Below you will find brief information for Vehicle Weighing Scale RW-2201B, Weighing Pad RW-15B. This manual covers the setup, configuration, and operation of the RW-2201B Vehicle Weighing Scale and RW-15B Weighing Pads. It describes how to connect the scale to the pads, configure the display, measure the weight of vehicles, and print the results. The manual also covers troubleshooting tips and error codes.
Advertisement
Advertisement
2
Table of Contents
1. Introduction.......................................... 5
2. Feature & Main function ..................... 6
5. Test mode ........................................... 11
7. How to measure vehicle...................17
8. Method of using(RW-15B)................18
9. How to save data ...............................20
10. Change roll of print .........................22
11.
3
1. Introduction
Thank you for purchasing the CAS RW-2201B Series weighing indicator. We have designed this equipment with many advanced features, high quality construction, and user-friendly menu driven programming. We are confident that you will find the CAS RW-2201B Series will meet all of your most demanding needs. CAS indicator is shaped firmly and delicately designed to coincide with the special requirements of several industrial fields and includes many functions and various external interfaces. Also, it contains help display functions to be used easily.
Before using RW-2201B, It is recommended to read this manual carefully and to apply the function application fully.
Precautions
Observe the following safety precautions :
Warning
When any damage or defect occurs, contact your CAS authorized dealer immediately for proper repair.
Insert plug firmly to wall outlet to prevent electric shock.
Avoid placing the scale near heather or in direct sunlight.
Do not pull the plug by its cord when unplugging. Damaged cord could cause electric shock or fire.
To prevent from fire occurring,
Do not place or use the scale near flammable or corrosive gas.
To reduce electric shock or incorrect reading, Do not spill water on the scale or place it in humid condition.
4
Attention
For consistent and accurate reading, maintain periodical check by your CAS authorized dealer.
Avoid sudden shock to the scale.
Internal mechanism could by damaged.
Attach the rubber pad to the bottom of the indicator.
Elimination is possible.
Place the scale on firm and temperature consistent environment.
Keep the scale away from the electromagnetic generation devices.
This may interfere with accurate reading.
Our Dealers : CAS feels that each of its valued customers should get the best service available. Whether it’s the initial installation of our product, maintenance/repair work, or simply answering questions about our products, CAS Corporation and all of its Authorized Dealers are highly trained to assist you with any need regarding CAS products.
5
2. Feature & Mainfunction
Feature
Simple & Light & Portable.
Easy Control
Internal battery.
Internal battery charger
With Backlight
Internal Printer
3. Technical Specification
RW-2201B
Display
Character size
Display under zero
Display status
Power
Operation temperature
Wireless communication
Composition
Product weight
Using time
Charging time
Digital & Display
LCD (6 digit + Sign)
24 mm (height)
"-" minus display
ZERO, STABLE, UNIT(kg)
AC 220 V 50/60Hz
-10℃ ~ 40℃℃
Blue tooth
RW-2201B , RW-15B(2sets)
About 10.6kg
About 48 hours
About 24 hours
6
RW-15B
A/D Speed
External resolution
Using time
Using key
Battery
Inner Power / Power consumption
Weight
Digital & Display
10 times/second
1/750( Max capa : 15t, 1d : 20kg )
about 10hours(Continue comm.)
Power ON/OFF
4.8V(1.2V * 4EA), 1.3A (NI-MH)
Inner Power : 3.3V /
Power consumption : about 0.5 W
About 27kg(except Ramp, Ramp Weight : 10kg)
Wireless communication
Frequency
CHANNEL
Communication speed
Communication distance
Communication
BLUETOOTH method (CLASS 1)
2.402 ~ 2.483GHz
78 CHANNELS(HOPPING method)
9600bps
Opensite : about 50M
At barrier place : about 30M
Notice. Communication distance will be changed by circumstance.
7
4. Front pannel
■ Display Lamp
Display Brief
Stable lamp
Zero lamp
Sum lamp
Percent lamp
RX 1
RX 2
PAD1
Low battery lamp
LO Low battery lamp
Red lamp on printer
Green lamp on printer
Power lamp of printer
Self-Test lamp of printer
8
Description
A Display this lamp at stable
Display this lamp at zero
Display this lamp at sum mode
Display capacity of battery (%)
Display the status of PAD1 comm.
Display the status of PAD2 comm.
Display the weight of PAD1
Low battery lamp of RW-2201B
Low battery lamp of RW-15B
Display the power-on of printer
Display the ok or not ok of printer
■ Key Board
Short
ZERO
Used to remove small vibration
Short
Long
PAD
Check the weight of each PAD
Power off the all PAD (Display “OFF”)
Short
Used to print and sum weight
Long Used to lock print (To print, input the pre-setting password in F02)
Notice. Check first the setting mode before use this function. (F03->1).
SUM
Short Print all PAD weight of one vehicle
Notice. It can not print weight of all vehicle one day.
FIND
Short Find saved data
Notice. Yon can print data of saved data
TRUCK No.
Short To input vehicle number(4 digit)
9
SAVE
Short
To save the weight of PAD
( Max 10 vehicle/ Max 4 PAD weight of one vehicle)
Short
Long
Long To move next mode.
Notice. If you press this key very often, it will be saved data every time at other memory.
SET
Short
Long
To go next mode or to save data
To enter SET mode
CLR
To erase data
To enter TEST mode
10
5. TEST MODE
□
How to enter TEST mode
Turn on Power while press ‘CLR’ key to enter test mode..
You will see massage (conect ). Press ‘SET’ key and then move to test menu.
□
TEST menu(TEST1 ~ TEST6)
TEST 1 : Key test
TEST 2 : Battery test of RW-2201B
TEST 3 : Load-cell test of PAD1
TEST 4 : Load-cell test of PAD2
TEST 5 : Clock test
TEST 6 : Print test
TEST 1
Key Function
SET
Move to TEST2
Key test
Display
tESt 1
Description
This is status of TEST 1
Other key
Operate test 1 Press key, display value of key code.
key
1 2 3 4 5 6 7 8 9 0
code
1 2 3 4 5 6 7 8 9 0
TEST 2
CLR
A
Battery TEST of RW-2201B
Key Function
SET Move to TEST3
Display Description
tESt 2 This is status of TEST 2
6.00 Battery value of RW-2201B
SET b
11
TEST 3
Load Cell TEST of PAD1
Key Function
SET Move to TEST4
TEST 4
Load Cell TEST of PAD2
Key Function
SET Move to TEST5
TEST 5
Clock test
Key Function
SET
Move to time setting or TEST6
TEST 6
Printer test
Key
SET
Function
Move to weighing mode
Notice. Output of print is below.
Display Description
tESt 3 This is status of TEST 3
24750 AD value of PAD1
Display
tESt 4
23564
Display
tESt 5
06.11.09
12.02.32
Display
tESt 6
600d
Description
This is status of TEST 4
AD value of PAD2
Description
This is status of TEST 5 dAtE : Display date. tIME : Display time
Description
This is status of TEST 6
Operate printer test
TEST OK
12
6. SET MODE
□
How to enter SET mode
Turn on Power while press ‘SET’ key or press long ‘SET’ key in weighing mode.
□
SET Mode menu
Menu Description
F03
F04
F05
F06
Setting lock of print key
Setting communication error message display
Setting auto-save data at printing
Setting number of using PAD
Key Function
F01 (Setting backlight)
Display Value
Other Key 0 ~ 3 key
SET
Save and exit the set mode
F01
Description
1 At pressing key
13
Key
SET
Function
Select 0 or 1
Save and exit the set mode
F02 (Change password)
Display
F02
Value
0
Description
To do not change pass word
1 To change password
F02 = 1(To change password)
Key
SET
Enter the pas sword
PASS
Display
_ _ _ 0
Input 4 number of password
Good
SET
PASS 1
_ _ _ 0
Input new password
PASS 2
SET Retry input new password
_ _ _ 0
Notice. Initial password is ‘1234’ in factory
If PASS 1 is different from PASS 2, RW-2201B display error message ‘Err 31’, come back input mode of PASS1 .
Key Function
Key Select 0 ~ 1
SET Exit set mode
F03 (Setting lock of print key)
Display Value
1
Description
Use of lock
F03
You must check F02 before this mode.
Key Function
Key Select 0 ~ 1
SET Exit set mode
F04 (Display comm. Error message)
Display
F04
Value
1
0
Description
Don’t use.
Display comm Error .
14
Key Function
Key Select 0 ~ 1
SET
Exit the set mode
F05 (Auto save setting)
Display Value
1
Description
Auto save at print
F05
Key Function
Key Select 0 ~ 2
S E T
S E T
Exit the set mode
F06 (Setting number of pad)
Display
F06
Notice. PAD number is written on spec-plate.
Value
0
Description
Use 2 PAD
1
2
Use 1 PAD(Number 1)
Use 1 PAD(Number 2)
F11 (Auto print)
Key Function Display Value Description
Key Select 0 ~ 1
SET
Move the
next mode
F11
0
1
Don’t use this function
Only status of stable
Notice. If you select 1 of F11, this function is operated when the weight is over 1% max capacity.
15
Key
Key
SET
Function
Select 0,1,5
Move the next mode
F12 (Line feed)
Display
F12
Value Description
0 0 line feed.
∫ ∫
5 5 line feed.
Format
2006.11.24 14:32:54
Truck No.:1234
------------- AXLE 1 -----------
WEIGHT1: 12056 kg
WEIGHT2: 10150 kg
-------------------------------
AXLE1 TOTAL : 22206 kg
Total Format
---- TOTAL PRINT ----
Truck No. : 1234
TOTAL AXLE. : 2
TOTAL : 4234kg
` ------------ AXLE 2 -----------
WEIGHT1: 2056 kg
WEIGHT2: 4150 kg
-------------------------------
AXLE2 TOTAL : 6206 kg
F13 (Setting time)
Key Function Display Value Description
Key
SET
Select 0or1
End of set mode
F13
06.09.18
10.30.54
Notice. If date-input is done, it will be change mode of input- time.
Input date
Input time
16
7. How to measure vehicle
See the below picture. As you shown, you can weigh the vehicle four time
1) If vehicle is on the PAD, press print key because save the data and print data.
2) If weighing is done, you can ready next weighing. Also if vehicle is on the PAD, press print key. The reason is same.
3) Repeat 2 times.
4) Gross weight of vehicle : If weighing is all done, press sum key because RW-2201B print gross data (with 4 axel weight data)
Sort 1 step 2 step 3 step 4 step
2
A
X
E
L
1) without dummy
(2 PLATE)
2) use dummy
(2 PLATE + 2
DUMMY PLATE )
4
A
X
E
L
3
A
X
E
L
1) use dummy
(2PLATE +
12 DUMMY)
1)use dummy
(2PLATE +
12 DUMMY)
Notice : Even measuring by Dummy plate, error of the actual weight can happen.
(The error range is +/-3% from the Maximum capacity)
17
8. Method of using(RW-15B)
Using
POWER ON/OFF
1. POWER ON : Press power S/W for 2 sec.
2. POWER OFF : Press power S/W
POWER LAMP
1. LAMP OFF : This is status of power off.
2. LAMP ON : This is status of power on.
3. LAMP blinking : RW-15B is needed for charging. notice. As you shown side picture, raised antenna help communication n far more than lay.
18
9. How to save data
Method 1.
1. If wheel of vehicle on pad, press save key.
- “1 SAVE” is display. This means wheel weight save done .
2. Repeat the procedure 4times (1 vehicle)
3. If you done, press save key long. Then It will show END message
- This procedure is for save data. The result is saved weight of one vehicle.
- If you see the “FULL” message, memory is full.
- It has memory of 10 vehicle.
Method 2
If you set 1 of F05, auto save function is used.
Auto save function is saved at print. It is done at Total print.
Notice . It is saved 4 axel weight data per vehicle.
If exceed 4 axel weight data, will overwrite old data.
Search the saved data
1. Press FIND key.“Then it will be show 0-XXXX.
- First number means order of saving and second number means number of vehicle.
2. Press 2 key or 8 key. It will be show save vehicle number.
3. If you find what you want vehicle number, press print key.
4. If you delete data, press CLR. All saved data is erased.
19
10. Change printer roll.
As you show above picture, press line feed key after insert roll.
Then the paper is passing through cartridge. Press line feed key again. Then the paper is stop.
This is done.
See above the picture. It is picture of removed cartridge.
If letter is not clear, you must change cartridge.
Method of change is very simple. Hold on the cartridge and pull up.
20
11. Error message & Trouble shooting
No
t1-out t2-out
Err2-1
Err2-2
Reason
Fail to communication t1-out : PAD1, t2-out : PAD 2
A/D value is wrong
Err2-1 : PAD 1, Err2-2 : PAD 2
Trouble shooting
Too far or many barrier.
Get close or remove barrier.
Check the pad power.
Then operate TEST3, TEST 4.
Check A/D value
Err 11
Err 12
Over the initial zero range.
Err 11 : PAD 1 , Err12 : PAD 2
Clear on the pad.
Initial zero range is within 20% of Max weight.
Err 30 numbers.
Err 31
Entered password is different from old password.
Enter new password again.
Err 50 Internal memory is erased Call your CAS dealer
BT-Err Fail to communication
OUER 1 Over the max weight of PAD1
OUER 2 Over the max weight of PAD2 batt Low battery of RW-2201B
Retry communication.
This may damage load-cell.
You must reduce the weight under the max capacity.
This may damage load-cell.
You must reduce the weight under the max capacity.
You must recharge the RW-2201B.
21
MEMO
22
MEMO
23
24

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Easy to use menu driven programming
- Internal battery for portable use
- Internal battery charger
- Backlit display
- Internal printer
- Bluetooth wireless communication
- Capacity of 15t (20kg divisions)
- Accurate weighings, with error range +/-3% of maximum capacity