Planet ICA-8350 Quick Installation Guide

Add to my manuals
16 Pages

advertisement

Planet ICA-8350 Quick Installation Guide | Manualzz

3 Mega-Pixel Vari-Focal IR / Fisheye IP Camera

ICA-3350V / ICA-5350V / ICA-8350

Quick Installation Guide

Table of Contents

Chapter 1. Introduction .................................................................................... 3

1.1 Before Installation ............................................................................... 3

1.2 System Requirements .......................................................................... 3

Chapter 2. Physical Description and Installation .................................................. 4

2.1 ICA-3350V 3 Mega-Pixel Vari-Focal Bullet IR IP Camera .......................... 4

2.1.1 Package Content ........................................................................ 4

2.1.2 Physical Details .......................................................................... 4

2.1.3 Installation ................................................................................ 6

2.2 ICA-5350V 3 Mega-Pixel Vandal Proof IR IP Camera ............................... 7

2.2.1 Package Content ........................................................................ 7

2.2.2 Physical Details .......................................................................... 7

2.2.3 Installation ................................................................................ 9

2.3 ICA-8350 3 Mega-Pixel Vandal Proof Fisheye IP Camera ........................10

2.3.1 Package Content .......................................................................10

2.3.2 Physical Details .........................................................................10

2.3.3 Installation ...............................................................................12

Chapter 3. Camera Windows Utility ..................................................................13

Further Information ........................................................................................16

Chapter 1. Introduction

Thank you for purchasing the PLANET 3 Mega-Pixel Vari-Focal IR / Fisheye IP

Camera. It is versatile and high image solution of surveillance application for day and night. The PLANET IP Camera support Multi-Profile function can stands for simultaneously video streams. These Network Cameras can generate H.264,

MPEG-4 and M-JPEG streaming simultaneously to different clients. Moreover, the resolution can be different from one client to another. This state-of-art design is considerable to fit in various network environments.

1.1 Before Installation

Before installation, please be sure to read this quick installation guide and user’s manual (CD) carefully to complete machine installation. This guide shows how to quick set up these cameras, unless model name specified terms “IP Camera” will be used for these three models.

1.2 System Requirements

CPU

RAM

Video RAM

Display Resolution

Operating System

DirectX

Network

Intel Dual Core 2.4GHz or higher

2GB (above Recommended)

256MB (above Recommended)

1280x1024 24bits or above

Windows XP / Vista / Win7

10 or above

Wired Ethernet 100Base-TX

3

Chapter 2. Physical Description and Installation

2.1 ICA-3350V 3 Mega-Pixel Vari-Focal Bullet IR IP Camera

2.1.1 Package Content

ICA-3350V x 1

Power Adapter x 1

Accessory Kit x 1

User’s Manual CD x 1

Quick Installation Guide x 1

If any of the above items are missing, please contact your dealer immediately.

Note

2.1.2 Physical Details

ICA-3350V Connector

DI/DO

12V

DI

GND

DO

485+

485-

3

4

1

2

5

6

VIDEO

Color Pink

Color Green

MIC

AUDIO

+

DC

Orange

LED

8

RJ-45

1

Green

LED

RESET

4

Interface

RJ45 LAN socket

DC-in Jack

Description

Connects to your local area network by Ethernet cable.

LAN LED (green color)

This LED will be flashing while network accessing via Ethernet.

Power LED (orange color)

This LED is used to indicate whether DC power is on or not.

DC power input, connect to AC power adapter.

Note

To ensure maximum compatibility, use only the power adapter that came with your product. Otherwise, the product may be damaged.

RS-485 &

Digital I/O

RS-485: Connect to a local keyboard controller.

DI/ DO: Connect to sensor in and alarm out devices.

Cable for I/O connectors:

Name

12VDC

DI

GND

DO

485+

485-

Number

1

2

3

4

5

6

DC 12V (50mA maximum)

Digital signal input

GND

Function

Digital signal output

RS485 data +

RS485 data -

MIC in

(Audio in)

Audio out

Video out

(BNC connector)

Connect a microphone to the network camera.

Connect a loud speaker to the network camera. This function is for voice alerting and two-way audio.

The Network Camera also provides composite video output.

The video output function is only for easy installation to check view angle and focus. The output is not a Mega-Pixel resolution.

Furthermore, only “720P Mode” supports this function. “2 Mega

Mode” does not support it. Please refer to Setting \ Video \

Common chapter.

5

Reset

This button is used to restore the all factory default settings.

Sometimes restarting the device will make the system back to a normal state. However, if the system still got problems after restart, user can restore the factory default settings and install it again.

Restore the device:

1. While the Camera is ready and then press the button down continuously.

2. Hold the button at least 5 seconds and release it. Then the device has been restored to default settings and reboot again.

Note

Restoring the factory default setting will lose the all previous settings included IP address forever. User needs to run the IPWizard II program to search the device and configure it to let the device work properly again.

2.1.3 Installation

1. Fix IR camera to desired location with wall mount fixture.

2. Plug-in Ethernet Cable into RJ-45 connector.

Connect an Ethernet cable to the LAN socket located on the Network Camera’s back panel and attach it to the network.

3. Connect RS485 D+ and D- (if you need to control PT scanner).

4. Connect the attached power adapters to camera and heater (option/by model) and plug-in these adapters into power outlet.

5. Done.

6

2.2 ICA-5350V 3 Mega-Pixel Vandal Proof IR IP Camera

2.2.1 Package Content

ICA-5350V x 1

Power Adapter x 1

Accessory Kit x 1

User’s Manual CD x 1

Quick Installation Guide x 1

If any of the above items are missing, please contact your dealer immediately.

Note

2.2.2 Physical Details

ICA-5350V Connector

DI/DO

12V

DI

GND

DO

485+

485-

3

4

1

2

5

6

VIDEO

MIC

AUDIO

+

DC

Orange

LED

8

RJ-45

1

Green

LED

RESET

Color Pink

Color Green

7

8

Interface

RJ45 LAN socket

DC-in Jack

Description

Connects to your local area network by Ethernet cable.

LAN LED (green color)

This LED will be flashing while network accessing via Ethernet.

Power LED (orange color)

This LED is used to indicate whether DC power is on or not.

DC power input, connect to AC power adapter.

Note

To ensure maximum compatibility, use only the power adapter that came with your product. Otherwise, the product may be damaged.

RS-485 &

Digital I/O

RS-485: Connect to a local keyboard controller.

DI/ DO: Connect to sensor in and alarm out devices.

Cable for I/O connectors:

Name Number Function

12VDC

DI

GND

DO

485+

485-

1

2

3

4

5

6

DC 12V (50mA maximum)

Digital signal input

GND

Digital signal output

RS485 data +

RS485 data -

MIC in

(Audio in)

Audio out

Video out

(BNC connector)

Connect a microphone to the network camera.

Connect a loud speaker to the network camera. This function is for voice alerting and two-way audio.

The Network Camera also provides composite video output.

The video output function is only for easy installation to check view angle and focus. The output is not a Mega-Pixel resolution.

Furthermore, only “720P Mode” supports this function. “2 Mega

Mode” does not support it. Please refer to Setting \ Video \

Common chapter.

Reset

This button is used to restore the all factory default settings.

Sometimes restarting the device will make the system back to a normal state. However, if the system still got problems after restart, user can restore the factory default settings and install it again.

Restore the device:

1. While the Camera is ready and then press the button down continuously.

2. Hold the button at least 5 seconds and release it. Then the device has been restored to default settings and reboot again.

Note

Restoring the factory default setting will lose the all previous settings included IP address forever. User needs to run the IPWizard II program to search the device and configure it to let the device work properly again.

2.2.3 Installation

1. Fix IR camera to desired location with wall mount fixture.

2. Plug-in Ethernet Cable into RJ-45 connector.

Connect an Ethernet cable to the LAN socket located on the Network Camera’s back panel and attach it to the network.

3. Connect RS485 D+ and D- (if you need to control PT scanner).

4. Connect the attached power adapters to camera and heater (option/by model) and plug-in these adapters into power outlet.

5. Done.

9

2.3 ICA-8350 3 Mega-Pixel Vandal Proof Fisheye IP Camera

2.3.1 Package Content

ICA-8350 x 1

Power Adapter x 1

Accessory Kit x 1

User’s Manual CD x 1

Quick Installation Guide x 1

If any of the above items are missing, please contact your dealer immediately.

Note

2.3.2 Physical Details

ICA-8350 Connector

DI/DO

12V

DI

GND

DO

485+

485-

3

4

1

2

5

6

VIDEO

MIC

AUDIO

+

DC

Orange

LED

8

RJ-45

1

Green

LED

RESET

Color Pink

Color Green

10

Interface

RJ45 LAN socket

DC-in Jack

Description

Connects to your local area network by Ethernet cable.

LAN LED (green color)

This LED will be flashing while network accessing via Ethernet.

Power LED (orange color)

This LED is used to indicate whether DC power is on or not.

DC power input, connect to AC power adapter.

Note

To ensure maximum compatibility, use only the power adapter that came with your product. Otherwise, the product may be damaged

RS-485 &

Digital I/O

RS-485: Connect to a local keyboard controller.

DI/ DO: Connect to sensor in and alarm out devices.

Cable for I/O connectors:

Name

12VDC

DI

GND

DO

485+

485-

Number

1

2

3

4

5

6

DC 12V (50mA maximum)

Digital signal input

GND

Function

Digital signal output

RS485 data +

RS485 data -

MIC in

(Audio in)

Audio out

Video out

(BNC connector)

Connect a microphone to the network camera.

Connect a loud speaker to the network camera. This function is for voice alerting and two-way audio.

The Network Camera also provides composite video output.

The video output function is only for easy installation to check view angle and focus. The output is not a Mega-Pixel resolution.

Furthermore, only “720P Mode” supports this function. “2 Mega

Mode” does not support it. Please refer to Setting \ Video \

Common chapter.

11

Reset

This button is used to restore the all factory default settings.

Sometimes restarting the device will make the system back to a normal state. However, if the system still got problems after restart, user can restore the factory default settings and install it again.

Restore the device:

1. While the Camera is ready and then press the button down continuously.

2. Hold the button at least 5 seconds and release it. Then the device has been restored to default settings and reboot again.

Note

Restoring the factory default setting will lose the all previous settings included IP address forever. User needs to run the IPWizard II program to search the device and configure it to let the device work properly again.

2.3.3 Installation

1. Fix IR camera to desired location with wall mount fixture.

2. Plug-in Ethernet Cable into RJ-45 connector.

Connect an Ethernet cable to the LAN socket located on the Network Camera’s back panel and attach it to the network.

3. Connect RS485 D+ and D- (if you need to control PT scanner).

4. Connect the attached power adapters to camera and heater (option/by model) and plug-in these adapters into power outlet.

5. Done.

12

Chapter 3. Camera Windows Utility

This chapter shows how to quick set up your 3 Mega-Pixel Vari-Focal IR / Fisheye

IP Camera. The 3 Mega-Pixel Vari-Focal IR / Fisheye IP Camera is with the default settings. However to help you find the networked camera quickly the windows utility (PLANET IPWizard II) can search the IP cameras in the network that shall help you to configure some basic setting before you started advanced management and monitoring.

Please insert the bundle CD disk into your CD/DVD-ROM drive. When the welcome web page appears, please click your IP camera name on the IP camera list. Then click the PLANET IPWizard II hyperlink to start the PLANET IPWizard II.

Search function:

Press “Search” button. PLANET IPWizard II will list all networked devices in the

LAN. If the IP camera doesn’t be found, you may check this IP camera is connect to network properly and press the search button again.

13

View function:

If PLANET IPWizard II finds network devices, View button will be available. Please select the device you want to view and click the View button. Furthermore you could double click the left button of mouse to link to the network device by browser.

LAN setting:

The utility featured with “LAN” setting function to help user to modify the IP parameters of the installed network devices. User can step by step to setup IP address, username and password.

14

Note

1. If no IP address is assigned within 30 seconds, the networked device will automatically assign 192.168.0.20. User may now open your web browser, and key in http://192.168.0.20 in the address bar of you web browser to logon IP Camera’s web configuration page.

2. Power Line Frequency

- If you found the video image is flash, you may need to choose

50 or 60 Hz frequency (depends on different country).

- World wide power line frequency table is inside user’s manual,

Appendix.

After connected to networked device, the device will prompt for User name and

Password. For the first time, please enter: admin/admin as username and password to continue Web Management.

XXXXX

Default User Name: admin

Default Password: admin

Default IP: 192.168.0.20 – if no DHCP existed in the network

If difficulty is met, please refer to the following steps to establish the connection:

- The networked device must be installed and powered ON.

If the networked device’s default IP Address (192.168.0.20) is already used by another device, the other device must be turned OFF until the device is allocated a new IP Address during configuration.

15

Further Information

This guide is used to help you startup your IP Camera settings. It is also recommended to check the user manual in CD disk for more details of the system and user configuration.

16

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals