The SSINVERTER SSI700 is a versatile AC drive designed for controlling asynchronous motors. It offers a wide range of functionalities, making it suitable for various automation applications in industries like textile, paper-making, food processing, and more. This drive features multiple control modes, communication protocols, and advanced features like virtual I/O, rapid current limit, and virtual I/O, providing precise and efficient motor control.
PDF
Download
Document
Advertisement
Advertisement
SSI700 User Manual Preface Thank you for purchasing the SSI700 series AC drive developed by SSINVERTER Co., Ltd. The SSI700 series AC drive is a general-purpose current vector control AC drive. It is an upgrade product based on SSI700 and can implement the control of asynchronous motor It increases the user programmable function, back ground monitoring software and communication bus function . It is used to drive various automation production equipment involving textile, paper-making, wiredrawing, machine tool, packing, food, fan and pump. This manual describes the correct use of the SSI700 series AC drive, including selection, parameter setting, commissioning, maintenance & inspection. Read and understand the manual before use and forward the manual to the end user. Notes • The drawings in the manual are sometimes shown without covers or protective guards. Remember to install the covers or protective guards as specified first, and then perform operations in accordance with the instructions. • The drawings in the manual are shown for description only and may not match the product you purchased. • The instructions are subject to change, without notice, due to product upgrade, specification modification as well as efforts to increase the accuracy and convenience of the manual. • Contact our agents or customer service center if you have problems during the use. www.ssinverter.info Safety Information and Precautions SSI700 User Manual Introduction Compared with SSI700, the SSI900 series AC drive incorporates the following improvements: 1) Multiple voltage classes It provides coverage of single-phase 220 V, three-phase 220 V, three-phase 380 V . 2) Control of asynchronous motor It supports vector control of three-phase AC asynchronous motor. 3) Diversified control modes It supports control modes, namely, sensorless flux vector control (SFVC) and V/F control. 4) communication protocols It supports communication via Modbus-RTU . 5) Other new functions The newly added functions of the SSI700 series AC drive are described as below: Function Virtual I/O Rapid current limit Function Restoring user parameters Higher-accuracy AI/AO Customized parameter display Modified parameter display Operation selection at fault occurrence PID parameters switchover PID feedback loss detection DI/DO positive or negative logic DI/DO response delay Power dip ride through Timing operation Description It can implement various simple logic functions. It helps to avoid frequent occurrence of overcurrent faults of the AC drive. Description It allows you to save or restore the parameters set by yourself. The AI/AO accuracy can reach almost 20 mv via factory correction or on-site correction. You can customize the parameters that need to be displayed. You can view the modified parameters. You can select the reaction of the AC drive to a fault occurring, based on the actual need. The reactions are as below: • Coast to stop • Decelerate to stop • Continue to run You can also select the frequency at which the AC drive continues to run. Two groups of PID parameters can be switched over via terminals or can be automatically switched over according to deviation. The PID feedback loss value can be set to realize PID protection. You can set the DI/DO positive or negative logic. You can set DI/DO response delay time. It ensures that the AC drive continues to run for a short time when an instantaneous power failure or sudden voltage reduction occurs. The AC drive supports timing operation for 6500 minutes at maximum. www.ssinverter.info SSI700 User Manual Product Checking Upon unpacking, check: • Whether the nameplate model and AC drive ratings are consistent with your order. The box contains the AC drive, certificate of conformity, user manual and warranty card. • Whether the AC drive is damaged during transportation. If you find any omission or damage, contact Ssinverter or your supplier immediately. First-time Use For the users who use this product for the first time, read the manual carefully. If in doubt concerning some functions or performances, contact the technical support personnel of Ssinverter to ensure correct use. CE Mark The CE mark on the declares that the AC drive complies with the European low voltage directive (LVD) and EMC directive. The SSI700 series AC drive complies with the following LVD and EMC directives and standards: The SSI700 series AC drive complies with the requirements of standard IEC/EN 61800-3 on the condition of correct installation and use by following the instructions in chapter 7. Contents Preface 1 Introduction 2 Chapter 1 Safety Information and Precautions 1.1 Safety Information 1.2 General Precautions 1 3 Chapter 2 Product Information 2.1 Designation Rules and Nameplate of the SSI700 2.2 Components of the SSI700 2.3 Technical Specifications 2.4 Peripheral Electrical Devices and System Configuration 1 1 1 3 Chapter 3 Mechanical and Electrical Installation 3.1 Mechanical Installation 3.2 Electrical Installation 1 2 Chapter 4 Operation, Display and Application Examples 4.1 Operation Panel 4.2 Viewing and Modifying Function Codes 4.3 Definition and Operation of the Multifunction Key (APP) 4.4 Viewing Status Parameters 4.5 Starting or Stopping the AC Drive 4.6 Setting the Running Frequency 4.7 Setting and Auto-tuning of Motor Parameters 4.8 Use of DI Terminals 4.9 Use of DO Terminals 4.10 Use of AI Terminals 1 2 3 3 6 11 17 19 20 20 www.ssinverter.info SSI700 User Manual 4.11 Use of AO Terminals 4.12 Use of Serial Communication 4.13 Password Setting 4.14 Parameter Saving and Default Setting Restoring 20 21 21 22 Chapter 5 Function Code Table 5 Standard Function Parameters 1 Chapter 6 Description of Function Codes Group P0: Basic Parameters Group P1: Motor 1 Parameters Group P2: Vector Control Parameters Group P3: V/F Control Parameters Group P4: Input Terminals Group P5: Output Terminals Group P6: Start/Stop Control Group P7: Operation Panel and Display Group P8: Auxiliary Functions Group P9: Fault and Protection Group 10: Process Control PID Function Group 11: Swing Frequency, Fixed Length and Count Group 12: Multi-Reference and Simple PLC Function Group 13: Point-point Communication Group 16: User Password Group 17: Torque Control and Restricting Parameters 1 9 10 13 15 23 27 32 37 47 53 58 60 63 63 64 Chapter 7 EMC 7.1 Definition of Terms 7.2 Introduction to EMC Standard 7.3 Selection of Peripheral EMC Devices 7.4 Shielded Cable 7.5 Solutions to Common EMC Interference Problems 1 1 2 3 5 Chapter 8 Selection and Dimensions 8.1 Electrical Specifications of the SSI700 8.2 Physical Appearance and Overall Dimensions of the SSI700 8.3 Physical Dimensions of External Operation Panel 8.4 Selection of Braking Resistor 1 1 2 3 Chapter 9 Maintenance and Troubleshooting 9.1 Routine Repair and Maintenance of the SSI700 9.2 Warranty Agreement 9.3 Faults and Solutions 9.4 Common Faults and Solutions 1 2 2 5 www.ssinverter.info Product Information SSI700 User Manual Product Information Chapter 2 Product Information 2.1 Designation Rules and Nameplate of the SSI700 Figure 2-1 Designation rules and nameplate of the SSI700 2.2 Components of the SSI700 The SSI700 series AC drives have two housing types, plastic housing according to different voltage and power classes. 2.3 Technical Specifications Table 2-1 Technical specifications of the SSI700 Item Maximum frequency Carrier frequency Input frequency resolution Standard functions Control mode Startup torque Speed range Speed stability accuracy Overload capacity Torque boost V/F curve Specifications • Vector control: 0–320 Hz • V/F control: 0–3200 Hz 0.5–16 kHz The carrier frequency is automatically adjusted based on the load features. Digital setting: 0.01 Hz Analog setting: maximum frequency x 0.025% • Sensorless flux vector control (SFVC) • Voltage/Frequency (V/F) control • G type: 0.5 Hz/150% (SFVC) 1:100 (SFVC) • ± 0.5% (SFVC) • G type: 60s for 150% of the rated current, 3s for 180% of the rated current • Fixed boost • Customized boost 0.1%–30.0% • Straight-line V/F curve • Multi-point V/F curve • N-power V/F curve (1.2-power, 1.4-power, 1.6-power, 1.8-power, square) www.ssinverter.info SSI700 User Manual Product Information Enironment Display and operation RUN Individualized functions Standard functions Item V/F separation Specifications Two types: complete separation; half separation • Straight-line ramp • S-curve ramp Ramp mode Four groups of acceleration/deceleration time with the range of 0.0–6500.0s DC braking frequency: 0.00 Hz to maximum frequency DC braking Braking time: 0.0–36.0s Braking action current value: 0.0%–100.0% JOG frequency range: 0.00–50.00 Hz JOG control JOG acceleration/deceleration time: 0.0–6500.0s Onboard multiple It implements up to 16 speeds via the simple PLC function or preset speeds combination of DI terminal states. Onboard PID It realizes process-controlled closed loop control system easily. Auto voltage It can keep constant output voltage automatically when the mains regulation (AVR) voltage changes. Overvoltage/ The current and voltage are limited automatically during the Overcurrent stall running process so as to avoid frequent tripping due to control overvoltage/overcurrent. Torque limit and It can limit the torque automatically and prevent frequent over control current tripping during the running process. • Operation panel • Control terminals Running • Serial communication port command source You can perform switchover between these sources in various ways. There are a total of 10 frequency sources, such as digital setting, analog voltage setting, analog current setting, pulse Frequency source setting and serial communication port setting. You can perform switchover between these sources in various ways. Auxiliary There are ten auxiliary frequency sources. It can implement fine frequency source tuning of auxiliary frequency and frequency synthesis. 5 digital input (DI) terminals, one of which supports up to 100 kHz high-speed pulse input Input terminal 2 analog input (AI) terminals, one of which only supports 0–10 V voltage input and the other supports 0–10 V voltage input or 4–20 mA current input. 1 high-speed pulse output terminal (open-collector) that supports 0–100 kHz square wave signal output 1 digital output (DO) terminal Output terminal 1 relay output terminal 1 analog output (AO) terminal that supports 0–20 mA current output or 0–10 V voltage output LED display It displays the parameters. Key locking and It can lock the keys partially or completely and define the function selection function range of some keys so as to prevent mis-function. Motor short-circuit detection at power-on, output phase loss protection, overcurrent protection, overvoltage protection, Protection mode undervoltage protection, overheat protection and overload protection Installation location: Indoor, free from direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapour, drip or salt. Altitude: Lower than 1000 m Ambient temperature: -10°C to +40°C (de-rated if the ambient temperature is between 40°C and 50°C) Humidity: Less than 95%RH, without condensing Vibration: Less than 5.9 m/s2 (0.6 g) Storage temperature: -20°C to +60°C IP level: IP20 Pollution degree: PD2 Power distribution System: TN , TT www.ssinverter.info SSI700 User Manual Product Information 2.4 Peripheral Electrical Devices and System Configuration When the SSI700 is used to control the synchronous or asynchronous motor, forming a control system, it is necessary to install various electrical devices on the input and output sides of the AC drive to ensure the system safety and stability. Figure 2-2 System configuration of three-phase 220 V/380 V voltage class, 2.2 Kw and above 2.4.1 Description of Peripheral Electrical Devices Table 2-2 Description of peripheral electrical devices Part Mounting Location MCCB Power receiving side Contactor Between MCCB and AC drive input side AC input reactor AC drive input side Function Description Interrupt the power supply when overcurrent occurs on down stream devices Start and stop the AC drive. Do not start and stop the AC drive frequently by switching the contactor on and off (less than twice per minute) nor use it to directly start the AC drive. • Improve the power factor of the input side. • Eliminate the higher harmonics of the input side effectively and prevent other devices from being damaged due to distortion of the voltage waveform. • Eliminate the input current unbalance due to unbalance between the power phases. www.ssinverter.info SSI700 User Manual Part Product Information Mounting Location EMC Input filter AC drive input side AC output reactor Between AC drive output side and the motor, close to the AC drive Function Description • Reduce the external conduction and radiation interference of the AC drive. • Decrease the conduction interference flowing from the power end to the AC drive and improve the anti interference capacity of the AC drive. The output side of the AC drive generally has much higher harmonics. When the motor is far from the AC drive, there is much distributed capacitance in the circuit and certain harmonics may cause resonance in the circuit, bringing about the following two impacts: • Degrade the motor insulation performance and damage the motor in the long run. • Generate large leakage current and cause frequent AC drive protection trips. If the distance between the AC drive and the motor is greater than 50 m, install an AC output reactor. 1) Do not install the capacitor or surge suppressor on the output side of the AC drive. Otherwise, it may cause faults to the AC drive or damage to the capacitor and surge suppressor. 2) Inputs/Outputs (main circuit) of the AC drive contain harmonics, which may interfere with the communication device connected to the AC drive. Therefore, install an antiinterference filter to minimize the interference. 3) For more details on peripheral devices, refer to related selection manual. 2.4.2 Description of Optional Parts The optional parts include braking unit of different functions and external operation panel, etc. If any optional part is required, specify it in your order. Table 2-3 Optional parts of the SSI700 Name Model Internal braking unit AC drive model followed External LED operation panel panel Function The models of single-phase (0.4–2.2 kW) and three-phase (0.75–15 kW) are installed with the internal braking unit as standard configuration. It supports LED display and operations. Remark Internal braking unit. It applies to the SSI700 series AC drives. www.ssinverter.info Mechanical and Electrical Installation SSI700 User Manual Mechanical and Electrical Installation Chapter 3 Mechanical and Electrical Installation 3.1 Mechanical Installation 3.1.1 Installation Environment Requirements Item Ambient temperature Heat dissipation Mounting location Vibration Protective enclosure Requirements -10°C to +50°C Install the AC drive on the surface of an incombustible object, and ensure that there is sufficient space around for heat dissipation. Install the AC drive vertically on the support using screws. Free from direct sunlight, high humidity and condensation Free from corrosive, explosive and combustible gas Free from oil dirt, dust and metal powder Less than 0.6 g Far away from the punching machine or the like The SSI700 series AC drives of plastic housing are the whole unit built-in products operated through remote control and need to be installed in the final system.The final system must have the required fireproof cover, electrical protective cover and mechanical protective cover, and satisfy the regional laws & regulations and related IEC requirements. 3.1.2 Installation Clearance Requirements The clearance that needs to be reserved varies with the power class of the SSI700, as shown in the following figure. Figure 3-1 Clearance around the SSI700 for installation The SSI700 series AC drive dissipates heat from the bottom to the top. When multiple AC drives are required to work together, install them side by side. For application installing multiple AC drives, if one row of AC drives need to be installed above another row, install an insulation guide plate to prevent AC drives in the lower row from heating those in the upper row and causing faults. www.ssinverter.info SSI700 User Manual Mechanical and Electrical Installation ■ Installation Precautions 1) Reserve the installation clearances as specified in Figure 3-1 to ensure sufficient space for heat dissipation. Take heat dissipation of other parts in the cabinet into consideration. 2) Install the AC drives upright to facilitate heat dissipation. If multiple AC drives are installed in the cabinet, install them side by side. If one row of AC drives need to be installed above another row, install an insulation guide plate . 3) Use incombustible hanging bracket. 3.2 Electrical Installation 3.2.1 Description of Main Circuit Terminals ■ Description of Main Circuit Terminals of Three-phase AC drive www.ssinverter.info SSI700 User Manual Mechanical and Electrical Installation Table 3-1 Description of main circuit terminals of three-phase AC drive Terminal Name Three-phase power supply input terminals B1, B2 Connecting terminals of braking resistor U, V, W AC drive output terminals Description Connect to the single-phase 220 VAC power supply. Connect to the braking resistor for the AC drive of 2.2 kW and below (220 V) and 7.5 kW and below (other voltage classes). Connect to a three-phase motor. Grounding terminal Must be grounded. R, S , T 3.2.2 Wiring of AC Drive Main Circuit ■ Precautions on the Wiring 1) Power input terminals R, S, T – The cable connection on the input side of the AC drive has no phase sequence requirement. – The specification and installation method of external power cables must comply with the local safety regulations and related IEC standards. – Use copper conductors of a proper size as power cables according to the recommended values in section 8.3. 2) Braking resistor connecting terminals B1 , B2 – The connecting terminals of the braking resistor are effective only for the AC configured with the built-in braking unit. – The cable length of the braking resistor shall be less than 5 m. Otherwise, it may damage the AC drive. 3) AC drive output terminals U, V, W – The specification and installation method of external power cables must comply with the local safety regulations and related IEC standards. – Use copper conductors of a proper size as power cables according to the recommended values in section 8.3. – The capacitor or surge absorber cannot be connected to the output side of the AC drive. Otherwise, it may cause frequent AC drive fault or even damage the AC drive. – If the motor cable is too long, electrical resonance will be generated due to the impact of distributed capacitance. This will damage the motor insulation or generate higher leakage current, causing the AC drive to trip in overcurrent protection. If the motor cable is greater than 100 m long, an AC output reactor must be installed close to the AC drive. 4) Terminal PE – This terminal must be reliably connected to the main earthing conductor. Otherwise, it may cause electric shock, mal-function or even damage to the AC drive. – Do not connect the earthing terminal to the neutral conductor of the power supply. – The impedance of the PE conductor must be able to withstand the large shortcircuit current that may arise when a fault occurs. – Select the size of the PE conductor according to the following table: Cross-sectional Area of a Phase Conductor (S) S ≤ 16 mm2 16 mm2 < S ≤ 35 mm2 35 mm2 < S Min. Cross-sectional Area of Protective Conductor (Sp) S 16 mm2 S/2 www.ssinverter.info SSI700 User Manual Mechanical and Electrical Installation – You must use a yellow/green cable as the PE conductor. 5) Requirements on upstream protection device – Install upstream protection device on the input power circuit. The protection device must provide the protections on overcurrent, short-circuit and electrical solation. – When selecting the protective device, you should consider the current capacity of the power cable, system overload capacity and short-circuit capacity of the upstream power distribution of the equipment. Generally, make selection according to the recommended values in section 8.4. 3.2.3 Description of Control Circuit Terminals [ ■ Terminal Arrangement of Control Circuit ■ Description of Control Circuit Terminals Table 3-3 Description of control circuit terminals Analog output Digital input Analog input Power supply Type Terminal Name Function Description Provide +10 V power supply to external unit. Generally, it provides power supply to external potentiometer with resistance range of 1–5 kΩ. Maximum output current: 10 mA Provide +24 V power supply to external unit. Generally, it provides power supply to DI/DO terminals and external sensors. Maximum output current: 20 mA Connect to +24 V by default. Input voltage range: 0–10 VDC Impedance: 22 kΩ Input range: 0–10 VDC/4–20 mA, decided by jumper J8 on the control board Impedance: 22kΩ (voltage input), 500 Ω (current input) +10V-GND External +10 V power supply +24V-COM External +24V power supply AI1-GND Analog input 1 AI2-GND Analog input 2 DI1 DI2 DI3 DI4 Digital input 1 Digital input 2 Digital input 3 Digital input 4 Optical coupling isolation, compatible with dual polarity input Impedance: 2.4 kΩ Voltage range for level input: 9–30 V DI5 High-speed pulse input Besides features of DI1–DI4 and DI6, it can be used for high-speed pulse input. Maximum input frequency: 100 kHz Analog output 1 Voltage or current output is decided by jumper J5. Output voltage range: 0–10 V Output current range: 0–20 mA AO1-GND www.ssinverter.info SSI700 User Manual Relay output Digital output Type Terminal Mechanical and Electrical Installation Name DO1-CME Digital output 1 FM- CME High-speed pulse output T/A-T/B NC terminal T/A-T/C COM NO terminal Digital grounding Function Description Optical coupling isolation, dual polarity open collector output Output voltage range: 0–24 V Output current range: 0–50 mA Note that CME and COM are internally insulated, but they are shorted by jumper externally. In this case DO1 is driven by +24 V by default. If you want to drive DO1 by external power supply, remove the jumper. It is limited by P5-00 (FM terminal output mode selection). As high-speed pulse output, the maximum frequency hits 100 kHz. As open-collector output, its specification is the same as that of DO1 Contact driving capacity: 250 VAC, 3 A, COSø = 0.4 30 VDC, 1 A Applying to Overvoltage Category II circuit Please use twisted pair cable or screening wire 3.2.4 Wiring of AC Drive Control Circuit Figure 3-3 Wiring mode of the AC drive control circuit Note • All SSI700 series AC drives have the same wiring mode. The figure here shows the wiring of Three-phase 220~380 VAC drive. ◎ indicates main circuit terminal, while ○ indicates control circuit terminal. www.ssinverter.info SSI700 User Manual Mechanical and Electrical Installation ■ Description of Wiring of Signal Terminals 1) Wiring of AI terminals Weak analog voltage signals are easy to suffer external interference, and therefore the shielded cable must be used and the cable length must be less than 20 m, as shown in following figure. Figure 3-4 Wiring mode of AI terminals In applications where the analog signal suffers severe interference, install filter capacitor or ferrite magnetic core at the analog signal source. Figure 3-5 Install filter capacitor or ferrite magnetic core 2) Wiring of DO terminal When the digital output terminal needs to drive the relay, an absorption diode shall be installed between two sides of the relay coil. Otherwise, it may cause damage to the 24 VDC power supply. The driving capacity is not more than 50 mA. Note Do not reverse the polarity of the absorption diode during installation, as shown in Figure 3-3. Otherwise, the 24 VDC power supply will be damaged immediately once there is digital output. Figure 3-6 DO terminal wiring diagram www.ssinverter.info Operation, Display and Application Examples SSI700 User Manual Operation, Display and Application Example Chapter 4 Operation, Display and Application Examples 4.1 Operation Panel You can modify the parameters, monitor the working status and start or stop the SSI700 by operating the operation panel, as shown in the following figure. Figure 4-1 Diagram of the operation panel 4.1.1 Description of Indicators • RUN ON indicates that the AC drive is in the running state, and OFF indicates that the AC drive is in the stop state. • LOCAL/REMOT It indicates whether the AC drive is operated by means of operation panel, terminals or communication. LOCAL/REMOT: OFF LOCAL/REMOT: ON LOCAL/REMOT: blinking • Operation panel control Terminal control Communication control FWD/REV ON indicates reverse rotation, and OFF indicates forward rotation. • TUNE/TC When the indicator is ON, it indicates torque control mode. When the indicator is blinking slowly, it indicates the auto-tuning state. When the indicator is blinking quickly, it indicates the fault state. • Unit Indicators www.ssinverter.info SSI700 User Manual Operation, Display and Application Example • Digital Display The 5-digit LED display is able to display the set frequency, output frequency, monitoring data and fault codes. 4.1.2 Description of Keys on the Operation Panel Table 4-1 Description of keys on the operation panel Key Name Function Programming Enter or exit Level I menu. Confirm Enter the menu interfaces level by level, and confirm the parameter setting. Increment Increase data or function code. Decrement Decrease data or function code. Shift Select the displayed parameters in turn in the stop or running state, and select the digit to be modified when modifying parameters. RUN Start the AC drive in the operation panel control mode. Stop/Reset Stop the AC drive when it is in the running state and perform the reset operation when it is in the fault state. The functions of this key are restricted in P7-02. Multifunction Perform function switchover (such as quick switchover of command source or direction) according to the setting of P7-01. AI0 Potentiometer on the key pad 4.2 Viewing and Modifying Function Codes The operation panel of the SSI700 adopts three-level menu. The three-level menu consists of function code group (Level I), function code (Level II), and function code setting value (level III), as shown in the following figure. Figure 4-2 Operation procedure on the operation panel www.ssinverter.info SSI700 User Manual • After you press Operation, Display and Application Example , the system saves the parameter setting first, and then goes back to Level II menu and shifts to the next function code. • After you press , the system does not save the parameter setting, but directly returns to Level II menu and remains at the current function code. Here is an example of changing the value of P3-02 to 15.00 Hz. Figure 4-3 Example of changing the parameter value In Level III menu, if the parameter has no blinking digit, it means that the parameter cannot be modified. This may be because: • Such a function code is only readable, such as, AC drive model, actually detected parameter and running record parameter. • Such a function code cannot be modified in the running state and can only be changed at stop. 4.3 Definition and Operation of the Multifunction Key (APP) You can define the function (command source switchover or rotation direction switchover) of the multifunction key in P7-01. For details, see the description of P7-01. 4.4 Viewing Status Parameters In the stop or running state, you can press on the operation panel to display status parameters. Whether parameters are displayed is determined by the binary bits of values converted from the values of P7-03, P7-04, and P7-05 in the hexadecimal format. In stop state, a total of 13 status parameters can be displayed, as listed in the following table. www.ssinverter.info SSI700 User Manual Function Code Parameter Name Operation, Display and Application Example Setting Range Default Group P7: Operation Panel and Display P7-05 LED display stop parameters 0 If a parameter needs to be displayed during the running, set the corresponding bit to 1, and set P7-05 to the hexadecimal equivalent of this binary number. In running state, five running status parameters are displayed by default, and you can set whether other parameters are displayed by setting P7-03 and P7-04, as listed in the following table. www.ssinverter.info SSI700 User Manual Function Code Parameter Name Operation, Display and Application Example Setting Range Default Group P7: Operation Panel and Display P7-03 LED display running parameters 1 1F P7-04 LED display running parameters 2 0 If a parameter needs to be displayed during the running, set the corresponding bit to 1, and set P7-03 to the hexadecimal equivalent of this binary number. www.ssinverter.info SSI700 User Manual Operation, Display and Application Example When the AC drive is powered on again after power failure, the parameters that are selected before power failure are displayed. Select the required parameters by pressing referring to the following example. . Set the values of the parameters by 1. Determine the parameters to be displayed. Running frequency, Bus voltage, Output voltage, Output current, Output frequency, Output torque, PID feedback, Encoder feedback speed 2. Set the binary data. P7-03: 0000 0000 0111 1101B, P7-04: 0010 0000 0000 0001B 3. Convert the binary data to hexadecimal data: P7-03: 007DH, P7-04: 2001H The values displayed on the operation panel are respectively H.1043 and H.2001 respectively for P7-03 and P7-04. 4.5 Starting or Stopping the AC Drive 4.5.1 Selecting the Start/Stop Command Source There are three start/stop command sources, namely, operation panel control, terminal control, and communication control. You can select the command source in P0-01. Function Code Parameter Name Setting Range Default Property 0 ☆ Group P0: Standard Function Parameters 0:Operation panel control (LED off) P0-01 Command source selection Run/Stop 1: Terminal control (LED on) 2: Communication control (LED blinking) It is used to determine the input channel of the AC drive control commands, such as run, stop, forward rotation, reverse rotation and jog operation. You can input the commands in the following three channels: • 0: Operation panel control ("LOCAL/REMOT" indicator off) Commands are given by pressing keys and on the operation panel. • 1: Terminal control ("LOCAL/REMOT" indicator on) Commands are given by means of multifunctional input terminals with functions such as FWD, REV, JOGF, and JOGR. This control mode is applicable to scenarios where the DIP switch or electromagnetic button is used to start or stop the application system or scenarios where the dry contact signal is used to start or stop the AC drive. The switch signal mode is set in P4-11. The input terminal of the start/stop signal is set in P4-00 to P4-09. For details, see the description of P4-11 and P4-00 to P4-09. Example 1: To use the DIP switch as the start/stop source, and allocate the forward rotation switch signal to DI2 and the reverse rotation switch signal to DI3, perform the setting as shown in the following figure. www.ssinverter.info SSI700 User Manual Operation, Display and Application Example Figure 4-6 Setting of using the DIP switch for start/stop In the preceding figure, when SW1 is ON, the AC drive instructs forward rotation; when SW1 is OFF, the AC drive stops. When SW2 is ON, the AC drive instructs reverse running; when SW2 is OFF, the AC drive stops. If SW1 and SW2 are ON or OFF simultaneously, the AC drive stops. Example 2: To use the electromagnetic button as the start/stop source, and allocate the startup signal to DI2, stop signal to DI3 and reverse rotation signal to DI4, perform the setting as shown in the following figure. Figure 4-7 Setting of using the electromagnetic button for start/stop In the preceding figure, SB1 must stay ON during normal start and running. The AC drive stops immediately after SB1 becomes OFF. The signals from SB2 and SB3 become valid once they become ON. The running state of the AC drive is determined by the final actions on the three buttons. 2: Communication control The most common configuration is when the host computer is used to control running of the AC drive by means of communication, such as the RS485. The SSI700 interacts with the user programmable also by means of communication. Figure 4-8 Setting for start/stop using the communication control mode When 13-04 is set to a non-zero number, the function of automatic AC drive stop upon communication timeout is enabled. This prevents uncontrollable AC drive running due to faults of the communication cable or the host computer. www.ssinverter.info SSI700 User Manual Operation, Display and Application Example The communication port of the AC drive supports the Modbus-RTU protocol, and the communication is implemented only when the host computer supports the Modbus- RTU master station protocol. 4.5.2 Start Mode The SSI700 supports three start modes, namely, direct start, rotational speed tracking restart, and pre-excited start (asynchronous motor), set in P6-00. • P6-00 = 0 (direct start) It is applicable to small-inertia load. The frequency curve in this mode is shown in the following figure. DC braking before the start is applicable to drive of load such as elevator and crane. Startup frequency is applicable to drive with burst start under start torque, such as cement mixer. Figure 4-9 Frequency curve of direct start P6-00 = 1 (Rotational speed tracking restart) It is applicable to large-inertia load. The frequency curve in this mode is shown in the following figure. If the load motor is still rotating due to the inertia when the AC drive starts, this mode is used to prevent start overcurrent. Figure 4-10 Frequency curve of rotational speed tracking restart • P6-00 = 2 (Pre-excited start) It is applicable only to inductive asynchronous motor. The AC drive performs preexcitation before start, improving quick response of the motor and meeting the requirements of short acceleration time. The frequency curve in this mode is shown in the following figure. www.ssinverter.info SSI700 User Manual Operation, Display and Application Example Figure 4-11 Frequency curve of pre-excited start 4.5.3 Stop Mode The AC drive supports two stop modes, decelerate to stop and coast to stop, set in P6-10. Figure 4-12 Diagram of two stop modes (decelerate to stop and coast to stop) 4.5.4 Timing Stop The SSI700 supports timing stop. This function is enabled by P8-42 and the timing duration is determined by P8-43 and P8-44. Figure 4-13 Setting of the timing stop function You can set the timing duration by means of analog input (such as potentiometer signal). For details, see the description of P8-43. 4.5.5 JOG Running In certain applications, the AC drive needs to run in low speed temporarily to facilitate equipment test or other commissioning operations. In this case, you can set the AC drive to perform JOG running. www.ssinverter.info SSI700 User Manual Operation, Display and Application Example Figure 4-14 JOG running ■ Parameter Setting and Operation of JOG Running in Operation Panel Control Figure 4-15 JOG running in operation panel control Set the parameters according to the preceding figure. In stop state of the AC drive, hold down , and the AC drive starts JOG running. After you release , the AC drive decelerates to stop. To perform reverse JOG, set P7-01 to 4 and P8-13 to 1. Hold down and the AC drive starts reverse JOG running. ■ Parameter Setting and Operation of JOG Running in DI Terminal Control For equipment that requires frequent JOG operations, such as textile machine, it is more convenient to control JOG running by using keys or buttons. To achieve convenient control, perform the setting according to the following figure. Figure 4-16 JOG running in DI terminal control www.ssinverter.info SSI700 User Manual Operation, Display and Application Example After performing the setting according to the preceding figure, press the FJOG button in stop state of the AC drive. Then, the AC drive starts forward JOG. After you press the FJOG button again, the AC drive decelerates to stop. 4.6 Setting the Running Frequency The AC drive provides two frequency sources, namely, main frequency source A and auxiliary frequency source B. You can select one frequency source and switch over between the two sources. You can also perform superposition on the two sources by setting the calculation formula to meet different control requirements of different scenarios. 4.6.1 Frequency Setting by the Main Frequency Source There are nine setting modes of main frequency sources, digital setting (UP/DOWN modification, non-retentive at power failure), digital setting (UP/DOWN modification, retentive at power failure), AI1, AI2, pulse setting, multi-reference, simple PLC, and communication setting. You can select one in P0-03. Figure 4-17 Frequency set by the main frequency source According to the preceding figure, the running frequency of the AC drive can be set by means of function codes, manual adjustment, analog input, multi-speed terminal, external feedback signal, internal PID regulator, or the host computer. Set the corresponding function codes of each frequency setting mode, as shown in the preceding figure. 4.6.2 Frequency Setting by the Auxiliary Frequency Source The frequency setting by the auxiliary frequency source is the same as the frequency setting by the main frequency source. You can set the auxiliary frequency source in P0-04. Figure 4-18 Frequency set by the auxiliary frequency source www.ssinverter.info SSI700 User Manual Operation, Display and Application Example The relationship between the target running frequency and the main frequency source and auxiliary frequency source is set in P0-07, as follows: 1) Main frequency source A: The main frequency source is directly used to set the target running frequency. 2) Auxiliary frequency source B: The auxiliary frequency source is directly used to set the target running frequency. 3) A and B operation: There are four operation methods, namely, A+B, A-B, maximum of A and B, and minimum of A and B. 4) Frequency switchover: A DI terminal is used to switch over between the preceding three frequency setting channels. The following figure shows how to set the relationship in P0-07, in which the bold line indicates the default setting. Figure 4-19 Relationship between the target running frequency and main and auxiliary frequency sources The operation between the main frequency source and the auxiliary frequency source can be used for closed-loop speed control. For example, using the main frequency source for setting the required frequency and the auxiliary frequency source for automatic adjustment, in conjunction with switchover performed by the external DI terminal signal, the required control can be implemented. www.ssinverter.info SSI700 User Manual Operation, Display and Application Example 4.6.3 Binding Command Source to Frequency Source The three command sources can be separately bound to frequency sources, as shown in Figure 4-19. When the specified command source (P0-01) is bound to a frequency source (corresponding digit in the value of P0-27), the frequency is determined by the frequency setting channel set in P0-27. In this case, both main and auxiliary frequency sources are ineffective. 4.6.4 AI as the Frequency Source The AI terminal can be used as the frequency source. The SSI700 provides two AI terminals (AI1 and AI2) on the control board . The following figures show how to use the AI as the frequency source. Figure 4-20 Voltage input of AI1 connected to the potentiometer as the frequency source (2–10 V corresponding to 10–40 Hz) Figure 4-21 Current input of AI2 connected to 4DA module of the PLC as the frequency source (4–20 mA corresponding to 0–50 Hz) Notes 1. AI1 provides 0–10 V voltage input. AI2 provides 0–10 V voltage input or 4–20 mA current input, determined by jumper J8 on the control board. 2. When AI is used as the frequency source, 100% of the voltage or current input corresponding setting corresponds to the maximum frequency in P0-10. 3. SSI700 provides five corresponding relationship curves, which can be selected in P4-33. The input values and corresponding settings of each curve are set in P4-13 to P4-27 . 4.6.5 Pulse Setting as the Frequency Source In many scenarios, pulse input is used as the frequency source. The specifications of pulse signals are: voltage 9–30 V, frequency 0–100 kHz. Only DI5 can be used for pulse input. The relationship between pulse input from DI5 and the corresponding setting is set in P4-28 to P4-31. The relationship is a two-point line, and www.ssinverter.info SSI700 User Manual Operation, Display and Application Example 100% of pulse input corresponding setting corresponds to the maximum frequency of P0-10, as shown in Figure 4-22. Figure 4-22 Pulse setting as the frequency source 4.6.6 Frequency Closed-Loop Control The SS700 has a built-in PID regulator. Together with the frequency sources, the PID regulator can implement automatic adjustment of progress control, such as constant temperature, constant pressure, and tension control. Figure 4-23 Automatic adjustment by PID regulator When PID frequency closed-loop control is implemented, P0-03 (Main frequency source A selection) must be set to 8 (PID). The PID-related parameters are set in group 10, as shown in Figure 4-23. The SSI900 has two built-in equivalent PID calculating units. You can set the features, such as adjustment speed and accuracy, for the two units separately based on the actual conditions. Switchover between the two units can be implemented automatically or by means of an external DI terminal. 4.6.7 Multi-Speed Mode In scenarios where the running frequency of the AC drive need not be adjusted continuously and only several frequencies are required, the multi-speed control can be used. The SSI700 supports a maximum of 16 running frequencies, which are implemented by state combinations of four DI terminals. Set the function codes corresponding to DI terminals to a value among 12 to 15, and then the DI terminals are specified as the multi-frequency input terminals. The multiple frequencies are set based on the multi-frequency table in group 12. In addition, you need to set P0-03 (Main frequency source A selection) to 6 (Multireference). The following figure shows how to set the multi-speed function. www.ssinverter.info SSI700 User Manual Operation, Display and Application Example Figure 4-24 Setting the multi-speed function In the preceding figure, DI7, DI4, DI8, and DI2 are used as the multi-frequency input terminals, each of which has a bit value. The state combinations of these terminals correspond to multiple frequencies, When (DI7, DI4, DI8, DI2) = (0, 0, 1, 0), the state combination value is 2, corresponding to the value set in 12-02. The target running frequency is automatically calculated by 12-02 x P0-10. The SSI700 supports a maximum of four DI terminals to be used as the multi-frequency input terminals. You can also use less than four DI terminals, and the empty bit is considered to be 0. 4.6.8 Setting the Motor Rotating Direction After the AC drive restores the default settings, press to drive the motor to rotate. In this case, the rotating direction is regarded as the forward rotation. If the rotating direction is reverse to the direction required by the equipment, power off the AC drive and exchange any two of the output UVW cables (wait until the main capacitor of the AC drive is completely discharged). In some applications where both forward rotation and reverse rotation are required, enable the reverse control (P8-13 = 0, default value) and meanwhile reverse the rotating direction by setting P0-09 to 1. Then press to make the motor rotate in the reverse direction, as shown in the following figure. Figure 4-25 Reversing the motor rotating direction If the command source is terminal control and reverse rotation is required, use the default value 0 of P8-13 to enable reverse control. www.ssinverter.info SSI700 User Manual Operation, Display and Application Example According to the preceding figure, when the running frequency of the AC drive is set by means of communication (P0-03 = 9) and reverse control is enabled (P8-13 = 0), the AC drive instructs the reverse direction if the set frequency Fs is a negative value. If the give running command is reverse rotation or the set frequency is a negative value, but reverse control is disabled (P8-13 =1), the AC drive will run at 0 Hz and has no output. In some applications where reverse rotation is prohibited, do not change the rotating direction by modifying the function codes because the function codes will be restored once the AC drive restores the default settings. 4.6.9 Setting the Fixed Length Control Mode The SSI700 has the fixed length control function. The length pulses are sampled by the DI allocated with function 27 (Length count input). The "Actual length" (11-06) is obtained by dividing the number of pulses sampled by the value of 11-07 (Number of pulses per meter). If the actual length is larger than the "Set length" (11-05), the multifunctional DO terminal becomes ON. In the process of fixed length control, the length can be reset by means of the DI terminal allocated with function 28 (Length reset). The related setting is shown in the following figure. Figure 4-26 Function code setting for fixed length control Notes • In the fixed length control mode, the direction cannot be identified and only the length shall be calculated based on the number of pulses. • Only DI5 can be allocated with the function "Length count input". • An automatic stop system can be implemented if the length reached signal output by the DO is fed back to the AC drive input terminal with the stop function. Figure 4-27 Common application example of the fixed length control function www.ssinverter.info SSI700 User Manual Operation, Display and Application Example 4.6.10 Use of the Counting Function The count value needs to be collected by the DI terminal that is allocated with function 25. When the count value reaches 11-08 (Set count value), the DO terminal allocated with function 8 (Set count value reached) becomes ON. Then the counter stops counting. When the count value reaches 11-09 (Designated count value), the DO terminal allocated with function 9 (Designated count value reached) becomes ON. The counter continues to count until "Set count value" is reached. Figure 4-28 Parameter setting in the counting mode Notes • 11-09 (Designated count value) must not be greater than 11-08 (Set count value). • DI5 must be used when the pulse frequency is high. • The DO terminal that is allocated with function 9 (Designated count value reached) and the DO terminal that is allocated with function 8 (Set count value reached) must not be the same. • In the RUN/STOP state of the AC drive, the counter will not stop until "Set count value" is reached. • The count value is retentive at power failure. • An automatic stop system can be implemented if the signal output by the DO terminal with the function (Count value reached) is fed back to the DI terminal of the AC drive with stop function. 4.7 Setting and Auto-tuning of Motor Parameters 4.7.1 Motor Parameters to Be Set When the AC drive runs in the vector control mode (P0-00 = 0 or 1), accurate motor parameters are required to ensure desired driver performance and running efficiency. This is extremely different from the V/F control (P0-00 = 1). Motor parameters (motor 1 by default) that need to be set are listed in the following table. Table 4-2 Motor parameters to be set www.ssinverter.info SSI700 User Manual Operation, Display and Application Example Parameter P1-00 P1-01 to P1-05 P1-06 to P1-10 Description Remark Asynchronous motor, variablefrequency asynchronous motor, Motor type Rated motor power, Rated motor voltage, Rated motor current, Rated motor frequency, Rated motor rotational speed Motor internal equivalent stator resistance, inductive reactance and rotor inductance Model parameters, manual input Auto-tuning parameters 4.7.2 Motor Auto-tuning To obtain the motor parameters, the AC drive can perform dynamic auto-tuning or static auto-tuning. For the asynchronous motor that cannot be disconnected from the load, you can input the motor parameters of the same model that was successfully auto-tuned before. Auto-tuning No-load dynamic auto-tuning With-load dynamic auto-tuning Static auto-tuning Manual input Application Result It is applied to applications where the motor (synchronous motor or asynchronous motor) can be disconnected from the load. It is applied to applications where the motor asynchronous cannot be disconnected from the load. It is applied to applications where the motor (asynchronous motor only) cannot be disconnected from the load and dynamic auto-tuning is not allowed. It is applied to applications where the motor (asynchronous motor only) cannot be disconnected from the load. Input the motor parameters of the same model that was successfully autotuned before into function codes P1-00 to P1-10. Best OK Poor OK The following motor auto-tuning description takes motor 1 as an example. The process of motor auto-tuning is as follows: 1) If the motor can be disconnected from the load, disconnect the motor from the load mechanically after power-off so that the motor can run without load. 2) After power-on, set P0-01 (Command source selection) to 0 (Operation panel control). 3) Input the motor nameplate parameters (such as P1-00 to P1-05) correctly and input the following parameters based on the actually selected motor. P1-00: Motor type selection P1-01: Rated motor power P1-02: Rated motor voltage P1-03: Rated motor current P1-04: Rated motor frequency P1-05: Rated motor rotational speed For asynchronous motor, set P1-11 (Auto-tuning selection) to 2 (Asynchronous motor complete auto-tuning). Press Then press on the operation panel. The operation panel displays: on the operation panel. The AC drive will drive the motor to accelerate/ decelerate and run in the forward/reverse direction, and the RUN indicator is ON. The autotuning lasts approximately 2 minutes. When the preceding display information www.ssinverter.info SSI700 User Manual Operation, Display and Application Example disappears and the operation panel returns to the normal parameter display status, it indicates that the auto-tuning is complete. The AC drive will automatically calculate the following motor parameters: P1-06: Stator resistance (asynchronous motor) P1-07: Rotor resistance (asynchronous motor) P1-08: Leakage inductive reactance (asynchronous motor) P1-09: Mutual inductive reactance (asynchronous motor) P1-10: No-load current (asynchronous motor) If the motor cannot be disconnected from the load, set P1-11 (Auto-tuning selection) to 1 (Asynchronous motor static tuning) and then press motor auto-tuning starts. on the operation panel. The 4.7.3 Setting and Switchover of Multiple Groups of Motor Parameters You can select the current effective motor parameter group by means of function code P0-26 or DI terminals with functions 41 and 42. When the DI terminals with functions 41 and 42 become ON, they are privileged and the setting of P0-26 becomes invalid. 4.8 Use of DI Terminals The control board provides five DI terminals DI1 to DI5. The internal hardware of DI terminals are configured with 24 VDC power supply for detection. You can input a signal to a DI terminal of the AC drive only by shorting the DI terminal and COM. By default, P4-38 = 0000 and P4-39 = 0000. When a DI terminal is shorted to COM, it isactive (logic 1). When a DI terminal is not shorted to COM, it is inactive (logic 0). You can change the DI terminal active mode. That is, a DI terminal is inactive (logic 0) when being shorted with COM, and active (logic 1) when being not shorted to COM. In this case, it is necessary to change the corresponding bit in P4-38 and P4-39 (these two parameters respectively specifying the active mode setting of DI1 to DI5 and DI16 to DI10) to 1. The AC drive also provides P4-10 (DI filter time) for the DI signal to improve the antiinterference level. For DI1 to DI3, the AC drive provides the DI signal delay function, convenient for some applications requiring delay. Figure 4-29 DI delay setting The preceding 5 DI terminals can be defined in function codes P4-00 to P4-04. Each DI can be allocated with their respective function from the 50 functions. For details, see descriptions of P4-00 to P4-04. The hardware design allows only DI5 to receive high-speed pulse signal. If high-speed pulse count is required, use DI5. www.ssinverter.info SSI700 User Manual Operation, Display and Application Example 4.9 Use of DO Terminals The control board provides three DO terminals, namely FM, DO1 and TA/TB/TC. FM and DO1 are transistor outputs and can drive 24 VDC low-voltage circuit; TA/TB/TC is relay output, and can drive 250 VAC control circuit. You can define the function of the DO terminals by setting P5-01 and P5-04 to indicate the running state and alarm information of the AC drive. There are a total of 40 functions. For details, see the descriptions of group P5. Terminal FM-CME TA-TB-TC DO1-CME Corresponding Function Code P5-06 when P5-00 = 0 P5-01 when P5-00 = 1 P5-02 P5-04 Output Feature Description Transistor, able to output high-speed pulses 10 Hz to 100 kHz; drive capacity: 24 VDC, 50 Ma Transistor; drive capacity: 24 VDC, 50 Ma Relay; drive capacity: 250 VAC, 3 A Transistor; drive capacity: 24 VDC, 50 mA When P5-00 = 0, the FM terminal is high-speed pulse output. The frequency of output pulses indicates the value of the internal running parameters. The greater the value is, the higher the output pulse frequency is. The 100% value corresponds to 100 kHz. The property of the indicated internal parameter is defined by P5-06. 4.10 Use of AI Terminals The AC drive supports a total of three AI terminals, among which AI1 and AI2 are provided on the control board. Terminal AI1-GND AI2-GND Input Signal Characteristic It receives the signal of 0–10 VDC. If J8 is connected to the position with "V" mark, it receives the signal of 0–10 VDC. If J8 is connected to the position with "I" mark, it receives the signal of 4–20 mA. As external voltage/current signal, AI is used for frequency source setting, torque setting, voltage setting at V/F separation, and PID setting or feedback. The corresponding relationship of the voltage or current and actual setting or feedback is defined by P4-13 to P4-27. Figure 4-30 Defining corresponding relationship of the voltage or current and actual setting or feedback The sampling of AI terminals can be queried in D0-09 to D0-11. The calculation value is for internal subsequent calculation and cannot be directly read by the user. 4.11 Use of AO Terminals The AC drive supports a total of two AO terminals, among which AO1 is provided by the control board. www.ssinverter.info SSI700 User Manual Terminal AI1-GND AI2-GND Operation, Display and Application Example Input Signal Characteristic It receives the signal of 0–10 VDC. If J8 is connected to the position with "V" mark, it receives the signal of 0–10 VDC. If J8 is connected to the position with "I" mark, it receives the signal of 4–20 mA. AO1 can be used to indicate the internal running parameters in the analog mode. The property of indicated parameters can be defined by P5-07 and P5-08. The designated running parameters can be rectified before output. The rectification feature is Y = kX + b, among which "X" indicates the running parameters to be output, and "k" and "b" of AO1 can be set by P5-10 and P5-11. Figure 4-31 Setting of "k" and "b" of AO1 4.12 Use of Serial Communication When communication mode RS485 on the SSI700 series AC drive, and set P0-28 correctly according to the used communication protocol type. For the configuration of hardware communication parameters for the communication port, see group 13. Set the communication rate and data format to consistent with those of the host computer, which is the precondition of normal communication. The SSI700 serial port itself supports the Modbus RTU slave communication protocol. You can query or modify the AC drive's function codes, query various running state parameters, and send running command and running frequency to the AC drive from the host computer through the serial port. Figure 4-32 Communication control mode of the AC drive The SSI700 arranges the function codes, running state parameters and running commands in the "register parameter address" mode. The host computer can define the protocol of communication data interaction. 4.13 Password Setting The AC drive provides the user password protection function. When 16-00 is set to a nonzero value, the value is the user password. The password takes effect after you after exit the function code editing state. When you press again, "------" will be displayed, and you must enter the correct user password to enter the menu. To cancel the password protection function, enter with password and set 16-00 to 0. www.ssinverter.info SSI700 User Manual Operation, Display and Application Example 4.14 Parameter Saving and Default Setting Restoring After a function code is modified on the operation panel, the modification will be saved in the register of the AC drive and remain effective at next power-on. The AC drive supports backup and restoration of parameter setting, which is convenient for commissioning. The AC drive also provides the retentive function on alarm information and accumulative running time. You can restore the backup values or default settings of the function codes of the AC drive or clear the running data through 16-01. For details, see the description of 16-01. Figure 4-35 Parameter saving and default parameter restoring www.ssinverter.info Function Code Table SSI700 User Manual Function Code Chapter 5 Function Code Table If 16-00 is set to a non-zero number, parameter protection is enabled. You must enter the correct user password to enter the menu. To cancel the password protection function, enter with password and set 16-00 to 0. Group P are standard function parameters. The symbols in the function code table are described as follows: "☆": The parameter can be modified when the AC drive is in either stop or running state. "★": The parameter cannot be modified when the AC drive is in the running state. "●": The parameter is the actually measured value and cannot be modified. "*": The parameter is factory parameter and can be set only by the manufacturer. 5 Standard Function Parameters Function Code P0-00 Parameter Name Setting Range Group P0: Standard Function Parameters 0:Sensorless flux vector control (SFVC) Motor control mode 1: Voltage/Frequency (V/F) control Default Property 0 ★ 0 ☆ 1 * 10 ★ 1 ★ 0 ☆ 100% ☆ 0:Operation panel control (LED off) P0-01 Command source selection Run/Stop P0-02 G/P(Motor) type display P0-03 Main frequency source A selection P0-04 P0-05 P0-06 Auxiliary frequency source B selection Range of auxiliary frequency B for A and B operation Range of auxiliary frequency B for A and B operation 1: Terminal control (LED on) 2: Communication control (LED blinking) 1:G type(constant torque load) 0: Digital setting Preset P0-08, UP/DOWN Can be modified. (non-retentive at power failure) 1: Digital setting Preset P0-08, UP/DOWN Can be modified. (retentive at power failure) 2: AI1 3: AI2 4: Reserved 5: Pulse setting (DI5) 6: Multi-reference 7: Simple PLC 8: PID 9: Communication setting 10: Potentiometer key pad The same as P0-03 (Main frequency source A selection) 0:Relative to maximum frequency 1: Relative to main frequency A 0%–150% www.ssinverter.info SSI700 User Manual Function Code P0-07 Parameter Name Preset frequency P0-09 Rotation direction P0-10 Maximum frequency P0-11 Source of frequency upper limit P0-12 Frequency upper limit P0-13 Frequency upper limit offset P0-14 Frequency lower limit P0-16 Carrier frequency Carrier frequency adjustment with temperature P0-17 Acceleration time 1 P0-18 Deceleration time 1 P0-19 P0-20 P0-21 P0-22 Setting Range Group P0: Standard Function Parameters Unit's digit (Frequency source selection) 0: Main frequency source A 1: A and B operation (operation relationship determined by ten's digit) 2: Switchover between A and B 3: Switchover between A and "A Frequency source and B operation" selection 4: Switchover between B and "A and B operation" P0-08 P0-15 Function Code Acceleration/Deceleration time unit reserved Frequency offset of auxiliary frequency source for A and B operation Frequency reference resolution Ten's digit (A and B operation relationship) 0: A+B 1: A-B 2: Maximum 3: Minimum 0.00 to maximum frequency (valid when frequency source is digital setting) 0: Same direction 1: Reverse direction Vector : 50.00–320.00 Hz V/F : 50.00–3200.00 Hz 0: Set by P0-12 1: AI1 2: AI2 3: Reserved 4: Pulse setting (DI5) 5: Communication setting Frequency lower limit (P0-14) to maximum frequency (P0-10) 0.00 Hz to maximum frequency (P0-10) 0.00 Hz to frequency upper limit (P0-12) 0.5–16.0 kHz 0: No 1: Yes 0.00–650.00s (P0-19 = 2) 0.0–6500.0s (P0-19 = 1) 0–65000s (P0-19 = 0) 0.00–650.00s (P0-19 = 2) 0.0–6500.0s (P0-19 = 1) 0–65000s (P0-19 = 0) 0:1s 1: 0.1s 2: 0.01s -0.00 Hz to maximum frequency (P0-10) 1: 0.1 Hz 2: 0.01 Hz Default Property 00 ☆ 50.00 Hz ☆ 0 ☆ 50.00 Hz ★ 0 ★ 50.00 Hz 0.00 Hz 0.00 Hz ☆ ☆ ☆ Model dependent ☆ 1 ☆ Model dependent ☆ Model dependent ☆ 1 ★ 0 - 0.00 Hz ☆ 2 ★ www.ssinverter.info SSI700 User Manual Function Code P0-23 P0-24 Function Code P1-00 P1-01 P1-02 P1-03 P1-04 P1-05 P1-06 P1-07 P1-08 P1-09 P1-10 P1-11 Function Code Function Code Parameter Name Setting Range Group P0: Standard Function Parameters Retentive of digital 0: Not retentive setting frequency upon 1: Retentive power failure 0: Maximum frequency (P0-10) Acceleration/Deceleration 1: Set frequency time base frequency 2: 100 Hz Parameter Name Setting Range Group P1: Motor 1 Parameters 0: Common asynchronous motor Motor type selection 1: Variable frequency motor 0.1–4.0 kW Rated motor power Rated motor voltage Rated motor current Rated motor frequency Rated motor rotational speed Stator resistance (asynchronous motor) Rotor resistance (asynchronous motor) Leakage inductive reactance (motor) Mutual inductive reactance ( motor) No-load current (asynchronous motor) Auto-tuning selection Parameter Name 1–500 V 0.01–655.35 A (AC drive power ≤55 kW) 0.01 Hz to maximum frequency 1–65535 RPM 0.001–65.535 Ω (AC drive power ≤ 55 kW) 0.001–65.535 Ω (AC drive power ≤ 55 kW) 0.01–655.35 mH (AC drive power ≤ 55 kW) 0.1–6553.5 mH (AC drive power ≤ 55 kW) 0.01 to P1-03 (AC drive power ≤ 55 kW) 0: No auto-tuning 1: Asynchronous motor static auto-tuning 2: Asynchronous motor complete auto-tuning Setting Range Default Property 0 ☆ 0 ★ Default Property 0 ★ Model Dependent Model Dependent ★ ★ Model Dependent ★ Model Dependent ★ Model Dependent ★ Model dependent ★ Model Dependent ★ Model Dependent ★ Model Dependent ★ Model Dependent ★ 0 ★ Default Property Group P2: Vector Control Parameters P2-00 P2-01 P2-02 P2-03 Speed loop proportional gain 1 Speed loop integral time 1 Switchover frequency 1 Speed loop proportional gain 2 P2-04 Speed loop integral time 2 P2-05 Switchover frequency 2 P2-06 P2-07 P2-08 P2-09 Time constant of speed loop filter Vector control slip gain Vector control overexcitation gain Digital setting of torque upper limit in speed control mode 0–100 0.01–10.00s 0.00 to P2-05 0–100 30 ☆ 0.50s 5.00HZ ☆ ☆ 20 ☆ 1.00s ☆ 10.0HZ ☆ 0.000–0.100s 0.000s ☆ 50%–200% 150% ☆ 64 ☆ 150% ☆ 0.01–10.00s P2-02 to maximum output frequency 0–200 0.0%–200.0% www.ssinverter.info SSI700 User Manual Function Code P2-10 P2-13 P2-14 P2-15 P2-16 P2-17 Function Code P3-00 P3-01 P3-02 P3-03 P3-04 P3-05 P3-06 P3-07 P3-08 P3-09 P3-10 P3-11 Parameter Name Function Code Setting Range Group P2: Vector Control Parameters 0: Function code P2-09 setting 1: AI1 2: AI2 3: reserved Torque upper limit 4: Pulse setting (DI5) source in speed control 5: Communication setting mode 6: MIN(AI1,AI2) 7: MAX(AI1,AI2) 1~7 ful range corresponding to P2-09 Excitation adjustment 0~60000 proportional gain Excitation adjustment 0~60000 integral gain Torque adjustment 0~60000 proportional gain Torque adjustment 0~60000 integral gain Unit's digit: integral separation Speed loop integral 0: Disabled property 1: Enabled Parameter Name Setting Range Group P3: V/F Control Parameters Cut-off frequency of 0.00 Hz to maximum output torque boost frequency 0.0% (fixed torque boost) 0.1%– Torque boost 30.0% 0: Linear V/F 1: Multi-point V/F 2: Square V/F V/F curve setting 3: 1.2-power V/F 4: 1.4-power V/F 6: 1.6-power V/F 8: 1.8-power V/F Multi-point V/F 0.00 Hz to P3-05 frequency 1(F1) Multi-point V/F voltage 1 0.0%–100.0% (V1) Multi-point V/F P3-03 to P3-07 frequency 2(F2) Multi-point V/F voltage 2 0.0%–100.0% (V2) Multi-point V/F P3-05 to rated motor frequency frequency 3 (F3) (P1-04) Multi-point V/F voltage 3 0.0%–100.0% (V3) V/F slip compensation 0%–200.0% gain V/F over-excitation gain 0–200 V/F oscillation 0–100 suppression gain Default Property 0 ☆ 2000 ☆ 1300 ☆ 2000 ☆ 1300 ☆ 0 ☆ Default Property 50.0HZ ★ Model dependent ☆ 0 ★ 0.00 Hz ★ 0.0% ★ 0.00 Hz ★ 0.0% ★ 0.00 Hz ★ 0.0% ★ 0.0% ☆ 64 ☆ Model dependent ☆ www.ssinverter.info SSI700 User Manual Function Code Parameter Name P4-00 P4-01 P4-02 P4-03 P4-04 P4-05 P4-06 P4-07 DI1 function selection DI2 function selection DI3 function selection DI4 function selection DI5 function selection Reserved Reserved Reserved P4-08 Reserved Function Code Setting Range Group P4: Input Terminals 0: No function 1: Forward RUN (FWD) 2: Reverse RUN (REV) 3: Three-line control 4: Forward JOG (FJOG) 5: Reverse JOG (RJOG) 6: Terminal UP 7: Terminal DOWN 8: Coast to stop 9: Fault reset (RESET) 10: RUN pause 11: Normally open (NO) input of external fault 12: Multi-reference terminal 1 13: Multi-reference terminal 2 14: Multi-reference terminal 3 15: Multi-reference terminal 4 16: Terminal 1 for acceleration/ deceleration time selection 1 17: Terminal 2 for acceleration/ deceleration time selection 2 18:Frequency source switchover 19: UP and DOWN setting clear (terminal, operation panel) 20: Command source switchover terminal 1 21:Acceleration/Deceleration prohibited 22: PID pause 23: PLC status reset 24: Swing Frequency pause 25: Counter input 26: Counter reset 27: Length count input 28: Length reset 29: Torque control prohibited 30: Pulse input (enabled only for DI5) 31:Reserved 32: Immediate DC braking 33: Normally closed (NC) input of external fault 34: Frequency modification forbidden 35: Reverse PID action direction 36: External STOP terminal 1 37: Command source switchover terminal 2 38: PID integral pause 39: Switchover between main frequency source A and preset frequency 40: Switchover between auxiliary frequency source B and preset frequency 41: reserved 42: reserved 43: PID parameter switchover 44: reserved Default Property 1 2 9 12 13 - ★ ★ ★ ★ ★ - - - www.ssinverter.info SSI700 User Manual Function Code Function Code Parameter Name Setting Range Group P4: Input Terminals 45: reserved 46: Speed control/Torque control switchover 47: Emergency stop 48: External STOP terminal 2 49: Deceleration DC braking 50:Clear the current running time 51~59: Reserved 0.000–1.000s 0: Two-line mode 1 1: Two-line mode 2 2: Three-line mode 1 3: Three-line mode 2 P4-09 Reserved P4-10 DI filter time P4-11 Terminal command mode P4-12 Terminal UP/DOWNrate 0.01–65.535 Hz/s P4-13 0.00 V to P4-15 P4-22 AI1curve minimum input Corresponding setting of AI curve 1 minimum input AI1curve maximum input Corresponding setting of AI1curve maximum input AI1 filter time AI2 curve minimum input Corresponding setting of AI2 curve minimum input AI2 curve maximum input Corresponding setting of AI2 curve maximum input AI2 filter time P4-28 Pulse minimum input 0.00 kHz to P4-30 P4-29 Corresponding setting of pulse minimum input -100.00%–100.0% P4-14 P4-15 P4-16 P4-17 P4-18 P4-19 P4-20 P4-21 P4-30 Pulse maximum input P4-32 Corresponding setting of pulse maximum input Pulse filter time P4-33 AI curve selection P4-31 Default Property - - 0.010s ☆ 1 ★ 1.0 Hz/s 0.00 V -100.00%+100.0% ☆ ☆ 0.0% ☆ 10.00V ☆ -100.00%+100.0% 100.0 % ☆ 0.00–10.00s 0.10s ☆ 0.00 V to P4-20 0.00 V ☆ 0.0% ☆ 10.00V ☆ 100.0 % ☆ P4-13 to 10.00 V -100.00%+100.0% P4-18 to 10.00 V -100.00%+100.0% 0.00–10.00s P4-28 to 50.00 kHz -100.00%+100.0% 0.00–10.00s Unit's digit (AI1 curve selection) Curve 1 (2 points, see P4-13 to P4-16) Curve 2 (2 points, see P4-18 to P4-21) Curve 3 (2 points, see P4-23 to P4-26) Curve 4 Reserved Curve 5 Reserve Ten's digit (AI2 curve selection) Curve1 to curve 5 (same as AI1) 0.10s 0.00 kHz ☆ 0.0% ☆ 50.00 kHz 100.0 % 0.10s 321 ☆ ☆ ☆ ☆ ☆ www.ssinverter.info SSI700 User Manual Function Code P4-34 P4-35 P4-36 P4-38 Function Code P5-00 P5-01 P5-02 P5-03 P5-04 Parameter Name Function Code Setting Range Group P4: Input Terminals Unit's digit (Setting for AI1 less than minimum input) 0: Minimum value Setting for AI less than 1: 0.0% minimum input Ten's digit (Setting for AI2 less than minimum input) 0, 1 (same as AI1) 0.0–3600.0s DI1 delay time 0.0–3600.0s DI2 delay time Unit's digit (DI1 valid mode) 0: High level valid 1: Low level valid Ten's digit (DI2 valid mode) 0, 1 (same as DI1) Hundred's digit (DI3 valid mode) DI valid mode selection1 0, 1 (same as DI1) Thousand's digit(DI4 valid mode) 0, 1 (same as DI1) Ten thousand's digit(DI5 valid mode) 0, 1 (same as DI1) Parameter Name Setting Range Group P5: Output Terminals FM terminal output 0: Pulse output (FMP) mode 1: Switch signal output (FMR) 0: No output FMR function 1: AC drive running (opencollector 2: Fault output (stop) output terminal) 3: Frequency-level detection Relay function (T/A-T/BBRAKE control 1 output T/C) 4: Frequency reached Reserved 5: Zero-speed running (no output at stop) 6: Motor overload pre-warning 7: AC drive overload pre-warning 8: Set count value reached 9: Designated count value reached 10: Length reached 11: PLC cycle complete 12: Accumulative running time reached 13: Frequency limited DO1 function selection 14: Torque limited (open-collector output 15: Ready for RUN terminal) 16: AI1 larger than AI2(AI1>AI2) 17: Frequency upper limit reached 18: Frequency lower limit reached (no output at stop) 19: Undervoltage state output 20: Communication setting 21: Complete orientation 22: Location close to 23: Zero-speed running 2 (having output at stop) Default Property 000 ☆ 0.0s 0.0s ★ ★ 00000 ★ Default Property 0 ☆ 0 ☆ 2 ☆ - - 4 ☆ www.ssinverter.info SSI700 User Manual Function Code P5-05 P5-06 P5-07 P5-08 P5-09 P5-10 P5-11 P5-17 P5-18 P5-20 P5-22 Parameter Name Function Code Setting Range Group P5: Output Terminals 24: Accumulative power-on time reached 25: Frequency level detection BRAKE control 2 output 26: Frequency 1 reached 27: Frequency 2 reached 28: Current 1 reached 29: Current 2 reached 30: Timing reached 31: AI1 input limit exceeded 32: Load becoming 0 (Drop in) Reserved 33: Reverse running 34: Zero current state 35: Module temperature reached 36: Software current limit exceeded 37: Frequency lower limit reached (having output at stop) 38: Alarm output 39: Motor overheat warning 40: Current running time reached 0: Running frequency 1: Set frequency 2: Output current FMP function selection 3: Output torque (absolute value) 4: Output power 5: Output voltage 6: Pulse input 7: AI1 AO1 function selection 8: AI2 9: Reserved 10: Length 11: Count value 12: Communication setting 13: Motor rotational speed Reserved 14: Output current 15: Output voltage 16: Reserved Maximum FMP output 0.01–100.00 kHz frequency AO1 offset coefficient -100.0%–100.0% -10.00–10.00 AO1 gain 0.0–3600.0s FMR output delay time Relay1 output delay 0.0–3600.0s time 0.0–3600.0s DO1 output delay time Unit's digit (FMR valid mode) 0: Positive logic 1: Negative logic DO valid mode selection Ten's digit (Relay valid mode) 0, 1 (same as FMR) Thousand's digit (DO1 valid mode) 0, 1 (same as FMR) Default Property - - 0 ☆ 0 ☆ - - 50.00 kHz 0.0% 1.00 0.0s ☆ ☆ ☆ ☆ 0.0s ☆ 0.0s ☆ 00000 ☆ www.ssinverter.info SSI700 User Manual Function Code Function Code P6-00 Start mode P6-01 Startup frequency P6-02 Rotational speed tracking mode P6-03 P6-04 P6-05 P6-06 P6-07 P6-08 P6-09 P6-10 P6-11 P6-12 P6-13 P6-14 P6-15 Function Code Default Property 0 ☆ 0.00Hz ☆ 0 ★ 20 ☆ 0.0–100.0s 0.0s ★ 0%–100% 0% ★ 0.0–100.0s 0.0s ★ 0 ★ 0.0% to (100.0% – P6-09) 30.0% ★ 0.0% to (100.0% – P6-08) 30.0% ★ 0 ☆ 0.00 Hz to maximum frequency 0.00 Hz ☆ 0.0–100.0s 0.0s ☆ 0%–100% 0.0–100.0s 0%–100% 0% 0.0s 100% ☆ ☆ ☆ Default Property Parameter Name Setting Range Group P6: Start/Stop Control 0: Direct start 1: Rotational speed tracking restart 2: Pre-excited start (asynchronous motor) 0.00–10.00 Hz 0: From frequency at stop 1: From zero speed 2: From maximum frequency Rotational speed tracking speed Startup frequency holdingtime Startup DC braking current/Pre-excited current Startup DC braking time/Pre-excited time Acceleration/Deceleratio n mode Time proportion of Scurve start segment Time proportion of Scurve end segment 1–100 0: Linear acceleration/ deceleration 1: S-curve acceleration/ deceleration A 2: S-curve acceleration/ deceleration B 0: Decelerate to stop 1: Coast to stop Stop mode Initial frequency of stop DC braking Waiting time of stop DC braking Stop DC braking current Stop DC braking time Brake use ratio Parameter Name Setting Range Group P7: Operation Panel and Display P7-00 Reserved P7-01 APP Key function selection P7-02 STOP/RESET key function 0 0:APP key disabled 1: Switchover between operation panel control and remote command control (terminal or communication) 2: Switchover between forward rotation and reverse rotation 3: Forward JOG 4: Reverse JOG 0: STOP/RESET key enabled only in operation panel control 1: STOP/RESET key enabled in any operation mode 0 ★ 1 ☆ www.ssinverter.info SSI700 User Manual Function Code P7-03 P7-04 P7-05 Parameter Name Function Code Setting Range Default Group P7: Operation Panel and Display 0000–FFFF Bit00: Running frequency 1 (Hz) Bit01: Set frequency (Hz) Bit02: Bus voltage (V) Bit03: Output voltage (V) Bit04: Output current (A) Bit05: Output power (kW) Bit06: Output torque (%) LED display running Bit07: DI input status parameters 1 Bit08: DO output status Bit09: AI1 voltage (V) Bit10: AI2 voltage (V) Bit11: Reserved Bit12: Count value Bit13: Length value Bit14: Load speed display Bit15: PID setting 0000–FFFF Bit00: PID feedback Bit01: PLC stage Bit02: Pulse setting frequency (kHz) Bit03: Running frequency 2 (Hz) Bit04: Remaining running time Bit05: AI1 voltage before correction (V) Bit06: AI2 voltage before correction (V) Bit07: Reserved LED display running Bit08: Linear speed Bit09: Current power-on time parameters 2 (Hour) Bit10: Current running time (Min) Bit11: Pulse setting frequency (Hz) Bit12: Communication setting value Bit13: Encoder feedback speed (Hz) Bit14: Main frequency A display (Hz) Bit15: Auxiliary frequency B display (Hz) 0000–FFFF Bit00: Set frequency (Hz) Bit01: Bus voltage (V) Bit02: DI input status Bit03: DO output status Bit04: AI1 voltage (V) Bit05: AI2 voltage (V) LED display stop Bit06: Reserved parameters Bit07: Count value Bit08: Length value Bit09: PLC stage Bit10: Load speed Bit11: PID setting Bit12: Pulse setting frequency (kHz) Property 1F 0 ☆ 33 ☆ www.ssinverter.info SSI700 User Manual Function Code P7-06 P7-07 P7-08 P7-09 P7-10 P7-11 P7-12 P7-13 P7-14 Function Code Function Code Parameter Name Setting Range Group P7: Operation Panel and Display Load speed display 0.0001–6.5000 coefficient Heatsink temperature of 0.0–100.0°C inverter module Temporary software -version Accumulative running 0–65535 h time Product number -Software version -0: 0 decimal place Number of decimal 1: 1 decimal place places for load speed 2: 2 decimal places display 3: 3 decimal places Accumulative power-on 0–65535 h time Accumulative power 0–65535 kWh consumption Parameter Name Setting Range Default Property 1.0000 ☆ -- ● -- ● -- ● --- ● ● 1 ☆ 0h ● -- ● Default Property Group P8: Auxiliary Functions P8-00 JOG running frequency 0.00 Hz to maximum frequency P8-01 P8-02 JOG acceleration time JOG deceleration time 0.0–6500.0s 0.0–6500.0s P8-03 Acceleration time 2 0.0–6500.0s P8-04 Deceleration time 2 0.0–6500.0s P8-05 Acceleration time 3 dependent Model dependent Model 0.0–6500.0s P8-06 Deceleration time 3 0.0–6500.0s P8-07 Acceleration time 4 0.0–6500.0s 2.00 Hz 20.0s 20.0s Model dependent Model dependent Model dependent Model ☆ ☆ ☆ ☆ ☆ ☆ ☆ ☆ P8-08 Deceleration time 4 0.0–6500.0s P8-09 Jump frequency 1 0.00 Hz to maximum frequency 0.00Hz ☆ P8-10 Jump frequency 2 Frequency jump amplitude Forward/Reverse rotation dead-zone time 0.00 Hz to maximum frequency 0.00Hz ☆ 0.00 Hz to maximum frequency 0.00Hz ☆ 0.0s ☆ 0 ☆ 0 ☆ 0.00Hz ☆ threshold 0–65000 0h ☆ threshold 0–65000 0h ☆ 0 ☆ 50.00 Hz ☆ P8-11 P8-12 P8-13 P8-14 P8-15 P8-16 P8-17 Reverse control Running mode when set frequency lower than frequency lower limit Droop control Accumulative power-on time Accumulative running time P8-18 Startup protection P8-19 Frequency detection value (BRAKE control 1) dependent 0.0–3000.0s 0: Enabled 1: Disabled 0: Run at frequency lower limit 1: Stop 2: Run at zero speed 0.00–10.00 Hz 0: No 1: Yes 0.00 Hz to maximum frequency ☆ www.ssinverter.info SSI700 User Manual Function Code Function Code Parameter Name Setting Range Default Property 5.0% ☆ 0.0% ☆ 0 ☆ - - Group P8: Auxiliary Functions P8-20 P8-21 P8-22 P8-23 P8-24 P8-28 P8-29 P8-30 P8-31 P8-32 P8-33 P8-34 P8-35 Frequency detection hysteresis (BRAKE control hysteresis 1) Detection range of frequency reached Jump frequency during acceleration/deceleration reserved reserved Frequency detection value (BRAKE control 2) Frequency detection hysteresis (BRAKE control hysteresis 2) Any frequency reaching detection value 1 Any frequency reaching detection amplitude 1 Any frequency reaching detection value 2 Any frequency reaching detection amplitude 2 Zero current detection level Zero current detection delay time 0.0%–100.0% (BRAKE control hysteresis 1) 0.00–100% (maximum frequency) 0: Disabled 1: Enabled - - 0.00 Hz to maximum frequency 50.00 Hz ☆ 0.0%–100.0% (BRAKE control hysteresis 2) 5.0% ☆ 0.00 Hz to maximum frequency 50.00 Hz ☆ 0.0%–100.0% (maximum frequency) 0.0% ☆ 0.00 Hz to maximum frequency 50.00 Hz ☆ 0.0% ☆ 5.0% ☆ 0.00–600.00s 0.10s ☆ 0.0%–100.0% (maximum frequency) 0.0%–300.0% (rated motor current) P8-36 Output overcurrent threshold 0.0% (no detection) 0.1%–300.0% (rated motor current) 200.0 % ☆ P8-37 Output overcurrent detectiondelay time 0.00–600.00s 0.00s ☆ P8-38 Any current reaching 1 100.0 % ☆ P8-39 Any current reaching 1 amplitude 0.0% ☆ P8-40 Any current reaching 2 100.0 % ☆ P8-41 Any current reaching 2 amplitude 0.0% ☆ P8-42 Timing function 0 ☆ P8-43 Timing duration source 0 ☆ P8-44 Timing duration AI1 input voltage lower limit AI1 input voltage upper limit Module temperature threshold 0.0%–300.0% (rated motor current) 0.0%–300.0% (rated motor current) 0.0%–300.0% (rated motor current) 0.0%–300.0% (rated motor current) 0: Disabled 1: Enabled 0: P8-44 1: AI1 2: AI2 3: Reserved (100%of analog input corresponds to the value of P8-44) 0.0–6500.0 min 0.0 min ☆ 0.00 V to P8-46 3.10V ☆ P8-45 to 10.00 V 6.80 V ☆ 75°C ☆ 0 ☆ P8-45 P8-46 P8-47 P8-48 Cooling fan control 0–100°C 0: Fan working during running 1: Fan working continuously www.ssinverter.info SSI700 User Manual Function Code P8-49 P8-50 P8-51 P8-52 P8-53 Function Code P9-00 P9-01 P9-02 P9-03 P9-04 P9-05 P9-06 P9-07 P9-09 P9-10 P9-11 P9-12 P9-13 P9-14 Parameter Name Function Code Setting Range Group P8: Auxiliary Functions Dormant frequency (P8-51) to Wakeup frequency maximum frequency (P0-10) Wakeup delay time 0.0–6500.0s Dormant(Sleeping) 0.00 Hz to wakeup frequency frequency (P8-49) Dormant(Sleeping) 0.0–6500.0s delay time Current running time 0.0–6500.0 min reached Parameter Name Setting Range Group 9: Fault and Protection Motor overload 0: Disabled protection selection 1: Enabled Motor overload 0.20–10.00 protection gain Motor overload warning 50%–100% coefficient Overvoltage stall gain 0 (no stall overvoltage)–100 Overvoltage stall 120%–150% protective voltage Overcurrent stall gain 0–100 Overcurrent stall 100%–200% protective current Short-circuit to ground 0: Disabled upon power-on 1: Enabled Fault auto reset times 0–20 DO action during fault 0: Not act auto reset 1: Act Time interval of fault 0.1s–100.0s auto reset Unit's digit: Input phase loss Input phase loss protection protection/ contactor Ten's digit: Contactor energizing energizing protection protection selection 0: Disabled 1: Enabled Output phase loss 0: Disabled protection selection 1: Enabled 0: No fault 1: Module overheat 1(OH1) 2: Overcurrent during acceleration (OCA) 3: Overcurrent during deceleration (OCD) 4: Overcurrent (Normal) at constant speed (OCN) 5: Overvoltage during 1st fault type Acceleration (OUA) 6: Overvoltage during Deceleration (OUD) 7: Overvoltage (Normal) at constant speed (OUN) 8: Buffer resistance overload (UU) 9: Undervoltage (LU) 10: AC drive overload (OL2) Default Property 0.00Hz ☆ 0.0s ☆ 0.00Hz ☆ 0.0s ☆ 0.0 min ☆ Default Property 1 ☆ 1.00 ☆ 80% ☆ 0 ☆ 130% ☆ 20 ☆ 150% ☆ 1 ☆ 0 ☆ 0 ☆ 1.0s ☆ 11 ☆ 1 ☆ - ● www.ssinverter.info SSI700 User Manual Function Code P9-15 P9-16 P9-17 P9-18 P9-19 P9-20 P9-21 P9-22 P9-23 P9-24 P9-25 P9-26 P9-27 P9-28 P9-29 P9-30 P9-31 P9-32 P9-33 P9-34 P9-37 Parameter Name Function Code Setting Range Group 9: Fault and Protection 11: Motor overload (OL1) 2nd fault type 12: EEPROM read-write fault(ED) 13: External equipment fault(EF) 14: Communication fault(CE) 15: Contactor fault(RL) 16: Current detection fault(CC) 17: Motor auto-tuning fault(ER) 18: No fault 19: Accumulative running time Reached(OT) 20: AC drive hardware fault(EH) 21: Short circuit to ground(GF) 3rd (latest) fault type 22: Motor over-speed(OS) 23: Motor overheat(OH2) 24: PID feedback lost during Running(PD) 25: Accumulative power-on time Reached(UT) 26: Off Load(LL) 27: Too large speed deviation (DEV) 28: Power output phase loss(LF) 29: Initial position fault 30: Power output phase loss Frequency upon 3rd fault Current upon 3rd fault Bus voltage upon 3rd fault DI status upon 3rd fault Output terminal status upon 3rd fault AC drive status upon 3rd fault Power-on time upon 3rd fault Running time upon 3rd fault reserved reserved Frequency upon 2nd fault Current upon 2nd fault Bus voltage upon 2nd fault DI status upon 2nd fault Output terminal status upon 2nd fault AC drive status upon 2rd fault Power-on time upon 2rd fault Running time upon 2rd fault Frequency upon 2nd fault Default Property - ● - ● - ● - ● - ● - ● - ● - ● - ● - ● - - - ● - ● - ● - ● - ● - ● - ● - ● - ● www.ssinverter.info SSI700 User Manual Function Code P9-38 P9-39 P9-40 P9-41 P9-42 P9-43 P9-44 P9-47 P9-48 P9-49 Parameter Name Function Code Setting Range Group 9: Fault and Protection Current upon 1nd fault Bus voltage upon 1nd fault DI status upon 1nd fault Output terminal status upon 1nd fault AC drive status upon 1rd fault Power-on time upon 1rd fault Running time upon 1rd fault Unit's digit (Motor overload, OL1) 0: Coast to stop 1: Stop according to the stop mode 2: Continue to run Ten's digit (Power input phase loss, ) Same as unit's digit Fault protection Hundred's digit (Power output action selection 1 phase loss, LF) Same as unit's digit Thousand's digit (External equipment fault, EF) Same as unit's digit Ten thousand's digit (Communication fault, CE) Same as unit's digit Ten's digit (EEPROM read-write fault, EP) 0: Coast to stop 1: Stop according to the stop Fault protection action Mode selection 2 Ten thousand's digit (Accumulative running time reached) Same as unit's digit in P9-47 Hundred's digit (Accumulative power-on time reached,UT) Same as unit's digit in P9-47 Thousand's digit (Load becoming0) 0: Coast to stop 1: Stop according to the stop Fault protection action mode selection 3 2: Continue to run at 7% of rated motor frequency and resume to the set frequency if the load recovers Ten thousand's digit (PID feedback lost during running, PD) Default Property - ● - ● - ● - ● - ● - ● - ● 00000 ☆ 00000 ☆ 00000 ☆ Same as unit's digit in P9-47 www.ssinverter.info SSI700 User Manual Function Code P9-50 P9-54 P9-55 P9-59 P9-60 P9-61 P9-62 P9-63 P9-64 P9-65 Function Code 10-00 10-01 Parameter Name Function Code Setting Range Group 9: Fault and Protection Unit's digit (Too large speed deviation) Same as unit's digit in P9-47 Ten's digit (Motor over-speed) Same as unit's digit in P9-47 Fault protection action Hundred's digit (Initial position selection 4 fault) Same as unit's digit in P9-47 Thousand's digit (Speed feedback fault) Same as unit's digit in P9-47 Ten thousand's digit: Reserved 0: Current running frequency 1: Set frequency Frequency selection for 2: Frequency upper limit continuing to run upon 3: Frequency lower limit fault 4: Backup frequency upon abnormality Backup frequency upon 0.0%–100.0% (maximum abnormality frequency) Action selection at 0: Invalid instantaneous power 1: Decelerate failure 2: Decelerate to stop Action pause judging voltage at 80.0%–100.0% instantaneous power failure Voltage rally judging time at instantaneous 0.00–100.00s power failure Action judging voltage at instantaneous power failure Protection upon load becoming 0 Detection level of load becoming 0 Detection time of load becoming Parameter Name 60.0%–100.0% (standard bus voltage) 0: Disabled 1: Enabled 0.0%–100.0% (rated motor current) 0 0.0–60.0s Setting Range Group 10: Process Control PID Function 0: 10-01 1: AI1 2: AI2 PID setting source 3: reserved 4: Pulse setting (DI5) 5: Communication setting 6: Multi-reference PID digital setting 0.0%–100.0% Default Property 00000 ☆ 0 ☆ 100.0 % ☆ 0 ☆ 90.0% ☆ 0.50s ☆ 80.0% ☆ 0 ☆ 10.0% ☆ 1.0s ☆ Default Property 0 ☆ 50.0% ☆ www.ssinverter.info SSI700 User Manual Function Code 10-02 10-03 10-04 10-05 10-06 10-07 10-08 10-09 10-10 10-11 10-12 10-13 10-15 10-16 10-17 10-18 10-19 10-20 10-21 10-22 10-23 10-24 10-25 Parameter Name Function Code Default Property 0 ☆ 0 ☆ 1000 ☆ 20.0 2.00s 0.000s 2.00 Hz 0.0% 0.10% 0.00s 0.00s 0.00s 20.0 20.0 0.000s ☆ ☆ ☆ 0 ☆ 0.0% to 10-20 20.0% ☆ 10-19 to 100.0% 80.0% ☆ 0.0%–100.0% 0.0% ☆ 0.00–650.00s 0.00s ☆ 0.00%–100.00% 1.00% ☆ 0.00%–100.00% 1.00% ☆ 00 ☆ Setting Range Group 10: Process Control PID Function 0: AI1 1: AI2 2: reserved 3: AI1 – AI2 PID feedback source 4: Pulse setting (DI5) 5: Communication setting 6: AI1 + AI2 7: MAX (|AI1|, |AI2|) 8: MIN (|AI1|, |AI2|) 0: Forward action PID action direction 1: Reverse action PID setting feedback 0–65535 range Proportional gain Kp1 0.0–100.0 Integral time Ti1 0.01–10.00s Differential time Td1 0.00–10.000 Cut-off frequency of PID 0.00 to maximum frequency reverse rotation PID deviation limit 0.0%–100.0% PID differential limit 0.00%–100.00% PID setting change time 0.00–650.00s PID feedback filter time 0.00–60.00s PID output filter time 0.00–60.00s Proportional gain Kp2 0.0–100.0 Integral time Ti2 0.0–100.0 Differential time Td2 0.000–10.000s PID parameter switchover condition PID parameter switchover deviation 1 PID parameter switchover deviation 2 PID initial value PID initial value holding time Maximum deviation between two PID outputs in forward direction Maximum deviation between two PID outputs in reverse direction PID integral property 0: No switchover 1: Switchover via DI 2: Automatic switchover based on deviation Unit's digit (Integral separated) 0: Invalid 1: Valid Ten's digit (Whether to stop integral operation when the output reaches the limit) 0: Continue integral operation 1: Stop integral operation ☆ ☆ ☆ ☆ ☆ ☆ ☆ ☆ ☆ www.ssinverter.info SSI700 User Manual Function Code 10-26 10-27 10-28 Function Code 11-00 11-01 11-02 11-03 11-04 11-05 11-06 11-07 11-08 11-09 Function Code 12-00 12-01 12-02 12-03 12-04 12-05 12-06 12-07 12-08 12-09 12-10 12-11 12-12 12-13 12-14 12-15 12-16 Parameter Name Function Code Setting Range Group 10: Process Control PID Function 0: No PID operation at stop PID operation at stop 1: PID operation at stop Detection time of 0.0–20.0s PID feedback loss Detection value of 0.0%: Not judging feedback loss PID feedback loss 0.1%–100.0% Parameter Name Setting Range Default Property 0 ☆ 0.0s ☆ 0.0% ☆ Default Property Group 11: Swing Frequency, Fixed Length and Count 0: Relative to the central Swing frequency setting frequency 0 mode 1: Relative to the maximum frequency Swing frequency 0.0%–100.0% 0.0% amplitude Jump frequency 0.0%–50.0% 0.0% amplitude Swing frequency cycle 0.0–3000.0s 10.0s Triangular wave rising 0.0%–100.0% 50.0% timecoefficient Set length 0–65535 m 1000m Actual length 0–65535 m 0m Number of pulses per 0.1–6553.5 100.0 meter Set count value 1–65535 1000 Designated count value 1–65535 1000 Parameter Name Setting Range Group 12: Multi-Reference and Simple PLC Function Reference 0 -100.0%~100.0% Reference 1 -100.0%~100.0% Reference 2 -100.0%~100.0% Reference 3 -100.0%~100.0% Reference 4 -100.0%~100.0% Reference 5 -100.0%~100.0% Reference 6 -100.0%~100.0% Reference 7 -100.0%~100.0% Reference 8 -100.0%~100.0% Reference 9 -100.0%~100.0% Reference 10 -100.0%~100.0% Reference 11 -100.0%~100.0% Reference 12 -100.0%~100.0% Reference 13 -100.0%~100.0% Reference 14 -100.0%~100.0% Reference 15 -100.0%~100.0% 0: Stop after the AC drive runs one cycle Simple PLC running 1: Keep final values after the AC mode drive runs one cycle 2: Repeat after the AC drive runs one cycle ☆ ☆ ☆ ☆ ☆ ☆ ☆ ☆ ☆ ☆ Default Property 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% ☆ ☆ ☆ ☆ ☆ ☆ ☆ ☆ ☆ ☆ ☆ ☆ ☆ ☆ ☆ ☆ 0 ☆ www.ssinverter.info SSI700 User Manual Function Code 12-17 Function Code Parameter Name Setting Range Group 12: Multi-Reference and Simple PLC Function Unit's digit (Retentive upon power failure) 0: No Simple PLC retentive 1: Yes selection Ten's digit (Retentive upon stop) 0: No 1: Yes 12-18 Running time of simple PLC reference 0 0.0–6553.5s (h) 12-19 Acceleration/deceleration time of simple PLC reference 0 0–3 12-20 Running time of simple PLC reference 1 0.0–6553.5s (h) 12-21 Acceleration/deceleration time of simple PLC reference 1 0–3 12-22 Running time of simple PLC reference 2 0.0–6553.5s (h) 12-23 Acceleration/deceleration time of simple PLC reference 2 0–3 12-24 Running time of simple PLC reference 3 0.0–6553.5s (h) 12-25 Acceleration/deceleration time of simple PLC reference 3 0–3 12-26 Running time of simple PLC reference 4 0.0–6553.5s (h) 12-27 Acceleration/deceleration time of simple PLC reference 4 0–3 12-28 Running time of simple PLC reference 5 0.0–6553.5s (h) 12-29 Acceleration/deceleration time of simple PLC reference 5 0–3 12-30 Running time of simple PLC reference 6 0.0–6553.5s (h) 12-31 Acceleration/deceleration time of simple PLC reference 6 0–3 12-32 Running time of simple PLC reference 7 0.0–6553.5s (h) 12-33 Acceleration/deceleration time of simple PLC reference 7 0–3 12-34 Running time of simple PLC reference8 0.0–6553.5s (h) 12-35 Acceleration/deceleration time of simple PLC reference 8 0–3 12-36 Running time of simple PLC reference 9 0.0–6553.5s (h) 12-37 Acceleration/deceleration time of simple PLC reference 9 0–3 12-38 Running time of simple PLC reference 10 0.0–6553.5s (h) Default Property 00 ☆ 0.0s(h) ☆ 0 ☆ 0.0s(h) ☆ 0 ☆ 0.0s(h) ☆ 0 ☆ 0.0s(h) ☆ 0 ☆ 0.0s(h) ☆ 0 ☆ 0.0s(h) ☆ 0 ☆ 0.0s(h) ☆ 0 ☆ 0.0s(h) ☆ 0 ☆ 0.0s(h) ☆ 0 ☆ 0.0s(h) ☆ 0 ☆ 0.0s(h) ☆ www.ssinverter.info SSI700 User Manual Function Code Function Code Parameter Name 12-39 Acceleration/deceleration time of simple PLC reference 10 0–3 12-40 Running time of simple PLC reference 11 0.0–6553.5s (h) 12-41 Acceleration/deceleration time of simple PLC reference 11 0–3 12-42 Running time of simple PLC reference 12 0.0–6553.5s (h) 12-43 Acceleration/deceleration time of simple PLC reference 12 0–3 12-44 Running time of simple PLC reference 13 0.0–6553.5s (h) 12-45 Acceleration/deceleration time of simple PLC reference 13 0–3 12-46 Running time of simple PLC reference 14 0.0–6553.5s (h) 12-47 Acceleration/deceleration time of simple PLC reference 14 0–3 12-48 Running time of simple PLC reference 15 0.0–6553.5s (h) 12-49 Acceleration/deceleration time of simple PLC reference 15 12-50 Default Property 0 ☆ 0.0s(h) ☆ 0 ☆ 0.0s(h) ☆ 0 ☆ 0.0s(h) ☆ 0 ☆ 0.0s(h) ☆ 0 ☆ 0.0s(h) ☆ 0–3 0 ☆ Time unit of simple PLC running 0: s (second)1:h (hour) 0 ☆ Reference 0 source 0: Set by 12-00 1: AI1 2: AI2 3: Reserved 4: Pulse setting 5: PID 6: Set by preset frequency (P008), modified via terminal UP/ DOWN 0 ☆ Default Property 0 ☆ 6005 ☆ 1 ☆ Setting Range Group 12: Multi-Reference and Simple PLC Function 12-51 Function Code 13-00 Parameter Name Data format 13-01 Baud rate 13-02 Local address Setting Range Group 13: Communication Parameters 0: No check,data format <8,N,2> 1: Even parity check, data format <8,E,1> 2: Odd Parity check, data format <8,O,1> 3: No check, data format <8,N,1> Valid for Modbus 0: 300 BPs 1: 600 BPs 2: 1200 BPs 3: 2400 BPs 4: 4800 BPs 5: 9600 BPs 6: 19200 BPs 7: 38400 BPs 8: 57600 BPs 9: 115200 BPs 0: Broadcast address 1~247 www.ssinverter.info SSI700 User Manual Function Code 13-03 13-04 13-05 13-06 Function Code 16-00 16-01 Function Code 17-00 17-01 17-03 17-04 17-05 17-06 17-07 17-08 Parameter Name Function Code Setting Range Group 13: Communication Parameters Response delay 0–20 ms Valid for Modbus 0.0s (invalid) Communication timeout 0.1–60.0s Unit's digit: Modbus protocol Modbus protocol 0: Non-standard Modbus selection protocol 1: Standard Modbus protocol Communication reading 0: 0.01A current resolution 1: 0.1A Parameter Name Setting Range Group 16: Function Code Management User password 0–65535 0: No operation 01: Restore factory settings except motor parameters 02: Clear records Restore default settings 04: Restore user backup parameters 501: Back up current user parameters Parameter Name Setting Range Group 17: Torque Control and Restricting Parameters Speed/Torque control 0: Speed control selection 1: Torque control 0: Digital setting (17-03) 1: AI1 2: AI2 3: Reserved 4: Pulse setting (DI5) Torque setting source in 5: Communication setting torque control 6: MIN (AI1, AI2) 7: MAX (AI1, AI2) Full range of values 1–7 corresponds to the digital setting of 17-03. Torque digital setting in -200.0%–200.0% torque control -reserved Forward maximum 0.00 Hz to maximum frequency frequency in torque (P0-10) control Reverse maximum 0.00 Hz to maximum frequency frequency in torque (P0-10) control Acceleration time in 0.00–65000s torque control Deceleration time in 0.00–65000s torque control Default Property 2 ms ☆ 0.0s ☆ 30 ☆ 0 ☆ Default Property 0 ☆ 0 ★ Default Property 0 ★ 0 ★ 150.0 % 0 ☆ - 50.00 Hz ☆ 50.00 Hz ☆ 0.00s ☆ 0.00s ☆ www.ssinverter.info Description of Function Codes SSI700 User Manual Description of Function Codes Chapter 6 Description of Function Codes Group P0: Basic Parameters Function Code P0-00 • Parameter Name Setting Range Group P0: Standard Function Parameters 0:Sensorless flux vector control (SFVC) Motor control mode 1: Voltage/Frequency (V/F) control Default Property 0 ★ 0: Sensorless flux vector control (SFVC) It indicates open-loop vector control, and is applicable to high-performance control applications such as machine tool, centrifuge, wire drawing machine and injection moulding machine. One AC drive can operate only one motor. • 1: Voltage/Frequency (V/F) control It is applicable to applications with low load requirements or applications where one AC drive operates multiple motors, such as fan and pump. Notes • If vector control is used, motor auto-tuning must be performed because the advantages of vector control can only be utilized after correct motor parameters are obtained. Better performance can be achieved by adjusting speed regulator parameters in group P2 . Function Code Parameter Name Setting Range Default Property 0 ☆ Group P0: Standard Function Parameters 0:Operation panel control (LED off) P0-01 1: Terminal control (LED on) 2: Communication control (LED blinking) Command source selection Run/Stop It is used to determine the input channel of the AC drive control commands, such as run, stop, forward rotation, reverse rotation and jog operation. You can input the commands in the following three channels: • 0: Operation panel control ("LOCAL/REMOT" indicator off) Commands are given by pressing keys and on the operation panel. • 1: Terminal control ("LOCAL/REMOT" indicator on) Commands are given by means of multifunctional input terminals with functions such as FWD, REV, JOGF, and JOGR. • 2: Communication control ("LOCAL/REMOT" indicator blinking) Commands are given from host computer. If this parameter is set to 2, a communication (Modbus RTU) must be installed. Function Code Parameter Name P0-02 G/P(Motor) type display Setting Range Default Property Model * Group P0: Standard Function Parameters 1:G type(constant torque load) dependent www.ssinverter.info SSI700 User Manual Function Code P0-03 Parameter Name Description of Function Codes Setting Range Group P0: Standard Function Parameters 0: Digital setting Preset P0-08, UP/DOWN Can be modified. (non-retentive at power failure) 1: Digital setting Preset P0-08, UP/DOWN Can be modified. (retentive at power failure) 2: AI1 Main frequency source 3: AI2 A selection 4: Reserved 5: Pulse setting (DI5) 6: Multi-reference 7: Simple PLC 8: PID 9: Communication setting 10: Potentiometer key pad Default Property 10 ★ It is used to select the setting channel of the main frequency. You can set the main frequency in the following 10 channels: • 0: Digital setting (non-retentive at power failure) The initial value of the set frequency is the value of P0-08 (Preset frequency). You can change the set frequency by pressing and on the operation panel (or using the UP/DOWN function of input terminals). When the AC drive is powered on again after power failure, the set frequency reverts to the value of P0-08. • 1: Digital setting (retentive at power failure) The initial value of the set frequency is the value of P0-08 (Preset frequency). You can change the set frequency by pressing keys and on the operation panel (or using the UP/DOWN function of input terminals). When the AC drive is powered on again after power failure, the set frequency is the value memorized at the moment of the last power failure. Notes that P0-23 (Retentive of digital setting frequency upon power failure) determines whether the set frequency is memorized or cleared when the AC drive stops. It is related to stop rather than power failure. • 2: AI1 (0–10 V voltage input) • 3: AI2 (0–10 V voltage or 4–20 mA current input, determined by jumper J8) The frequency is set by analog input. The SSI700 control board provides two analog input (AI) terminals (AI1, AI2). The SSI700 provides five curves indicating the mapping relationship between the input voltage of AI1, AI2 and the target frequency, three of which are linear (pointpoint) correspondence and two of which are four-point correspondence curves. You can set the curves by using function codes P4-13 to P4-27 and function codes in select curves for AI1, AI2. When AI is used as the frequency setting source, the corresponding value 100% of the voltage/current input corresponds to the value of P0-10 (Maximum frequency). • 5: Pulse setting (DI5) The frequency is set by DI5 (high-speed pulse). The signal specification of pulse setting is 9–30 V (voltage range) and 0–100 kHz (frequency range). The corresponding value 100% of pulse setting corresponds to the value of P0-10 (Maximum frequency). www.ssinverter.info SSI700 User Manual • Description of Function Codes 6: Multi-reference In multi-reference mode, combinations of different DI terminal states correspond to different set frequencies. The SSI700 supports a maximum of 16 speeds implemented by 16 state combinations of four DI terminals (allocated with functions 12 to 15) in Group 12. The multiple references indicate percentages of the value of P0-10 (Maximum frequency). If a DI terminal is used for the multi-reference function, you need to perform related setting in group P4. • 7: Simple PLC When the simple programmable logic controller (PLC) mode is used as the frequency source, the running frequency of the AC drive can be switched over among the 16 frequency references. You can set the holding time and acceleration/deceleration time of the 16 frequency references. For details, refer to the descriptions of Group 12. • 8: PID The output of PID control is used as the running frequency. PID control is generally used in on-site control, such as constant pressure control and constant tension control. When applying PID as the frequency source, you need to set parameters of PID function in group 10. • 9: Communication setting The frequency is set by means of communication. If the AC drive is a slave in point-point communication and receives data as the frequency source, data transmitted by the master is used as the set frequency. The data format is -100.00% to 100.00%. 100% corresponds to the value of P0-10 (Maximum frequency). In other conditions, data is given by the host computer through the communication address 0x1000. The data format is -100.00% to 100.00%. 100.00% corresponds to the value of P0-10 (Maximum frequency). The SSI700 supports four host computer communication protocols: Modbus. They cannot be used simultaneously. If the communication mode is used. • Function Code P0-04 10: Potentiometer key pad When AI is used as the frequency setting source, the corresponding value 100% of the voltage input corresponds to the value of P0-10 (Maximum frequency). Parameter Name Setting Range Group P0: Standard Function Parameters 0: Digital setting Preset P0-08, UP/DOWN Can be modified. (non-retentive at power failure) 1: Digital setting Preset P0-08, UP/DOWN Can be modified. (retentive at power failure) 2: AI1 Auxiliary frequency 3: AI2 source B selection 4: Reserved 5: Pulse setting (DI5) 6: Multi-reference 7: Simple PLC 8: PID 9: Communication setting Default Property 1 ★ When used as an independent frequency input channel (frequency source switched over from A to B), the auxiliary frequency source B is used in the same way as the main frequency source A (refer to P0-03). When the auxiliary frequency source is used for operation (frequency source is "A and B operation"), pay attention to the following aspects: www.ssinverter.info SSI700 User Manual Description of Function Codes 1) If the auxiliary frequency source A is digital setting, the preset frequency (P0-08) does not take effect. You can directly adjust the set main frequency by pressing keys and on the operation panel (or using the UP/DOWN function of input terminals). 2) If the auxiliary frequency source is analog input (AI1, AI2) or pulse setting, 100% of the input corresponds to the range of the auxiliary frequency B (set in P0-05 and P0-06). 3) If the auxiliary frequency source is pulse setting, it is similar to analog input. Notes The main frequency source A and auxiliary frequency source B must not use the same channel. That is, P0-03 and P0-04 cannot be set to the same value. Function Code P0-05 P0-06 Parameter Name Setting Range Group P0: Standard Function Parameters Range of auxiliary 0:Relative to maximum frequency B for A and B frequency operation 1: Relative to main frequency A Range of auxiliary frequency B for A and B 0%–150% operation Default Property 0 ☆ 100% ☆ If A and B operation is used, P0-05 and P0-06 are used to set the adjustment range of the auxiliary frequency source. You can set the auxiliary frequency to be relative to either maximum frequency or main frequency A. If relative to main frequency A, the setting range of the auxiliary frequency B varies according to the main frequency A. Function Code P0-07 Parameter Name Setting Range Group P0: Standard Function Parameters Unit's digit (Frequency source selection) 0: Main frequency source A 1: A and B operation (operation relationship determined by ten's digit) 2: Switchover between A and B 3: Switchover between A and "A Frequency source and B operation" selection 4: Switchover between B and "A and B operation" Ten's digit (A and B operation relationship) 0: A+B 1: A-B 2: Maximum 3: Minimum Default Property 00 ☆ It is used to select the frequency setting channel. If the frequency source involves A and B operation, you can set the frequency offset in P0-21 for superposition to the A and B operation result, flexibly satisfying various requirements. Figure 6-1 Frequency setting based on main frequency source A and auxiliary frequency source B www.ssinverter.info SSI700 User Manual Function Code P0-08 Description of Function Codes Parameter Name Setting Range Group P0: Standard Function Parameters 0.00 to maximum frequency Preset frequency (valid when frequency source is digital setting) Default Property 50.00 Hz ☆ If the frequency source is digital setting or terminal UP/DOWN, the value of this parameter is the initial frequency of the AC drive (digital setting). Function Code P0-09 Parameter Name Setting Range Group P0: Standard Function Parameters 0: Same direction 1: Reverse direction Rotation direction Default Property 0 ☆ You can change the rotation direction of the motor just by modifying this parameter without changing the motor wiring. Modifying this parameter is equivalent to exchanging any two ofthe motor's U, V, W wires. Notes The motor will resume running in the original direction after parameter initialization. Do not use this function in applications where changing the rotating direction of the motor is prohibited after system commissioning is complete. Function Code P0-10 Parameter Name Setting Range Group P0: Standard Function Parameters Vector : 50.00–320.00 Hz Maximum frequency V/F : 50.00–3200.00 Hz Default Property 50.00 Hz ★ When the frequency source is AI, pulse setting (DI5), or multi-reference, 100% of the input corresponds to the value of this parameter. The output frequency of the SSI700 can reach up to 3200 Hz. To take both frequency reference resolution and frequency input range into consideration, you can set the number of decimal places for frequency reference in P0-22. www.ssinverter.info SSI700 User Manual Description of Function Codes • If P0-22 is set to 1, the frequency reference resolution is 0.1 Hz. In this case, thesetting range of P0-10 is 50.0 to 3200.0 Hz. • If 0-22 is set to 2, the frequency reference resolution is 0.01 Hz. In this case, the setting range of P0-10 is 50.00 to 320.00 Hz. Notes After the value of P0-22 is modified, the frequency resolution of all frequency related function codes change accordingly. Function Code P0-11 Parameter Name Setting Range Group P0: Standard Function Parameters 0: Set by P0-12 1: AI1 Source of frequency 2: AI2 upper limit 3: Reserved 4: Pulse setting (DI5) 5: Communication setting Default Property 0 ★ It is used to set the source of the frequency upper limit, including digital setting (P0-12), AI,pulse setting or communication setting. If the frequency upper limit is set by means of AI1,AI2, DI5 or communication, the setting is similar to that of the main frequency source A. For details, see the description of P0-03. For example, to avoid runaway in torque control mode in winding application, you can set the frequency upper limit by means of analog input. When the AC drive reaches the upper limit, it will continue to run at this speed. Function Code P0-12 Parameter Name Setting Range Group P0: Standard Function Parameters Frequency lower limit (P0-14) to Frequency upper limit maximum frequency (P0-10) Default Property 50.00 Hz ☆ Default Property 0.00 Hz ☆ This parameter is used to set the frequency upper limit. Function Code P0-13 Parameter Name Setting Range Group P0: Standard Function Parameters Frequency upper limit 0.00 Hz to maximum frequency offset (P0-10) If the source of the frequency upper limit is analog input or pulse setting, the final frequency upper limit is obtained by adding the offset in this parameter to the frequency upper limit set in P0-11. Function Code P0-14 Parameter Name Setting Range Group P0: Standard Function Parameters 0.00 Hz to frequency upper limit (P0-12) Frequency lower limit Default Property 0.00 Hz ☆ If the frequency reference is lower than the value of this parameter, the AC drive can stop, run at the frequency lower limit, or run at zero speed, determined by P8-14. Function Code P0-15 Parameter Name Setting Range Group P0: Standard Function Parameters Carrier frequency 0.5–16.0 kHz Default Property Model dependent ☆ It is used to adjust the carrier frequency of the AC drive, helping to reduce the motor noise, avoiding the resonance of the mechanical system, and reducing the leakage current to the earth and interference generated by the AC drive. www.ssinverter.info SSI700 User Manual Description of Function Codes If the carrier frequency is low, output current has high harmonics, and the power loss and temperature rise of the motor increase. If the carrier frequency is high, power loss and temperature rise of the motor declines. However, the AC drive has an increase in power loss, temperature rise and interference. Adjusting the carrier frequency will exert influences on the aspects listed in the following table. Table 6-1 Influences of carrier frequency adjustment Carrier frequency Motor noise Output current waveform Motor temperature rise AC drive temperature rise Leakage current External radiation interference Low Large Bad High Low Small Small High Small Good Low High Large Large The factory setting of carrier frequency varies with the AC drive power. If you need to modify the carrier frequency, note that if the set carrier frequency is higher than factory setting, it will lead to an increase in temperature rise of the AC drive's heatsink. In this case, you need to de-rate the AC drive. Otherwise, the AC drive may overheat and alarm. Function Code P0-16 Parameter Name Setting Range Group P0: Standard Function Parameters Carrier frequency adjustment 0: No with temperature 1: Yes Default Property 1 ☆ It is used to set whether the carrier frequency is adjusted based on the temperature. The AC drive automatically reduces the carrier frequency when detecting that the heatsink temperature is high. The AC drive resumes the carrier frequency to the set value when the heatsink temperature becomes normal. This function reduces the overheat alarms. Function Code P0-17 P0-18 Parameter Name Setting Range Group P0: Standard Function Parameters 0.00–650.00s (P0-19 = 2) Acceleration time 1 0.0–6500.0s (P0-19 = 1) 0–65000s (P0-19 = 0) 0.00–650.00s (P0-19 = 2) Deceleration time 1 0.0–6500.0s (P0-19 = 1) 0–65000s (P0-19 = 0) Default Property Model dependent ☆ Model dependent ☆ Acceleration time indicates the time required by the AC drive to accelerate from 0 Hz to "Acceleration/Deceleration base frequency" (P0-24), that is, t1 in Figure 6-2. Deceleration time indicates the time required by the AC drive to decelerate from "Acceleration/Deceleration base frequency" (P0-24) to 0 Hz, that is, t2 in Figure 6-2. Figure 6-2 Acceleration/Deceleration time www.ssinverter.info SSI700 User Manual Description of Function Codes The SSI700 provides totally four groups of acceleration/deceleration time for selection. You can perform switchover by using a DI terminal. • Group 1: P0-17, P0-18 • Group 2: P8-03, P8-04 • Group 3: P8-05, P8-06 • Group 4: P8-07, P8-08 Function Code P0-19 Parameter Name Setting Range Group P0: Standard Function Parameters 0:1s Acceleration/Deceleration 1: 0.1s time unit 2: 0.01s Default Property 1 ★ To satisfy requirements of different applications, the SSI700 provides three acceleration/ deceleration time units, 1s, 0.1s and 0.01s. Notes Modifying this parameter will make the displayed decimal places change and corresponding acceleration/deceleration time also change. Function Code P0-21 Parameter Name Setting Range Group P0: Standard Function Parameters Frequency offset of auxiliary 0.00 Hz to maximum frequency source for A and B frequency(P0-10) operation Default Property 0.00 Hz ☆ This parameter is valid only when the frequency source is set to "A and B operation". The final frequency is obtained by adding the frequency offset set in this parameter to the A and B operation result. Function Code P0-22 Parameter Name Setting Range Group P0: Standard Function Parameters Frequency reference 1: 0.1 Hz resolution 2: 0.01 Hz Default Property 2 ★ It is used to set the resolution of all frequency-related parameters. If the resolution is 0.1 Hz, the SSI700 can output up to 3200 Hz. If the resolution is 0.01 Hz, the SSI700 can output up to 600.00 Hz. Notes • Modifying this parameter will make the decimal places of all frequency-related parameters change and corresponding frequency values change. • This parameter is not resumed when factory setting is resumed. Function Code P0-23 Parameter Name Setting Range Group P0: Standard Function Parameters Retentive of digital setting 0: Not retentive frequency upon power failure 1: Retentive Default Property 0 ☆ This parameter is valid only when the frequency source is digital setting. If P0-23 is set to 0, the digital setting frequency value resumes to the value of P0-08 (Preset frequency) after the AC drive stops. The modification by using keys and or the terminal UP/DOWN function is cleared. www.ssinverter.info SSI700 User Manual Description of Function Codes If P0-23 is set to 1, the digital setting frequency value is the set frequency at the moment when the AC drive stops. The modification by using keys and or the terminal UP/ DOWN function remains effective. Function Code Parameter Name P0-24 Acceleration/Deceleration time base frequency Setting Range Group P0: Standard Function Parameters 0: Maximum frequency (P0-10) 1: Set frequency 2: 100 Hz Default Property 0 ★ The acceleration/deceleration time indicates the time for the AC drive to increase from 0 Hz to the frequency set in P0-24. If this parameter is set to 1, the acceleration /deceleration time is related to the set frequency. If the set frequency changes frequently, the motor's acceleration/deceleration also changes. Group P1: Motor Parameters Function Code P1-00 P1-01 P1-02 P1-03 P1-04 P1-05 Parameter Name Setting Range Group P1: Motor 1 Parameters 0: Common asynchronous motor Motor type selection 1: Variable frequency asynchronous motor 0.1–5.5kW Rated motor power Rated motor voltage 1–500 V 0.01–655.35 A (AC drive power Rated motor current ≤55 kW) Rated motor frequency 0.01 Hz to maximum frequency Rated motor rotational 1–65535 RPM speed Default Property 0 ★ Model Dependent Model Dependent ★ ★ Model Dependent ★ Model Dependent ★ Model Dependent ★ Set the parameters according to the motor nameplate no matter whether V/F control or vector control is adopted. To achieve better V/F or vector control performance, motor auto-tuning is required. The motor auto-tuning accuracy depends on the correct setting of motor nameplate parameters. Function Code P1-06 P1-07 P1-08 P1-09 P1-10 Parameter Name Setting Range Group P1: Motor 1 Parameters Stator resistance 0.001–65.535 Ω (AC drive power (asynchronous motor) ≤ 55 kW) Rotor resistance 0.001–65.535 Ω (AC drive power (asynchronous motor) ≤ 55 kW) Leakage inductive 0.01–655.35 mH (AC drive reactance power ≤ 55 kW) (asynchronous motor) Mutual inductive 0.1–6553.5 mH (AC drive power reactance ≤ 55 kW) (asynchronous motor) No-load current 0.01 to P1-03 (AC drive power (asynchronous motor) ≤ 55 kW) Default Property Model dependent ★ Model Dependent ★ Model Dependent ★ Model Dependent ★ Model Dependent ★ The parameters in P1-06 to P1-10 are asynchronous motor parameters. These parameters are unavailable on the motor nameplate and are obtained by means of motor auto-tuning. Only P1-06 to P1-08 can be obtained through static motor auto-tuning. www.ssinverter.info SSI700 User Manual Description of Function Codes Through complete motor auto-tuning, encoder phase sequence and current loop PI can be obtained besides the parameters in P1-06 to P1-10. Each time "Rated motor power" (P1-01) or "Rated motor voltage" (P1-02) is changed, the AC drive automatically restores values of P1-06 to P1-10 to the parameter setting for the common standard B series asynchronous motor. If it is impossible to perform motor auto-tuning onsite, manually input the values of these parameters according to data provided by the motor manufacturer. Function Code P1-11 • Parameter Name Setting Range Group P1: Motor 1 Parameters 0: No auto-tuning 1: Asynchronous motor static Auto-tuning selection auto-tuning 2: Asynchronous motor complete auto-tuning Default Property 0 ★ 0: No auto-tuning Auto-tuning is prohibited. • 1: Asynchronous motor static auto-tuning It is applicable to scenarios where complete auto-tuning cannot be performed because the asynchronous motor cannot be disconnected from the load. Before performing static auto-tuning, properly set the motor type and motor nameplate parameters of P1-00 to P1-05 first. The AC drive will obtain parameters of P1-06 to P1-08 by static auto-tuning. Set this parameter to 1, and press • Then, the AC drive starts static auto-tuning. 2: Asynchronous motor complete auto-tuning To perform this type of auto-tuning, ensure that the motor is disconnected from the load. During the process of complete auto-tuning, the AC drive performs static auto-tuning first and then accelerates to 80% of the rated motor frequency within the acceleration time set in P0-17. The AC drive keeps running for a certain period and then decelerates to stop within deceleration time set in P0-18. Before performing complete auto-tuning, properly set the motor type, motor nameplate parameters of P1-00 to P1-05. Set this parameter to 2, and press Then, the AC drive starts complete autotuning. Notes Motor auto-tuning can be performed only in operation panel mode. Group P2: Vector Control Parameters Group P2 is valid for vector control, and invalid for V/F control. Function Code Parameter Name P2-00 P2-01 P2-02 P2-03 P2-04 Speed loop proportional gain 1 Speed loop integral time 1 Switchover frequency 1 Speed loop proportional gain 2 P2-05 Setting Range Group P2: Vector Control Parameters 0–100 0.01–10.00s 0.00 to P2-05 0–100 Speed loop integral time 2 0.01–10.00s P2-02 to maximum output Switchover frequency 2 frequency Default Property 30 0.50s 5.00HZ 20 1.00s ☆ ☆ ☆ ☆ ☆ 10.0HZ ☆ www.ssinverter.info SSI700 User Manual Description of Function Codes Speed loop PI parameters vary with running frequencies of the AC drive. • If the running frequency is less than or equal to "Switchover frequency 1" (P2-02), the speed loop PI parameters are P2-00 and P2-01. • If the running frequency is equal to or greater than "Switchover frequency 2" (P2-05),the speed loop PI parameters are P2-03 and P2-04. • If the running frequency is between P2-02 and P2-05, the speed loop PI parametersare obtained from the linear switchover between the two groups of PI parameters, as shown in Figure 6-3. Figure 6-3 Relationship between running frequencies and PI parameters The speed dynamic response characteristics in vector control can be adjusted by setting the proportional gain and integral time of the speed regulator. To achieve a faster system response, increase the proportional gain and reduce the integral time. Be aware that this may lead to system oscillation. The recommended adjustment method is as follows: If the factory setting cannot meet the requirements, make proper adjustment. Increase the proportional gain first to ensure that the system does not oscillate, and then reduce the integral time to ensure that the system has quick response and small overshoot. Notes Improper PI parameter setting may cause too large speed overshoot, and overvoltage fault may even occur when the overshoot drops. Function Code P2-06 Parameter Name Setting Range Group P2: Vector Control Parameters Time constant of speed 0.000–0.100s loop filter Default Property 0.000s ☆ For SFVC, it is used to adjust speed stability accuracy of the motor. When the motor with load runs at a very low speed, increase the value of this parameter; when the motor with load runs at a very large speed, decrease the value of this parameter. www.ssinverter.info SSI700 User Manual Function Code P2-07 Parameter Name Description of Function Codes Setting Range Group P2: Vector Control Parameters Vector control slip gain 50%–200% Default Property 100% ☆ In the vector control mode, the output of the speed loop regulator is torque current reference. This parameter is used to filter the torque references. It need not be adjusted generally and can be increased in the case of large speed fluctuation. In the case of motor oscillation, decrease the value of this parameter properly. If the value of this parameter is small, the output torque of the AC drive may fluctuate greatly, but the response is quick. Function Code P2-08 Parameter Name Setting Range Group P2: Vector Control Parameters Vector control 0–200 overexcitation gain Default Property 64 ☆ During deceleration of the AC drive, over-excitation control can restrain rise of the bus voltage to avoid the overvoltage fault. The larger the over-excitation gain is, the better the restraining effect is. Increase the over-excitation gain if the AC drive is liable to overvoltage error during deceleration. Too large over-excitation gain, however, may lead to an increase in output current. Therefore, set this parameter to a proper value in actual applications. Set the over-excitation gain to 0 in applications of small inertia (the bus voltage will not rise during deceleration) or where there is a braking resistor. Function Code P2-09 P2-10 Parameter Name Setting Range Group P2: Vector Control Parameters Digital setting of torque upper limit in speed 0.0%–200.0% control mode 0: P2-10 1: AI1 Torque upper limit 2: AI2 source in speed control 3: Reserved mode 4: Pulse setting (DI5) 5: Communication setting Default Property 150% ☆ 0 ☆ In the speed control mode, the maximum output torque of the AC drive is restricted by P2-10. If the torque upper limit is analog, pulse or communication setting, 100% of the setting corresponds to the value of P2-09, and 100% of the value of P2-09 corresponds to the AC drive rated torque. For details on the AI1, AI2 setting,see the description of the AI curves in group P4. For details on the pulse setting, see the description of P4-28 to P4-32. When the AC drive is in communication with the master, if P2-10 is set to 5 “communication setting”, P2-09 “Digital setting of torque upper limit in speed control mode” can be set via communication from the master. In other conditions, the host computer writes data -100.00% to 100.00% by the communication address 0x1000, where 100.0% corresponds to the value of P2-09. The communication protocol can be Modbus. Function Code P2-13 P2-14 P2-15 P2-16 Parameter Name Excitation adjustment proportional gain Excitation adjustment integral gain Torque adjustment proportional gain Torque adjustment integral gain Setting Range 0~60000 0~60000 0~60000 0~60000 Default 2000 1300 2000 1300 www.ssinverter.info SSI700 User Manual Description of Function Codes These are current loop PI parameters for vector control. These parameters are automatically obtained through "Asynchronous motor complete auto-tuning".and need not be modified. The dimension of the current loop integral regulator is integral gain rather than integral time. Notes that too large current loop PI gain may lead to oscillation of the entire control loop. Therefore, when current oscillation or torque fluctuation is great, manually decrease the proportional gain or integral gain here. Function Code P2-17 Parameter Name Setting Range Group P2: Vector Control Parameters Unit's digit: integral separation 0: Disabled 1: Enabled Speed loop integral property Default Property 0 ☆ Group P3: V/F Control Parameters Group P3 is valid only for V/F control. The V/F control mode is applicable to low load applications (fan or pump) or applications where one AC drive operates multiple motors or there is a large difference between the AC drive power and the motor power. Function Code P3-00 P3-01 Parameter Name Setting Range Group P3: V/F Control Parameters Cut-off frequency of 0.00 Hz to maximum output torque boost frequency 0.0% (fixed torque boost) 0.1%– Torque boost 30.0% Default Property 50.0HZ ★ Model dependent ☆ To compensate the low frequency torque characteristics of V/F control, you can boost the output voltage of the AC drive at low frequency by modifying P3-01. If the torque boost is set to too large, the motor may overheat, and the AC drive may suffer overcurrent. If the load is large and the motor startup torque is insufficient, increase the value of P3-01. If the load is small, decrease the value of P3-01. If it is set to 0.0, the AC drive performs automatic torque boost. In this case, the AC drive automatically calculates the torque boost value based on motor parameters including the stator resistance. P3-00 specifies the frequency under which torque boost is valid. Torque boost becomes invalid when this frequency is exceeded, as shown in the following figure. Figure 6-4 Manual torque boost www.ssinverter.info SSI700 User Manual Function Code P3-02 • Description of Function Codes Parameter Name Setting Range Group P3: V/F Control Parameters 0: Linear V/F 1: Multi-point V/F 2: Square V/F V/F curve setting 3: 1.2-power V/F 4: 1.4-power V/F 6: 1.6-power V/F 8: 1.8-power V/F Default Property 0 ★ 0: Linear V/F It is applicable to common constant torque load. • 1: Multi-point V/F It is applicable to special load such as dehydrator and centrifuge. Any such V/F curve can be obtained by setting parameters of P3-03 to P3-08. • 2: Square V/F It is applicable to centrifugal loads such as fan and pump. • Function Code 3 to 8: V/F curve between linear V/F and square V/F Parameter Name Setting Range Default Property Group P3: V/F Control Parameters P3-03 Multi-point V/F frequency 1 (F1) 0.00 Hz to P3-05 P3-04 Multi-point V/F voltage 1 (V1) 0.0%–100.0% P3-05 Multi-point V/F frequency 2 (F2) P3-03 to P3-07 0.0%–100.0% P3-05 to rated motor frequency (P1-04) 0.0%–100.0% P3-06 Multi-point V/F voltage 2 (V2) P3-07 Multi-point V/F frequency 3 (F3) P3-08 Multi-point V/F voltage 3 (V3) 0.00 Hz 0.0% 0.00 Hz 0.0% 0.00 Hz 0.0% ★ ★ ★ ★ ★ ★ These six parameters are used to define the multi-point V/F curve. The multi-point V/F curve is set based on the motor's load characteristic. The relationship between voltages and frequencies is: V1 < V2 < V3, F1 < F2 < F3 At low frequency, higher voltage may cause overheat or even burnt out of the motor and overcurrent stall or overcurrent protection of the AC drive. Figure 6-5 Setting of multi-point V/F curve www.ssinverter.info SSI700 User Manual Function Code P3-09 Description of Function Codes Parameter Name Setting Range Group P3: V/F Control Parameters V/F slip compensation gain 0%–200.0% Default Property 0.0% ☆ This parameter is valid only for the asynchronous motor. It can compensate the rotational speed slip of the asynchronous motor when the load of the motor increases, stabilizing the motor speed in case of load change. If this parameter is set to 100%, it indicates that the compensation when the motor bears rated load is the rated motor slip. The rated motor slip is automatically obtained by the AC drive through calculation based on the rated motor frequency and rated motor rotational speed in group P1. Generally, if the motor rotational speed is different from the target speed, slightly adjust this parameter. Function Code P3-10 Parameter Name Setting Range Group P3: V/F Control Parameters V/F over-excitation gain 0–200 Default Property 64 ☆ During deceleration of the AC drive, over-excitation can restrain rise of the bus voltage, preventing the overvoltage fault. The larger the over-excitation is, the better the restraining result is. Increase the over-excitation gain if the AC drive is liable to overvoltage error during deceleration. However, too large over-excitation gain may lead to an increase in the output current. Set P3-09 to a proper value in actual applications. Set the over-excitation gain to 0 in the applications where the inertia is small and the bus voltage will not rise during motor deceleration or where there is a braking resistor. Function Code Parameter Name Setting Range Default Property Model dependent ☆ Group P3: V/F Control Parameters P3-11 V/F oscillation suppression gain 0–100 Set this parameter to a value as small as possible in the prerequisite of efficient oscillation suppression to avoid influence on V/F control. Set this parameter to 0 if the motor has no oscillation. Increase the value properly only when the motor has obvious oscillation. The larger the value is, the better the oscillation suppression result will be. When the oscillation suppression function is enabled, the rated motor current and noload current must be correct. Otherwise, the V/F oscillation suppression effect will not be satisfactory. Group P4: Input Terminals The SSI700 provides five DI terminals (DI5 can be used for high-speed pulse input) and 3analog input (AI) terminals. Function Code P4-00 P4-01 P4-02 P4-03 P4-04 Parameter Name DI1 function selection DI2 function selection DI3 function selection DI4 function selection DI5 function selection Remark Default Group P4: Input Terminals 1: Forward RUN (FWD) 2: Reverse RUN (REV) 9: Fault reset (RESET) 12: Multi-reference terminal 1 13: Multi-reference terminal 2 Standard Standard Standard Standard Standard www.ssinverter.info SSI700 User Manual Description of Function Codes The following table lists the functions available for the DI terminals. Table 6-1 Functions of DI terminals Value 0 1 2 Function No function Forward RUN (FWD) Reverse RUN (REV) 3 Three-line control 4 Forward JOG (FJOG) 5 Reverse JOG (RJOG) 6 Terminal UP 7 Terminal DOWN 8 Coast to stop 9 Fault reset (RESET) 10 RUN pause 11 Normally open (NO) input of external fault 12 13 14 15 16 17 18 Multi-reference terminal 1 Multi-reference terminal 2 Multi-reference terminal 3 Multi-reference terminal 4 Terminal1 for acceleration/ deceleration time selection Terminal2 for acceleration/ deceleration time selection Frequency source switchover 19 UP and DOWN setting clear (terminal, operation panel) 20 Command source switchover terminal 21 Acceleration/Deceleration prohibited 22 PID pause 23 PLC status reset Description Set 0 for reserved terminals to avoid malfunction. The terminal is used to control forward or reverse RUN of the AC drive. The terminal determines three-line control of the AC drive. For details, see the description of P4-11. FJOG indicates forward JOG running, while RJOG indicates reverse JOG running. The JOG frequency, acceleration time and deceleration time are described respectively in P8-00, P8-01 and P8-02. If the frequency is determined by external terminals, the terminals with the two functions are used as increment and decrement commands for frequency modification. When the frequency source is digital setting, they are used to adjust the frequency. The AC drive blocks its output, the motor coasts to rest and is not controlled by the AC drive. It is the same as coast to stop described in P6-10. The terminal is used for fault reset function, the same as the function of RESET key on the operation panel. Remote fault reset is implemented by this function. The AC drive decelerates to stop, but the running parameters are all memorized, such as PLC, swing frequency and PID parameters. After this function is disabled, the AC drive resumes its status before stop. If this terminal becomes ON, the AC drive reports Err and performs the fault protection action. For more details, see the description of P9-47. The setting of 16 speeds or 16 other references can be implemented through combinations of 16 states of these four terminals. Totally four groups of acceleration/deceleration time can be selected through combinations of two states of these two terminals. The terminal is used to perform switchover between two frequency sources according to the setting inP0-07 If the frequency source is digital setting, the terminal is used to clear the modification by using the UP/ DOWN function or the increment/decrement key on the operation panel, returning the set frequency to the value of P0-08. If the command source is set to terminal control (P0-01= 1), this terminal is used to perform switchover between terminal control and operation panel control. If the command source is set to communication control (P0-01= 2), this terminal is used to perform switchover between communication control and operation panel control. It enables the AC drive to maintain the current frequency output without being affected by external signals (except the STOP command). PID is invalid temporarily. The AC drive maintains the current frequency output without supporting PID adjustment of frequency source. The terminal is used to restore the original status of PLC control for the AC drive when PLC control is started again after a pause. www.ssinverter.info SSI700 User Manual Value Function 24 Swing pause 25 26 27 28 Counter input Counter reset Length count input Length reset 29 30 31 32 33 34 35 Torque control prohibited Pulse input (enabled only for DI5) Reserved Immediate DC braking Normally closed (NC) input of external fault Frequency modification forbidden Reverse PID action direction 36 External STOP terminal 1 37 Command source switchover terminal 2 38 PID integral pause 41,42 Switchover between main frequency source A and preset frequency Switchover between auxiliary frequency source B and preset frequency Reserved 43 PID parameter switchover 39 40 44,45 Reserved 46 Speed control/Torque control switchover 47 Emergency stop 48 External STOP terminal 2 49 Deceleration DC braking 50 Clear the current running time Description of Function Codes Description The AC drive outputs the central frequency, and the swing frequency function pauses. This terminal is used to count pulses. This terminal is used to clear the counter status. This terminal is used to count the length. This terminal is used to clear the length. The AC drive is prohibited from torque control and enters the speed control mode. DI5 is used for pulse input. Reserved. After this terminal becomes ON, the AC drive directly switches over to the DC braking state. After this terminal becomes ON, the AC drive reports Err and stops. After this terminal becomes ON, the AC drive does not respond to any frequency modification. After this terminal becomes ON, the PID action direction is reversed to the direction set in 10-03. In operation panel mode, this terminal can be used to stop the AC drive, equivalent to the function of the STOP key on the operation panel. It is used to perform switchover between terminal control and communication control. If the command source is terminal control, the system will switch over to communication control after this terminal becomes ON. After this terminal becomes ON, the integral adjustment function pauses. However, the proportional and differentiation adjustment functions are still valid. After this terminal becomes ON, the frequency source A is replaced by the preset frequency set in P0-08. After this terminal is enabled, the frequency source B is replaced by the preset frequency set in P0-08. Reserved. If the PID parameters switchover performed by means of DI terminal (10-18 =1), the PID parameters are 10-05 to 10-07 when the terminal becomes OFF; the PID parameters are 10-15 to 10-17 when this terminal becomes ON. Reserved. This terminal enables the AC drive to switch over between speed control and torque control. When this terminal becomes OFF, the AC drive runs in the mode set in 17-00. When this terminal becomes ON, the AC drive switches over to the other control mode. When this terminal becomes ON, the AC drive stops within the shortest time. During the stop process, the current remains at the set current upper limit. In any control mode (operation panel, terminal or communication), it can be used to make the AC drive decelerate to stop. In this case, the deceleration time is deceleration time 4. When this terminal becomes ON, the AC drive decelerates to the initial frequency of stop DC braking and then switches over to DC braking state. When this terminal becomes ON, the AC drive's current running time is cleared. This function must be supported by P8-42 and P8-53. www.ssinverter.info SSI700 User Manual Description of Function Codes The four multi-reference terminals have 16 state combinations, corresponding to 16 reference values, as listed in the following table. Table 6-2 State combinations of the four multi-reference terminals K4 K3 K2 K1 OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON ON ON ON ON ON OFF OFF OFF OFF ON ON ON ON OFF OFF OFF OFF ON ON ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON Reference Setting Reference 0 Reference 1 Reference 2 Reference 3 Reference 4 Reference 5 Reference 6 Reference 7 Reference 8 Reference 9 Reference 10 Reference 11 Reference 12 Reference 13 Reference 14 Reference 15 Corresponding Parameter 12-00 12-01 12-02 12-03 12-04 12-05 12-06 12-07 12-08 12-09 12-10 12-11 12-12 12-13 12-14 12-15 If the frequency source is multi-reference, the value 100% of 12-00 to 12-15 corresponds to the value of P0-10 (Maximum frequency). Besides the multi-speed function, the multi-reference can be also used as the PID setting source or the voltage source for V/F separation, satisfying the requirement on switchover ofdifferent setting values. Two terminals for acceleration/deceleration time selection have four state combinations, as listed in the following table. Table 6-3 State combinations of two terminals for acceleration/deceleration time selection Terminal 2 Terminal 1 OFF OFF ON ON OFF ON OFF ON Function Code P4-10 Parameter Name DI filter time Acceleration/Deceleration Time Selection Acceleration/Deceleration time 1 Acceleration/Deceleration time 2 Acceleration/Deceleration time 3 Acceleration/Deceleration time 4 Setting Range Group P4: Input Terminals 0.000–1.000s Corresponding Parameters P0-17, P0-18 P8-03, P8-04 P8-05, P8-06 P8-07, P8-08 Default Property 0.010s ☆ It is used to set the software filter time of DI terminal status. If DI terminals are liable to interference and may cause malfunction, increase the value of this parameter to enhance the anti-interference capability. However, increase of DI filter time will reduce the response of DI terminals. Function Code P4-11 Parameter Name Terminal command mode Setting Range Group P4: Input Terminals 0: Two-line mode 1 1: Two-line mode 2 2: Three-line mode 1 3: Three-line mode 2 Default Property 1 ★ This parameter is used to set the mode in which the AC drive is controlled by external terminals. The following uses DI1, DI2 and DI3 among DI1 to DI5 as an example, with allocating functions of DI1, DI2 and DI3 by setting P4-00 to P4-02. www.ssinverter.info SSI700 User Manual Description of Function Codes • 0: Two-line mode 1 It is the most commonly used two-line mode, in which the forward/reverse rotation of the motor is decided by DI1 and DI2. The parameters are set as below: Function Code P4-11 P4-00 P4-01 Parameter Name Value Function Description Terminal command mode DI1 function selection DI2 function selection 0 1 2 Two-line 1 Forward RUN (FWD) Reverse RUN (REV) Figure 6-7 Setting of two-line mode 1 K1 K2 1 0 0 1 RUN command Forward RUN Reverse RUN 1 1 Stop 0 0 Stop As shown in the preceding figure, when only K1 is ON, the AC drive instructs forward rotation. When only K2 is ON, the AC drive instructs reverse rotation. When K1 and K2 are ON or OFF simultaneously, the AC drive stops. • 1: Two-line mode 2 In this mode, DI1 is RUN enabled terminal, and DI2 determines the running direction. The parameters are set as below: Function Code P4-11 P4-00 P4-01 Parameter Name Value Function Description Terminal command mode DI1 function selection DI2 function selection 1 1 2 Two-line 1 Forward RUN (FWD) Reverse RUN (REV) Figure 6-8 Setting of two-line mode 2 K1 K2 1 0 1 1 RUN command Forward RUN Reverse RUN 0 0 Stop 0 1 Stop As shown in the preceding figure, if K1 is ON, the AC drive instructs forward rotation when K2 is OFF, and instructs reverse rotation when K2 is ON. If K1 is OFF, the AC drive stops. • 2: Three-line mode 1 In this mode, DI3 is RUN enabled terminal, and the direction is decided by DI1 and DI2. The parameters are set as below: www.ssinverter.info SSI700 User Manual Function Code P4-11 P4-00 P4-01 P4-02 Description of Function Codes Parameter Name Value Function Description Terminal command mode DI1 function selection DI2 function selection DI3 function selection 2 1 2 3 Two-line 1 Forward RUN (FWD) Reverse RUN (REV) Three-line control Figure 6-9 Setting of three-line mode 1 As shown in the preceding figure, if SB1 is ON, the AC drive instructs forward rotation when SB2 is pressed to be ON and instructs reverse rotation when SB3 is pressed to be ON. The AC drive stops immediately after SB1 becomes OFF. During normal startup and running, SB1 must remain ON. The AC drive's running state is determined by the final actions on SB1, SB2 and SB3. • 3: Three-line mode 2 In this mode, DI3 is RUN enabled terminal. The RUN command is given by DI1 and the direction is decided by DI2. The parameters are set as below: Function Code P4-11 P4-00 P4-01 P4-02 Parameter Name Value Function Description Terminal command mode DI1 function selection DI2 function selection DI3 function selection 3 1 2 3 Two-line 2 Forward RUN (FWD) Reverse RUN (REV) Three-line control Figure 6-10 Setting of three-line mode 2 K 0 1 RUN command Forward RUN Reverse RUN www.ssinverter.info SSI700 User Manual Description of Function Codes As shown in the preceding figure, if SB1 is ON, the AC drive starts running when SB2 is pressed to be ON; the AC drive instructs forward rotation when K is OFF and instructs reverse rotation when K is ON. The AC drive stops immediately after SB1 becomes OFF. During normal startup and running, SB1 must remain ON. The AC drive's running state is determined by the final actions of SB1, SB2 and K. Function Code P4-12 Parameter Name Setting Range Group P4: Input Terminals Terminal UP/DOWN rate 0.01–65.535 Hz/s Default Property 1.0 Hz/s ☆ It is used to adjust the rate of change of frequency when the frequency is adjusted by means of terminal UP/DOWN. • If P0-22(Frequency reference resolution)is 2, the setting range is 0.001–65.535 Hz/s. • If P0-22 (Frequency reference resolution) is 1, the setting range is 0.01–655.35 Hz/s. Function Code P4-13 P4-14 P4-15 P4-16 P4-17 Parameter Name Setting Range Group P4: Input Terminals 0.00 V to P4-15 AI1curve minimum input Corresponding setting of AI -100.00%+100.0% curve 1 minimum input P4-13 to 10.00 V AI1curve maximum input Corresponding setting of -100.00%+100.0% AI1curve maximum input 0.00–10.00s AI1 filter time Default Property 0.00 V ☆ 0.0% ☆ 10.00V 100.0 % 0.10s ☆ ☆ ☆ These parameters are used to define the relationship between the analog input voltage and the corresponding setting. When the analog input voltage exceeds the maximum value(P4-15), the maximum value is used. When the analog input voltage is less than the minimum value(P4-13), the value set in P4-34(Setting for AI less than minimum input) is used. When the analog input is current input, 1 mA current corresponds to 0.5 V voltage. P4-17 (AI1 filter time) is used to set the software filter time of AI1. If the analog input is liable to interference, increase the value of this parameter to stabilize the detected analog input. However, increase of the AI filter time will slow the response of analog detection. Set this parameter properly based on actual conditions. In different applications, 100% of analog input corresponds to different nominal values. For details, refer to the description of different applications. Two typical setting examples are shown in the following figure. Figure 6-11 Corresponding relationship between analog input and set values www.ssinverter.info SSI700 User Manual Function Code P4-18 P4-19 P4-20 P4-21 P4-22 Description of Function Codes Parameter Name Setting Range Group P4: Input Terminals AI2 curve minimum input 0.00 V to P4-20 Corresponding setting of AI2 -100.00%+100.0% curve minimum input AI2 curve maximum input P4-18 to 10.00 V Corresponding setting of AI2 -100.00%+100.0% curve maximum input 0.00–10.00s AI2 filter time Default Property 0.00 V ☆ 0.0% ☆ 10.00V 100.0 % 0.10s ☆ ☆ ☆ The method of setting AI2 functions is similar to that of setting AI1 function. Function Code Parameter Name Setting Range Default Property 0.00 kHz ☆ 0.0% ☆ Group P4: Input Terminals P4-28 Pulse minimum input 0.00 kHz to P4-30 P4-29 Corresponding setting of pulse minimum input -100.00%–100.0% P4-30 P4-31 P4-32 Pulse maximum input 50.00 kHz 100.0 % 0.10s P4-28 to 50.00 kHz Corresponding setting of pulse maximum input Pulse filter time -100.00%+100.0% 0.00–10.00s ☆ ☆ ☆ These parameters are used to set the relationship between DI5 pulse input and corresponding settings. The pulses can only be input by DI5. The method of setting this function is similar to that of setting AI1 function. Function Code P4-33 Parameter Name Setting Range AI curve selection Unit's digit (AI1 curve selection) Curve 1 (2 points, see P4-13 to P4-16) Curve 2 (2 points, see P4-18 to P4-21) Ten's digit (AI2 curve selection) Curve1 to curve 5 (same as AI1) Default Property 321 ☆ The unit's digit, ten's digit and hundred's digit of this parameter are respectively used to select the corresponding curve of AI1, AI2. Any of the five curves can be selected for AI1, AI2. Curve 1, curve 2 and curve 3 are all 2-point curves, set in group P4. Curve 4 and curve 5 are both 4-point curves. The SSI700 provides two AI terminals as standard. Function Code P4-34 Parameter Name Setting Range Group P4: Input Terminals Unit's digit (Setting for AI1 less than minimum input) 0: Minimum value Setting for AI less than 1: 0.0% minimum input Ten's digit (Setting for AI2 less than minimum input) 0, 1 (same as AI1) Default Property 000 ☆ This parameter is used to determine the corresponding setting when the analog input voltage is less than the minimum value. The unit's digit, ten's digit and hundred's digit of this parameter respectively correspond to the setting for AI2, AI2. If the value of a certain digit is 0, when analog input voltage is less than the minimum input, the corresponding setting of the minimum input (P4-14, P4-19, P4-24) is used. www.ssinverter.info SSI700 User Manual Description of Function Codes If the value of a certain digit is 1, when analog input voltage is less than the minimum input, the corresponding value of this analog input is 0.0%. Function Code P4-35 P4-36 Parameter Name DI1 delay time DI2 delay time Setting Range Group P4: Input Terminals 0.0–3600.0s 0.0–3600.0s Default Property 0.0s 0.0s ★ ★ These parameters are used to set the delay time of the AC drive when the status of DI terminals changes. Currently, only DI1, DI2 support the delay time function. Function Code P4-38 Parameter Name DI valid mode selection1 Setting Range Default Unit's digit (DI1 valid mode) 0: High level valid 1: Low level valid Ten's digit (DI2 valid mode) 0, 1 (same as DI1) Hundred's digit (DI3 valid mode) 0, 1 (same as DI1) Thousand's digit(DI4 valid mode) 0, 1 (same as DI1) Ten thousand's digit(DI5 valid mode) 0, 1 (same as DI1) 00000 Property ★ These parameters are used to set the valid mode of DI terminals. • 0: High level valid The DI terminal is valid when being connected with COM, and invalid when being disconnected from COM. • 1: Low level valid The DI terminal is invalid when being connected with COM, and invalid when being disconnected from COM. Group F5: Output Terminals The SSI700 provides an analog output (AO) terminal, a digital output (DO) terminal, a relay terminal and a FM terminal (used for high-speed pulse output or open-collector switch signal output) as standard. Function Code P5-00 Parameter Name Setting Range Group P5: Output Terminals 0: Pulse output (FMP) FM terminal output mode 1: Switch signal output (FMR) Default Property 0 ☆ The FM terminal is programmable multiplexing terminal. It can be used for high-speed pulse output (FMP), with maximum frequency of 100Hz. Refer to P5-06 for relevant functions of FMP. It can also be used as open collector switch signal output (FMR). Function Code P5-01 P5-02 P5-04 Parameter Name FMR function (opencollector output terminal) Relay function (T/A-T/B-T/C) DO1 function selection (open-collector output terminal) Default 0 2 4 www.ssinverter.info SSI700 User Manual Description of Function Codes These five parameters are used to select the functions of the five digital output terminals. T/A-T/B-T/C are respectively the relays on the control board . The functions of the output terminals are described in the following table. Table 6-5 Functions of output terminals Value Function 0 No output 1 AC drive running 2 Fault output (stop) 3 4 Frequency-level detection BRAKE control 1 output Frequency reached 5 Zero-speed running (no output at stop) 6 Motor overload pre-warning 7 AC drive overload prewarning 8 Set count value reached 9 Designated count value reached 10 Length reached 11 PLC cycle complete 12 Accumulative running time reached 13 Frequency limited 14 Torque limited 15 Ready for RUN 16 AI1 larger than AI2 17 Frequency upper limit reached 18 Frequency lower limit reached (no output at stop) 19 Undervoltage state output 20 21,22 23 24 25 Communication Reserved Zero-speed running 2 (having output at stop) Accumulative poweron time reached Frequency level detection BRAKE control 2 output Description The terminal has no function. When the AC drive is running and has output frequency (can be zero), the terminal becomes ON. When the AC drive stops due to a fault, the terminal becomes ON. Refer to the descriptions of P8-19 and P8-20. Refer to the descriptions of P8-21. If the AC drive runs with the output frequency of 0, the terminal becomes ON. If the AC drive is in the stop state, the terminal becomes OFF. The AC drive judges whether the motor load exceeds the overload pre-warning threshold before performing the protection action. If the pre-warning threshold is exceeded, the terminal becomes ON. For motor overload parameters,see the descriptions of P9-00 to P9-02. The terminal becomes ON 10s before the AC drive overload protection action is performed. The terminal becomes ON when the count value reaches the value set in 11-08. The terminal becomes ON when the count value reaches the value set in 11-09. The terminal becomes ON when the detected actual length exceeds the value set in 11-05. When simple PLC completes one cycle, the terminal outputs a pulse signal with width of 250 ms. If the accumulative running time of the AC drive exceeds the time set in P8-17, the terminal becomes ON. If the set frequency exceeds the frequency upper limit or lower limit and the output frequency of the AC drive reaches the upper limit or lower limit, the terminal becomes ON. In speed control mode, if the output torque reaches the torque limit, the AC drive enters the stall protection state and meanwhile the terminal becomes ON. If the AC drive main circuit and control circuit become stable, and the AC drive detects no fault and is ready for RUN, the terminal becomes ON. When the input of AI1 is larger than the input of AI2, the terminal becomes ON. If the running frequency reaches the upper limit, the terminal becomes ON. If the running frequency reaches the lower limit, the terminal becomes ON. In the stop state, the terminal becomes OFF. If the AC drive is in undervoltage state, the terminal becomes ON. setting Refer to the communication protocol. Reserved. If the output frequency of the AC drive is 0, the terminal becomes ON. In the state of stop, the signal is still ON. If the AC drive accumulative power-on time (P7-13) exceeds the value set in P8-16, the terminal becomes ON. Refer to the descriptions of P8-28 and P8-29. www.ssinverter.info SSI700 User Manual Value Description of Function Codes 26 27 28 29 Function Frequency 1 reached Frequency 2 reached Current 1 reached Current 2 reached 30 Timing reached 31 AI1 input limit exceeded 32 Load becoming 0 33 Reverse running 34 Zero current state 35 Module temperature reached 36 Software current limit Frequency lower limit reached (having output at stop) 37 38 Alarm output 39 Motor overheat warning 40 Current running time reached Function Code P5-06 P5-07 Description Refer to the descriptions of P8-30 and P8-31. Refer to the descriptions of P8-32 and P8-33. Refer to the descriptions of P8-38 and P8-39. Refer to the descriptions of P8-40 and P8-41. If the timing function (P8-42) is valid, the terminal becomes ON after the current running time of the AC drive reaches the set time. If AI1 input is larger than the value of P8-46 (AI1 input voltage upper limit) or lower than the value of P8-45 (AI1 input voltage lower limit), the terminal becomes ON. If the load becomes 0, the terminal becomes ON. If the AC drive is in the reverse running state, the terminal becomes ON. Refer to the descriptions of P8-28 and P8-29. If the heatsink temperature of the inverter module (P7-07) reaches the set module temperature threshold (P8-47), the terminal becomes ON. exceeded Refer to the descriptions of P8-36 and P8-37. If the running frequency reaches the lower limit, the terminal becomes ON. In the stop state, the signal is still ON. If a fault occurs on the AC drive and the AC drive continues to run, the terminal outputs the alarm signal. If the motor temperature reaches the temperature set in P9-58 (Motor overheat warning threshold), the terminal becomes ON. You can view the motor temperature by using . If the current running time of AC drive exceeds the value of P8-53, the terminal becomes ON. Parameter Name Default Group P5: Output Terminals FMP function selection 0: Running frequency AO1 function selection The output pulse frequency of the FMP terminal ranges from 0.01 kHz to "Maximum FMP output frequency" (P5-09). The value of P5-09 is between 0.01 kHz and 100.00 kHz. The output range of AO1. The relationship between pulse and analog output ranges and corresponding functions is listed in the following table. Table 6-6 Relationship between pulse and analog output ranges and corresponding functions Value Function 0 1 2 3 4 5 6 7 8 9 10 11 12 Running frequency Set frequency Output current Output torque (absolute value) Output power Output voltage Pulse input AI1 AI2 Reserved Length Count value Communication setting Range (Corresponding to Pulse or Analog Output Range 0.0%–100.0%) 0 to maximum output frequency 0 to maximum output frequency 0 to 2 times of rated motor current 0 to 2 times of rated motor torque 0 to 2 times of rated power 0 to 1.2 times of rated AC drive voltage 0.01–100.00 kHz 0–10 V 0–10 V (or 0–20 mA) 0 to maximum set length 0 to maximum count value 0.0%–100.0% www.ssinverter.info SSI700 User Manual Value Function 13 Motor rotational speed 14 15 16 Output current Output voltage reserved Function Code P5-09 Parameter Name Description of Function Codes Range (Corresponding to Pulse or Analog Output Range 0.0%–100.0%) 0 to rotational speed corresponding to maximum output frequency 0.0–1000.0 A 0.0–000.0 V Setting Range Group P5: Output Terminals Maximum FMP output 0.01–100.00 kHz frequency Default Property 50.00 kHz ☆ If the FM terminal is used for pulse output, this parameter is used to set the maximum frequency of pulse output. Function Code P5-10 P5-11 Parameter Name AO1 offset coefficient AO1 gain Setting Range Group P5: Output Terminals -100.0%–100.0% -10.00–10.00 Default Property 0.0% 1.00 ☆ ☆ These parameters are used to correct the zero drift of analog output and the output amplitude deviation. They can also be used to define the desired AO curve. If "b" represents zero offset, "k" represents gain, "B" represents actual output, and "A" represents standard output, the actual output is: B = kA + b. The zero offset coefficient 100% of AO1 corresponds to 10 V (or 20 mA). The standard output refers to the value corresponding to the analog output of 0 to 10 V (or 0 to 20 mA) with no zero offset or gain adjustment. For example, if the analog output is used as the running frequency, and it is expected that the output is 8 V when the frequency is 0 and 3 V at the maximum frequency, the gain shall be set to -0.50, and the zero offset shall be set to 80%. Function Code P5-17 P5-18 P5-20 Parameter Name Setting Range Group P5: Output Terminals 0.0–3600.0s FMR output delay time Relay output delay time 0.0–3600.0s 0.0–3600.0s DO1 output delay time Default Property 0.0s 0.0s 0.0s ☆ ☆ ☆ These parameters are used to set the delay time of output terminals FMR, relay, DO1 from status change to actual output. Function Code P5-22 Parameter Name Setting Range Group P5: Output Terminals Unit's digit (FMR valid mode) 0: Positive logic 1: Negative logic DO valid mode selection Ten's digit (Relay valid mode) 0, 1 (same as FMR) Thousand's digit (DO1 valid mode) 0, 1 (same as FMR) Default Property 00000 ☆ It is used to set the logic of output terminals FMR, relay, DO1. www.ssinverter.info SSI700 User Manual Description of Function Codes • 0: Positive logic The output terminal is valid when being connected with COM, and invalid when being disconnected from COM. • 1: Positive logic The output terminal is invalid when being connected with COM, and valid when being disconnected from COM. Group P6: Start/Stop Control Function Code P6-00 • Parameter Name Start mode Setting Range Group P6: Start/Stop Control 0: Direct start 1: Rotational speed tracking restart 2: Pre-excited start (asynchronous motor) Default Property 0 ☆ 0: Direct start –– If the DC braking time is set to 0, the AC drive starts to run at the startup frequency. –– If the DC braking time is not 0, the AC drive performs DC braking first and then starts to run at the startup frequency. It is applicable to small-inertia load application where the motor is likely to rotate at startup. • 1: Rotational speed tracking restart The AC drive judges the rotational speed and direction of the motor first and then starts at the tracked frequency. Such smooth start has no impact on the rotating motor. It is applicable to the restart upon instantaneous power failure of large-inertia load. To ensure the performance of rotational speed tracking restart, set the motor parameters in group P1 correctly. • 2: Pre-excited start (asynchronous motor) It is valid only for asynchronous motor and used for building the magnetic field before the motor runs. For pre-excited current and pre-excited time, see parameters of P6-05 and P6-06. –– If the pre-excited time is 0, the AC drive cancels pre-excitation and starts to run at startup frequency. –– If the pre-excited time is not 0, the AC drive pre-excites first before startup, improving the dynamic response of the motor. Function Code P6-01 P6-04 Parameter Name Setting Range Group P6: Start/Stop Control Startup frequency 0.00–10.00 Hz Startup frequency holdingtime 0.0–100.0s Default Property 0.00 Hz 0.0s ☆ ★ To ensure the motor torque at AC drive startup, set a proper startup frequency. In addition, to build excitation when the motor starts up, the startup frequency must be held for a certain period. The startup frequency (P6-01) is not restricted by the frequency lower limit. If the set target frequency is lower than the startup frequency, the AC drive will not start and stays in the standby state. During switchover between forward rotation and reverse rotation, the startup frequency holding time is disabled. The holding time is not included in the acceleration time but in the running time of simple PLC. www.ssinverter.info SSI700 User Manual Description of Function Codes Example 1: P0-00 = 0 P0-08 = 2.00 Hz P0-00 = 5.00 Hz P6-04 = 2.0s The frequency source is digital setting. The digital setting frequency is 2.00 Hz. The startup frequency is 5.00 Hz. The startup frequency holding time is 2.0s. In this example, the AC drive stays in the standby state and the output frequency is 0.00Hz. Example 2: P0-00 = 0 P0-08 = 10.00 Hz P0-00 = 5.00 Hz P6-04 = 2.0s The frequency source is digital setting. The digital setting frequency is 10.00 Hz. The startup frequency is 5.00 Hz. The startup frequency holding time is 2.0s. In this example, the AC drive accelerates to 5.00 Hz, and then accelerates to the set frequency 10.00 Hz after 2s. Function Code P6-02 Parameter Name Rotational speed tracking mode Setting Range Default Property 0 ★ Group P6: Start/Stop Control 0: From frequency at stop 1: From zero speed 2: From maximum frequency To complete the rotational speed tracking process within the shortest time, select the proper mode in which the AC drive tracks the motor rotational speed. • 0: From frequency at stop It is the commonly selected mode. • 1: From zero frequency It is applicable to restart after a long time of power failure. • 2: From the maximum frequency It is applicable to the power-generating load. Function Code Parameter Name Setting Range Default Property 20 ☆ Group P6: Start/Stop Control P6-03 Rotational speed tracking speed 1–100 In the rotational speed tracking restart mode, select the rotational speed tracking speed. The larger the value is, the faster the tracking is. However, too large value may cause unreliable tracking. Function Code P6-05 P6-06 Parameter Name Setting Range Group P6: Start/Stop Control Startup DC braking current/Pre-excited current 0%–100% Startup DC braking time/Pre-excited time 0.0–100.0s Default 0% 0.0s Startup DC braking is generally used during restart of the AC drive after the rotating motor stops. Pre-excitation is used to make the AC drive build magnetic field for the asynchronous motor before startup to improve the responsiveness. Startup DC braking is valid only for direct start (P6-00 = 0). In this case, the AC drive performs DC braking at the set startup DC braking current. After the startup DC braking time, the AC drive starts to run. If the startup DC braking time is 0, the AC drive starts directly without DC braking. The larger the startup DC braking current is, the larger the braking force is. www.ssinverter.info SSI700 User Manual Description of Function Codes If the startup mode is pre-excited start (P6-00 = 3), the AC drive builds magnetic field based on the set pre-excited current. After the pre-excited time, the AC drive starts to run. If the pre-excited time is 0, the AC drive starts directly without pre-excitation. The startup DC braking current or pre-excited current is a percentage relative to the base value. • If the rated motor current is less than or equal to 80% of the rated AC drive current, the base value is the rated motor current. • If the rated motor current is greater than 80% of the rated AC drive current, the base value is 80% of the rated AC drive current. Function Code P6-07 Parameter Name Setting Range Acceleration/ Deceleration mode Default Property 0 ★ Group P6: Start/Stop Control 0: Linear acceleration/deceleration 1: S-curve acceleration/deceleration A 2: S-curve acceleration/deceleration B It is used to set the frequency change mode during the AC drive start and stop process. • 0: Linear acceleration/deceleration The output frequency increases or decreases in linear mode. The SSI700 provides four group of acceleration/deceleration time, which can be selected by using P4-00 to P4-08. • 1: S-curve acceleration/deceleration A The output frequency increases or decreases along the S curve. This mode is generally used in the applications where start and stop processes are relatively smooth, such as elevator and conveyor belt. P6-08 and P6-09 respectively define the time proportions of the start segment and the end segment. • 2: S-curve acceleration/deceleration B f In this curve, the rated motor frequency b is always the inflexion point. This mode is usually used in applications where acceleration/deceleration is required at the speed higher than the rated frequency. When the set frequency is higher than the rated frequency, the acceleration/ deceleration time is: In the formula, f is the set frequency, b f is the rated motor frequency and T is the acceleration time from 0 Hz to b f . Function Code P6-08 P6-09 Parameter Name Setting Range Group P6: Start/Stop Control Time proportion of S-curve start segment 0.0% to (100.0% – P6-09) Time proportion of S-curve end segment 0.0% to (100.0% – P6-08) Default 30.0% 30.0% These two parameters respectively define the time proportions of the start segment and the end segment of S-curve acceleration/deceleration. They must satisfy the requirement: P6-08 + P6-09 ≤ 100.0%. In Figure 6-12, t1 is the time defined in P6-08, within which the slope of the output frequency change increases gradually. t2 is the time defined in P6-09, within which the slope of the output frequency change gradually decreases to 0. Within the time between www.ssinverter.info SSI700 User Manual Description of Function Codes t1 and t2, the slope of the output frequency change remains unchanged, that is, linear acceleration/deceleration. Figure 6-12 S-curve acceleration/deceleration A Figure 6-13 S-curve acceleration/deceleration B Function Code P6-10 Parameter Name Stop mode Setting Range Group P6: Start/Stop Control 0: Decelerate to stop 1: Coast to stop Default Property 0 ☆ • 0: Decelerate to stop After the stop command is enabled, the AC drive decreases the output frequency according to the deceleration time and stops when the frequency decreases to zero. • 1: Coast to stop www.ssinverter.info SSI700 User Manual Description of Function Codes After the stop command is enabled, the AC drive immediately stops the output. The motor will coast to stop based on the mechanical inertia. Function Code P6-11 P6-12 P6-13 P6-14 • Parameter Name Setting Range Group P6: Start/Stop Control Initial frequency of stop 0.00 Hz to maximum frequency DC braking Waiting time of stop DC 0.0–100.0s braking Stop DC braking current 0%–100% Stop DC braking time 0.0–100.0s Default Property 0.00 Hz ☆ 0.0s ☆ 0% 0.0s ☆ ☆ P6-11 (Initial frequency of stop DC braking) During the process of decelerating to stop, the AC drive starts DC braking when the running frequency is lower than the value set in P6-11. • P6-12 (Waiting time of stop DC braking) When the running frequency decreases to the initial frequency of stop DC braking, the AC drive stops output for a certain period and then starts DC braking. This prevents faults such as overcurrent caused due to DC braking at high speed. • P6-13 (Stop DC braking current) This parameter specifies the output current at DC braking and is a percentage relative to the base value. –– If the rated motor current is less than or equal to 80% of the rated AC drive current, the base value is the rated motor current. –– If the rated motor current is greater than 80% of the rated AC drive current, the base value is 80% of the rated AC drive current. • P6-14 (Stop DC braking time) This parameter specifies the holding time of DC braking. If it is set to 0, DC braking is cancelled. The stop DC braking process is shown in the following figure. Figure 6-14 Stop DC braking process www.ssinverter.info SSI700 User Manual Function Code P6-15 Parameter Name Brake use ratio Description of Function Codes Setting Range Default Property Group P6: Start/Stop Control 0%–100% 100% ☆ It is valid only for the AC drive with internal braking unit and used to adjust the duty ratio of the braking unit. The larger the value of this parameter is, the better the braking result will be. However, too larger value causes great fluctuation of the AC drive bus voltage during the braking process. Group P7: Operation Panel and Display Function Code P7-01 Parameter Name Setting Range Group P7: Operation Panel and Display 0:APP key disabled 1: Switchover between operation panel control and remote command control (terminal or APP Key function communication) selection 2: Switchover between forward rotation and reverse rotation 3: Forward JOG 4: Reverse JOG Default Property 0 ★ APP key refers to multifunctional key. You can set the function of the APP key by using this parameter. You can perform switchover by using this key both in stop or running state. • 0: APP key disabled This key is disabled. • 1: Switchover between operation panel control and remote command control (terminal or communication) You can perform switchover from the current command source to the operation panel control (local operation). If the current command source is operation panel control, this key is invalid. • 2: Switchover between forward rotation and reverse rotation You can change the direction of the frequency reference by using the APP key. It is valid only when the current command source is operation panel control. • 3: Forward JOG You can perform forward JOG (FJOG) by using the APP key. • 4: Reverse JOG You can perform reverse JOG (FJOG) by using the APP key. Function Code P7-02 Parameter Name Setting Range Group P7: Operation Panel and Display 0: STOP/RESET key enabled STOP/RESET key only in operation panel control function 1: STOP/RESET key enabled in any operation mode Default Property 1 ☆ www.ssinverter.info SSI700 User Manual Function Code Parameter Name Description of Function Codes Setting Range Default Group P7: Operation Panel and Display P7-03 LED display running parameters 1 1F If a parameter needs to be displayed during the running, set the corresponding bit to 1, and set P7-03 to the hexadecimal equivalent of this binary number. www.ssinverter.info SSI700 User Manual Function Code Parameter Name Description of Function Codes Setting Range Default Group P7: Operation Panel and Display P7-04 LED display running parameters 2 0 If a parameter needs to be displayed during the running, set the corresponding bit to 1, and set P7-03 to the hexadecimal equivalent of this binary number. These two parameters are used to set the parameters that can be viewed when the AC drive is in the running state. You can view a maximum of 32 running state parameters that are displayed from the lowest bit of P7-03. www.ssinverter.info SSI700 User Manual Function Code Description of Function Codes Parameter Name Setting Range Default Group P7: Operation Panel and Display P7-05 LED display stop parameters 0 If a parameter needs to be displayed during the running, set the corresponding bit to 1, and set P7-05 to the hexadecimal equivalent of this binary number. Function Code P7-06 Parameter Name Load speed display coefficient Setting Range 0.0001–6.5000 Default Property 1.0000 ☆ This parameter is used to adjust the relationship between the output frequency of the AC drive and the load speed. For details, see the description of P7-12. Function Code Parameter Name P7-07 Heatsink temperature of inverter module Setting Range Default Property -- ● 0.0–100.0°C It is used to display the insulated gate bipolar transistor (IGBT) temperature of the inverter module, and the IGBT overheat protection value of the inverter module depends on the model. Function Code P7-08 Parameter Name Temporary software version Setting Range Default Property -- ● -- IIt is used to display the temporary software version of the control board. www.ssinverter.info SSI700 User Manual Function Code P7-09 Parameter Name Description of Function Codes Setting Range Group P7: Operation Panel and Display Accumulative running 0–65535 h time Default Property -- ● It is used to display the accumulative running time of the AC drive. After the accumulative running time reaches the value set in P8-17, the terminal with the digital output function 12 becomes ON. Function Code P7-10 P7-11 P7-12 Parameter Name Setting Range Group P7: Operation Panel and Display Product number -Software version -0: 0 decimal place Number of decimal 1: 1 decimal place places for load speed 2: 2 decimal places display 3: 3 decimal places Default Property --- ● ● 1 ☆ P7-12 is used to set the number of decimal places for load speed display. The following gives an example to explain how to calculate the load speed: Assume that P7-06 (Load speed display coefficient) is 2.000 and P7-12 is 2 (2 decimal places). When the running frequency of the AC drive is 40.00 Hz, the load speed is 40.00x 2.000 = 80.00 (display of 2 decimal places). If the AC drive is in the stop state, the load speed is the speed corresponding to the set frequency, namely, "set load speed". If the set frequency is 50.00 Hz, the load speed in the stop state is 50.00 x 2.000 = 100.00 (display of 2 decimal places). Function Code P7-13 Parameter Name Setting Range Group P7: Operation Panel and Display Accumulative power-on 0–65535 h time Default Property 0h ● It is used to display the accumulative power-on time of the AC drive since the delivery. If the time reaches the set power-on time (P8-17), the terminal with the digital output function 24 becomes ON. Function Code P7-14 Parameter Name Setting Range Group P7: Operation Panel and Display Accumulative power 0–65535 kWh consumption Default Property -- ● It is used to display the accumulative power consumption of the AC drive until now. www.ssinverter.info SSI700 User Manual Description of Function Codes Group F8: Auxiliary Functions Function Code P8-00 P8-01 P8-02 Parameter Name Setting Range Default Property JOG running frequency JOG acceleration time JOG deceleration time 0.00 Hz to maximum frequency 0.0–6500.0s 0.0–6500.0s 2.00 Hz 20.0s 20.0s ☆ ☆ ☆ These parameters are used to define the set frequency and acceleration/deceleration time of the AC drive when jogging. The startup mode is "Direct start" (P6-00 = 0) and the stop mode is "Decelerate to stop" (P6-10 = 0) during jogging. Function Code P8-03 P8-04 P8-05 P8-06 P8-07 P8-08 Parameter Name Acceleration time 2 Deceleration time 2 Acceleration time 3 Deceleration time 3 Acceleration time 4 Deceleration time 4 Setting Range Group P8: Auxiliary Functions 0.0–6500.0s 0.0–6500.0s 0.0–6500.0s 0.0–6500.0s 0.0–6500.0s 0.0–6500.0s Default Property Model ☆ ☆ ☆ ☆ ☆ ☆ dependent The SSI700 provides a total of four groups of acceleration/deceleration time, that is, the preceding three groups and the group defined by P0-17 and P0-18. Definitions of four groups are completely the same. You can switch over between the four groups of acceleration/deceleration time through different state combinations of DI terminals. For more details, see the descriptions of P4-01 to P4-05. Function Code P8-09 P8-10 P8-11 Parameter Name Jump frequency 1 Jump frequency 2 Frequency jump amplitude Setting Range 0.00 Hz to maximum frequency 0.00 Hz to maximum frequency 0.00 Hz to maximum frequency Default 0.00Hz 0.00Hz 0.00Hz If the set frequency is within the frequency jump range, the actual running frequency is the jump frequency close to the set frequency. Setting the jump frequency helps to avoid the mechanical resonance point of the load. The SSI700 supports two jump frequencies. If both are set to 0, the frequency jump function is disabled. The principle of the jump frequencies and jump amplitude is shown in the following figure. Figure 6-15 Principle of the jump frequencies and jump amplitude www.ssinverter.info SSI700 User Manual Function Code Description of Function Codes Parameter Name Setting Range Default Property 0.0s ☆ Group P8: Auxiliary Functions P8-12 Forward/Reverse rotation dead-zone time 0.0–3000.0s It is used to set the time when the output is 0 Hz at transition of the AC drive forward rotation and reverse rotation, as shown in the following figure. Figure 6-16 Forward/Reverse rotation dead-zone time Function Code P8-13 Parameter Name Reverse control Setting Range Group P8: Auxiliary Functions 0: Enabled 1: Disabled Default Property 0 ☆ It is used to set whether the AC drive allows reverse rotation. In the applications where reverse rotation is prohibited, set this parameter to 1. Function Code Parameter Name P8-14 Running mode when set frequency lower than frequency lower limit Setting Range 0: Run at frequency lower limit 1: Stop 2: Run at zero speed Default Property 0 ☆ It is used to set the AC drive running mode when the set frequency is lower than the frequency lower limit. The SSI700 provides three running modes to satisfy requirements of various applications. Function Code P8-15 Parameter Name Droop control Setting Range 0.00–10.00 Hz Default Property 0.00Hz ☆ This function is used for balancing the workload allocation when multiple motors are used to drive the same load. The output frequency of the AC drives decreases as the load increases. You can reduce the workload of the motor under load by decreasing the output frequency for this motor, implementing workload balancing between multiple motors. Function Code Parameter Name P8-16 Accumulative power-on time Setting Range threshold 0–65000 Default Property 0h ☆ www.ssinverter.info SSI700 User Manual Description of Function Codes If the accumulative power-on time (P7-13) reaches the value set in this parameter, the corresponding DO terminal becomes ON. For example, combining virtual DI/DO functions, to implement the function that the AC drive reports an alarm when the actual accumulative power-on time reaches the threshold of 100 hours, perform the setting as follows: 1) Set the accumulative power-on time threshold to 100 h: P8-16 = 100 h. Function Code P8-17 Parameter Name Setting Range Group P8: Auxiliary Functions Accumulative running threshold 0–65000 time Default Property 0h ☆ It is used to set the accumulative running time threshold of the AC drive. If the accumulative running time (P7-09) reaches the value set in this parameter, the corresponding DO terminal becomes ON. Function Code P8-18 Parameter Name Startup protection Setting Range Group P8: Auxiliary Functions 0: No 1: Yes Default Property 0 ☆ This parameter is used to set whether to enable the safety protection. If it is set to 1, the AC drive does not respond to the run command valid upon AC drive power-on (for example, an input terminal is ON before power-on). The AC drive responds only after the run command is cancelled and becomes valid again. In addition, the AC drive does not respond to the run command valid upon fault reset of the AC drive. The run protection can be disabled only after the run command is cancelled. In this way, the motor can be protected from responding to run commands upon power-on or fault reset in unexpected conditions. Function Code Parameter Name Default Property 0.00 Hz to maximum frequency 50.00 Hz ☆ 0.0%–100.0% (BRAKE control hysteresis 1) 5.0% ☆ Setting Range Group P8: Auxiliary Functions P8-19 P8-20 Frequency detection value (BRAKE control 1) Frequency detection hysteresis (BRAKE control hysteresis 1) If the running frequency is higher than the value of P8-19, the corresponding DO terminal becomes ON. If the running frequency is lower than value of P8-19, the DO terminal goes OFF These two parameters are respectively used to set the detection value of output frequency and hysteresis value upon cancellation of the output. The value of P8-20 is a percentage of the hysteresis frequency to the frequency detection value (P8-19). The BRAKE control function is shown in the following figure. www.ssinverter.info SSI700 User Manual Description of Function Codes Figure 6-17 BRAKE control level Function Code P8-21 Parameter Name Setting Range Group P8: Auxiliary Functions Detection range of 0.00–100% (maximum frequency reached frequency) Default Property 0.0% ☆ If the AC drive running frequency is within the certain range of the set frequency, the corresponding DO terminal becomes ON. This parameter is used to set the range within which the output frequency is detected to reach the set frequency. The value of this parameter is a percentage relative to the maximum frequency. The detection range of frequency reached is shown in the following figure. Figure 6-18 Detection range of frequency reached www.ssinverter.info SSI700 User Manual Function Code P8-22 Parameter Name Description of Function Codes Setting Range Group P8: Auxiliary Functions 0: Disabled Jump frequency during acceleration/deceleration 1: Enabled Default Property 0 ☆ It is used to set whether the jump frequencies are valid during acceleration/deceleration. When the jump frequencies are valid during acceleration/deceleration, and the running frequency is within the frequency jump range, the actual running frequency will jump over the set frequency jump amplitude (rise directly from the lowest jump frequency to the highest jump frequency). The following figure shows the diagram when the jump frequencies are valid during acceleration/deceleration. Figure 6-19 Diagram when the jump frequencies are valid during acceleration/deceleration Function Code P8-25 P8-26 Parameter Name Setting Range Group P8: Auxiliary Functions Frequency switchover point between 0.00 to maximum frequency acceleration time 1 and acceleration time 2 Frequency switchover point between 0.00 to maximum frequency deceleration time 1 and deceleration time 2 Default Property 0.00 Hz ☆ 0.00 Hz ☆ This function is valid when motor 1 is selected and acceleration/deceleration time switchover is not performed by means of DI terminal. It is used to select different groups of acceleration/deceleration time based on the running frequency range rather than DI terminal during the running process of the AC drive. www.ssinverter.info SSI700 User Manual Description of Function Codes Figure 6-20 Acceleration/deceleration time switchover During acceleration, if the running frequency is smaller than the value of P8-25, acceleration time 2 is selected. If the running frequency is larger than the value of P8-25, acceleration time 1 is selected. During deceleration, if the running frequency is larger than the value of P8-26, deceleration time1 is selected. If the running frequency is smaller than the value of P8-26, deceleration time 2 is selected. Function Code Parameter Name P8-27 Terminal JOG preferred Setting Range Group P8: Auxiliary Functions 0: Disabled 1: Enabled Default Property 0 ☆ It is used to set whether terminal JOG is preferred. If terminal JOG is preferred, the AC drive switches to terminal JOG running state when there is a terminal JOG command during the running process of the AC drive. Function Code Parameter Name Default Property 0.00 Hz to maximum frequency 50.00 Hz ☆ 0.0%–100.0% (BRAKE control hysteresis 2) 5.0% ☆ Setting Range Group P8: Auxiliary Functions P8-28 P8-29 Frequency detection value (BRAKE control 2) Frequency detection hysteresis (BRAKE control hysteresis 2) The frequency detection function is the same as BRAKE control 1 function. For details, refer to the descriptions of P8-19 and P8-20. www.ssinverter.info SSI700 User Manual Function Code P8-30 P8-31 P8-32 P8-33 Parameter Name Description of Function Codes Setting Range Group P8: Auxiliary Functions Any frequency reaching 0.00 Hz to maximum frequency detection value 1 Any frequency reaching 0.0%–100.0% (maximum detection amplitude 1 frequency) Any frequency reaching 0.00 Hz to maximum frequency detection value 2 Any frequency reaching 0.0%–100.0% (maximum detection amplitude 2 frequency) Default Property 50.00 Hz ☆ 0.0% ☆ 50.00 Hz ☆ 0.0% ☆ If the output frequency of the AC drive is within the positive and negative amplitudes of the any frequency reaching detection value, the corresponding DO becomes ON. The SSI700 provides two groups of any frequency reaching detection parameters, including frequency detection value and detection amplitude, as shown in the following figure. Figure 6-21 Any frequency reaching detection Function Code P8-34 P8-35 Parameter Name Setting Range Group P8: Auxiliary Functions Zero current detection 0.0%–300.0% (rated motor level current) Zero current detection 0.00–600.00s delay time Default Property 5.0% ☆ 0.10s ☆ If the output current of the AC drive is equal to or less than the zero current detection level and the duration exceeds the zero current detection delay time, the corresponding DO becomes ON. The zero current detection is shown in the following figure. www.ssinverter.info SSI700 User Manual Description of Function Codes Figure 6-22 Zero current detection Function Code Parameter Name P8-36 Output overcurrent threshold P8-37 Output overcurrent detectiondelay time Setting Range Group P8: Auxiliary Functions 0.0% (no detection) 0.1%–300.0% (rated motor current) 0.00–600.00s Default Property 200.0 % ☆ 0.00s ☆ If the output current of the AC drive is equal to or higher than the overcurrent threshold and the duration exceeds the detection delay time, the corresponding DO becomes ON. The output overcurrent detection function is shown in the following figure. Figure 6-23 Output overcurrent detection www.ssinverter.info SSI700 User Manual Function Code P8-38 P8-39 P8-40 P8-41 Description of Function Codes Parameter Name Setting Range Default Any current reaching 1 Any current reaching 1 amplitude Any current reaching 2 Any current reaching 2 amplitude 0.0%–300.0% (rated motor current) 0.0%–300.0% (rated motor current) 0.0%–300.0% (rated motor current) 0.0%–300.0% (rated motor current) 100.0% 0.0% 100.0% 0.0% If the output current of the AC drive is within the positive and negative amplitudes of any current reaching detection value, the corresponding DO becomes ON. The SSI700 provides two groups of any current reaching detection parameters, including current detection value and detection amplitudes, as shown in the following figure. Figure 6-24 Any current reaching detection Function Code Parameter Name P8-42 Timing function P8-43 Timing duration source P8-44 Timing duration Setting Range 0: Disabled 1: Enabled 0: P8-44 1: AI1 2: AI2 3: Resered(100%of analog input corresponds to the value of P8-44) 0.0–6500.0 min Default Property 0 ☆ 0 ☆ 0.0 min ☆ These parameters are used to implement the AC drive timing function. If P8-42 is set to 1, the AC drive starts to time at startup. When the set timing duration is reached, the AC drive stops automatically and meanwhile the corresponding DO becomes ON. The AC drive starts timing from 0 each time it starts up and the remaining timing duration can be queried by D0-20. The timing duration is set in P8-43 and P8-44, in unit of minute. Function Code P8-45 P8-46 Parameter Name AI1 input voltage lower limit AI1 input voltage upper limit Setting Range 0.00 V to P8-46 P8-45 to 10.00 V Default Property 3.10V 6.80 V ☆ ☆ These two parameters are used to set the limits of the input voltage to provide protection on the AC drive. When the AI1 input is larger than the value of P8-46 or smaller than the value of P8-45, the corresponding DO becomes ON, indicating that AI1 input exceeds the limit. www.ssinverter.info SSI700 User Manual Function Code Description of Function Codes Parameter Name Setting Range Default Property 75°C ☆ Group P8: Auxiliary Functions P8-47 Module temperature threshold 0–100°C When the heatsink temperature of the AC drive reaches the value of this parameter, the corresponding DO becomes ON, indicating that the module temperature reaches the threshold. Function Code P8-48 Parameter Name Cooling fan control Setting Range Default Property 0 ☆ Group P8: Auxiliary Functions 0: Fan working during running 1: Fan working continuously It is used to set the working mode of the cooling fan. If this parameter is set to 0, the fan works when the AC drive is in running state. When the AC drive stops, the cooling fan works if the heatsink temperature is higher than 40°C, and stops working if the heatsink temperature is lower than 40°C. If this parameter is set to 1, the cooling fan keeps working after power-on. Function Code P8-49 P8-50 P8-51 P8-52 Parameter Name Setting Range Group P8: Auxiliary Functions Dormant frequency (P8-51) to Wakeup frequency maximum frequency (P0-10) Wakeup delay time 0.0–6500.0s Dormant(Sleeping) 0.00 Hz to wakeup frequency frequency (P8-49) Dormant(Sleeping) 0.0–6500.0s delay time Default Property 0.00Hz ☆ 0.0s ☆ 0.00Hz ☆ 0.0s ☆ These parameters are used to implement the dormant and wakeup functions in the water supply application. When the AC drive is in running state, the AC drive enters the dormant state and stops automatically after the dormant delay time (P8-52) if the set frequency is lower than or equal to the dormant frequency (P8-51). When the AC drive is in dormant state and the current running command is effective, the AC drives starts up after the wakeup delay time (P8-50) if the set frequency is higher than or equal to the wakeup frequency (P8-49). Generally, set the wakeup frequency equal to or higher than the dormant frequency. If the wakeup frequency and dormant frequency are set to 0, the dormant and wakeup functions are disabled. When the dormant function is enabled, if the frequency source is PID, whether PID operation is performed in the dormant state is determined by 11-28. In this case, select PID operation enabled in the stop state (11-28 = 1). Function Code Parameter Name Setting Range Default Property 0.0 min ☆ Group P8: Auxiliary Functions P8-53 Current running time reached 0.0–6500.0 min If the current running time reaches the value set in this parameter, the corresponding DO becomes ON, indicating that the current running time is reached. www.ssinverter.info SSI700 User Manual Description of Function Codes Group F9: Fault and Protection Function Code P9-00 P9-01 • Parameter Name Setting Range Motor overload protection selection Motor overload protection gain 0: Disabled 1: Enabled 0.20–10.00 Default Property 1 ☆ 1.00 ☆ P9-00 = 0 The motor overload protective function is disabled. The motor is exposed to potential damage due to overheating. A thermal relay is suggested to be installed between the AC drive and the motor. • P9-00 = 1 The AC drive judges whether the motor is overloaded according to the inverse time-lag curve of the motor overload protection. The inverse time-lag curve of the motor overload protection is: 220% x P9-01 x rated motor current (if the load remains at this value for one minute, the AC drive reports motor overload fault), or 150% x P9-01 x rated motor current (if the load remains at this value for 60 minutes, the AC drive reports motor overload fault) Set P9-01 properly based on the actual overload capacity. If the value of P9-01 is set too large, damage to the motor may result because the motor overheats but the AC drive does not report the alarm. Function Code P9-02 Parameter Name Setting Range Motor overload warning coefficient 50%–100% Default Property 80% ☆ This function is used to give a warning signal to the control system via DO before motor overload protection. This parameter is used to determine the percentage, at which prewarning is performed before motor overload. The larger the value is, the less advanced the pre-warning will be. When the accumulative output current of the AC drive is greater than the value of the overload inverse time-lag curve multiplied by P9-02, the DO terminal on the AC drive allocated with function 6 (Motor overload pre-warning) becomes ON. Function Code P9-03 P9-04 Parameter Name Overvoltage stall gain Overvoltage stall protective voltage Setting Range 0 (no stall overvoltage)–100 120%–150% Default Property 0 ☆ 130% ☆ When the DC bus voltage exceeds the value of P9-04 (Overvoltage stall protective voltage) during deceleration of the AC drive, the AC drive stops deceleration and keeps the present running frequency. After the bus voltage declines, the AC drive continues to decelerate. P9-03 (Overvoltage stall gain) is used to adjust the overvoltage suppression capacity of the AC drive. The larger the value is, the greater the overvoltage suppression capacity will be. In the prerequisite of no overvoltage occurrence, set P9-03 to a small value. For small-inertia load, the value should be small. Otherwise, the system dynamic response will be slow. For large-inertia load, the value should be large. Otherwise, the suppression result will be poor and an overvoltage fault may occur. If the overvoltage stall www.ssinverter.info SSI700 User Manual Description of Function Codes gain is set to 0, the overvoltage stall function is disabled. The overvoltage stall protective voltage setting 100% corresponds to the base values in the following table: Table 6-7 Overvoltage stall protective voltage setting 100% corresponds to base values Voltage Class Single-phase 220 V Three-phase 220 V Three-phase 380 V Function Code P9-05 P9-06 Corresponding Base Value 290 V 290 V 530 V Parameter Name Overcurrent stall gain Overcurrent stall protective current P9-07 Short-circuit to ground upon power-on P9-09 Fault auto reset times P9-10 DO action during fault auto reset P9-11 Time interval of fault auto reset Setting Range 0–100 100%–200% 0: Disabled 1: Enabled 0–20 0: Not act 1: Act 0.1s–100.0s Default Property 20 150% ☆ ☆ 1 ☆ 0 ☆ 0 ☆ 1.0s ☆ When the output current exceeds the overcurrent stall protective current during acceleration/deceleration of the AC drive, the AC drive stops acceleration/deceleration and keeps the present running frequency. After the output current declines, the AC drive continues to accelerate/decelerate. P9-05 (Overcurrent stall gain) is used to adjust the overcurrent suppression capacity of the AC drive. The larger the value is, the greater the overcurrent suppression capacity will be. In the prerequisite of no overcurrent occurrence, set P9-05 to a small value. For small-inertia load, the value should be small. Otherwise, the system dynamic response will be slow. For large-inertia load, the value should be large. Otherwise, the suppression result will be poor and overcurrent fault may occur. If the overcurrent stall gain is set to 0, the overcurrent stall function is disabled. Figure 6-25 Diagram of the overcurrent stall protection function www.ssinverter.info SSI700 User Manual Function Code P9-07 Description of Function Codes Parameter Name Short-circuit to ground upon power-on Setting Range Default Property 1 ☆ 0: Disabled 1: Enabled It is used to determine whether to check the motor is short-circuited to ground at power-on of the AC drive. If this function is enabled, the AC drive's UVW will have voltage output a while after power-on. Function Code P9-09 Parameter Name Fault auto reset times Setting Range Default Property 0 ☆ 0–20 It is used to set the times of fault auto resets if this function is used. After the value is exceeded, the AC drive will remain in the fault state. Function Code P9-10 Parameter Name DO action during fault auto reset Setting Range Default Property 0 ☆ 0: Not act 1: Act It is used to decide whether the DO acts during the fault auto reset if the fault auto reset function is selected. Function Code P9-11 Parameter Name Time interval of fault auto reset Setting Range 0.1s–100.0s Default Property 1.0s ☆ It is used to set the waiting time from the alarm of the AC drive to fault auto reset. Function Code P9-12 Parameter Name Input phase loss protection/ contactor energizing protection selection Setting Range Default Property Unit's digit: Input phase loss protection Ten's digit: Contactor energizing protection 0: Disabled 1: Enabled 11 ☆ It is used to determine whether to perform input phase loss or contactor energizing protection. The SSI700 models that provide this function are listed . For every voltage class, the SSI700 AC drives of powers equal to or greater than those listed in the preceding table provide the function of input phase loss or contactor energizing protection. The SSI700 AC drives below the power listed in the table do not have the function no matter whether P9-12 is set to 0 or 1. Function Code P9-13 Parameter Name Output phase loss protection selection Setting Range Default Property 1 ☆ 0: Disabled 1: Enabled It is used to determine whether to perform output phase loss protection. Function Code P9-14 P9-15 P9-16 Parameter Name 1st fault type 2nd fault type 3rd (latest) fault type Setting Range 0~99 It is used to record the types of the most recent three faults of the AC drive. 0 indicates no fault. For possible causes and solution of each fault, refer to Chapter 8. www.ssinverter.info SSI700 User Manual Function Code Description of Function Codes Parameter Name rd P9-17 Frequency upon 3 fault P9-18 Current upon 3rd fault P9-19 Bus voltage upon 3rd fault Description It displays the frequency when the latest fault occurs. It displays the current when the latest fault occurs. It displays the bus voltage when the latest fault occurs It displays the status of all DI terminals when the latest fault occurs. The sequence is as follows: P9-20 DI status upon 3rd fault If a DI is ON, the setting is 1. If the DI is OFF, the setting is 0. The value is the equivalent decimal number converted from the DI status.. It displays the status of all output terminals when the latest fault occurs. The sequence is as follows: P9-21 Output terminal status upon 3rd fault P9-22 AC drive status upon 3rd fault P9-23 Power-on time upon 3rd fault P9-24 Running time upon 3rd fault P9-27 P9-28 P9-29 P9-30 P9-31 P9-32 P9-33 P9-34 P9-37 P9-38 P9-39 P9-40 P9-41 P9-42 P9-43 P9-44 Frequency upon 2nd fault Current upon 2nd fault Bus voltage upon 2nd fault DI status upon 2nd fault Output terminal status upon 2nd fault AC drive status upon 2rd fault Power-on time upon 2rd fault Running time upon 2rd fault Frequency upon 2nd fault Current upon 1nd fault Bus voltage upon 1nd fault DI status upon 1nd fault Output terminal status upon 1nd fault AC drive status upon 1rd fault Power-on time upon 1rd fault Running time upon 1rd fault If an output terminal is ON, the setting is 1. If the output terminal is OFF, the setting is 0. The value is the equivalent decimal number converted from the DI statuses It displays the present power-on time when the latest fault occurs. It displays the present running time when the latest fault occurs. Same as P9-17–P9-24. Same as P9-17–P9-24. www.ssinverter.info SSI700 User Manual Function Code Parameter Name P9-47 Fault protection action selection 1 P9-48 Fault protection action selection 2 P9-49 P9-50 Description of Function Codes Fault protection action selection 3 Fault protection action selection 4 Setting Range Default Group 9: Fault and Protection Unit's digit (Motor overload, OL1) 0: Coast to stop 1: Stop according to the stop mode 2: Continue to run Hundred's digit (Power output phase loss, LF) Same as unit's digit Thousand's digit (External equipment fault, EF) Same as unit's digit Ten thousand's digit (Communication fault, CE) Same as unit's digit Ten's digit (EEPROM read-write fault, EP) 0: Coast to stop 1: Stop according to the stop Mode Ten thousand's digit (Accumulative running time reached) Same as unit's digit in P9-47 Hundred's digit (Accumulative power-on time reached,UT) Same as unit's digit in P9-47 Thousand's digit (Load becoming0) 0: Coast to stop 1: Stop according to the stop mode 2: Continue to run at 7% of rated motor frequency and resume to the set frequency if the load recovers Ten thousand's digit (PID feedback lost during running, PD) Same as unit's digit in P9-47 Unit's digit (Too large speed deviation) Same as unit's digit in P9-47 Ten's digit (Motor over-speed) Same as unit's digit in P9-47 Hundred's digit (Initial position fault) Same as unit's digit in P9-47 00000 00000 00000 00000 If "Coast to stop" is selected, the AC drive displays fault and directly stops. • If "Stop according to the stop mode" is selected, the AC drive displays D** and stops according to the stop mode. After stop, the AC drive displays fault. • If "Continue to run" is selected, the AC drive continues to run and displays D**. The running frequency is set in P9-54. Function Code Parameter Name Setting Range Default 0 P9-54 Frequency selection for continuing to run upon fault 0: Current running frequency 1: Set frequency 2: Frequency upper limit 3: Frequency lower limit 4: Backup frequency upon abnormality P9-55 Backup frequency upon abnormality 0.0%–100.0% (maximum frequency) 100.0% If a fault occurs during the running of the AC drive and the handling of fault is set to "Continue to run", the AC drive displays D** and continues to run at the frequency set in P9-54. The setting of P9-55 is a percentage relative to the maximum frequency. www.ssinverter.info SSI700 User Manual Function Code P9-59 P9-60 P9-61 P9-62 Parameter Name Description of Function Codes Setting Range Group 9: Fault and Protection Action selection at 0: Invalid instantaneous power 1: Decelerate failure 2: Decelerate to stop Action pause judging voltage at instantaneous 80.0%–100.0% power failure Voltage rally judging time at instantaneous 0.00–100.00s power failure Action judging voltage at instantaneous power failure 60.0%–100.0% (standard bus voltage) Default Property 0 ☆ 90.0% ☆ 0.50s ☆ 80.0% ☆ Upon instantaneous power failure or sudden voltage dip, the DC bus voltage of the AC drive reduces. This function enables the AC drive to compensate the DC bus voltage reduction with the load feedback energy by reducing the output frequency so as to keep the AC drive running continuously. • If P9-59 = 1, upon instantaneous power failure or sudden voltage dip, the AC drive decelerates. Once the bus voltage resumes to normal, the AC drive accelerates to the set frequency. If the bus voltage remains normal for the time exceeding the value set in F9-61, it is considered that the bus voltage resumes to normal. • If P9-59 = 2, upon instantaneous power failure or sudden voltage dip, the AC drive decelerates to stop. Figure 6-26 AC drive action diagram upon instantaneous power failure www.ssinverter.info SSI700 User Manual Function Code P9-63 P9-64 P9-65 Parameter Name Description of Function Codes Setting Range Group 9: Fault and Protection Protection upon load 0: Disabled becoming 0 1: Enabled Detection level of load 0.0%–100.0% (rated motor becoming 0 current) Detection time of load 0 0.0–60.0s becoming Default Property 0 ☆ 10.0% ☆ 1.0s ☆ If protection upon load becoming 0 is enabled, when the output current of the AC drive is lower than the detection level (P9-64) and the lasting time exceeds the detection time (P9-65), the output frequency of the AC drive automatically declines to 7% of the rated frequency. During the protection, the AC drive automatically accelerates to the set frequency if the load resumes to normal. Group 10: Process Control PID Function PID control is a general process control method. By performing proportional, integral and differential operations on the difference between the feedback signal and the target signal, it adjusts the output frequency and constitutes a feedback system to stabilize the controlled counter around the target value. It is applied to process control such as flow control, pressure control and temperature control. The following figure shows the principle block diagram of PID control. Figure 6-27 Principle block diagram of PID control Function Code 10-00 10-01 Parameter Name Setting Range Group 10: Process Control PID Function 0: 10-01 1: AI1 2: AI2 PID setting source 3: Reserved 4: Pulse setting (DI5) 5: Communication setting 6: Multi-reference PID digital setting 0.0%–100.0% Default Property 0 ☆ 50.0% ☆ 10-00 is used to select the channel of target process PID setting. The PID setting is a relative value and ranges from 0.0% to 100.0%. The PID feedback is also a relative value. The purpose of PID control is to make the PID setting and PID feedback equal. www.ssinverter.info SSI700 User Manual Function Code 10-02 Description of Function Codes Parameter Name Setting Range Group 10: Process Control PID Function 0: AI1 1: AI2 2: Reserved 3: AI1 – AI2 PID feedback source 4: Pulse setting (DI5) 5: Communication setting 6: AI1 + AI2 7: MAX (|AI1|, |AI2|) 8: MIN (|AI1|, |AI2|) Default Property 0 ☆ This parameter is used to select the feedback signal channel of process PID. The PID feedback is a relative value and ranges from 0.0% to 100.0%. Function Code 10-03 • Parameter Name Setting Range Group 10: Process Control PID Function 0: Forward action 1: Reverse action PID action direction Default Property 0 ☆ 0: Forward action When the feedback value is smaller than the PID setting, the AC drive's output frequency rises. For example, the winding tension control requires forward PID action. • 1: Reverse action When the feedback value is smaller than the PID setting, the AC drive's output frequency reduces. For example, the unwinding tension control requires reverse PID action. Notes that this function is influenced by the DI function 35 "Reverse PID action direction". Function Code 10-04 Parameter Name PID setting feedback range Setting Range 0–65535 Default Property 1000 ☆ This parameter is a non-dimensional unit. It is used for PID setting display (D0-15) and PID feedback display (D0-16). Relative value 100% of PID setting feedback corresponds to the value of 10-04. If 10-04 is set to 2000 and PID setting is 100.0%, the PID setting display (D0-15) is 2000. Function Code 10-05 10-06 10-07 • Parameter Name Proportional gain Kp1 Integral time Ti1 Differential time Td1 Setting Range 0.0–100.0 0.01–10.00s 0.00–10.000 Default Property 20.0 2.00s 0.000s ☆ ☆ ☆ 10-05 (Proportional gain Kp1) It decides the regulating intensity of the PID regulator. The higher the Kp1 is, the larger the regulating intensity is. The value 100.0 indicates when the deviation between PID feedback and PID setting is 100.0%, the adjustment amplitude of the PID regulator on the output frequency reference is the maximum frequency. • 10-06 (Integral time Ti1) It decides the integral regulating intensity. The shorter the integral time is, the larger the regulating intensity is. When the deviation between PID feedback and PID setting is 100.0%, the integral regulator performs continuous adjustment for the time set in 10-06. Then the adjustment amplitude reaches the maximum frequency. www.ssinverter.info SSI700 User Manual • Description of Function Codes 10-07 (Differential time Td1) It decides the regulating intensity of the PID regulator on the deviation change. The longer the differential time is, the larger the regulating intensity is. Differential time is the time within which the feedback value change reaches 100.0%, and then the adjustment amplitude reaches the maximum frequency. Function Code 10-08 Parameter Name Setting Range Group 10: Process Control PID Function Cut-off frequency of PID 0.00 to maximum frequency reverse rotation Default Property 2.00 Hz ☆ In some situations, only when the PID output frequency is a negative value (AC drive reverse rotation), PID setting and PID feedback can be equal. However, too high reverse rotation frequency is prohibited in some applications, and 10-08 is used to determine the reverse rotation frequency upper limit. Function Code 10-09 Parameter Name Setting Range Group 10: Process Control PID Function PID deviation limit 0.0%–100.0% Default Property 0.0% ☆ If the deviation between PID feedback and PID setting is smaller than the value of 10-09, PID control stops. The small deviation between PID feedback and PID setting will make the output frequency stabilize, effective for control applications. Function Code 10-10 Parameter Name Setting Range Group 10: Process Control PID Function PID differential limit 0.00%–100.00% Default Property 0.10% ☆ It is used to set the PID differential output range. In PID control, the differential operation may easily cause system oscillation. Thus, the PID differential regulation is restricted to a small range. Function Code 10-11 Parameter Name Setting Range Group 10: Process Control PID Function PID setting change time 0.00–650.00s Default Property 0.00s ☆ The PID setting change time indicates the time required for PID setting changing from 0.0% to 100.0%. The PID setting changes linearly according to the change time, reducing the impact caused by sudden setting change on the system. Function Code 10-12 10-13 Parameter Name Setting Range Group 10: Process Control PID Function PID feedback filter time 0.00–60.00s PID output filter time 0.00–60.00s Default Property 0.00s 0.00s ☆ ☆ 10-12 is used to filter the PID feedback, helping to reduce interference on the feedback but slowing the response of the process system. 10-13 is used to filter the PID output frequency, helping to weaken sudden change of the AC drive output frequency but slowing the response of the process system. www.ssinverter.info SSI700 User Manual Function Code 10-15 10-16 10-17 10-18 10-19 10-20 Parameter Name Description of Function Codes Default Property 20.0 20.0 0.000s ☆ ☆ ☆ 0 ☆ 0.0% to 10-20 20.0% ☆ 10-19 to 100.0% 80.0% ☆ Setting Range Group 10: Process Control PID Function Proportional gain Kp2 0.0–100.0 Integral time Ti2 0.0–100.0 Differential time Td2 0.000–10.000s PID parameter switchover condition PID parameter switchover deviation 1 PID parameter switchover deviation 2 0: No switchover 1: Switchover via DI 2: Automatic switchover based on deviation In some applications, PID parameters switchover is required when one group of PID parameters cannot satisfy the requirement of the whole running process. These parameters are used for switchover between two groups of PID parameters. Regulator parameters 10-15 to 10-17 are set in the same way as 10-05 to 10-07. The switchover can be implemented either via a DI terminal or automatically implemented based on the deviation. If you select switchover via a DI terminal, the DI must be allocated with function 43 "PID parameter switchover". If the DI is OFF, group 1 (10-05 to 10-07) is selected. If the DI is ON, group 2 (10-15 to 10-17) is selected. If you select automatic switchover, when the absolute value of the deviation between PID feedback and PID setting is smaller than the value of 10-19, group1 is selected. When the absolute value of the deviation between PID feedback and PID setting is higher than the value of 10-20, group 2 is selected. When the deviation is between 10-19 and 10-20, the PID parameters are the linear interpolated value of the two groups of parameter values. Figure 6-28 PID parameters switchover Function Code 10-21 10-22 Parameter Name Setting Range Group 10: Process Control PID Function PID initial value 0.0%–100.0% PID initial value holding 0.00–650.00s time Default Property 0.0% ☆ 0.00s ☆ When the AC drive starts up, the PID starts algorithm only after the PID output is fixed to the PID initial value (10-21) and lasts the time set in 10-22. www.ssinverter.info SSI700 User Manual Description of Function Codes Figure 6-29 PID initial value function Function Code Parameter Name Maximum deviation between two PID outputs in forward direction Maximum deviation between two PID outputs in reverse direction 10-23 10-24 Setting Range Default Property 0.00%–100.00% 1.00% ☆ 0.00%–100.00% 1.00% ☆ This function is used to limit the deviation between two PID outputs (2 ms per PID output) to suppress the rapid change of PID output and stabilize the running of the AC drive. 10-23 and 10-24 respectively correspond to the maximum absolute value of the output deviation in forward direction and in reverse direction. Function Code PID integral property 10-25 • Parameter Name Setting Range Default Unit's digit (Integral separated) 0: Invalid 1: Valid Ten's digit (Whether to stop integral operation when the output reaches the limit) 0: Continue integral operation 1: Stop integral operation 00 Integral separated If it is set to valid, , the PID integral operation stops when the DI allocated with function 38 "PID integral pause" is ON In this case, only proportional and differential operations take effect. If it is set to invalid, integral separated remains invalid no matter whether the DI allocated with function 38 "PID integral pause" is ON or not. • Whether to stop integral operation when the output reaches the limit If "Stop integral operation" is selected, the PID integral operation stops, which may help to reduce the PID overshoot. Function Code Parameter Name 10-26 PID operation at stop Setting Range 0: No PID operation at stop 1: PID operation at stop Default Property 0 ☆ It is used to select whether to continue PID operation in the state of stop. Generally, the PID operation stops when the AC drive stops. Function Code 10-28 10-27 Parameter Name Detection value of PID feedback loss Detection time of PID feedback loss Setting Range 0.0%: Not judging feedback loss 0.1%–100.0% 0.0–20.0s Default 0.0% 0.0s www.ssinverter.info SSI700 User Manual Description of Function Codes These parameters are used to judge whether PID feedback is lost. If the PID feedback is smaller than the value of 10-28 and the lasting time exceeds the value of 10-27, the AC drive reports fault PD and acts according to the selected fault protection action. Group 11: Swing Frequency, Fixed Length and Count The swing frequency function is applied to the textile and chemical fiber fields and the applications where traversing and winding functions are required. The swing frequency function indicates that the output frequency of the AC drive swings up and down with the set frequency as the center. The trace of running frequency at the time axis is shown in the following figure. The swing amplitude is set in 11-00 and 11-01. When 11-01 is set to 0, the swing amplitude is 0 and the swing frequency does not take effect. Figure 6-30 Swing frequency control Function Code 11-00 Setting Range Default Property 0: Relative to the central frequency 1: Relative to the maximum frequency 0 ☆ Parameter Name Swing frequency setting mode This parameter is used to select the base value of the swing amplitude. • 0: Relative to the central frequency (P0-07 frequency source selection) It is variable swing amplitude system. The swing amplitude varies with the central frequency (set frequency). • 1: Relative to the maximum frequency (P0-10 maximum output frequency) It is fixed swing amplitude system. The swing amplitude is fixed. Function Code Parameter Name Setting Range Default Property 11-01 Swing frequency amplitude 0.0%–100.0% 0.0% ☆ 11-02 Jump frequency amplitude 0.0%–50.0% 0.0% ☆ This parameter is used to determine the swing amplitude and jump frequency amplitude. The swing frequency is limited by the frequency upper limit and frequency lower limit. www.ssinverter.info SSI700 User Manual Description of Function Codes • If relative to the central frequency (11-00 = 0), the actual swing amplitude AW is the calculation result of P0-07 (Frequency source selection) multiplied by 11-01. • If relative to the maximum frequency (11-00 = 1), the actual swing amplitude AW is the calculation result of P0-10 (Maximum frequency) multiplied by 11-01. Jump frequency = Swing amplitude AW x 11-02 (Jump frequency amplitude). • If relative to the central frequency (11-00 = 0), the jump frequency is a variable value. • If relative to the maximum frequency (11-00 = 1), the jump frequency is a fixed value. The swing frequency is limited by the frequency upper limit and frequency lower limit. Function Code 11-03 11-04 Parameter Name Setting Range Swing frequency cycle Triangular wave rising timecoefficient 0.0–3000.0s 0.0%–100.0% Default Property 10.0s 50.0% ☆ ☆ 11-03 specifies the time of a complete swing frequency cycle. 11-04 specifies the time percentage of triangular wave rising time to 11-03 (Swing frequency cycle). • Triangular wave rising time = 11-03 (Swing frequency cycle) x 11-04 (Triangular wave rising time coefficient, unit: s) • Triangular wave falling time = 11-03 (Swing frequency cycle) x (1 – 11-04 Triangular wave rising time coefficient ,unit: s) Function Code 11-05 11-06 11-07 Parameter Name Setting Range Set length Actual length Number of pulses per meter 0–65535 m 0–65535 m 0.1–6553.5 Default Property 1000m 0m 100.0 ☆ ☆ ☆ The preceding parameters are used for fixed length control. The length information is collected by DI terminals. 11-06 (Actual length) is calculated by dividing the number of pulses collected by the DI terminal by 11-07 (Number of pulses each meter). When the actual length 11-06 exceeds the set length in 11-05, the DO terminal allocated with function 10 (Length reached) becomes ON. During the fixed length control, the length reset operation can be performed via the DI terminal allocated with function 28. For details, see the descriptions of P4-00 to P4-09. Allocate corresponding DI terminal with function 27 (Length count input) in applications. If the pulse frequency is high, DI5 must be used. Function Code 11-08 11-09 Parameter Name Set count value Designated count value Setting Range 1–65535 1–65535 Default Property 1000 1000 ☆ ☆ The count value needs to be collected by DI terminal. Allocate the corresponding DI terminal with function 25 (Counter input) in applications. If the pulse frequency is high, DI5 must be used. When the count value reaches the set count value (11-08), the DO terminal allocated with function 8 (Set count value reached) becomes ON. Then the counter stops counting. When the counting value reaches the designated counting value (11-09), the DO terminal allocated with function 9 (Designated count value reached) becomes ON. Then the counter continues to count until the set count value is reached. 11-09 should be equal to or smaller than 11-08. www.ssinverter.info SSI700 User Manual Description of Function Codes Figure 6-31 Reaching the set count value and designated count value Group 12: Multi-Reference and Simple PLC Function The SSI700 multi-reference has many functions. Besides multi-speed, it can be used as the setting source of the V/F separated voltage source and setting source of process PID. In addition, the multi-reference is relative value. The simple PLC function is different from the SSI700 user programmable function. Simple PLC can only complete simple combination of multi-reference, while the user programmable function is more practical. Function Code 12-00 12-01 12-02 12-03 12-04 12-05 12-06 12-07 12-08 12-09 12-10 12-11 12-12 12-13 12-14 12-15 Parameter Name Setting Range Group 12: Multi-Reference and Simple PLC Function Reference 0 -100.0%~100.0% Reference 1 -100.0%~100.0% Reference 2 -100.0%~100.0% Reference 3 -100.0%~100.0% Reference 4 -100.0%~100.0% Reference 5 -100.0%~100.0% Reference 6 -100.0%~100.0% Reference 7 -100.0%~100.0% Reference 8 -100.0%~100.0% Reference 9 -100.0%~100.0% Reference 10 -100.0%~100.0% Reference 11 -100.0%~100.0% Reference 12 -100.0%~100.0% Reference 13 -100.0%~100.0% Reference 14 -100.0%~100.0% Reference 15 -100.0%~100.0% Default Property 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% ☆ ☆ ☆ ☆ ☆ ☆ ☆ ☆ ☆ ☆ ☆ ☆ ☆ ☆ ☆ ☆ Multi-reference can be the setting source of frequency, V/F separated voltage and process PID. The multi-reference is relative value and ranges from -100.0% to 100.0%. As frequency source, it is a percentage relative to the maximum frequency. As V/F separated voltage source, it is a percentage relative to the rated motor voltage. As process PID setting source, it does not require conversion. Multi-reference can be switched over based on different states of DI terminals. For details, see the descriptions of group P4. Function Code 12-16 Parameter Name Setting Range Group 12: Multi-Reference and Simple PLC Function 0: Stop after the AC drive runs one cycle 1: Keep final values after the AC drive Simple PLC runs one cycle running mode 2: Repeat after the AC drive runs one cycle Default Property 0 ☆ www.ssinverter.info SSI700 User Manual • Description of Function Codes 0: Stop after the AC drive runs one cycle The AC drive stops after running one cycle, and will not start up until receiving another command. • 1: Keep final values after the AC drive runs one cycle The AC drive keeps the final running frequency and direction after running one cycle. • 2: Repeat after the AC drive runs one cycle The AC drive automatically starts another cycle after running one cycle, and will not stop until receiving the stop command. Simple PLC can be either the frequency source or V/F separated voltage source. When simple PLC is used as the frequency source, whether parameter values of 12-00 to 12-15 are positive or negative determines the running direction. If the parameter values are negative, it indicates that the AC drive runs in reverse direction. Figure 6-32 Simple PLC when used as frequency source Function Code 12-17 Parameter Name Setting Range Group 12: Multi-Reference and Simple PLC Function Unit's digit (Retentive upon power failure) 0: No Simple PLC retentive 1: Yes selection Ten's digit (Retentive upon stop) 0: No 1: Yes Default Property 00 ☆ www.ssinverter.info SSI700 User Manual Description of Function Codes PLC retentive upon power failure indicates that the AC drive memorizes the PLC running moment and running frequency before power failure and will continue to run from the memorized moment after it is powered on again. If the unit's digit is set to 0, the AC drive restarts the PLC process after it is powered on again. PLC retentive upon stop indicates that the AC drive records the PLC running moment and running frequency upon stop and will continue to run from the recorded moment after it starts up again. If the ten's digit is set to 0, the AC drive restarts the PLC process after it starts up again. Function Code 12-18 Parameter Name Setting Range Group 12: Multi-Reference and Simple PLC Function Running time of simple PLC reference 0 0.0–6553.5s (h) Default 0.0s(h) 12-19 Acceleration/deceleration time of simple PLC reference 0 0–3 12-20 Running time of simple PLC reference 1 0.0–6553.5s (h) 12-21 Acceleration/deceleration time of simple PLC reference 1 0–3 12-22 Running time of simple PLC reference 2 0.0–6553.5s (h) 12-23 Acceleration/deceleration time of simple PLC reference 2 0–3 12-24 Running time of simple PLC reference 3 0.0–6553.5s (h) 12-25 Acceleration/deceleration time of simple PLC reference 3 0–3 12-26 Running time of simple PLC reference 4 0.0–6553.5s (h) 12-27 Acceleration/deceleration time of simple PLC reference 4 0–3 12-28 Running time of simple PLC reference 5 0.0–6553.5s (h) 12-29 Acceleration/deceleration time of simple PLC reference 5 0–3 12-30 Running time of simple PLC reference 6 0.0–6553.5s (h) 12-31 Acceleration/deceleration time of simple PLC reference 6 0–3 12-32 Running time of simple PLC reference 7 0.0–6553.5s (h) 12-33 Acceleration/deceleration time of simple PLC reference 7 0–3 12-34 Running time of simple PLC reference8 0.0–6553.5s (h) 12-35 Acceleration/deceleration time of simple PLC reference 8 0–3 12-36 Running time of simple PLC reference 9 0.0–6553.5s (h) 12-37 Acceleration/deceleration time of simple PLC reference 9 0–3 12-38 Running time of simple PLC reference 10 0.0–6553.5s (h) 12-39 Acceleration/deceleration time of simple PLC reference 10 0–3 12-40 Running time of simple PLC reference 11 0.0–6553.5s (h) 12-41 Acceleration/deceleration time of simple PLC reference 11 0–3 12-42 Running time of simple PLC reference 12 0.0–6553.5s (h) 12-43 Acceleration/deceleration time of simple PLC reference 12 0–3 12-44 Running time of simple PLC reference 13 0.0–6553.5s (h) 12-45 Acceleration/deceleration time of simple PLC reference 13 0–3 12-46 Running time of simple PLC reference 14 0.0–6553.5s (h) 12-47 Acceleration/deceleration time of simple PLC reference 14 0–3 12-48 Running time of simple PLC reference 15 0.0–6553.5s (h) 12-49 Acceleration/deceleration time of simple PLC reference 15 0–3 0 12-50 Time unit of simple PLC running 0: s (second)1:h(hour) 0 0 0.0s(h) 0 0.0s(h) 0 0.0s(h) 0 0.0s(h) 0 0.0s(h) 0 0.0s(h) 0 0.0s(h) 0 0.0s(h) 0 0.0s(h) 0 0.0s(h) 0 0.0s(h) 0 0.0s(h) 0 0.0s(h) 0 0.0s(h) 0 0.0s(h) www.ssinverter.info SSI700 User Manual Function Code 12-51 Description of Function Codes Parameter Name Setting Range Default Property 0 ☆ Group 12: Multi-Reference and Simple PLC Function 0: Set by 12-00 1: AI1 2: AI2 3: Reserved Reference 0 source 4: Pulse setting 5: PID 6: Set by preset frequency (P008), modified via terminal UP/ DOWN It determines the setting channel of reference 0. You can perform convenient switchover between the setting channels. When multi-reference or simple PLC is used as frequency source, the switchover between two frequency sources can be realized easily. Group 13: Communication Parameters Function Code Parameter Name 13-00 Data format 13-01 Baud rate 13-02 Local address 13-03 Response delay Communication timeout 13-04 13-05 Modbus protocol selection 13-06 Communication reading current resolution Default Setting Range 0: No check, data format <8,N,2> 1: Even parity check, data format <8,E,1> 2: Odd Parity check, data format <8,O,1> 3: No check, data format <8,N,1> Valid for Modbus Unit's digit (Modbus baud rate) 0: 300 BPs 1: 600 BPs 2: 1200 BPs 3: 2400 BPs 4: 4800 BPs 5: 9600 BPs 6: 19200 BPs 7: 38400 BPs 8: 57600 BPs 9: 115200 BPs 0: Broadcast address 1~247 Valid for Modbus 0–20 ms Valid for Modbus 0.0s (invalid) 0.1–60.0s Valid for Modbus Unit's digit: Modbus protocol 0: Non-standard Modbus protocol 1: Standard Modbus protocol 0: 0.01A 1: 0.1A 0 6005 1 2 ms 0.0s 30 0 Group 16: User Password Function Code 16-00 Parameter Name User password Setting Range Group 16: Function Code Management 0–65535 Default Property 0 ☆ If it is set to any non-zero number, the password protection function is enabled. After a password has been set and taken effect, you must enter the correct password in order to enter the menu. If the entered password is incorrect you cannot view or modify parameters. www.ssinverter.info SSI700 User Manual Description of Function Codes If 16-00 is set to 00000, the previously set user password is cleared, and the password protection function is disabled. Function Code 16-01 • Parameter Name Setting Range Group 16: Function Code Management 0: No operation 01: Restore factory settings except motor parameters 02: Clear records Restore default settings 04: Restore user backup parameters 501: Back up current user parameters Default Property 0 ★ 1: Restore default settings except motor parameters If 16-01 is set to 1, most function codes are restored to the default settings except motor parameters, frequency reference resolution (P0-22), fault records, accumulative running time (P7-09), accumulative power-on time (P7-13) and accumulative power consumption (P7-14). • 2: Clear records If 16-01 is set to 2, the fault records, accumulative running time (P7-09), accumulative power-on time (P7-13) and accumulative power consumption (P7-14) are cleared. • 501: Back up current user parameters If 16-01 is set to 501, the current parameter settings are backed up, helping you to restore the setting if incorrect parameter setting is performed. • 4: Restore user backup parameters If 16-01 is set to 4, the previous backup user parameters are restored. Group 17: Torque Control and Restricting Parameters Function Code 17-00 Parameter Name Setting Range Group 17: Torque Control and Restricting Parameters Speed/Torque control 0: Speed control selection 1: Torque control Default Property 0 ★ It is used to select the AC drive's control mode: speed control or torque control. The SSI700 provides DI terminals with two torque related functions, function 29 (Torque control prohibited) and function 46 (Speed control/Torque control switchover). The two DI terminals need to be used together with 17-00 to implement speed control/torque control switchover. If the DI terminal allocated with function 46 (Speed control/Torque control switchover) is OFF, the control mode is determined by 17-00. If the DI terminal allocated with function 46 is ON, the control mode is reverse to the value of 17-00. However, if the DI terminal with function 29 (Torque control prohibited) is ON, the AC drive is fixed to run in the speed control mode. www.ssinverter.info SSI700 User Manual Function Code 17-01 17-03 Parameter Name Description of Function Codes Setting Range Group 17: Torque Control and Restricting Parameters 0: Digital setting (17-03) 1: AI1 2: AI2 3: Reserved 4: Pulse setting (DI5) Torque setting source in 5: Communication setting torque control 6: MIN (AI1, AI2) 7: MAX (AI1, AI2) Full range of values 1–7 corresponds to the digital setting of 17-03. Torque digital setting in -200.0%–200.0% torque control Default Property 0 ★ 150.0 % ☆ 17-01 is used to set the torque setting source. There are a total of eight torque setting sources. The torque setting is a relative value. 100.0% corresponds to the AC drive's rated torque. The setting range is -200.0% to 200.0%, indicating the AC drive's maximum torque is twice of the AC drive's rated torque. If the torque setting is positive, the AC drive rotates in forward direction. If the torque setting is negative, the AC drive rotates in reverse direction. • 0: Digital setting (17-03) The target torque directly uses the value set in 17-03. • 1: AI1 • 2: AI2 The target torque is decided by analog input. The SSI900 control board provides two AI terminals (AI1, AI2). AI1 is 0–10 V voltage input, AI2 is 0–10 V voltage input or 4–20 mA current input decided by jumper J8 on the control board is -10 V to +10 V voltage input. The SSI700 provides five curves indicating the mapping relationship between the input voltage of AI1, AI2 and the target frequency, three of which are linear (pointpoint) correspondence and two of which are four-point correspondence curves. You can set the curves by using function codes P4-13 to P4-27 and select curves for AI1, AI2 . When AI is used as frequency setting source, the corresponding value 100% of voltage/ current input corresponds to the value of 17-03. • 4: Pulse setting (DI5) The target torque is set by DI5 (high-speed pulse). The pulse setting signal specification is 9–30 V (voltage range) and 0–100 kHz (frequency range). The pulse can only be input via DI5. The relationship (which is a two-point line) between DI5 input pulse frequency and the corresponding value is set in P4-28 to P4-31. The corresponding value 100.0% of pulse input corresponds to the value of 17-03. • 5: Communication setting The target torque is set by means of communication. If the AC drive is a slave in point-point communication and receives data as torque source, data transmitted by the master is used as the setting value. For details, see the description of group 13. In other conditions, data is given by host computer through the communication address 0x1000. The data format is -100.00% to 100.00%. 100% corresponds to the value of 17-03. www.ssinverter.info SSI700 User Manual Description of Function Codes The SSI700 provides four communication and you can select one based on actual requirements. Function Code 17-05 17-06 Parameter Name Setting Range Group 17: Torque Control and Restricting Parameters Forward maximum 0.00 Hz to maximum frequency frequency in torque (P0-10) control Reverse maximum 0.00 Hz to maximum frequency frequency in torque (P0-10) control Default Property 50.00 Hz ☆ 50.00 Hz ☆ two parameters are used to set the maximum frequency in forward or reverse rotation in torque control mode. In torque control, if the load torque is smaller than the motor output torque, the motor's rotational speed will rise continuously. To avoid runaway of the mechanical system, the motor maximum rotating speed must be limited in torque control. You can implement continuous change of the maximum frequency in torque control dynamically by controlling the frequency upper limit. Function Code 17-07 17-08 Parameter Name Setting Range Group 17: Torque Control and Restricting Parameters Acceleration time in 0.00–65000s torque control Deceleration time in 0.00–65000s torque control Default Property 0.00s ☆ 0.00s ☆ In torque control, the difference between the motor output torque and the load torque determines the speed change rate of the motor and load. The motor rotational speed may change quickly and this will result in noise or too large mechanical stress. The setting of acceleration/deceleration time in torque control makes the motor rotational speed change softly. However, in applications requiring rapid torque response, set the acceleration/ deceleration time in torque control to 0.00s. For example, two AC drives are connected to drive the same load. To balance the load allocation, set one AC drive as master in speed control and the other as slave in torque control. The slave receives the master's output torque as the torque command and must follow the master rapidly. In this case, the acceleration/deceleration time of the slave in torque control is set to 0.0s. www.ssinverter.info EMC SSI700 User Manual EMC Chapter 7 EMC 7.1 Definition of Terms 1) EMC Electromagnetic compatibility (EMC) describes the ability of electronic and electrical devices or systems to work properly in the electromagnetic environment and not to generate electromagnetic interference that influences other local devices or systems. In other words, EMC includes two aspects: The electromagnetic interference generated by a device or system must be restricted within a certain limit; the device or system must have sufficient immunity to the electromagnetic interference in the environment. 2) First environment Environment that includes domestic premises, it also includes establishments directly connected without intermediate transformers to a low-voltage power supply network which supplies buildings used for domestic purposes 3) Second environment Environment that includes all establishments other than those directly connected to a lowvoltage power supply network which supplies buildings used for domestic purposes 4) Category C1 AC drive Power Drive System (PDS) of rated voltage less than 1000 V, intended for use in the first environment 5) Category C2 AC drive PDS of rated voltage less than 1000 V, which is neither a plug in device nor a movable device and, when used in the first environment, is intended to be installed and commissioned only by a professional 6) Category C3 AC drive PDS of rated voltage less than 1000 V, intended for use in the second environment and not intended for use in the first environment 7) Category C4 AC drive PDS of rated voltage equal to or above 1000 V, or rated current equal to or above 400 A, or intended for use in complex systems in the second environment 7.2 Introduction to EMC Standard 7.2.1 EMC Standard The SSI700 series AC drive satisfies the requirements of standard EN 61800-3: 2004 Category C2. The AC drives are applied to both the first environment and the second environment. 7.2.2 Installation Environment The system manufacturer using the AC drive is responsible for compliance of the system with the European EMC directive. Based on the application of the system, the integrator must ensure that the system complies with standard EN 61800-3: 2004 Category C2, C3 or C4. Warning If applied in the first environment, the AC drive may generate radio interference. Besides the CE compliance described in this chapter, users must take measures to avoid such interference, if necessary. www.ssinverter.info SSI700 User Manual EMC 7.3 Selection of Peripheral EMC Devices 7.3.1 Installation of EMC Input Filter on Power Input Side An EMC filter installed between the AC drive and the power supply can not only restrict the interference of electromagnetic noise in the surrounding environment on the AC drive, but also prevents the interference from the AC drive on the surrounding equipment. The SSI700 series AC drive satisfies the requirements of category C2 only with an EMC filter installed on the power input side. The installation precautions are as follows: • Strictly comply with the ratings when using the EMC filter. The EMC filter is category I electric apparatus, and therefore, the metal housing ground of the filter should be in good contact with the metal ground of the installation cabinet on a large area, and requires good conductive continuity. Otherwise, it will result in electric shock or poor EMC effect. • The ground of the EMC filter and the PE conductor of the AC drive must be tied to the same common ground. Otherwise, the EMC effect will be affected seriously. • The EMC filter should be installed as closely as possible to the power input side of the AC drive. The following table lists the recommended manufacturers and models of EMC filters for the SSI700 series AC drive. Select a proper one based on actual requirements. 7.3.2 Installation of AC Input Reactor on Power Input Side An AC input reactor is installed to eliminate the harmonics of the input current. As an optional device, the reactor can be installed externally to meet strict requirements of an application environment for harmonics. The following table lists the recommended manufacturers and models of input reactors. 7.3.3 Installation of AC Output Reactor on Power Output Side Whether to install an AC output reactor on the power output side is dependent on the actual situation. The cable connecting the AC drive and the motor should not be too long; capacitance enlarges when an over-long cable is used and thus high-harmonics current may be easily generated. If the length of the output cable is equal to or greater than the value in the following table, install an AC output reactor on the power output side of the AC drive. Table 7-1 Cable length threshold when an AC output reactor is installed AC Drive Power (kW) ≥4KW Rated Voltage (V) 200~500V Cable Length Threshold (m) 50M Table 7-2 Recommended manufacturers and models of EMC filters & AC Input Reactor & AC Output Reactor AC Drive Model Rated Input Current SSI707G43A SSI715G43A SSI722G43A 3.4A 5A 5.8A AC Input Filter Model AC Input Reactor Model Three-phase 380~440V 50/60HZ NFI-005 ACL-0005 NFI-005 ACL-0007 NFI-010 ACL-0007 Rated Output Current AC Output Reactor Model 2.1A 3.8A 5.1A OCL-0005 OCL-0005 OCL-0007 www.ssinverter.info SSI700 User Manual EMC 7.4 Shielded Cable 7.4.1 Requirements for Shielded Cable The shielded cable must be used to satisfy the EMC requirements of CE marking. Shielded cables are classified into three-conductor cable and four-conductor cable. If conductivity of the cable shield is not sufficient, add an independent PE cable, or use a four-conductor cable, of which one phase conductor is PE cable. The three-conductor cable and four-conductor cable are shown in the following figure. To suppress emission and conduction of the radio frequency interference effectively, the shield of the shielded cable is cooper braid. The braided density of the cooper braid should be greater than 90% to enhance the shielding efficiency and conductivity, as shown in the following figure. The following figure shows the grounding method of the shielded cable. Figure 7-1 Grounding of the shielded cable The installation precautions are as follows: • Symmetrical shielded cable is recommended. The four-conductor shielded cable can also be used as an input cable. • The motor cable and PE shielded conducting wire (twisted shielded) should be as short as possible to reduce electromagnetic radiation and external stray current and capacitive current of the cable. If the motor cable is over 100 meters long, an output filter or reactor is required. • It is recommended that all control cables be shielded. • It is recommended that a shielded cable be used as the output power cable of the AC drive; the cable shield must be well grounded. For devices suffering from interference, shielded twisted pair (STP) cable is recommended as the lead wire and the cable shield must be well grounded www.ssinverter.info SSI700 User Manual EMC 7.4.2 Cabling Requirements 1) The motor cables must be laid far away from other cables. The motor cables of several AC drives can be laid side by side. 2) It is recommended that the motor cables, power input cables and control cables be laid in different ducts. To avoid electromagnetic interference caused by rapid change of the output voltage of the AC drive, the motor cables and other cables must not be laid side by side for a long distance. 3) If the control cable must run across the power cable, make sure they are arranged at an angle of close to 90°. Other cables must not run across the AC drive. 4) The power input and output cables of the AC drive and weak-current signal cables (such as control cable) should be laid vertically (if possible) rather than in parallel. 5) The cable ducts must be in good connection and well grounded. Aluminium ducts can be used to improve electric potential. 6) The filter, AC drive and motor should be connected to the system (machinery or appliance) properly, with spraying protection at the installation part and conductive metal in full contact. Figure 7-2 Cabling diagram www.ssinverter.info SSI700 User Manual EMC 7.5 Solutions to Common EMC Interference Problems The AC drive generates very strong interference. Although EMC measures are taken, the interference may still exist due to improper cabling or grounding during use. When the AC drive interferes with other devices, adopt the following solutions. Interference Type Leakage protection switch tripping AC drive interference during running Communication interference I/O interference Solution • Connect the motor housing to the PE of the AC drive. • Connect the PE of the AC drive to the PE of the mains power supply. • Add a safety capacitor to the power input cable. • Add magnetic rings to the input drive cable. • Connect the motor housing to the PE of the AC drive. • Connect the PE of the AC drive to the PE of the mains voltage. • Add a safety capacitor to the power input cable and wind the cable with magnetic rings. • Add a safety capacitor to the interfered signal port or wind the signal cable with magnetic rings. • Connect the equipment to the common ground. • Connect the motor housing to the PE of the AC drive. • Connect the PE of the AC drive to the PE of the mains voltage. • Add a safety capacitor to the power input cable and wind the cable with magnetic rings. • Add a matching resistor between the communication cable source and the load side. • Add a common grounding cable besides the communication cable. • Use a shielded cable as the communication cable and connect the cable shield to the common grounding point. • Enlarge the capacitance at the low-speed DI. A maximum of 0.11uF capacitance is suggested. • Enlarge the capacitance at the AI. A maximum of 0.22 uF is Suggested. www.ssinverter.info Selection and Dimensions SSI700 User Manual Selection and Dimensions Chapter 8 Selection and Dimensions 8.1 Electrical Specifications of the SSI700 Table 8-1 Models and technical data of the SSI700 AC Drive Model Power Capacity (kVA) SSI704G23A SSI707G23A SSI715G23A 0.7 1.5 3 SSI707G43A SSI715G43A SSI722G43A 1.5 3 4 Rated Rated Adaptable Input Output Motor Current Current (KW, HP) Three-phase 220V 50/60HZ 3.4A 2.1A 0.4KW 0.5HP 5A 3.8A 0.75 KW 1 HP 5.8A 5.1A 1.5 KW 2 HP Three-phase 380V 50/60HZ 3.4A 2.1A 0.75 KW 1 HP 5A 3.8A 1.5 KW 2 HP 5.8A 5.1A 2.2 KW 3 HP Thermal Power Consumption (kW) 0.027 0.050 0.066 0.027 0.050 0.066 8.2 Physical Appearance and Overall Dimensions of the SSI700 Figure 8-1 Physical appearance and overall dimensions of the SSI700 (plastic housing) www.ssinverter.info SSI700 User Manual Selection and Dimensions 8.3 Physical Dimensions of External Operation Panel Figure 8-3 Physical dimensions of external operation panel www.ssinverter.info SSI700 User Manual Selection and Dimensions 8.4 Selection of Braking Unit and Braking Resistor 8.4.1 Physical Dimensions of External Braking Resistor The motor and load's regenerative energy is almost completely consumed on the braking resistor when braking. According to the formula U x U/R = Pb: • U refers to the braking voltage at system stable braking. Different systems select different braking voltages. The 380 VAC system usually selects 700 V braking voltage. • Pb refers to the braking power. 8.3.2 Selection of Power of Braking Resistor In theory, the power of the braking resistor is consistent with the braking power. But in consideration that the de-rating is 70%, you can calculate the power of the braking resistor according to the formula 0.7 x Pr = Pb x D. • Pr refers to the power of resistor. • D refers to the braking frequency (percentage of the regenerative process to the whole working process) Application Elevator Winding and unwinding Centrifuge Occasional braking load General application Braking Frequency 20%–30% 20%–30% 50%–60% 5% 10% Table 8-4 below provides data for reference. You can select different resistance and power based on actual needs. However, the resistance must not be lower than the recommended value. The power may be higher than the recommended value. The braking resistor model is dependent on the generation power of the motor in the actual system and is also related to the system inertia, deceleration time and potential energy load. For systems with high inertia, and/or rapid deceleration times, or frequent braking sequences, the braking resistor with higher power and lower resistance value should be selected. Table 5 Recommended values of braking resistor AC Drive Model Recommended Power SSI704G23A SSI707G23A SSI715G23A SSI707G43A SSI715G43A SSI722G43A 80W 80W 300W 80W 300W 300W Recommended Resistance Braking Unit Remark ≥ 200 Ω ≥ 200 Ω ≥ 100 Ω ≥ 750 Ω ≥ 400 Ω ≥ 250 Ω Built-in (standard) No special description www.ssinverter.info Maintenance and Troubleshooting SSI700 User Manual Maintenance and Troubleshooting Chapter 9 Maintenance and Troubleshooting 9.1 Routine Repair and Maintenance of the SSI700 9.1.1 Routine Maintenance The influence of the ambient temperature, humidity, dust and vibration will cause the aging of the devices in the AC drive, which may cause potential faults or reduce the service life of the AC drive. Therefore, it is necessary to carry out routine and periodic maintenance. Routine maintenance involves checking: • Whether the motor sounds abnormally during running • Whether the motor vibrates excessively during running • Whether the installation environment of the AC drive changes. • Whether the AC drive's cooling fan works normally • Whether the AC drive overheats Routine cleaning involves: • Keep the AC drive clean all the time. • Remove the dust, especially metal powder on the surface of the AC drive, to prevent the dust from entering the AC drive. • Clear the oil stain on the cooling fan of the AC drive. 9.1.2 Periodic Inspection Perform periodic inspection in places where inspection is difficult. Periodic inspection involves: Check and clean the air duct periodically. Check whether the screws become loose. Check whether the AC drive is corroded. Check whether the wiring terminals show signs of arcing; Main circuit insulation test Prompt Before measuring the insulating resistance with megameter (500 VDC megameter recommended), disconnect the main circuit from the AC drive. Do not use the insulating resistance meter to test the insulation of the control circuit. The high voltage test need not be performed again because it has been completed before delivery. 9.1.3 Replacement of Vulnerable Components The vulnerable components of the AC drive are cooling fan and filter electrolytic capacitor. Their service life is related to the operating environment and maintenance status. Generally, the service life is shown as follows: Component Fan Service Life Possible Damage Reason 2 to 3 years • Bearing worn • Blade aging Judging Criteria • Whether there is crack on the blade • Whether there is abnormal vibration noise upon startup www.ssinverter.info SSI700 User Manual Component Service Life Electrolytic capacitor 4 to 5 years Maintenance and Troubleshooting Possible Damage Reason • Input power supply in poor quality • High ambient temperature • Frequent load jumping • Electrolytic aging Judging Criteria • Whether there is liquid leakage. • Whether the safe valve has projected. • Measure the static capacitance. • Measure the insulating resistance. 9.1.4 Storage of the AC Drive For storage of the AC drive, pay attention to the following two aspects: 1) Pack the AC drive with the original packing box provided by SSINVERTER. 2) Long-term storage degrades the electrolytic capacitor. Thus, the AC drive must be energized once every 2 years, each time lasting at least 5 hours. The input voltage must be increased slowly to the rated value with the regulator. 9.2 Warranty Agreement 1) Free warranty only applies to the AC drive itself. 2) SSINVERTER will provide 18-month warranty (starting from the leave-factory date as indicated on the barcode) for the failure or damage under normal use conditions. If the equipment has been used for over 18 months, reasonable repair expenses will be charged. 3) Reasonable repair expenses will be charged for the damages due to the following causes: • Improper operation without following the instructions • Fire, flood or abnormal voltage. • Using the AC drive for non-recommended function 4) The maintenance fee is charged according to SSINVERTER'S uniform standard. If there is an agreement, the agreement prevails. 9.3 Faults and Solutions The SSI700 provides a total of 24 pieces of fault information and protective functions. After a fault occurs, the AC drive implements the protection function, and displays the fault code on the operation panel (if the operation panel is available). Before contacting SSINVERTER for technical support, you can first determine the fault type, analyze the causes, and perform troubleshooting according to the following tables. If the fault cannot be rectified, contact the agent or SSINVERTER. EH is the AC drive hardware overcurrent or overvoltage signal. In most situations, hardware overvoltage fault causes EH. Figure 9-1 Solutions to the faults of the SSI900 Fault Name Inverter unit protection Display SC Possible Causes 1: The output circuit is grounded or short circuited. 2: The connecting cable of the motor is too long. 3: The module overheats. 4: The internal connections become loose. 5:The main control board is faulty. 6: The drive board is faulty. 7: The inverter module is faulty. Solutions 1: Eliminate external faults. 2: Install a reactor or an output filter. 3: Check the air filter and the cooling fan. 4: Connect all cables properly. 5: Contact the agent or Ssinverter. www.ssinverter.info SSI700 User Manual Fault Name Overcurrent during acceleration Overcurrent during deceleration Overcurrent at constant speed Display OCA OCD OCN Maintenance and Troubleshooting Possible Causes 1: The output circuit is grounded or short circuited. 2: Motor auto-tuning is not performed. 3: The acceleration time is too short. 4: Manual torque boost or V/F curve is not appropriate. 5: The voltage is too low. 6: The startup operation is performed on the rotating motor. 7: A sudden load is added during acceleration. 8: The AC drive model is of too small power class. 1: The output circuit is grounded or short circuited. 2: Motor auto-tuning is not performed. 3: The deceleration time is too short. 4: The voltage is too low. 5: A sudden load is added during deceleration. 6: The braking unit and braking resistor are not installed. 1: The output circuit is grounded or short circuited. 2: Motor auto-tuning is not performed. 3: The voltage is too low. 4: A sudden load is added during operation. 5: The AC drive model is of too small power class. OUA 1: The input voltage is too high. 2: An external force drives the motor during acceleration. 3: The acceleration time is too short. 4: The braking unit and braking resistor are not installed. Overvoltage during deceleration OUD 1: The input voltage is too high. 2: An external force drives the motor during deceleration. 3: The deceleration time is too short. 4: The braking unit and braking resistor are not installed. Overvoltage at constant speed OUN 1: The input voltage is too high. 2: An external force drives the motor during deceleration. Control power supply fault UU External equipment fault EF Overvoltage during acceleration The input voltage is not within the allowable range. 1: External fault signal is input via DI. 2: External fault signal is input via virtual I/O. Solutions 1: Eliminate external faults. 2: Perform the motor autotuning. 3: Increase the acceleration time. 4: Adjust the manual torque boost or V/F curve. 5: Adjust the voltage to normal range. 6: Select rotational speed tracking restart or start the motor after it stops. 7: Remove the added load. 8: Select an AC drive of higher power class. 1: Eliminate external faults. 2: Perform the motor autotuning. 3: Increase the deceleration time. 4: Adjust the voltage to normal range. 5: Remove the added load. 6: Install the braking unit and braking resistor. 1: Eliminate external faults. 2: Perform the motor autotuning. 3: Adjust the voltage to normal range. 4: Remove the added load. 5: Select an AC drive of higher power class. 1: Adjust the voltage to normal range. 2: Cancel the external force or install a braking resistor. 3: Increase the acceleration time. 4: Install the braking unit and braking resistor. 1: Adjust the voltage to normal range. 2: Cancel the external force or install the braking resistor. 3: Increase the deceleration time. 4: Install the braking unit and braking resistor. 1: Adjust the voltage to normal range. 2: Cancel the external force or install the braking resistor. Adjust the input voltage to the allowable range. Reset the operation. www.ssinverter.info SSI700 User Manual Fault Name Undervoltage AC drive overload Display LU OL2 Maintenance and Troubleshooting Possible Causes 1: Instantaneous power failure occurs on the input power supply. 2: The AC drive's input voltage is not within the allowable range. 3: The bus voltage is abnormal. 4: The rectifier bridge and buffer resistor are faulty. 5: The drive board is faulty. 6: The main control board is faulty. 1: The load is too heavy or lockedrotor occurs on the motor. 2: The AC drive model is of too small power class. Solutions 1: Reset the fault. 2: Adjust the voltage to normal range. 3: Contact the agent or Ssinverter. 1: Reduce the load and check the motor and mechanical condition. 2: Select an AC drive higher power class. 1: Set P9-01 correctly. 2: Reduce the load and check the motor and the mechanical condition. 3: Select an AC drive of higher power class. 1: Lower the ambient temperature. 2: Clean the air filter. 3: Replace the damaged fan. 4: Replace the damaged thermally sensitive resistor. 5: Replace the inverter module. 1: Check the cabling of host computer. 2: Check the communication cabling. 3: Set P0-28 correctly. 4: Set the communication parameters properly. 1: Replace the faulty drive board or power supply board. 2: Replace the faulty contactor. 1: Replace the faulty HALL device. 2: Replace the faulty drive board. 1: Set the motor parameters according to the nameplate properly. 2: Check the cable the AC drive and the motor. Replace the main control board. 1: Handle based on overvoltage. 2: Handle based on overcurrent. OL1 1: P9-01 is set improperly. 2: The load is too heavy or locked rotor occurs on the motor. 3: The AC drive model is of too small power class. OH1 1: The ambient temperature is too high. 2: The air filter is blocked. 3: The fan is damaged. 4: The thermally sensitive resistor of the module is damaged. 5: The inverter module is damaged. Communication fault CE 1: The host computer is in abnormal state. 2: The communication cable is faulty. 3: P0-28 is set improperly. 4: The communication parameters in group “13” are set improperly. Contactor fault RL 1: The drive board and power supply are faulty. 2: The contactor is faulty. Current detection fault CC 1: The HALL device is faulty. 2: The drive board is faulty. Motor auto-tuning fault ER 1: The motor parameters are not set according to the nameplate. 2: The motor auto-tuning times out. EEPROM readwrite fault EP The EEPROM chip is damaged. AC drive hardware fault EH 1: Overvoltage exists. 2: Overcurrent exists. GF The motor is short circuited to the ground. Replace the cable or motor. OT The accumulative running time reaches the setting value. Clear the record through the parameter initialization function. Motor overload Module overheat Short circuit to Ground Accumulative running time reached www.ssinverter.info SSI700 User Manual Fault Name Accumulative power-on time reached Display Maintenance and Troubleshooting Possible Causes UT The accumulative power-on time reaches the setting value. Load(loss) becoming 0 LL The AC drive running current is lower than P9-64. PID feedback lost during running PD The PID feedback is lower than the setting of 10-26. Motor overheat OH2 1: The cabling of the temperature sensor becomes loose. 2: The motor temperature is too high. Solutions Clear the record through the parameter initialization function. Check that the load is disconnected or the setting of P9-64 and P9-65 is correct. Check the PID feedback signal or set 10-26 to a proper value. 1: Check the temperature sensor cabling and eliminate the cabling fault. 2: Lower the carrier frequency or adopt other heat radiation measures. 9.4 Common Faults and Solutions You may come across the following faults during the use of the AC drive. Refer to the following table for simple fault analysis. Table 9-2 Troubleshooting to common faults of the AC drive SN Fault Possible Causes 1: There is no power supply to the AC drive or the power input to the AC drive is too low. 2:The power supply of the switch on the drive board of the AC drive is faulty. 3: The rectifier bridge is damaged. 4: The control board or the operation panel is faulty. 5: The cable connecting the control board and the drive board and the operation panel breaks. 1: The cable between the drive board and the control board is in poor contact. 2: Related components on the control board are damaged. 3: The motor or the motor cable is short circuited to the ground. 4: The HALL device is faulty. 5: The power input to the AC drive is too low. Solutions 1: Check the power supply. 2: Check the bus voltage. 3: Re-connect the 8-core and 28-core cables. 4: Contact the agent or Ssinverter for technical support. 1 There is no display at power-on 2 “HC” is displayed at power-on. 3 “GF” is displayed at power-on. 1: The motor or the motor output cable is short-circuited to the ground. 2: The AC drive is damaged. 1: Measure the insulation of the motor and the output cable with a megger. 2: Contact the agent or Ssinverter for technical support. 4 The AC drive display is normal upon poweron. But “HC” is displayed after running and stops immediately. 1:The cooling fan is damaged or locked-rotor occurs. 2: The external control terminal cable is short circuited. 1: Replace the damaged fan. 2: Eliminate external fault. 1: Re-connect the 8-core and 28-core cables. 2: Contact the agent or Ssinverter for technical support. www.ssinverter.info SSI700 User Manual SN 5 6 Fault OH1 (module overheat) fault is reported frequently. The motor does not rotate after the AC drive runs. Maintenance and Troubleshooting Possible Causes 1: The setting of carrier frequency is too high. 2: The cooling fan is damaged, or the air filter is blocked. 3: Components inside the AC drive are damaged (thermal coupler or others). 1: Check the motor and the motor cables. 2: The AC drive parameters are set improperly (motor parameters). 3: The cable between the drive board and the control board is in poor contact. 4: The drive board is faulty. 7 The DI terminals are disabled. 1: The parameters are set incorrectly. 2: The external signal is incorrect. 3: The jumper bar across OP and +24 V becomes loose. 4: The control board is faulty. 8 The motor speed is always low in CLVC mode. 1: The encoder is faulty. 2: The encoder cable is connected incorrectly or in poor contact. 3: The PG card is faulty. 4: The drive board is faulty. 9 The AC drive reports overcurrent and overvoltage frequently. 1: The motor parameters are set improperly. 2: The acceleration/deceleration time is improper. 3: The load fluctuates. 10 “RL” is reported upon power-on or running. The soft startup contactor is not picked up. 11 is displayed upon power-on. Related component on the control board is damaged. Solutions 1: Reduce the carrier frequency (P0-15). 2: Replace the fan and clean the air filter. 3: Contact the agent or Ssinverter for technical support. 1: Ensure the cable between the AC drive and the motor is normal. 2: Replace the motor or clear mechanical faults. 3: Check and re-set motor parameters. 1: Check and reset the parameters in group P4. 2: Re-connect the external signal cables. 3: Re-confirm the jumper bar across OP and +24 V. 4: Contact the agent or Ssinverter for technical support. 1: Replace the encoder and ensure the cabling is proper. 2: Replace the PG card. 3: Contact the agent or Ssinverter for technical support. 1: Re-set motor parameters or re-perform the motor autotuning. 2: Set proper acceleration/ deceleration time. 3: Contact the agent or Ssinverter for technical support. 1: Check whether the contactor cable is loose. 2: Check whether the contactor is faulty. 3: Check whether 24 V power supply of the contactor is faulty. 4: Contact the agent or Ssinverter for technical support. Replace the control board. Warranty Agreement 1. The warranty period of the product is 18 months (refer to the barcode on the equipment). During the warranty period, if the product fails or is damaged under the condition of normal use by following the instructions, Ssinverter will be responsible for free maintenance. 2. Within the warranty period, maintenance will be charged for the damages caused by the following reasons: www.ssinverter.info SSI700 User Manual Maintenance and Troubleshooting a. Improper use or repair/modification without prior permission b. Fire, flood, abnormal voltage, other disasters and secondary disaster c. Hardware damage caused by dropping or transportation after procurement d. Improper operation e. Trouble out of the equipment (for example, external device) 3. If there is any failure or damage to the product, please correctly fill out the Product Warranty Card in detail. 4. The maintenance fee is charged according to the latest Maintenance Price List of Ssinverter. 5. The Product Warranty Card is not re-issued. Please keep the card and present it to the maintenance personnel when asking for maintenance. 6. If there is any problem during the service, contact Ssinverter’s agent or Ssinverter directly. 7. This agreement shall be interpreted by Ssinverter Co., Ltd. Website: www.ssinverter.info Warranty and production control no www.ssinverter.info ">

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Multiple voltage classes
- Vector control
- Diversified control modes
- Modbus-RTU communication
- Virtual I/O
- Rapid current limit
- PID parameters switchover
- Power dip ride through
- Timing operation
Frequently asked questions
The SSI700 supports two control modes: Sensorless Flux Vector Control (SFVC) and Voltage/Frequency (V/F) control.
The SSI700 supports communication via the Modbus-RTU protocol.
The SSI700 series features new functionalities like virtual I/O, rapid current limit, restoring user parameters, higher accuracy AI/AO, and more.