advertisement
Dental-
Information
S i r o n a D e n t a l S y s t e m s F a b r i k s t r a s s e 3 1 D - 6 4 6 2 5 B e n s h e i m
August 2005
The topics in this issue:
Seminar and training dates
Training for dental sales representatives
Treatment centres
C8 + /ProFeel + : instrument foot switch now available as a repair-exchange part
M1/E: test certificate for amalgam separator no longer required
M1, model 94: changes to the range of spare parts
Patient communication
New version of the SIVISION PC software
Handpieces
ImplantSystem: software update version 2.01
Hygiene
Sirona DAC Universal
HYGIENE CENTER: repair-exchange
CAD/CAM
inLab marketing package now available
New power supply for the milling unit
Delivery times
Status: August 2005
Page 4
Page
Page
Page
Page 7
Page 8
Page
Page
Page
Page
9
12
13
14
Page 15
5
5
6
A 08/2005 − Page 2 August
Topics covered in previous issues
General
Diagnostic system
Credits
General conditions of sale
Price lists
Paintwork and upholstery colours
Quality of products and services
Seminar and training dates
05/05, p. 4; 06/05, p. 3
Treatment centres
General
E generation
+ M1/M1
C1 +
C2
C3
+
+
C4 + /C4 + cart version
C5 +
C6 (outside Germany)
C8/C8 +
ProFeel/ ProFeel
Tray
+
SIROLUX S/Fantastic
Chairs
Patient communication
General
SIROCAM
SIVISION
Handpieces
General
High-speed handpieces
T1 TITAN
T1 LINE
T1 CLASSIC
T2 REVO
SIROSON L
SIROSON S
SIROSONIC
SIROSONIC L
SIROPRO
SIROTOM S
SPRAYVIT
SIRONA motors
SIRONiTi/SIRONiTi starter kits/ SIRONiTi Air +
ImplantSystem
Sterilizers/care systems
General
DAC Universal
HYGIENE CENTER
VALIDATOR Plus
01/05, p. 3; 05/05, p. 5; 06/05, p. 4; 07/05, p. 4
06/05, p. 5; 07/05, p. 5; 08/05, p. 5
01/05, p. 4; 06/05, p. 7
05/05, p. 6; 06/05, p. 5; 08/05, p. 5
01/05, p. 4; 06/05, p. 5
06/05, p. 5
06/05, p. 5
06/05, p. 5; 07/05, p. 4
06/05, p. 5
05/05, p. 7
01/05, p. 4; 06/05, p. 5; 08/05, p. 5
01/05, p. 5; 05/05, p. 6; 06/05, p. 5; 08/05, p. 5
05/05, p. 8
05/05, p. 10; 06/05, p. 8; 08/05, p. 7
05/05, p. 11; 06/05, p. 8
01/05, p. 6; 05/05, p. 10; 06/05, p. 8; 08/05, p. 7
01/05, p. 8; 07/05, p. 6; 08/05, p. 8
07/05, p. 6
01/05, p. 7
07/05, p. 6; 08/05, p. 8
05/05, p. 12; 08/05, p. 9
08/05, p. 9
08/05, p. 12
SIROCLAVE B/VS/S
SIROMINI
SIROSEAL
SIROCLEAN
X-ray
General
HELIODENT DS
Vario HELIODENT
ORTHOPHOS 3
ORTHOPHOS 3 Ceph
ORTHOPHOS 3 DS
01/05, p. 10; 05/05, p. 13; 06/05, p. 9
05/05, p. 13
ORTHOPHOS 5
ORTHOPHOS Plus
ORTHOPHOS Plus Ceph
ORTHOPHOS Plus DS
ORTHOPHOS Plus DS Ceph
SIDEXIS/SIDEXIS XG
USB Box
ORTHOPHOS XG Plus/Ceph Digital
01/05, p. 9; 05/05, p. 13; 06/05, p. 9
01/05, p. 9
05/05, p. 13
CEREC
General 01/05, p. 14; 08/05, p. 14
Software
Training
CEREC 2
CEREC 3 01/05, p. 14
CEREC
CEREC inLab
Scan
Link
01/05, p. 14
General 01/05, p. 13; 06/05, p. 10; 08/05, p. 13 inLab 01/05, inEos 01/05, p. 10; 06/05, p. 10
A 08/2005 − Page 3 August
Seminar and training dates
Training for dental sales representatives
The dates of upcoming training courses are shown in the following table. For further details about the content and goals of the individual courses, please refer to our brochure
“Training Program for Business Partners 2004/2005”.
Basic training Advanced training
Your introduction to the Sirona product portfolio
The fast track to sales success
Treatment centres, handpieces and hygiene systems
X-ray systems (conventional and digital)
29 – 30 August 2005
31 August – 1 September 2005
19 – 20 September 2005
21 – 22 September 2005 inLab 2 September 2005 –
A 08/2005 − Page 4 August
Treatment centres
C8
+
/ProFeel
+
: instrument foot switch now available as a repair-exchange part
With immediate effect, the instrument foot switch is now available as a repair-exchange part. Irrespective of which foot switch you send in, you will receive in exchange the new version with the built-in spray indicator (which is fitted as standard to all new foot switches).
Customers who own a foot switch without a spray indicator have the option of upgrading to the version with a spray indicator at cost price. To this end, we can supply the repair-exchange foot switch (REF. 60 55 649, Pr. Gr. 38) at a special price of
EUR 328.00, excl. VAT. This offer closes on 31 December 2005. The full price will be charged in the case of orders received after this date.
M1/E: test certificate for amalgam separator no longer required
As from August 2005, an amalgam separator test certificate will no longer be supplied together with the following products:
Drive AA2, repair-exchange REF. 33 17 653
REF. 33 20 475 Repair-exchange kit AA2
Previously, it had been necessary to leave a new test certificate in the dental practice in the event of an exchange. This is no longer necessary. The original test certificate remains valid. If you nonetheless require a new test certificate (REF. 33 33 692), please contact our Customer Service Centre.
A 08/2005 − Page 5 August
M1, 94 model: changes to the range of spare parts
The following cover components for the water unit are no longer available:
Designation REF.
Cover, front, coloured
Cover, rear, coloured
Cover (set), coloured
58 94 738
58 94 720
59 14 833
Cover (set), structured
Cover (set), A2S
59 28 437
59 63 327
As an alternative, we can supply the cover set for the 96 model of the M1. The following accessories plus the lower section of the automatic separator must be ordered and installed in addition.
Qty. Designation
1
1
REF.
Cover set for M1 96 water unit, grey-white finish 29 53 164
Alternative: Cover set for M1 96, paint finish.
Please specify the colour shade!
29 56 936
1 Finger protector
1 Angle bracket
1 Spacer pin
3 Threaded bolts
3 Threaded pieces
1 Countersunk screws
3 Spacing tube
1 Lower section of automatic separator
59 66 981
29 57 009
59 16 267
29 56 688
29 56 696
34 23 647
33 80 623
29 53 180
A 08/2005 − Page 6 August
Patient communication
New version of the SIVISION PC software
Version 014 of the SIVISION PC software (REF. 58 85 632) includes two new Windows monitor drivers:
• Driver for “3” monitor (REF. 59 72 034)
The driver for the new “3” monitor (REF. 59 72 034), which went on sale at the beginning of the year, has now been included in our driver file. During the installation process, the monitor is identified as “59 72 034 D3399”. The quick fix recommended in March (i.e. installation of the driver for the monitor “59 72 000 D3399”) can be dispensed with.
• Driver for 19" Monitor (REF. 60 30 634)
The driver file already includes the driver for the new 19" monitor (REF. 60 30 634).
Deliveries of this monitor are scheduled to commence in August 2005. During the installation process, the monitor is identified as "60 30 634 D3481”.
Further information about installation and configuration is contained in the relevant installation instructions (REF. 59 11 321). These instructions are also available on the
CD.
A 08/2005 − Page 7 August
Handpieces
ImplantSystem: software update version 2.01
For technical reasons, contra-angle handpieces differ in terms of their power output.
There are two possibilities for ensuring the right torque at the preparation site:
1.) Calibration of a predetermined torque setting on the drive unit.
2.) The deployment of a software program which is specifically adapted to the handpiece (ImplantSystem).
The torque setting on the ImplantSystem can be guaranteed in combination with the following handpieces:
Handpieces with the gear ratio 1:1
ATR-20S (the 20:1 handpiece so far supplied by ATR)
IMPLANT 20:1
IMPLANT 80:1
For this reason, we have changed the step-down setting options on the control panel
(“Reduction” key) as follows:
1:1
20s:1 for ATR-20 S
20i:1 for IMPLANT 20:1
80:1 for IMPLANT 80:1
IMPLANT handpieces
The drive unit (e.g. ImplantSystem) and the handpiece (e.g. IMPLANT) must be seen as an integrated system. For this reason, each handpiece is accompanied by the following information:
“To fulfill the requirement for the correct torque at the bur, please check if your unit can be used with handpieces of Sirona (IMPLANT 20:1, IMPLANT 80:1) or ATR (ATR-20i,
ATR-80i). For this purpose a software update may be available so far the software is not already installed. Please have a look to the user manual if the handpieces are listed or check the software version which should be 2.01 or higher.
The handpieces are tested with the following units:
ATR ATR
ATR ATR 5000 Plus
ATR ImplaNiti
Sirona ImplantSystem
5000
For further information, please contact your local dealer or the manufacturer of the unit.”
A 08/2005 − Page 8 August
Hygiene
Sirona DAC Universal
The DAC Universal is a multifunctional autoclave system for the cleaning, sterilization and lubrication of straight, contra-angle and high-speed handpieces in a single operation.
Deliveries will commence in the 34th calendar week.
According to the recommendations of the Robert Koch Institute, dental handpieces should be categorized as semi-critical/critical medical products. As they contain voids, dental handpieces are difficult to clean and sterilize. For this reason, Class B autoclaves with a multi-stage pre-vacuum are the recommended method of sterilization. However, the prolonged sterilization cycle – coupled with the labour-intensive and error-critical manual cleaning and lubrication of the handpieces – has a negative impact on practice workflows. This also entails significant investment and maintenance costs.
The DAC Universal eliminates these problems. It takes a mere 12 minutes to clean, lubricate and sterilize six dental handpieces. The DAC Universal is a Class S sterilizer conforming to EN 13060 and has been certified and validated by the Danish State
Hygiene Institute.
The Robert Koch Institute recommends the automated processing of handpieces as a way of eliminating errors and cross-contamination risks for patients and staff.
A 08/2005 − Page 9 August
The DAC Universal is geared to a broad spectrum of different configurations (see diagram).
Take this opportunity to create a seamless infection control chain in the dental practice.
The DAC Universal is equipped with:
• an instrument holder including 6 adapters (the specific adapter type must be specified at the time of ordering)
• 1 container of care concentrate
• Installation set with waste water container, compressed air connection and air filter
DAC Universal, REF. 60 51 630, EUR 5,490.00, excl. VAT, Pr. Gr. 92
Technical specifications:
Energy supply
Water (for sterilization and disinfection)
Consumption
Air connection (dry air)
Dimensions
Water container
Oil container
Documentation
Weight
90 – 250 V, 50/60 Hz, approx. 1,100 W
Demineralized water, max. 3.0 µS
Approx. 330 ml per cycle < 3.0 µS
In the event of inadequate water quality,
(> 3.0 µS/cm) an error message is shown on the display
Input pressure: 5.0 – 8.0 bar
Max. short-term air consumption: approx. 90 Nl/min. at 5 bar
H = 350/600 mm, W = 360 mm,
D = 370 mm +100 mm
2 litres
250 ml
Standard RS 232 interface
Approx. 27 kg
A 08/2005 − Page 10 August
Accessories:
Adapters for turbines
Sirona turbine adapter, complete
KaVo turbine adapter, complete
W&H turbine adapter, complete
W&H turbine adapter – US model, complete
Bien Air turbine adapter, complete
Castellini turbine adapter, complete
NSK Phateleus adapter, complete
NSK VIP II/Pana QD adapter, complete
Lares turbine adapter, complete
Midwest Q-coupler adapter, complete
Midwest adapter, complete
Midwest XGT/Stylus adapter, complete
STAR swivel adapter for Star motor, complete
STAR attachment adapter, complete
Morita PAR-DI turbine adapter, complete
Morita PAR-O turbine adapter, complete
60 51 697
60 51 655
60 51 671
60 51 689
60 51 713
60 51 762
60 51 804
60 51 812
60 51 838
60 51 846
60 51 853
60 51 879
60 51 887
60 51 895
60 51 911
60 51 929
Yoshida turbine adapter, complete
Micro-Mega turbine adapter, complete
60 51 937
60 51 945
Borden adapter, 2/3 hole, complete 60 51 861
Adapters for straight and contra-angle handpieces:
INTRAmatic® adapter with push-button, complete 60 51 648
Sirona TE/Classic adapter, complete
KaVo/Bien Air adapter, complete
60 51 705
60 51 663
Midwest adapter for Rhino/Shorty, complete 60 51 903
Care concentrate
Water softening tablets (100 pcs.)
Printer for DAC Universal
(for documenting the sterilization cycles)
Printer ribbon (2 cartridges)
Printer paper (5 rolls)
Basket with cover, complete
Additional basket (without cover)
Additional cover (without adapters)
Holder for cover
Holder for indicator
Spore tester
41 72 800
97.00
97.00
97.00
97.00
80.00
60 53 842 21.00
60 51 770 468.00
58 77 274
58 77 266
40.00
35.00
60 51 754 398.00
60 51 796 198.00
60 51 739 477.00
60 51 747 218.00
60 51 788 27.00
60 51 820 107.00 excl. VAT
Pr. Gr.
97.00
97.00
97.00
97.00
97.00
97.00
97.00
97.00
97.00
97.00
97.00
97.00
97.00
97.00
97.00
97.00
97.00
97.00
97.00
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
94
94
92
94
94
94
94
94
94
94
94
A 08/2005 − Page 11 August
HYGIENE CENTER: repair-exchange
With effect from February 2006, we will discontinue the repair-exchange service for the
Hygiene Center:
HYGIENE CENTER 230 V, German
HYGIENE CENTER 230 V, English
HYGIENE CENTER 230 V, French
We will of course continue to provide individual repairs as well as spare parts for this product.
Rep.-REF. 51 75 505
Rep.-REF. 51 75 752
Rep.-REF. 51 75 760
A 08/2005 − Page 12 August
CAD/CAM
inLab marketing package now available
The new marketing package for inLab users offers dental laboratories a unique opportunity to professionalize their communication efforts aimed at dentists.
The marketing package (format: A5) consists of various brochures devoted to specific clinical indications, material data sheets, a corporate image brochure, as well as a presentation folder and a documentation CD.
Consisting of several pages in each case, the four illustrated ‘indication brochures’ discuss the possibilities for fabricating polymer anterior crowns monoblock anterior and premolar crowns, as well as crowns and bridges .
The three data sheets deal with
, all-ceramic inlays/onlays/veneers , fine-structured all-ceramic materials, InCeram framework ceramics and zirconium oxide framework ceramics respectively . The emphasis is on the specific advantages of these materials as well as information relating to bonding methods.
The package also includes a sample corporate image brochure, with the help of which the inLab user can create his own “business card” containing specific information about his laboratory (company logo, corporate philosophy, special skills, location, address, etc.).
The presentation folder contains detailed information about the aesthetics, biocompatibility and clinical reliability of all-ceramic restorations created with the help of the Sirona CAD/CAM system. The folder has transparent pockets for leaflets, brochures, etc. which the laboratory would like to pass on to the dentist.
The CD brings together all the component parts of the marketing package in an electronic form – in PDF format for viewing on the PC and in QuarkXPress format. The latter permits the laboratory to individualize the documents before passing them on to an external printing company. The CD also contains the program Acrobat Reader (necessary for viewing the PDF documents on a PC).
In addition, the CD includes three sample letters in Word format, which the laboratory can adapt and then send to selected dentists. The CD sleeve booklet presents detailed information about how to create individually tailored information material relating to the dental laboratory.
In future, a sample copy of the marketing package will be supplied together with each inLab system. The package will also be sent subsequently to existing inLab users.
A 08/2005 − Page 13 August
CEREC 3, CEREC Scan, inLab
New power supply for the milling unit
With effect from serial no. 15,500 the CEREC 3, CEREC be fitted with a new power supply. The new power supply will be included in the next issue of the spare parts list for CEREC 3, CEREC details are as follows:
Scan,
Scan and inLab milling units will
inLab and CEREC 3D. The ordering
Designation REF. EUR, excl. VAT Pr. Gr.
Power supply 60 50 012 420.00 29
If required, the latest version of the price list can be downloaded directly from the Sirona dealer log. The link is as follows: https://partner.sirona.com/d/ecomaXL/index.php?site=SIRONA_HB_dl_tu_cerec_cerec3
A 08/2005 − Page 14 August
Delivery times
Status: August 2005
To help you plan more effectively, we provide you with this list of delivery times, updated on a monthly basis. The quoted delivery times are calculated as from the receipt of your order at the Bensheim factory.
To avoid delays, please make sure that you submit all the required information when placing your orders.
Subsequent changes to orders can lead to corresponding shifts in the delivery times.
Please pass this information on to the persons responsible in your company.
Treatment centres
C2 + /C3 + /C4
M1 +
C8 +
ProFeel +
+ /C5 + weeks
4 weeks weeks
C chair
SIROLUX Fantastic light (all models)
Accessories for treatment centres
3
1−2
1−2 weeks weeks weeks
Handpieces (high-speed, straight, contra-angle)
T1 CLASSIC
T1 LINE
T1/T2/T3 high-speed handpieces
ProSmile Handy
SIROAIR L
SIRONiTi/SIRONiTi starter kits
2–4
2–4
2–4
2
2
2 weeks weeks weeks weeks weeks weeks
Sterilizers/care systems
DAC Universal – as from commencement of deliveries 2–3 weeks
SIROCLAVE B
SIROCLAVE VS
SIROCLAVE S
SIROMINI B
SIROSEAL
SIRODEM
2−4
2−3
2−3
2−3
1−3
1−3 weeks weeks weeks weeks weeks weeks
SIROCLEAN 2–3 weeks
X-ray
HELIODENT DS
HELIODENT Vario 3
ORTHOPHOS 3/Ceph
4
8 weeks weeks weeks
ORTHOPHOS Plus/Ceph
ORTHOPHOS XG 5 DS/Ceph (refer to certification)
ORTHOPHOS XG Plus DS/Ceph (basic and fully featured version)
SIDEXIS (wall box/X-ray box)
8
8
6
4 weeks weeks weeks weeks
SIDEXIS USB Box
IO sensors
Available only in selected markets:
ORTHOPHOS 3 DS
ORTHOPHOS Plus DS/Ceph
CAD/CAM
CEREC 3
CEREC Scan inLab inEos
4
4
8 weeks weeks weeks
8–10 weeks
3–5 weeks
3–5 weeks
3–5 weeks
8–10 weeks
The delivery times relate to the current standard colours (grey-white).
In the case of combined orders of equipment with different delivery times, you should be guided by the longest delivery time. Depending on the day-to-day situation, the delivery times may be shorter or longer.
The delivery date confirmed by us will apply. In urgent cases, please contact our Customer Service Centre.
A 08/2005 − Page 15 August
For further information, please contact our
Customer Service Centre:
Telephone:
•
+49 / 62 51 / 16-16 16
E-mail and fax:
•
Product services
E-mail: [email protected]
Fax: +49 / 62 51 / 16-18 18
•
Order services
E-mail: [email protected]
Fax: +49 / 62 51 / 16-17 17
A 08/2005 − Page 16 August
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project