XPR DINB100 SA Biometric Kit, DINB100 SA Biometric Reader, DIN RTT Remote Relay Unit User Manual
Below you will find brief information for Biometric Kit DINB100 SA, Biometric Reader DINB100 SA, Remote Relay Unit DIN RTT. This document describes the DINB100-SA, a standalone biometric system that can store up to 97 finger templates. It has one relay output and one exit button input. The reader can be connected to a remote relay unit at a secured area, which also plays the role of a request-to-exit push button. You can also add a proximity reader or keypad for additional entry modes such as Card or/and Finger, PIN Code or/and Finger, or Finger on Card. The complete setup and programming can be done by scrolling and tapping on the sensor or by using the keypad menu if a keypad is connected.
Advertisement
Advertisement
DINB100-SA
DINB100-SA-KIT
Standalone Biometric Kit
User Manual
DINRTT
www.xprgroup.com
v.b2
EN
Contents
1.0 INTRODUCTION
..............................................................
3
2.0 MOUNTING AND DISMOUNTING
..................................................
3
3.0 SPECIFICATIONS
..............................................................
3
4.0 APPLICATION DIAGRAM
.....................................................
4
5.0 WIRING
.........................................................................
4
6.0 RECOMMENDED SWIPING TECHNIQUE
...........................................
5
6.1 Tapping the sensor ............................................................
5
6.2 Scrolling the sensor up and down .................................................
5
7.0 INDICATION
....................................................................
5
8.0 QUICK PROGRAMMING
....................................................
6
8.1 Adding Master Finger and delete all users .........................................
6
8.2 Add User In Group 1
...........................................................
7
8.3 Add User In Group 2
...........................................................
7
8.4 Delete user
...............................................................
7
8.5 Delete All Users in Group 1 .......................................................
7
8.6 Delete All Users in Group 2 .......................................................
7
9.0 PAIRING - BIOMETRIC READER AND REMOTE RELAY UNIT
..............................
8
9.1 Pairing DINB100-SA with DINRTT
...................................................
8
9.2 Pairing DINB100-SA with RTT
.........................................................
8
10.0 KEEP THE DOOR UNLOCK
...........................................................
8
11.
0 DINB100-SA PROGRAMMING MENU
.................................................
9
11.1 Adding Users
.....................................................................
9
11.2 Delete User
.....................................................................
10
11.3 Delete All users
...................................................................
10
11.4 Delete Group of Users
.............................................................
11
11.5 Add Administrator
...............................................................
12
11.6 Delete Administrator
.............................................................
13
11.7 Settings
.........................................................................
14
11.7.1 Double Swipe Unlocks Door, Entry Mode, Remote Relay Touch Function
.................
15
11.7.2 Buzzer Sound, Backlight, Reset to defaults
....................................
16
11.8 Set Door Relay Time ...........................................................
17
11.9 Adding Users In Finger On Card Mode
(when Mifare Reader is connected)
..........................
18
12.0 PROGRAMING DINB100-SA WITH KEYPAD
.........................................
19
12.1 Adding Users
...................................................................
19
12.2 Delete User By User Location Number
...............................................
20
12.3 Delete User Group
12.6 Set Door Relay Time
................................................................
20
12.4 Delete All Users
...............................................................
12.5 Delete User by User Finger
21
......................................................
21
..........................................................
22
12.7 Buzzer Settings
.................................................................
23
12.8 Backlight Settings
..............................................................
24
12.9 Set the Touch Button Function
.....................................................
25
12.10 Unpair Remote Relay
12.11
Entry Mode Settings
12.12 Add Administrator
12.13 Delete Administrator
...........................................................
25
...........................................................
26
...........................................................
27
...........................................................
27
12.14 Reset to defaults ...........................................................
28
12.15 Double Swipe Unlocks Door
.......................................................
28
www.xprgroup.com
2
1.0 INTRODUCTION
DINB100-SA is a simple one-door standalone biometric system. The reader can store up to 97 finger templates, it has one relay output and one exit button input. If secure installation is needed, the reader can be connected to remote relay unit at secured area, which also plays the role of request-to-exit push button. Proximity reader or keypad can be added for additional entry mode (Card or/and Finger, PIN Code or/and Finger, Finger on Card). Complete setup and programming can be done by scrolling and tapping on the sensor or by keypad menu if keypad is connected.
The sensor incorporates dedicated sensing hardware to facilitate the detection of “spoofing” attacks based on fake fingers. This data is embedded into the image data stream, and is processed on the processor. The system is capable of detecting and defeating well-known fake finger mechanisms, such as molded “gummy” fingers.
DINRTT is remote relay control unit for the DINB100-SA(B100-SA) biometric reader. If secure installation is needed, the biometric reader can be connected to remote relay unit at secured area, which also plays the role of exit push button. It has two relay output and two exit button inputs.
2.0 MOUNTING AND DISMOUNTING
Do not install the device and cabling close to a source of strong electromagne c fields like radio-transmi ng antenna.
Do not place the device near or above hea ng equipments.
If cleaning, do not spray or splash water or other cleaning liquids but wipe it out with smooth cloth or towel.
Do not let children touch the device without supervision.
Note that if the sensor is cleaned by detergent, benzene or thinner, the surface will be damaged and the fingerprint can't be entered.
3.0 SPECIFICATIONS
SPECIFICATIONS DINB100-SA
Fingerprint Capacity:
Output:
Push Button Input:
Door Open Time:
Entry Mode:
97 templates
1 x Relay (2A/24V AC/DC)
Yes
Pulse (1, 3, 5, 10, 20, 30, 60sec) or Toggle(ON/OFF)
Finger
(Basic installation)
Finger or/and Card (when used with card reader DIN Card reader)
Finger or/and PIN code (when used with keypad DINPAD-M)
Finger on Card (when used with mifare reader DINMTPX-MF)
Programming:
Master/Admin Fingers:
Image resolution:
Backlight ON/OFF:
Buzzer ON/OFF:
Firmware upgrade:
Current Consumption:
Power Supply:
Indication:
Mounting:
IP Factor:
Storage/Operating Temperature :
Storage/Operating Humidity:
Dimensions(mm):
By scrolling and tapping on the sensor or by keypad
1 Master and 2 Admin Fingers
Up to 508 DPI
Yes
Yes via RS485 converter and windows application
9-14 V DC
Flush mount
IP40
-20°C to +50°C
5% to 93% RH without condensation
80 x 80 x 9
SPECIFICATIONS DINRTT
Output:
Push Bu on Input:
Door Time:
Backlight ON/OFF:
Buzzer ON/OFF:
Power Supply:
Current Consump on:
Moun ng:
IP Factor:
Opera ng Temperature:
Dimensions:
www.xprgroup.com
2 x Relay (2A/24V AC/DC)
2
Pulse (1 to 60sec) or Toggle (ON/OFF)
Yes
Yes
9-14 V DC
60 mA flush mount
IP40 (indoor use only)
-20°C to +50°C
80 x 80 x 9
3
DINB100-SA
DINRTT
4.0 APPLICATION DIAGRAM
DINRTT
(Op onal)
2 Relay Remote Unit and request-to-exit Bu on
RS485 (max. 50m)
Secur ed Ar ea
Outside
5.0 WIRING
Wiring DINB100-SA
Relay Output
NC
C
NO
NC
C
NO
Jumper (Adding Master Finger)
Electric Door Strike
(DC powered)
+
C
NO
NC
C
NO
DINB100-SA
Standalone Biometric Reader
Connection to additional card reader or keypad
12V
GND
B
A
PB
GND tamp tamp tamp tamp
12V
GND
PB
GND(PB)
PB
GND tamp tamp
12V
GND
B
A
+12V
GND
B
A
PB
GND tamp tamp
Power Supply
(9-14V DC)
RS485
Push Button
Tamper
Exit Bu on (NO)
Only the Biometric Reader
Note: 4 frames supplied with the kit
DINB100-SA
Alarm
+
-
12 VDC
Wiring DINB100-SA + DINRTT (Remote Relay Unit)
DINB100-SA
12 VDC
+
-
DINRTT
+
-
Door1
+
-
Door2
Relays
Biometric Reader + Remote Relay Unit
A B GND 12V
A B
GN
D
PB1
GN
D
GN
D
PB
1
GN
D
PB
2
Pb2
Push Bu on Inputs
www.xprgroup.com
+12V
GND
Exit Button
(NO)
RS485 max. 50m
GND
PB1
GN
D
PB
1
GN
D
PB
2
-
+
12 VDC
B
RS485
TA
MP
TA
MP
RS485
B A Tamp
B A
Tamp
A B
+12V GND
Power Supply
- Connect the Door Lock on the DINRTT relay
- The Biometric reader DINB100-SA and the remote Relay Unit
DINRTT should be connected with 4 wires: +, -, A and B (RS485)
4
6.0 RECOMMENDED SWIPING TECHNIQUE
Follow the below instructions for correct finger swiping
Starting from the first finger joint, place the selected finger on the swipe sensor and move it evenly towards oneself in one steady movement.
Result:
For a valid swipe: Tricolour Status LED turns green + OK Beep(short + long beep)
For an invalid or misread swipe: Tricolour Status LED turns red + Error Beep
( 3 short beeps)
6.1 Taping the sensor
Tap the sensor to enter Submenu or to confirm a command
Enter and confirm
6.2 Scrolling the sensor up and down
Scroll the sensor DOWN to navigate the programming menu
Navigate the Programming Menu
Scroll the sensor UP to exit the programming menu
Exit the Programming Menu
7.0 INDICATION
Tricolor Status LED
Green - Access Granted
Red - Access denied
Orange - Idle Mode
www.xprgroup.com
4 x Tricolor Programming LEDs
(red, green, orange)
5
OK Beep - short + long beep
Error Beep - 3 short beeps
Swipe Again - 2 short beeps
8.0 QUICK PROGRAMMING
8.1 Adding Master Finger and delete all users
DINB100-SA
1.Close the jumper on the back of the device.
2.Reset the Power of the device.
3.Wait for One long + mul ple short beeps
4.Open the jumper.
(short beeps will stop)
5.Wait for the bo om row LEDs to blink in Orange.
A B GND 12V
Blinking> <Blinking
6.Swipe the Master finger min.6 mes. (Un l Ok Beep)
x 6
Note: A er enrolling the Master finger the device will auto-Reset (wait for 7 seconds and the OK beep).
Note: This procedure also deletes all the users and administrators previously enrolled.
1. There is 1 Master Finger. The master finger can enroll/delete user and all the other se ngs. The Master finger can be changed ONLY with the jumper.
2. There are 2 Administrator Fingers. The administrator can do all the things that Master can do. The Master can delete the Administrator, but the Administrator can not delete the Master.
3. The User can be assigned to one of the 8 available User Groups. With the Quick programming feature, the Users are assigned in Group 1 or Group 2. For most of the installa ons 2 groups are enough and can be used as: Group
1 for permanent residents, Group 2 for guest and visitors.
4. The user can be deleted by swiping its user finger or by dele ng the group in which that user is enrolled. Once the Group of users is deleted, all the users within that group will be deleted.
5. The Groups are not limited by the number of users. (ex. Group 1 can contain 20 users, Group 2 can contain 70 users, but the total number must remain bellow 97...)
www.xprgroup.com
6
8.2 Add User In Group 1
Figure.1
1. Swipe the Master or Admin Finger
2. Swipe the user finger min. 6 mes (un l Ok Beep)
Master Finger x 1
User Finger x 6
8.3 Add User In Group 2
Figure.2
1. Swipe the Master or Admin Finger twice
2. Swipe the user finger min. 6 mes (un l Ok Beep)
Master Finger x 2
User Finger x 6
8.4 Delete User
Figure.1
1. Swipe the Master or Admin Finger
2. Swipe the user finger (already enrolled)
Master Finger x 1
User Finger x 1
8.5 Delete All Users in Group 1
6 sec.
1. Swipe the Master or Admin finger 3 mes,
2. Wait 6 seconds for the light pa ern on figure.4
3. Swipe the Master or Admin finger once more
Note: All fingers that are enrolled in Group 1 will be deleted.
Figure.4
8.6 Delete All Users in Group 2
6 sec.
Figure.6
1. Swipe the Master or Admin finger 4 mes,
2. Wait 6 seconds for the light pa ern on figure.6
3. Swipe the Master or Admin finger once more
Note: All fingers that are enrolled in Group 2 will be deleted.
Master Finger x 3
wait 6 seconds
Master Finger x 1
Master Finger x 4
wait 6 seconds
Master Finger x 1
If you make any mistake or you just simply want to exit Quick Programming, wait for the meout of 10 seconds.
With this, the quick programming is completed. The system is now opera onal with default value for Door Open Time of 3
seconds.
For more comprehensive programming, refer to the “DINB100-SA Programming” sec on.
Important:
When using proximity reader for Finger Or/And Card Mode, first present the Card then swipe the finger min. 6 mes.
When using keypad for Finger Or/And Pin Code mode first enter the PIN Code, then swipe the finger min. 6 mes.
When using Mifare card reader for Finger On Card Mode first swipe the finger min. 6 mes, then present a Card.
For Fast Dele ng a user in Finger On Card mode swipe the Master or Admin finger then present an exis ng user card www.xprgroup.com
7
9.0 PAIRING - BIOMETRIC READER AND REMOTE RELAY UNIT
If secure installation is needed, the reader can be connected to remote relay unit at secured area, which also plays the role of request-to-exit push button. Follow the instructions bellow to pair(couple) both devices or refer to the Remote
Relay’s Manual.
9.1 Pairing DINB100-SA with DINRTT
12 VDC
+
-
DINRTT
DINB100-SA
+
-
1 2
A B GND 12V
Exit Button
(NO)
GND
PB1
GN
D
PB1
GN
D
PB2 B
RS485
TA
MP
TA
MP
1. Close the Jumper. DINRTT beeps con nuously and the red led blinks.
2. Open the Jumper
3. Wait for Beep + OK Beep (short + short + long beep)
A er the OK beep, the coupling is done.
A B
+12V
GND
A B
RS485
-
+
12 VDC
max. 50m
9.2 Pairing DINB100-SA with RTT
12 VDC
+
-
+
-
DINB100-SA
RTT
ON
1 2
A B GND 12V
A B
+12V
GND
RS485
-
+
12 VDC
A B max. 50m
1. Put Dipswitch No.1 to posi on ON. RTT beeps con nuously and the red led blinks.
2. Put Dipswitch No.1 to posi on OFF.
3. Wait for Beep + OK Beep (short + short + long beep)
A er the OK beep, the coupling is done.
10.0 KEEP THE DOOR UNLOCKED
Swipe ANY enrolled finger twice (within 7 seconds) and the Door will stay unlocked, un l valid finger is swiped.
While the door is unlocked the tricolor status LED stays green.
To use this feature, enable the same from the menu.(page 15). It applies for product version 1.0.2.0.0 and above.
Note: Make sure that the door lock can withstand ac va on in longer periods.
User Finger x 2
www.xprgroup.com
8
11.0 DINB100-SA PROGRAMMING MENU
11.1 Adding Users
Swipe the Master/Admin finger 5 mes un l the light pa ern on figure.9 is shown
BL
Figure.9
x 5
Tap sensor
BL
BL
BL
BL
BL
Select User Group
Swipe the finger to select:
Group 1
Group 2
Group 3
Group 4
BL
BL
BL
BL
Group 5
Group 6
Group 7
Group 8
Tap sensor
BL
BL
Assign Relay Output
Swipe the finger to select:
Relay 1
Relay 2
BL
BL
Both
None
NOTE:
Swipe UPWARDS to exit the MENU
Tap sensor
(Orange Blinking)
Swipe the user finger for Finger mode min.6 mes.
When using proximity reader for Finger Or/and Card Mode, first present the Card then swipe the finger min. 6 mes.
When using keypad for Finger Or/And Pin Code mode first enter the PIN Code, then swipe the finger min. 6 mes.
Example:
Task: Add a user in Group2, that will ac vate Relay1.
Scroll Master Finger 5 mes, tap, scroll ones, tap, tap, swipe user finger 6 mes, swipe UP to exit.
www.xprgroup.com
9
11.0 DINB100-SA PROGRAMMING MENU
11.2 Delete User
Swipe the Master/Admin finger 7 mes un l the light pa ern on figure.12 is shown
Figure.12
x 7
Tap sensor
Blinking row >
Swipe finger or present Card or enter PIN
NOTE:
Swipe UPWARDS to exit the MENU
11.3 Delete All Users
OK Beep
Back to MAIN MENU
Swipe the Master/Admin finger 11 mes un l the light pa ern on figure.14 is shown
Figure.14
x 11
Tap sensor
NOTE:
Swipe UPWARDS to exit the MENU www.xprgroup.com
Blinking row >
Tap sensor to confirm or swipe UP to Cance l deleting...
OK Beep
10
Note: The Master and the Administrators will not be deleted
Back to MAIN MENU
11.0 DINB100-SA PROGRAMMING MENU
11.4 Delete Group of Users
Swipe the Master/Admin finger 6 mes un l the light pa ern on figure.13 is shown
Figure.13
x 6
Tap sensor
BL
BL
BL
BL
Select User Group to Delete
Swipe the finger to select:
Group 1
Group 2
Group 3
Group 4
BL
BL
BL
BL
Group 5
Group 6
Group 7
Group 8
Tap sensor
OK Beep
NOTE:
Swipe UPWARDS to exit the MENU
Example:
Task: Delete all users in Group3
Scroll Master Finger 6 mes, tap, scroll twice, tap, swipe UP to exit.
www.xprgroup.com
Back to MAIN MENU
Note: All fingers that are enrolled in the Group will be deleted.
11
11.0 DINB100-SA PROGRAMMING MENU
11.5 Add Administrator
Swipe the Master/Admin finger 12 mes un l the light pa ern on figure.10 is shown
BL
Figure.10
x 12
Tap sensor
BL
BL
Select Admin nr.
Scroll down to select:
Admin 1
Admin 2
Tap sensor
(Orange Blinking)
Swipe the Admin finger min.6 mes.(Un l Ok beep) x 6
Note: If keypad is connected, enter the User Pin Code , then swipe the user finger min.6 mes(Un l Ok Beep).
Back to MAIN MENU
(to Add User menu)
NOTE:
Swipe UPWARDS to exit the MENU
- There is 1 Master Finger. The master finger can enroll/delete user and all the other se ngs.
- The Master finger can be changed ONLY with the jumper.
- There are 2 Aministrator Fingers. The administrator can do all the things that Master can do. The Master can delete the Administrator, but the Administrator can not delete the Master.
www.xprgroup.com
12
11.0 DINB100-SA PROGRAMMING MENU
11.6 Delete Administrator
Swipe the Master/Admin finger 13 mes un l the light pa ern on figure.11 is shown
BL
Figure.11
x 13
Tap sensor
BL
BL
Select Admin nr.
Scroll down to select:
Admin 1
Admin 2
Tap sensor deleting..
OK Beep
NOTE:
Swipe UPWARDS to exit the MENU
Back to MAIN MENU
- There is 1 Master Finger. The master finger can enroll/delete user and all the other se ngs.
- The Master finger can be changed ONLY with the jumper.
- There are 2 Aministrator Fingers. The administrator can do all the things that Master can do. The Master can delete the Administrator, but the Administrator can not delete the Master.
www.xprgroup.com
13
11.0 DINB100-SA PROGRAMMING MENU
11.7 Se ngs
Swipe the Master/Admin finger 10 mes un l the light pa ern on figure.7 is shown
Figure.7
x 10
Tap sensor
Blinking row >
BL
BL
BL
By swiping finger select appropriate light pa ern
Swipe the finger to select:
Double Swipe Unlocks Door
BL
Sensor security
Entry mode
BL
BL
Remote Relay
Touch Function
Buzzer
Backlight
Reset to defaults
BL
Tap sensor
Continues on the next 2 pages
NOTE:
Swipe UPWARDS to exit the MENU
Entry Mode - used when addi onal proximity or keypad reader is connected
Remote Relay Touch Func on - Enabling/Disabling the Touch Bu on Func on in the remote relay Unit
Buzzer - Enabling/Disabling the Buzzer
Backlight - Enabling/Disabling the Backlight
go to next page
www.xprgroup.com
14
11.0 DINB100-SA PROGRAMMING MENU
11.7 Se ngs
11.7.1 Double Swipe Unlocks Door, Entry Mode, Remote Relay Touch Func on
Double Swipe
Unlocks Door
Entry MODE
Remote Relay
Touch Function
Double Swipe
Unlocks Door
Scroll down to select:
BL
1 ON
2 OFF
BL
product ver. 1.0.2.0.0
Tap sensor
BL
By swiping finger select entry mode
Scroll down to select:
Finger Finger AND Card
BL
Finger OR PIN Finger ON Card
BL
BL
Finger AND PIN
BL
Finger OR Card
BL
Tap sensor
BL
Touch Button ON/OFF
Scroll down to select:
1 ON
2 OFF
BL
Tap sensor
OK Beep
OK Beep
OK Beep
Back to MAIN MENU
Note:
Refer to Chapter 10 for this feature
NOTE:
Swipe UPWARDS to exit the MENU
Back to MAIN MENU
Example:
Task: Set the Reader to work in “Finger and Card” mode
Scroll Master Finger 10 mes, tap, scroll twice, tap, scroll 4 mes, tap, swipe UP to exit.
www.xprgroup.com
15
Back to MAIN MENU
11.0 DINB100-SA PROGRAMMING MENU
11.7 Se ngs
11.7.2 Buzzer Sound, Backlight, Reset to defaults
Buzzer sound Backlight Reset to defaults
Buzzer ON/OFF
Scroll down to select:
Remote OFF
Reader OFF
All ON
All OFF
Tap sensor
OK Beep
Backlight ON/OFF
Scroll down to select:
Remote OFF
Reader OFF
All ON
All OFF
Tap sensor
OK Beep
Back to MAIN MENU
Back to MAIN MENU
NOTE:
Swipe UPWARDS to exit the MENU
Example:
Task: Put the Buzzer OFF.
Scroll Master Finger 10 mes, tap, scroll 4 mes, tap, scroll ones, tap,, swipe UP to exit.
www.xprgroup.com
16
Reset to defaults
Tap to confirm:
BL
product ver. 1.0.2.0.0
Tap sensor
OK Beep
Back to MAIN MENU
Note:
Does not affect the fingerprints stored and the pairing
11.0 DINB100-SA PROGRAMMING MENU
11.8 Set Door Relay Time
Relay1 time
(for Relay 1 in DINB100-SA, RTT and DINRTT )
Swipe the Master/Admin
finger 8 times x 8
Tap sensor
Blinking row >
BL
BL
BL
BL
Select relay open time
Scroll down to select:
1 sec
3 sec
5 sec
10 sec
BL
BL
BL
BL
20 sec
30 sec
60 sec
Toggle
Tap sensor
Relay2 time
(for Relay 2 in DINRTT Remote Relay Unit)
Swipe the Master/Admin
finger 9 mes x 9
Tap sensor
Blinking row >
BL
BL
BL
BL
Select relay open time
Scroll down to select:
1 sec
3 sec
5 sec
10 sec
BL
BL
BL
BL
20 sec
30 sec
60 sec
Toggle
Tap sensor
OK Beep OK Beep
Back to MAIN MENU
NOTE:
Swipe UPWARDS to exit the MENU
Example:
Task: Put Relay1 to stay ac vated 10 seconds.
Scroll Master Finger 8 mes, tap, scroll 3 mes, tap,, swipe UP to exit.
www.xprgroup.com
17
Back to MAIN MENU
11.0 DINB100-SA PROGRAMMING MENU
11.9 Adding Users In Finger On Card Mode (when Mifare Reader is connected)
Swipe the Master/Admin finger 5 mes un l the light pa ern on figure.9 is shown
BL
Figure.9
x 5
BL
BL
Tap sensor
BL
Group 1
Group 2
BL
BL
Select User Group
Swipe the finger to select:
Group 3
Group 4
BL
BL
Group 5
Group 6
BL
BL
Tap sensor
Group 7
Group 8
NOTE:
Swipe UPWARDS to exit the MENU
BL
BL
Assign Relay Output
Swipe the finger to select:
Relay 1
Relay 2
BL
BL
Both
None
Tap sensor
(Orange Blinking)
Swipe the user finger min.6 mes (Un l Ok beep).
The backlight starts to blink green and the buzzer beeps.
x 6
Present the Card and hold it in the proximity field un l OK beep, which is indica on that the finger enrolled is wri en in the card.
In “Finger on Card” mode, the fingerprint is stored only into the Mifare card (Mifare Classic 1K/4K or DesFire) and not in the reader. The matching is done by first presenting the card, then swiping the finger. According to this, the system in “finger on Card” mode does not have capacity limit. Furthermore, the fingerprint is not stored in the reader’s memory, which disables any misuse of the stored fingerprint templates
Example:
Task: Add a user in Group2, that will ac vate Relay1.
Scroll Master Finger 5 mes, tap, scroll ones, tap, tap, swipe user finger 6 mes, present the card, swipe UP to exit.
www.xprgroup.com
18
12.0 PROGRAMING DINB100-SA WITH KEYPAD
12.1 Adding Users
Important:
To use the keypad for programming, Master Finger must be enrolled. Please refer to page 6, to enroll Master finger.
Then, set the Entry Mode to “Finger or PIN”. Please refer to page 14 & 15 to set the reader in “Finger or PIN”mode.
In addi on to that, set the keypad to work with the biometric reader:
Press B+000000
Press 0
Press 2 - slave mode
Press A
Press B+000000
Press 4
Press 0 -
Any PIN Code length with “A” in the end
Press A
7
A
1
4
2
5
8
0
9
B
3
6
Swipe Master/Admin finger or enter Admin PIN.
The Biometric reader starts to blink.
BL
BL
ADMIN PIN or x 5
1.
Press 1
2.
Enter user loca on number 01 to 97
3.
Assign relay. Press 1 for Relay1 or 2 for Relay2
4.
Assign user group 1 to 8.(Press 1 for group 1...)
5.
Press A to confirm
Op onal
Note:
The user is automa cally assigned to Relay1 and group1
BL BL
6.
Enter user PIN code. (1 to 8 digits)
7.
Press A to confirm
Swipe the User finger min.6 mes.(Un l Ok Beep) x 6
Op onal
To Enroll again go to step 1.
To Exit press 0, A
Example:
Task: Add a user no.5, with PIN Code: 12345, that will ac vate Relay1.
Scroll Master Finger 5 mes, press 1, press 05, press A, press 12345, press A, Swipe Finger 6 mes, press 0,A to exit www.xprgroup.com
19
12.0 PROGRAMING DINB100-SA WITH KEYPAD
12.2 Delete User By User Loca on Number
Swipe Master/Admin finger or enter Admin PIN.
The Biometric reader starts to blink.
BL
BL
ADMIN PIN or x 5
7
A
1
4
2
5
8
0
9
B
3
6
1.
Press 7.
2.
Enter user loca on number, 01 to 97.
3.
Press A to confirm.
To Exit press 0, A
12.3 Delete User Group
Swipe Master/Admin finger or enter Admin PIN.
The Biometric reader starts to blink.
BL
BL
ADMIN PIN or x 5
1.
Press 8.
2.
Enter group number, 0 to 8.
3.
Press A to confirm.
To Exit press 0, A
Note: All fingers that are enrolled in the Group will be deleted.
www.xprgroup.com
20
12.0 PROGRAMING DINB100-SA WITH KEYPAD
12.4 Delete All Users
Swipe Master/Admin finger or enter Admin PIN.
The Biometric reader starts to blink.
BL
BL
ADMIN PIN or x 5
7
A
1
4
2
5
8
0
9
B
3
6
1.
Press 9.
2.
Press 5,1,3,5,7.
3.
Press A to confirm.
To Exit press 0, A
12.5 Delete User by User Finger
Swipe Master/Admin finger or enter Admin PIN.
The Biometric reader starts to blink.
BL
BL
ADMIN PIN or x 5
1.
Press 6.
2.
Press A.
3.
Enter user PIN then press A or swipe the user finger.
To Exit press 0, A
www.xprgroup.com
21
12.0 PROGRAMING DINB100-SA WITH KEYPAD
12.6 Set Door Relay Time
Swipe Master/Admin finger or enter Admin PIN.
The Biometric reader starts to blink.
BL
BL
ADMIN PIN or x 5
7
A
1
4
2
5
8
0
9
B
3
6
1.
Press 2.
2.
Press 1 or 2 to select Relay1 or Relay2
3.
Select the me code from the Table1.
Table1.
Time Codes
1
2
3
4
5
6
7
8
Time Mode
1 sec
3 sec
5 sec
10 sec
20 sec
30 sec
60 sec
Toggle
4.
Press A to confirm.
To Exit press 0, A
Example:
Task: Put Relay1 to stay ac vated 10 seconds.
Scroll Master Finger 5 mes, press 2, press 1, press 4, press A, press 0,A to exit.
www.xprgroup.com
22
12.0 PROGRAMING DINB100-SA WITH KEYPAD
12.7 Buzzer Se ngs
Swipe Master/Admin finger or enter Admin PIN.
The Biometric reader starts to blink.
1.
Press 3,1.
2.
Select the Buzzer Code from the Table2.
Table2.
Buzzer Code
1
2
3
4
Buzzer Mode
Remote OFF
Reader OFF
All ON
All OFF
3.
Press A to confirm.
7
A
1
4
2
5
8
0
9
B
3
6
To Exit press 0, A
Note 1: When “Remote OFF” is selected, the buzzer is OFF in the remote relay unit. In the biometric reader and in the keypad the buzzer is ON.
Note 2: When “Reader OFF” is selected, the buzzer is ON in the remote relay unit. In the biometric reader and in the keypad the buzzer is OFF.
www.xprgroup.com
23
12.0 PROGRAMING DINB100-SA WITH KEYPAD
12.8 Backlight Se ngs
Swipe Master/Admin finger or enter Admin PIN.
The Biometric reader starts to blink.
1.
Press 3,2.
2.
Select the Backlight Code from the Table 3.
Table 3.
Backlight Code
1
2
3
4
Backlight Mode
Remote OFF
Reader OFF
All ON
All OFF
3.
Press A to confirm.
To Exit press 0, A
Note 1: When “Remote OFF” is selected, the backlight is OFF in the remote relay unit. In the biometric reader and in the keypad the backlight is ON.
Note 2: When “Reader OFF” is selected, the backlight is ON in the remote relay unit. In the biometric reader and in the keypad the backlight is OFF.
7
A
1
4
2
5
8
0
9
B
3
6
www.xprgroup.com
24
12.0 PROGRAMING DINB100-SA WITH KEYPAD
12.9 Set the Touch Bu on Func on
Swipe Master/Admin finger or enter Admin PIN.
The Biometric reader starts to blink.
1.
Press 3,3.
2.
Select the Touch Code from the Table 4.
Table 4.
Touch Code Touch Mode
1
2
Touch ON
Touch OFF
3.
Press A to confirm.
To Exit press 0, A
Remote Relay Touch Func on - Enabling/Disabling the Touch Bu on Func on in the remote relay Unit
12.10 Unpair Remote Relay
Swipe Master/Admin finger or enter Admin PIN.
The Biometric reader starts to blink.
www.xprgroup.com
1.
Press 3,5.
2.
Press 7,1,5,9.
3.
Press A to confirm
To Exit press 0, A
25
7
A
1
4
2
5
8
0
9
B
3
6
12.0 PROGRAMING DINB100-SA WITH KEYPAD
12.11 Entry Mode Se ngs
Swipe Master/Admin finger or enter Admin PIN.
The Biometric reader starts to blink.
1.
Press 3,4.
2.
Select the Entry Mode from the Table 5.
Table 5.
Entry Codes
1
2
3
4
5
6
Entry Mode
Finger
Finger or PIN
Finger and PIN
Finger or Card
Finger and Card
Finger ON Card
3.
Press A to confirm.
To Exit press 0, A
Example:
Task: Set the Reader to work in “Finger and PIN” mode
Scroll Master Finger 5 mes, press 3, 4, press 3, press A, press 0,A to exit.
www.xprgroup.com
26
7
A
1
4
2
5
8
0
9
B
3
6
12.0 PROGRAMING DINB100-SA WITH KEYPAD
12.12 Add Administrator
7
A
1
4
2
5
8
0
9
B
3
6
Swipe Master/Admin finger or enter Admin PIN.
The Biometric reader starts to blink.
BL
BL x 5
3.
4.
1.
2.
5.
Press 4,1.
Press 1 or 2 to select Admin1 or Admin2
Press A to confirm.
Enter Admin PIN code.(1 to max 8 digits)
Press A to confirm
Swipe the Admin finger min.6 mes.(Un l Ok Beep) x 6
To Exit press 0, A
- There is 1 Master Finger, but no master PIN Code. The master finger can enroll/delete user and all the other se ngs.
- The Master finger can be changed ONLY with the jumper.
- There are 2 Administrator Fingers and 2 Administrator PIN Codes. In order to enrol Admin, Master Finger MUST be enrolled first. The administrator can do all the things that Master can do. The Master can delete the Administrator, but the Administrator can not delete the Master.
12.13 Delete Administrator
Swipe Master/Admin finger or enter Admin PIN.
The Biometric reader starts to blink.
BL
BL
ADMIN PIN or x 5
www.xprgroup.com
1.
Press 4,0.
2.
Press 1 or 2 to select Admin1 or Admin2
3.
Press A to confirm.
To Exit press 0, A
27
12.0 PROGRAMING DINB100-SA WITH KEYPAD
12.14 Reset to defaults
product ver. 1.0.2.0.0
Swipe Master/Admin finger or enter Admin PIN.
The Biometric reader starts to blink.
1.
Press 3,6.
2.
Press 9,1,4,7.
3.
Press A to confirm
Note:
Does not affect the fingerprints stored and the pairing
12.15 Double Swipe Unlocks Door
product ver. 1.0.2.0.0
Swipe Master/Admin finger or enter Admin PIN.
The Biometric reader starts to blink.
1.
Press 3,3.
2.
Select the Double Swipe from the table
Double swipe Unlocks Door
1
2
Enable
Disable
To Exit press 0, A
3.
Press A to confirm.
To Exit press 0, A
Note:
Refer to Chapter 10 for this feature
This product herewith complies with requirements of EMC directive 2014/30/EU. In addition it complies with RoHS directive EN50581:2012
Visual Plus Corporation, s.a.
Drève Richelle 161
WOP G - Bte 34
1410 Waterloo - Belgium
www.xprgroup.com
28

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Standalone biometric system
- Stores up to 97 finger templates
- One relay output and one exit button input
- Connects to a remote relay unit
- Supports additional entry modes (card, PIN, Finger on Card)
- Programming via scrolling/tapping or keypad menu