ADAPT Colibri TM Active communicative air diffuser for the WISE system, ADAPT C ADAPT Colibri Quick facts Ź Supply air diffuser with an active damper Ź Pressure-dependent and cleanable Ź Integrated sensor module Ź Simple wiring, Plug & Play Ź Communication via Modbus RTU Ź Supplied complete with junction box, CONNECT Adapt Ź Complemented with the WISE templates, containing detailed descriptions for planning Ź Allows for control of: – Heat alternatively, cooling valve (max. 3 actuators per master) – Slaves (supply or extract air, 3 pcs) – Lighting (via relay) Quick Selection AIR FLOW – SOUND LEVEL – COOLING EFFECT max q (l/s) Size min q*) (l/s) 50 Pa / 30 dB(A) 150 Pa / 35 dB(A) max p**) (W) 160 0/5 55 60 530 250 0/10 85 90 860 *) The first value indicates closed damper, the second value indicates lowest adjustable air flow. **) Max. cooling effect is calculated at 't=8K and for an air flow at 50 Pa and 30 dB(A). 1 WISE Technical Description Design ADAPT is a series of flow-controlled supply air diffusers for the Swegon WISE system: s The air diffuser controls the airflow with an active damper inside the commissioning box, see figure 1. s An ADAPT diffuser is always supplied with a commissioning box. s Inside the air diffuser, is a controller providing all the required set points and control functions as well as a multi-functional sensor module, see figure 1. Functions in the Master diffuser s Cools/heats and ventilates with air. s Two stage cooling with water in the second stage, cannot be combined with heating. s Controls airflow with regard to temperature and presence. s Ventilation boost after longer periods of unoccupancy. s Provision for wiring to a CO2 controller. s Provision for manually setting set points. s Has provision for connection to a main control system (Modbus). s Emergency functions for closing / opening of the damper. s Control of the heating in sequence unless 2-stage cooling has been selected. s Indication via LED. Indicates current operating mode and warns of malfunctions in the diffuser. s Comfort control indicated by the LED if the room temperature or CO2 value deviates too much from the set point, not activated by default. Planning – WISE Templates See separate documentation, ”WISE Project manual”, available for download from www.swegon.se. In addition, Swegon sales personnel can supply WISE templates containing descriptions with detailed information regarding functionality, flowcharts, wiring diagrams and demarcation list for various constructions. 1 2 Sensor module A sensor module is integrated in all ADAPT supply air diffusers, containing the following functions: s A temperature sensor controls the airflow to maintain required temperature in the room. s A presence detector makes it possible to save additional energy by lowering the airflow when there are no occupants in the room. s The presence signal from the air diffuser can be fetched for controlling the lighting, for instance, and in this way save more energy. 3 Figure 1. The sensor module of ADAPT Colibri with connection for TUNE Adapt. 1. Temperature detector 2. In-operation indicator, green, red and orange LED. 3. Presence detector Connectivity In each delivery of a master diffuser, a CONNECT Adapt junction box is included: s The junction box replaces the coupling box which otherwise is mounted on a wall/ceiling for wiring a 24 V supply voltage to the air diffuser and Modbus networks. s Both air diffuser and junction box are equipped with RJ45 quick-fit connectors for quick and fault-free wiring. s The device has provision for connection to a main control system (BMS/SCADA) via ModBus. s Accessory cable, LINK Modbus (RJ12) can be connected between air diffuser and junction box. The air diffuser will then be ready for the main control system. s From the junction box, control functions for heating in sequence, CO2 sensor and set point adjuster, can also be connected. 2 Swegon reserves the right to alter specifications. Figure 2. Junction box, CONNECT Adapt. 20121114 www.swegon.com WISE Installation Maintenance A detailed installation instruction is enclosed with each delivery and can also be downloaded from www.swegon. s The ADAPT air terminals can be cleaned on the outside, if necessary, using lukewarm water with dishwashing detergent added. s The duct system is accessible without need for tools. (See the separate installation instruction) 1. The commissioning box can be suspended from a ceiling and connected to duct system. Use hanger system A or B. 2. Press the ADAPT Colibri air diffuser into the outlet of the commissioning box and secure it with screws or pop rivets. Readjust the hanger rods of the commissioning box if needed, so that the air diffuser sits tight against the ceiling, or the framework of the modular suspended ceiling. Declaration Declaration of Construction Materials is available for download from www.swegon.com. Electrical data ADAPT is supplied with power via the junction box. For more information about various wiring and room solutions, see the Technical Section. A Supply voltage B 24 V AC ±10 % Max. power consumption 3 VA Cable rating 0,6 A 0 °C - +50 °C Forms of delivery s Some of the ADAPT-products are available from stock with standard settings. s At delivery, a master air diffuser contains a complete air diffuser with commissioning box, junction box CONNECT Adapt and 5 metre long RJ45 cable LINK Adapt. s Delivery of a slave air diffuser contains a complete air diffuser with commissioning box and 5 metre long RJ45 Standard settings Temperatures (°C) Presence 22 ±1K Absence 22 +3 / -2 K Commissioning Night-time cooling 18 s Normally, the ADAPT air terminals are preset from the factory based on design values. s The TUNE Adapt hand-held terminal is used for manually checking the current air flow through the air diffuser, and for changing set points, if required. s For more information, see the installation - Commissioning - Maintenance instruction as well as the TUNE Adapt user manual. Morning heat 25 Airflows (l/s) Absence Min. airflow Max. airflow The smallest size 0/5 10 60 The largest size 0/10 15 90 Air quality (ppm) Min. Max. 800 1000 Materials and finish Presence s ADAPT air terminals are made of galvanized sheet steel, with parts made of plastic, rubber and also contain electronic components. s The ADAPT air terminals are powder coated in Swegon’s white interior standard colour RAL 9010, both on the inside and on the outside. s The sensor module and junction box are made of ABS plastic. s The commissioning box is made of galvanized sheet steel with internal insulation. Switch on delay Figure 3. Adapt Colibri, installation. Swegon reserves the right to alter specifications. CO2 Switch out delay 0 sec. 20 min. Communication Modbus RTU by RS-485 Modbus ID Speed 1 38,400 bps Bit length 8 bits Stop bits 1 bit Parity 20121114 None www.swegon.com 3 ADAPT Colibri Ambient temperature WISE Sizing Engineering graphs s The specified sound levels dB(A) are applicable to rooms with an equivalent sound absorption area of 10 m2 (4 dB room attenuation). s The throw L0.2 is measured under isothermal discharge conditions. s Recommended max. permitted temperature below room temperature is 12 K. s All technical data applies to 360° distribution pattern. s For calculating the air stream propagation, air velocities in the occupancy zone, or sound levels in rooms with other dimensions, we refer to our ProAir Web calculation program. ProAir Web is available at www.swegon.com. Air flow – Pressure drop – Sound level – Throw s The diagrams should not be used for commissioning. s The dB(C) value is normally 6-9 dB higher than the dB(A) value. s Sizing example – size 160: – Given airflow 10-50 l/s at Pt 50 Pa. – Max. sound level 27 dB(A) – Throw = 2,0 m m in ADAPT C 160 40 dB(A) 1000 Sound data 35 500 400 Sound power level, Lw (dB) Table, Kok Size m ax pt Pa 30 300 25 200 20 Mid-frequency (Octave band) Hz 100 63 125 250 500 1000 2000 4000 8000 160 0 7 5 -2 -6 -10 -13 -7 250 1 5 2 -1 -3 -9 -12 -10 Tol. ± 2 2 2 2 2 2 2 2 50 40 30 20 3 4 5 10 20 Sound attenuation 'L Table 'L 125 250 500 1000 2000 4000 8000 160 15 9 9 20 19 15 16 14 250 13 8 10 19 16 13 16 16 Tol. ± 2 2 2 2 2 2 2 2 0,3 20 50 0,4 0,5 30 40 50 100 200 l/s 300 100 200 300 400 500 1 2 3 4 m3/h 5 10 l0,2 m ADAPT C 250 pt Pa 40 dB(A) 1000 m ax Mid-frequency (Octave band) Hz 63 40 m in Size 0,2 30 35 500 400 30 300 200 25 20 100 50 40 30 20 4 5 10 20 30 0,2 4 Swegon reserves the right to alter specifications. 20121114 20 40 0,3 50 0,4 0,5 30 40 100 50 200 1 100 300 2 200 3 4 300 l/s 400 1000 m3/h 400 500 5 www.swegon.com 10 l0,2 m WISE Dimensions and weights Ordering key Size A B C ØD Ød 160 595x595 504 332 159 250 250 595x595 622 388 249 315 Size E F G H K Weight, kg 160 314 201 214 450 100 8,5 Connection dimensions: 250 395 300 247 575 140 11,3 M: Master, S: Slave Product Rectangular active air diffuser for ceiling ADAPT C c -bbb -c Version: N.B.! Specify absence, min./max. airflows in your specification! CL = Center line Standard range: Size: 160, 250 Accessories DETECT Quality Temperature and CO2sensor with set point selector knob E Hand-held terminal for reading/changing settings TUNE Temp Temperature adjuster LINK Modbus RJ12-cable for connecting up Modbus RTU LINK Adapt RJ45 cable for connecting up in other lengths SPLIT Link Split connector FIX Link For securing cords to ducts, etc. POWER Adapt Transformer ACTUATOR Valve actuator, on/off VALVE Radiator valve ADAPT Relay Relay for light or heat control ADAPT TR Semi-conductor relay for lighting or heat control CABLE Ext Extension cable between box and air diffuser LINK Wa Network cable for Modbus, complies with the EIA-485 standard Figure 4. ADAPT Colibri, dimension figure. Each accessory is described in more detail in a separate product sheet available at www.swegon.se. Swegon reserves the right to alter specifications. 20121114 www.swegon.com 5 ADAPT Colibri F TUNE Adapt
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project