Advertisement
Advertisement
User’s
Manual
Models SR10001/SR10002/SR10003/SR10004/
SR10006
SR10000 Recorder
Yokogawa Electric Corporation
IM 04P03B01-01E
1st Edition
Foreword
Notes
Trademarks
Revisions
Thank you for purchasing the YOKOGAWA SR10000 Recorder.
This user’s manual explains how to use the SR10000 recorder excluding the communication functions. To ensure correct use, please read this manual thoroughly before operation.
The following three manuals including this manual are available for the SR10000
Recorder.
• Paper Manual
Manual Title
SR10000 Recorder
Operation Guide
Manual No.
Description
IM 04P03B01-02E Explains concisely the operations of the
SR10000 Recorder. It is also provided in the
CD-ROM.
• Electronic Manuals Provided on the Accompanying CD-ROM
Manual Title
SR10000 Recorder
Operation Guide
SR10000 Recorder
User’s Manual
SR10000
Communication Interface
User’s Manual
Manual No.
Description
IM 04P03B01-02E Explains concisely the operations of the
SR10000 Recorder. This is the electronic version of the paper manual.
IM 04P03B01-01E This manual.
IM 04P03B01-17E Explains the communication functions of the
SR10000 Recorder using Ethernet interface and the RS-422A/485 communication interface.
• The contents of this manual are subject to change without prior notice as a result of continuing improvements to the instrument’s performance and functions.
• Every effort has been made in the preparation of this manual to ensure the accuracy of its contents. However, should you have any questions or find any errors, please contact your nearest YOKOGAWA dealer as listed on the back cover of this manual.
• Copying or reproducing all or any part of the contents of this manual without the permission of Yokogawa Electric Corporation is strictly prohibited.
• The TCP/IP software of this product and the document concerning the TCP/IP software have been developed/created by YOKOGAWA based on the BSD
Networking Software, Release 1 that has been licensed from the University of
California.
• All the brands or names of Yokogawa Electric’s products used in this manual are either trademarks or registered trademarks of Yokogawa Electric Corporation.
• Microsoft, MS-DOS, Windows, Windows NT, and Windows XP are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.
• Adobe, Acrobat, and PostScript are trademarks of Adobe Systems incorporated.
• For purposes of this manual, the TM and ® symbols do not accompany their respective trademark names or registered trademark names.
• Company and product names that appear in this manual are trademarks or registered trademarks of their respective holders.
1st Edition February 2006
1st Edition: February 2006 (YK)
All Rights Reserved, Copyright © 2006 Yokogawa Electric Corporation
IM 04P03B01-01E i
ii
How to Use This Manual
Read the Operation Guide first to familiarize yourself with the basic operation, and
then read this manual. For a description of the communication function, see the
SR10000 Communication Interface User's Manual (IM 04P03B01-17E)
.
This user's manual consists of the following sections.
Chapter Title and Description
1 Functional Description
Describes the functions of the SR10000 Recorder.
2
3
Frequently Used Setup Operations (Setting Mode)
Describes how to change the input range, alarms, chart speed, etc.
Setup Operations for Convenient Functions (Setting Mode)
Describes the setup operations for convenient functions such as how to assign tags to channels and how to set message strings that are to be printed.
4
5
6
7
Setup Operations for Changing/Adding Functions (Basic Setting Mode)
Describes the setup operations for changing or adding functions such as setting the recorder to detect sensor burnouts and changing the contents that are printed on the chart paper.
Troubleshooting
Describes error message and troubleshooting measures of the SR10000 Recorder.
Maintenance
Describes periodic inspection, calibration, and pen adjustment/printer carriage adjustment.
Specifications
Gives the specifications of the SR10000 Recorder.
Index
Note
• This user’s manual covers information regarding the recorders with English as the printout font (suffix code “2”).
IM 04P03B01-01E
How to Use This Manual
Conventions Used in This Manual
Unit
K ........ Denotes 1024. Example: 768 KB (file size) k ........ Denotes 1000.
Safety Markings
The following markings are used in this manual.
Improper handling or use can lead to injury to the user or damage to the instrument.
This symbol appears on the instrument to indicate that the user must refer to the user’s manual for special instructions. The same symbol appears in the corresponding place in the user’s manual to identify those instructions. In the manual, the symbol is used in conjunction with the word “WARNING” or “CAUTION.”
WARNING
Calls attention to actions or conditions that could cause serious or fatal injury to the user, and precautions that can be taken to prevent such occurrences.
1
2
3
4
5
6
CAUTION
Note
Calls attentions to actions or conditions that could cause light injury to the user or damage to the instrument or user’s data, and precautions that can be taken to prevent such occurrences.
Calls attention to information that is important for proper operation of the instrument.
Subheadings
On pages that describe the operating procedures in Chapter 2 through 4 and 6, the following symbols are used to distinguish the procedures from their explanations.
Procedure
Follow the numbered steps. All procedures are written with inexperienced users in mind; depending on the operation, not all steps need to be taken.
Explanation
This subsection describes the setting parameters and the limitations on the procedures. It does not give a detailed explanation of the function. For details on the function, see chapter 1.
7
Index
IM 04P03B01-01E iii
Contents
iv
Chapter 1 Functional Description
Chapter 2 Frequently Used Setup Operations (Setting Mode)
Chapter 3 Setup Operations for Convenient Functions (Setting Mode)
Turning Trend Recording (Dot Model) and Periodic Printout ON/OFF for Each Channel 3-6
Setting the Secondary Chart Speed (Remote Control Function, /R1) ............................. 3-9
Setting the Date/Time for Switching between Standard Time and DST ......................... 3-13
Chapter 4 Setup Operations for Changing/Adding Functions (Basic Setting
Mode)
Recording by Compensating for the Pen Offset along the Time Axis (Pen Model) .......... 4-7
IM 04P03B01-01E
Contents
Assigning Functions to the Remote Control Input Terminals (/R1 Option) ..................... 4-24
Chapter 5 Troubleshooting
Chapter 6 Maintenance
Chapter 7 Specifications
Index
1
2
3
4
5
6
7
Index
IM 04P03B01-01E v
Chapter 1 Functional Description
1.1
Measuring Input Section
Input Section
Number of Measurement Channels and Scan Interval
The recorder samples the input signals on the measurement channels at the scan interval to obtain the measured values.
Model
1-pen model
2-pen model
3-pen model
4-pen model
Dot model
Number of Channels
3
4
1
2
6
Scan Interval
125 ms
125 ms
125 ms
125 ms
1 s
(However, the scan interval is 2.5 s when the integration time of the A/D converter is 100 ms.)
Input Type, Measurable Range, and Computation
The recorder can measure the following types of inputs.
Input Type Measurable Range
DC voltage
1-5V
DC voltage in the range of ±20 mV to ± 50 V
See “1-5V” below.
Thermocouple Temperature range corresponding to each type: R, S, B, K, E, J, T, N, W, L, U, and WRe
RTD Temperature range corresponding to each type: Pt100Ω and JPt100Ω
ON/OFF input Contact input: Open contact is OFF (0). Closed contact is ON (1).
Voltage input: Less than 2.4 V is OFF (0). Greater than or equal to 2.4 V is ON (1)
• 1-5V
1-5V is scaled to values in the appropriate unit to be used as measured values. Also, the low-cut function (input less than 0% is fixed to 0 (scale left value)) can be used.
• Current Input
A shunt resistor is attached to the input terminal. The current signal is converted to a voltage signal and measured. The measurable range is the range equivalent to the
“DC voltage” range indicated above after converting the current to the voltage signal.
Note
Three types of shunt resistors (250 Ω, 100 Ω, and 10 Ω) are available for current input (See
“Optional Accessories (Sold Separately)” in the Operation Guide .) For example, a 250-Ω shunt resistor is used to convert the signal to the range of 1 to 5 V for 4 to 20 mA input.
• Range Type, Measurable Range, and Recording Span
Various “range type” are available for the different types of inputs (for example thermocouple R). Each range type has a preset measurable range (0.0 to 1760.0°C for thermocouple R). Measurement can be made by specifying an arbitrary range within the measurable range as the input range
. The measured values in the input range are recorded on the chart paper. The range of measured values that are recorded is called the recording span
.
Measurable range
(Thermocouple R example)
1760.0
°
C
Input range or recording span
1500.0
°
C (rightmost value of span)
300.0
°
C (leftmost value of span)
0.0
°
C
For the procedure to set the functions, see section 1.6, “Function Setup Guide.”
1-1
IM 04P03B01-01E
1
1.1 Measuring Input Section
• Delta Computation
The value obtained by subtracting the measured value of another channel (called the reference channel ) from the input value of the channel set to delta computation is used as the measured value of that channel. The reference channel must be assigned to a channel whose channel number is less than that of the channel on which delta computation is specified. The channel on which delta computation is specified is automatically set to the same range type as the reference channel.
Channel set to delta computation
+
Input value
Measured value
–
Measured value on the reference channel
DC voltage
Note
A channel whose input type is set to DC voltage, TC, or RTD can be designated as a reference channel. However, channels set to scaling or square root computation cannot be designated.
• Scaling
The input values are scaled to values in the appropriate unit to be used as measured values.
Input value
10 V
Measured value
300.0
°
C
1-2
0 V
−
100.0
°
C
• Square Root Computation
When the input type is DC voltage, the square root of the input value is calculated, the result is scaled to a value in the appropriate unit, and used as the measured value of the channel. Also, the low-cut function (input less than a given measured value is fixed to 0 (scale left value)) can be used.
Channel set to square root computation
Input value
√
Scaling
Measured value
Measured value
Result of square root computation
Low-cut value
Note
The square root computation on the recorder uses the following formula.
min
+ F min where V min
(leftmost value of span) < V max
(rightmost value of span)
F min
(leftmost value of scale after scaling) < F max
(rightmost value of scale after
scaling)
V x
is the input voltage and F x
is the scaled value
For the procedure to set the functions, see section 1.6, “Function Setup Guide.”
IM 04P03B01-01E
1.1 Measuring Input Section
• Bias
A given value (bias value) is added to the input value and used as the measured value of that channel.
Biased channel
Input value
Measured value
+
Bias value
• Calibration Correction (/CC1 Option)
Corrects the measured value of each channel using segment linearizer approximation and makes the resultant value the measured value of the channel. You can set arbitrary correction values for 2 to 16 points of arbitrary measured values. Linear approximation is used between two segment points. Correction values can be assigned using revise values or absolute values.
Scale value
B5
Measured value
A5
A4
Correction value
Correction using revise values
Measured value = A
Correction value = B – A
B3
B4
Correction using absolute values
Measured value = A
Correction value = B
B2
A1 to A5: Measured value (measured value before correction)
B1 to B5: Correction value (measured value after correction)
A3
B1
A1
A2
Calibration point
Reference Junction Compensation of Thermocouple Input
When measuring the temperature using a thermocouple, the reference junction compensation on the recorder can be used. When using external reference junction compensation, you can set the reference voltage. The reference junction compensation can be set for each channel.
By default, the recorder is configured to use the internal reference junction compensation function.
Note
When using external reference junction compensation, set an appropriate reference junction compensation voltage. For example, if the reference junction temperature of the external reference compensation is T
0
°C, set the reference compensation junction voltage to the thermoelectromotive force of the 0°C reference of T
0
°C.
Example when using external reference junction compensation
Recorder
External reference junction compensation
(Hold the contact point of the thermocouple
Copper wire and copper wire at T
0
°
C)
Thermocouple
1
IM 04P03B01-01E
For the procedure to set the functions, see section 1.6, “Function Setup Guide.”
1-3
1.1 Measuring Input Section
Burnout Detection of Thermocouples
This function makes the recording go off the scale to the right or left when the thermocouple burns out while measuring temperature with a thermocouple. This function can also be used on 1-5V. The burnout detection function can be set for each channel.
By default, this function is disabled.
Note
For 1-5V, a burnout occurs when the input value is less than or equal to 0.2 V.
Noise Elimination from Input Signals
Filter and Moving Average
This function used to suppress the effects of noise that is riding on the signal. The pen model and dot model are equipped with a filter function and a moving average function, respectively. The function can be set for each measurement channel. However, it does not operate on channels set to ON/OFF input.
• Filter (Pen Model)
The filter is a low-pass filter. The time constant can be set to 2 s, 5 s, or 10 s.
Filter result (output for a step input)
Input signal
63.2% of the output value
Output response curve
(when using the filter)
2, 5, 10 s (time constant, the time it takes to reach 63.2% of the output value)
• Moving Average (Dot Model)
The average value of the m most recent values acquired at the scan interval is used as the measured value of the channel. The number of moving-averaged data points
(m) can be set in the range 2 to 16. The figure below shows an example indicating the operation of the buffer for the moving average computation when the number of moving averaged data points is set to 5.
Buffer data for the nth sampling time
Buffer data for the n+1th sampling time
Most recent data
Buffer data for the n+2th sampling time
Most recent data
Moving average
3
4
1
2
5
10.0 mV
5.0 mV
0.0 mV
–5.0 mV
–10.0 mV
0.0 mV
Deleted
15.0 mV
10.0 mV
5.0 mV
0.0 mV
–5.0 mV
5.0 mV
Deleted
10.0 mV
15.0 mV
10.0 mV
5.0 mV
0.0 mV
8.0 mV
1-4
For the procedure to set the functions, see section 1.6, “Function Setup Guide.”
IM 04P03B01-01E
1.1 Measuring Input Section
Integration Time of the A/D Converter
The recorder uses an A/D converter to convert the sampled analog signal to a digital signal. By setting the integration time of the A/D converter to match the time period corresponding to one cycle of the power supply or an integer multiple of one cycle, the power supply frequency noise can be effectively suppressed.
The integration time of the A/D converter is selected according to the model from the table below.
Model
Pen model
Dot model
Integration Time of the A/D Converter
Select 16.7 ms (60 Hz), 20 ms (50 Hz), or Auto
Select 16.7 ms (60 Hz), 20 ms (50 Hz), 100 ms or Auto
• If Auto is selected, the recorder detects the power supply frequency and automatically selects 16.7 ms or 20 ms. However, if the 24-VDC power supply is being used on a recorder with the 24-VDC/AC power supply (/P1 option), the integration time is fixed to
20 ms.
• Because 100 ms is an integer multiple of 16.7 ms and 20 ms, this setting can be used to suppress the power frequency noise for either frequency, 50 Hz or 60 Hz.
• The scan interval on the dot model is 1 s when the integration time is set to 16.7 ms or
20 ms and 2.5 s when the integration time is set to 100 ms.
1
IM 04P03B01-01E
For the procedure to set the functions, see section 1.6, “Function Setup Guide.”
1-5
1-6
1.2
Alarms
This function generates an alarm when the measured data meets a certain condition.
The alarm status is displayed on the screen while recording the alarm occurrence/ release on the chart paper.
Also, alarm output relays can be used to output contact signals when alarms occur (/A1,
/A2, and /A3 options).
Alarm Types
Number of Alarm Point Marks
Up to four alarms can be set for each channel.
Alarm Conditions
The following four conditions are available: The alphanumeric character or symbol inside the parentheses is used on the recorder to denote each alarm.
• High Limit Alarm (H/ )
An alarm occurs when the input value exceeds the alarm value.
• Low Limit Alarm (L/ )
An alarm occurs when the input value falls below the alarm value.
High limit alarm
Alarm occurrence
Alarm value
Low limit alarm
Measured value
Alarm release
Alarm release
Measured value Alarm occurrence
Alarm value
• Difference High Limit Alarm (h/ )*
An alarm occurs when the difference in the input values of two channels is greater than or equal to the specified value.
• Difference Low Limit Alarm (l/ )*
An alarm occurs when the difference in the input values of two channels is less than or equal to the specified value.
* Can be specified on channels set to delta computation.
Alarm Hysteresis
Hysteresis can be specified to the values for activating and releasing the alarm. The hysteresis applies only to high limit alarm (H) and low limit alarm (L). The hysteresis width can be set in the range of 0.0% (OFF) to 1.0% of the recording span in 0.1 steps.
The setting applies to all high limit alarms and low limit alarms. By default, the hysteresis width is set to 0.5%.
High limit alarm
Alarm occurrence
Alarm value
Measured value
Alarm release
Low limit alarm
Measured value
Alarm release
Hysteresis
(1% or less)
Alarm value
Alarm occurrence
For the procedure to set the functions, see section 1.6, “Function Setup Guide.”
IM 04P03B01-01E
1.2 Alarms
Alarm Indication
When an alarm occurs, the ALM indicator in the status display section illuminates, and the 2 nd
digit of the LED shows the alarm status for each channel. When the alarm clears, the indicator and the LED turn OFF.
Alarm Recording
The alarm occurrence/release can be recorded on the chart paper. See section 1.3.
Alarm Output Relay (/A1, /A2, and /A3 Options)
Contact signals can be generated from alarm output relays when alarms occur. The number of output relays is 2 (/A1), 4 (/A2), or 6 (/A3). The alarm output relays are denoted as I01 to I06 on the recorder.
The following functions can be assigned to the alarm output relay.
Diagnosis Output
The diagnosis output can be assigned to alarm output relay I01.
The relay is activated when there is an error in the plotter operation on the pen model, when a burnout is detected, or when there is an error in the A/D converter. Output relay
I01 is normally energized and de-energizes when an error is detected (de-energized operation).
Note
If diagnosis output is enabled, I01 becomes a relay dedicated to diagnosis output.
Energized/De-energized Operation of Alarm Output Relays
You can select whether the alarm output relay is energized or de-energized when an alarm occurs. If de-energized is selected, the status of the alarm output relay when an alarm occurs is the same as the status that results when the power is shut down. The setting applies to all alarm output relays.
The default setting is energized.
1
Energize
NO C NC NO C NC NO C NC
De-energize
NO C NC NO C NC NO C NC
When power is turned OFF
When an alarm is not occurring
(During normal operation)
When an alarm is occurring
(During a malfunction)
NO : Normally Opened, C : Common, NC : Normally Closed
Note
If diagnosis output is enabled, I01 is fixed to de-energized operation.
Alarm Output Relay Operation
When the output destination of multiple alarms is assigned to a single alarm output relay, the relay is activated when any of the assigned alarms is occurring (OR operation).
IM 04P03B01-01E
For the procedure to set the functions, see section 1.6, “Function Setup Guide.”
1-7
1.3
Recording
The recorder is capable of recording the measured values with pens or dots (trend recording) as well as various other types of information.
Trend Recording
The measured values are printed within a width of 100 mm.
Recording Method (Pen Model)
• The measured value is updated every scan interval and continuously recorded.
• The recording colors in order from channel 1 are red, green, blue, and violet.
Recording Method (Dot Model)
• The most recent measured value is recorded with a dot every dot printing interval.
The dot printing interval is in the range of 10 s to 90 s. There are two recording methods from which you can select. One method automatically adjusts the dot printing interval according to the chart speed so that the dots do not overlap. The other method records at the fastest dot printing interval at all times.
• The recording colors in order from channel 1 are purple, red, green, blue, brown, and black. The recording color of each channel can be changed among these six colors.
• For each channel, trend recording can be enabled or disabled.
Chart Speed
On the pen model, the chart speed can be selected from 40 settings in the range of 10 to
12000 mm/h.
On the dot model, the chart speed can be selected from 28 settings in the range of 10 to
1500 mm/h.
The default setting is 20 mm/h.
Zone Recording
A recording zone is assigned to each channel.
1-8
Zone 1 Zone 2 Zone 3
For the procedure to set the functions, see section 1.6, “Function Setup Guide.”
IM 04P03B01-01E
1.3 Recording
Partial Expanded Recording
This function expands a section of the recording range. By default, partial expanded recording is disabled.
1
Compressed Expanded
Pen Offset Compensation (Pen Model)
This function compensates for the pen offset (phase difference) along the time axis.
On 2-pen, 3-pen, and 4-pen recorders, there are offsets along the time axis (phase difference) between the pens. This offset is corrected when pen offset compensation is used.
Same time
Below is an explanation for the 2-pen model.
The recording of these two pens are offset by an amount of phase P. If pen offset compensation is enabled, the measured values of pen 1 are stored in the memory, and recorded when the chart paper is fed by an amount corresponding to P.
Reference pen (pen 2)
Pen 1
Recorder front panel
P
Chart paper
Chart feeding direction
By default, this function is disabled.
IM 04P03B01-01E
For the procedure to set the functions, see section 1.6, “Function Setup Guide.”
1-9
1.3 Recording
Printout
The figure below is used to explain the printout contents. The actual printout and font are different from those illustrated in the figure. The printout positions are also slightly different.
Printout Example on the Pen Model
Manual printout
Jan.31.05 15:00
1 223.5mg/cm
3
3 H 591.6˚C
2 437.2
4d
µS/cm
−0.222V
New chart speed printout
50mm/h 14:55
Periodic printout
Time tick cancel mark
Jan.31.05!
13:50*
Pen offset compensation mark
1 218.7mg/cm
3
2 390.6
µS/cm
3 H 598.4˚C
4 d
−0.222V
Scale
1CH mg/cm
3
RED
Delta computation
50mm/h_
Buffer overflow mark
Time tick
Recording color
Alarm printout
1H3*10:09
1H3 10:05
Message printout
09:52*START#205 ABCDEF
Recording start printout
08:00 25mm/h
Time tick
The time ticks are marks that indicate the positions of the date/time on the chart paper.
Time tick cancel mark
An exclamation point (!) is printed when the periodic printout time tick was not printed at the correct position.
1-10
For the procedure to set the functions, see section 1.6, “Function Setup Guide.”
IM 04P03B01-01E
IM 04P03B01-01E
1.3 Recording
Printout Example on the Dot Model
Manual printout
Jan.31.05 16:00
1 223.5mg/cm
3 H 591.6˚C
3
2 437.2
µS/cm
4d
−0.222V
5
−0.665V 6
New chart speed printout
_50mm/h 14:55
Periodic printout
Jan.31.05
13:50
1 218.7mg/cm
3
2 390.6
µS/cm
3 H 598.4˚C
4 d
−0.222V
5
−0.995V
6 L
−0.448V
Time tick
Scale
1CH mg/cm
3
Delta computation
50mm/h_
Alarm
Buffer overflow mark
Time tick
Alarm printout
1H3*10:09
1H3 10:05
Channel printout
Message printout
09:52*START#205 ABCDEF
Recording start printout
_08:00 25mm/h
Time tick
Channel Printout (Dot Model Only)
Prints the channel No. or tag by the trend recording. The channel No. or tag is printed every approximately 25 mm on the chart paper. The channel printout can be enabled or disabled. By default, the channel printout is enabled.
Printout/Display Format of the Date.
The printout/display format of the date can be selected from the list below.
Selectable
Settings
Type Printout Format
Example
Year/Month/Day
Month/Day/Year
2006/03/31
03/31/2006
Day/Month/Year 31/03/2006
Day.Month.Year
31.03.2006
Month.Day.Year
Mar.31.2006
Display Format Notes
Example
Default value 06 03 31
03 31 06
31 03 06
31 03 06
03 31 06
Printout Format of the Time
The printout format of the time can be selected from the list below.
Selectable
Settings
Type
Hour:Minute
Hour:Minute:Second
Month/Day Hour:Minute
Month/Day Hour:Minute:Second
Year/Month/Day Hour:Minute:Second
Printout Format
Example
10:00
10:00:00
03/31 10:00
03/31 10:00:00
2006/03/31 10:00:00
Notes
Default value
*1: The year/month/day format varies depending on the printout/display format of the date.
*2: Can be set to the alarm printout, message printout, recording start printout, and new chart speed printout.
For the procedure to set the functions, see section 1.6, “Function Setup Guide.”
1-11
1
1.3 Recording
1-12
Date
Time
Channel data
Scale
Recording color
Chart speed
Periodic Printout
The contents of the periodic printout vary between the pen model and dot model. Values such as the measured values are printed at the specified interval.
The figure below illustrates the printout contents. The font used in the figure differs from that of the actual printout. The printout positions may also differ from those of the actual printout.
Channel No. or tag
Measured value
Unit
Time tick cancel mark
Offset compensation mark
Mar.31.2006!
15:50*
TAG-001 1.000V
2 -1.000V
3 H-2.1050UNIT03
4 d 2.000V
0.000 2.000
TAG-001
RED
50mm/h_
Time tick
Alarm
• Printout Contents
• Date/Time: The date/time when the periodic printout was executed.
• Time ticks: Marks that indicate the first pen position of the date/time on the chart paper. If the time tick is not printed in the correct position, the pen model prints a time tick cancel mark (!), and the dot model does not print the time tick.
• Offset compensation mark: When pen offset is being executed on the pen model, asterisks (∗) are printed.
• Channel data: Prints the channel numbers or tags, measured values
(instantaneous values), and units.
• Alarm status: Prints the alarm that is occurring. Prints the letter “d” on channels set to delta computation. If multiple alarms are occurring, the alarm with the highest precedence is printed.
• Scale:
Alarm printout precedence: (Higher) H, L, h, and l (lower)
Prints the leftmost and rightmost values of the recording span and the channel number or tag for channels that have scale printout specified. The scale is printed for one channel at each periodic printout. The channel whose scale is printed changes in ascending order. The scale of channels that are being zone recorded is printed within the recording range of the zone for 40 mm or greater.
• Recording color (pen model): Prints the recording colors of channels that have scale printout and recording color printout specified.
• Chart speed: The chart speed can be printed.
• For the measured values and alarm status, you can select whether to print them for each channel. For the scale and recording color (pen model), you can select whether to print them.
Prints the letter “d” for channels set to delta computation.
• Interval
The printout interval can be set by specifying the value or set automatically in sync with the chart speed. Printout is not carried out at the following chart speeds.
Pen model: 1800 mm/h or higher
Dot model: 120 mm/h or higher
• Turning ON/OFF the Periodic Printout
Periodic printout can be turn ON/OFF. By default, periodic printout is enabled with the interval synchronized to the chart speed.
For the procedure to set the functions, see section 1.6, “Function Setup Guide.”
IM 04P03B01-01E
IM 04P03B01-01E
1.3 Recording
Alarm Printout
Alarm information is printed when an alarm occurs or releases.
Time of alarm occurrence/release
Indicates that there are alarms that are not printed because the alarm printout buffer is full.
Level number
Alarm type (H: high limit, L: low limit, h: difference high limit, and l: difference low limit)
Channel No. or tag
: Alarm occurrence, : Alarm release
• The print condition can be set to (1) print when alarms occur and release, (2) print only when alarms occur, or (3) do not print.
• Alarms that occur while an alarm printout is in progress are temporarily saved to the buffer memory in a printout-wait condition. Alarms are cleared from the buffer memory when they are printed.
• The number alarms that can be stored in the buffer is 8 and 12 on the pen model and dot model, respectively. Alarms that occur while the buffer is full are not printed. A buffer overflow mark is printed when there are alarms that cannot be printed because the buffer is full.
• The time printout format can be selected.
Manual Printout
Measured values and alarm status can be printed manually using the keys. When manual printout is executed, trend recording stops and restarts when manual printout is complete.
<For the operation procedure, see the Operation Guide .>
Message Printout
Preset messages can be printed on the chart paper using the keys. Five messages, each within 16 characters, can be registered in advance.
• If message printout is executed while another message is being printed, the most recent message is temporarily stored to the buffer memory in a printout-wait condition.
Messages are cleared from the buffer memory when they are printed.
• The number of messages that can be stored in the buffer is 5. If message printout is executed when the buffer is full, the message is not printed. A buffer overflow mark is printed when there are messages that cannot be printed because the buffer is full.
• The time printout format can be selected.
New Chart Speed Printout
• When the chart speed is changed, the time tick (dot model), the date/time of change, and the new chart speed are printed. An asterisk (∗) shows there are messages that cannot be printed.
• The time printout format can be selected.
Recording Start Printout
When recording is started, the time tick (dot model), the time, and the chart speed can be printed. An asterisk (∗) shows there are messages that cannot be printed.
• The recording start printout can be enabled or disabled. By default, the recording start printout is disabled.
• The time printout format can be selected.
For the procedure to set the functions, see section 1.6, “Function Setup Guide.”
1-13
1
1.3 Recording
Setting Printout
List or setup list can be printed. When setting printout is executed, trend recording stops and restarts when the printout is complete.
List printout contains settings such as the input range and alarm for each channel.
Setup list printout contains settings of basic specifications such as the alarm output relay operation and printout method.
• Printout Example of List on the Pen Model
1-14
The printout examples may appear differently from the actual printout as a result of functional improvements made on the recorder after this manual was written.
For the procedure to set the functions, see section 1.6, “Function Setup Guide.”
IM 04P03B01-01E
• Printout Example of List on the Dot Model
1.3 Recording
1
IM 04P03B01-01E
The printout examples may appear differently from the actual printout as a result of functional improvements made on the recorder after this manual was written.
For the procedure to set the functions, see section 1.6, “Function Setup Guide.”
1-15
1-16
1.4
Remote Control Function (/R1 Option)
Specified operations can be carried out by applying remote signals (contact or open collector signals) to the remote control input terminals.
There are five remote control input terminals. An action can be assigned to each terminal.
Assignable Functions
• Recording start/stop
• Remote input signal: Rising edge signifies start; falling edge signifies stop
• Starts/stops recording.
• Applying a rising edge signal when recording is already in progress produces no effect. Applying a falling edge signal when recording is stopped produces no effect.
• Chart Speed Switch
• Remote input signal: Level
• The chart paper is fed at the secondary chart speed while a level signal is applied to the terminal. The secondary chart speed is set in advance.
• Internal Clock Adjustment
• Remote input signal: Trigger
• The internal clock of the recorder is adjusted to the nearest hour depending on the time when the remote signal is applied.
Time When Signal Is Input
00 min 00 s to 01 min 59 s
02 min 00 s to 57 min 59 s
58 min 00 s to 59 min 59 s
Adjustment
Truncates the minutes and seconds.
Example: 10 hours 01 min 50 s becomes 10 hours 00 min 00 s.
The time is not changed.
Rounds up the minutes and seconds.
Example: 10 hours 59 min 50 s becomes 11 hours 00 min 00 s.
• Message 1 Printout to Message 5 Printout
• Remote input signal: Trigger
• Manual Printout
• Remote input signal: Trigger
Remote Signal (Edge, Trigger, and Level)
The above actions are carried out on the rising or falling edge of the remote signal
(edge), the ON signal lasting at least 250 ms (trigger), or the ON/OFF signal (level).
Rising/Falling edge
Rising Falling
Trigger Level
250 ms or more
250 ms or more Operates at the secondary chart speed
For contact inputs, the remote signal rises when the contact switches from open to closed and falls when the contact switches from closed to open. For open collector signals, the remote signal rises when the collector signal (voltage level of the remote control terminal) goes from high to low and falls when the collector signal goes low to high.
For the procedure to set the functions, see section 1.6, “Function Setup Guide.”
IM 04P03B01-01E
1.5
Other Functions
Key Lock
Key lock is a function that prohibits key operations. When key lock is enabled, pressing keys produces no effect. To release the key lock, a password is entered.
Key Lock Items
Each of the following keys can be included or excluded from the key lock function.
1
Customize Menu
The menu can be customized to display only the menus that you use.
• Display only the items that you use on the FUNC key menu.
• Display only the items that you use on the Setting mode menu.
• Lock Basic Setting mode (use a password to enter the mode).
The pen position adjustment (pen model) and dot printing position adjustment (dot model) can be set so that they can be used without the password.
Basic Setting mode Operation mode
Displays only the
FUNC key menu items to be used
Hold down
MENU for 3 s
Setting mode
Displays only the setup menu items to be used
Hold down + for 3 s
Password
No password
Pen and dot printing position adjustment
Font
The characters used in the printout can be set to English, Japanese, German, or French.
The characters that are available vary depending on the selected font.
English: Alphabet, numbers, and symbols
Japanese: Alphabet, numbers, Katakana, and symbols
German: Alphabet (German), numbers, and symbols
French: Alphabet (French), numbers, and symbols
DST
Keys that can be locked
In the case of the FUNC key, each function of the FUNC key can be included or excluded from the key lock function.
FUNC key functions: Manual printout, list printout, setup list printout, message printout, printout buffer clear, pen exchange (pen model), and ribbon cassette exchange (dot model)
If the recorder is used in a region that has DST, time can be switched automatically between DST and standard time by setting the date/time when switching from the standard time to DST and the date/time when switching back from DST to standard time.
When switching from standard time to DST, the clock is set ahead by 1 hour. When switching back from DST to standard time, the clock is set back by 1 hour.
Temperature Unit
The temperature unit can be set to Celsius or Fahrenheit. The setting applies to all channels.
IM 04P03B01-01E
For the procedure to set the functions, see section 1.6, “Function Setup Guide.”
1-17
1.6
Function Setup Guide
This section explains the settings necessary to use various functions of the recorder.
Read the section corresponding to the function you wish to use.
Note
This section contains all the settings related to each item. If the desired setting is the same as the default value, you do not have to set it.
Item
Date/Time setting
DST
Setting initialization
Description
Use CLOCK in Setting mode
Sets the date/time for switching between DST and standard time using
AUX > DST in Setting mode.
Use INIT in Basic Setting mode to initialize the settings of Setting mode and Basic Setting mode to their default values.
Reference
Section
2.5
3.12
4.17
Measuring input functions
Item Description Reference
Section
Input range of each channel
Set RANGE in Setting mode.
1-5V
2.1
• Unit
Use UNIT in setting mode to set the unit after scaling.
• Low-cut
Use PERS. > 1-5V low-cut in Basic Setting mode and select Use or Not.
If Use is selected, turn ON/OFF the low-cut function using RANGE in Setting mode.
If Not is selected, the Low-cut item does not appear in the RANGE setting.
2.3
4.15
2.1
2.3
Scaling
Square Root Computation • Unit
Use UNIT in setting mode to set the unit after scaling.
• Low-cut
Use PERS. > SQRT low-cut in Basic Setting mode and select Use or Not.
If Use is selected, set the low-cut value using RANGE in Setting mode.
If Not is selected, the Low-cut item does not appear in the RANGE setting.
Bias
• Unit
Use UNIT in setting mode to set the unit after scaling.
Use PERS. > BIAS in Basic Setting mode and select Use or Not.
If Use is selected, set the bias value that is added to the input using BIAS in
Setting mode. If Not is selected, the BIAS item does not appear.
2.3
4.15
2.1
4.15
3.10
Calibration Correction (/CC1 option)
Use PERS. > CALIB in Basic Setting mode to select whether to use the calibration 4.15
correction function.
If Use is selected, use CALIB in Basic Setting mode to select revise value or 4.19
absolute value and set the number of correction points.
Use CALIB in Setting mode to set the measured values and correction values.
If Not is selected, the CALIB item of Basic Setting and Setting modes does not appear.
3.11
4.4
RJC of TC input Use RJC in Basic Setting mode to select whether to use the recorder’s
RJC function or an external RJC function.
Burnout detection function of TC input and 1-5V input
Use B_OUT in Basic Setting mode to set the burnout detection function for each channel.
4.3
Filter (pen model) Use FILTR in Basic Setting mode and select Use or Not.
4.11
If Use is selected, set the filter time constant using AUX > FILTR in Setting mode.
3.2
If Not is selected, the AUX > FILTR item does not appear.
Moving average (dot model)
Use M_AVE in Basic Setting mode and select Use or Not.
If Use is selected, set the number of samples of moving average using AUX >
M_AVE in Setting mode.
If Not is selected, the AUX > M_AVE item does not appear.
4.10
3.3
1-18
IM 04P03B01-01E
1.6 Function Setup Guide
Item Description
Integration time of the A/D converter
Use INTG in Basic Setting mode to set the integration time of the A/D converter.
Temperature Unit Select the temperature unit using TEMP in Basic Setting mode.
Reference
Section
4.2
4.23
Alarm functions
Item Description Reference
Section
2.2
Alarms for each channel Use ALARM in Setting mode.
Set a hysteresis on the alarm occurrence/release value of high limit alarm and low limit alarm
Use ALARM > HYS in Basic Setting mode to set the hysteresis to be applied to the high limit alarm and low limit alarm of measurement channels.
4.1
Diagnosis output Use ALARM > DIAG in Basic Setting mode to set the function.
4.1
Change the alarm output relay operation
If ALARM > RELAY in Basic Setting mode set to “DE_EN”, alarm output relay is 4.1
energized during normal operation and de-energized when an alarm occurs.
Recording functions
Item Description Reference
Section
Recording interval (dot model)
Use AUX > TREND in Setting mode to set the recording interval to AUTO or FIX.
3.1
Change the recording color of measurement channels (dot model).
Use COLOR in Basic Setting mode to set the recording color of measurement channels.
Turn trend recording ON/OFF (dot model)
Use AUX > PRINT in Setting mode to turn ON/OFF the trend recording for each measurement channel.
4.5
3.6
2.4
Chart speed Use CHART in Setting mode to set the chart speed.
Record by setting recording zone for each channel
Use AUX > ZONE in Setting mode to set the recording zone for each channel.
Partial expanded recording Use PART in Basic Setting mode and select Use or Not.
If Use is selected, set the display mode using AUX > PART in Setting mode.
If Not is selected, the AUX > PART item does not appear.
3.4
4.12
3.5
Record by compensating for the pen offset along the time axis (pen model)
Use POC in Setting mode to turn ON/OFF offset compensation.
Date format Use DATE in Basic Setting mode to set the printout/display format of the date.
Periodic printout
4.6
4.14
Mar.31.2006!
15:50*
1 1.000V
2 -1.000V
0.000
1
RED
2.000
V
Channel number or tag
Measured value
Scale
Recording color
50mm/h_
(pen model)
• Printout interval
Use PER. in Basic Setting mode to set the periodic printout interval.
• Enable/Disable the periodic printout
Use PER. in Basic Setting mode to turn ON/OFF the periodic printout.
• Scale printout and recording color printout (pen model)
Use PRINT > SCALE in Basic Setting mode to turn scale printout ON/OFF.
Use PRINT > PEN color in Basic Setting mode to turn pen color printout
ON/OFF (pen model).
• Turn ON/OFF periodic printout for each channel
Use AUX > PRINT in Setting mode to turn ON/OFF the periodic printout for each measurement channel.
4.8
4.8
4.7
3.6
IM 04P03B01-01E
1-19
1
1.6 Function Setup Guide
Item Description Reference
Section
Alarm occurrence/release printout
• Turn printout ON/OFF
Use PRINT > ALARM in Basic Setting mode to select whether to print the alarm occurrence and release, print only the alarm occurrence, or not print.
• Time printout format
Use T_PRN > ALARM in Basic Setting mode to set the time printout format when printing alarm occurrence/release.
Message printout
4.7
4.16
• Set the message string
Use AUX > MSG to set the message string to be printed.
• Time printout format
Use T_PRN > MSG in Basic Setting mode to set the time printout format.
3.8
4.16
• Execute the message printout Operation Guide
Use FUNC key > MSG in Operation mode to execute the message printout. Printing a Message
New chart speed printout • Turn printout ON/OFF
Use PRINT > SPEED in Basic Setting mode to set whether to print the new chart speed when the chart speed is changed.
• Time printout format
Use T_PRN > SPEED in Basic Setting mode to set the time printout format.
Recording Start Printout • Turn printout ON/OFF
Use PRINT > RCD in Basic Setting mode to enable/disable the recording start printout.
• Time printout format
Use T_PRN > RCD in Basic Setting mode to set the time printout format.
Channel/tag selection
4.7
4.16
4.7
4.16
• Use PRINT > TAG. CH in Basic Setting mode to select whether to use channel 4.7
numbers or tags in printouts.
• Use AUX > TAG in Setting mode to set the tag name.
3.7
Display functions
Item
Date format
Description
Same as the Date format in “Recording functions.”
Reference
Section
4.14
Other functions
Item
Key lock
Customize menu
Font
Description Reference
Section
4.9
• Target keys and password
Use LOCK in Basic Setting mode to set the keys to be key-locked and the password.
• Enable the key lock
Use FUNC key > LOCK in Operation mode to turn key lock ON/OFF.
Operation Guide
Activating/Releasing the Key Lock
• FUNC key target menu selection
Use S.MENU > FUNC in Basic Setting mode to set the menus you wish to hide to OFF.
• Setting mode target menu selection
4.21
4.20
Use S.MENU > SET in Basic Setting mode to set the menus you wish to hide to OFF.
• Customize menu execution 4.22
Use CUST.M in Basic Setting mode to select whether to use the customized menu.
Use FONT in Basic Setting mode to set the characters used in the recording.
4.13
Remote control function (/R1 option)
Item Description
Remote control function • Assign functions to the remote control input terminals
Use REM in Basic Setting mode to set the function to be assigned to the remote control input terminal.
• Secondary chart speed
If “chart speed switching” is assigned, use AUX > SPD_2 in Setting mode to set the secondary chart speed.
1-20
Reference
Section
4.18
3.9
IM 04P03B01-01E
Chapter 2 Frequently Used Setup Operations (Setting Mode)
2.1
Setting the Input Range
Input range can be set for each measurement channel. Set unused channels to Skip.
If you change the input range, set the bias, measured and correction values (/CC1 option), alarm, and partial expanded recording again.
Procedure
TC, RTD, and DC Voltage
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
For the procedure on how to enter values or characters, see page 18 in the
Operation Guide
.
To change the polarity, press the or key when the leftmost digit of the value is blinking.
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Select “RANGE.”
(RANGE)
Select the channel number.
(CH1)
Select the input type.
(TC)
Channel number
Select the range.
(R)
Set the left span value.
Span left
Set the right span value.
Span right
The settings are activated.
(OK)
3.
Press the key to set other channels.
If you are done, press the key.
4.
Hold down the
MENU
key for 3 seconds to return to Operation mode.
2
2-1
IM 04P03B01-01E
2.1 Setting the Input Range
Description
• Selectable Range of Input Range, Span Left, and Span Right
The input range, span left, and span right can be set in the range shown below. Span left and span right cannot be set to the same value.
) DC voltage (
Range Type
20 mV(
60 mV(
200 mV(
2 V( )
6 V(
20 V(
)
50 V( )
)
)
)
)
Selectable Span Range
–20.00 to 20.00 mV
–60.00 to 60.00 mV
–200.0 to 200.0 mV
–2.000 to 2.000 V
–6.000 to 6.000 V
–20.00 to 20.00 V
–50.00 to 50.00 V
Thermocouple (
Range Type
R ( )
S ( )
B ( )
K ( )
E ( )
J ( )
T ( )
N ( )
W ( )
L ( )
U ( )
WRe ( )
RTD (
Range Type
PT (Pt100) (
JPT(JPt100) (
)
)
)
)
Selectable Span Range (°C)
0.0 to 1760.0°C
0.0 to 1760.0°C
0.0 to 1820.0°C
–200.0 to 1370.0°C
–200.0 to 800.0°C
–200.0 to 1100.0°C
–200.0 to 400.0°C
0.0 to 1300.0°C
0.0 to 2315.0°C
–200.0 to 900.0°C
–200.0 to 400.0°C
0.0 to 2400.0°C
Selectable Span Range (°C)
–200.0 to 600.0°C
–200.0 to 550.0°C
Selectable Span Range (°F)
32 to 3200°F
32 to 3200°F
32 to 3308°F
–328 to 2498°F
–328.0 to 1472.0°F
–328.0 to 2012.0°F
–328.0 to 752.0°F
32 to 2372°F
32 to 4199°F
–328.0 to 1652.0°F
–328.0 to 752.0°F
32 to 4352°F
Selectable Span Range (°F)
–328.0 to 1112.0°F
–328.0 to 1022.0°F
/N1 option
Selectable
Settings
Cu1
Cu2
Cu3
Cu4
Cu5
Cu6
Cu25
Input Type
Cu10 (GE)
Cu10 (L&N)
Cu10 (WEED)
Cu10 (BAILEY)
Cu10: a = 0.00392 at 20 ° C
Cu10: a = 0.00393 at 20 ° C
Cu25*: a = 0.00425 at 0 ° C
/N3 option
Selectable
Setting
Input Type Notes
PLATI PLATINEL
NiMo NiNiMo
W/WRe W/WRe26
N2
Kp
Type N (AWG14)
Kp vs Au7Fe
Pt4 Pt25 RTD
Pt3 Pt50
Ni3 Ni120
J263 J263*B
Cu8 Cu53
Cu9 Cu100: a = 0.00425 at 0
°
C
2-2
IM 04P03B01-01E
IM 04P03B01-01E
2.1 Setting the Input Range
1-5V Input
Select “RANGE.”
(RANGE)
Select the channel number.
(CH1)
Select “1-5V.”
(1-5V)
Channel number
Set the left span value.
Span left
Set the right span value.
Span right
Select the left scale value and the decimal place.
Scale left Decimal point
Select the right scale value.
Scale right
(When low-cut is enabled)
Select whether to use low-cut.
Low-cut
(ON)
The settings are activated.
(OK)
Description
• Span Left and Span Right
Selectable span left range: 0.8 to 1.2 V
Selectable span right range: 4.8 to 5.2 V
• Scale Left and Scale Right
Selectable range (mantissa): –19999 to 30000
Decimal place: XXXXX, XXXX.X, XXX.XX, XX.XXX, X.XXXX
To set the decimal place, press the or key while the of the setup item of scale left is blinking.
Make sure that scale left is less than scale right.
• Low-Cut
ON ( ): Cuts values less than or equal to 0% of the recording span (sets
OFF ( such values to 0% (scale left value)).
): Does not apply the low-cut function.
<Related Topics>
Enabling the low-cut function: Section 4.15
2
2-3
2.1 Setting the Input Range
Linear Scaling
Select “RANGE.”
(RANGE)
Select the channel number.
(CH1)
Select “SCALE.”
(SCALE)
Channel number
Select the input type.
(VOLT)
Select the range.
(2V)
Set the left span value.
Span left
Set the right span value.
Span right
Select the left scale value and the decimal place.
Scale left
Decimal point
Select the right scale value.
Scale right
The settings are activated.
(OK)
Description
• Scale Left and Scale Right
Selectable range (mantissa): –19999 to 30000
Decimal place: XXXXX, XXXX.X, XXX.XX, XX.XXX, X.XXXX
To set the decimal place, press the or key while the of the setup item of scale left is blinking.
2-4
IM 04P03B01-01E
IM 04P03B01-01E
2.1 Setting the Input Range
Delta Computation
Select “RANGE.”
(RANGE)
Select the channel number.
(CH2)
Select “DELTA.”
(DELTA)
Channel number
Select the reference channel.
(CH1)
Set the left span value.
Span left
Set the right span value.
Span right
The settings are activated.
(OK)
Description
• Reference Channel
The reference channel must be a channel that is smaller in channel number than the channel being set.
• Span Left and Span Right
The range type is the same as the reference channel. The span left and span right can be set in the range shown below. Span left and span right cannot be set to the same value.
Input Type
(
DC voltage
)
Range Type
20 mV (
60 mV (
200 mV (
2 V (
6 V (
20 V (
50 V (
)
)
)
)
(
(
Thermocouple R ( )
) S ( )
B ( )
K ( )
E ( )
J ( )
T ( )
N ( )
W ( )
L ( )
U ( )
WRe (
RTD
)
PT(Pt100) (
JPT(JPt100) (
)
)
)
)
Selectable Span Range (°C) Selectable Span Range (°F)
–20.00 to 20.00 mV
–60.00 to 60.00 mV
) –200.0 to 200.0 mV
–2.000 to 2.000 V
–6.000 to 6.000 V
–20.00 to 20.00 V
–50.00 to 50.00 V
–1760.0 to 1760.0°C
–1760.0 to 1760.0°C
–1820.0 to 1820.0°C
–1570.0 to 1570.0°C
–1000.0 to 1000.0°C
–1300.0 to 1300.0°C
–600.0 to 600.0°C
–1300.0 to 1300.0°C
–1999.9 to 2315.0°C
–1100.0 to 1100.0°C
–600.0 to 600.0°C
–1999.9 to 2400.0°C
–800.0 to 800.0°C
) –750.0 to 750.0°C
–3168 to 3168°F
–3168 to 3168°F
–3276 to 3276°F
–2826 to 2826°F
–1800 to 1800°F
–1999.9 to 2340.0°F
–1080.0 to 1080.0°F
–2340 to 2340°F
–4167 to 4167°F
–1980 to 1980°F
–1080.0 to 1080.0°F
–4320 to 4320°F
–1440.0 to 1440.0°F
–1350.0 to 1350.0°F
2
2-5
2.1 Setting the Input Range
ON/OFF Input
Select “RANGE.”
(RANGE)
Select the channel number.
(CH1)
Select “DI.”
(DI)
Channel number
Select contact or level.
(CONT)
Set the left span value.
Span left
Set the right span value.
Span right
The settings are activated.
(OK)
Description
• Selectable Range of Input Range, Span Left, and Span Right
The input range, span left, and span right can be set in the range shown below. Span left and span right cannot be set to the same value.
Range Type
Level (
Contact ( )
)
Selectable Span Values
0: Less than 2.4 V, 1: 2.4 V or higher, within ±6 V
0: Open, 1: Closed
2-6
IM 04P03B01-01E
2.1 Setting the Input Range
IM 04P03B01-01E
Square Root Computation
Select “RANGE.”
(RANGE)
Select the channel number.
(CH1)
Select “SQRT.”
(SQRT)
Channel number
(2V)
Select from the range types of DC voltage.
20 mV, 60 mV, 200 mV, 2 V, 6 V, 20 V, or 50 V
Set the left span value.
Span left
Set the right span value.
Span right
Select the left scale value and the decimal place.
Scale left
Decimal point
Scale right
(ON)
Low-cut
Select the right scale value.
(Displays the following when the low-cut is enabled)
Turn ON or OFF the low-cut function.
Set the low-cut point.
0.0 to 5.0% of the recording span, 0.1 steps.
The settings are activated.
(OK)
Description
• Input Type on Which Square Root Computation Can Be Performed
Square root computation can be performed when set to DC voltage input.
• Span Left and Span Right
Same as the selectable span range of the DC voltage range.
Make sure that span left is less than span right.
• Scale Left and Scale Right
Selectable range (mantissa): –19999 to 30000
Decimal place: XXXXX, XXXX.X, XXX.XX, XX.XXX, X.XXXX
To set the decimal place, press the or key while the of the setup item of scale left is blinking.
Make sure that scale left is less than scale right.
• Low-Cut and Low-Cut Point
If low-cut is set to ON, set the low-cut point.
Selectable range of the low-cut point: 0.0 to 5.0% of the recording span
Values below the low-cut point is set to 0% of the recording span (scale left value).
<Related Topics>
Enabling the low-cut function: Section 4.15
2-7
2
2.1 Setting the Input Range
Skip (Unused Channels)
Select “RANGE.”
(RANGE)
Select the channel number.
(CH1)
Select “SKIP.”
(SKIP)
Channel number
The settings are activated.
(OK)
Note
Do not use channels set to skip as a reference channel of delta computations.
2-8
IM 04P03B01-01E
2.2
Setting the Alarm
An alarm can be set for each channel.
If you change the input range, set the alarm again.
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
For the procedure on how to enter values or characters, see page 18 in the
Operation Guide
.
To change the polarity, press the or key when the leftmost digit of the value is blinking.
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Select the “ALARM.”
(ALARM)
Select the channel number.
(CH1)
Select the level number between 1 and 4.
(L4)
Channel number
Select ON to set the alarm.
(ON)
Level number
(Displays the following when the alarm is ON)
Select the alarm type.
(H)
Set the value used to turn ON the alarm.
(ON)
Relay output
Select ON to set the alarm relay output.
This setting is valid only on models with the /A1, /A2, or /A3 option.
(When the alarm output is ON)
Specify the alarm output relay number.
(I01)
The settings are activated.
(OK)
3.
Press the key to set other channels.
If you are done, press the key.
4.
Hold down the
MENU
key for 3 seconds to return to Operation mode.
2
2-9
IM 04P03B01-01E
2.2 Setting the Alarm
Explanation
Alarm Type
Symbol Name
H ( ) High limit alarm
L ( ) h ( ) l ( )
Low limit alarm
Difference high limit alarm
Difference low limit alarm
Notes
Can be specified on channels set to delta computation.
Can be specified on channels set to delta computation.
Note
On channels set to delta computation, alarms can be detected on the values illustrated in the figure below.
Alarm on a channel set to delta computation
Alarm
H, L
Alarm h, l
Input value
Measured value
−
Measured value on the reference channel
Alarm Value
• High Limit Alarm/Low Limit Alarm
The following values can be specified.
• For DC voltage, thermocouple, or RTD:
Values within the measurable range in the input range (example: –2.000 to
2.000 V for the 2 V input range).
• For ON/OFF input (DI): 0 or 1.
• For linear scaling (1-5V, scaling, and square root):
A value within –5 to 105% of the scaling span and within the range of
–19999 to 30000 (excluding the decimal point).
• Difference High Limit Alarm/Difference Low Limit Alarm
Values in the measurable range can be specified.Measurable range refers to
“Selectable Span Range” in the table on page 2-5.
Relay No.
The selectable relay numbers are listed below.
I01 and I02 on the /A1 option
I01, I02, I03, and I04 on the /A2 option
I01, I02, I03, I04, I05, and I06 on the /A3 option
<Related Topics>
Setting the auxiliary alarm function: Section 4.1
2-10
IM 04P03B01-01E
2.3
Setting the Unit on Linearly Scaled Channels
Units can be assigned on channels whose input range is set to Scale, 1-5V, or
SQRT.The assigned unit is added when printing to the chart paper or during data transmission.
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
For the procedure on how to enter values or characters, see page 18 in the
Operation Guide .
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Select “UNIT.”
(UNIT)
Select the channel number.
(CH1)
Enter the ASCII code of the 1 st
character.
1 st
char. 1 st character ASCII code
Enter the ASCII code of the 2 nd
character.
2 nd
char.
2 nd
character ASCII code
Enter the ASCII code of the 3 rd
character.
3 rd
character ASCII code
:
:
Enter the ASCII code of the 6 th
character.
6 th character ASCII code
The settings are activated.
(OK)
3.
Press the key to set other channels.
If you are done, press the key.
4.
Hold down the
MENU
key for 3 seconds to return to Operation mode.
Explanation
Characters That Can Be Used for Units
A unit is set using up to six characters.
The available characters are as follows:
Alphabet, numbers, symbols (%, #, °, @, +, –, ∗, /, (, ), µ, Ω,
2
,
3
, .), and space
2
2-11
IM 04P03B01-01E
2-12
2.4
Changing the Chart Speed
The chart speed can be changed.
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
If you press the key, the operation is cancelled, and the display returns to a higher level menu.
Select the “CHART.”
(CHART)
Select the chart speed.
Explanation
The settings are activated.
(OK)
3.
If you are done, press the key.
4.
Hold down the
MENU
key for 3 seconds to return to Operation mode.
Chart Speed
• Pen model: Select from the 40 settings shown below.
• Dot model: Select from the 28 settings in the thick frame shown below.
Chart speed (the chart speed of the dot model is inside the thick frame) (Unit: mm/h)
10 15 20 25 30 40 50 60 75 80
90 100 120 150 160 180 200 240 300 360
3000 3600 4500 4800 5400 6000 7200 9000 12000
<Related Topics>
Disabling the new chart speed printout: Section 4.7
IM 04P03B01-01E
2.5
Setting the Date/Time
The date/time can be set.
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
For the procedure on how to enter values or characters, see page 18 in the
Operation Guide .
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Select “CLOCK.”
(CLOCK)
Set the year, month, and day.
Year
Month Day
Sets the hour, minute, and second.
Hour
Minute Second
The settings are activated.
(OK)
3.
If you are done, press the key.
4.
Hold down the
MENU
key for 3 seconds to return to Operation mode.
Explanation
Date/Time
Set the lower two digits of the year.
Values in the range 80 and 99 correspond to 1980 to 1999.
Note
When setting the date/time, the year, month, day, hour, minute, and second are displayed in the order shown above regardless of the printout/display format of the date (see section 4.14).
<Related Topics>
Changing the printout/display format of the date: Section 4.14
Changing the printout format of the time: Section 4.16
2
2-13
IM 04P03B01-01E
Chapter 3 Setup Operations for Convenient Functions (Setting Mode)
3.1
Setting the Trend Recording Interval (Dot
Model)
The trend recording interval (dot printing interval) on the dot model can be set.
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
If you press the key, the operation is cancelled, and the display returns to a higher level menu.
Select the “AUX.”
(AUX)
Select “TREND.”
(TREND)
Set the dot printing interval to AUTO or FIX.
(AUTO)
The settings are activated.
(OK)
3.
If you are done, press the key.
4.
Hold down the
MENU
key for 3 seconds to return to Operation mode.
Explanation
Trend Recording Interval
AUTO ( ): The trend recording interval is set according to the chart speed so
FIX ( ): that the dots do not overlap.
The trend recording interval is fixed to 10 s/6 dots.
When set to AUTO
Dot
When set to FIX
3
Recording Intervals When AUTO Is Selected
Chart speed
10 mm/h
15 mm/h
20 mm/h
25 mm/h
30 mm/h
40 mm/h
50 mm/h
60 mm/h
75 mm/h
80 mm/h
90 mm/h or faster
Integration Time Set to 50Hz/60Hz/AUTO
90 s
60 s
45 s
36 s
30 s
22 s
18 s
15 s
12 s
11 s
10 s
Integration Time Set to 100 ms
90 s
60 s
45 s
35 s
30 s
22.5 s
17.5 s
15 s
10 s
10 s
10 s
3-1
IM 04P03B01-01E
3-2
3.2
Setting the Filter (Pen Model)
A filter can be set on the measurement channels on the pen model.
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
If you press the key, the operation is cancelled, and the display returns to a higher level menu.
Select the “AUX.”
(AUX)
Select “FILTR.”
(FILTR)
Select the channel number.
(CH1)
Select the filter time constant.
(OFF)
Channel number
The settings are activated.
(OK)
3.
Press the key to set other channels.
If you are done, press the key.
4.
Hold down the
MENU
key for 3 seconds to return to Operation mode.
Explanation
Filter Time Constant
The time constant is selectable from 2 s, 5 s, and 10 s. Select OFF when not using the filter.
<Related Topics>
Enabling the filter function: Section 4.11
IM 04P03B01-01E
3.3
Setting the Moving Average (Dot Model)
The moving average function can be set on the measurement channels on the dot model.
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Select the “AUX.”
(AUX)
Select “M_AVE.”
(M_AVE)
Select the channel number.
(CH1)
Select the number of samples of the moving average.
(OFF)
Channel number
The settings are activated.
(OK)
3.
Press the key to set other channels.
If you are done, press the key.
4.
Hold down the
MENU
key for 3 seconds to return to Operation mode.
Explanation
Number of Samples of Moving Average
The number of samples can be set to an integer between 2 and 16. Select OFF when not using the moving average function.
<Related Topics>
Enabling the moving average: Section 4.10
3
3-3
IM 04P03B01-01E
3-4
3.4
Setting Recording Zones for Each Channel
(Zone Recording)
A recording zone can be set for each measurement channel.
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
For the procedure on how to enter values or characters, see page 18 in the
Operation Guide .
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Select the “AUX.”
(AUX)
Select “ZONE.”
(ZONE)
Select the channel number.
(CH1)
Channel number
Set the leftmost position of the recording zone.
Leftmost position
Set the rightmost position of the recording zone.
Rightmost position
The settings are activated.
(OK)
3.
Press the key to set other channels.
If you are done, press the key.
4.
Hold down the
MENU
key for 3 seconds to return to Operation mode.
Explanation
Recording Zone
The recording zone can be set in the following range.
Leftmost position: 0 mm to 95 mm
Rightmost position: 5 mm to 100 mm
Set a larger value for the rightmost position than the leftmost position.
Set at least 5 mm for the recording zone width.
Note
If the recording zone is set to a value less than 40 mm, scale printout of periodic printout cannot be executed.
IM 04P03B01-01E
3.5
Setting the Partial Expanded Recording
A section of the recording range can be expanded.
If you change the input range, set the partial expanded recording again.
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
For the procedure on how to enter values or characters, see page 18 in the
Operation Guide
.
To change the polarity, press the or key when the leftmost digit of the value is blinking.
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Select the “AUX.”
(AUX)
Select the “PART.”
(PART)
Select the channel number.
(CH1)
Select ON to set the partial expanded recording function.
(ON)
Channel number
(When partial expanded recording is ON)
Set the boundary position. (A value when the record span is assumed to be 100%)
Boundary position
Set the boundary value within the recording span.
Boundary value
The settings are activated.
(OK)
3.
Press the key to set other channels.
If you are done, press the key.
4.
Hold down the
MENU
key for 3 seconds to return to Operation mode.
Explanation
Boundary Position
Set a value between 1 and 99%.
<Related Topics>
Enabling the partial expanded recording function: Section 4.12
3
3-5
IM 04P03B01-01E
3-6
3.6
Turning Trend Recording (Dot Model) and
Periodic Printout ON/OFF for Each Channel
This section explains the details of setting the trend recording and periodic printout for each measurement channel.
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Select the “AUX.”
(AUX)
Select “PRINT.”
(PRINT)
Select the channel number.
(CH1)
(Dot model only)
Turn trend recording ON/OFF.
(ON)
Trend recording
Select whether to print the measured values in periodic printout.
(ON)
Periodic printout
The settings are activated.
(OK)
3.
Press the key to set other channels.
If you are done, press the key.
4.
Hold down the
MENU
key for 3 seconds to return to Operation mode.
Explanation
The following settings can be entered for each channel on the dot model.
• Turn trend recording ON/OFF.
• Turn the printing of measured values ON/OFF during periodic printout.
The following settings can be entered for each channel on the pen model.
• Turn the printing of measured values ON/OFF during periodic printout.
<Related Topics>
Setting the periodic printout: Section 4.8
IM 04P03B01-01E
3.7
Setting Tags on Channels
Tags can be assigned to measurement channels.
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
For the procedure on how to enter values or characters, see page 18 in the
Operation Guide .
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Select the “AUX.”
(AUX)
Select “TAG.”
(TAG)
Select the channel number.
(CH1)
Enter the ASCII code of the 1 st
character.
1 st
char.
1 st
character ASCII code
Enter the ASCII code of the 2 nd
character.
2 nd
char.
2 nd
character ASCII code
Enter the ASCII code of the 3 rd
character.
3 rd
character ASCII code
:
:
Enter the ASCII code of the 7 th
character.
7 th
character ASCII code
The settings are activated.
(OK)
3.
Press the key to set other channels.
If you are done, press the key.
4.
Hold down the
MENU
key for 3 seconds to return to Operation mode.
Explanation
Characters That Can Be Used for Tags
Set a tag using up to seven characters.
The available characters are as follows:
Alphabet, numbers, symbols (%, #, °, @, +, –, ∗, /, (, ), µ, Ω,
2
,
3
, .), and space
<Related Topics>
Printing tags in place of channel numbers: Section 4.7
3-7
IM 04P03B01-01E
3
3-8
3.8
Setting the Message String
Message strings to be printed on the chart paper can be set. Up to five message strings can be registered.
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
For the procedure on how to enter values or characters, see page 18 in the
Operation Guide
.
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Select the “AUX.”
(AUX)
Select “MSG.”
(MSG)
Select the message number.
(MSG1)
Enter the ASCII code of the 1 st
character.
1 st
char.
1 st
character ASCII code
Enter the ASCII code of the 2 nd
character.
2 nd
char.
2 nd
character ASCII code
Enter the ASCII code of the 3 rd
character.
3 rd
character ASCII code
:
:
Enter the ASCII code of the 16 th
character.
16 th
character ASCII code
The settings are activated.
(OK)
3.
Press the key to set other message numbers.
If you are done, press the key.
4.
Hold down the
MENU
key for 3 seconds to return to Operation mode.
Explanation
Characters That Can Be Used for Messages
Set a message using up to 16 characters.
The available characters are as follows:
Alphabet, numbers, symbols (%, #, °, @, +, –, ∗, /, (, ), µ, Ω,
2
,
3
, .), and space
<Related Topics>
Printing a message: “Printing a Message” in the Operation Guide
IM 04P03B01-01E
3.9
Setting the Secondary Chart Speed (Remote
Control Function, /R1)
The secondary chart speed when the chart speed is to be switched using the remote control function (/R1 option) can be set.
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Select the “AUX.”
(AUX)
Select “SPD_2.”
(SPD_2)
Select the secondary chart speed.
3
Explanation
The settings are activated.
(OK)
3.
If you are done, press the key.
4.
Hold down the
MENU
key for 3 seconds to return to Operation mode.
Chart Speed
See section 2.4.
<Related Topics>
Setting the remote control function: Section 4.18
3-9
IM 04P03B01-01E
3-10
3.10 Applying a Bias on the Measuring Input Signal
A bias can be applied to the scaled value of the measuring input signal.
If you change the input range, set the bias again.
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
For the procedure on how to enter values or characters, see page 18 in the
Operation Guide
.
To change the polarity, press the or key when the leftmost digit of the value is blinking.
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Select “BIAS.”
(BIAS)
Select the channel number.
(CH1)
Select ON to set the bias.
(ON)
Channel number
(When bias is ON)
Enter the bias value.
The settings are activated.
(OK)
3.
Press the key to set other channels.
If you are done, press the key.
4.
Hold down the
MENU
key for 3 seconds to return to Operation mode.
Explanation
Bias
The range of bias that can be specified is approximately ±10% of the measurable range of the input range. For example, the range is –0.4 V to 0.4 V for the 2 V input range.
For channels on which scaling is set, the range is approximately ±10% of the scaling width.
Note
A bias cannot be set on channels set to ON/OFF input (DI). In addition, the bias function cannot be used on all channels if calibration correction (/CC1 option) is used.
<Related Topics>
Enabling the bias function: Section 4.15
IM 04P03B01-01E
3.11 Performing Calibration Correction (/CC1 Option)
The scaled values of the measuring input signal are corrected using specified segments, and the results are used as measured values.
If you change the input range, set the measured and correction values again.
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
For the procedure on how to enter values or characters, see page 18 in the
Operation Guide
.
To change the polarity, press the or key when the leftmost digit of the value is blinking.
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Select “CALIB.”
(CALIB)
Select the channel number.
(CH1)
(ON)
Channel number
Select ON to set the calibration correction.
(Displays the following when the calibration correction is ON)
Enter the measured value of the 1 st
point.
Measured value of the
1 st
point
Enter the calibration value of the 1 st
point.
Correction value of the
1 st
point
Enter the measured value of the 2 th
point.
Measured value of the
2 nd
point
Enter the calibration value of the 2 th
point.
Correction value of the
2 nd
point
:
:
Enter the measured value of the 16 th
point.
Measured value of the
16 th
point
Enter the calibration value of the 16 th
point.
Correction value of the
16 th
point
Save the settings.
(STORE)
The settings are activated.
Setting example when the calibration correction method is set to revise value and the number of calibration correction points is set to 16
3-11
IM 04P03B01-01E
(ON)
3
3.11 Performing Calibration Correction (/CC1 Option)
3.
Press the key to set other channels.
If you are done, press the key.
4.
Hold down the
MENU
key for 3 seconds to return to Operation mode.
Explanation
Setting Measured and Corrected Values
• Using revise values
Scale value
Measured value
A3
B4
B2
A4
B3
Correction value
A1
A2
Calibration point
B1
Correction using revise values
Measured value = A
Correction value = B – A
• Using absolute values
Scale value
A1
B1
Measured value
A3
B4
B2
A4
B3
Correction value
A2
Correction using absolute values
Measured value = A
Correction value = B
Calibration point
Example of a two-point correction
Calibration
Correction
Point
1
2
Corrected
Value
10.0
90.0
°
°
C
C
Measured value (A)
9.8
°
90.5
C
°
C
Correction Value
Revise Value
(B – A)
0.2
°
C
– 0.5
°
C
Absolute
Value (B)
10.0
90.0
°
°
C
C
Setup Conditions of Measured and Corrected Values
• Setting range of measured and correction values when using revise values
A1 < A2 ≤ A3 ≤ ... ≤ A16
(A1 + B1) < (A2 + B2) < (A3 + B3) < ... < (A16 + B16)
A and B are within the measurable range or scaling range of the range type*
* Within the scaling range: –5% to 105% of the scale value or –19999 to 30000 (the decimal place is the same as the setting for the scale value)
• Setting range of measured and correction values when using absolute values
A1 < A2 ≤ A3 ≤ ... ≤ A16
B1 < B2 < B3 < ... < B16
A and B are within the measurable range or scaling range of the range type*
* Within the scaling range: –5% to 105% of the scale value or –19999 to 30000 (the decimal place is the same as the setting for the scale value)
Note
• Make sure that the leftmost value is less than the rightmost value for span and scale.
• Calibration correction cannot be set on ON/OFF input (DI), delta computation, and square root computation channels. In addition, calibration correction cannot be used on all channels if the bias function is enabled.
<Related Topics>
Enabling the calibration correction function: Section 4.15
Setting the calibration correction function: Section 4.19
3-12
IM 04P03B01-01E
3.12 Setting the Date/Time for Switching between
Standard Time and DST
The date/time for switching from the standard time to DST and the date/time for switching back from DST to standard time can be set, if the recorder is used in a region that has DST. When the preset date/time arrives, the recorder internal clock automatically switches.
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Select the “AUX.”
(AUX)
Select “DST.”
(DST)
Select whether to use the DST function.
(USE)
(Displays the following when the
DST function is set to USE)
Select the start month.
Start month
Select the start week.
(LAST)
Start week
Select the start day.
Start day
(SUN)
Select the start hour.
Start hour
Select the end month.
End month
Select the end week.
(LAST)
End week
Select the end day.
End day
(SUN)
Select the end hour.
End hour
The settings are activated.
(OK)
3-13
IM 04P03B01-01E
3
3.12 Setting the Date/Time for Switching between Standard Time and DST
3.
If you are done, press the key.
4.
Hold down the
MENU
key for 3 seconds to return to Operation mode.
Explanation
Start Month, Start Day, and Start Time
Set the date/time for switching from standard time to DST. Specify the day as the n th
day of the week of the month.
End Month, End Day, and End Time
Set the date/time for switching from DST to standard time. Specify the day as the n th
day of the week of the month.
Start Month and End Month
01 to 12: January to December
Start Week and End Week
1: 1 st
week
2: 2 nd
week
3: 3 rd
week
4: 4 th
week
: Last week
Start Day and End Day
: Sunday
: Monday
: Tuesday
: Wednesday
: Thursday
: Friday
: Saturday
Start Time and End Time
00 to 23: Hour 00 to hour 23
3-14
IM 04P03B01-01E
Chapter 4 Setup Operations for Changing/Adding Functions (Basic Setting Mode)
4.1
Changing the Auxiliary Alarm Function
This section explains the details of setting the alarm system items listed below.
• Diagnosis output using the alarm output relay (I01)
• Energized/De-energized operation of alarm output relays when alarms occur
• Alarm hysteresis
Basic Setting mode cannot be entered when recording is in progress
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Hold down the and keys simultaneously for 3 seconds to display the
Basic Setting mode screen.
3.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Select the “ALARM.”
(RANGE)
(DIAG)
Diagnosis output
Select ON to set relay I01 to diagnosis output. This setting is valid only on models with the /A1, /A2, or /A3 option.
(ON)
(RELAY)
Output relay energize/de-energize
Select the relay’s energized or de-energized operation. This setting is valid only on models with the /A1, /A2, or /A3 option.
(ENERG)
(HYS)
Hysteresis
Select the hysteresis (0.0% (OFF) to
1.0%).
(OFF)
The settings are activated.
(OK)
4.
If you are done, press the key.
5.
To return to the Operation mode,
1. Press the
key.
key, use the or key to select
2. Press the or key to select
key.
or
, and press the
, and press the
4
4-1
IM 04P03B01-01E
4.1 Changing the Auxiliary Alarm Function
Explanation
Diagnosis Output
When set to ON, alarm output relay I01 becomes a dedicated diagnosis output relay, and the operation is fixed to de-energized. Diagnosis output is a function which outputs a relay signal when an error is detected in the recording section, burnout detection function, or the A/D converter.
Output Relay Energize/De-Energize Operation
Sets whether the output relay is energized or de-energized when an alarm occurs.
Energize ( ): Energizes the relay when an alarm occurs. The relay is deenergized during normal operation.
De-energize ( ): De-energizes the relay when an alarm occurs. The relay is energized during normal operation.
Hysteresis
Sets the alarm hysteresis of the measurement channels.
The hysteresis width can be set in the range of 0.0% (OFF) to 1.0% of the recording span in 0.1 steps.
The hysteresis applies to all high limit and low limit alarms of measurement channels.
<Related Topics>
Setting the alarm: Section 2.2
4-2
IM 04P03B01-01E
4.2
Changing the Integration Time of the A/D
Converter
The integration time of the A/D converter can be set. Basic Setting mode cannot be entered when recording is in progress
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Hold down the and keys simultaneously for 3 seconds to display the
Basic Setting mode screen.
3.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Select “INTG.”
(INTG)
Select the integration time of the
A/D converter.
(AUTO)
The settings are activated.
(OK)
4.
If you are done, press the key.
5.
To return to the Operation mode,
1. Press the
key.
key, use the or
2. Press the or key to select
key to select
or
key.
, and press the
, and press the
Explanation
Integration Time
Selects the integration time of the A/D converter.
Selectable Settings Integration Time Scan Interval
(Pen Model)
50 Hz (
60 Hz (
Auto (
100 ms (
)
)
) 20 ms
16.7 ms
20 ms or 16.6 ms
*2
100 ms
125 ms
125 ms
125 ms
– )
*1
*1 Selectable only on the dot model.
*2 Automatically switch by detecting the power supply frequency.
Recording Interval
(Dot Model)
1 s
1 s
1 s
2.5 s
4
4-3
IM 04P03B01-01E
4-4
4.3
Setting the Burnout Detection Function
The burnout detection function of thermocouples can be set on 1-5V or TC input channels. Basic Setting mode cannot be entered when recording is in progress
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Hold down the and keys simultaneously for 3 seconds to display the
Basic Setting mode screen.
3.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Select “B_OUT.”
(B_OUT)
Select the channel number.
(CH1)
Select the recording operation that is carried out when a burnout is detected.
(OFF)
Channel number
The settings are activated.
(OK)
4.
Press the key to set other channels.
If you are done, press the key.
5.
To return to the Operation mode,
1. Press the
key.
key, use the or
2. Press the or key to select
key to select
or
key.
, and press the
, and press the
Explanation
Burnout
Selects the action taken when a burnout is detected at the 1-5V input or the thermocouple input.
Upscale (
Downscale (
): Records off the scale on the 100% side.
): Records off the scale on the 0% side.
OFF ( ): Disables the burnout detection function.
IM 04P03B01-01E
4.4
Setting the RJC Function on TC Input
Channels
The RJC mode can be set on TC input channels. Basic Setting mode cannot be entered when recording is in progress
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Hold down the and keys simultaneously for 3 seconds to display the
Basic Setting mode screen.
3.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
For the procedure on how to enter values or characters, see page 18 in the
Operation Guide
.
To change the polarity, press the or key when the leftmost digit of the value is blinking.
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Selects “RJC.”
(RJC)
Select the channel number.
(CH1)
(INT)
Channel number
Select the RJC mode of the thermocouple input.
(When external (EXT) is selected)
Set the compensation voltage when using the external RJC function.
The settings are activated.
(OK)
4.
Press the
1. Press the
key.
key to set other channels.
If you are done, press the key.
5.
To return to the Operation mode,
key, use the or key to select
2. Press the or key to select
key.
or
, and press the
, and press the
Explanation
RJC
Sets the RJC mode.
Internal (
External (
): Uses the RJC function of the recorder.
): Uses an external RJC function. If external is selected, set the compensation voltage.
Compensation Voltage
Sets the compensation voltage when using an external RJC function.
The compensation voltage can be set in the range of –19999 µV to 20000 µV.
4-5
IM 04P03B01-01E
4
4-6
4.5
Changing the Channel Recording Color (Dot
Model)
The trend recording color on the dot model can be changed. Basic Setting mode cannot be entered when recording is in progress
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Hold down the and keys simultaneously for 3 seconds to display the
Basic Setting mode screen.
3.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Select “COLOR.”
(COLOR)
Select the channel number.
(CH1)
Select the recording color.
(PRPLE)
Channel number
The settings are activated.
(OK)
4.
Press the key to set other channels.
If you are done, press the key.
5.
To return to the Operation mode,
1. Press the key, use the or key to select
key.
2. Press the or key to select
key.
or
, and press the
, and press the
Explanation
Color
Sets the recording color of measurement channels.
By default, the recording colors are set as follows:
Channel 1: Purple ( )
Channel 2: Red (
Channel 3: Green (
)
)
) Channel 4: Blue (
Channel 5: Brown (
Channel 6: Black ( )
)
IM 04P03B01-01E
4.6
Recording by Compensating for the Pen Offset along the Time Axis (Pen Model)
The pen offset along the time axis (pen model) can be compensated. Basic Setting mode cannot be entered when recording is in progress
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Hold down the and keys simultaneously for 3 seconds to display the
Basic Setting mode screen.
3.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Select “POC.”
(POC)
Select ON to record by compensating for the pen offset along the time axis.
(OFF)
The settings are activated.
(OK)
4.
If you are done, press the key.
5.
To return to the Operation mode,
1. Press the
key.
key, use the or
2. Press the or key to select
key to select
or
key.
, and press the
, and press the
Explanation
When pen offset compensation is turned ON, an asterisk is printed by the time on the periodic printout.
Note
When pen offset compensation is enabled, all pens are aligned with the reference pen (pen that is furthest to the back: pen 2 on the 2-pen model, pen 3 on the 3-pen model, and pen 4 on the 4pen model) for recording. When recording is started, only the reference pen moves until the offset is compensated. This is not a malfunction.
4
4-7
IM 04P03B01-01E
4-8
4.7
Turning Printouts ON/OFF
Select whether to print using channel numbers or tags and set whether to print the various printout items. Basic Setting mode cannot be entered when recording is in progress.
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Hold down the and keys simultaneously for 3 seconds to display the
Basic Setting mode screen.
3.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
If you press the key, the operation is cancelled, and the display returns to a higher level menu.
Select “PRINT.”
(PRINT)
(CH.TAG)
Channel No./tag printout
Select whether to use the channel numbers (CH) or tags (TAG) for the printout.
(CH)
(CHPRN)
Channel No. printout (Dot model only)
Select whether to print the channel number or tag by the trend recording.
Select ON or OFF.
(ON)
(ALARM)
Alarm printout
Select whether to print the alarm occurrence/release (ON1, ON2 or OFF).
(ON1)
(RCD)
Recording start printout
Select whether to perform recording start printout. Select ON or OFF.
(OFF)
(SPEED)
New chart speed printout
Select whether to perform new chart speed printout. Select ON or OFF.
(ON)
To the next page
IM 04P03B01-01E
Explanation
4.7 Turning Printouts ON/OFF
From the previous page
(SCALE)
Scale printout
Select whether to print the channel scale in periodic printout. Select ON or OFF.
(ON)
(PEN)
Recording color printout
(pen model only)
Select whether to print the recording color in periodic printout. Select ON or OFF.
This is valid on channels whose scale printout is turned ON.
(ON)
The settings are activated.
(OK)
4.
If you are done, press the key.
5.
To return to the Operation mode,
1. Press the key, use the or key to select
key.
2. Press the or key to select
key.
or
, and press the
, and press the
Channel Number/Tag Printout
Channel ( ): Prints the channel number.
Tag ( ): Prints the tag.
Alarm Printout
ON1 (
ON2 (
OFF (
): Prints the alarm information when an alarm occurs or releases.
): Prints the alarm information only when an alarm occurs.
): Does not print alarm information.
4
IM 04P03B01-01E
4-9
4-10
4.8
Setting the Periodic Printout
Procedure
Explanation
The periodic printout settings can be specified. Basic Setting mode cannot be entered when recording is in progress
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Hold down the and keys simultaneously for 3 seconds to display the
Basic Setting mode screen.
3.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
For the procedure on how to enter values or characters, see page 18 in the
Operation Guide
.
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Select “PER.”
(PER.)
Select the periodic printout interval mode.
(AUTO)
Set the reference time for the printout.
(00:00)
(When the interval mode is manual)
Select the periodic printout interval.
(1H)
Select whether to enable (INST) or disable (OFF) the periodic printout.
(INST)
The settings are activated.
(OK)
4.
If you are done, press the key.
5.
To return to the Operation mode,
1 . Press the key, use the or key to select
key.
2. Press the or key to select
key.
or
, and press the
, and press the
Periodic Printout
Selects the periodic printout interval mode.
Auto ( ): Automatically sets the printout interval in sync with the chart speed.
Manual ( ): Set the printout interval manually.
Reference Time
Sets the reference time for determining the times for executing the periodic printout.
The reference time is set in the range of 00 to 23 in 1 hour steps. Minutes cannot be specified.
(
Interval
Select the interval from 10, 12, 15, 20, 30 minutes, 1, 2, 3, 4, 6, 8, 12, and 24 hours
to ).
Turning ON/OFF the Periodic Printout
ON (instantaneous value) ( ): Prints the measured value at that point.
OFF ( ): Disables periodic printout.
IM 04P03B01-01E
4.9
Setting the Key Lock
The keys that can be locked and the password for releasing the key lock can be set.
Basic Setting mode cannot be entered when recording is in progress
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Hold down the and keys simultaneously for 3 seconds to display the
Basic Setting mode screen.
3.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
For the procedure on how to enter values or characters, see page 18 in the
Operation Guide
.
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Select “LOCK.”
(LOCK)
(USE)
Select "USE" to set the target keys of the key lock.
(Displays the following when the target key setting is set to USE)
Set the password.
(****)
(RCd)
RCD key
Select whether to lock the key
(LOCK or FREE).
(FREE)
(FEED)
FEED key
Select whether to lock the key
(LOCK or FREE).
(FREE)
(MENU)
MENU key
Select whether to lock the key
(LOCK or FREE).
(FREE)
(M_PRN)
Manual printout
Select whether to lock the key
(LOCK or FREE).
(FREE)
To the next page
4-11
IM 04P03B01-01E
4
4.9 Setting the Key Lock
From the previous page
(LIST)
List printout
Select whether to lock the key
(LOCK or FREE).
(FREE)
(SLIST)
Setup list printout
Select whether to lock the key
(LOCK or FREE).
(FREE)
(MSG)
Message printout
Select whether to lock the key
(LOCK or FREE).
(FREE)
(B-CLR)
Printout buffer clear
Select whether to lock the key
(LOCK or FREE).
(FREE)
(PEN)
Pen exchange (Pen model only)
Select whether to lock the key
(LOCK or FREE).
(FREE)
(RIBON)
Ribbon exchange (Dot model only)
Select whether to lock the key
(LOCK or FREE).
(FREE)
The settings are activated.
(OK)
4.
If you are done, press the key.
5.
To return to the Operation mode,
1. Press the key, use the or key to select
key.
2. Press the or key to select
key.
or
, and press the
, and press the
4-12
IM 04P03B01-01E
Explanation
4.9 Setting the Key Lock
Key Lock
Select the target keys (
Not use the key lock ( )
)
Password
Sets the password for releasing the key lock. Set the password using a four-digit number.
Operation of Keys to Be Key-Locked
Sets the operation of the keys to be key-locked. Select Lock (
(
RCD:
) for each key operation.
RCD
key
) or Free
FEED:
FEED
key
MENU:
MENU
key
M_PRN:
FUNC
key + manual printout operation
LIST:
FUNC
key + list printout operation
SLIST:
FUNC
key + setup list printout operation
MSG:
FUNC
key + message printout operation
B_CLR:
FUNC
key + clear operation of the printout buffer memory
PEN:
FUNC
key + the operation of moving the pen to an easily accessible position of replacement (pen model)
RIBON:
FUNC
key + the operation carried out when replacing the ribbon cassette with the power turned ON (dot model)
<Related Topics>
Activating/Releasing the Key Lock: “Activating/Releasing the Key Lock” in the
Operation
Guide
4
IM 04P03B01-01E
4-13
4-14
4.10 Enabling the Moving Average Function (Dot
Model)
The moving average function can be enabled/disabled on the dot model. Basic Setting mode cannot be entered when recording is in progress
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Hold down the and keys simultaneously for 3 seconds to display the
Basic Setting mode screen.
3.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Select “M_AVE.”
(M_AVE)
Select whether to use moving average function.
(NOT)
The settings are activated.
(OK)
4.
If you are done, press the key.
5.
To return to the Operation mode,
1. Press the key, use the or key to select
key.
2. Press the or key to select
key.
or
, and press the
, and press the
Explanation
Moving Average
Enable ( ): Enables the setting of the number of samples of the moving average
Disable ( in Setting mode.
): The “M_AVE” item does not appear in Setting mode.
<Related Topics>
Setting the moving average: section 3.3
IM 04P03B01-01E
4.11 Enabling the Filter Function (Pen Model)
The input filter function on the pen model can be enabled/disabled. Basic Setting mode cannot be entered when recording is in progress
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Hold down the and keys simultaneously for 3 seconds to display the
Basic Setting mode screen.
3.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Select “FILTR.”
(FILTR)
Select whether to use the filter function.
(NOT)
The settings are activated.
(OK)
4.
If you are done, press the key.
5.
To return to the Operation mode,
1. Press the key, use the or key to select
key.
2. Press the or key to select
key.
or
, and press the
, and press the
Explanation
Filter
Enable (
Disable (
): Enables the setting of the filter and the time constant in Setting mode.
): The “FILTR” item does not appear in Setting mode.
<Related Topics>
Setting the filter: Section 3.2
4
4-15
IM 04P03B01-01E
4-16
4.12 Enabling the Partial Expanded Recording
Function
The partial expanded recording function can be enabled/disabled. Basic Setting mode cannot be entered when recording is in progress
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Hold down the and keys simultaneously for 3 seconds to display the
Basic Setting mode screen.
3.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Select the “PART.”
(PART)
Select whether to use the partial expanded recording function.
(NOT)
The settings are activated.
(OK)
4.
If you are done, press the key.
5.
To return to the Operation mode,
1. Press the
key.
key, use the or
2. Press the or key to select
key to select
or
key.
, and press the
, and press the
Explanation
Partial Expanded Recording
Enable ( ): Enables the setting of the boundary position and boundary value of the partial expanded recording function in Setting mode.
Disable ( ): The “PART” item does not appear in Setting mode.
<Related Topics>
Setting the partial expanded recording: Section 3.5
IM 04P03B01-01E
4.13 Changing the Printout Font
The printout font can be changed. Basic Setting mode cannot be entered when recording is in progress
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Hold down the and keys simultaneously for 3 seconds to display the
Basic Setting mode screen.
3.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Select “FONT.”
(FONT)
Select the printout font.
(ENG.)
The settings are activated.
(OK)
4.
If you are done, press the key.
5.
To return to the Operation mode,
1. Press the key, use the or key to select
key.
2. Press the or key to select
key.
or
, and press the
, and press the
Explanation
Font
English (
Japanese (
): Uses the alphabet, numbers, and symbols for printout.
): Uses the alphabet, Katakana, numbers, and symbols for printout.
German (
French ( ):
): Uses the German alphabet, numbers, and symbols for printout.
Uses the French alphabet, numbers, and symbols for printout.
* Katakana (Japanese), German, and French can be used in the message printout and tag printout when the respective font is selected.
4
4-17
IM 04P03B01-01E
4-18
4.14 Changing the Print/Display Format of the Date
The format of the printout and display of the year, month, and day can be changed.
Basic Setting mode cannot be entered when recording is in progress
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Hold down the and keys simultaneously for 3 seconds to display the
Basic Setting mode screen.
3.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Select “DATE.”
(DATE)
Select the date format.
(YMD)
The settings are activated.
(OK)
4.
If you are done, press the key.
5.
To return to the Operation mode,
1. Press the key, use the or key to select
key.
2. Press the or key to select
key.
or
, and press the
, and press the
Explanation
Type
Selectable
Settings
Type
Y/M/D
M/D/Y
D/M/Y
D.M.Y
M.D.Y
Printout Format
Example
2006/03/31
03/31/2006
31/03/2006
31.03.2006
Mar.31.2006
Display Format
Example
06 03 31
03 31 06
31 03 06
31 03 06
03 31 06
Notes
Default value
IM 04P03B01-01E
4.15 Enabling the Bias, Low-Cut, and Calibration
Correction Functions
The bias, low-cut, and calibration correction functions can be enabled/disabled. Basic
Setting mode cannot be entered when recording is in progress
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Hold down the and keys simultaneously for 3 seconds to display the
Basic Setting mode screen.
3.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Select “PERS.”
(PERS.)
4
(BIAS)
Bias function
Select enable (USE) or disable (NOT).
(NOT)
(SQRT)
Low-cut function of the channel on which square root computation is assigned
Select enable (USE) or disable (NOT).
(USE)
(1-5V)
Low-cut function of the channel on which 1-5V signal is assigned
Select enable (USE) or disable (NOT).
(NOT)
(CALIB)
Calibration correction function
(Models with the /CC1 option)
Select enable (USE) or disable (NOT).
(NOT)
The settings are activated.
(OK)
4.
If you are done, press the key.
5.
To return to the Operation mode,
1. Press the key, use the or key to select
key.
2. Press the or key to select
key.
or
, and press the
, and press the
4-19
IM 04P03B01-01E
4.15 Enabling the Bias, Low-Cut, and Calibration Correction Functions
Explanation
Bias
Enable (
Disable (
): Enables the setting of the bias value in Setting mode.
): The “BIAS” item does not appear in Setting mode.
SQRT Low-Cut
Sets the low-cut function for the square root computation.
Enable ( ): Enables the setting of the low-cut function when a channel is set to square root computation in Setting mode.
Disable ( ): The “SQRT” item does not appear in Setting mode.
1-5V Low-Cut
Sets the low-cut function for the 1-5V input.
Enable ( ): Enables the setting of the low-cut function when a channel is set to 1-
5V in Setting mode.
Disable ( ): The “1-5V” item does not appear in Setting mode.
Calibration Correction (/CC1 Option)
Enable ( ): Enables the setting of the calibration correction function in Basic
Disable (
Setting and Setting modes.
): The “CALIB” item does not appear in Basic Setting or Setting mode.
Note
The bias and calibration correction functions (/CC1 option) cannot be enabled simultaneously.
<Related Topics>
Setting the bias value: Section 3.10
Setting the low-cut function: Section 2.1
Setting the calibration correction function: Section 4.19
Performing calibration correction: Section 3.11
4-20
IM 04P03B01-01E
4.16 Changing the Time Printout Format
The time printout format can be changed on the alarm printout, message printout, recording start printout, and new chart speed printout. Basic Setting mode cannot be entered when recording is in progress
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Hold down the and keys simultaneously for 3 seconds to display the
Basic Setting mode screen.
3.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
If you press the key, the operation is cancelled, and the display returns to a higher level menu.
Select “T_PRN.”
(T_PRN)
4
Alarm printout
Select the time printout format.
(ALARM)
(HM)
(MSG)
Message printout
Select the time printout format.
(HM)
(RCD)
(HM)
Recording start printout
Select the time printout format.
(SPEED)
New chart speed printout
Select the time printout format.
(HM)
The settings are activated.
(OK)
4.
If you are done, press the key.
5.
To return to the Operation mode,
1. Press the key, use the or key to select
key.
2. Press the or key to select
key.
or
, and press the
, and press the
4-21
IM 04P03B01-01E
4.16 Changing the Time Printout Format
Explanation
Selecting the Printout Format
Select the time format of the alarm printout, message printout, recording start printout, and new chart speed printout.
• Alarm Printout, Recording Start Printout, and New Chart Speed Printout
H:M (
H:M:S (
):
):
Hour:Minute
Hour:Minute:Second
M/D H:M (
M/D H:M:S (
Y/M/D H:M:S (
): Month/Day Hour:Minute
): Month/Day Hour:Minute:Second
): Year/Month/Day Hour:Minute:Second
• Message Printout
H:M ( ):
H:M:S (
M/D H:M (
):
):
M/D H:M:S (
Y/M/D H:M:S (
NONE ( ):
Hour:Minute
Hour:Minute:Second
Month/Day Hour:Minute
): Month/Day Hour:Minute:Second
): Year/Month/Day Hour:Minute:Second
Does not print the date/time.
Note
The printout format of the year, month, and day varies depending on the print/display format of the date (see section 4.14).
4-22
IM 04P03B01-01E
4.17 Initializing the Settings
The recorder settings can be initialized to their factory default.
Be careful, because all settings except the date/time setting in the recorder will be initialized. Basic Setting mode cannot be entered when recording is in progress
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Hold down the and keys simultaneously for 3 seconds to display the
Basic Setting mode screen.
3.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
If you press the key, the operation is cancelled, and the display returns to a higher level menu.
Select “INIT.”
(INIT)
Select the range to be initialized.
(SETUP)
(NO)
Select “YES” and press to execute the initialization and return to Operation mode.
Explanation
Initialization
Set (
Setup (
): Initializes the settings in Setting mode.
): Initializes the settings in Basic Setting mode and Setting mode.
Items That Are Not Initialized
The following items are not initialized.
• Adjustment value of the pen position and the adjustment value of the printer carriage position (Basic Setting mode)
• Date/Time (Setting mode)
4
4-23
IM 04P03B01-01E
4-24
4.18 Assigning Functions to the Remote Control
Input Terminals (/R1 Option)
Functions can be assigned to the remote control input terminals. Basic Setting mode cannot be entered when recording is in progress
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Hold down the and keys simultaneously for 3 seconds to display the
Basic Setting mode screen.
3.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
If you press the key, the operation is cancelled, and the display returns to a higher level menu.
Select “REM.”
(REM)
Select the remote control terminal number.
(REM1)
Select the function to be assigned.
(RCD)
Remote control terminal number
The settings are activated.
(OK)
4.
Press the key to set other remote numbers.
If you are done, press the key.
5.
To return to the Operation mode,
1. Press the
key.
key, use the or
2. Press the or key to select
key to select
or
key.
, and press the
, and press the
Explanation
Remote Numbers
The remote control input terminal numbers are from 1 to 5.
Functions to Be Assigned
RCD (
C_SPD (
):
):
Starts/stops recording.
Changes the chart speed.
T_ADJ (
M_PRN (
MSG1 (
MSG2 (
MSG3 (
MSG4 (
MSG5 (
NONE (
):
):
):
):
):
):
):
):
Adjusts the internal clock to the nearest hour.
Executes a manual printout.
Prints message 1.
Prints message 2.
Prints message 3.
Prints message 4.
Prints message 5.
No function is assigned.
<Related Topics>
Setting the secondary chart speed: Section 3.9
IM 04P03B01-01E
4.19 Setting the Calibration Correction Function
(/CC1 Option)
The calibration correction method and the number of correction points can be set. Basic
Setting mode cannot be entered when recording is in progress
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Hold down the and keys simultaneously for 3 seconds to display the
Basic Setting mode screen.
3.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Select “CALIB.”
(CALIB)
Select the channel number.
(CH1)
(REVIS)
Channel number
Select whether to perform calibration correction using revise values or absolute values.
Set the number of calibration correction points.
The settings are activated.
(OK)
4.
Press the key to set other channels.
If you are done, press the key.
5.
To return to the Operation mode,
1. Press the key, use the or key to select
key.
2. Press the or key to select
key.
or
, and press the
, and press the
Explanation
Calibration Correction Method
Revise value ( ): Specifies the difference between the correction values
Absolute value ( and input values.
): Specifies the correction values.
Number of Correction Points
Selects the number of points that make up the segments (including the start and end points) in the range of 2 to 16.
<Related Topics>
Enabling the calibration correction function: Section 4.15
Performing calibration correction: Section 3.11
4-25
IM 04P03B01-01E
4
4-26
4.20 Selecting the Menus to Be Hidden in Setting
Mode
You can select the menu items to be hidden in Setting mode. Basic Setting mode cannot be entered when recording is in progress
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Hold down the and keys simultaneously for 3 seconds to display the
Basic Setting mode screen.
3.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Select “S.MENU.”
(S.MENU)
Select “SET.”
(SET)
(RANGE)
(ON)
Select whether to display RANGE in
Setting mode. Select ON or OFF.
(BIAS) Select whether to display BIAS in
Setting mode. Select ON or OFF.
(ON)
(ALARM)
(ON)
Select whether to display ALARM in Setting mode. Select ON or OFF.
(UNIT)
(ON)
(CHART)
(ON)
To the next page
Select whether to display UNIT in
Setting mode. Select ON or OFF.
Select whether to display CHART in Setting mode. Select ON or OFF.
IM 04P03B01-01E
Explanation
4.20 Selecting the Menus to Be Hidden in Setting Mode
From the previous page
(AUX)
Select whether to display AUX in
Setting mode. Select ON or OFF.
(ON)
(CALIB)
(Models with the /CC1 option)
Select whether to display CALIB in
Setting mode. Select ON or OFF.
(ON)
The settings are activated.
(OK)
4.
If you are done, press the key.
5.
To return to the Operation mode,
1. Press the key, use the or key to select
key.
2. Press the or key to select
key.
or
, and press the
, and press the
ON (
OFF (
): Shows the menu in Setting mode.
): Hides the menu in Setting mode when customized menu is enabled.
<Related Topics>
Enabling the customized menu: Section 4.22
4
IM 04P03B01-01E
4-27
4-28
4.21 Selecting the FUNC Key Menus to Be Hidden
Procedure
You can select the FUNC key menu items to be hidden. Basic Setting mode cannot be entered when recording is in progress
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Hold down the and keys simultaneously for 3 seconds to display the
Basic Setting mode screen.
3.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
If you press the key, the operation is cancelled, and the display returns to a higher level menu.
Select “S.MENU.”
(S.MENU)
Select “FUNC.”
(FUNC)
(M_PRN)
(ON)
Select whether to display the manual printout FUNC key. Select ON or OFF.
(SLIST) Select whether to display the setup list
FUNC key. Select ON or OFF.
(ON)
(MSG)
Select whether to display the message
FUNC key. Select ON or OFF.
(ON)
(B_CLR)
Select whether to display the buffer clear FUNC key. Select ON or OFF.
(ON)
The settings are activated.
(OK)
4.
If you are done, press the key.
5.
To return to the Operation mode,
1. Press the key, use the or key to select
key.
2. Press the or key to select
key.
or
, and press the
, and press the
IM 04P03B01-01E
Explanation
4.21 Selecting the FUNC Key Menus to Be Hidden
ON(
OFF(
): Shows the FUNC key menu.
): Hides the FUNC key menu when customized menu is enabled.
<Related Topics>
Enabling the customized menu: Section 4.22
4
IM 04P03B01-01E
4-29
4-30
4.22 Enabling/Disabling the Customized Menu
The following operations are carried out when the customized menu is enabled.
• Locks Basic setting mode.
• Hides specified FUNC key menu items.
• Hides specified menu items in Setting mode.
Basic Setting mode cannot be entered when recording is in progress
Procedure
Enabling the Customized Menu
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Hold down the and keys simultaneously for 3 seconds to display the
Basic Setting mode screen.
3.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
For the procedure on how to enter values or characters, see page 18 in the
Operation Guide
.
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Select “CUST.M.”
(CUST.M)
(USE)
Password
(****)
Select whether to enable (USE) the customized menu.
(Displays the following when the customized menu is set to USE)
Set the password.
(P_ADJ)
Select whether to use pen/dot printing position adjustment without the password. Select ON or OFF.
(ON)
The settings are activated.
(OK)
4.
If you are done, press the key.
5.
To return to the Operation mode,
1. Press the
key.
key, use the or
2. Press the or key to select
key.
key to select
or
, and press the
, and press the
IM 04P03B01-01E
IM 04P03B01-01E
4.22 Enabling/Disabling the Customized Menu
Disabling the Customized Menu
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Hold down the and keys simultaneously for 3 seconds to display the
Basic Setting mode screen.
3.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
For the procedure on how to enter values or characters, see page 18 in the
Operation Guide .
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Select “LOCK.”
(LOCK)
Enter the password.
(****)
Enter Basic Setting mode.
Select “CUST.M.”
(CUST.M)
Select NOT.
(NOT)
The settings are activated.
(OK)
4.
If you are done, press the key.
5.
To return to the Operation mode,
1. Press the key, use the or key to select
key.
2. Press the or key to select
key.
or
, and press the
, and press the
4
4-31
4.22 Enabling/Disabling the Customized Menu
Explanation
Enable (
Disable (
): Locks Basic Setting mode and hides the specified menu items in
Setting mode and FUNC key menu items.
): Releases Basic Setting mode and shows the all menu items in Setting mode and all FUNC key menu items.
Password
This is the password used to release the customized menu or to enter Basic Setting mode. Set the password using a four-digit number.
Note
Changing the Settings without Releasing the Basic Setting Mode Lock
The settings in Basic Setting mode can be changed without releasing the customized menu.
Procedure
1. Enter the password in the same manner as described in “Releasing the Customized Menu,” and press the key.
2. Enter Basic Setting mode.
3. Change the settings in the same manner as the normal procedure.
4. Return to Operation mode with the customized menu enabled.
<Related Topics>
Selecting the FUNC key menus to be hidden: Section 4.21
Selecting the menus to be hidden in Setting mode: Section 4.20
Adjusting the pen/dot position: Sections 6.4 and 6.5
4-32
IM 04P03B01-01E
4.23 Changing the Temperature Unit
The unit of the temperature measured using the TC or RTD can be changed. Basic
Setting mode cannot be entered when recording is in progress
Procedure
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
2.
Hold down the and keys simultaneously for 3 seconds to display the
Basic Setting mode screen.
3.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
If you press the higher level menu.
key, the operation is cancelled, and the display returns to a
Select “TEMP.”
(TEMP)
Selects the temperature unit.
(DEG_C)
The settings are activated.
(OK)
4.
If you are done, press the key.
5.
To return to the Operation mode,
1. Press the key, use the or key to select
key.
2. Press the or key to select
key.
or
, and press the
, and press the
Explanation
Temperature Unit
°C (
°F (
): Uses Celsius.
): Uses Fahrenheit.
4
4-33
IM 04P03B01-01E
Chapter 5 Troubleshooting
5.1
A List of Error Messages
There are cases in which the LED displays an error code during operation. The error messages and their description are listed below.
Setting Errors
012
013
021
022
023
024
008
009
010
011
004
005
006
007
Code Message Sent via Communication
001 System error.
002
003
Incorrect date or time setting.
A disabled channel is selected.
Incorrect function parameter.
The input numerical value exceeds the set range.
Incorrect input character string.
Too many characters.
Explanation/Countermeasures
Contact your nearest YOKOGAWA dealer.
Check the setting.
The channel does not exist.
Incorrect communication parameter.
–
The entered character cannot be used.
–
Incorrect input mode.
Incorrect input range code.
Format error.
Range settings are not same within the selected channels.
An invalid characters.
Ref. CH error.
Incorrect range mode (Volt, TC, Scale, etc.) setting.
Incorrect range type (2 V, R, PT100, etc.) setting.
Incorrect character string format.
Channels whose range differs cannot be set simultaneously.
Cannot set an alarm for a SKIPPED channel.
The upper and lower span limits are equal.
Contains an invalid character.
Specify a channel whose range is set to voltage, TC, or RTD for the reference channel.
–
This is not allowed.
The upper and lower scale limits are equal.
This is not allowed.
The lower span limit is greater than the upper span – limit.
025
026
027
030
031
035
036
037
038
039
040
041
042
048
049
The lower scale limit is greater than the upper scale – limit.
Bias cannot be set to the SKIPPED channel.
Bias cannot be set to the DI channel.
–
–
The partial boundary value exceeds the range of the – span.
Partial is invalid on the SKIPPED channel.
The upper and lower limits of the printing zone are equal.
–
Set the rightmost value of the zone – the leftmost value ≥ 5 mm.
The lower limit of the printing zone is greater than the upper limit.
The printing zone is narrower than the minimum width (5 mm).
Partial is invalid on the DI channel.
The bias and the calibration cannot be used simultaneously.
Datume value (1 >= 2)
–
–
Set the rightmost value of the zone – the leftmost value ≥ 5 mm.
Set the rightmost value of the zone – the leftmost value ≥ 5 mm.
Datume value (n-1 > n)
Revise value (n-1 >= n)
Start = Finish.
Invalid or missing DST time settings.
Set the measured value of the first point less than that of the second point in the calibration correction.
Set the measured value of the n–1 th
point less than or equal to that of the n th
point in the calibration correction.
Set the correction value of the n–1 th
point less than that of the n th point in the calibration correction.
The DST start time and end time cannot be set to the same time.
Since the time gains one hour when the DST starts, the set-up time does not exist.
5-1
IM 04P03B01-01E
5
5.1 A List of Error Messages
161
163
164
165
166
167
169
091
100
101
102
103
Code Message Sent via Communication
081 All space or ‘quit’ string cannot be specified.
086
087
The key-lock release password is incorrect.
This key is locked.
Password is incorrect.
IP address doesn’t belong to class A, B, or C.
Explanation/Countermeasures
–
Enter the correct password.
–
Enter the correct password.
–
The result of the masked IP address is all 0s or 1s.
–
SUBNET mask is incorrect.
The net part of default gateway is not equal to
that of IP address.
Set a correct subnet mask.
Set the correct default gateway.
This action is invalid during pen hold.
This action is invalid during record.
This action is invalid during manual printing.
This action is invalid during list printing.
This action is invalid during setup list printing.
This action is invalid during chart feed.
This action is invalid during ribbon hold.
–
–
–
–
–
–
–
Operation Errors
Code Message Sent via Communication
232 There is no available data.
Explanation/Countermeasures
There is no data for periodic printout or data for calculating TLOG when the timer expired.
Communication Errors
394
395
396
397
390
391
392
393
Code Message Sent via Communication
300 Command is too long.
301
302
303 Data request command can not be enumerated with – sub-delimiter.
Explanation/Countermeasures
–
Too many number of commands delimited with ’;’.
Keep the number of commands separated by sub delimiters under 10.
This command has not been defined.
–
350
351
352
353
Command is not permitted to the current user level.
This command cannot be specified in the current mode.
The option is not installed.
This command cannot be specified in the current setting.
–
–
–
–
Command error.
Delimiter error.
Parameter error.
No permission.
No such connection.
Use “quit” to close this connection.
Failed to disconnect.
No TCP control block.
–
–
–
–
–
Attempted to disconnect its own connection.
–
The control block of the specified connection cannot be found.
5-2
IM 04P03B01-01E
5.1 A List of Error Messages
403
404
420
421
Code Message Sent via Communication
400
401
402
422
Input username.
Input password.
Select username from ‘admin’ or ‘user’.
Login incorrect, try again!
–
No more login at the specified level is acceptable.
–
Connection has been lost.
–
The number of simultaneous connection has been – exceeded.
Communication has timed-out.
–
Explanation/Countermeasures
–
–
If the recorder is configured not to use the user name and password, use user names ‘admin’ or ‘user’.
Warning Messages
Code Message Sent via Communication
600 Initialized.
System Errors
930
940
950
951
960
961
962
963
964
965
966
Code Message Sent via Communication
902 RAM failure.
910
921
922
A/D error.
A/D calibration value error.
A/D calibration is in the wrong order.
Memory acquisition failure.
The ethernet module is down.
A/D number error.
EEPROM write error.
Ribbon error
Printer error
Plotter error
Pen 1 error
Pen 2 error
Pen 3 error
Pen 4 error
Explanation/Countermeasures
Settings and measured data have been initialized.
Explanation/Countermeasures
Contact your nearest YOKOGAWA dealer.
Contact your nearest YOKOGAWA dealer.
Contact your nearest YOKOGAWA dealer.
Contact your nearest YOKOGAWA dealer.
Contact your nearest YOKOGAWA dealer.
Contact your nearest YOKOGAWA dealer.
Contact your nearest YOKOGAWA dealer.
Contact your nearest YOKOGAWA dealer.
Contact your nearest YOKOGAWA dealer.
Contact your nearest YOKOGAWA dealer.
Contact your nearest YOKOGAWA dealer.
Contact your nearest YOKOGAWA dealer.
Contact your nearest YOKOGAWA dealer.
Contact your nearest YOKOGAWA dealer.
Contact your nearest YOKOGAWA dealer.
5
IM 04P03B01-01E
5-3
5-4
5.2
Troubleshooting Flow Charts
Follow the flow charts to correct the problem.
Nothing works (pen and chart paper do not move).
Is the power switch turned ON? Does the switch work properly?
YES
NO
Turn ON the power properly.
See “Power Supply Wiring” in the Operation Guide.
Is the power supply connected properly?
YES
NO
Connect properly.
See “Power Supply Wiring” in the Operation Guide.
Is the power supplied properly?
YES
NO
Supply the power at the specified voltage and frequency.
Contact your nearest
YOKOGAWA dealer.
• The reading error is large.
• The indication is unstable.
• The pen is off the scale on either the 0% or 100% side.
Does the input meet the specifications?
YES
Are the span and range settings correct?
YES
To the next page
NO
NO
Change the input to meet the specifications.
Adjust the span and range.
IM 04P03B01-01E
IM 04P03B01-01E
5.2 Troubleshooting Flow Charts
F rom the previous page
YES
Is the input free of noise?
YES
Is the environmental temperature kept constant?
YES
Is the input wiring correct?
YES
Is the input wiring parallel with other e q uipment?
YES
NO
NO
NO
NO
• Separate the input wiring from the noise source.
• Ground the recorder properly.
• Ground the measured object properly.
• Insulate the TC from the measured object.
• Use shielded cables for input.
Select the integration time of the A/D converter
(See section 4.2).
• Use input filter (pen model: see sections 4.11 and
3.2), moving average (dot model: see sections
4.10 and section 3.3).
• Attach the input terminal cover properly.
• Protect the input terminal from wind or fans.
• Keep the temperature fluctuation near the input
terminal to a minimum.
• Wire correctly (See “Input Signal Wiring” in the
Operation Guide
.).
• Install the terminal block correctly.
• F asten the terminal screws correctly.
• Insulate the R TD from ground.
• If burnt, replace the TC.
• Stop the TC burnout upscale/
downscale function of other e q uipment.
• Ground the recorder and other e q uipment at the
same grounding pole.
• Disconnect parallel wiring.
(Use a double
element TC, for instance.)
Is the RJ C setting correct (TC input)?
YES
Is the pen position and dot printing position adjustment correct?
YES
Contact your nearest
YOKOGAWA dealer.
NO
Set correctly.
Section 4.4
NO
Adjust the pen position or dot printing position
Section
6
.4
Section
6
.
5
5
5-5
5.2 Troubleshooting Flow Charts
Display and other functions do not work properly.
Is the input free of noise?
YES
NO
• Separate the input and
communication wiring from the
noise source.
• Ground the recorder properly.
• Use shielded cables for input and
communication wiring.
• Insert an isolation transformer
into the power line.
• Insert a power line filter into the
power line.
• If an inductive load is connected
to an alarm contact output, use a
surge suppresser on that line.
Contact your nearest
YOKOGAWA dealer.
Keys do not work.
Is the key lock released?
YES
Contact your nearest
YOKOGAWA dealer.
NO
Release the key lock using the
FUNC key
(See “Activating/Releasing the Key Lock.”).
• Some of the menus are not displayed.
• Unable enter Basic Setting mode.
Is the customize menu released?
YES
Contact your nearest
YOKOGAWA dealer.
NO
Release the hiding of the menu items using keys.
Section 4.22
5-6
IM 04P03B01-01E
Chapter 6 Maintenance
6.1
Periodic Inspection
Check the operation periodically to keep the recorder in good working order.
Perform the following checks and replace worn parts as needed.
• Is the indication and recording functioning properly? If not, see chapter 5.
• Are recorded lines or printed characters clear (not blurred)?
On the pen model, replace the felt pens and plotter pens. On the dot model, replace the ribbon cassette. For the procedure, see “Preparing to Record” in the Operation
Guide.
• Is the chart paper feeding properly (no paper jams)? If not, see chapter 5.
• Is there enough chart paper remaining?
Remaining chart length is printed on the left margin of the chart at intervals of 20 cm.
For the replacement procedure of the chart paper, see “Preparing to Record” in the
Operation Guide .
6
Remaining amount of chart paper
6-1
IM 04P03B01-01E
6-2
6.2
Cleaning the Recorder
CAUTION
• When cleaning, be sure not to scratch the flexible printed circuit board of the plotter carriage.
• Do not apply lubricating oil to the shaft.
Pen Model
To maintain smooth operation, it is recommended that the plotter carriage shaft be cleaned once a year.
Cleaning Procedure
Wipe the dust off the plotter carriage shaft using a soft lint-free cloth or paper.
If the dirt does not come off easily, apply ethyl alcohol to the cloth or paper.
Dot Model
To maintain smooth operation, wipe the dust off the two shafts of the printer carriage using a soft lint-free cloth or paper. It is recommended that these shafts be cleaned once a year.
IM 04P03B01-01E
6.3
Calibrating the Recorder
Calibrate the measured value against the input.
It is recommended that the recorder be calibrated once a year to assure its measurement accuracy.
For details regarding calibration, contact your nearest YOKOGAWA dealer.
Required Instruments
A calibration instrument with appropriate resolution is required for calibrating the recorder.
Recommended Instrument
• DC voltage standard: Model 5520A by FLUKE or equivalent
Main Specifications
Output accuracy: ±(0.005% + 1 µV)
• Decade resistance box: Yokogawa Meters & Intruments Model 2793-01 or equivalent
Main Specifications
Accuracy of output range 0.1 to 500 Ω: ±(0.01% + 2 mΩ)
Resolution: 0.001 Ω
• 0°C standard temperature device: ZC-114/ZA-10 by Coper Electronics or equivalent
Main Specifications
Standard temperature stability accuracy: ±0.05°C
For information on purchasing the calibration instruments, contact your nearest
YOKOGAWA dealer.
Calibration Procedure
1.
Wire the recorder and the calibration instrument as shown in the following figure, and adequately warm up the instruments (the warm-up time of the recorder is at least 30 minutes).
2.
Check that the operating environment such as ambient temperature and humidity is within the normal operating conditions (see section 7.6).
3.
Apply appropriate input signals corresponding to 0%, 50%, and 100% of the input range and calculate the errors from the readings.
If the error is outside the accuracy specifications, contact your nearest
YOKOGAWA dealer.
Note
For thermocouple inputs, you must measure the temperature of the input terminal and apply a voltage taking into account the reference junction temperature.
DC Voltage Measurement
– +
+
–
DC voltage standard
6
Input terminals
6-3
IM 04P03B01-01E
6.3 Calibrating the Recorder
Temperature Measurement When Using an RTD
The resistance of three lead wires must be equal.
/b
−
/B +/A
Decade resistance box
(Model 2793-01 from
Yokogawa Meters & Instruments)
Input terminals
Temperature Measurement When Using a Thermocouple
Copper wires Thermocouple wires or TC extension wires
−
+
6-4
+
–
DC voltage standard
Copper wires
Thermocouple wires Input terminals
(0
°
C standard temperature device ZC-114/ZA-10 by Coper Electronics)
RJC of TC input
As the measurement terminal of the recorder is generally at room temperature, the actual output of the thermocouple is different from the values given on the thermoelectromotive force table based on 0°C. The recorder performs compensation by measuring the temperature at the input terminal and adding the corresponding thermoelectromotive force to the actual output of the thermocouple. Therefore, when the measurement terminal is shorted (equivalent to the case when the detector tip is 0°C), the measured value indicates the temperature of the input terminal.
When calibrating the recorder, this compensation voltage (thermoelectromotive force of
0°C reference corresponding to the input terminal temperature) must be subtracted from the output of the DC voltage standard before application. As shown in the figure, by using the 0°C standard temperature device to compensate the reference junction at 0 °C, you can input the thermoelectromotive force of 0 °C reference from the DC voltage standard and perform the calibration.
IM 04P03B01-01E
6.4
Adjusting the Pen Position (Pen Model)
The pen position on the chart paper can be adjusted.
It is recommended that the position be adjusted once a year to assure its recording accuracy.
Note
Pen position is adjusted under standard operating conditions when the recorder is shipped from the factory. Because the chart paper may expand or contract depending on the environment in which the recorder is used, it is recommended that the position be readjusted before use.
Procedure
1.
Warm up the recorder for at least 30 minutes.
2.
Check that the operating environment such as ambient temperature and humidity is within the standard operating conditions (see section 7.6).
3.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
4.
Hold down the and keys simultaneously for 3 seconds to display the
Basic Setting mode screen.
5.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
For the procedure on how to enter values or characters, see page 18 in the
Operation Guide .
To change the polarity, press the or key when the leftmost digit of the value is blinking.
If you press the key, the operation is cancelled, and the display returns to a higher level menu.
6.
Adjust the zero position first and then the full position.
Increase or decrease the setting to align pen position with the scale line on the chart paper.
Select “P_ADJ.”
(P_ADJ)
Select the zero position (ZERO) or full position (FULL).
(ZERO)
Select the pen number.
(PEN1)
Enter the adjustment value.
6
The adjustment value is activated.
(OK)
7.
To repeat the setup, press the
If you are done, press the
key.
key.
8.
To return to the Operation mode,
1. Press the key, use the or key to select
key.
2. Press the or key to select
key.
or
, and press the
, and press the
6-5
IM 04P03B01-01E
6.4 Adjusting the Pen Position (Pen Model)
Explanation
Zero position (
Full position (
to
): Left edge of the chart paper
): Right edge of the chart paper
: Pen number 1 to 4
Adjustment
Zero position: 00 to 70, full position: –45 to 15
A value change of 1 corresponds to 0.033 mm change in the pen position. Decreasing the value moves the pen to the left and increasing the value moves the pen to the right.
Note
The procedure is different when the customized menu is enabled.
• When “P-ADJ” of the customized menu is ON
Carry out steps 1 to 4 in “Adjusting the Pen Position.”
Select “FREE” and press the key to display “P-ADJ.”
Carry out the steps beginning with 5 in “Adjusting the Pen Position.”
• When “P-ADJ” of the customized menu is OFF
See “Releasing the Customized Menu” or “Changing the Settings without Releasing the
Basic Setting Mode Lock.”
<Related Topics>
Releasing the customized menu: Section 4.22
Changing the settings without releasing the basic setting mode lock: Section 4.22
6-6
IM 04P03B01-01E
6.5
Adjusting the Dot Printing Position (Dot Model)
The dot printing position on the chart paper can be adjusted. Adjust the hysteresis, the zero position, and then the full position.
It is recommended that the position be adjusted once a year to assure its recording accuracy.
Note
Dot printing position is adjusted under standard operating conditions when the recorder is shipped from the factory. Because the chart paper may expand or contract depending on the environment in which the recorder is used, it is recommended that the position be readjusted before use.
Procedure
1.
Warm up the recorder for at least 30 minutes.
2.
Check that the operating environment such as ambient temperature and humidity is within the standard operating conditions (see section 7.6).
3.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
4.
Hold down the and keys simultaneously for 3 seconds to display the
Basic Setting mode screen.
5.
Carry out the procedure shown in the figure below.
Press the or key to select the value.
For the procedure on how to enter values or characters, see page 18 in the
Operation Guide
.
To change the polarity, press the or key when the leftmost digit of the value is blinking.
If you press the higher level menu.
6.
Hysteresis:
key, the operation is cancelled, and the display returns to a
Increase or decrease the setting so that the center line on the chart paper becomes a single straight line.
Zero and full positions: Increase or decrease the setting to align the line with the scale line on the chart paper.
Select “P_ADJ.”
(P_ADJ)
Select hysteresis (HYS), zero position
(ZERO), or full position (FULL).
(HYS)
Enter the adjustment value.
6
The adjustment value is activated.
(OK)
7.
If you are done, press the key.
8.
To return to the Operation mode,
1. Press the key, use the or key to select
key.
2. Press the or key to select
key.
or
, and press the
, and press the
6-7
IM 04P03B01-01E
6.5 Adjusting the Dot Printing Position (Dot Model)
Explanation
Hysteresis (
Zero position (
Full position (
): Center of the chart paper
): Left edge of the chart paper
): Right edge of the chart paper
Hysteresis Adjustment
Adjustment: –7 to 7
A line is drawn at the center of the chart paper. If the line appears as shown in Figure a, increase the displayed setting. If the line appears as shown in Figure b, decrease the displayed setting.
Repeat this procedure until the line becomes straight.
A value change of 1 corresponds to 0.1 mm change in the dot printing position.
Up Up
Down Down
Figure a Figure b
Zero Position and Span Adjustment
Adjustment
Zero position: 00 to 15, full position: –45 to 15
A value change of 1 corresponds to 0.1mm change in the dot printing position.
Decreasing the value moves the line to the left and increasing the value moves the line to the right.
Note
The procedure is different when the customized menu is enabled.
• When “P-ADJ” of the customized menu is ON
Carry out steps 1 to 4 in “Adjusting the Dot Printing Position.”
Select “FREE” and press the key to display “P-ADJ.”
Carry out the steps beginning with 5 in “Adjusting the Dot Printing Position.”
• When “P-ADJ” of the customized menu is OFF
See “Releasing the Customized Menu” or “Changing the Settings without Releasing the
Basic Setting Mode Lock.”
<Related Topics>
Releasing the customized menu: Section 4.22
Changing the settings without releasing the basic setting mode lock: Section 4.22
6-8
IM 04P03B01-01E
Chapter 7 Specifications
7.1
Input Specifications
Number of Inputs and Scan Interval on the Pen Model
Item
Number of inputs
Scan interval
Specifications
1, 2, 3, or 4
125 ms
Number of Inputs and Scan Interval on the Dot Model
Item
Number of inputs
Scan interval
Specifications
6
1 s (when the integration time of the A/D converter is 20 ms or 16.7 ms)
2.5 s (when the integration time of the A/D converter is 100 ms)
Input Type
Item
Input type
Specifications
DC voltage, 1-5V, TC, RTD, DI (ON/OFF input), DC current (by adding an external shunt resistor)
Input Range and Measurable Range
Input
Volt
TC
RTD
Range Type
E
1
J
1
T
1
N
1
R
1
S
1
B
1
K
1
W
2
L
3
U
3
WRe
4
20 mV
60 mV
200 mV
2 V
6 V
20 V
50 V
1-5V
PT (Pt100)
5
JPT (JPt100)
5
Measurable Range
–20.00 to 20.00 mV
–60.00 to 60.00 mV
–200.0 to 200.0 mV
–2.000 to 2.000 V
–6.000 to 6.000 V
–20.00 to 20.00 V
–50.00 to 50.00 V
(0.800 to 1.200 V range) to (4.800 to 5.200 V range)
0.0 to 1760.0°C
0.0 to 1760.0°C
0.0 to 1820.0°C
−200.0 to 1370.0°C
−200.0 to 800.0°C
−200.0 to 1100.0°C
−200.0 to 400.0°C
0.0 to 1300.0°C
0.0 to 2315.0°C
−200.0 to 900.0°C
−200.0 to 400.0°C
0.0 to 2400.0°C
32 to 3200°F
32 to 3200°F
32 to 3308°F
−328 to 2498°F
−328.0 to 1472.0°F
−328.0 to 2012.0°F
−328.0 to 752.0°F
32 to 2372°F
32 to 4199°F
−328.0 to 1652.0°F
−328.0 to 752.0°F
32 to 4352°F
–200.0 to 600.0°C
–200.0 to 550.0°C
−328.0 to 1112.0°F
−328.0 to 1022.0°F
0: Less than 2.4 V, 1: Greater than or equal to 2.4 V
0: Open, 1: Closed
DI Level
Contact
1 R, S, B, K, E, J, T, N: IEC584-1 (1995), DIN IEC584, JIS C1602-1995
2 W: W-5% Rd/W-26% Rd (Hoskins Mfg. Co.), ASTM E988
3 L: Fe-CuNi, DIN43710, U: Cu-CuNi, DIN43710
4 WRe: W-3%Re/W-25%Re (Hoskins Mfg Co.)
5 Pt100: JIS C1604-1997, IEC751-1995, DIN IEC751-1996
JPt100: JIS C1604-1989, JIS C1606-1989
Measurement current: i = 1 mA (Pt100, JPt100)
7
7-1
IM 04P03B01-01E
7.1 Input Specifications
Item
Input type
Specifications
Floating unbalanced input.
Isolation between channels (except, b terminal is shared for RTD input).
Burnout Detection of TC Can be set for each channel.
Upscale/Downscale switchable.
Input Type
TC input
1-5V input
Operating Conditions
2 kΩ or less: normal, 10 MΩ or more: burnout, detection current: approx. 10 µA
0.2 V or less: burnout
RJC of TC input Set whether to use the recorder RJC function or an external RJC function for each channel.
Set the compensation voltage when using an external RJC function.
Compensation voltage range: –19999 µV to 20000 µV.
A/D converter
Resolution
Integration time
16 bits
Pen model: Selectable from 20 ms (50 Hz), 16.7 ms (60 Hz), and Auto (auto switch between 20 ms and 16.7 ms according to the power supply frequency).
Dot model: Selectable from 20 ms (50 Hz), 16.7 ms (60 Hz), 100 ms and Auto (auto switch between 20 ms and 16.7 ms according to the power supply frequency).
Filter function (pen model) Filter ON/OFF switchable for each channel.
Time constant selectable from 2, 5, and 10 s.
Moving average function Moving average ON/OFF switchable for each channel.
(dot model) The number of samples of the moving average is selectable between 2 and 16.
Input Computation
Item
Delta computation
Linear scaling
Specifications
Calculates the difference between two channel inputs using the following equation.
Delta = (the input value of the channel set to delta computation) – (the input value of the reference channel) where (reference channel NO.) < (channel No. set to delta computation).
Computable input type: DC voltage, TC, and RTD. The channel set to delta computation and the reference channel is set to the same range type.
Scales the input value to a value with a unit suitable for the application.
Computable input type: DC voltage, TC, RTD, DI
Value after scaling
Mantissa: –19999 to 30000
Decimal position: Can be set arbitrarily
Unit: Can be set arbitrarily (up to 6 characters)
Displayable and printable range
–19999 to 31500
Computation on the 1-5V input
Linear scaling Linearly scales the 1-5V signal.
Value after scaling: Same as linear scaling.
Displayable and printable range: Same as linear scaling.
Low-cut function Sets values below 0% of the recording span to the leftmost value of the scale. The leftmost value of scale must be less than the rightmost value of scale.
Square root computation Takes the square root of the input value and linearly scales the result.
Computable input type: DC voltage
Linear scaling Value after scaling: Same as linear scaling.
Displayable and printable range: Same as linear scaling.
Low-cut function Sets values below the low-cut point to the leftmost value of scale. The leftmost value of scale must be less than the rightmost value of scale.
Low-cut point range: 0.0 to 5.0% of the recording span (0.1% steps)
Bias Adds a bias to the measuring input value.
Bias value range: ±10% of the span of the measurable range at the specified range type.
±10% of the scaling span if linear scaling is used.
7-2
IM 04P03B01-01E
7.2
Alarm Function Specifications
Item
Number of alarms
Alarm type
Hysteresis
Specifications
Up to four alarms (level) for each measurement channels.
High limit (H), low limit (L), difference high limit (h), and difference low limit (l). The symbol indicating the alarm is given in parentheses.
Set a width to the value for detecting alarm occurrence/release (common to all channels and all levels)
Applied to high limit alarm and low limit alarm.
Hysteresis range: Approx. 0.0% to 1.0% of the recording span (0.1% steps)
Display Indicates the alarm occurrence status on the display.
Display for each channel: Displays the alarm type (display precedence: , , , and ).
Alarm summary display: The ALM indicator illuminates.
Alarm relay contact output (optional specifications)
See section 7.5
7
7-3
IM 04P03B01-01E
7-4
7.3
Recording Function Specifications
Trend Recording (Pen Model)
Item
Recording pen
Step response time
Number of pens
Specifications
Disposable felt pen
Approx. 1 s (using the IEC61143 measurement method)
Up to 4
Recording color
Trend recording
Pen 1: Red, pen 2: Green, pen 3: Blue, pen 4: Violet
Updates the data at the scan interval. Continuous recording.
Pen offset compensation Records by compensating for the offset of each pen along the time axis.
Chart speed 10 to 12000 mm/h (40 steps).
Zone recording Recording zone can be specified for each channel.
Recording width: 5 mm or more (1 mm steps)
Partial expanded recording Records by expanding the right or left side of the boundary position (the other section is reduced).
Boundary position: 1 to 99%
Boundary value: Within the recording span range
Trend Recording (Dot Model)
Item
Recording method
Specifications
Trend recording by a 6-color wire dot printer
Recording color Channel 1: Purple, channel 2: Red, channel 3: Green, channel 4: Blue, channel 5: Brown, channel 6: Black
Trend recording interval Records at the following interval through a raster scan system.
AUTO: Synchronizes to the chart speed and automatically sets to the interval
FIX: 10 s/6 channels
Chart speed
Recording ON/OFF
10 to 1500 mm/h (28 steps)
Recording can be turned ON/OFF for each channel.
Zone recording Same as the pen model.
Partial expanded recording Same as the pen model.
Chart Paper
Item
Printing width
Specifications
100 mm
Type/Length Z-fold type. Approx. 16 m.
Chart paper feeding accuracy
Within ±0.1% After feeding 1000 mm and with respect to the print scale on the chart paper.
IM 04P03B01-01E
7.3 Recording Function Specifications
Printouts (Pen Model)
Item
Recording pen (color)
Specifications
Plotter pen (purple)
Alarm printout
Printout contents
Time printout format
Alarm printout buffer
Prints alarm occurrence/release.
Occurrence ( )/release ( ) marks, channel No. or tag, alarm type, alarm level, time, printout buffer overflow mark.
Selectable from hour:minute, hour:minute:second, month:day:hour:minute, month:day:hour:minute:second, and year:month:day:hour:minute:second.
Stores 8 occurrences of alarm information waiting to be printed.
Periodic printout
Interval
Mode
Printout contents
Prints at specified time intervals from the reference time.
Reference time: 00 hour 00 minute to 23 hour 00 minute (1 hour steps, minute fixed)
Auto: Automatically determined from the chart speed.
Manual: Select 10 min, 12 min, 15 min, 20 min, 30 min, 1 hour, 2 hours, 3 hours, 4 hours, 6 hours,
8 hours, 12 hours, or 24 hours.
Select no periodic printout or print instantaneous values.
Date/Time, offset compensation ON/OFF, channel information (measured value, alarm status, unit, delta computation ON/OFF, scale, channel number or tag, recording color), chart speed (with time ticks)
Message printout
Number of messages
Printout contents
Time printout format
Prints preset message strings.
5
Time, message (up to 16 characters), printout buffer overflow mark.
Selectable from hour:minute, hour:minute:second, month:day:hour:minute, month:day:hour:minute:second, year:month:day:hour:minute:second, and not print.
Message printout buffer Stores 5 messages waiting to be printed.
Recording start printout
Printout contents
Time printout format
Prints at the start of recording.
Time and chart speed, printout buffer overflow mark.
Selectable from hour:minute, hour:minute:second, month:day:hour:minute, month:day:hour:minute:second, and year:month:day:hour:minute:second.
New chart speed printout Prints when the chart speed is changed.
Printout contents Chart speed and time, printout buffer overflow mark.
Time printout format Selectable from hour:minute, hour:minute:second, month:day:hour:minute, month:day:hour:minute:second, and year:month:day:hour:minute:second.
Manual printout
Printout contents
Prints the measured values of all channels.
Measured values of all channels at that point.
Trend recording is temporarily suspended.
Setting printout (List)
Printout contents
Prints the settings of items in Setting mode.
Range setting, alarm setting, etc.
Trend recording is temporarily suspended.
Setting printout (setup list) Prints the settings of items in Basic Setting mode.
Printout contents Basic alarm specifications, basic recording specifications, etc.
Trend recording is temporarily suspended.
Items dependent on the chart speed
Chart speed
10 to 1500 mm/h
1800 mm/h or higher
Periodic printout
Alarm printout
Message printout
Recording start printout
New chart speed printout
Printed
Not printed
Date printout format
Chart speed
10 to 15 mm/h
20 to 30 mm/h
40 to 60 mm/h
75 to 120 mm/h
150 to 180 mm/h
200 to 300 mm/h
360 to 1500 mm/h
Periodic printout interval
8 hours
4 hours
2 hours
1 hour
30 minutes
20 minutes
10 minutes
Select the printout format of the date from Y/M/D, M/D/Y, D/M/Y, D.M.Y, and M.D.Y. The format applies to the date printout of all printout items .
7
IM 04P03B01-01E
7-5
7.3 Recording Function Specifications
Printout (Dot Model)
Item
Recording
Channel printout
Alarm printout
Printout contents
Time printout format
Alarm printout buffer
Periodic printout
Interval
Measured value
Printout contents
Specifications
Dot printing.
Prints the channel number beside the trend recording every approx. 25 mm of chart paper.
Channel printout ON/OFF selectable.
Prints alarm occurrence/release.
Occurrence ( , red)/release ( , blue) marks, channel No. or tag, alarm type, alarm level, time, printout buffer overflow mark.
Selectable from hour:minute, hour:minute:second, month day hour:minute, month day hour:minute:second, and month day year hour:minute:second.
Stores 12 occurrences of alarm information waiting to be printed.
Prints at specified time intervals from the reference time.
Same as the pen model.
Same as the pen model.
Same as the pen model except offset compensation ON/OFF and recording color are not printed.
Message printout
Recording start printout
Same as the pen model.
Same as the pen model. With time ticks.
New chart speed printout Same as the pen model. With time ticks.
Manual printout Same as the pen model.
Setting printout (List)
Setting printout (Setup)
Same as the pen model.
Same as the pen model.
Items dependent on the chart speed
Chart speed
Channel printout
10 to 100 mm/h
120 mm/h or higher
Printed
Not printed
Periodic printout
Alarm printout
Message printout
Recording start printout
New chart speed printout
Printed
Not printed
Chart speed
10 to 15 mm/h
20 to 30 mm/h
40 to 75 mm/h
80 to 100 mm/h
Periodic printout interval
8 hours
4 hours
2 hours
1 hour
Date printout format Same as the pen model.
Values for Special Measured Values
Same as “Special values” for the digital display on page 7-7.
7-6
IM 04P03B01-01E
7.4
Display Function Specifications
Display and Displayed Contents
This section explains the specifications of the display functions of measurement channels. Display examples are illustrations used to explain the displayed contents and differ in appearance from the actual displays.
Item
Display
Specifications
7-segment LED (orange)
Number of screens
Displayed contents
Display type
5 (switched using keys)
Digital display and channel ID alarm status display (automatically/manually switch the displayed channel)
Date display
Time display
OFF
Display update of measured values / computed values
When displayed channels are fixed
Dot model: Updated at the scan interval
Pen model: Updated every 1 s
When displayed channels are automatically switched
Switches the channel/alarm status and measured value at 2-s intervals.
Status display
RCD
ALM
Display type specifications
This indicator turns ON when recording is started and turns OFF when stopped.
The indicator turns ON when an alarm occurs and turns OFF when the alarm is released.
Digital display
Channel number (1 st
digit) Displayed with 1 character as follows:
Alarm (2 nd
digit)
Measurement channels: 1, 2, 3, 4, 5, 6
Displayed with the symbols below. If multiple alarms are occurring simultaneously, the alarm with higher precedence is shown.
Measured value (3
(Higher order of precedence) , , , (lower order of precedence) rd
to 7 th
digits)
• DC voltage input: Displays values between “the min. measurable value – 5% of the span of the measurable range” and “the max. measurable value + 5% of the span of the measurable range” of the range (example: –2.200 to 2.200 V for the 2 V range).
• TC and RTD input: Displays values for input values between “the min. measurable value – 10°C” and “the max. measurable value + 10°C” (example: –10.0°C to 1770.0°C for TC R)
• ON/OFF input (DI): Displays the input value 0 or 1.
• Linear scaling (1-5V, scaling, and square root): Displays value for input values between “the leftmost value of scale – 5% of scaling span” and “the rightmost value of scale + 5% of scaling span” (example: –5.0 to 105.0 when scaled to 0.000 to 100.0). However, the displayable range during scaling is from –19999 to 31500 (excluding the decimal). Values below –19999 and values above 31500 are displayed as –Over and +Over, respectively.
7
7-7
IM 04P03B01-01E
7.4 Display Function Specifications
Item
Special values
Date/Time display
Lights off
Name
Digital Display
Date display
Specifications
Measurement channel
Status
+Over
–Over
Skip
Error
+Burnout
–Burnout
Display
OVER
–OVER
SKIP
ERROR
B.OUT
B.OUT
Description
See below.
See below.
A value for channels set to skip.
Values such as when both the reference channel and measurement channel are +Over or –Over in delta computation.
A value displayed when a burnout is detected on a channel set to burnout up scale.
A value displayed when a burnout is detected on a channel set to burnout down scale.
+Over and –Over of measurement channels
A condition in which the value is outside the display range indicated in “Measured value or computed value” above. For example,
• For 2 V range, values below –2.200 V are –Over and values over 2.200 V are +Over.
• For TC R, values below –10.0°C are –Over and values over 1770.0°C are +Over.
• If scaled to 0.0 to 100.0, values below –5.0 are –Over and values above 105.0 are +Over.
However, the displayable range during scaling is from –19999 to 31500 (excluding the decimal).
Values below –19999 and values above 31500 are displayed as –Over and +Over, respectively.
Displays the date or the time.
The date display format can be selected. The format is common with the date printout format.
Displays nothing.
Display Example Description
Channel number. (1 digit), alarm (1 digit), and measured value (5 digits)
Alarm information Measured value
Channel number
Year/Month/Day Displays the lower two digits for the year.
Day
Year
Month/Day/Year
Month
Month
Day/Month/Year
Day
Day
Month
Year
Year
Time display
Hour Minute Second
7-8
IM 04P03B01-01E
7.5
Specifications of Optional Functions
Alarm Output Relay (/A1, /A2, and /A3)
Item
Operation
Number of outputs
Relay contact rating
Output format
Auxiliary functions
Diagnosis output
Specifications
Outputs relay contact signals from the dedicated terminals on the rear panel when alarms occur.
2 outputs (/A1), 4 outputs (/A2), 6 outputs (/A3)
250 VDC/0.1 A (for resistance load)
250 VAC (50/60 Hz)/3 A
NO-C-NC
Energized/De-energized operation selectable (common to all relays)
Reflash operation (Fixed to relay I01, I02, and I03. Relay release time is approx. 500 ms.)
Relay I01 can be used for diagnosis output.
Diagnosis output: Outputs a relay signal when an error in the recording section (plotter on the pen model), a burnout, or an error in the A/D converter is detected. Relay operation is fixed to de-energized.
RS-422A/485 Communication Interface (/C3)
Item
Connection
Connection type
Transmission mode
Synchronization
Baud rate
Start bit
Data length
Stop bit
Parity
Received buffer length
Escape sequence
Protocol
Communication mode
Communication distance
Specifications
Complies with EIA RS-422A/485
Multi-drop connection 1:32 (four-wire system), 1:31 (two-wire system)
Half-duplex
Start-stop synchronization
1200, 2400, 4800, 9600, 19200, or 38400 bps
Fixed to 1 bit
7 bits or 8 bits
Fixed to 1 bit
Odd, even, or none (no parity)
2047 bytes
Open and close
Dedicated protocol, Modbus slave protocol
ASCII for input/output for control and setting
ASCII or binary for input/output of measured data
1.2 km
Ethernet Communication Interface (/C7)
Item Specifications
Function
Setting/Measurement server Uses a dedicated protocol
Maintenance/Test server
Measured/computed data, setup data, status byte
Connection information, network statistics, etc.
Instrument information server Model, serial number, etc.
Electrical and mechanical specifications
Conforms to IEEE 802.3.
Interface Basic specifications
Connection
Protocol
Ethernet (10BASE-T)
TCP, IP, UDP, ICMP, and ARP
The maximum number of simultaneous connections and the number of simultaneous use
Function
Administrators
Setting/Measurement server 3
Maximum Number of Number of
Connections Users Simultaneous Users Port Number
1 2 34260/tcp
Maintenance/Test server
Instrument information server -
1
-
1
-
1 34261/tcp
34264/udp
Miscellaneous
User authentication
Keepalive
Administrator: 1, users: 6 (limitations placed on users)
Drops the connection if there is no response to an inspection packet. Use or not use is selectable.
7-9
7
IM 04P03B01-01E
7.5 Specifications of Optional Functions
Green Display (/D6)
Item
Color
Specifications
1 st
digit (channel display) and 3 rd
to 7 th
digits (data display) of the 7- segment LED: Green
2 nd
digit (alarm display): Orange
Calibration Correction (/CC1)
Item Specifications
Calibration Correction Method
Converts the measured values of the measurement channels to correction values.
Specify using revise values or absolute values.
Number of correction points: 2 to 16 (including the start and end points)
Selectable input ranges DC voltage, TC, RTD, and 1-5V
Cu10, Cu25 RTD Input (/N1)
Item Specifications
Cu10, Cu25 RTD This option allows Cu10 and Cu25 inputs to be added to the standard input types.
Input type and measurable range
Input Type
Cu10 (GE)
Measurable Range
RTD
(Measurement current i: 2 mA)
Cu10 (L&N)
Cu10 (WEED)
Cu10 (BAILEY)
Cu10: α = 0.00392 at 20°C
Cu10: α = 0.00393 at 20°C
Cu25*: α = 0.00425 at 0°C
* Measurement current i = 1 mA
–200 to 300°C
–328.0 to 572.0°F
Measurement and recording accuracy
Input Type
Cu10 (GE)
Cu10 (L&N)
Cu10 (WEED)
Cu10 (BAILEY)
Cu10: α = 0.00392 at 20°C
Cu10: α = 0.00393 at 20°C
Cu25: α = 0.00425 at 0°C
Measurement Accuracy
±(0.4% of rdg + 1.0°C)
±(0.3% of rdg + 0.8°C)
Recording Accuracy
Measurement accuracy
± (0.3% of recording span)
7-10
Expansion Inputs (/N3)
Item
Input type
Specifications
Adds the input types shown in the table below.
Thermocouple
i = 1 mA)
Input Type
PR40-20
PLATINEL
NiNiMo
W/WRe26
Type N (AWG14)
Measurement Range
0.0 to 1900.0
°
C
0.0 to 1400.0
°
C
0.0 to 1310.0
°
C
0.0 to 2400.0
°
C
0.0 to 1300.0
°
C
32 to 3452
32 to 2552
32 to 2390
32 to 4352
32 to 2372
°
°
°
°
°
F
F
F
F
F
Kp vs Au7Fe 0.0 to 300.0 K
RTD
(Measuring current
Pt25 –200.0
°
F
Pt50 –200.0
°
F
Ni100 (SAMA)
Ni100 (DIN)
Ni120
–200.0 to 250.0
°
C
–60.0 to 180.0
°
C
–70.0 to 200.0
°
C
–328.0 to 482.0
–76.0 to 356.0
–94.0 to 392.0
°
°
°
F
F
F
J263*B 0.0 to 300.0 K
Cu53 –50.0 to 150.0
°
C
Cu100:
α
= 0.00425 at 0
°
C
–50.0 to 150.0
°
C
–58.0 to 302.0
–58.0 to 302.0
°
°
F
F
IM 04P03B01-01E
7.5 Specifications of Optional Functions
Item Specifications
Measurement and recording accuracy
Input Type Measurement Accuracy Recording Accuracy
PR40-20 0 to 450
°
C Not
450 to 750
°
C
±
(0.9% of rdg + 3.2
°
C)
750 to 1100
°
C
±
(0.9% of rdg + 1.3
°
C)
1100 to 1900
°
C
±
(0.9% of rdg + 0.4
°
C)
PLATINEL
±
(0.25% of rdg + 2.3
°
C)
NiNiMo
W/WRe26 0 to 400
°
C
±
(0.25% of rdg + 0.7
°
C)
±
15.0
°
C or less
400 to 2400
°
C
±
(0.2% of rdg + 2.0
°
C)
Type N(AWG14)
Kp vs Au7Fe 0 to 20 K
±
(0.2% of rdg + 1.3
°
C) Measurement
±
4.5 K accuracy
20 to 300 K
±
2.5 K
±
(0.3% of
Pt25
±
(0.15% of rdg + 0.6
°
C) recording
Pt50
±
(0.3% of rdg + 0.6
°
C)
Ni100(SAMA)
Ni100(DIN)
±
(0.15% of rdg + 0.4
°
C)
Ni120
J263*B 0 to 40 K
40 to 300 K
±
3.0 K
±
1.0 K
Cu53
±
(0.15% of rdg + 0.8
°
C)
Cu100
±
(0.2% of rdg + 1.0
°
C)
Note) No RJC for PR40-20 (fixed to 0
°
C)
Remote Control 5 Points (/R1)
Item Specifications
Number of input terminals 5
Input type Isolated from the main circuitry through a photocoupler, built-in isolated power supply for the input terminals, and shared common
Input type and signal level
Voltage-free contact
Open collector
Signal type
Operation
Contact closed at 200 Ω or less and contact open at 100 kΩ or greater
ON voltage: 0.5 V or less (sink current 30 mA or more), leakage current when OFF: 0.25 A or less
Edge, level, or trigger (250 ms or more)
Perform the following control operations by applying a given signal to the remote signal input terminal.
• Start/stop recording (edge)
• Set the clock (adjust the clock to the nearest hour with the contact input, trigger)
Time When Signal Is Input Procedure
00 min 00 s to 01 min 59 s Truncates the minutes and seconds. Example: 10:00:50 → 10:00:00
58 min 00 s to 59 min 59 s Rounds up the minutes and seconds. Example: 10:59:50 → 11:00:00
02 min 00 s to 57 min to 59 s No operation
• Manual printout (trigger)
• Message 1 to 5 printout (trigger)
• Switch the chart speed (level)
7
IM 04P03B01-01E
7-11
7.5 Specifications of Optional Functions
24-VDC/AC Power Supply Operation (/P1)
Item Specifications
Rated supply voltage 24 VDC/AC
Allowable power supply voltage range
Withstand voltage
21.6 to 26.4 VDC/AC
1000 VAC at 50/60 Hz for one minute (between the power terminal and the ground terminal)
Rated power supply frequency
50/60 Hz (for AC operation)
Allowable power supply frequency range
50 Hz ± 2% or 60 Hz ± 2% (for AC operation)
Effects of power supply voltage fluctuation
The fluctuation in the measured values is within ±1 digit and that in the recording is within ±0.1% in the recording span for the 21.6 to 26.4 VAC/DC range.
Effects of power supply frequency fluctuation
Rated power
The fluctuation in the measured values and recording is ±(0.1% of rdg + 1 digit) at the rated frequency ±2 Hz.
25 VA (for DC operation) or 35 VA (for AC operation)
Power consumption
Model 24 VDC 24 VAC Maximum
1 to 4 pen models
6 dot model
* When balanced
Approx. 7 VA*
Approx. 8 VA*
Approx. 13 VA*
Approx. 13 VA*
Approx. 35 VA
Approx. 35 VA
7-12
IM 04P03B01-01E
7.6
General Specifications
Construction
Item Specifications
Mounting
Mounting angle
Flush panel mounting (on a vertical plane)
Inclined backward up to 30 degrees from a horizontal plane.
Allowable panel thickness 2 to 26 mm
Material Case: drawn steel
Color
Front panel
Dimensions
Weight
Front door: Aluminum die-cast
Case: Charcoal gray light (Munsell 10B3.6/0.3 or equivalent)
Front door: Charcoal gray light (Munsell 10B3.6/0.3 or equivalent)
Water and dust-proof (complies with DIN40050-IP54)
144(W) × 144(H) × 220(D) mm (D: depth from the panel mounting plane)
1-pen: approx. 2.1 kg, 2-pen: approx. 2.2 kg, 3-pen: approx. 2.3 kg, 4-pen: approx. 2.4 kg
6-dot: approx. 2.5 kg
Normal Operating Conditions
Item Specifications
Ambient temperature
Ambient humidity
0 to 50°C
20 to 80%RH (at 5 to 40°C)
Allowable power supply voltage range
90 to 132, 180 to 264 VAC
Power supply frequency 50 Hz±2%, 60 Hz±2%
Vibration 10 to 60 Hz 0.2 m/s
2
or less
Shock
Magnetic field
Noise
Mounting position
Warm-up time
Altitude
Not acceptable.
400 A/m or less (DC and 50/60 Hz)
Normal mode (50/60 Hz)
Volt: The peak value including the signal must be less than 1.2 times the rated value of the range
(Example: 2 V for 2 V range).
TC: The peak value including the signal must be less than 1.2 times the rated value of the range.
RTD: 50 mV or less
Common mode noise (50/60 Hz): 250 VACrms or less for all ranges
Maximum noise voltage between channels (50/60 Hz): 250 VACrms or less.
Up to 30° of backward tilt angle allowed, no tilt to the left or right
At least 30 minutes after power on
2000 m or less above sea level
Power Supply
Item Specifications
Rated supply voltage 100 to 240 VAC
Allowable power supply voltage range
90 to 132, 180 to 264 VAC
Rated power supply frequency
Rated power
Power consumption
50 Hz, 60 Hz
40 VA
Model 100 VAC
1- to 4-pen model Approx. 12 VA*
6-dot model
* When balanced
Approx. 13 VA*
240 VAC
Approx. 17 VA*
Approx. 18 VA*
Maximum
Approx. 40 VA
Approx. 40 VA
7
7-13
IM 04P03B01-01E
7.6 General Specifications
Isolation
Item
Insulation resistance
Dielectric strength
Grounding
Specifications
Each terminal to ground terminal: 20 MΩ or more (at 500 VDC)
Power supply to ground terminal: 1500 VAC (50/60 Hz), 1 minute
Contact output terminal to ground terminal: 1500 VAC (50/60 Hz), 1 minute
Measuring input terminal to ground terminal: 1000 VAC (50/60 Hz), 1 minute
Between measuring input terminals: 1000 VAC (50/60 Hz), 1 minute (except for RTD input terminal)
Remote input terminal to ground terminal: 500 VDC, 1 minute
Grounding resistance: 100 Ω or less
Transport and Storage Conditions
Item
Ambient temperature
Ambient humidity
Vibration
Shock
Specifications
–25 to 60°C
5 to 95%RH (no condensation)
10 to 60 Hz, 4.9 m/s
2
maximum
392 m/s
2
maximum (in packaged condition)
Supported Standards
Item
CSA
Specifications
Certified by CSA22.2 No. 61010-1, Installation category II
1
, Measurement category II degree 2
3
2
, Pollution
Certified by UL61010B-1 (CSA NRTL/C) UL
CE
EMC
Low voltage directive
C-Tick
Noise
EN61326(Emission: Class A, Immunity: Annex A)
EN61000-3-2
EN61000-3-3
EN55011 Class A Group 1
EN61010-1, Installation category II, Measurement category II, Pollution degree 2
AS/NZS CISPR 11 Class A Group 1
Machine Noise Information Ordinance 3.GSGV, Jan 18, 1991
Maximum noise level: 60 dB (A) or less (complies with ISO7779)
1 Installation category (overvoltage category) describes a number which defines a transient overvoltage condition. It implies the regulation for impulse withstand voltage. “II” applies to electrical equipment which is supplied from the fixed installation like a distribution board.
2 Applies to measuring circuits connected to low voltage installation, and electrical instruments supplied with power from fixed equipment such as electric switchboards.
3 “Pollution degree” describes the degree to which a solid, liquid, or gas which deteriorates dielectric strength or surface resistivity is adhering. “2” applies to normal indoor atmosphere. Normally, only non-conductive pollution occurs.
7-14
IM 04P03B01-01E
7.6 General Specifications
Standard Performance
Item
Measurement and recording accuracy
The following specifications apply to operation of the recorder under standard operation conditions:
Temperature:
Humidity:
23 ± 2°C
55% ± 10%RH
Power supply voltage: 90 to 132 or 180 to 264 VAC
Power supply frequency: 50/60 Hz ± 1%
Warm-up time: At least 30 minutes.
Other ambient conditions such as vibration should not adversely affect the operation
Measurement (Digital Display) Recording (Trend)
Input Type Range Type
DC voltage
20 mV
60 mV
200 mV
2 V
Measurement Accuracy
±(0.1% of rdg + 2 digits)
Highest Res.
Recording Accuracy
10 µV
10 µV
100 µV
1 mV
Measurement accuracy
± (0.3% of recording span)
Resolution
Pen model:
Dead band 0.2% of recording span
Dot model:
Resolution 0.1 mm
DC voltage
TC
(excludes
RJC accuracy)
6 V
20 V
50 V
1-5 V
R
S
B
±(0.1% of rdg + 3 digits)
±(0.1% of rdg + 2 digits)
±(0.15% of rdg + 1°C) except R,S: 0 to 100°C, ±3.7°C
100 to 300°C, ±1.5°C
B: 400 to 600°C, ±2°C
Accuracy not warranted for values less than 400°C
1 mV
10 mV
10 mV
1 mV
0.1°C
K
±(0.15% of rdg + 0.7°C) except ±(0.15% of rdg + 1°C) for –200 to –100°C
E
J
T
±(0.15% of rdg + 0.5°C) except ±(0.15% of rdg + 0.7°C) for: –200 to –100°C
N
W
L
U
Specifications
±(0.15% of rdg + 0.7°C)
±(0.15% of rdg + 1°C)
±(0.15% of rdg + 0.5°C) except ±(0.15% of rdg + 0.7°C) for: –200 to –100°C
WRe
RTD
ON/OFF input
Pt100
JPt100
Level
Contact
±(0.2% of rdg + 1°C)
±(0.15% of rdg + 0.3°C)
Threshold level (2.4 V) accuracy ± 0.1 V
≤ 1 KΩ: ON, ≥ 100 kΩ: OFF
(Parallel capacitance
0.01 µF or less)
–
–
Measuring accuracy in case of linear scaling
Accuracy during scaling (digits) = measuring accuracy (digits) × multiplier + 2 digits (rounded up) where the multiplier = scaling span (digits)/measuring span (digits).
Example: Assuming that
• range type: 1-5 V
• measuring span: 1.000 to 5.000 V
• scaling span: 0.000 to 2.000 Then,
Measuring accuracy = ±(0.1% × 5 V + 2 digits)
= ±(0.005 V [5 digits] + 2 digits)
= ±7 digits
Multiplier = {2000 digits (0.000 to 2.000)}/{4000 digits (1.000 to 5.000)} = 0.5
Accuracy during scaling = ±(7 × 0.5 + 2) digits = 6 digits (rounded up)
Reference junction compensation
Internal/External selectable for each channel
IM 04P03B01-01E
7-15
7
7.6 General Specifications
Item Specifications
Reference junction compensation accuracy
Maximum input voltage
Above 0°C with input terminal temperature balanced (60 minutes after power on)
Type R, S, B, W, WRe: ±1.0°C
Type K, J, E, T, N, L, U: ±0.5°C
±10 VDC (continuous) for ranges of 200 mV or less, TC, RTD, and DI ranges
Input resistance
Input source resistance
±60 VDC (continuous) for 2 VDC or higher ranges
Approximately 10 MΩ or more for ranges of 200 mV or less and TC
Approximately 1 MΩ for 2 VDC or higher ranges
Volt, TC: 2 kΩ or less
RTD input: 10 Ω or less per wire (The resistance of all three wires must be equal).
10 nA or less (except when burnout detection function is enabled) Bias current
Common mode rejection ratio 120 dB (50/60 Hz ± 0.1%, 500 Ω unbalanced, between the minus terminal and ground)
Normal mode rejection ratio 40 dB or more (50/60 Hz ± 0.1%)
Noise rejection By the integrating A/D converter: The integration time is 16.7 ms, 20 ms, or 100 ms (dot model)
Low-pass filtering (pen model): Filter time constant is 2 s, 5 s, or 10 s
Moving average (dot model): The number of samples is 2 to 16.
Effects of Operating Conditions
Item Specifications
Ambient temperature With temperature variation of 10°C:
Measurement: ±(0.1% of rdg + 1 digit) or less
Recording: Measurement fluctuation + ±0.2% of the recording span or less
* Excluding the error of reference junction compensation
Power supply fluctuation With variation within 90 to 132 V and 180 to 264 VAC (50/60 Hz):
Magnetic field
Measurement: ±1 digit or less
Recording:
±0.1% of the recording span or less
With variation of ±2 Hz from rated power frequency (power supply voltage 90 to 132, 180 to 264 VAC):
Measurement: ±(0.1% of rdg + 1 digit) or less
Recording: Same as the measurement fluctuation
AC (50/60 Hz) and DC 400 A/m fields:
Measurement: ±(0.1% of rdg 10 digits) or less
Recording:
±0.5% of the recording span or less
Input source resistance
DC voltage range
TC range
RTD range
Mounting position
Vibration
With variation of +1 kΩ:
Ranges of 200 mV or less: Within ±10 µV
Ranges of 2V or more:
±0.1% of rdg
With variation of +1 kΩ: ±10 µV or less
With variation of 10 Ω per wire (resistance of all three wires must be equal):
Measurement: ±(0.1% of rdg + 1 digit) or less
Recording: Measurement fluctuation + ±0.1% of the recording span or less
With maximum difference of 40 mΩ between wires: Approx. 0.1°C (for Pt100)
With a backward tilt of 30° or less
Measurement: ±(0.1% of rdg + 1 digit) or less
Recording: Indication fluctuation + ±0.1% of the recording span or less
When a sinusoidal vibration along all three axis at a frequency between 10 to 60 Hz and an acceleration of 0.2 m/s
2
is applied for 2 hours
Measurement: ±(0.1% of rdg + 1 digit) or less
Recording: Indication fluctuation + ±0.1% of the recording span or less
Other Specifications
Item
Clock
Accuracy of clock
DST
Memory backup
Key Lock Function
Key Lock Items
Specifications
With a calendar function
±100 ppm, excluding a delay (of 1 second, maximum) caused each time the power is turned on.
The date/time for switching between standard time and DST can be specified.
A built-in lithium battery backs up the setup parameters and runs the clock
(battery life: approximately ten years at room temperature).
Password for releasing the key lock can be set.
RCD key, MENU key, FEED key, and function under the FUNC key (manual printout, list printout, setup list printout, message printout, printout buffer clear, and pen/ribbon cassette exchange)
7-16
IM 04P03B01-01E
Index
Symbols
1-5V .................................................................................... 1-1
1-5V input, low-cut function for ......................................... 4-20
A
A/D converter, integration time of ....................................... 4-3
accuracy of clock .............................................................. 7-16
alarm ........................................................................... 2-9, 7-3
alarm conditions .................................................................. 1-6
alarm hysteresis .......................................................... 1-6, 4-2
alarm information printout ................................................... 4-9
alarm output relay ............................................................... 4-2
alarm output relays ............................................................. 1-7
alarm printout .................................................................... 1-13
B
bias ................................................................. 1-3, 3-10, 4-20
burnout detection ................................................................ 1-4
burnout detection function ................................................... 4-4
C
calibration ............................................................................ 6-3
calibration correction ..................................... 3-11, 4-20, 4-25
calibration instrument .......................................................... 6-3
channel number printout ..................................................... 4-9
channel printout ................................................................ 1-11
characters that can be used for units ................................ 2-11
chart paper .......................................................................... 7-4
chart speed ............................................................... 1-8, 2-12
cleaning ............................................................................... 6-2
compensation voltage ......................................................... 4-5
construction ....................................................................... 7-13
conventions used in this manual ........................................... iii
current input ........................................................................ 1-1
customized menu .................................................... 1-17, 4-30
customized menu, selection of ................................ 4-26, 4-28
D
date format ........................................................................ 4-18
date/time ........................................................................... 2-13
de-energized ....................................................................... 1-7
decimal place ...................................................................... 2-4
delta computation ................................................................ 1-2
diagnosis output .................................................................. 1-7
diagnosis output relay ......................................................... 4-2
displayed contents .............................................................. 7-7
dot printing interval ...................................................... 1-8, 3-1
dot printing position adjustment .......................................... 6-7
downscale ........................................................................... 4-4
DST ................................................................................... 3-13
IM 04P03B01-01E
E
edge .................................................................................. 1-16
effects of operating conditions .......................................... 7-16
energize/de-energize operation .......................................... 4-2
energized ............................................................................ 1-7
error messages ................................................................... 5-1
external reference compensation ........................................ 1-3
external RJC function .......................................................... 4-5
F
filter ........................................................................... 1-4, 4-15
filter time constant ............................................................... 3-2
font .................................................................................... 4-17
functions to be assigned (remote control) ......................... 4-24
H
hysteresis adjustment ......................................................... 6-8
I
initialization ....................................................................... 4-23
input range .......................................................................... 2-1
input type ............................................................................ 7-1
integration time ................................................................... 4-3
integration time of the A/D converter .................................. 1-5
internal clock adjustment .................................................. 1-16
isolation ............................................................................. 7-14
K
key lock ............................................................................. 1-17
key lock, key operation of ................................................. 4-13
L
LED ..................................................................................... 7-7
level ................................................................................... 1-16
low limit alarm ..................................................................... 1-6
low-cut ............................................................... 2-3, 2-7, 4-20
low-cut point ........................................................................ 2-7
M
manual printout ................................................................. 1-13
measurable range ............................................................... 1-1
memory backup ................................................................ 7-16
message printout .............................................................. 1-13
messages, characters that can be used for ........................ 3-8
moving average ........................................................ 1-4, 4-14
moving average, number of samples of .............................. 3-3
N
new chart speed printout ........................................... 1-13, 4-8
normal operating conditions .............................................. 7-13
number of correction points .............................................. 4-25
Index-1
Index
Index
O
Offset compensation mark ................................................ 1-12
optional functions ................................................................ 7-9
P
partial expanded recording ......................................... 1-9, 3-5
partial expanded recording function .................................. 4-16
password ................................................................. 4-13, 4-30
pen offset compensation ............................................. 1-9, 4-7
pen position adjustment ...................................................... 6-5
periodic inspection .............................................................. 6-1
power supply ..................................................................... 7-13
printout contents ............................................................... 1-10
printouts .............................................................................. 7-5
R
range type ........................................................................... 1-1
recording span .................................................................... 1-1
recording start printout .............................................. 1-13, 4-8
recording zone .................................................................... 3-4
reference junction compensation ........................................ 1-3
reference pen ...................................................................... 1-9
relay No. ............................................................................ 2-10
remaining chart length ........................................................ 6-1
remote control ......................................................... 1-16, 4-24
remote signal .................................................................... 1-16
revisions .................................................................................. i
RJC ..................................................................................... 4-5
S
scaling ......................................................................... 1-2, 1-3
scan interval ........................................................................ 1-1
secondary chart speed ........................................................ 3-9
selectable span range ......................................................... 2-2
selectable span range (delta computation) ......................... 2-5
shunt resistor ...................................................................... 1-1
skip ...................................................................................... 2-8
square root computation ..................................................... 1-2
square root computation, low-cut function for ................... 4-20
standard performance ....................................................... 7-15
standard temperature device .............................................. 6-4
supported standards ......................................................... 7-14
T
tag printout .......................................................................... 4-9
tags, characters that can be used for .................................. 3-7
temperature unit, changing of ........................................... 4-33
time printout format ................................................. 1-13, 4-21
trend recording .................................................... 1-8, 3-6, 7-4
trend recording color ........................................................... 4-6
trend recording interval ....................................................... 3-1
trigger ................................................................................ 1-16
troubleshooting ................................................................... 5-4
types of inputs ..................................................................... 1-1
U
upscale ................................................................................ 4-4
Y
year ................................................................................... 2-13
Z
zone recording .................................................................... 1-8
Index-2
IM 04P03B01-01E
Advertisement