Signet 8150 Flow Totalizer User Manual
Below you will find brief information for 8150 Flow Totalizer. The Signet 8150 Flow Totalizer is a battery-powered instrument capable of providing uninterrupted flow and total volume information for 4 years and beyond. The unique features of the 8150 include: easy setup and display selection with 4-button keypad, user selectable security access to prevent unwanted programming changes, displays flow rate from 0.001 to 9999 engineering units with an auto-ranging decimal point, three totalizers, one permanent and two that are independently resettable, displays elapsed time between operating periods, integral mount and panel mount options, 3.6 V Lithium batteries last 4 years nominal in most applications, non-volatile memory stores all programming and totalizer values even when batteries are removed.
Advertisement
Advertisement
Signet 8150 Flow Totalizer
*3-8150.090-1*
3-8150.090-1 Rev. E 2/06 English
Topic:
2. 1
5. Battery Installation and Replacement 4
7. Security Code 6
9. Automatic Calibration 9
English
Topic:
10
11. Total K-factor 11
13. Decimal point placement 13
16. Troubleshooting
17. Flow and Totalizer K-factor selection
18. K-factor Charts
16
16
17
1. Description
The Signet 8150 Flow Totalizer is a battery-powered instrument capable of providing uninterrupted fl ow and total volume information for
4 years and beyond. The unique features of the 8150 include:
• Easy setup and display selection with 4-button keypad
• User selectable security access to prevent unwanted programming changes.
• Displays fl ow rate from 0.001 to 9999 engineering units with an auto-ranging decimal point.
• Three totalizers, one permanent and two that are independently resettable.
• Displays elapsed time between operating periods.
• Integral mount and panel mount options
• 3.6 V Lithium batteries last 4 years nominal in most applications.
• Non-volatile memory stores all programming and totalizer values even when batteries are removed.
Dimensions
Optional
Rear
Cover
92 mm
96 mm
96 mm
(3.8 in.)
82 mm
41 mm
56 mm
97 mm
SIDE VIEW
Panel Mount
96 mm
Front View
42 mm
(1.7 in.)
60 mm
(2.3 in.)
102 mm (4.0 in.)
Integral Mount
106 mm
Universal Mount
2. Specifi cations
General
Compatibility:
Input Frequency Range:
Accuracy:
Signet 515, 525, 2517 Flow Sensors
1 to 400 Hz
±0.5% of reading
Enclosure:
• Rating:
• Dimensions:
• Case material:
• Keypad material:
NEMA 4X/IP65 (front panel)
1/4 DIN (96 x 96 x 50 mm)
PBT resin
(3.8 x 3.8 x 2.0 in.)
Sealed 4-key silicon rubber
Display: LCD type
• 4-digit upper line: fl ow rate
• 8-digit lower line: Three totalizer options:
Permanent Totalizer for life of instrument
Totalizer 1: resettable from keypad or remote 30 m (100 ft)
Totalizer 2: resettable with security code only
• Display Contrast: Automatic
Electrical:
• Battery: Two 3.6V Lithium thionyl chloride,
AA-size
• Sensor power output: +3.6 VDC @ 20µA
• Battery life: 4 years nominal @ 50°C (122°F)
• Low Battery indication: Battery symbol on LCD display
Environmental:
• Operating Temperature: -10°C to 65°C (14°F to 149°F)
• Storage Temperature: -40 to 100°C (-40 to 212°F)
• Relative Humidity: 0 to 95% Non-condensing
Shipping Weight: 0.5 kg (1.1 lbs.)
Quality Standards:
• EN 61326: 2002 Class B
• Manufactured under ISO 9001:2000 for Quality and ISO
14001:2004 for Environmental Management
3. Installation
3.1 Integral Installation with Field Mount Totalizer
Flow
Totalizer
(3-8150-1)
Integral adapter Kit
(3-8051)
Integral Mount
3-8150-PO
3-8150-P1
3-8150-TO
3-8150-VO
Integral
Flow Sensor
(3-8510-XX)
3.2 Remote Field mount on wall
The parts identifi ed in Bold type are required for this installation.
Other parts are shown for reference only.
Use 2-conductor shielded cable no more than 30 m (100 ft.) long.
Universal
Conduit Base
(3-8050)
Flow
Totalizer
(3-8150-1)
Terminal Cover
(4-3111)
Signet
Fittings
3.3 Plastic sensor installation tips
• Lubricate the sensor O-rings with a suitable lubricant.
Do not use any petroleum based lubricant that will attack the
O-rings.
• Using an alternating/twisting motion, lower the sensor into the fi tting, making sure the installation arrows on the black cap are pointing in the direction of fl ow.
• Engage one thread of the sensor cap then turn the sensor until the alignment tab is seated in the fi tting black conduit cap sensor
bale tab notch. Hand tighten the sensor cap.
DO NOT use any tools on the sensor cap or the cap threads and/or fi tting fl ange threads will be damaged.
notch sensor cap
Integral
Adapter kit
(3-8051)
Liquid-tight Connector
(3-9000.392-1)
Integral
Flow Sensor
(3-8510)
Signet
Fittings
1. Insert the wires from the sensor through the yellow conduit base and locking ring.
2. Insert the locking ring into the conduit base, aligning it so that the square tab is close to the conduit ports.
3. Insert the mounting screw into the conduit base so the head of the screw presses down on the locking ring when tightened.
4. Connect sensor wires to the terminal connections on the integral totalizer or terminal cover.
5. For remote assembly, connect output wires to terminal cover output.
6. Route the output wires through the conduit port in the conduit base. Use a liquid-tight connector or conduit connector to prevent moisture from entering the assembly.
7. Place totalizer or cover onto conduit base and twist to lock in place.
3-8150
Flow Totalizer
Mounting
Screw
Conduit
Base
Kit
Locking
Ring
5
Conduit
Base
Sensor wires
2
Do not use this hole.
Square Tab
The Mounting Screw for the
Locking Ring goes into the Conduit
Base (not the Locking Ring) -- the screw head rests on the lip of the
Locking Ring
Conduit
Ports
8150 Flow Totalizer
3.5 Remote Field mount on pipe
The parts identifi ed in Bold type are required for this installation.
Other parts are shown for reference only.
3.6 Remote Installation with Panel mount totalizer
The parts identifi ed in Bold type are required for this installation.
Other parts are shown for reference only.
Use 2-conductor shielded cable no more than 30 m (100 ft.) long.
Totalizer
Panel Mount
(3-8150-1P)
Signet Total Flow
ENTER
Standard Mount
Paddlewheel
(P51530)
Flow
Totalizer
(3-8150-1)
Signet
Fittings
Standard Mount
Paddlewheel
(P51530)
Universal
Mounting Kit
(3-8050)
Signet
Fittings
• The 8150-1P Panel-mount Totalizer is a standard ¼ DIN package. Use a 92x92 mm punch tool to make the panel cutout.
• Minimum spacing of 25 mm (1 in.) between panel units is recommended.
gasket panel terminals mounting bracket
92 x 92 mm
(3.62 x 3.62 in.)
latch
2
1
Pwr
System
Loop -
System
Pwr
Loop +
4 Output -
3
Output + nd
Sensr G )
7
6
5
Sensr V+
(BLAC
K)
Panel cutout
Panel Mount
Installation Detail
quick-clips
8150 Flow Totalizer 3
4. Wiring
• The wiring is identical for the panel mount and the fi eld mount versions of the totalizer.
• Only one wire should be inserted into a terminal. Splice double wires outside the terminal.
• External Reset for Total #1: Use no more than 30 m (100 ft.) of 2-conductor twisted-pair cable connected to a dry contact (for example, an ordinary door-bell button or relay contact).
• Only Totalizer #1 can be be reset by the external connection.
• Total #1 will not be displayed unless it is the standard totalizer selection.
10 mm
Instructions
1. Remove 10mm (
3
/
8
in.) of insulation from sensor cable conductors.
2. Press down on orange lever to open terminal.
3. Insert wire into terminal until it hits bottom.
4. Release the lever to secure wire.
Sine wave Input Wiring
Use this wiring scheme for
Signet models 515, 525 and 2517.
+
#1
-
+
#2
-
3
4
1
2
5
6
Splice BLK and SHLD together outside of terminal
BLACK
RED
SH
IE
LD
Connect shield to Ground wire
525
Totalizer 1
Remote reset
515
2517
Terminal Function
3
4
Open Collector Signal
DC Power to sensor
5. Battery Installation and Replacement
Two 3.6V Lithium thionyl chloride batteries, AA-size (7400-0011) are included with the totalizer.
NOTE: THE 8150 WILL NOT OPERATE WITH STANDARD 1.5 V ALKALINE BATTERIES. USE 3.6 V LITHIUM BATTERIES ONLY!
• Observe polarity! Note that both batteries should face the same direction.
• When the “low battery” indicator appears on the display, both batteries should be replaced within 90 days.
• Remove and replace battery #1 fi rst, then remove and replace battery #2.
This ensures that all settings and totalizer values are saved.
• If the low battery symbol reappears for more than 10 seconds after installing new batteries, one battery is reversed, or battery #2 was installed before battery #1.
• Secure the batteries by fastening the Velcro® straps.
Signet Total Flow
ENTER
CAUTION
When replacing batteries, remove and replace one battery at a time
Remove and replace this battery first.
+ +
3
4
1
2
5
6
-
Note: Lithium Batteries
Dispose of properly!
Replace with 3.6 V Lithium battery
DISPOSE OF EXPENDED BATTERIES PROPERLY!
Lithium batteries contain hazardous chemicals. Dispose of batteries according to local regulation.
4 8150 Flow Totalizer
6. Operation
The 8150-1 display shows the fl ow rate in large numerals and a totalizer value in smaller numerals. Any one of three different totalizers can be selected as the standard display (See section 8 for detailed information on the totalizers).
Press the UP or DOWN keys to scroll through all three totalizer values during normal operation.
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Signet Total Flow
ENTER
6.1 No Flow and ELAPSED TIME Display
If the fl ow stops, the Totalizer displays the number of hours since fl ow was last detected. This display will alternate with the normal
FLOW RATE and standard TOTAL display every fi ve seconds.
Any movement of the rotor in the pipe will reset the ELAPSED
TIME display.
Illustrated: No fl ow for 3 hours
Signet Total Flow
ENTER
5 sec.
Signet Total Flow
ENTER
Totalizers are shipped from the factory with these standard settings:
AUTO CALIBRATION
FLOW K-FACTOR
TOTAL K-FACTOR
TIMEBASE
DECIMAL
SPEED
SENSITIVITY
60
1
Minutes
XXX.X
30 s
6
SECURITY CODE 0-0-0-0
DEFAULT TOTALIZER Permanent
TOTALIZER #2 RESET
No setting; See section 9 for detailed information.
Number of sensor pulses per volumetric unit; Refer to sensor manual.
Set the number of volumetric units per totalizer count; see section 11.
Select fl ow rate in seconds, minutes, hours or days. Section 12.
Set the maximum decimal resolution. Section 13.
Zero to 120 seconds averaging stabilizes readings in erratic fl ow conditions. Section 14.
Momentarily overrides SPEED when fl ow rate changes signifi cantly. Section 15.
Set a private code to prevent tampering. Section 7.
Select from three totalizer options. Section 8.
Reset Totalizer #2 after entering the security code. Section 8.3.
8150 Flow Totalizer 5
7. Changing the Security Code
The security code prevents unauthorized tampering with calibration and operational settings in the 8150.
The factory standard code is 0-0-0-0. Change the code to any 4-digit number by following these steps:
Example: Change the security code from the factory standard 0-0-0-0 to custom setting 1-0-0-1
1. Hold the ENTER key for 2 seconds, then enter the current
SECURITY CODE.
If working with a new unit, press the ENTER key again. The display shows the fi rst menu item (Auto CAL)
2. Press the UP key three times to scroll to Sec Code.
3. Press RIGHT ARROW to edit the code.
The leading digit on the display will fl ash.
4. Press the UP key one time to scroll the fl ashing digit to 1.
5. Press the RIGHT key three times to advance the fl ashing element to the last digit.
6. Press the UP key one time to scroll the fl ashing digit
2
RotoFlo
1
Signet Total Flow
3
ENTER
8. Press the UP and DOWN keys together to exit the
Calibrate menu, store the new settings and return to normal operation.
NOTE:
Record and store your security code in a safe place!
2 s
4
Signet Total Flow
ENTER
Enter Security code
5
7. Press the ENTER key to complete the edit process.
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Signet Total Flow
ENTER
6
Signet Total Flow
ENTER
7
Signet Total Flow
ENTER
8
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Signet Total Flow
ENTER
6
7.1 Using the Security Code
A numerical code (0-0-0-0 to 9-9-9-9) must be entered before any of the menu selections can be modifi ed.
• The code is set at 0000 from the factory. To change the code, see section 7.
Example: Enter security code of 1001:
1. Hold the ENTER key for 2 seconds. The display shows factory standard access code of
0000, with the fi rst zero
1
2. Press the UP key one time to scroll the fl ashing zero to 1.
3. Press the RIGHT key three times to advance the fl ashing character to the last place value.
4. Press the UP key one time to scroll the fl ashing zero to 1.
5. Press the ENTER key. The display now shows the fi rst item
4
Signet Total Flow
ENTER
Signet Total Flow
ENTER
2 s
2
5
Signet Total Flow
ENTER
Signet Total Flow
ENTER
3
Signet Total Flow
ENTER
Signet Total Flow
ENTER
8150 Flow Totalizer
8. Totalizer Setup and Operation
During normal operation the 8150 displays the fl ow rate and one selected totalizer value. Any one of the three totalizers can be set as the standard display: The other two totalizers can be viewed by pressing the keypad. The display will automatically return to the standard selection after fi ve minutes.
The PERMANENT Totalizer is identifi ed directly on the LCD.
• This totalizer records all input from the time of manufacture.
• The permanent totalizer cannot be reset.
• Application: The permanent totalizer should be selected as the standard if the system is monitored and the total recorded regularly.
Total 1 (tot1) can be reset from the keypad or from the external RESET
(see wiring, section 4) without the security code.
• Total 1 is identifi ed by a fl ashing display every six seconds.
• Application: Use Total 1 to measure water usage for a recurring period, as for a daily discharge volume.
Total 2 (tot2) can be reset only by entering the security code in the calibration menu.
• Total 2 is identifi ed by a fl ashing display every six seconds.
• Application: Use Total 2 for extended measurement periods, as for a monthly discharge volume.
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Signet Total Flow
ENTER
8.1 Defi ne the standard Totalizer
Any of the three totalizer functions can be set as the standard display, or select SCAN to display all three totalizers in sequence. The
PERMANENT totalizer is the factory standard selection.
Example: Change the standard Totalizer from PERMANENT to Totalizer #1
1. Press ENTER key for 2 seconds. (Display shows security key symbol and 0-0-0-0. Set security code and press ENTER key.)
2. Press UP key two times.
Display shows "def tot" and the
"PERMANENT" label.) label begins to fl ash
4. Press UP key one time. Display changes to fl ashing tot 1".
5. Press ENTER key to complete the edit process.
6. Press UP and DOWN keys together to store new value in the memory.
The display will show "Storing" for a few seconds, then return to normal operation.
NOTE: The new totalizer selection will appear after a 5 minute delay.
1
2
Signet Total Flow
ENTER
Signet Total Flow
ENTER
3
Signet Total Flow
ENTER
2 s
4
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Enter Security code
5
Signet Total Flow
ENTER
6
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Signet Total Flow
ENTER
5 m
Signet Total Flow
ENTER
Signet Total Flow
ENTER
8150 Flow Totalizer 7
8.2 Resetting Totalizer 1
1. Press UP key to scroll to "total 1" display.
2. Press and hold the RIGHT arrow key until the display shows "rst tot1".
The totalizer will fl ash for 8 seconds and then it will automatically reset to 00000000.
• Press the ENTER key while the display is fl ashing to reset immediately.
• While the total value is fl ashing, you can cancel the reset by pressing UP and DOWN keys together.
• Totalizer #1 will be displayed for 5 minutes after the reset, then the standard totalizer selection will return.
• Press the UP or DOWN key to scroll back to the standard display immediately.
External Reset: See section 4: Wiring for information on resetting Totalizer #1 remotely from up to 30 meters distance. NOTE: When
Total #1 is reset from an external switch, the display will not show totalizer #1 unless it has been set as the standard totalizer.
1 2
Signet Total Flow
ENTER
Signet Total Flow
ENTER
2 s
Signet Total Flow
ENTER
8 s
Signet Total Flow
ENTER
5 m
Signet Total Flow
ENTER
Totalizer #2 can be reset ONLY by entering the security code.
1. Press ENTER key for 2 seconds. (Display shows security key symbol and 0-0-0-0)
2. Set the security code in the fl ashing display and then press the ENTER key.
3. Press UP key one time. (Display shows "tot2 reset")
4. Press RIGHT ARROW key. The totalizer value will begin fl ashing.
The totalizer will automatically reset to 00000000 in 8 seconds.
While the display is fl ashing, you can cancel the reset by pressing UP and DOWN keys together.
5. Press UP and DOWN keys together to return to normal operation.
1
2
3
Signet Total Flow
ENTER
Signet Total Flow
ENTER
2 s
Signet Total Flow
ENTER
Enter Security code
4
5
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Signet Total Flow
ENTER
8 s
Signet Total Flow
ENTER
To conserve battery life, totalizer values are stored in the memory every 12 hours. If both batteries are removed from the unit, the totalizers retain the last saved values, so the unit may lose several hours of data.
To prevent this loss, enter the security code, then enter any menu item and induce a "STORING" message.
Whenever the 8150 stores a setting, it also stores all current totalizer data:
1. Enter the security code.
2. Press the UP key to scroll to the last item in the menu (DEFAULT TOTALIZER)
3. Press the RIGHT key to enter the edit mode (fl ashing display mode)
4. Press the ENTER key to retain the current settings.
5. Press the UP and DOWN keys simultaneously to initiate the "Storing" function.
The batteries can now be removed and replaced without losing any totals.
8 8150 Flow Totalizer
The AutoCAL feature allows theTotalizer to be adjusted to match the fl ow rate to any external reference.
• Flow in the pipe should be as stable as possible for best results.
• If the fl ow rate display is erratic, set the SPEED (section 14) to 120 seconds during the Auto CAL procedure.
• The timebase on the reference meter must be the same as the 8150 Totalizer.
Change the fl ow rate from 60 GPM to 70 GPM using AutoCAL.
1. Hold the ENTER key for 2 seconds, then enter the SECURITY CODE.
Auto CAL is the fi rst item in the menu.
2. Press the RIGHT key to select the Auto CAL function.
The display will show Auto CAL and the current fl ow rate will be fl ashing.
3. Press the RIGHT key again to change the fl ow rate. The display shows "Set Flo" and the fi rst digit of the fl ow rate will begin fl ashing.
5. Press the RIGHT key to advance the fl ashing element to the "6".
5. Press the UP key one time to change the "6" to "7".
6. Press the ENTER key to complete the automatic calibration process.
The display shows a new K-factor with the fi rst digit fl ashing. This K-factor is based on the change in fl ow rate.
7. Press the ENTER key again to accept the new value.
NOTE: If the display shows "ERR SetFlo" the procedure was unsuccessful because the calculated K-factor is less than 0.001 or greater than 999999. Verify the fl ow rate and start the Auto CAL procedure from step 1.
8. Press UP and DOWN keys together to store the new value in the memory.
The display will show "storing" for a few seconds, then return to normal operation.
1
2
3
Signet Total Flow
ENTER
4
2 s
Signet Total Flow
ENTER
Enter Security code
5 6
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Signet Total Flow
ENTER
8150 Flow Totalizer
7
8
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Signet Total Flow
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Signet Total Flow
ENTER
9
10. Flow K-factor
The K-factor is the number of pulses generated by the fl ow sensor for each measure of water that moves past the sensor.
Your fl ow sensor manual contains k-factor data in terms of U.S. Gallons and Liters.
Locate the K-factor that matches your pipe size material.
If necessary, you can convert the K-factor into other units of measure. The minimum K-factor value is 0.001, maximum value is 999999.
Example: Change the Flow K-factor from 060.000 to 095.000
1. Hold the ENTER key for 2 seconds, then enter the SECURITY CODE. (factory default is 0-0-0-0)
The display shows the fi rst item in the menu (AutoCAL).
2. Press the DOWN key to scroll to the Flow K-factor. (the display shows the current K-factor setting)
3. Press the RIGHT key to select the Flow K-factor for editing. (The fi rst element of the K-factor will begin fl ashing.)
4. Press the RIGHT key 1 time to advance the fl ashing element to the "6".
5. Press the UP key three times to change the "6" to "9".
6. Press the RIGHT key to advance the fl ashing element to the "0."
7. Press the DOWN key fi ve times to change the "0" to "5".
8. Press the ENTER key to return to the CALIBRATE menu.
9. Press UP and DOWN keys together to store the new value and return to normal operation.
3
1
Signet Total Flow
ENTER
*
Signet Total Flow
ENTER
4
Signet Total Flow
ENTER
2 s
2
5
Signet Total Flow
ENTER
Enter Security code
**
6
*
Signet Total Flow
ENTER
7
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Signet Total Flow
ENTER
8
Signet Total Flow
ENTER
9
**
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Signet Total Flow
ENTER
10
*
As long as any element is fl ashing, you can abort the change and return to the original value by pressing UP and DOWN keys simultaneously.
Finished Editing?
**
Press the UP and DOWN keys simultaneously from the main menu to return to normal operation.
8150 Flow Totalizer
11. Total K-factor
The TOTAL K-factor is a multiple of the FLOW K-factor. Use it to program the incremental count size of the totalizer.
For example, if the fl ow RATE registers in Litres per minute, the totalizer may be set to 1 (factory standard), so it counts in 1-Litre increments, or it may be set to 1000, so it counts in 1Kilolitre (1m 3 ) increments.
By converting the Flow K-factor, the totalizer can also be set to count in other engineering units.
See sec. 17: "Flow and Total K-factor selection" for additional information about Total K-factor adjustments.
Example: Change the totalizer from 1 kiloLitre increments to count in 10-kiloLitre increments.
1. Hold the ENTER key for 2 seconds, then enter the SECURITY CODE.
The display shows the fi rst item in the menu, AutoCAL.
2. Press the DOWN key two times to scroll to the Total K-factor.
3. Press the RIGHT key to select the
1
Signet Total Flow
Total K-factor for editing.
The fi rst element of the Total Kfactor will begin fl ashing.
ENTER
4. Press the RIGHT key six times to advance the fl ashing element to the decimal point.
5. Press the DOWN key one time to move the decimal point one position to the right.
6. Press the ENTER key to return to the menu.
7. Press UP and DOWN keys together to exit the menu and return to normal operation.
The display shows "Storing" for a few seconds, then returns to the normal operating display.
2
Signet Total Flow
ENTER
5
Signet Total Flow
ENTER
2 s
3
Signet Total Flow
ENTER
Signet Total Flow
Signet Total Flow
ENTER
ENTER
4
Signet Total Flow
ENTER
6
Enter Security code
11.1 Adjusting the Flow K-factor
If the Totalizer yields a consistent error, make corrections by either using the AutoCal function (section 9) or by manually adjusting the Flow K-factor by the percentage of error.
A smaller K-factor increases the fl owrate, while larger K-factors reduce the fl ow rate.
7
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Example:
• The Flow K-factor is set at 480.19 pulses per Gallon.
• The totalizer registers 10 Gallons when the actual volume is known to be 11 Gallons.
• The error is 1 Gallon divided by 10 Gallons , or -10%. (The totalizer is counting 10% low, and the fl ow rate is reading 10% slow.)
• Reduce the Flow K-factor by 10%: 480.19 - 10% = 432.17.
• Change the Flow K-factor to 432 pulses per Gallon.
The result: The totalizer must count 10% fewer pulses from the fl ow sensor to register one Gallon, so both the totalizer and the fl ow rate will increase by 10%.
8150 Flow Totalizer 11
12. Time Base
Select the timebase for the fl ow rate. The available selections are seconds, minutes, hours or days.
Example: Change the Timebase from MINUTES (factory standard) to DAYS
1. Hold the ENTER key for 2 seconds, then enter the SECURITY CODE.
The display shows the fi rst item in the CALIBRATE menu, AutoCAL.
2. Press the DOWN key three times to scroll to the Timebase.
3. Press the RIGHT key to select the Timebase for editing.
4. Press the UP key two time to scroll from MIN to DAY.
5. Press the ENTER key to return to the menu.
6. Press UP and DOWN keys together to exit the menu and return to normal operation.
The display shows "Storing" for a few seconds, then returns to the normal operating display.
1
2
**
Signet Total Flow
ENTER
2 s
3
Signet Total Flow
ENTER
Enter Security code
4
*
Signet Total Flow
ENTER
5
*
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Signet Total Flow
ENTER
**
6
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Signet Total Flow
ENTER
12
*
As long as any element is fl ashing, you can abort the change and return to the original value by pressing UP and DOWN keys simultaneously.
Finished Editing?
**
Press the UP and DOWN keys simultaneously from the main menu to return to normal operation.
8150 Flow Totalizer
13. Decimal point for Flow display
Select the maximum decimal resolution for the fl ow rate display. The available selections are hundredths (xx.xx) tenths (xxx.x) or whole numbers only (xxxx.) The decimal will auto-range down to this setting.
• If the decimal is set to whole numbers, the fl ow rate display will not auto-range.
• If the decimal is set to tenths, the fl ow rate display will show tenths up to 999.9, then the auto-range will switch to whole numbers (1000-to 9999.)
• If the decimal is set to hundredths, the fl ow rate display will show hundredths up to 99.99, then tenths from 100.1 to 999.9, then whole numbers to 9999.
Available Display
Selections
hundredths (XX.XX) tenths (XXX.X) whole numbers (XXXX.)
Your
Flow rate
10.55
10.55
10.55
will read on display as:
10.55
10.6
11
Example: Change the maximum decimal display from
from hundredths to tenths.
hundredths to tenths:
5. Press the ENTER key to return to the menu.
1. Hold the ENTER key for 2 seconds, then enter the SECURITY
The decimal will stop fl ashing.
CODE.
The display shows the fi rst item in the menu, AutoCAL.
return to normal operation.
2. Press the DOWN key four times to scroll to the Decimal setting.
The display shows "Storing" for a few seconds, then returns
The display shows four dashes and the current decimal setting.
to the normal operating display.
3. Press the RIGHT key to select the decimal for editing.
6. Press UP and DOWN keys together to exit the menu and
The decimal point will begin to fl ash.
4. Press the DOWN key one time to move the fl ashing decimal
1
2
Signet Total Flow
ENTER
Signet Total Flow
ENTER
2 s
3
Signet Total Flow
ENTER
4
Signet Total Flow
ENTER
Enter Security code
5
*
Signet Total Flow
ENTER
Signet Total Flow
ENTER
6
**
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Signet Total Flow
ENTER
*
As long as any element is fl ashing, you can abort the change and return to the original value by pressing UP and DOWN keys simultaneously.
8150 Flow Totalizer
Finished Editing?
**
Press the UP and DOWN keys simultaneously from the main menu to return to normal operation.
13
14. Speed
SPEED averaging serves to smooth out fl uctuations in the fl ow rate that may be caused by inadequate straight pipe runs after pumps, valves, and elbows in the pipe. The selections are 0, 7, 15, 30, 60 and 120 seconds. The factory standard setting is 30 seconds.
• Use faster (0-30 s) averaging for well-established, stable fl ow conditions.
• Use slower (60-120 s) averaging if the fl ow conditions are unstable.
Note: While the SPEED setting helps to smooth out the fl uctuations caused by piping conditions, it also causes a delay in showing actual changes in fl ow rate. The SENSITIVITY function (section 15) is designed to help offset this effect.
Example: Change the SPEED setting from 60 seconds to 30 seconds.
1. Hold the ENTER key for 2 seconds, then enter the SECURITY CODE.
The display shows the fi rst item in the CALIBRATE menu, AutoCAL.
2. Press the DOWN key fi ve times to scroll to DISP SPEED.
The display shows DISP SPEED, the "sec" annunciator, and the current speed setting.
3. Press the RIGHT key to select the Display speed for editing.
The current speed selection begins fl ashing.
4. Press the DOWN key one time to scroll from 60 seconds to 30 seconds.
5. Press the ENTER key to return to the menu.
6. Press UP and DOWN keys together to exit the menu and return to normal operation.
The display shows "Storing" for a few seconds, then returns to the normal operating display.
1
2
Signet Total Flow
ENTER
2 s
3
Signet Total Flow
ENTER
Enter security code
4
*
5
**
6
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Signet Total Flow
ENTER
14
*
As long as any element is fl ashing, you can abort the change and return to the original value by pressing UP and DOWN keys simultaneously.
Finished Editing?
**
Press the UP and DOWN keys simultaneously from the main menu to return to normal operation.
8150 Flow Totalizer
15. Sensitivity
The SENSITIVITY setting determines how the 8150 responds to sudden surges in the fl ow rate. It "overrides" the SPEED function just long enough to allow an actual change in fl ow rate to be displayed, then resumes the averaging. The result is a smooth fl ow display and a quick response to large shifts in the fl ow rate.
No SPEED, no SENSITIVITY
With SPEED averaging set to 0 (zero) and with SENSITIVITY set to zero, the fl ow rate may be very unstable. This line represents the actual output of the fl ow sensor as it responds to unstable fl ow conditions in the pipe.
SPEED only
With SPEED set to 60 seconds and SENSITIVITY still set to zero the fl ow rate is stabilized, but a sharp change in fl ow rate is not represented for 60 seconds or longer. (dotted green line).
SPEED and SENSITIVITY
With SPEED at 60 seconds and SENSITIVITY set to 6, the fl ow rate is stabilized, while the sudden shift in fl ow is refl ected very quickly. (dotted blue line)
2 s 10 s 20 s 30 s 40 s 50 s 60 s 70 s
NOTE: The SENSITIVITY function is ineffective if the SPEED function is set to zero (seconds).
Example: Change the SENSITIVITY from 5 to 8
1. Hold the ENTER key for 2 seconds, then enter the SECURITY CODE.
The display shows the fi rst item in the menu, AutoCAL.
2. Press the UP key once to scroll to SENSITIVITY.
The display shows DISP SENS and the current sensitivity setting.
3. Press the RIGHT key to select the SENSITIVITY for editing.
The current SENSITIVITY setting begins fl ashing.
4. Press the UP key three times to scroll from 5 to 8.
5. Press the ENTER key to return to the menu.
6. Press UP and DOWN keys together to exit the menu and return to normal operation.
The display shows "Storing" for a few seconds, then returns to the normal operating display.
1
2
Signet Total Flow
ENTER
3
2 s
Signet Total Flow
ENTER
Enter Security code
4
5
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Signet Total Flow
ENTER
6
Signet Total Flow
ENTER
Signet Total Flow
ENTER
Signet Total Flow
ENTER
8150 Flow Totalizer 15
16. Troubleshooting
Display Condition
Probable Cause
Batteries are dead or missing
Suggested Solutions
Replace both batteries.
The fl ow rate is greater than “9999”
1. Reduce the fl ow rate.
2. Change the Timebase to a smaller value.
(Example: Change from “Day” to “Hr”.)
3. Change the fl ow units to a larger measure.
(Example: Change from “Liters” to “Gallons”.).
NOTE: If the Flow K-factor is changed, be sure to make a corresponding change to the TOTAL K-factor.
8150 is not receiving a signal from the fl ow sensor.
1. There is no fl ow in the pipe.
2. Flow sensor is not turning due to blockage or damage.
3. Sensor wiring is loose or incorrect.
In AutoCal, the calculated K-factor is outside the range of the8150.
(less than 0.001 or greater than 99999)
The fl ow rate display is erratic and non-linear
Usually caused by inadequate straight pipe run upstream of sensor.
Press RIGHT key to start Auto CAL procedure again.
Make sure that the fl ow rate entered is accurate.
1. Correct piping layout to provide more straight pipe upstream of sensor.
2. Set the SPEED to higher setting to average out the fl uctuations caused by piping conditions. (see Speed, section 14)
Both batteries are too depleted to safely store settings.
Replace battery #1, then replace battery #2.
17. Flow and Total K-factor selection
Pages 17-19 provide K-factors for the Signet
515, 525, and 2517 fl ow sensors. Use this table to convert the K-factor to other units of measure, and to set the Total K-factor.
NOTE:
• The maximum K-factor is 999999.
• The minimum K-factor is 0.001.
16
If you want the
FLOW RATE to read in:
Liters
Liters
Liters cubic meters cubic meters
Kiloliters
KiloLiters
MegaLiters
U.S. gallons
U.S. gallons
U.S. gallons
U.S. gallons
U.S. gallons
U.S. gallons
Acre-Inches
Acre-Inches
Acre feet
Acre feet cubic feet
and you want the TO-
TALIZER to count in:
Liters
Kiloliters cubic meters cubic meters
MegaLiters
Kiloliters
MegaLiters
MegaLiters
U.S. gallons
U.S. gallons x 1000 cubic feet acre inches
Acre feet
Kiloliters
Acre-Inches
Acre feet
Acre feet
Acre-Inches cubic feet
Set the Flow
K-factor to:
K(Liter)
K(Liter)
K(Liter)
K(Liter) x 1000
K(Liter) x 1000
K(Liter) x 1000
K(Liter) x 1000
K(Liter) x 1 000 000
K(gal)
K(gal)
K(gal)
K(gal)
K(gal)
K(gal)
K(gal) x 27154
K(gal) x 27154
K(gal) x 325848
K(gal) x 325848
K(gal) x 7.4805
and set the Total
K-factor to:
1
1000
1000
1
1000
1
1000
1
1
1000
7.4805
27154
325848
264.2
1
12
1
0.083
1
8150 Flow Totalizer
18. K-factor Charts
18.1 515 Paddlewheel Flow Sensor
The following calibration data is reprinted from the instruction manual for the Signet 515 Flow sensor for your convenience.
PIPE
SIZE
(IN.)
FITTING
515/8510-XX
U.S. GAL LITERS
SCH 80 PVC TEES FOR SCH 80 PVC PIPE
1/2 PV8T005 480.19
126.87
3/4
1
1-1/4
1-1/2
2
PV8T007
PV8T010
PV8T012
PV8T015
PV8T020
257.72
174.67
83.390
58.580
32.480
68.090
46.148
22.032
15.477
8.5812
2-1/2
3
PV8T025
PV8T030
21.833
13.541
5.7683
3.5775
4 PV8T040 7.6258
2.0147
SCH 80 CPVC TEES FOR SCH 80 CPVC PIPE
1/2 CPV8T005 480.19
126.87
3/4
1
1-1/4
1-1/2
CPV8T007
CPV8T010
CPV8T012
CPV8T015
257.72
174.67
83.390
58.580
68.090
46.148
22.032
15.477
SCH 80 PVC SADDLES FOR SCH 80 PVC PIPE
2 PV8S020 32.480
8.5812
2-1/2
3
4
PV8S025
PV8S030
PV8S040
21.833
13.541
7.6258
5.7683
3.5775
2.0147
6
8
PV8S060
PV8S080
10 PV8S100
12 PV8S120
4.1623
2.3705
1.5300
1.0600
1.0997
0.6263
0.4042
0.2801
SCH 80 PVC SADDLE ON SCH 40 PVC PIPE
2
2-1/2
3
4
6
PV8S020
PV8S025
PV8S030
PV8S040
PV8S060
27.350
18.874
12.638
6.7282
3.7297
7.2259
4.9866
3.3389
1.7776
0.9854
8 PV8S080
10 PV8S100
2.1527
1.3500
0.5688
0.3567
12 PV8S120 0.9600
0.2536
PP CLAMP-ON SADDLE ON SCH 80 PP PIPE
10 PPS100
12 PPS120
1.5300
1.0600
0.4042
0.2801
PP CLAMP-ON SADDLE ON SCH 40 PP PIPE
10 PPS100 1.3500
0.3567
12 PPS120 0.9600
0.2536
PIPE
SIZE
(IN.)
FITTING
515/8510-XX
U.S. GAL LITERS
CARBON STEEL TEES ON SCH 40 PIPE
1/2 CS4T005 370.20
97.808
3/4
1
1-1/4
1-1/2
2
CS4T007
CS4T010
CS4T012
CS4T015
CS4T020
212.06
141.14
60.655
45.350
26.767
56.027
37.289
16.025
11.982
7.0717
STAINLESS STEEL TEES ON SCH 40 PIPE
1/2
3/4
1
CR4T005
CR4T007
CR4T010
358.96
202.61
127.14
94.838
53.530
33.590
1-1/4
1-1/2
CR4T012
CR4T015
61.910
40.410
16.357
10.676
2 CR4T020 22.300
5.8917
GALVANIZED IRON TEES ON SCH 40 PIPE
1 IR4T010 104.54
27.619
1-1/4
1 1/2
IR4T012
IR4T015
62.979
46.688
2 IR4T020 29.459
BRONZE TEES ON SCH 40 PIPE
1 BR4T010 104.54
16.639
12.335
7.7832
27.619
1-1/4
1-1/2
BR4T012
BR4T015
62.979
46.688
16.639
12.335
2 BR4T020 29.459
7.7832
COPPER TEE FITTINGS ON COPPER PIPE
SCH K
1/2
3/4
1
CUKT005
CUKT007
CUKT010
443.21
212.16
127.18
117.10
56.052
33.600
1-1/4
1-1/2
CUKT012
CUKT015
88.218
56.962
23.307
15.049
2 CUKT020 29.370
7.7595
COPPER TEE FITTINGS ON COPPER PIPE
SCH L
1/2
3/4
1
CUKT005
CUKT007
CUKT010
414.41
191.09
119.84
109.49
50.485
31.662
1-1/4
1-1/2
2
CUKT012
CUKT015
CUKT020
85.451
55.160
28.605
22.576
14.573
7.5575
PIPE
SIZE
(IN.)
FITTING
515/8510-XX
U.S. GAL LITERS
STAINLESS STEEL WELDOLETS ON SCH 40
PIPE
2-1/2
3
4
CR4W025
CR4W030
CR4W040
18.800
12.170
6.9600
4.9670
3.2153
1.8388
5
6
8
10
12
CR4W050
CR4W060
CR4W080
CR4W100
CR4W120
5.2600
3.6900
2.1300
1.3500
0.9600
1.3897
0.9749
0.5627
0.3567
0.2536
CARBON STEEL WELDOLETS ON SCH 40
PIPE
2-1/2 CS4W025 18.800
4.9670
3
4
5
6
8
CS4W030
CS4W040
CS4W050
CS4W060
CS4W080
12.170
6.9600
5.2600
3.6900
2.1300
3.2153
1.8388
1.3897
0.9749
0.5627
10
12
CS4W100
CS4W120
1.3500
0.9600
0.3567
0.2536
COPPER/BRONZE BRAZOLETS ON SCH 40
PIPE
2-1/2 BR4B025
3 BR4B030
4 BR4B040
5 BR4B050
18.800
12.170
6.9600
5.2600
4.9670
3.2153
1.8388
1.3897
6 BR4B060
8 BR4B080
10 BR4B100
12 BR4B120
3.6900
2.1300
1.3500
0.9600
0.9749
0.5627
0.3567
0.2536
SCH 80 IRON SADDLES ON SCH 80 PIPE
2 IR8S020 32.360
8.5495
2-1/2 IR8S025
3 IR8S030
4 IR8S040
22.220
13.420
7.6600
5.8705
3.5456
2.0238
5 IR8S050
6 IR8S060
8 IR8S080
10 IR8S100
12 IR8S120
5.8600
4.0900
2.3300
1.5300
1.0600
1.5482
1.0806
0.6156
0.4042
0.2801
SCH 80 IRON SADDLE ON SCH 40 PIPE
2 IR8S020 26.820
7.0859
2-1/2 IR8S025
3 IR8S030
4 IR8S040
18.800
11.990
6.8500
4.9670
3.1678
1.8098
5 IR8S050
6 IR8S060
8 IR8S080
10 IR8S100
12 IR8S120
5.3300
3.7600
2.1300
1.3500
0.9600
1.4082
0.9934
0.5627
0.3567
0.2536
8150 Flow Totalizer 17
18.1 515 Paddlewheel Flow Sensor (continued)
PIPE
SIZE
FITTING
515/8510-XX
U.S.
GAL
LITERS
POLYPROPYLENE FITTINGS (DIN/ISO AND
BS AND ANSI)
DN 15
DN 20
DN 25
DN 32
DN 40
PPMT005
PPMT007
PPMT010
PPMT012
PPMT015
481.55
277.09
141.18
83.540
51.265
127.23
73.207
37.300
22.071
13.544
DN 50
DN 65
DN 80
DN 100
DN 125
PPMT020
PPMT025
PPMT030
PPMT040
PPMT050
29.596
20.658
13.330
8.7077
5.0667
7.8193
5.4579
3.5218
2.3006
1.3386
DN 150
DN 200
PPMT060
PPMT080
3.6892
2.0398
0.9747
0.5389
PVDF FITTINGS (DIN/ISO AND BS AND ANSI)
DN 15 SFMT005 420.87
111.19
DN 20 SFMT007 228.15
60.277
DN 25
DN 32
DN 40
DN 50
DN 65
DN 80
DN 100
DN 125
DN 150
SFMT010
SFMT012
SFMT015
SFMT020
SFMT025
SFMT030
SFMT040
SFMT050
SFMT060
136.70
79.294
43.490
25.908
18.067
12.357
8.0599
4.4312
3.2271
DN 200 SFMT080 2.0360
0.5379
PVC FITTINGS (DIN/ISO) - EUROPE ONLY
DN 15
DN 20
DN 25
PVMT005
PVMT007
PVMT010
486.18
242.85
148.64
128.45
64.160
39.270
DN 32
DN 40
DN 50
DN 65
DN 80
PVMT012
PVMT015
PVMT020
PVMT025
PVMT030
85.125
51.855
29.750
17.487
12.491
22.490
13.700
7.8600
4.6200
3.3000
DN 100
DN 150
DN 200
PVMT040
PVMT060
PVMT080
8.1377
4.0878
2.0439
36.116
20.950
11.490
6.8450
4.7732
3.2648
2.1294
1.1707
0.8526
2.1500
1.0800
0.5400
18.2 525 Metalex Flow Sensor
The following data is reprinted from the Signet 525 Metalex Flow sensor manual for your convenience.
1 1/2 IN.
2 IN.
2 1/2 IN.
3 IN.
4 IN.
5 IN.
6 IN.
8 IN.
10 IN.
12 IN.
SCH 40S STAINLESS STEEL PIPE
PER ANSI B36.19
K-FACTOR K-FACTOR
PIPE PULSES/
U.S. GAL
PULSES/
LITER
SIZE
1/2 IN.
873.03
230.66
3/4 IN.
1 IN.
1 1/4 IN.
515.41
266.17
148.84
136.17
70.322
39.324
107.98
64.808
44.685
28.579
16.302
10.237
7.0057
3.9641
2.4690
1.6894
28.528
17.122
11.806
7.5506
4.3070
2.7046
1.8509
1.0473
0.6523
0.4463
18 8150 Flow Totalizer
18.3 2517 High Performance Flow Sensor
The following data is reprinted from the Signet 2517 High Performance Flow sensor manual for for your convenience.
SCH 40 WROUGHT STEEL PIPE
PER ANSI B36.10
K-FACTOR K-FACTOR
SCH 5S STAINLESS STEEL PIPE
PER ANSI B36.19
K-FACTOR K-FACTOR
“STD WROUGHT STEEL PIPE
PER ANSI B36.10”
K-FACTOR K-FACTOR
SCH 40S STAINLESS STEEL
PIPE PER ANSI B36.19
K-FACTOR K-FACTOR
18
20
22
24
10
12
14
16
4
5
6
8
PIPE
SIZE
1 1/2
2
2 1/2
3
3 1/2
2.6080
1.7610
1.4250
1.0590
0.8180
0.6460
*
0.4350
PULSES/
U.S. GAL
122.000
78.690
55.630
35.530
26.070
19.840
12.090
8.0410
4.3500
0.6890
0.4653
0.3765
0.2798
0.2161
0.1707
*
0.1149
PULSES/
LITER
32.232
20.790
14.697
9.3871
6.8877
5.2417
3.1942
2.1244
1.1493
PULSES/
U.S. GAL
104.200
67.160
46.060
29.790
22.060
16.890
10.6500
7.1160
3.8700
2.3570
1.6060
1.2980
0.9620
0.7400
0.5900
0.4790
0.3990
5
6
8
10
12
14
16
18
20
22
24
PIPE
SIZE
1 1/2
2
2 1/2
3
3 1/2
4
2.8137
1.8801
1.0225
0.6227
0.4243
0.3429
0.2542
0.1955
0.1559
0.1266
0.1054
PULSES/
LITER
27.5297
17.7437
12.1691
7.8705
5.8283
4.4624
2.6080
1.7400
1.3950
1.0220
0.7800
0.6150
0.4970
0.4110
PULSES/
U.S. GAL
122.000
78.690
55.630
35.530
26.070
19.840
12.090
8.0410
4.3500
18
20
22
24
10
12
14
16
4
5
6
8
PIPE
SIZE
1 1/2
2
2 1/2
3
3 1/2
0.6890
0.4597
0.3686
0.2700
0.2061
0.1625
0.1313
0.1086
PULSES/
LITER
32.2325
20.7900
14.6975
9.3871
6.8877
5.2417
3.1942
2.1244
1.1493
*
*
*
*
2.6080
1.7400
*
*
PULSES/
U.S. GAL
122.000
78.690
55.630
35.530
26.070
19.840
12.090
8.0410
4.3500
18
20
22
24
10
12
14
16
4
5
6
8
PIPE
SIZE
1 1/2
2
2 1/2
3
3 1/2
*
*
*
*
0.6890
0.4597
*
*
PULSES/
LITER
32.2325
20.7900
14.6975
9.3871
6.8877
5.2417
3.1942
2.1244
1.1493
SCH 80 WROUGHT STEEL PIPE
PER ANSI B36.10
K-FACTOR K-FACTOR
PULSES/
U.S. GAL
136.100
88.590
62.810
39.990
29.220
22.160
13.420
9.0160
4.8190
2.8970
1.9620
1.5890
1.1750
0.9040
0.7160
0.5820
0.4820
12
14
16
18
3 1/2
4
5
6
8
10
PIPE
SIZE
1 1/2
2
2 1/2
3
20
22
24
PULSES/
LITER
35.9577
23.4055
16.5945
10.5654
7.7199
5.8547
3.5456
2.3820
1.2732
0.7654
0.5184
0.4198
0.3104
0.2388
0.1892
0.1538
0.1273
Schedule 40 Plastic pipe per
ASTM-D-1785
K-FACTOR K-FACTOR
PIPE
SIZE
1 1/2
2
2 1/2
3
3 1/2
4
5
6
8
PULSES/
U.S. GAL
124.400
80.140
56.730
36.180
26.500
20.140
12.250
8.1430
4.3980
10
12
2.6340
1.7770
8150 Flow Totalizer
PULSES/
LITER
32.8666
21.1731
14.9881
9.5588
7.0013
5.3210
3.2365
2.1514
1.1620
0.6959
0.4695
SCH 10S STAINLESS STEEL
PIPE PER ANSI B36.19
K-FACTOR K-FACTOR
2.3880
1.6200
1.3110
0.9680
0.7440
0.5930
0.4820
0.4020
PULSES/
U.S. GAL
113.600
72.560
48.750
31.250
23.010
17.540
10.8700
7.2410
3.9520
18
20
22
24
10
12
14
16
PIPE
SIZE
1 1/2
2
2 1/2
3
3 1/2
4
5
6
8
0.6309
0.4280
0.3464
0.2557
0.1966
0.1567
0.1273
0.1062
PULSES/
LITER
30.0132
19.1704
12.8798
8.2563
6.0793
4.6341
2.8719
1.9131
1.0441
“Schedule 80 Plastic pipe per
ASTM-D-1785”
K-FACTOR K-FACTOR
4
5
6
8
PIPE
SIZE
1 1/2
2
2 1/2
3
3 1/2
10
12
PULSES/
U.S. GAL
139.400
90.790
64.610
41.050
29.940
22.660
13.700
9.1990
4.9060
2.9450
1.9930
PULSES/
LITER
36.8296
23.9868
17.0700
10.8454
7.9102
5.9868
3.6196
2.4304
1.2962
0.7781
0.5266
“XS WROUGHT STEEL
PIPE PER ANSI B36.10”
K-FACTOR K-FACTOR
13.420
9.0160
4.8190
2.7730
1.8240
1.4550
1.0590
0.8050
PULSES/
U.S. GAL
136.100
88.590
62.810
39.990
29.220
22.160
0.6320
0.5100
0.4200
10
12
14
16
18
5
6
8
PIPE
SIZE
1 1/2
2
2 1/2
3
3 1/2
4
20
22
24
3.5456
2.3820
1.2732
0.7326
0.4819
0.3844
0.2798
0.2127
PULSES/
LITER
35.9577
23.4055
16.5945
10.5654
7.7199
5.8547
0.1670
0.1347
0.1110
SCH 80S STAINLESS STEEL
PIPE PER ANSI B36.19
K-FACTOR K-FACTOR
13.420
9.0160
4.8190
2.7730
1.8240
*
*
*
PULSES/
U.S. GAL
136.100
88.590
62.810
39.990
29.220
22.160
*
*
*
10
12
14
16
18
5
6
8
PIPE
SIZE
1 1/2
2
2 1/2
3
3 1/2
4
20
22
24
3.5456
2.3820
1.2732
0.7326
0.4819
*
*
*
PULSES/
LITER
35.9577
23.4055
16.5945
10.5654
7.7199
5.8547
*
*
*
19
19. Ordering Information
Mfr. Part No. Code
3-8150-P0
3-8150-P1
3-8150-T0
3-8150-V0
159 000 931
159 000 932
159 001 011
159 001 012
Parts and Accessories
Mounting
3-8050 159 000 184
3-0000.596
3-5000.598
3-8050.395
3-9000.392
159 000 641
198 840 225
159 000 186
159 000 368
3-9000.392-1 159 000 839
3-9000.392-2 159 000 841
3-8050.392
7400-0011
5523-0222
159 000 640
159 000 935
159 000 392
Description
Totalizer, Mount
Flow Totalizer system, Integral, for 0.5 to 4 in. pipes, PP housing, Blk PVDF rotor, Titanium pin
Flow Totalizer system, Integral, for 0.5 to 8 in. pipes, PP housing, Blk PVDF rotor, Titanium pin
Flow Totalizer system, Integral, for 0.5 to 4 in. pipes, natural PVDF housing, rotor and pin
Flow Totalizer system, Integral, for 0.5 to 4 in. pipes, natural PVDF housing and rotor, Hastelloy pin
Universal mounting kit
Heavy duty wall mount bracket (for panel mount only)
Surface mount bracket
Splashproof rear cover for panel mount totalizer
Liquid tight connector kit (includes 3 connectors)
Liquid tight connector, NPT (1 connector)
Liquid tight connector, PG 13.5 (1 connector)
Model 200 retrofi t adaptor
Lithium battery, 3.6V, AA size
Cable, two conductor shielded, 22 AWG
Replacement parts for integral mount units
3-8051 159 000 187 Flow integral mounting kit, NPT replacement)
3-8510-P0
3-8510-PI
198 864 504
198 864 505
Sensor for 0.5 to 4 in. pipes, Polypropylene housing, titanium pin, Blk PVDF rotor
Sensor for 5 to 8 in. pipes, Polypropylene body
3-8510-T0
3-8510-V0
159 000 622
198 864 506
Sensor for 0.5 to 4 in. pipes, natural PVDF housing, rotor and pin
Sensor for 0.5 to 4 in. pipes, natural PVDF housing and rotor, Hastelloy pin
Signet Total Flow
ENTER
Flow Totalizer
Panel Mount
3-8150-1P
3-8050
Universal mounting kit
Integral System
3-8150-PO
3-8150-P1
3-8150-TO
3-8150-VO
Terminal Cover
4-3111
Flow
Totalizer
(3-8150-1)
Integral adapter Kit
(3-8051)
Integral
Flow Sensor
(3-8510-XX)
George Fischer Signet, Inc. 3401 Aerojet Avenue, El Monte, CA 91731-2882 U.S.A. • Tel. (626) 571-2770 • Fax (626) 573-2057
For Worldwide Sales and Service, visit our website: www.gfsignet.com • Or call (in the U.S.): (800) 854-4090
3-8150.090-1 Rev. E 2/06 English © George Fischer Signet, Inc. 2001 Printed in U.S.A. on recycled paper

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Provides uninterrupted flow and total volume information for 4 years and beyond
- Easy setup and display selection with 4-button keypad
- User selectable security access
- Flow rate display from 0.001 to 9999 engineering units
- Three totalizers: permanent, resettable, and resettable with security code
- Displays elapsed time between operating periods
- Integral mount and panel mount options
- 3.6 V Lithium batteries last 4 years nominal in most applications
- Non-volatile memory stores all programming and totalizer values even when batteries are removed