Halton Max Ultra Circular (MUC) - Installation, commissioning and maintenance guide Enabling Wellbeing All rights reserved © Halton Halton Max Ultra Circular (MUC) - Installation, commissioning and maintenance guide 2(31) Contents 1 Introduction ......................................................................................................................................... 3 1.1 About this document .................................................................................................................... 3 1.2 Copyright and disclaimers ............................................................................................................. 3 1.3 Safety notes .................................................................................................................................. 3 1.4 Contact information ...................................................................................................................... 5 2 Product description .............................................................................................................................. 6 2.1 Overview ....................................................................................................................................... 6 2.2 Operating principle ....................................................................................................................... 7 2.3 Structure and materials ................................................................................................................ 8 3 Installation ........................................................................................................................................... 9 3.1 Before you start ............................................................................................................................ 9 3.1.1 Installation process ................................................................................................................ 9 3.1.2 Installation information ......................................................................................................... 9 3.2 Step by step instructions ............................................................................................................. 14 3.2.1 Connecting the damper to the ductwork ............................................................................ 14 3.2.2 Connecting the wiring .......................................................................................................... 17 4 Commissioning ................................................................................................................................... 18 4.1 Before you start .......................................................................................................................... 18 4.1.1 Commissioning process........................................................................................................ 18 4.1.2 Airflow controller display ..................................................................................................... 18 4.1.3 Modbus RTU communication .............................................................................................. 19 4.1.4 Factory settings .................................................................................................................... 19 4.2 Start up ........................................................................................................................................ 20 4.3 Basic controller settings .............................................................................................................. 21 4.4 Resetting the parameters ........................................................................................................... 23 5 Maintenance ...................................................................................................................................... 24 6 Technical reference data.................................................................................................................... 25 6.1 Dimensions and weight ............................................................................................................... 25 6.2 Installation parameters ............................................................................................................... 26 6.3 Modbus RTU variables ................................................................................................................ 29 Version 1.0 All rights reserved © Halton Halton Max Ultra Circular (MUC) - Installation, commissioning and maintenance guide 3(31) 1 Introduction 1.1 About this document This guide provides guidelines for installing, commissioning and maintenance of the Halton ultrasound damper. 1.2 Copyright and disclaimers The contents of this document are strictly confidential and for information purposes only. Disclosing the information in this document without an appropriate contract or permission by Halton to any third party is prohibited. This document remains the sole property of Halton and may not be duplicated, borrowed, copied, amended, modified, reproduced, transmitted or distributed to any third party without the prior written consent of Halton. Any information held in this document or associated materials may only be used for the purpose specified in this document. Halton disclaims any and all liability related to this document. Halton gives no explicit or implied warranties in terms of this document. Any permitted use of the information included herein is at your own risk. Halton may amend or replace the information included in this document at its sole discretion without further notice and liability. All intellectual property rights or applications thereof, including without limitation copyright, model rights, patents, trade secrets, trade names, trademarks, know-how (whether registered or unregistered) attributable to this document remain the sole and exclusive property of Halton. No rights or licenses are granted. 1.3 Safety notes All information in this section is important and relevant for your safety. Please pay special attention to these icons and the accompanying messages when used later in context in this manual. Warnings Warning signs indicate a risk of personal injury including death. There is also a potential risk of material damage. Pay attention to the following signs when performing any tasks or moving in the area: WARNING! This symbol indicates a potential hazard, obstacle or condition requiring special attention. Version 1.0 All rights reserved © Halton Halton Max Ultra Circular (MUC) - Installation, commissioning and maintenance guide 4(31) DANGER OF ROTATING UNIT PARTS! This symbol indicates a hazardous location with a risk of personal injury including death and material damage. DANGER OF OVERHEAD LOADS! This symbol indicates a hazardous location with a risk of personal injury including death and material damage. DANGER OF PERSONAL INJURY! This symbol indicates a hazardous location (excluding the above-mentioned danger areas) with a risk of personal injury including death and material damage. Cautions Caution signs indicate a risk of personal injury or material damage. To ensure your own safety, consider the following cautions: CAUTION! This symbol indicates a hazardous location with a risk of material damage that can also lead to personal injury. CAUTION! HEAVY OBJECT Do not lift objects over 20kg (44lbs) alone. Use a lift or seek assistance. Version 1.0 All rights reserved © Halton Halton Max Ultra Circular (MUC) - Installation, commissioning and maintenance guide 5(31) CAUTION! Risk of personal injury or material damage. Notes NOTE: Notes are statements to which you should pay special attention. 1.4 Contact information You can find the contact details from www.halton.com/contact. Version 1.0 All rights reserved © Halton Halton Max Ultra Circular (MUC) - Installation, commissioning and maintenance guide 6(31) 2 Product description 2.1 Overview Halton Max Ultra Circular (MUC) Circular airflow management damper using the ultrasound technique for airflow measurement. Application areas • Standard VAV and CAV applications • Supply and exhaust installations Key features • Insensitive to dust collection • Enables flexibility in terms of space layout • Individually calibrated for higher accuracies • Low pressure loss for reducing the noise level • Can be connected to Buildings Management System (BMS) Version 1.0 All rights reserved © Halton Halton Max Ultra Circular (MUC) - Installation, commissioning and maintenance guide 7(31) 2.2 Operating principle Fig.1. Halton Max Ultra Circular (MUC) has two ultrasound sensors for airflow measurement. The damper can function either as a supply or an exhaust unit. It maintains the required airflow through ultrasound measurement, regardless of variations in the room conditions or duct pressure. The damper has an airflow controller, two ultrasound sensors for airflow measurement, and an actuator for controlling the damper blade. The airflow controller can be controlled via: • Modbus RTU, • the control panel, • an analogue signal. All three control modes are synchronized between each other. The airflow measurement includes temperature and duct type connection compensations, providing accurate and reliable airflow measurements even at small safety distances. Room conditions can be adjusted • manually from an end-user interface Version 1.0 All rights reserved © Halton Halton Max Ultra Circular (MUC) - Installation, commissioning and maintenance guide 8(31) • by different sensors such as occupancy or room pressure sensors, thermostats or timers • remotely from a building management system (BMS) The airflow setpoint can be modified between the minimum and maximum settings from the room controller interface or a BMS. 2.3 Structure and materials No. Part 1 Casing 2 3 4 5 6 7 8 9 Material Galvanised steel or stainless steel (EN 1.4404, AISI 316L) Duct seal gasket Rubber Shaft Galvanised steel or stainless steel (EN 1.4404, AISI 316L) Blade Galvanised steel or stainless steel (EN 1.4404, AISI 316L) Blade gasket EPDM rubber Actuator Plastic, steel, PVC cable Ethernet cable (LSZH) Cable Ultrasound sensor and temperature sensor Plastic ABS Airflow controller Plastic ABS Version 1.0 All rights reserved © Halton Halton Max Ultra Circular (MUC) - Installation, commissioning and maintenance guide 9(31) 3 Installation 3.1 Before you start 3.1.1 Installation process The installation is carried out by Halton Field Service or an approved partner. Follow the installation process chart to install the Halton Max Ultra Circular (MUC) damper. Fig.2. Halton Max Ultra Circular (MUC) installation process chart 3.1.2 Installation information Installation options There are three possibilities to position the damper. Sensors can be directed outwards, side or inwards. Safety distances and accuracy Disturbances in the ductwork such as duct bends, T-branches and sound attenuators cause turbulence and an uneven airflow. This can lead to fluctuation and inaccuracy in measurement values. NOTE: The recommended safety distance is greater or equal to one duct diameter distance, to ensure the optimal accuracy. Halton Max Ultra Circular (MUC) technical performance: • Velocity range 0,5 — 10,0 m/s Version 1.0 All rights reserved © Halton Halton Max Ultra Circular (MUC) - Installation, commissioning and maintenance guide 10(31) • General Measurement Uncertainty Accuracy ±5 % Minimum Safety distance 1D • Expected Measurement Uncertainty, when correct installation parameter is applied ± % or l/s depending, which is the greatest of the percentage or the absolute value for the specific product size. Dim. 100 = ±5 % or ±1,00 l/s Dim. 125 = ±5 % or ±1,25 l/s Dim. 160 = ±5 % or ±2,5 l/s Dim. 200 = ±5 % or ±4,0 l/s Dim. 250 = ±5 % or ±6,5 l/s Dim. 315 = ±10 % or ±10 l/s NOTE : The measurement uncertainty is defined in laboratory conditions and may be greater in practical installations, where non-optimal installation situations or multiple consequent disturbances may exist. Fig.3. Minimum safety distances If the straight duct between the damper and disturbance is less than five times the duct diameter distance, then the installation factor needs to be added to the airflow controller during commissioning. NOTE: The installation factors can be found in the 6.2.Installation parameters chapter. Wiring and controller connections The wiring must be carried out by professional technicians following local regulations. For the power supply, a safety-isolating transformer must be used. Version 1.0 All rights reserved © Halton Halton Max Ultra Circular (MUC) - Installation, commissioning and maintenance guide 11(31) Controller connections Terminal 1 2 3 4 5 6 7** 8 9 10 11 12* 13* 14* 15* Name GND 24 V DC/AC GND Standard RS-485 B Standard RS-485 A GND AI3 GND AI1 GND AO1 AI2 AO2 GND 24 V DC/AC Comment Ground Power supply input Ground Data receive/send line B Data receive/send line A Ground Input for NTC 10k temperature sensor (optional) Ground Input for airflow or damper reference signal Ground Output for airflow or damper feedback signal Analogue actuator feedback signal Analogue actuator reference signal Ground Power supply output for the analogue actuator * Connected to Siemens GDB 161.1E actuator. ** Not included in delivery Version 1.0 All rights reserved © Halton Halton Max Ultra Circular (MUC) - Installation, commissioning and maintenance guide 12(31) Wiring Fig.4. Wiring example for Halton Max Ultra Circular (MUC) with a parallel configuration Fig.5. Wiring diagram for parallel configuration (Modbus optional) Version 1.0 All rights reserved © Halton Halton Max Ultra Circular (MUC) - Installation, commissioning and maintenance guide 13(31) Fig.6. Wiring example for Halton Max Ultra Circular (MUC) with a master-slave configuration In the following example, the supply unit is controlling the exhaust unit. Fig.7. Wiring diagram for master-slave configuration (Modbus optional) Version 1.0 All rights reserved © Halton Halton Max Ultra Circular (MUC) - Installation, commissioning and maintenance guide 14(31) 3.2 Step by step instructions 3.2.1 Connecting the damper to the ductwork Before you start • Check the inside of the damper for damage and loose parts. • Remove any contamination from the ductwork. • Support the installation with a suitable suspension system. Load suspension systems only with the weight of the unit. Adjacent components and connecting ducts must be supported separately. • Wear protective gloves. CAUTION! Risk of personal injury or material damage. Procedure Position the damper so that the display is visible. NOTE: See safety distance in installation information chapter. There are three possible positions of the damper: o Version 1.0 Outwards o All rights reserved © Halton Side Halton Max Ultra Circular (MUC) - Installation, commissioning and maintenance guide 15(31) o Inwards 1. Push ducts onto the damper. The damper is fitted with seal gaskets. 2. Drill the holes for pop rivets. Version 1.0 All rights reserved © Halton Halton Max Ultra Circular (MUC) - Installation, commissioning and maintenance guide 16(31) 3. Fix the duct to the damper with pop rivets such that it cannot be moved. NOTE: The fixing material is not included in the delivery. Results The damper is installed. What to do next Use tape to ensure tightness, if necessary. Version 1.0 All rights reserved © Halton Halton Max Ultra Circular (MUC) - Installation, commissioning and maintenance guide 17(31) 3.2.2 Connecting the wiring ELECTRICAL HAZARD! Before carrying out any work, turn off the power supply to avoid injury from electrical current. Procedure 1. Unscrew the controller cover. 2. Connect input, output and communication wires. NOTE: See Installation information in installation information chapter. 3. Put controller cover back to place and fasten the screws. 4. Switch on the power supply. Version 1.0 All rights reserved © Halton Halton Max Ultra Circular (MUC) - Installation, commissioning and maintenance guide 18(31) 4 Commissioning 4.1 Before you start 4.1.1 Commissioning process The main steps in the commissioning process are: • Controller settings • Setting the installation parameter • Setting the Modbus communication parameters (optional) 4.1.2 Airflow controller display Halton Max Ultra Circular (MUC) airflow control has a control panel with display and four push buttons. Fig.8. Control panel The LCD display can show 16 characters in 2 lines. You can toggle between different parameter settings by pressing the arrow buttons. When the 'Setting' parameter is on view you can go back to parameter pages by pressing the OK button. If no button is pressed, the display goes back into default view. LED lights indicate Modbus communication. The red light indicates RS-485 Rx communication packet from master. The green light indicates RS-485 Tx communication packet to master. Version 1.0 All rights reserved © Halton Halton Max Ultra Circular (MUC) - Installation, commissioning and maintenance guide 19(31) 4.1.3 Modbus RTU communication Halton Max One Circular (MUC) can communicate to BMS system via Modbus RTU. Whit Modbus register user can read and set parameter values. Modbus parameter list can find end of document. To set parameters via Modbus, user need send password to MUC before it approve changes. When set Holding register or Coils, first send register value what like to change and after that send 9055 value to Holding register 40905. 4.1.4 Factory settings The airflow rates for Halton Max Ultra Circular (MUC) are preset at the factory. If the airflow rates are not specified by the customer, the default factory settings are 0 for the minimum airflow rate and the 10 m/s flow velocity for the maximum rate. The maximum airflow rates in the following table are given with a flow velocity of 10 m/s. Applies to all Halton Max Ultra Circular (MUC) actuator models. NS 100 125 160 200 250 315 Maximum airflow (l/s) @ 10 m/s 78 122 201 314 490 779 Maximum airflow (m3/h) @ 10 m/s 283 441 723 1130 1767 2805 Table 1. Halton Max Ultra Circular (MUC) factory settings Version 1.0 All rights reserved © Halton Halton Max Ultra Circular (MUC) - Installation, commissioning and maintenance guide 20(31) 4.2 Start up Press the OK button to move to the next step. Press the ESC button to move to the previous step. Procedure 1. When the controller is powered, the software version number is displayed. 2. The measured airflow is displayed in m/s. 3. The measured airflow is displayed in m3/h. 4. The measured airflow is displayed in l/s. 5. The damper blade position is indicated in percentage (0-100%). 6. The temperature measurement is displayed. 7. The room temperature measurement is displayed. Version 1.0 All rights reserved © Halton 4.3 Basic controller settings Press the OK button to move to the next step. Press the ESC button to move to the previous step. Change the parameters settings with left and right push buttons. 1. Set the parameter CtrlMode to Console / Modbus / Analog. 2. Set the parameter CtrlSig to AF / Damper 3. Set the parameter DtID to #0 - #51. NOTE: The installation factor (DtID) parameter values can be found in the Installation parameters chapter. 4. Set the parameter SP to Airflow or Damper position. NOTE: If the parameter CtrlMode is set to the other value than Console, go back to step 1 and set CtrlMode to Console. 5. Set the parameter AirFlowDB to Deadband. NOTE: If the parameter CtrlMode is set to Modbus, go back to step 1 and set CtrlMode to Console or Analog. 6. Set the Modbus RTU parameters. a. Set SlvID parameter to the value 1...246. b. Set the Baud parameter to the value 4k8 / 9k6 / 14k4 / 19k2 / 38k4 / 56k0 / 57k6 / 115k2. c. Set the Pr parameter to the value None / Even / Odd. 7. Set input for airflow or damper reference signal parameters. a. Set the AI1type parameter to the value Voltage / Current. b. Set the AI1rg parameter to 0..10V / 2..10V if AI1type value is Voltage or 0..20mA/4..20mA if AI1type is Current. c. Set the AI1min parameter to the value 0..15m/s*CrossSection*3600. d. Set the AI1max parameter to the value 1..15m/s*CrossSection*3600. 8. Set AO1 parameters. a. Set the AO1sig parameter to the value AirFlow / Damper. b. Set the AO1actSP parameter to the value Actual / SP. Enabling Wellbeing All rights reserved © Halton Halton Max Ultra Circular (MUC) - Installation, commissioning and maintenance guide 22(31) c. Set the AO1type parameter to the value Voltage / Current. d. Set the AO1rg parameter to the value 0...10V / 2... 10 V if AI1type is Voltage or to 0...20mA / 4...20mA if AI1type is Current. e. Set the AO1min parameter to the value 0...15 m/s *CrossSection* 3600. NOTE: The AO1min parameter is used only if Ctrlsig parameter has value AF. f. Set the AO1max parameter to the value 1...15 m/s *CrossSection* NOTE: The AO1max parameter is used only if Ctrlsig parameter has value AF. 9. Set the ActType parameters to the value Analog / LAC1.MA1 10. Set the analog actuator feedback signal parameters. a. Set the AI2type parameter to Voltage / Current, b. Set the AI2rg parameter to 0...10V / 2...10V if AI1type is Voltage or to 0...20mA / 4...20mA if AI1type is Current. 11. Set the analog actuator reference signal parameters. a. Set the AO2type parameter to the value Voltage / Current. b. Set the AO2rg parameter to the value 0...10V / 2...10V if AI1type is Voltage or to 0...20mA / 4...20mA if AI1type is Current. 12. Set the PI regulator parameters. a. Set the kp parameter to the value 0...100.0. b. Set the ki parameter to the value 0...100.0 Version 1.0 All rights reserved © Halton Halton Max Ultra Circular (MUC) - Installation, commissioning and maintenance guide 23(31) 4.4 Resetting the parameters These parameters are defined and set in the final testing in production. Changing of these parameters should only be done by qualified person. Enter the menu by pushing the following buttons combination: Left, Right, OK for 2s. 1. Set ZoffAct parameter to the value -150...150. 2. Initiate the calibration sequence start by pressing the OK button. 3. Check if the damper blade is in a closed position. 4. The calibration sequence is initiated. 5. Set the FinalK parameter to the value 0.500...1.500. 6. Set the actuator parameters. a. Set the ADB parameter to the value 0..2..00%. b. Set the Dir parameter to the value Fwd / Rev. c. Set the ReT parameter to the value 1...999. 7. Initiate a recalibration sequence by pressing the OK button. 8. Change Airoffset parameter with Left / Right. buttons. 9. Change AuxOffset parameter with Left / Right buttons. 10. The software version is displayed. 11. Controller working hours are displayed. 12. Actuator running hours are displayed. 13. Initiate resetting to factory settings by pressing the OK button. Version 1.0 All rights reserved © Halton Halton Max Ultra Circular (MUC) - Installation, commissioning and maintenance guide 24(31) 5 Maintenance ELECTRICAL HAZARD! Before carrying out any work, turn off the power supply to avoid injury from electrical current. Clean the ultrasound damper during the periodic cleaning of the ductwork. Set the damper blade in an open position. Don’t change the position of the sensors. Use soft, non-metal brushes. No other maintenance is needed. Version 1.0 All rights reserved © Halton Halton Max Ultra Circular (MUC) - Installation, commissioning and maintenance guide 25(31) 6 Technical reference data 6.1 Dimensions and weight NS 100 125 160 200 250 315 ⌀D 99 124 159 199 249 314 L 427 474 540 612 705 825 Version 1.0 L1 355 402 468 540 633 753 L2 15 38 70 H 127 153 187 227 277 342 H1 153 178 213 253 303 368 Weight (kg) 1.9 2.2 2.7 3.3 4.3 5.8 All rights reserved © Halton Halton Max Ultra Circular (MUC) - Installation, commissioning and maintenance guide 26(31) 6.2 Installation parameters Picture Sensor position - Safety distance (L) - - - Outwards Version 1.0 All rights reserved © Halton Installation parameter #0 1D #1 >1D #2 1D #3 2D #4 3D #5 >3D #6 1D #7 2D #8 3D #9 5D #10 >5D #11 Halton Max Ultra Circular (MUC) - Installation, commissioning and maintenance guide 27(31) Picture Sensor position Inwards Safety distance (L) 1D Side Outwards Inwards Version 1.0 All rights reserved © Halton Installation parameter #12 2D #13 3D #14 5D #15 >5D #16 1D #17 2D #18 3D #19 5D #20 >5D #21 1D #22 2D #23 3D #24 5D #25 >5D #26 1D #27 2D #28 3D #29 5D #30 >5D #31 Halton Max Ultra Circular (MUC) - Installation, commissioning and maintenance guide 28(31) Picture Sensor position Side Safety distance (L) 1D Outwards Inwards Side Version 1.0 All rights reserved © Halton Installation parameter #32 2D #33 3D #34 5D #35 >5D #36 1D #37 2D #38 3D #39 5D #40 >5D #41 1D #42 2D #43 3D #44 5D #45 >5D #46 1D #47 2D #48 3D #49 5D #50 >5D #51 Halton Max Ultra Circular (MUC) - Installation, commissioning and maintenance guide 29(31) 6.3 Modbus RTU variables 3xxxx, Input register Register Name 30001 FWver 30002 Description Firmware version 30006 Counter of controller working hours, high word CWorkingHoursLo Counter of controller working hours, low word AWorkingHoursHi Counter of actuator working hours, high word AWorkingHoursLo Counter of actuator working hours, low word AirSpeed Air speed 30007 AirFlow Airflow 30009 AirFlow Airflow 30011 AirTemp Temperature inside the duct 30012 AuxTemp Temperature of auxiliary sensor 30013 ControlMode Control mode feedback 30014 DamperPosition Damper position feedback 30015 DamperStatus Status of damper 30003 30004 30005 CWorkingHoursHi 4xxxx, Holding register Register Name Description 40001 ControlledSignal Selection between airflow regulation or damper manual position 40002 SelectDuctType Select installation factor 40003 AirFlowSP Setpoint for airflow regulation Version 1.0 All rights reserved © Halton Value 0 .. 65535 → 0 .. 65535 ver 0 .. 65535 → 0 .. 65535 h 0 .. 65535 → 0 .. 65535 h 0 .. 65535 → 0 .. 65535 h 0 .. 65535 → 0 .. 65535 h 20 .. 1500 → 0.20 .. 15.00 m/s 0 .. 65535 → 0 .. 65535 m3/h 0 .. 65535 → 0 .. 65535 l/s 500 .. 4000 → 5.00 .. 40.00°C 0 .. 5000 → 0.00 .. 50.00°C 0 → Modbus 1 → Console 2 → Analog 0 .. 10000 → 0.00 .. 100.00% 0 → Stop 1 → Closing 2 → Opening Value 0 → Air flow 1 → Damper position 0...51 0 .. 65535 → 0 .. 65535 m3/h Halton Max Ultra Circular (MUC) - Installation, commissioning and maintenance guide 30(31) 4xxxx, Holding register Register Name 40004 AirFlowDB 40005 DamperSP Description Airflow regulation deadband, percentage of AirFlowSP Setpoint for damper position 40023 AI1scaleMin Analog input 1 minimum value 40024 AI1scaleMax Analog input 1 maximum value 40025 AO1scaleMin Analog output 1 minimum value 40026 AO1scaleMax Analog output 1 maximum value 40030 Kp K factor of PI regulator 40031 Ki I factor of PI regulator 40905 SaveR Save and take over “R” parameters Version 1.0 All rights reserved © Halton Value 0 .. 10000 → 0.00 .. 100.00% 0 .. 10000 → 0.00 .. 100.00% 0 .. 65535 → 0 .. 65535 m3/h 0 .. 65535 → 0 .. 65535 m3/h 0 .. 65535 → 0 .. 65535 m3/h 0 .. 65535 → 0 .. 65535 m3/h 0 .. 1000 → 0.0 .. 100.0 0 .. 1000 → 0.0 .. 100.0 9055 Halton Max Ultra Circular (MUC) - Installation, commissioning and maintenance guide 31(31) 0xxxx, Coils Register Name 00001 AI1type Description Voltage or current type of AI1 00002 AI1rg Range of AI1 00003 AO1sig Signal on AO1 00004 AO1actSP Actual or set point value 00005 AO1type Voltage or current type of AO1 00006 AO1rg Range of AO1 00007 AI2type Voltage or current type of AI2 00008 AI2rg Range of AI2 00009 AO2type Voltage or current type of AO2 00010 AO2rg Range of AO2 00011 ActuatorType Type of actuator 1xxxx, Discreate inputs Register Name 10001 ErrCode1 10004 ErrCode4 10005 ErrCode5 10006 ErrCode6 Version 1.0 Description Wrong sensor connection or sensors not connected Air temperature sensor A is not working Air temperature sensor B is not working End switch position of LAC-1.MA1 is faulty All rights reserved © Halton Value '0' → Voltage '1' → Current '0' → 0-10V/0-20mA '1' → 2-10V/4-20mA '0' → Air flow '1' → Damper position '0' → Actual 1' → Set point 0' → Voltage '1' → Current '0' → 0-10V/0-20mA '1' → 2-10V/4-20mA '0' → Voltage 1' → Current '0' → 0-10V/0-20mA '1' → 2-10V/4-20mA '0' → Voltage '1' → Current '0' → 0-10V/0-20mA '1' → 2-10V/4-20mA '0' → Analog '1' → LAC-1.MA1 Value '0' → No error '1' → Error '0' → No error '1' → Error '0' → No error '1' → Error '0' → No error '1' → Error ">

Public link updated
The public link to your chat has been updated.
Advertisement