assembly,AMI-22 for 12kg 6000e

36 72186402 导轨座 Printer Rail

37 72185419 垫 块 Loadcell spacer

38 72185423 钣金托架 Spider support

39 182874 立杆盖板 B Plastic cover B,Front,Tower,bC/bPro-T2

40 180976 立杆 Tower,bC/bPro-T2

41 180873 立杆盖板 A Plastic cover A,Rear,Tower,bC/bPro-T2

42 180946 压 板 B Sheet Metal,support B,Display

43 180954 显示盖锁紧件 Sheet Metal,support, disp to Tower

44 180945 压 板 A Sheet Metal,support A,display

45 155637 显示屏 Display Assembly,segment,CHN

72189191 显示屏 Display Assembly,segment,EURO

170120 显示屏 Display Assembly,segment,ENG

72202239 显示屏 Display Assembly,240X240

46 180944 显示外壳 Display Housing

47 72189327 滤光片 Display lens,CHN

183449 滤光片 Display lens,English

72193760 滤光片 Display lens,Euro,bc

48 156439 立杆线束 Harness,Customer display,

49 173248 线束,打印-主板 Harness,Main pcb to printer board

50 72187458 线束,接口-主板 Harness,Main pcb to interface

51 182252 键盘线束 Harness,Main PCB to keyboard

52 171790 显示转接线束 Harness,Segment Disp. convert

173345 显示转接线束 Harness,240x240 Disp. convert

53 72209419 导滑垫板 Slide base

54 72209420 小滑块 Slide space

55 72224370 塑料线卡 Clip

B1 72204992 螺钉 M4X12,GB818-85 SCREW M4X12

B2 119054 铅封头 SEALING HEAD

B3 118549 铅封螺钉 SEALING SCREW

B4 72189609 螺钉 M4X8,GB818-85 SCREW M4X8

B5 72201470 螺钉 M4X6 SCREW M4X6

B6 102504 螺钉,M6X20,GB70-85 SCREW M6X20

B7 72204993 紧定螺钉,M5X16,GB79-85 SLOT SCREW

B8 72194324 方螺母,M4 NUT M4

B9 72201474 自攻螺钉,M2.9X10,GB845 SCREW

B10 72201466 螺钉,M3X6,GB818 SCREW

B11 102661 弹簧垫圈 SPRING WASHERS

105

2

2

2

2

1

1

2

2

2

2

1

1

1

1

1

1

1

1

1

1

1

4

4

2

6

1

2

14

24

14

4

1

1

1

1

1

1

1

1

9

B12 72201469 螺钉,M4X14,GB819 SCREW

B13 142884 紧定螺钉,M3X8,GB79-85 SLOT SCREW

B14 72201468 螺钉,M3X6,GB819 SCREW

B15 133022 齿垫 ¢4 WASHERS

6

4

2

2

106

72187321 bPro-U2

72187321 bPro-U2

Item P/N Description

1 180945 压 板 A Sheet Metal,support A,display

107

Qty

1

2 155637 显示屏 Display Assembly,segment,CHN

72189191 显示屏 Display Assembly,segment,EURO

170120 显示屏 Display Assembly,segment,ENG

72202239 显示屏 Display Assembly,240X240

3 180944 显示外壳 Display Housing

4 72189327 滤光片 Display lens,CHN

183449 滤光片 Display lens,English

72193760 滤光片 Display lens,Euro,bc

5 180977 立杆 B Tower B bPro/bC-U2

6 173476 键盘转接板 PCB Assembly,keyboard convert

7 72183679 键盘支架 Sheet Metal,support,keyboard

8 72186085 上键盘盖 Keyboard Housing,Top Cover

9 72186578 银浆电路 Keyboard,Membrane layer

10 72186679 键盘挂钉 Keyboard, Pin

11 72186581 键盘,白色橡胶触点层,bPro-U2 Keyboard, Rubber button padding,bPro U2 1

12 72193809 键盘,操作面板 bPro-U2 英文 Keyboard, Operation layer,bPro U2 ENG 1

13 72186580 键盘,透明硅胶按压层 Keyboard,Touch pad,Silicon,bPro U2

14 102326 水泡 Leveling Bubble

1

1

1

1

1

2

15 124041 中心橡胶垫 Cap,Spider,Center

16 180974 托 架 Spider

17 122206 纸铅封 Sealing Sticker,EU

1

1

1

2

2

2

2

2

2

2

2

1

1

18 72192054 铅封盖板 Sealing Cover

19 154555 角垫 Cap,Spider,,Corner

20 180943 上盖 Main Housing Cover

21 72185423 钣金托架 Spider support

22 174032 A/D 板 PCB Assembly,AD board

23 180951 开关固定板 Sheet Metal,support ,Power Switch

24 72187456 线束,电源开关 Harness,AC power Switch

25 72187455 电源线束 Harness,AC Power Socket

26 72186386 开关电源 24v Switch Power Supply,24v,2.7A

72186387 开关电源 24v Switch Power Supply,24v,4.2A

27 72186444 接口固定板 Sheet Metal,Support,interface

28 173307 接口板 PCB Assembly ,interface

29 183358 基座盖板 Sheet Metal,base cover

30 169795 主板 PCB Assembly ,Main board,standard

72186557 主板 PCB Assembly ,Main board,Premium

31 72188140 秤 脚 Foot,short,right

32 72184997 AMI-22 传感器 Loadcell Assembly,AMI-22

72184996 AMI-40 传感器 Loadcell Assembly,AMI-40

72186985 AMI-11 传感器 Loadcell Assembly,AMI-11

72186878 AMI-40 传感器 Loadcell Assembly,AMI-40 30kg 6000e

1

2

1

1

1

1

1

1

1

1

1

1

1

1

4

1

1

1

1

108

72186875 AMI-40 传感器 Loadcell Assembly,AMI-22 12kg 6000e

33 180973 基座 Aluminum Base Casting

34 72191369 基座小盖板 A COVER A,Base

35 72191370 基座小盖板 B COVER B,Base

36 180975 导轨 Printer Rail Slider

37 72186193 打印机组件 Printer Assembly,2" Label

38 72185419 垫 块 Loadcell spacer

39 173251 立杆线束,点阵 Harness,240x240 Display

72191008 线束,IIC(欧元段码) Harness,segment Display

40 182872 立杆固定座 Sheet Metal,support,Towertobase

41 72186088 立杆盖板 D Plastic Cover,Front,UpperKB

42 72186087 立杆盖板 C Plastic Cover,Rear,UpperKB

43 72183678 显示支架 Sheet Metal,support,display

44 72186402 导轨座 Printer Rail

45 72186086 上键盘座 Keyboard Housing,Base

46 72187458 线束,接口-主板 Harness,Main pcb to interface

47 180947 打印机侧门 Door

48 173248 线束,打印-主板 Harness,Main pcb to printer

49 173596 直流线束 Harness,DC Power

50 167391 秤脚 FOOT,Long,left

51 183021 秤盘组件 Platter

52 182252 键盘线束 Harness,Main PCB to keyboard

53 171790 显示转接线束 Harness,Segment Disp. convert

173345 显示转接线束 Harness,240x240 Disp. convert

54 180952 上盖活动盖板 Label Roll Housing

55 72224370

56 72187457 线束, 键盘转接 Keyboard convert

57 72209419 导滑垫板 Slide base

58 72209420 小滑块 Slide space

59 72224168 显示连接支架,bPro display support metal 1

B1 72201466 螺钉,M3X6,GB818 SCREW 18

1

1

1

1

1

1

1

1

B2 72201474 自攻螺钉,M2.9X6.5,GB845 SCREW

B3 72204992 螺钉 M4X12,GB818-85 SCREW M4X12

6

9

B4 72204993 紧定螺钉,M5X16,GB79-85 SLOT SCREW 4

B5 72201468 螺钉,M3X10,GB819 SCREW 2

B6 72189609 螺钉 M4X8,GB818-85 SCREW M4X8

B7 72201473 螺钉,M6X20,GB70-85 SCREW M6X20

B8 72194324 螺母,M4 NUT M4

B9 72201464 螺钉 M2X6,GB67 SCREW M2X6

B10 72201470 带齿垫螺钉 M4X5 SCREW M4X5

B11 150684 开口挡圈 3.2 CIRCLIPS 3.2

21

2

9

4

2

2

1

1

1

1

1

1

1

1

1

2

1

1

1

1

1

1

1

1

1

1

1

109

B12 102661 弹簧垫圈 SPRING WASHERS

B13 72201469 螺钉,M4X14, GB819 SCREW

4

3

110

METTLER TOLEDO

Scales & Systems

1900 Polaris Parkway

Columbus, Ohio 43240

P/N: 72186164

(3/09).02

METTLER TOLEDO

® is a registered trademark of Mettler-Toledo, Inc.

©

2000 Mettler-Toledo, Inc.

Printed in China

72186164

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement

Table of contents