SCA3000 DEMO KIT User Manual

SCA3000 DEMO KIT User Manual
Doc.Nr. 8259300.10
SCA3000 DEMO KIT
User Manual
SCA3000 DEMO KIT
User Manual
TABLE OF CONTENTS
1 Introduction .........................................................................................................................3
2 Quick start for using the SCA3000 DEMO KIT..................................................................3
3 Hardware..............................................................................................................................4
4 GUI software ........................................................................................................................4
4.1
Resetting GUI and µC ..............................................................................................................11
4.2
Uninstalling the GUI and USB driver......................................................................................11
5 Advanced data logging.....................................................................................................11
6 SCA3000 current consumption measurement with DEMO KIT .....................................13
7 USB interface board circuit diagram ...............................................................................14
8 USB interface board PWB layout .....................................................................................17
9 Troubleshooting ................................................................................................................18
9.1 Known Issues...........................................................................................................................20
9.1.1 Floating SCA3000 CLK-pin .................................................................................................20
9.1.2 Changing the serial bus type...............................................................................................20
9.1.3 Interference from USB communication ...............................................................................20
10 Document Revision History .............................................................................................21
11 Contact Information ..........................................................................................................21
VTI Technologies Oy
www.vti.fi
Doc.Nr. 8259300.10
2/21
Rev.0.10
SCA3000 DEMO KIT
User Manual
1
Introduction
SCA3000 demo demonstrates the SCA3000 component functionality and the component key
properties. This document describes how to install the required software and how to use the
SCA3000 demo board and Graphical User Interface (GUI) software version 1.1.
SCA3000 demo consists of:
• SCA3000 sensor soldered on chip carrier PWB (see Figure 1 on next page)
• USB interface card (see Figure 1 on next page)
• USB cable
• GUI software running on PC
The SCA3000 DEMO KIT supports all SCA3000 series sensors: SCA3000-D01, SCA3000-D02,
SCA3000-E01, SCA3000-E02 and SCA3000-E04. The evaluation boards (SCA3000 PWBs) are
compatible with the SCA3000 DEMO KIT.
SCA3000 demo runs on Windows XP and 2000, it requires USB connection for data transfer.
Demo is powered from USB port.
2
Quick start for using the SCA3000 DEMO KIT
Please follow the steps below:
1. Insert CD-ROM
2. Setup the hardware
- Connect the demo kit to PC's USB port
3. Install the USB driver, after the PC has found the device
- When the PC detects the new USB device, do not let Windows to detect the driver,
address the USB driver from folder:
"CD-ROM\SCA3000 demo - Virtual Com Port Drivers\”
- NOTICE, if you have already installed the SCP1000 demo to your computer,
please check that the latency timer parameter is 5 ms. In case the latency timer
value is greater than 5 ms, the SCA3000 DEMO KIT GUI will not work (more
detailed instructions in section 9)
4. Install the GUI software
- Install the GUI software by running the “setup.exe" from folder:
CD-ROM\SCA3000 demo - ver 1.1 - Installer
- Do not change the installation destination
5. Start the GUI software
- From Start → Programs → SCA3000-USB-DEMO-VER-1.1 →
SCA3000-USB-DEMO-VER-1.1
When using the SCA3000 DEMO KIT with GUI software:
• The DEMO KIT should be connected to PC before the GUI software is started
• Exit the GUI software before unplugging the DEMO KIT from PC
• After GUI software is stopped, the DEMO KIT can be unplugged from PC (DEMO KIT uses
virtual serial port driver, so it can not be found as a USB device).
VTI Technologies Oy
www.vti.fi
Doc.Nr. 8259300.10
3/21
Rev.0.10
SCA3000 DEMO KIT
User Manual
3
Hardware
The SCA3000 DEMO KIT USB interface board (black PWB) and SCA3000 PWB (red PWB) are
shown in Figure 1. The USB interface card converts the USB interface to SPI or I2C interface.
SCA3000 sensor is soldered on PWB which is connected to interface board.
Green led: data transfer
SCA3000 sensor
Test points for
SCA3000 sensor
Idd measurement
Red led: demo
powered from USB
Demo reset
Figure 1. SCA3000 demo USB interface board and SCA3000 PWB.
4
GUI software
SCA3000 DEMO KIT is controlled via USB serial port by GUI software.
The GUI software has five different display modes. The SCA3000 sensor can be set to:
- normal measurement mode,
- normal measurement mode with free fall detection enabled and
- motion detection mode.
The interrupt detected due free fall or motion is indicated by led indicator and sound (if PC sounds
are enabled). Once interrupt is detected, the interrupt has to be cleared by user by pressing the red
led. The led appears on display only when the interrupt is detected.
The five different GUI displays and start up screens are presented below.
VTI Technologies Oy
www.vti.fi
Doc.Nr. 8259300.10
4/21
Rev.0.10
SCA3000 DEMO KIT
User Manual
Screen capture of the GUI is presented in Figure 2.
2.
1.
3.
4.
5.
6.
7.
8.
9.
13.
11.
12.
10.
Figure 2. SCA3000 DEMO KIT Graphical User Interface
Table 1. The numbered items in Figure 2.
Item
1
2
3
4
Resultant acceleration ON / OFF ( Res =
5
6
7
8
Save acceleration data in to text file.
Freeze image, start / stop the scrolling window, [Page-Up] button also.
Zero gravitation ON / OFF.
Open / close the window extension with arrow button (available only in
SCROLL display).
Pull down menu for acceleration [g] range (Y-axis).
Selected sensor type and GUI software version number.
Averaging ON / OFF, number of samples for averaging.
Pull down menu for SCA3000 measurement mode
Pull down menu for GUI display mode
9
10
11
12
13
VTI Technologies Oy
www.vti.fi
Description
Temperature display, if temperature information is available for the
sensor.
Exit software, [Esc]-button also.
Data overflow; if the indicator is red, the acceleration register has overflow
→ measured acceleration is out of measuring range.
Doc.Nr. 8259300.10
x 2 + y 2 + z 2 ).
5/21
Rev.0.10
SCA3000 DEMO KIT
User Manual
If more than one USB serial port devices
are connected to PC, user must select the
correct USB SERIAL PORT from pop-up
window (Figure 3). If user does not know
the correct USB serial port number, please
disconnect all other USB serial port
devices from PC and restart the GUI
software.
Figure 3. USB serial port selection pop-up window.
User needs to select the correct product
type from PRODUCT SELECTION pop-up
window (Figure 4). SCA3000-D01 is
selected by default, product type can be
found from top SCA3000 component, see
Figure 1. Product selection affects on the
used serial communication (SPI / I2C) as
well as the sensor output scaling to
acceleration.
Figure 4. Product selection pop-up window.
SCROLL, continuously scrolling X, Y, Z
and resultant accelerations, see Figure 5.
Acceleration is presented in [g]. User can:
- change the acceleration scale
- freeze the scrolling image
- change the averaging factor
- set averaging OFF
- save acceleration data into file
- enable resultant scrolling
- detect which axis caused the
interruption in motion detection mode
(by clearing the interrupt)
Most of the actions/controls listed above
are in the extension part of the window,
which can be accessed by pressing the
arrow button (see Figure 2 and Table 1).
Figure 5. Scroll display with detected free fall.
The red led in the lower left corner in
Figure 5 indicates the detected free fall. By
pressing the red led the interrupt is cleared
by reading the INT_STATUS register.
The pull down menu for different displays
is disabled when free fall or motion
detector mode is activated.
VTI Technologies Oy
www.vti.fi
Doc.Nr. 8259300.10
6/21
Rev.0.10
SCA3000 DEMO KIT
User Manual
The red led in the lower left corner in
Figure 6 indicates the detected motion. By
pressing the red led the interrupt is cleared
by reading the INT_STATUS register.
The INT_STATUS register contains the
information of the interrupt cause. In Figure
6 Y- and Z-axis acceleration triggered the
motion detector in previous time.
The pull down menu for different displays
is disabled when free fall or motion
detector mode is activated.
Figure 6. Scroll display with detected motion.
BUBBLE LEVEL, two displays that show
tilt angle, see Figure 7. Angle calculation is
performed in GUI, not in SCA3000 sensor.
SCA3000 sensor
enabled / disabled.
averaging
can
be
Figure 7. Bubble level display.
VTI Technologies Oy
www.vti.fi
Doc.Nr. 8259300.10
7/21
Rev.0.10
SCA3000 DEMO KIT
User Manual
3D, 3 dimensional display with projections
of each axis acceleration, see Figure 8.
The minimum and maximum resultant
accelerations as well as the current
resultant acceleration are displayed on the
right side of the graph. Minimum and
maximum displays can be cleared by
pressing the "Reset" button.
Figure 8. 3D display.
DATA LOGGER, display where user can:
- log data (maximum log time 5 s)
- view the logged data in [g]
- view the demonstrator speed as a
function time (speed [m/s] is derived by
integrating the acceleration data)
- view the inertial navigation results
(distance [m] as a function of time is
derived by integrating the acceleration
data twice)
To start the data logging press the "Start
measurement" button. The actual data
logging starts when the green "Measuring
data" indicator lights up in the upper right
corner of the window. Data is logged for
predefined time period (“Measure time”).
The results are calculated afterwards. The
green "Measuring data" indicator is
activated also during the result calculation.
Figure 9. Data logger display.
The resultant (acceleration [g], speed [m/s] and distance [m]) is calculated from the respective
3-axis results as follows:
Res = x 2 + y 2 + z 2
Please notice that inertial navigation contains six degrees of freedom and 3-axis accelerometer can
handle only three degrees of freedom (rotations and tilting can not be detected when inertial
navigation is performed only by 3-axis accelerometer).
VTI Technologies Oy
www.vti.fi
Doc.Nr. 8259300.10
8/21
Rev.0.10
SCA3000 DEMO KIT
User Manual
REGISTER CONFIG display offers user
access in to SCA3000 sensor internal
registers. Registers can be read and
written. The written data format can be
changed between binary and hexadecimal
by pressing the "Bits / Hex" button.
User
can
read
automatically
all
configuration registers by pressing the
“Save reg content” button. The results are
saved into file and they can be viewed
from “Register content” tab as well.
Figure 10. SCA3000 register configuration display.
SPI frame format for each operation can
be viewed from “Waveform” tab (see
Figure 11).
Figure 11. SCA3000 SPI waveforms in register
configuration display.
VTI Technologies Oy
www.vti.fi
Doc.Nr. 8259300.10
9/21
Rev.0.10
SCA3000 DEMO KIT
User Manual
SETUP display presents some operational
parameters of selected component type,
please refer to component specific
documentation for further information.
“Data transfer wait [ms]” is the delay in GUI
software between the successive data
readings from virtual serial port. If the GUI
sw does not run properly, user can try if
increasing this delay results in better GUI
software functionality.
The used virtual serial COM port number
can be viewed from "Serial port" display.
This information is needed if the SCA3000
DEMO KIT is used without the GUI
software, see further details from section 5.
In this example the SCA3000 DEMO KIT
uses COM4 serial port.
Figure 12. Setup display.
RESET DEMO initialises the GUI software.
µC software version is presented also. GUI
revision 0.16.5 can be executed with µC
software version 0.9.95. SCROLL display
opens after RESET by default.
Figure 13. Reset demo display.
VTI Technologies Oy
www.vti.fi
Doc.Nr. 8259300.10
10/21
Rev.0.10
SCA3000 DEMO KIT
User Manual
4.1
Resetting GUI and µC
SCA3000 DEMO KIT GUI software can be reinitialised by selecting the “Reset demo” display from
pull down menu, see Figure 13.
µC can be resetted by exiting from the GUI and then pressing the reset button (Figure 1) on USB
interface board.
4.2
Uninstalling the GUI and USB driver
The GUI software and the USB driver (FTDI Serial Converter Driver) can be removed from
Windows Control Panel Add/Remove Programs. Please notice that removing the FTDI Serial
Converter Driver (USB driver) may affect on functionality of some other programs (such as
SCP1000 demo kit GUI).
5
Advanced data logging
Acceleration data can be saved from GUI software by pressing the “Save to file” button (Figure 2).
Data can be logged also by using the Windows HyperTerminal software and macro language that
is used to control the µC of the SCA3000 DEMO KIT.
Please notice that GUI software and Windows HyperTerminal software can not be open at the
same time. Follow the steps below to start the data logging:
1. Connect SCA3000 DEMO KIT with USB cable to PC
2. Open GUI software to see the correct COM port number (SETUP display, see Figure 12).
3. Close the GUI software.
4. Open Windows HyperTerminal software from CD-ROM:
− “SCA3000_demo_HyperTerminal_connection.ht”, or
− see detailed serial communication settings from Table 2.
5. Press demo reset button (see Figure 1). SCA3000 DEMO KIT sends an info text to
HyperTerminal (see Figure 14). If the HyperTerminal software is unable to connect the
SCA3000 DEMO KIT or the info text does not appear,
,
- Press disconnect
,
- change the COM port number to correct from port properties
,
- press connect
- press reset button on SCA3000 DEMO KIT.
until info text appears to HyperTerminal screen (see Figure 14).
6. After the info text appears on HyperTerminal, send text file “SCA3000_data_logger.txt”
from CD-ROM (“Transfer” pull down menu → “Send Text File…” → browse for
SCA3000_data_logger_macro.txt)
7. The text file is actually a macro that runs in an endless loop. The macro sends 3-axis
acceleration data in hex format to HyperTerminal (see Figure 15). Example of data format:
0x1ef0,0x0130,0x01f0,Z-Y-X
where “0x” indicates for hex format, and “Z-Y-X” the axis order. The Z-axis hex output is
1EF0, which is ‘0001 1110 1111 0000’ in binary format.
8. The data can be stored by capturing the data in to file:
“Transfer” pull down menu → “Capture Text…” → save captured data into wanted file and
folder.
9. Data capturing can be stopped from:
“Transfer” pull down menu → “Capture Text…” → “Stop”
Macro language is used to control the SCA3000 DEMO KIT. It can be also used to configure the
SCA3000 sensor. For more detailed information of macro language, please refer to “SCA3000
DEMO KIT macro language description 8259200”.
VTI Technologies Oy
www.vti.fi
Doc.Nr. 8259300.10
11/21
Rev.0.10
SCA3000 DEMO KIT
User Manual
Connection properties
2. Connect
1. Select COM port
Figure 14. Windows HyperTerminal with SCA3000 demo info text.
If the pre-configured HyperTerminal connection is not available (the CD-ROM), the HyperTerminal
connection can be opened also from:
→ Start → Programs → Accessories → Communications → HyperTerminal
The communication settings are presented in Table 2 below
Table 2. SCA3000 DEMO KIT serial communication settings.
Parameter
Bits per second
Data bits
Parity
Stop bits
Flow control
Value
230400
8
None
1
None
The correct COM port number depends on the PC and used USB port.
VTI Technologies Oy
www.vti.fi
Doc.Nr. 8259300.10
12/21
Rev.0.10
SCA3000 DEMO KIT
User Manual
Figure 15. SCA3000 demo output during data logging.
6
SCA3000 current consumption measurement with DEMO KIT
The current consumption of the SCA3000 sensor can be calculated by measuring the voltage drop
over the resistor R34 (470 Ω, 1% tolerance). Voltage drop can be measured from test points TP5
and TP6, see DEMO KIT USB interface board circuit diagram in Figure 18 (PCB design
VTI 29393 rev B0).
The offset current consumption of the DEMO KIT hardware depends on used serial communication
(SPI vs. I2C). The offset current consumption according to serial communication type is presented
in Table 3 below.
Table 3. Offset current consumption of the SCA3000 DEMO KIT HW.
Serial interface
SPI
I2C
Offset current consumption
~950 µA (Voffset = 444 mV)
~200 µA (Voffset = 94 mV)
The offset current consumption can also be measured by measuring the voltage drop over the
resistor R34 (TP5 and TP6, see Figure 18) when SCA3000 PWB is not connected to USB interface
board.
SCA3000 current consumption can be calculated
⎛ V − Voffset
Idd = ⎜⎜ drop
⎝ 470 Ω
⎞
⎟⎟,
⎠
(1)
where Vdrop is the measured voltage drop in [V] (from TP5 to TP6, see Figure 18), Voffset is the
measured offset current consumption (from TP5 to TP6, see Figure 18), alternatively the values
from Table 3 can be used. Idd is the SCA3000 current consumption in [A].
The difference in offset current consumption is due the pull up resistor in SCK/SCL line (R2 in
Figure 17). When using SPI-bus, the µC software drives the SCK/SCL line low when there is no
communication, which results in increase in DEMO KIT offset current consumption (current through
resistor R2 in Figure 17 from DVDD to GND). When I2C is used, the µC releases the SCK/SCL line
when there is no communication.
VTI Technologies Oy
www.vti.fi
Doc.Nr. 8259300.10
13/21
Rev.0.10
SCA3000 DEMO KIT
User Manual
7
USB interface board circuit diagram
SCA3000 demo USB interface board circuit diagram is presented in following pages.
Figure 16. SCA3000 DEMO KIT USB interface board circuit diagram (sheet USB).
VTI Technologies Oy
www.vti.fi
Doc.Nr. 8259300.10
14/21
Rev.0.10
SCA3000 DEMO KIT
User Manual
Figure 17. SCA3000 DEMO KIT USB interface board circuit diagram (sheet µC).
VTI Technologies Oy
www.vti.fi
Doc.Nr. 8259300.10
15/21
Rev.0.10
SCA3000 DEMO KIT
User Manual
Figure 18. SCA3000 DEMO KIT USB interface board circuit diagram (sheet power).
VTI Technologies Oy
www.vti.fi
Doc.Nr. 8259300.10
16/21
Rev.0.10
SCA3000 DEMO KIT
User Manual
8
USB interface board PWB layout
SCA3000 DEMO KIT USB interface board PWB layout and silkscreen is presented below.
Figure 19. SCA3000 DEMO KIT USB interface board PWB layout.
Figure 20. SCA3000 DEMO KIT USB interface board silkscreen.
VTI Technologies Oy
www.vti.fi
Doc.Nr. 8259300.10
17/21
Rev.0.10
SCA3000 DEMO KIT
User Manual
9
Troubleshooting
Due to many PC environments, the interoperability can be limited. The SCA3000 DEMO KIT has
been tested with DELL laptops (Latitude D600, D610, D410) and desktop PCs with Win2000 and
WinXP operating system. If the SCA3000 DEMO KIT does not work properly or it’s operation is
limited, the following items may help to sort the problems out:
• Stop the GUI software, press the reset button program on demo USB interface board (see
Figure 1), re-start the GUI again.
• The wait time in data transfer can be in increased on “SETUP” display (GUI software pull
down menu, see Figure 12).
• SCA3000 demo may not work properly if your PC has multiple USB serial ports installed.
Please remove all other USB serial port devices (including SCP1000 demo).
• Close Windows HyperTerminal software, if you have used it.
• Check that USB driver LATENCY TIMER parameter is 5ms. Plug the demo USB cable in
to PC and follow the steps (and screen captures) below:
1. Open control panel and select “SYSTEM”
2. Select “DEVICE MANAGER” from “HARDWARE” tab
3. Select “USB SERIAL PORT” from the list, right mouse click and select
“PROPERTIES"
4. Select “ADVANVED” from the USB Serial port Properties
5. Set the “LATENCY TIMER” to 5 ms (the 16ms default value is too slow for SCA3000
DEMO KIT).
6. Press “OK” to all windows.
7. Restart the GUI software.
8. NOTICE! If the SCP1000 USB demo does not work properly with this 5 ms latency
timer value, the value needs to be changed back to 16 ms.
Start → Settings → Control panel
1.
2.
VTI Technologies Oy
www.vti.fi
Doc.Nr. 8259300.10
18/21
Rev.0.10
SCA3000 DEMO KIT
User Manual
3.
4.
5.
VTI Technologies Oy
www.vti.fi
Doc.Nr. 8259300.10
19/21
Rev.0.10
SCA3000 DEMO KIT
User Manual
9.1
9.1.1
Known Issues
Floating SCA3000 CLK-pin
With MCU software version 0.9.95 the CLK-pin of SCA3000 (pin #4) is configured to floating
instead of GND. SCA3000 will operate normally, but floating the CLK-pin may cause bigger current
consumption values for SCA3000 than normally. If such thing is noticed, the CLK line (marked also
on the silkscreen of the USB interface card) can be grounded.
This feature is fixed with MCU software version 0.9.95-r1.
9.1.2
Changing the serial bus type
The MCU needs to be reset (by pressing the reset button, see Figure 1) when changing between
the two available serial bus types (SPI & I2C). This thing can happen when user changes the used
SCA3000 component type.
9.1.3
Interference from USB communication
Capacitor C22 (Figure 16) connects the USB cable connector body to the GND net of the USB
interface board. The capacitor value is updated from 470 pF to 100 nF in order to decrease the
interferences in USB supply voltage (USB_VCC net in Figure 16). USB serial communication
causes the interference in to the supply voltage provided by USB port.
The value of the capacitor C22 is 100 nF in the SCA3000 DEMO KITs that have been assembled
since end of June 2006.
VTI Technologies Oy
www.vti.fi
Doc.Nr. 8259300.10
20/21
Rev.0.10
SCA3000 DEMO KIT
User Manual
10 Document Revision History
Version
Date
Change Description
0.06
19.04.2006
0.07
12.05.2006
0.08
15.06.2006
0.09
28.06.2006
0.10
13.09.2006
Updated:
- document template,
minor language corrections
Updated:
- USB interface board updated (VTI29393B0), minor changes
Current consumption measurement (section 6)
GUI software version updated from version 0.16.4 to version 1.0 (visual update)
Section "9.1 Known issues" added
Updated:
- Section "9.1 Known issues",
Contact information
GUI software version updated from 1.0 to 1.1. GUI sw ver 1.1 supports also SCA3000-E04
sensors
11 Contact Information
Finland
(head office)
VTI Technologies Oy
P.O. Box 27
Myllynkivenkuja 6
FI-01621 Vantaa
Finland
Tel. +358 9 879 181
Fax +358 9 8791 8791
E-mail: [email protected]
Germany
VTI Technologies Oy
Branch Office Frankfurt
Rennbahnstrasse 72-74
D-60528 Frankfurt am Main,
Germany
Tel. +49 69 6786 880
Fax +49 69 6786 8829
E-mail: [email protected]
Japan
VTI Technologies Oy
Tokyo Office
Tokyo-to, Minato-ku 2-7-16
Bureau Toranomon 401
105-0001
Japan
Tel. +81 3 6277 6618
Fax +81 3 6277 6619
E-mail: [email protected]
China
VTI Technologies Shanghai Office
6th floor, Room 618
780 Cailun Lu
Pudong New Area
201203 Shanghai
P.R. China
Tel. +86 21 5132 0417
Fax +86 21 513 20 416
E-mail: [email protected]
VTI Technologies Oy
www.vti.fi
Doc.Nr. 8259300.10
USA
VTI Technologies, Inc.
One Park Lane Blvd.
Suite 804 - East Tower
Dearborn, MI 48126
USA
Tel. +1 313 425 0850
Fax +1 313 425 0860
E-mail: [email protected]
To find out your local sales
representative visit www.vti.fi
21/21
Rev.0.10