FC330 / B LIGHT BARRIER
RX - TX SYNCHRONIZED
INSTRUCTIONS MANUAL
innovative in electronics
DESCRIPTION
SMINN’S FC330 light barrier is composed by a RX
receiver and a TX emitter that can be powered with a
3V6 DC battery
Devices that are built using high quality materials and
components and the latest technology. They are made
taking into account the current regulations for usage in
residential, commercial and light industry environments.
Fig. 1
3 different positions of the lens. 180º horizontal rotation.
Fig. 2
Jumper configuration
Feature - Device
Jumper
Gain - RX
J1 (RX)
Frequency - TX
J2
Resistive Security Edge - TX J3
NC Security Edge - TX
J1 (TX)
ON
Normal
Fast
Not connected
Not connected
OFF
High
Slow
Connected
Connected
NOTE:
The fast transmission mode (J2 = ON) halves the battery life.
In slow mode (J2 = OFF) batteries can last up to 2 years depending on temperature, humidity
and initial charge.
Fig. 3
-
NA
C
NC
Jumper J1
1 2 3 4 5
+
EDGE
-
Receiver
SEC
+
Emitter
1 2 3 4 5
Jumper J3 ON
if not installed
+
-
Security input
Motor controller
Security Edge 8K2
NC Security contact
Join J1 ON if not used
12/24V AC/DC
Power Supply
Fig. 5
Placement
Security Edge connection
min 30 - 40 cm
Fig. 4
Align
+/- 5%
Fig. 6
7
-
4
3
5
1
6
8
+
+
9
1. PC front case (UV filter)
2. Front case screw
3. Case sealing O-ring
4. PA - FG Base
5. Wall sealing O-ring
6. Wall plug
7. Wall screw
8. Jumpers
9. Lithium batteries
2
Fig. 7
Light barrier terminal blocks.
Receiver
Emmiter
Adjustable
lenses
J1
J2
(RX)
J1 (TX)
J3
12/24 V
AC/DC
SEC
SAFETY
EDGE
R8K2
+
12/24 V
AC/DC
NO
COM
NC
OPERATION
Once the light barrier is correctly installed, the emitter sends a beam of
infrared light modulated by pulses to the receiver, setting up a safety
barrier. Each time this barrier is blocked, the receiver activates the internal
red led and activates the alarm relay. All regulations on security of the
installation must be strictly observed.
APPLICATIONS
The FC330 light barrier has been developed for protection in automatic
doors, barriers and blinds. Also for access detection in alarm systems and
traffic control.
INSTALLATION
Check the integrity of the product to be installed.
All the safety regulations associated with the installation to be carried out
must be strictly observed.
· Place it away from heat sources, humidity or excessive radiation and to a
minimum height of 30-40 cm from the floor, preventing reflection problems
with the light beam.
.
THE MANUFACTURER IS NOT RESPONSIBLE OF THE DAMAGE CAUSED BY AN
INCORRECT INSTALLATION OR IMPROPER OR CARELESS USE.
.
· Avoid GASES or INFLAMMABLE PRODUCTS, as they are a serious danger
for security in electric installations.
· Place emitter and receiver one in front the other, in the same axis and the
same height. The receiver includes a red LED to make alignment easier and,
once the system is powered, to indicate when there is no visibility between
the emitter and receiver.
· Select the operating distance with the Jumper J1 placed in the receiver.
See Fig. 7
Jumper J1
ON
Distance < 15 m
Jumper J1
OFF
Distance > 15 m (máximum range)
NOTE: the operating distance can be reduced because of external, adverse
conditions such as dust, excess of light, rain, fog, etc.
The emitter is ready to operate with a 2.4 / 2.8Ah 3.6V Lithium battery AA
type or with a 12/24V AC/DC power supply applied to terminals 1 and 2.
Battery powered
To increase battery life (2 years) you can adjust the frequency
modulation using the J2 jumper. See fig. 7
Jumper J2
ON
Fast mode
Jumper J2
OFF
Slow mode
External power supply
The emitter will set the frequency modulation to continuous mode
when powered with a 12/24V AC/DC power supply, achieving more
range regardless of the J2 jumper (Fig. 7).
Safety edge control
It is possible to connect an 8K2 safety edge assembled on the mobile gate
leaf to the terminals 4 and 5. The emitter checks the edge continuously,
interrupting the infrared beam when pressed and activating the security
relay in the receiver. If we do not connect the safety edge, Jumper J3 must
be connected. See fig. 7.
Safety contact control
The emitter is equipped with a safety NC input in terminals 2 and 3 that
deactivates the transmission of the infrared beam when that contact is
opened, putting the transmitter in standby mode. If we do not connect this
input, Jumper J1 (TX) must be connected. See fig. 7.
OPERATION VERIFICATION
To verify that the light barrier is operating, interrupt the beam of light and
check that the red led and the relay activate in the receiver. Without
interrupting the beam and with both emitter and receiver aligned, the led
must be off. With the beam interrupted or with the emitter or receiver not
aligned, the red led must be on and the relay must activate.
MAINTENANCE
FC330 light barriers do not require any special care, but it is necessary to
check their condition from time to time, clean the external casing of dust
and dirt making sure it has a nice appearance and operates correctly,
contacting a technician if there is any anomaly.
If the light barrier is battery powered, a routine of battery maintenance,
checking and replacement every 2 years should be followed to guarantee
the system will keep working perfectly.
The Lithium battery (Lithium-thionyl chloride Li-SOCl2) that supplies power
to the transmitter is an industrial range (-55ºC / +85ºC) 3V6 AA of 2000 up
to 2700 mAh. It is recommended to replace it with a battery of the same
kind and quality.
UNDER NO CIRCUMSTANCE IT SHOULD BE
DISPOSEDWITH THE COMMON WASTE
Note: dead batteries contain pollutant substances and they should be
handed in collection points for this kind of products according to the
current regulations.
WARRANTY
This product has undergone a complete TEST during its manufacturing
process that guarantees its reliability and proper operation.
The manufacturer provides 24 months of warranty to the product from the
date printed in the product and against any anomaly that it may present in
its appearance or operation.
Any damage caused by third parties, natural causes (flooding, fire,
lightning, etc), arising from improper handling or installation, vandalism or
any other cause non attributable to the manufacturer will void the warranty.
The warranty only covers repairs or replacement of the damaged device.
Any expenses derived from assembling, travelling, transport, natural wear
of parts, etc., and, in general, any expenses that are not part of the repairs
or replacement of the damaged element of the system are excluded.
The installer/provider will ask the manufacturer for an RMA number or
authorization for transport of the system in warranty. Without this previous
requisite, the manufacturer will not be able neither to process nor provide
warranty service.
WARNING
This product must be used in istallations which has been conceived for,
considering any other as improper use. The packaging and wrapping MUST
NOT be dumped in the environment. Keep products, packaging, wrapping,
documentation, etc., out of the reach of children.
Follow the current local, national or European regulations.
WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT
DIRECTIVE (WEEE)
In accordance with the European Directive 2002/96/EC about waste
electrical and electronic equipment (WEEE), the presence of this symbol
(see symbol at the bottom of this text) in the product or in the packaging,
means that this article shall not be disposed in local non-classified waste
streams. It is the user’s responsibility to dispose this product taking it to a
collection point designed for waste recycling of electrical and electronic
devices.
The separate collection of this product helps optimize the waste sorting
and recycling of any recyclable material and also decreases the impact on
health and the environment.
For more information about the correct wasting of this product, please
contact the local authority or the distributor where you acquired this
product.
TECHNICAL SPECIFICATIONS
Nominal range
Maximum range
Technology
IR ray adjustment
Infrared wavelength
Modulation frequency
10m ( 20 m jumper J1 = OFF )
15m ( 30 m jumper J1 = OFF )
Modulated IR
Horizontal -90º/0º/+90º
(+/-5%)
880 nm
600 Hz
Receiver Power Supply
Receiver Power Compsumption
Alimentación emisor
Transmitter Power Supply
Battery Life
12/24V AC/DC
< 50mA (100mA with activated relay)
2 x 3.6V Li batteries or 12/24V AC/DC
< 500uA
2 years aprox.
Ralay contact
Detection delay
Reset delay
0.5 Amp
< 30 ms
< 120 ms
.
Plastic Housing
Index of protection
Dimensions
Temperature range
PA6 + 30% FG
PC infrared + UV filter
IP65 (Mounted with closure gasket)
H112 x W52 x Z33 mm
-20/ +55ºC
Note: the light barrier by itself is not a complete security product; it is only
a part of the system. According to the current legislation for an automatic
door, regulations that allow to declare conformity on the manufactured
product will have to be taken into account.
CE DECLARATION OF CONFORMITY
The company
Declares:
The product
Manufactured by:
Under the trademark:
For use in:
ELSON SISTEMAS, S. L.
Pol. Torrelarragoiti, P6 - A3 - 1ª
48170 Zamudio - Vizcaya (SPAIN)
FC-330 adjustable IR light barrier
ELSON ELECTRÓNICA, S.A.
SMINN
Residential, commercial or light industry
environments.
This device meets the adequate provisions as long as its usage is compliant
to what was envisaged, having applied the following regulations.
Electromagnetic
compatibility:
89/336/CEE -
EN61000-6-2/3
Meeting totally or partially the following regulations:
EN13241-1 2004 / EN12453/5-2002
EN12978 2005 / EN61496-1/2
2011.10.14, Zamudio
innovative in electronics
José Miguel Blanco Pérez
Chief Technical Officer
T. +34 944 525 120
www. sminn.com
[email protected]
Pol. Torrelarragoiti, P6 A3 - 1ª
48170 Zamudio Bizkaia
SPAIN
">