microbeau SPEKTRA FLUX S User Manual
PDF
Document
Advertisement
Advertisement
Wireless Cartridge Machine USER MANUAL 2019 INDEX Safety Notice 3 Machine Overview 4 The Grip 5 The Body 6 The PowerBolt 7 Detaching PowerBolt 8 USB-C Connection 9 Connecting your Machine 10 Adjusting Needle Depth 11 Additional Information 12 Troubleshooting 13 USER MANUAL SAFETY NOTICE CLASS III SYMBOL A Class III appliance is designed to be supplied from a separated/safety extra-low voltage (SELV) power source. The voltage from a SELV supply is low enough that under normal conditions a person can safely come into contact with it, without risk of electrical shock. The extra safety features built into Class I and Class II appliances are therefore not required. For medical devices, compliance with Class III is not considered sufficient protection, and further more-stringent regulations apply to such equipment. TECHNICAL DATA Operating Voltage: 5 - 12 V DC Current: .3 A Stitch Frequency: 25 -160 Hz Stroke: 3 mm Connection: USB-C Drive: Brushless 9 Watt motor Operating Mode: Continious operation Ambient Temperature: +10 to +35 °C Relative Humidity: 30 to 75% Dimensions (Ø X L): 35 x 125 mm Weight: Approx. 170 g BARRIER PROTECTING YOUR MACHINE Although the grip is autoclavable, we strongly suggest the use of barrier products to protect your machine. For a visual demonstration of many barrier protection methods, please visit our YouTube channel Microbeau. “This machine is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge” 3 USER MANUAL MACHINE OVERVIEW USB-C connectivity Dynamic power path management USB-C Li-ion battery with capacity and voltage LED indicator. Bluetooth enabled: Pair with Darklab app. Detachable battery: instantly switch to auxiliary battery (sold separately) 9 Watt brushless motor Ratcheted, adjustable needle depth system THE SPEKTRA FLUX S Direct Drive: 3 MM stroke Unleash your Power The first wireless pen-style Ergonomic autoclavable grip design for tattooing machine featuring a detachable battery, complete Bluetooth connectivity, and a whole new level of freedom. 4 USER MANUAL THE GRIP Spektra Flux S Grip Autoclavable Ergonomic Grip Design Compatible with most membrane needle cartridges on the market THE GRIP The Flux S grip allows artists options will be available soon. anodized grip is safe to be ratcheting control over needle The Grip is crafted from a solid sterilized under steam, in an depth. The standard Grip has a rod of 6061 T6 aircraft-grade autoclave or sprayed with cold diameter of 28mm. Other grip aluminum. This polished and sanitation solutions. 5 USER MANUAL THE BODY Spektra Flux S Body Ratcheted Disk System Flux S Body THE BODY Friction Stabilizing O-Rings The Body is the core of the machine. Constructed from a solid rod of 6061 T6 aircraft- grade aluminum, this module should be sanitized by wiping it with cold sterilization solutions only. Caution: Avoid getting fluids into the housing Body Isometric View 6 Body Posterior View USER MANUAL THE POWERBOLT Flux S PowerBolt THE POWERBOLT LED indicator: Solid Color = Whole Value Blinking Color = Half Increment Ex. Solid green indicates 10V Flashing green indicates 10.5V Battery Level Check: Press and hold power button till white. A blinking colored light indicates remaining charge. Note: LED flashes while battery charges. Once < 15% is reached, red light will blink alternately with voltage. LED Indicator Voltage Up 100 - 98% 97 - 60% 59 - 40% Power Button Voltage Down 39 - 15% 14 - 0% Working with modes: Modes work by pressing and releasing the power button. Bluetooth – Hold the power button until a blue light appears and immediately release the power button. A blue blinking light indicates pairing mode is available for 60 seconds. To deactivate Bluetooth, hold the power button and release when the yellow light flashes. USB-C Travel Mode (Shutdown) – Press and hold the power button until the red light flashes. This mode is for when you want to avoid unnecessary discharge and / or comply with travel laws. To reactivate, connect / disconnect to a USB-C port. Reset (Factory Settings) – Should you experience abnormal behavior, hold the power button and the voltage up button at the same time, then quickly release. 7 PowerBolt Top/ Bottom Views USER MANUAL DETACHING THE POWERBOLT Twist the PowerBolt as shown and remove. Get a firm grip and turn the body as shown with the Grip. DETACHING THE POWERBOLT To detach your PowerBolt, To attach the PowerBolt, push align correctly. Avoid contact ensure you have a firm grip on in while twisting clockwise. with the PowerBolt leads while the Body and Grip. Turn the Ensure lock mechanism moves recharging or servicing. PowerBolt counter clockwise freely. PowerBolt must sit and pull out. correctly to ensure power leads 8 USER MANUAL USB-C CONNECTION Fast charging speed: Up to 1.5 A USB-C Connector USB-C CONNECTION This connecting terminal is compatible with most USB-C cables on the market. We recommend you use the included cable for recharging the PowerBolt. USB-C Darklab supplied cord 9 USER MANUAL CONNECTING YOUR MACHINE 1 Plug the USB-C cord into the PowerBolt connector. HOW TO CONNECT YOUR MACHINE Best connection Improper connection Insert the provided USB-C while plugged in. The USB-C cable into the back of the connection is meant only for PowerBolt and connect to a recharging your PowerBolt. Hover or power socket. Make PowerBolt can be recharged sure the cable is properly whether or not it is connected seated and is fully inserted to the Flux S. If connecting to into PowerBolt. The PowerBolt a Hover, the charge speed will is not meant to operate be up to 1.5 A. 10 USER MANUAL ADJUSTING NEEDLE DEPTH Increases needle depth Decreases needle depth ADJUSTING NEEDLE DEPTH To adjust needle depth, hold the machine body and PowerBolt while turning the Grip. A counter clockwise turn decreases depth, while a clockwise turn increases depth (also known as needle hang). Each time you turn the grip you can feel the tactile feedback of the ratcheting mechanism. Each “click” displaces your needle 0.2mm and allows you to set your needle precisely without involuntarily turning while tattooing. Turning the grip as shown increases needle depth. 11 Turning the grip as shown decreases needle depth. USER MANUAL ADDITIONAL INFORMATION VOLTAGE PARAMETERS While voltage is a parameter that will vary from artist to artist, this machine has been tested to operate at a minimum voltage of 5 Volts and a maximum voltage of 12 Volts. Depending on the type of needle configuration or brand you use, feel free to adjust the voltage to obtain the desired performance. ACCEPTED NEEDLES Use only cartridge needles with an internal membrane. This will avoid accidental contamination inside your machine. Fluids such as ink, water or oil will void warranty of the device and may require replacement of internal parts. MAINTENANCE • Flux S is sold pre-lubricated from the factory and does not need internal lubrication. • Prevent any type of external elements from entering inside the machine as they will disrupt the motion of the component and contaminate lubrication. • The grip of the machine is autoclavable. Use only steam autoclaves at temperatures no higher than 270° Fahrenheit or 132.222° Celsius. Add a hint of ointment or PTFE grease around internal opening of grip or on stabilizing friction O-rings for optimal functionality after autoclaving. Refer to page 5 for additional information. • Machine Body and PowerBolt can be sanitized from the outside with cold sterilization products. • Never spray the surface directly to prevent fluids from entering the machine. Always use pads or disposable paper towels to apply sterilization products. • DO NOT DISASSEMBLE MACHINE. WARRANTY • All the housing components (Grip, Machine Body and PowerBolt) are covered by a lifetime warranty. • Internal parts are subject to wear and the motor itself will be covered by a 1 year warranty from the date of purchase. • Motor warranty is void if motor shows signs of being dropped, of internal fluids entering the motor, and/or IF motor shows signs of being tampered with in any way. 12 USER MANUAL ADDITIONAL INFORMATION HANDY TIPS The following tips will help you get the most out of your Spektra Flux S and avoid potential issues: • Always secure your machine. Dropping the machine can cause damage to the magnets, bearings and brushes of the motor. • Use only cartridges with membranes to avoid contamination. • Rinse your needle frequently to avoid pigment drying up and slowing down your cartridges. When rinsing your needle, ensure to dip only the tip of the cartridge to avoid back flow of fluids. • Inspect your needles prior to use. • Avoid scratching the surface of the embodiments. • Use only FDA-approved cold sterilization solutions for disinfection. • Do not lubricate machine unless instructed otherwise. • Store your machine in a secure place. • Before first use, charge battery for a minimum of 3 hours. TROUBLESHOOTING 1.- Machine manufacturer Microbeau Int.: 1771 NW 79th Avenue, Doral, Florida 33126 2.- Servicing your machine Just like any mechanical device subject to use, Microbeau strongly suggests that you service your product at least once a year to ensure that a proper diagnosis of all working parts is conducted. This ensures the optimal condition of all working parts including internal machine clean up and fresh lubrication. Routine servicing will ensure that your machine remains functioning like the very first day. Service is subject to fees. 3.- Warning Disconnect machine from any power before making any adjustments. For service inquiries, please contact [email protected]. For additional tips and tutorials, please visit Microbeau’s YouTube channel. 13 ">

Download
Just a friendly reminder. You can view the document right here. But most importantly, our AI has already read it. It can explain complex things in simple terms, answer your questions in any language, and help you quickly navigate even the longest or most compilcated documents.
Advertisement