- No category
advertisement
▼
Scroll to page 2
of 64
User manual CTX 300 Analogic Gas Detector Part Number: NP300GB Revision: K.2 →06/2015 The Fixed Gas Detection Experts Copyright 2015 by Oldham S.A.S. Juli 2015 All rights reserved. No reproduction of all or part of this document, in any form, is permitted without the written consent of Oldham S.A.S. All information provided in this document is accurate to the best of our knowledge. As a result of continuous research and development, the specifications of this product may be changed without prior notice. Oldham S.A.S Rue Orfila Z.I. Est – CS 20417 F – 62027 ARRAS Cedex Tel : +33 (0)3 21 60 80 80 Fax: +33 (0)3 21 60 80 00 2 CTX 300 User manual Contents Chapter 1 | General Information ..............................................5 User Manual ............................................................................................... 5 Symbols used ............................................................................................. 5 Safety instructions ...................................................................................... 6 Important information ................................................................................. 6 Liability limits .............................................................................................. 7 Chapter 2 | Introduction ...........................................................9 General Information ................................................................................... 9 CTX300 CO2 versions .............................................................................. 10 Composition ............................................................................................. 11 Chapter 3 | Installation and connection ................................ 13 Installing the detectors ............................................................................. 13 Electrical connections .............................................................................. 15 Chapter 4 | Powering up and use .......................................... 21 Powering up ............................................................................................. 21 4-20 mA analog output ............................................................................. 22 Chapter 5 | Maintenance ........................................................ 23 Calibration ................................................................................................ 23 Replacing a sensor .................................................................................. 37 Disposal.................................................................................................... 37 Chapter 6 | Spare parts .......................................................... 39 CTX/COX 300 toxic or oxygen sensors ................................................... 39 CSC 300 semiconductor sensors............................................................. 42 CTX 300 – CO2 sensors ........................................................................... 43 Chapter 7 | Certification ......................................................... 45 Contents 3 Chapter 8 Technical specifications ....................................... 49 Chapter 9 | Annex ................................................................... 53 Indications for calibrating the CTX 300 SC .............................................. 53 CTX 300 overview .................................................................................... 54 4 CTX 300 User manual | Chapter 1 | General Information User Manual The instructions given in this manual must be read thoroughly before installation and start-up, particularly those concerning the points related to the safety of the end-user. This user manual must be made available to every person involved in the activation, use, maintenance, and repair of the unit. The information, technical data, and diagrams contained in this manual are based on the information that is available at a given time. In case of doubt, contact Oldham for additional information. The aim of this manual is to supply simple and accurate information to the user. Oldham cannot be held liable for any misinterpretations in the reading of this manual. In spite of our efforts to produce an error-free manual, it may nonetheless contain some unintentional technical inaccuracies. In the client’s interest, Oldham reserves the right to modify the technical characteristics of its equipment to increase their performance without prior notice. The present instructions and their content are the inalienable property of Oldham. Symbols used Icon Significance This symbol indicates useful additional information. This symbol indicates: This equipment must be connected to ground. This symbol indicates: Protective earth terminal. A cable of the adequate diameter must be connected to ground and to the terminal having this symbol. 1 – General information 5 This symbol indicates: You must refer to the instructions. This symbol indicates: Warning! In the present mode of use, failure to adhere to the instructions preceded by this symbol can result in a risk of electric shock and/or death. European Union (and EEA) only. This symbol indicates that this product must not be discarded with household waste, as per the EEA directive (2002/96/EC) and your own national regulations. This product must be disposed of at a collection point that is reserved for this purpose, for example, an official site for the collection of electrical and electronic equipment (EEE) in view of their recycling, or a point of exchange for authorized products that is accessible when you acquire a new product of the same type. Any deviation as regards these recommendations for the disposal of this type of waste can have negative effects on the environment and public health, as these electric and electronic products generally contain substances that can be dangerous. Your full cooperation in the proper disposal of this product promotes a better use of natural resources. Safety instructions Labels intended to remind you of the principal precautions of use have been placed on the unit in the form of pictograms. These labels are considered an integral part of the unit. If a label falls off or becomes illegible, please ensure it is replaced. The significance of the labels is detailed below. The installation and electrical connections must be carried out by qualified personnel according to the instructions of the manufacturer and the standards of the competent authorities. Failure to adhere to the instructions can have serious consequences on the safety of persons. Please be extremely rigorous as regards electricity and assembly (coupling, network connections). Important information The modification of the material and the use of parts of an unspecified origin shall entail the cancellation of any form of warranty. The use of the unit has been projected for the applications specified in the technical characteristics. Exceeding the indicated values cannot in any case be authorized. 6 CTX 300 User manual Liability limits Neither Oldham nor any other associated company under any circumstances can be held liable for any damage, including, without limitations, damages for loss or interruption of manufacture, loss of information, defect of the MX 43 control unit, injuries, loss of time, financial or material loss, or any direct or indirect consequence of loss occurring in the context of the use or impossibility of use of the product, even in the event that Oldham has been informed of such damage. 1 – General information 7 8 CTX 300 User manual Chapter 2 | Introduction General Information CTX300 gas detectors are designed to measure toxic gases or vapors and oxygen. With robust materials, a specifically-adapted design, appropriate accessories, stainless bolts and a polyamide case (IP54), CTX 300 detectors are designed to withstand the roughest conditions. Figure 1: overview of a CTX 300 with display (left) and without display (right). 2 – Introduction 9 CTX300 CO2 versions In the case of a CTX 300 for the CO2 detection, this manual can only be used for devices delivered before July 2015. P/N : 6514879 P/N : 6314124 P/N : 6514880 P/N : 6514881 P/N : 6514882 Figure 2: CTX 300 CO2 detector delivered before July 2015 10 CTX 300 User manual Figure 3: CTX 300 CO2 detector delivered since July 2015 Composition Sensor type CTX 300 Toxic Oxygen 1 Semiconductor CO2 - Combustible gas. - Solvents. - Some Freons. CO2. Gases detected Common toxic Oxygen. gases detected. Detection method Electrochemical Electrochemical Semiconductor sensors (1). sensor. sensor. Infrared absorption. Type of sensor pack Pre-calibrated removable sensor pack (2). Pre-calibrated removable sensor pack: 0-30% scale or 0-100% volume. Removable sensor pack, not precalibrated. Removable sensor pack Infrared column, not pre-calibrated. Options With display. With display. Certification None. None None None (1) Specific to each gas. (2) Choice between several scales. 1 CTX 300 CO2 detector delivered before July 2015 2 – Introduction 11 12 CTX 300 User manual Chapter 3 | Installation and connection Installing the detectors Layout While the measuring sensor is always located on the underside of the detector, several factors determine where the detector should be located: ■ If the gas being measured is lighter than the air, place the detector near the ceiling. ■ If the gas is heavier than the air (CO2 and Freons, for example) place the detector close to the floor. ■ Near offtake points. ■ Generally, in locations where gas may accumulate, taking into consideration both: - The effects of temperature; - The outside winds direction. Determining the best sensor location Factors to consider when determining the best placement for the detector are: ■ Potential sources for vapor and gas emissions. ■ Characteristics of gases and vapors (density). ■ Air circulation: - Inside: mechanical or natural ventilation. - Outside: wind direction and velocity. ■ Effects of temperature. ■ Local constraints (air flow, water splash, etc.). Detectors should always be located in an easily accessible location for maintenance purposes. Special accessories may be necessary to protect the equipment against any liquid projectiles, dust, direct sunlight or low temperatures in the area. 3 - Installation and connection 13 Mechanical installation Figure 4: overall dimensions of the CTX 300. Figure 5: drilling diagram for wall mounting (view of the side flatten onto the ceiling). 14 CTX 300 User manual Figure 6: ceiling mounting with a brace. The fixing drawing is identical to this of the wall mount. Ref. Qty Description Code Material 1 1 Brace 6132380 Stainless 2 4 Washer A25 ACCD 6905518 Stainless 3 4 Screw CHC LI2 6902218 Stainless Electrical connections Wiring specifications If needed, consult the grounding instructions for Oldham instruments and related connection materials in Annex 1. Connections for the various types of sensors Wire CTX 300 (TOX/OX) with display CTX 300 (TOX/OX) without display CTX 300 SC/CO2 without display Output signal 4-20 mA 4-20 mA 4-20 mA Active wires 3 2 3 Cable entry 1 x 6-11 mm 1 x 6-11 mm 1 x 6-11 mm 3 - Installation and connection 15 Connection of a 3-wire sensor to an Oldham control unit Wire Terminal number (+) V DC power supply: 3 (-) V DC power supply (masse 0 V): 2 Output signal: 1 Control unit +24 VDC Detector 0V Signal Figure 7: connection of a 3-wire sensor to an Oldham control unit. Connection of a 2-wire sensor to an Oldham control unit Wire Terminal number (+) V DC power supply: 3 Output signal: 1 Both wires are the 4-20 mA 2-wire loop. +24 VDC Control unit Detector Signal Figure 8: connection of a 2-wire sensor to an Oldham control unit. 16 CTX 300 User manual Connection of a 3-wire CTX300 sensor to a non-OLDHAM control unit with an internal power supply Other control unit +24 VDC 0V Detector Signal Figure 9: Connection of a 3-wire CTX300 sensor to a non-OLDHAM control unit. (R) (A) Maximal load = 200 Ω. Power supply 15 ≤ Vcc ≤ 32. 18 ≤ Vcc ≤ 30 for CO2 sensor. I max = 130 mA. Connection of a 2-wire 4-20mA sensor to a non-Oldham control unit and to an internal power supply Other control unit +24 VDC Detector Signal Figure 10: Connection of a 2-wire 4-20mA sensor to a non-Oldham control unit. (A) Power supply 15< VCC<32V. I max = 30 mA. 3 - Installation and connection 17 Operating mode CTX300 with display ■ Remove the 4 screws (ref. 1). ■ Remove the cover (ref. 2). Figure 11 ■ Completely remove the screw (ref. 4). ■ Unscrew the screw a few turns (ref. 3). Figure 12 ■ Turn the display circuit as shown (ref. 5). ■ Connect the cable (ref. 6) to the connector. Refer to paragraph Connections for the various types of sensors on page 15. ■ Return the display circuit to its original position and replace the cover. Figure 13 18 CTX 300 User manual CTX 300 without display ■ Unscrew the 4 screws (ref. 1). ■ Remove the cover (rep. 2). ■ Proceed to wire the sensor according to the terminal location. Figure 14 3 - Installation and connection 19 20 CTX 300 User manual Chapter 4 | Powering up and use Powering up ■ The sensor turns on when connected to a power supply. ■ If the sensor has a display, the green LED will be lit (ref. 2) and a value will appear on the display screen (ref. 1). Figure 15 In case of a problem, verify that the maintenance switch (ref. 1), located on the main circuit, is in the MES (measure) position. Figure 16: CTX 300 circuit board. Figure 17: CTX 300 SC main circuit board. 4 – Powering up and use 21 Figure 18: CTX 300 CO2 main circuit board. This card does is not equipped with a MES-CAL switch. 4-20 mA analog output For CTX 300 sensors, except for the CO2 sensor, the 4-20 mA output current is proportional to the gas level. Notes: ■ The CO2 sensor can be equipped with a linearization board. ■ MX 15 and MX 32 control units that integrate with the linearization of the CO2 sensor are available upon request. ■ The MX 62 integrates with the linearization of CO2 sensors. The various states of the 4-20 mA output are: ■ 1 mA to indicate a fault. ■ = 2 mA in Calibration position, except for the CO2 sensor that does not have a calibration function. ■ Between 4 and 20 mA for measurement values. ■ ≥ 20 mA if levels exceed measurement range. 22 CTX 300 User manual Chapter 5 | Maintenance The adjustment operations in this paragraph are reserved for authorized, trained personnel because they may compromise detection reliability . Gas detectors are safety devices. OLDHAM recommends the regular testing of fixed gas detection installations. This type of test consists of injecting the calibration gas into the detector at a sufficient concentration to activate the pre-set alarms. It is to be understood that this test is in no way a replacement for a detector calibration. The frequency of gas tests depends on the industrial application where the detector is in use. Frequent inspections should be made in the months following the commissioning of the installation, and should then become more widely spaced provided that no significant deviation is observed. If a detector should fail to react in contact with the gas, calibration is essential. The frequency of calibrations shall be appropriate according to the results of the tests (humidity, temperature, dust, etc.); however, it must not exceed one year. The general manager should put safety procedures in place on-site. OLDHAM cannot be held responsible for their enforcement. Calibration Recommendations Calibration consists of adjusting the zero of the clean air sensor and adjusting sensitivity with a test gas. Adjustments are made at the sensor level. Equipment needed to calibrate the detector correctly: ■ Flexible plastic tubing (Figure 19, ref. 2). ■ Manometer and regulator valve for the compressed gas cylinders (rep. 3). ■ 0 to 60 l/h flow meter (if the cylinder is not equipped with one). ■ Calibration pipe (ref. 1), which may vary depending on the nature of the gas (see pages 39 and following). ■ Test gas cylinder (ref. 4). 5 – Maintenance 23 Figure 19: sensor calibration assembly. Zero adjustment should be performed in a gas and vapor free area. If this is not possible, synthetic bottled air can be injected at a rate of 60 l/h. Use a bottle of test gas to adjust sensor sensitivity (concentration close to the alarm threshold or corresponding to 30% of the measurement range at a minimum). The recommended rate is 60 l/h. Note: when dealing with dangerous gases, you MUST consult a specialized Oldham technician or use another sensor pack recently pre-calibrated at a factory. The detector should be calibrated using the intended flow-rate. The actual concentration of gas may be underestimated if the detector was calibrated with too high of a flow rate. CTX 300 calibration st 1 case: CTX 300 with display (excluding O2) ■ The sensor is operating: the green light (ref. 1) is lit and the display screen shows the measurement level. Figure 20 24 CTX 300 User manual ■ Flip the maintenance switch (ref. 1) into the CAL (calibration) position: the yellow light (Figure 20, ref. 2) will be lit and the sensor will send a 2 mA current to the control unit (Maintenance mode). ■ Verify that the sensor is located in a clean-air environment. If not, inject synthetic air at a flow rate of 30 l/h. Figure 21 ■ Wait for the measurement to stabilize (displayed on screen) and adjust the zero by using the ZERO potentiometer located on the sensor pack (ref. 2). ■ Inject the recommended calibration gas at a flow rate of 30 l/h. ■ Wait for the measurement to stabilize. ■ Adjust the sensitivity by using the sensitivity potentiometer located on the sensor pack (rep. 1). ■ Stop injecting the calibration gas. ■ Remove the gas injection pipe, then wait and verify that the signal returns to zero. Repeat procedure if it does not. ■ Flip the maintenance switch (rep. 1) into the MES (measure) position. The yellow light will turn off (Figure 20, rep. 2). ■ Calibration is complete. Figure 22 Figure 23 5 – Maintenance 25 2 nd case: CTX 300 without display (except for O2, SC and C02) ■ The sensor is operating. ■ Flip the maintenance switch (ref. 1) into the CAL (calibration) position: the sensor will send a 2 mA current to the control unit (Maintenance mode). ■ Verify that the sensor is located in a clean-air environment. Use the calibration kit and follow all recommendations. Figure 24 ■ Connect a voltmeter to the AF+ and AF- terminals (caliber mV/DC). Figure 25 ■ Wait for the signal to stabilize and adjust the zero by using the ZERO potentiometer located on the sensor pack (Figure 26, ref. 2). The output signal should be 0 mV. ■ Now inject the recommended test gas at a flow rate of 30 l/h. Use the calibration kit and follow all recommendations. ■ Wait until the signal has stabilized. ■ Read the mV value on the voltmeter (Figure 25), with the full scale at 1600 mV. Calculate the value to be read as a function of your test gas. 26 CTX 300 User manual Figure 26 ■ Adjust the displayed value using the potentiometer (Figure 26, rep.1). Example - CO sensor. - Scale 0-300 ppm. - Standard gas concentration: 100 ppm. - Reading: 533 mV. ■ Shut off the calibration gas injection. ■ Withdraw the gas injection pipe. ■ Then wait and check that the scale has returned to zero. Otherwise, repeat the entire procedure. ■ Switch the maintenance on/off switch to the MES (measure) position (ref. 1). Figure 27 5 – Maintenance 27 CTX 300 calibration for O2 This sensor is an Oxygen type. st 1 case: CTX 300 O2 with display st ■ See paragraph 1 case: CTX 300 with display, on page 24. Proceed only with adjusting sensitivity (rep. 1) by injection of test gas. Figure 28 2 nd ■ case: CTX 300 O2 without display screen nor LED nd See paragraph 2 case: CTX 300 without display on page 26. Proceed only with adjusting sensitivity (rep. 1) by injection of test gas. Signal value mV: - 1600 mV for full scale, means 30 % O2. - 1115 mV for 20.9 % O2. - 0 mV for 0% O2. Figure 29 Note: the signal sent from the CTX300 (toxic or oxygen) sensor to the control unit can be measured on the main circuit by connecting a millivoltmeter to the pins designed for this purpose (Figure 30). - 400 mV corresponds to 4 mA. - 2000 mV corresponds to 20 mA. Figure 30 28 CTX 300 User manual CTX 300 calibration (for Semiconductor) This is a Semiconductor type sensor. ■ Flip the switch (rep. 1) into the CAL position. Figure 31 ■ Ensure that the sensor is in clean air, otherwise inject synthetic air into it using the calibration kit and referring to the recommendations below. Important: to correctly calibrate a sensor equipped with a semiconductor cell, use of a humidifier kit (code 6335919) is MANDATORY. Using the humidifier kit - - - - Lift the lid (ref. A) and, using a washbottle, moisten the filter, without saturating it, with distilled water Replace the lid and check that all parts are properly assembled and that the assembly is fully airtight. Adjust the flow rate to 60 l/h and wait 10 minutes until the humidifier is fully purged. Apply the gas introduction pipe (ref. C) to the nose of the sensor and wait at least five minutes for the measurement to stabilize. Note: the sensor must be powered for at least two hours before any adjustment can be made. To detector (C) Gas input pipe (B) Filter (A) Lid (D) « Cristal » tubes. Length: 0.5 m To standard gas cylinder (gas input) Figure 32: the humidifier kit. 5 – Maintenance 29 ■ Connect a voltmeter as indicated and adjust, using potentiometer p5 (ref. 1). The output signal must be equal to 880 mV. ■ Next, inject the calibration gas at a flow rate of 30 l/h (refer to paragraph Indications for calibrating the CTX 300 SC, on page 53). ■ Wait for the signal to stabilize and adjust the signal with the sensitivity potentiometer p6 (ref. 2). The output signal should be: Figure 33 U = 880 mV + 3520 mV x Cal gas concentration Sensor measurement range Example Sensor measure (% of full range) Output signal (mV) 0 880 50 2 640 100 4 400 ■ Stop injecting the calibration gas. ■ Verify that the reading returns to zero (880 mV). If it does not, repeat the entire procedure. ■ Calibration is complete. ■ Flip the switch (ref. 1) into the MES (Measure) position. Figure 34 30 CTX 300 User manual CTX 300 CO2 calibration 1 This is a Carbone dioxide type sensor. ■ ■ Warning: the sensor should be turned on for 15 minutes before adjustments are made. The following text describes the steps necessary to adjust the transmitter (first calibration). Adjustment: if the current loop of the output signal has an impedance of 500 ohms, the power supply should never fall below 23 V DC. ■ Inject nitrogen at a rate of 30 l/h. ■ On the X1 terminal board, place an ammeter between terminals 1 (+) and 2 (-). ■ With the potentiometer Z, adjust the current to 4 mA. ■ With the ammeter still connected, inject the test gas at a rate of 60 l/h. ■ Adjust the sensitivity with the potentiometer S. Refer to the paragraph Calibration curves, on page 32 for sensors without linearization cards. ■ If this fails, flip the J2 jumper and begin again. Figure 35 1 CTX 300 CO2 detector delivered before July 2015 5 – Maintenance 31 CTX 300 CO2 linearization card ■ If you use a linearization card, the connection is the following. Terminal A Central terminal number 2 (GND) 1 3 (+24V) 3 1 (I out) 2 Terminal B Central terminal number In Iout GND GND +24V +24V Figure 36 Calibration curves The following pages present the calibration curves, that means the output signal of different CO2-IR transmitters. ■ CO2 sensor, 0-1 % scale. ■ CO2 sensor, 0-5 % scale. ■ CO2 sensor, 0-10 % scale. ■ CO2 sensor, 0-50 % scale. 32 CTX 300 User manual ppm CO2 Display % range Current mA ppm CO2 Display % range Current mA 0 0 4 5500 76 16.16 500 14 6.24 6000 79 16.64 1000 27 8.32 6500 82 17.12 1500 35 9.6 7000 85 17.6 2000 43 10.88 7500 88 18.08 2500 49 11.84 8000 90 18.4 3000 55 12.8 8500 93 18.88 3500 60 13.6 9000 96 19.36 4000 64 14.24 9500 98 19.68 4500 68 14.88 10000 100 20 5000 71 15.36 Figure 37: signal CO2-IR transmitter output signal – 0-1 % scale. 5 – Maintenance 33 % CO2 Display % range Current mA 0,00 0 4,0 0,25 21.6 7.46 0,50 33.1 9.3 1,00 48.4 11.74 1,50 60.1 13.62 2,00 68.6 14.98 2,50 75.6 16.1 3,00 82.4 17.18 3,50 86.7 17.87 4,00 91.7 18.67 4,50 95.8 19.33 5,00 100 20 Figure 38: signal CO2-IR transmitter output signal – 0-5 % scale. 34 CTX 300 User manual 20 18 Current mA 16 14 12 10 8 6 4 2 0 0 % CO2 1 2 Display % range 3 4 5 6 7 Concentration % CO2 8 9 10 Current mA 0,00 0 4,0 1,00 41.25 10,6 2,00 56.875 13,1 3,00 67.5 14,8 4,00 75.625 16,1 5,00 80.625 16,9 6,00 86.875 17,9 7,00 91.25 18,6 8,00 95.625 19,3 9,00 98.75 19,8 10,00 100 20,0 Figure 39 : signal CO2-IR transmitter output signal – 0-10 % scale. 5 – Maintenance 35 % CO2 Display % range Current mA % CO2 Display % range Current mA 0 0 4,0 20 74.2 15.87 1 13.4 6.14 25 80.4 16.86 2 21.6 7.46 30 85.6 17.7 3 28.4 8.54 35 90.7 18.51 5 38.1 10.1 40 93.8 19.01 10 54.6 12.74 45 96.9 19.5 15 66 14.87 50 100 20 Figure 40 : signal CO2-IR transmitter output signal – 0-50 % scale. 36 CTX 300 User manual Replacing a sensor Sensors must be replaced: ■ When calibration is no longer possible (no sensitivity); ■ During preventative maintenance. The replacement sensor should be identical to the original sensor (same gas, same range). After a sensor has been replaced, a calibration or test (for pre-calibrated sensors) must be conducted. Disposal For the preservation, protection and improvement of environmental quality, and for the protection of human health and the prudent and rational utilization of natural resources, the CTX 300 must be disposed of separately from electronic equipment and cannot be disposed of with normal household waste. The user therefore has an obligation to separate the CTX 300 sensor from other waste to ensure that it is recycled safely for the environment. For further details on existing collection sites, contact the local administration or seller of the product. 5 – Maintenance 37 38 CTX 300 User manual Chapter 6 | Spare parts List of spare parts for different detectors. Replacement parts must imperatively be guaranteed origin Oldham. Otherwise, material safety could be jeopardized. CTX/COX 300 toxic or oxygen sensors P/N Description 6147868 CTX 300 tool kit. 6322420 Mounting brace and bolts (CTX 300) ceiling mount. 6323607 Gas collector (s). 6331137 Gas introduction device for O2, C0, H2S, NO, H2. 6331141 Gas introduction device for explosible gases and other toxic gases. Picture 6 – Spare parts 39 P/N Description 6327906 Device for remote gas introduction. 6335953 Replacement filter. PTFE protector filter. Pre-calibrated oxygen sensor pack 6313C2A CTX 300 O2, 0-30 % vol sensor pack. (2years) 6313C5A CTX 300 O2, 0-30 % vol sensor pack. (5years) 6313660 CTX 300 O2, 0-100 % vol sensor pack. Pre-calibrated toxic sensor pack 6313627 CTX 300 CO - 100 ppm sensor pack. 6313628 CTX 300 CO - 300 ppm sensor pack. 6313629 CTX 300 CO - 1000 ppm sensor pack. 6313631 CTX 300 CO - 1% vol sensor pack. 6313632 CTX 300 CO - 10% vol sensor pack. 6313633 CTX 300 H2S - 30 ppm sensor pack. 6313634 CTX 300 H2S - 100 ppm sensor pack. 6313635 CTX 300 H2S - 1000 ppm sensor pack. 6313636 CTX 300 NO - 100 ppm sensor pack. 6313637 CTX 300 NO - 300 ppm sensor pack. 6313638 CTX 300 NO - 1000 ppm sensor pack. 6313639 CTX 300 NO2 - 10 ppm sensor pack. 6313640 CTX 300 NO2 - 30 ppm sensor pack. 6314001 CTX 300 NO2 - 100 ppm sensor pack. 6313645 CTX 300 ETO - 30 ppm sensor pack. 6313646 CTX 300 SO2 - 10 ppm sensor pack. 6313647 CTX 300 SO2 - 30 ppm sensor pack. 6313648 CTX 300 SO2 - 100 ppm sensor pack. 40 CTX 300 User manual Picture P/N Description 6313649 CTX 300 Cl2 - 10 ppm sensor pack. 6313650 CTX 300 H2 - 30 ppm sensor pack. 6313651 CTX 300 H2 - 100 ppm sensor pack. 6313652 CTX 300 HCL - 30 ppm sensor pack. 6313653 CTX 300 HCL - 100 ppm sensor pack. 6313654 CTX 300 HCN - 10 ppm sensor pack. 6313655 CTX 300 HCN - 30 ppm sensor pack. 6313656 CTX 300 NH3 - 100 ppm sensor pack. 6313657 CTX 300 NH3 - 1000 ppm sensor pack. 6313893 CTX 300 NH3 - 0-5000 ppm sensor pack. 6313675 CTX 300 HF - 10 ppm sensor pack. 6313676 CTX 300 O3 - 1 ppm sensor pack. 6313677 CTX 300 PH3 - 1 ppm sensor pack. 6313919 CTX 300 PH3 - 1000 ppm sensor pack. 6313860 CTX 300 F2 - 1 ppm sensor pack. 6314183 CTX 300 CH2O - 50 ppm sensor pack. 6 314 185 CTX 300 ASH3 - 1 ppm sensor pack. 6313834 CTX 300 SIH4 - 50 ppm sensor pack. 6313678 CTX 300 ClO2 - 3 ppm sensor pack. 6313833 CTX 300 COCl2 - 3 ppm sensor pack. Picture Replacement parts 6323608 Cover without display. 6323609 Cover with display. 6815919 CTX 300 without display label. 6815921 CTX 300 wit display label. 6451466 Display card. 6815923 Localization sticker. 6451465 Motherboard. 6 – Spare parts 41 CSC 300 semiconductor sensors P/N Description 6147868 CTX 300 tool kit. 6322420 Mounting brace and bolts (CTX 300 ceiling mount). 6323607 Gas collector (stainless). 6335919 Calibration kit (humidifier filter + pipe). 6335918 Humidifier filter. Replacement sensors 6313544 Sensor for R134A, R11, R23, R143A, R404A, R507, R410A, R32, R407C, R408A. 6313545 Sensor for methyl chloride, methylene chloride. 6313546 Sensor for solvents. 6313547 Sensor for R22, R12. 6313464 Sensor for VOC. Replacement parts 6451396 Motherboard. 6143502 PG9 cable gland. 42 CTX 300 User manual Picture CTX 300 – CO2 sensors1 P/N Description 6147868 CTX 300 tool kit. 6451618 Motherboard. 6351233 Linearization card. 6799188 Gas introduction device. Picture Replacement sensors 6451612 CO2 - 0 - 1 % sensor. 6451611 CO2 - 0-5 % or 0-10 % sensor. 6451610 CO2 - 0 - 50 % sensor. Replacement parts 6815923 Localization sticker. 6851919 Self-adhesive front panel. 6143502 PG9 cable gland. 1 CTX 300 CO2 detector delivered before July 2015 6 – Spare parts 43 44 CTX 300 User manual Chapter 7 | Certification The following page reproduces the EC declaration of conformity. 7 - Certification 45 46 CTX 300 User manual 7 - Certification 47 48 CTX 300 User manual Chapter 8 Technical specifications Enclosure. Polycarbonate housing. Function. Detector-transmitter Highly visible backlight display unit (optional, gas dependent) In operation: green color (on CTX 300 : 3-wire) Failure / maintenance: yellow color 2 wires – CTX 300 without display unit 3 wires – CTX 300 with display unit PG9 cable gland (outer diameter 6 to 11 mm) Display Indicator lights Link Cable entry Power supply Power consumption 15 to 32 V DC CTX 300 without display unit: 27 mA CTX 300 with display unit: 110 mA Infrared or semiconductor versions: 100mA Operating temperature -40°C to + 50°C, 40°F to + 122°F sensor dependent Sealing IP 54, NEMA 3 & 3R Weight 520 g Dimensions 130 x 136 x 69 (l x h x d) in mm ; (5.12" x 5.35" x 2.72") Certification EMC Impedance CCSA – Class 4812 10 – Signal Appliances-Detectors CSAUS – Class 4812 86 - Signal Appliances-Miscellaneous Type 1 according to EN 50270:06 32 ohms max loop for CTX 300 with display unit and for solid states and CO2 sensor versions 128 ohms max loop for CTX 300 without display unit 8 – Technical specifications 49 Range (ppm) Operating temperature Relative humidity uncondensed Accuracy (at PA full scale) Life span (in month) T(50) (seconds) Type of sensor 30.0% 30.0% 100% -20°C to +50°C -40°C to +50°C +5°C to +40°C 10% to 95% RH 10% à 95% RH 10% to 95% RH +/-1.5% +/-1.5% +/-1.5% 28 60 36 10 10 <20 EC 100 300 1000 1.00% 10.0% -20°C to +50°C -20°C to +50°C -20°C to +50°C -20°C to +50°C -20°C to +50°C 10% to 95% RH 10% to 95% RH 10% to 95% RH 10% to 95% RH 10% to 95% RH +/-1.5% +/-1.5% +/-1.5% +/-1.5% +/-1.5% 48 48 48 48 48 15 15 15 <20 <20 CO2 IR 1% 5% 10% 50% -30°C to +45°C -30°C to +45°C -30°C to +45°C -30°C, to +45°C 5% to 95% RH 5% to 95% RH 5% to 95% RH 5% to 95% RH +/-2% +/-2% +/-2% +/-2% 60 60 60 60 70(T90) 70(T90) 70(T90) 70(T90) H2S EC 30.0 100 1000 -20°C to +50°C -20°C to +50°C -20°C to +50°C 10% to 95% RH 10% to 95% RH 10% to 95% RH +/-1.5% +/-1.5% +/-1.5% 36 36 36 15 15 15 NO EC 100 300 1000 -20°C to +50°C -20°C to +50°C -20°C to +50°C 10% to 95% RH 10% to 95% RH 10% to 95% RH +/-1.5% +/-1.5% +/-1.5% 36 36 36 15 15 15 NO2 EC 10.0 30.0 -20°C to +50°C -20°C to +50°C 10% to 95% RH 10% to 95% RH +/-1.5% +/-1.5% 24 24 20 20 SO2 EC 10.0 30.0 100 -20°C to +50°C -20°C to +50°C -20°C to +50°C 10% to 95% RH 10% to 95% RH 10% to 95% RH +/-1.5% +/-1.5% +/-1.5% 36 36 36 15 15 15 Cl2 EC 10.0 -20°C to +50°C 10% to 95% RH +/-1.5% 24 50 H2 EC 2000 2.0% -20°C to +50°C -20°C to +50°C 10% to 95% RH 10% to 95% RH +/-1.5% +/-1.5% 24 24 50 50 HCl EC 30.0 100 -20°C to +50°C -20°C to +50°C 10% to 95% RH 10% to 95% RH +/-1.5% +/-1.5% 18 18 50 50 HCN EC 10.0 30.0 -20°C to +50°C -20°C to +50°C 10% to 95% RH 10% to 95% RH +/-2% +/-2% 24 24 30 30 NH3 EC 100 100 1000 5000 -20°C to +40°C -40°C to +40°C -20°C to +40°C -20°C to +40°C 10% to 95% RH 10% to 95% RH 10% to 95% RH 10% to 95% RH +/-3% +/-3% +/-3% +/-3% 24 24 24 24 <20 <20 <20 <20 ETO EC 30.0 -20°C to +50°C 10% to 95% RH +/-3% 36 50 EC 10.0 -10°C to +30°C 10% to 95% RH +/-3% 12 50 EC 1.00 -20°C to +50°C 10% to 95% RH +/-3% 18 40 Gas EC O2 CO HF O3 50 CTX 300 User manual Gas Type of sensor Range (ppm) Operating temperature Relative humidity uncondensed Accuracy (at PA full scale) Life span (in month) T(50) (seconds) PH3 EC 1.00 -20°C to +50°C 10% to 95% RH +/-3% 12 40 ASH3 EC 1.00 -20°C to +50°C 10% to 95% RH +/-3% 12 40 ClO2 EC 3.00 -20°C to +50°C 10% to 95% RH +/-2% 24 50 COCl2 EC 3.00 -20°C to +40°C 10% to 95% RH +/-1.5% 18 50 Methylene chloride SC 500 -20°C to +55°C 10% to 95% RH 36 40 Methyl chloride SC 500 -20°C to +60°C 10% to 95% RH 36 40 Toluene SC 500 2000 -20°C to +50°C -20°C to +50°C 10% to 95% RH 10% to 95% RH 36 36 20 20 Trichloroethylene SC 500 -20°C to +60°C 10% to 95% RH 36 40 Xylene SC 500 2000 -20°C to +50°C -20°C to +50°C 10% to 95% RH 10% to 95% RH 36 36 20 20 Ethanol SC 500 5000 -20°C to +50°C -20°C to +60°C 10% to 95% RH 10% to 95% RH 36 36 20 20 R12 SC 10000 -20°C to +55°C 10% to 95% RH 36 30 R22 SC 2000 -20°C to +55°C 10% to 95% RH 36 30 R123 SC 2000 -20°C to +55°C 10% to 95% RH 36 30 R134a SC 2000 -20°C to +55°C 10% to 95% RH 36 30 R11 SC 10000 -20°C to +55°C 10% to 95% RH 36 30 R23 SC 10000 -20°C to +55°C 10% to 95% RH 36 30 R143a SC 2000 -20°C to +55°C 10% to 95% RH 36 30 R404a SC 2000 -20°C to +55°C 10% to 95% RH 36 30 R507 SC 2000 -20°C to +55°C 10% to 95% RH 36 30 R410a SC 1000 -20°C to +55°C 10% to 95% RH 36 20 R32 SC 1000 -20°C to +55°C 10% to 95% RH 36 20 +/-15% relative to alarm threshold EC : Electrochemical IR : Infrared SC : Semiconductor 8 – Technical specifications 51 52 CTX 300 User manual Chapter 9 | Annex Indications for calibrating the CTX 300 SC This information relates to the CTX 300 semiconductor. P/N Gas types Measurement range After sale service standard gas 6313545 Methane CH4 100% LEL 20 % LEL 1 % CH4 Hydrogen H2 100% LEL 20 % LEL 0.8 % H2 Butane C4H10 100% LEL 20 % LIE LEL 0.37 % C4H10 Propane C3H8 100% LEL 20 % LEL 0.4 % C3H8 Methyl Chloride CH3Cl 500 ppm 50 ppm CH3Cl 2000 ppm H2 = 190 ppm ± 25ppm Methylene chloride CH2Cl2 500 ppm 100 ppm CH2CL2 100 ppm CO = 80ppm ± 15 ppm Trichloroethylene C2HCl3 500 ppm 75 ppm Trichloroethylene 300 ppm CO = 120 ppm ± 35ppm Toluene C6H5CH3 2 000 ppm 100 ppm Toluene 300 ppm CO = 330ppm ± 50ppm Xylene C6H4 (CH3)2 2 000 ppm 100 ppm Xylene 300 ppm CO = 330ppm ± 50ppm Ethanol C2H5OH 5 000 ppm 1000 ppm Ethanol 1000ppm H2 = 880ppm ± 150ppm Freon R12 1 % volume 1000 ppm R12 0.5%CH4=overscale Freon R22 2000 ppm 1000 ppm R22 0.5% CH4 = 750ppm ± 200ppm Freon R134A 2000 ppm 1000 ppm R134A 0.5% CH4 = 2000ppm ± 500ppm Freon R11 1% volume 1000 ppm R134A = 150 ppm 0.5% CH4=overscale Freon R23 1% volume 1000 ppm R22 = 4500ppm 0.5% CH4 = 2800ppm ±800ppm 6313546 6313547 6313544 Test gas 9 – Annex 53 CTX 300 overview Figure 41: CTX 300 with sensor pack and display – overview. 54 CTX 300 User manual Figure 42: CTX 300 – overview. 9 – Annex 55 Figure 43: CTX 300 semiconductor– overview. 56 CTX 300 User manual Figure 44: CTX 300 infrared – 1% volume CO2 – overview. 9 – Annex 57 Figure 45: CTX 300 infrared – 5% volume CO2 – overview. 58 CTX 300 User manual Figure 46: CTX 300 infrared – 10% volume CO2 – overview. 9 – Annex 59 Figure 47: CTX 300 infrared – 50% volume CO2 – overview. 60 CTX 300 User manual 61 63 The Fixed Gas Detection Experts EUROPEAN PLANT AND OFFICES Z.I. Est – rue Orfila CS 20417 – 62027 Arras Cedex FRANCE Tél: +33 (0)3 21 60 80 80 – Fax: +33 (0)3 21 60 80 00 Website: http://www.oldhamgas.com AMERICAS Tel: +1 713-559-9280 Fax: +1 281-292-2860 [email protected] ASIA PACIFIC Tel: +86-21-3127-6373 Fax: +86-21-3127-6365 [email protected] EUROPE Tel: +33-321-608-080 Fax: +33-321-608-000 [email protected]
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project