Installation and operation manual
Drying cabinet TS 62
Thank you for choosing this drying cabinet TS 62 from PODAB.
We hope that it will be of great use for you and ask you kindly to read the instructions carefully.
IMPORTANT!
FOR YOUR SAFETY, the information in this manual must be followed to prevent property damage and personal injury.
NOTE: The paragraphs marked “WARNING” and “CAUTION” appearing in this manual are not meant to cover all possible conditions and situations that may occur. It is very important that water and electricity are handled with great care and respect, by both installation technicians and end users.
©PODAB 2011 2
Contents
Safety regulations
Important safety instructions
Specification
Dimensions
Technical information
Assembly instructions
Installation of the cabinet
Step 1: Put the cabinet in place
Step 2: Fasten the cabinet to the wall
Step 3: Connect the cabinet to the ventilation channel
Step 4: Connect the drying cabinet to the main switch
Step 5: Control that the heating relay is working
Turn the hanging frame
Requirements for ventilation
Ventilation channel – choice of material
Requirements for incoming air
Ventilation channel – design
Evacuated amount of air and pressure fall
User manual
Manual programme mode
Automatic programme mode
Maintenance
Notes
27
27
27
29
25
25
25
25
26
30
20
20
21
21
22
22
23
6
6
7
4
5
8
3
©PODAB 2011
Safety regulations
Throughout this manual you will find text warnings in text boxes: “WARNING” and “CAUTION”. In these boxes you’ll find the safety measurements you’ll have to take; end user, service staff or installation staff.
CAUTION
Indicates hazardous situation that, if not avoided, could cause minor personal injury or property damage.
WARNING
Indicates hazardous situation that, if not avoided, could cause severe personal injury.
You will also find precautions marked: IMPORTANT and NOTE.
These are followed by information of what should be considered.
IMPORTANT: to inform the reader of special steps that must be taken in order to prevent injuries on the cabinet.
NOTE: to inform what is important to know, but it cannot cause personal injuries or injury on the cabinet.
©PODAB 2011 4
Important safety instructions
WARNING
To minimize the risk of fire, electrical shock, personal injuries or death when the cabinet is in use the following precautions must be followed:
1.
2.
3.
4.
5.
6.
7.
Read the instruction before using the drying cabinet.
Follow the instructions in step 4 for proper grounding.
Never dry textiles that have been washed, dipped or exposed to fire dangerous substances or fluids.
Never add fire dangerous or explosives substances in the cabinet.
The cabinet is not a toy. Look after the children who are around the cabinet.
Never connect the cabinet with an extension cable.
Only use the cabinet for what it is designed for: drying clothes.
8.
9.
Always turn off the main switch before performing any service on the cabinet. Only authorized service technicians should perform service.
Always follow the installation manual. The electrical connections must be done by authorized personnel.
10. Keep after the cabinet. If it is exposed for violence there is a risk that certain security functions will stop working.
Please contact your nearest service partner if you are unsure of the cabinet’s status.
11. If the electrical cable is damaged, it must immediately be changed by a person with electrical authorization.
12. The doors shall always be shut when the cabinet is in use.
Don’t try to manipulate the lock of the doors. It can lead to personal injuries. If the cabinet doesn’t stop when the doors are opened during the drying phase, call for service.
The cabinet shall not be used if the drying program is active when the doors are open!
13. Look after the area around the evacuating pipe so it is clean from dust and dirt.
14. To get the best drying result, follow the garments washing
& drying advice.
15. Never use the cabinet if any panel is broken or removed.
16. Never use the cabinet if any parts are broken or if the inside is broken.
17. Never try to manipulate or connect past any safety functions.
18. If the cabinet isn’t assembled after the manufacturer’s instructions, there is a risk that the cabinet can cause personal injuries or injuries on property.
5
©PODAB 2011
Specification
Dimensions
1200
A
B
469
640
A = Electrical connection
B= Exhaust
©PODAB 2011
1855
6
Technical information
Loading capacity, kg (lb)
Drying capacity, g/min (oz/min)*
Hanging length, m (ft)
Drying time, min*
Evacuated air, max, m³/h (ft³/h)
Exhaust
ø, mm (in)
Heating effect, kW
Total effect, kW up to 8 (17,6)
91 (3,2)
16 (52,5)
35
340 (12007)
125 (4,92)
6,0
6,3
Energy consumption, kWh/kg (kWh/lb)*
Part No
0,55 (0,48)
131025
*Drying of 6 kg (13,2 lb) cotton (dry weight), washed and high-spinned to 53% residual moisture. The cabinet works another 15 minutes with cool-down after the textiles are dry.
7
©PODAB 2011
Assembly instructions
Tools
You need the following tools to easily install the drying cabinet:
(If the cabinet is already assembled please go to page 20)
• Cordless screwdriver
• Wrench
• Hex key 3 and 5 mm
• Level
• Torx screwdriver bit no. 25
1
4x
2
©PODAB 2011 8
4x
3
4
5
3x
9
4x
©PODAB 2011
6
7
Note!
Only for cabinets with hanging frame.
©PODAB 2011 10
7x
10x
8
9
2x
10
Note! Only for cabinets with hanging frame
MAX
11
3x
4x
1x
1x
©PODAB 2011
11
24x
12
©PODAB 2011 12
4x
13
14
Note! Only for cabinets with hanging frame
1x
1x
1x
1x
4x
13
©PODAB 2011
15
16
17
©PODAB 2011 14
4x
18
1x
19
1x
20
15
8x
©PODAB 2011
21
Connect the cables
22
LCD
23
Keypad
The side with hole pattern to the left.
Lights
Door switch
4x
©PODAB 2011 16
24
2x
25
Note! Only for cabinets with hanging frame
B
C
A
D
17
©PODAB 2011
26
Note! Only for cabinets with hanging frame
A
B
A
A
B
B
27
Note! Only for cabinets with single rack bar
8x
28
Note! Only for cabinets with single rack bar
4x
©PODAB 2011 18
29
Note! Only for cabinets with single rack bar
4x
30
19
©PODAB 2011
Installation of the cabinet
Step 1: Put the cabinet in place
Place the cabinet with enough space in front of the cabinet and on the sides to be able to open the doors.
The feet of the cabinet can be adjusted from the inside with the help of a Hex key. The feet must stand free on the floor and have an even weight distribution. Use a leveler and control that the cabinet is leveled; horizontally and vertically.
NOTE: We recommend that the cabinet is installed on a firm and leveled floor.
Please observe that the front panel (on the top) must have at least 175 mm free space above, in order to take off the top to perform service.
Narrow spaces
If the cabinet must be transported through narrow spaces, we recommend that you take off the doors first. It will simplify the handling and reduces the risk for damages on the doors.
Demounting of the top
To simplify the transport of the cabinet, the top can be demounted, see the instructions below.
1. Loosen the two screws which hold the front panel of the top.
3.
4.
Disconnect the cables (connected to the LCD and maneuver panel) from the mother board. Loosen the bulb’s connection plinth marked “Light”.
From the inside of the cabinet, loosen the protection plate (8 screws).
5. Loosen both service hatches which cover the fans. 1 screw on each service hatch.
2. Push the panel upwards.
6. Lift the top off.
CAUTION
There must be two persons to lift the top in a safe way. Don’t try to do it on your own, the weight is 30 kg!
©PODAB 2011 20
Step 2: Fasten the cabinet to the wall
Use the stoppers, screws and washers to secure the cabinet through the back plates. Fastening holes are pre-drilled in the back plates.
Step 3: Connect the cabinet to the ventilation channel
For further instructions, se page 25: Requirements for ventilation.
• Do not use ventilation channels made of plastic or foil.
• Place the cabinet so that the ventilation channel is as short
• as possible.
Make sure that the ventilation channel is cleaned when a
• new cabinet is installed.
Use a 125 mm rigid or flexible metal duct to the evacuation
• connection.
If you use rigid ducts, it is important that the male connector of the ventilation tube on each section follows the air direction.
• The construction shall be as straight as possible.
• Always isolate ducts that go through non-isolated areas.
The condensation makes dust and dirt get stuck in the channel.
NOTE: If the cabinet is not connected according to these recommendations, the warranty is no longer valid.
NOTE: Please control that the cabinet is leveled and cannot be tilted.
21
©PODAB 2011
Step 4: Connect the drying cabinet to the main switch
To prevent that fire and electric shock appear, the cabinet MUST be connected according to the color codes on the cables. Only an authorized electrician is allowed to install the electrical connection. The cabinet is prepared for one of the following electrical connections depending on specification:
• 400 V, 3-N, 50 Hz (standard)
• 208-240 V, 3~N, 60 Hz
• 220 V, 3~N, 50 Hz
Step 5: Control that the heating relay is working
Shut the doors and start the cabinet, after about 3 seconds you can hear when the heat relays hit. Wait a couple of minutes and control that the outgoing air channel becomes warm.
If the outgoing air channel does not get warm, go back to step 4 and control that the electrical connection is installed correctly.
WARNING
It is always the buyer that has the responsibility to check that an authorized electrician makes the electrical connections of the cabinet.
WARNING
To prevent personal injuries, the cabinet shall always be connected permanently through an all pole main switch. Always ground the cabinet.
Also check that the connecting cable has a strain relief bushing. If not, there is a risk that the cabinet will be live.
©PODAB 2011 22
Turn the hanging frame
The hanging frame can be turned. Follow the steps below.
1. Loosen the upper Hex Key bolt, which holds the upper hanging level.
Support plate
2.
3.
Lift up the hanging frame and hook it off the tap below.
Put aside.
Loosen and push the panel on the top.
5.
6.
7.
8.
9.
10.
11.
12.
Unconnect the two cables which go from the keypad and
LCD to the main control board.
Lift up the plate and remove the cables. Connect the cables to the board again.
Before the support-plate is assembled on the other side of the cabinet; loosen the five torx screws on the left hand side.
Put the support-plate on the side to which the hanging frame will be moved.
Re-assemble the torx screws. Thereafter, fasten the bolts, upper stearing tap and the stop plate.
Put the front panel back on again.
Loosen and move also the lower tap to the opposite side.
To get the arms on the frame on the same level, each hanging level must be turned “upside down”. Loosen the upper hanging level from the frame.
4. Loosen the three bolts, the upper stearing tap and nut and the five torx screws which hold the plate and which support the stop plate. The drawings below shows where these parts are.
Stop plate
Stearing tap
23
©PODAB 2011
13. Rotate the hanging level 180 ° and fasten it again. Leave the upper bolt on the pole, unmounted.
14.
15.
16.
17.
Repeat the same moment with the three remaining hanging levels. Fasten both bolts.
Put the hanging frame back in and put the pole on the upper tap. Lower the pole so that it fits to the lower stearing tap.
Fasten the Hex Key bolt on the upper hanging level.
Control that the frame can be turned and that the stop function works properly also in the outer positions.
©PODAB 2011 24
Requirements for ventilation
WARNING
A drying cabinet produces inflammable dust. To minimize the risk for fire, the evacuation of the cabinet must be connected to a ventilation channel that evacuates the air.
Never let the evacuated air into a room or a surrounding where there is a risk for ignition.
Do not use ventilation channels in plastic or fire dangerous material.
Ventilation channel – choice of material
Ventilation channel, ducts, connections etc are not included.
The ventilation channels shall be at least 125 mm in diameter and should not have channels or similar on the inside.
We recommend that the ventilation system is built with rigid metal ducts for best result. Flexible evacuating ducts for drying cabinets can also be used.
NOTE: Never use flexible ducts through walls or other covered areas.
NOTE: Do not screw or nit the ventilation channel, so that the screws will come through the inside of the pipe. This construction will gather dust and impaire the cabinet’s performance.
The channel shall always be separated from the other ventiltion in the house.
Requirements for incoming air
In order to make the cabinet work properly, it is very important that there is enough incoming air in the room. If he cabinet is installed according to this manual the air flow from the exhaust will be about 230 m³/h. Incoming air must be at least equal to the outgoing flow. We recomend the incoming air flow to the room to be greater than the evacuated amount.
If the cabinet is placed in a room where the incoming air is not enough, we recommend that you install an air exchanger.
Ventilation channel – design
IMPORTANT: Always make the channels as short as possible.
NOTE: If a drying cabinet is installed in an old ventilation channel, please clean the channel properly.
In order to make the cabinet work properly, the incoming airflow must be enough. The amount of evacuated air per hour is depending on how high the pressure fall in the ventilation channel is.
25
Material, the design and the length of the channel have a large impact on the air flow. In order to get the best possible performance, the pressure fall shall be as low as possible.
When the air is transported through the channel, it is exposed to different kind of resistance. Factors that give a low pressure fall:
•
•
•
•
•
Smooth inner walls on the pipe
Large diameter on the pipe
Short length on the pipe
Few curves
Few angels (90 degrees)
©PODAB 2011
Evacuated amount of air and pressure fall
In order to get the cabinet to work properly, the ventilation channel shall be designed to get an out coming air flow from the cabinet of about 230 m³/h. When the cabinet is installed to an existing channel system, the cabinet can be calibrated to optimize the air flow.
In order to gain this air flow, the pressure fall must not exceed
70 Pa. By an airflow of 230 m³/h and a diameter of the pipe of 125 mm, this corresponds to a straight, smooth ventilation channel of 23 m.
Pressure fall estimation
The counter pressure in the ventilation channel can be measured with a pressure meter. The measuring point shall be placed by the cabinets evacuating outlet.
In order to estimate the pressure fall without meter equipment we recommend the following:
• Identify the ventilation channel’s incoming components in the
• air flow direction.
Check the part pressure fall for each component in the ta-
• ble.
Calculate the total amount of pressure fall by adding each parts pressure fall.
The table shows the most common components in a ventilation system. The information shall be considered as approximate data. For more information, contact the manufacturer of the parts of the system. Please note that the data in the table is for an air flow of 230 m³/h.
Decrease the outgoing air flow
The cabinets function and automatic programmes are optimized for the recommended air flow of 230 m³/h. If the design of the ventilation is made so that evacuated air flow exceeds 230 m³/h, the evacuation can be throttled with help of a damper.
Contact a ventilation expert in order to find a proper solution for your ventilation.
Component
Circular channel
Pipe bends 90 º r r
Ø
Ø
Ø
Ø
Ø
Ø r
Reduction
ø, mm
125
160
ø, mm
125
160 r, mm
125
160
Pressure fall
Pa/m
3,1
1,0
Pa/bend
6,5
2,5
Transition, mm
125 till 160
160 till 125
Pa/reduction
3,5
5,5
Example: 10 m long 125 mm channel with 3 pipe curves which gives an estimated pressure fall of (10 x 3,1) + (3 x 6,5) = 50,5 Pa.
NOTE: If the highest allowed level of air pressure is exceeded an external fan could be needed. Otherwise the drying result is effected negatively. TS 62 is prepared for an external fan. Contact your local dealer or PODAB for more information.
©PODAB 2011 26
User manual
Fill the cabinet
To get the best drying result: try to dry the same type of material with the same thickness at the same time. Distribute the clothing evenly in the cabinet. Never fill the cabinet with more than 8 kg laundry (dry weight). The most heat sensitive garment decides how high temperature that can be chosen.
Close the doors
The drying cabinet won’t start until the doors are completely closed.
Keypad
1 2
There are three levels:
Minimum (MIN) = 40ºC
Medium (MED) = 60ºC
Maximum (MAX) = 80ºC
The degrees stated above, show the maximum temperature of the warm air stream.
Set time
Increase or reduce the drying time with the arrow buttons 6 and
7. The drying time can be increased to maximum 3 h. Lower temperature requires longer drying time.
Start
Push button 5 to start the cabinet.
8
3 4 5 6 7
1.
2.
3.
4.
5.
6.
7.
8.
Manual programme mode
Automatic programme mode*
Reduce the temperature
Increase the temperature
Start/stop the programme
Reduce the time
Increase the time*
LCD-display
*Will also change programme when you’re in the automatic programme mode.
Pause programme
To pause a working programme, open the doors. The drying time is paused. Close the doors and push start button to continue drying. If the doors are left open longer than 10 minutes, the programme is interrupted.
Change temperature or time during drying
Temperature and time can be adjusted during the drying process and the programme is in the heating phase. When the cabinet switches to cool down, neither time nor temperature can be changed.
Interrupt a programme
To interrupt a working programme, push the START/STOP button.
Manual programme mode
In order to set the time and temperature, push key no 1. LCD shows the settings for manual programmes. The cabinet is preset on average temperature 60ºC and 45 minutes drying time.
Automatic programme mode
The drying cabinet is equipped with the function HTS –
Humidity Tracking System. This function is activated in the automatic programme mode. The drying time adjusts to the laundry in the cabinet and is controlled by a humidity sensor.
To choose automatic programme mode
Choose automatic programme mode by pushing button 2.
Set the temperature
Increase or reduce the temperature with the arrow buttons 3 and 4.
27
The cabinet has two automatic programmes; wardrobe dry and iron dry. By choosing either of those programmes, the drying time is adjusted automatically.
©PODAB 2011
Programme wardrobe dry
When automatic mode is activated, the programme “wardrobe dry” is set as first choice. Wardrobe dry means that the clothes are completely dry when the programme is finished.
Programme iron dry
To change automatic programme, push button no 2 once more.
Programme “iron dry” dries the clothes until about 15% residual moisture is left in the textiles. Use this programme when you have clothes that shall be ironed or mangled directly after the drying.
Automatic programmes; temperature
Automatic programme uses the maximum temperature of 80ºC.
Use manual programme mode for clothes that shall be dried in lower temperatures.
Start programme
Push button 5 to start the cabinet.
Pause programme
To pause a working programme, open the doors. The drying time is paused. The cabinet will start again when the doors are closed and the start button is pushed. If the doors are left open longer than 10 minutes, the programme is interrupted.
Interrupt a programme
To interrupt a working programme, push the START/STOP button.
Cool down
All programmes, both manual and automatic ones, have a cool down phase of 15 minutes. This time is in the chosen time when you chose the manual programmes. During cool down the clothes are reconditioned and the drying cabinet is cooled downed.
CAUTION
If a program is interrupted before the cool down has finished, the ceiling of the cabinet could be very hot.
©PODAB 2011 28
Maintenance
Take good care of the cabinet
Only use a damp cloth with a mild detergent when cleaning the cabinet. Never use solvent to clean the display.
Ventilation system
Loosen the ventilation pipe on the cabinet every year and clean if necessary around the evacuating channel.
IMPORTANT: Always switch off the electricity before starting to work with the cabinet.
Inspect with set intervals the complete ventilation channel; don’t forget the outer wall. There can easily be leafs and other rubbish that chokes.
We recommend that you once a year, take down the service doors and vacuum clean around the fans and elements.
Keep your cabinet efficient and economical
• The ventilation channels shall be as short as possible.
• If possible, dry the same type of textiles at the same time.
• Do not dry with maximum temperature if you do not need to.
29
©PODAB 2011
Notes
©PODAB 2011 30
31
©PODAB 2011
SERVICE/SUPPORT
Phone +46 31-752 01 00
Fax +46 31-752 01 50
E-mail [email protected] www.podab.com
AB PODAB, Ekonomivägen 9, 436 33 Askim, SWEDEN
Tel +46 (0)31-752 01 00, Fax +46 (0) 31-752 01 50 E-mail: [email protected], www.podab.com
©PODAB 2011-01-21