10,000W HEAVY DUTY HEATER
OWNER’S MANUAL
Model No.: PH-9100WS
10000W 240V 60Hz
7500W 208V 60Hz
IMPORTANT INSTRUCTIONS
READ & SAVE
PET OWNERS WARNING:
The health of some small pets including birds are extremely sensitive to the fumes
produced during the first-time use of many appliances. These fumes are not harmful
to humans but we recommended that you do not use your heater around birds and
small pets during its initial use until the manufacturing corrosion coatings burn off.
Technical support: 1-866-206-0888
Service email: [email protected]
1
TABLE OF CONTENTS
Important Instructions………………………………………
3
Specifications and Wiring Diagram………………………. 4
Parts of the heater ……………………….………………… 4-5
Installing Instructions……………………….………………
5-7
Operating Instructions……………………….…………....
7
Maintenance and Cleaning……………………………….
7
Troubleshooting…………………………………………….
8
2
IMPORTANT INSTRUCTIONS
PLEASE READ ALL INSTRUCTIONS BEFORE USING THIS HEATER
NOTE: There may be a trace of smoke or odor when unit is first operated. Don’t be
alarmed. This indicates that a drop of oil fell on the heating coil during the manufacturing
process. It will quickly evaporate and should not re-occur.
Make sure that the room in which the appliance is located is well ventilated during this
operation. It is normal for the appliance to emit small cracking sounds when you turn it on
for the first time. Do not be alarmed.
WHEN USING ELECTRICAL APPLIANCES, BASIC PRECAUTIONS SHOULD ALWAYS BE
FOLLOWED TO REDUCE RISK OF FIRE, ELECTRICAL SHOCK AND INJURY TO PERSONS
OR PROPERTY, INCLUDING THE FOLLOWING:
1) Read all instructions before using this heater.
2) This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. Keep
combustible materials, such as furniture, pillows, bedding, papers, clothes, and curtains at least 3’
(0.9 m) from the front of the heater and keep them away from the sides and rear.
3) Extreme caution is necessary when any heater is used by or near children or invalids and
whenever the heater is left operating and unattended.
4) Always switch off the heater when not in use.
5) Do not operate any heater after the heater malfunctions has been dropped or damaged in any
manner. Disconnect power at service panel and have heater inspected by a reputable electrician
before reusing.
6) Do not use outdoors.
7) To disconnect heater, turn off power to heater circuit at main disconnect panel.
8) Do not install less than 6 feet (1.8m) high from the floor and closer than 1 foot (0.3m) to any
adjacent vertical surfaces or walls. Keep at least 4.5 inches (11.5cm) from the back wall (with or
without using the wall hanging mounting bracket).
9) Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may
cause an electric shock or fire, or damage the heater.
10) To prevent a possible fire, do not block air intakes or exhaust in any manner.
11) A heater has hot and arcing or sparking parts inside. To reduce the risk of fire, do not use it in
areas where gasoline, paint, or flammable vapors and liquids are used or stored.
12) Use this heater only as described in this manual. Any other use not recommended by the
manufacturer may cause fire, electric shock, or injury to persons.
13) This product must be installed by a certified electrician, in accordance with local codes.
14) For supply cables, use 10 AWG (5.3 mm2) copper wires .
15) WARNING – RISK OF FIRE, DO NOT USE AS A RESIDENTIAL OR HOUSEHOLD HEATER.
CAUTION – High temperature, risk of fire, keep electrical cords, drapery, furnishings, and other
combustibles at least 3 feet (0.9 m) from the front of the heater and away from the side and rear.
SAVE THESE INSTRUCTIONS
3
SPECIFICATIONS
10,000W HEAVY DUTY HEATER
Model : PH-9100WS
Voltage : 1-Phase 208 / 240 V
Watts: 7500 / 10000 W
Frequency: 60 Hz
Recommended Heating Capacity: 1.25 watts / ft³ (0.03m³)
Wiring diagram:
PH-9100WN
PARTS OF THE HEATER
A
B
C
E
D
H
F
G
4
A.
B.
C.
D.
E.
F.
G.
H.
Wall Mount Bracket
Ceiling Bracket
Upper Housing
Louver for air direction
Tilt adjustable knob
Down Housing
Front Exhaust Grill
ON/OFF Switch
INSTALLATION INSTRUCTIONS
WARNING: All wiring must be installed by a certified electrician according to the electrical safety.
The ceiling heater must be grounded in accordance with all national and local building codes.
All Wiring procedures and connections shall be in accordance with the national and local
codes having jurisdiction.
NOTE: Compatible with a 240V Line Voltage Double Pole Wall Thermostat. Must be installed
by a Certified Electrician.
Before installation:
Disconnect the main supply connection.
Supply cables shall be 10 AWG (5.3 mm2) copper wires.
The heater must be connected to individual branch circuit protected by 60 Amp circuit breaker only.
Supply cables must be equipped with a dual pole circuit breaker rating at least 240V 40A/pole as
main cutoff switch of power connection to the heater.
Wiring compartment for accommodating supply cables and pigtail leads are adequate and
measured free space of 2524.67 cm3 .
CAUTION : High temperature, risk of fire, keep electrical cords, drapery, furnishings, and other
combustibles at least 3 feet (0.9 m) from the front of the heater and away from the side and rear.
WARNING: To reduce the risk of fire, do not store or use gasoline or other flammable vapors
and liquids in the vicinity of the heater.
INSTALLATION INSTRUCTION:
1. Keep the unit at least 6 feet (1.8m) away from the floor. This minimum distance must be
maintained.
2. Do not install closer than1 foot (or 0.3 m) to any adjacent vertical surfaces or walls.
3. Keep at least 4.5 inches (11.5cm) from the back wall (with or without using the wall hanging
mounting bracket).
4. Mark the drill-hole positions on the wall or ceiling for the mounting bracket.
5. Drill the required holes with diameter fit for the anchor provided for positioning the mounting
bracket.
6. Insert the anchors.
Wall Mount
Ceiling Mount
5
7. Attach the mounting bracket to the wall and secure with mounting screws.
8. Loose the tilt adjustment knobs, remove the cart.
9. Align the Hang Bracket to the knob screw holes.
10. Re-insert the knob and tighten.
11. Hook the unit to the mounting bracket and let the unit hang from the mounting bracket.
12. Insert the bolt provided through the mounting bracket and the heater handle; tighten with the
nut and washer.
Wall Mount
Ceiling Mount
13. Loosen the screw to remove the small cover in the rear of the heater.
14. Run the electrical power supply cable in conduit.
15. Secure the conduit to the back plate via the knock-out hole.
16. Make the connections properly with connectors which are suitable for the conductor size, in
cluding grounding wirings.
Pull all the conductors from the conduit. Strip 3/4 inch of insulation from each of the insulated
conductors. Make a right angle bend in the white insulated pigtail and place its stripped end next
to the stripped ends of the other white supply cable. Make sure that the bare ends are tight
together and square. Using lineman's pliers, twist the bare ends tightly together in a clockwise
direction, then screw one of the wire nuts tightly on the spliced conductors. Check to be sure
that no bare copper shows from beneath the wire nut. Repeat these steps for the black
conductor. Once the wire nuts are firmly in place, cover them with plastic electrical tape. The
grounding conductor is spliced in the same manner.
6
17. And after making the connections, arrange the pigtail leads of unit and power supply wires in
the wiring compartment.
18. Replace the wiring cover and lock in place with the screw.
19. Consult NEC code for other types of approved electrical wire splices & wire connectors.
OPERATING INSTRUCTIONS
WARNING - The heater must be properly installed before it is used.
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH :



Apply appropriate personal protective equipment (PPE) and follow safe electrical
workpractices. See NFPA 70E.
A circuit breaker must be installed and serviced only by qualified electrical personnel.
Always use a properly rated voltage sensing device to confirm power is off.
The switch on the heater is to start the Fan and Heater. Use the circuit
breaker as power ON/OFF device. The circuit breaker is to be installed by
certified electrican and shall be located in line of sight from the heater
location or shall be capable of being locked in open position. Follow the
operating instruction to reduce the risk of fire, electric shock, injury or death
to persons.

Switch on the circuit breaker to turn on the heater power.

Press the switch at the back of the heater to turn on the fan and heating function.
 To turn off the heater, press the switch turn off the fan and heating function. And then switch
off the circuit breaker. The circuit breaker serves as the power disconnection
means.
MAINTENANCE AND CLEANING
There is no user maintenance part except regular cleaning as following description. All other
servicing or maintenance should be performed by qualified service personnel.
Before any cleaning, make sure that:
1. Disconnect power supply at source. Switch off the circuit breaker.
2. Wait for 60 minutes to ensure the heating element has cool down, and your heater is now
ready for cleaning.
Regular Cleaning:
1. Do not use cleaning liquid or other chemicals to spray on the unit.
2. Interior dust can often be removed by using a vacuum cleaner with a crevice tool attachment.
3. To clean enclosure, use a clean, soft and lightly damp cloth to gently wipe off the dirt from the
surface of the unit. Be sure not to wet the heating element and the switches. Allow the unit to
dry completely before using it.
CAUTION: DO NOT ALLOW WATER TO RUN INTO THE INTERIOR OF THE HEATER AS THIS
COULD CREATE A FIRE OR ELECTRIC SHOCK HAZARD, DAMAGING THE UNIT.
7
TROUBLESHOOTING
If your heater fails to operate, please follow these procedures:
This heater is intended to be a ceiling-mounted heater. It has a thermal cut-off protection. If the
thermal cut-off protection trips, then, switch off the power. Switch off the circuit breaker.The
unit should reset automatically after 10 minutes. If the thermal cut-off protection trips again,
consult a certified electrician to determine the reason for overheating.
Problem
Probable Cause
Solution
Overheat protection has temporarily
deactivated the heater.
Turn the heater OFF; Switch off the
circuit breaker. Wait 10 minutes before
turning on the heater
Breaker/Fuse has been tripped.
Check your electrical box to confirm the
breaker has not been blown. This may
occur if the receptacle is shared between
other high consumption appliances.
Unit is not
heating.
The heater
is producing
a burning
smell.
Check & ensure there are no
combustible materials within 0.9
meters (3 feet) surrounding the
heater.
A drop of oil fell on the heating coil
during the manufacturing process. It
will quickly evaporate and should not
occur again.
Ensure a minimum clearance of 4.5
inches (11.5 cm) from both sides and
rear of heater to adjacent walls.
Remove any combustible items from the
heater.
Ensure room in which heater is situated is
well ventilated.
Reposition the heater so there is enough
space around the heater to the adjacent
walls.
PLEASE DO NOT ATTEMPT TO OPEN OR REPAIR THE HEATER YOURSELF. DOING SO
COULD CAUSE DAMAGE OR PERSONAL INJURY.