AmpliTaq Gold
®
360 Master Mix
Protocol
AmpliTaq Gold
®
360 Master Mix
Protocol
© Copyright 2009, 2010 Applied Biosystems. All rights reserved.
For Research Use Only. Not for use in diagnostic procedures.
Information in this document is subject to change without notice. Applied Biosystems assumes no responsibility for any errors that may appear in this document.
APPLIED BIOSYSTEMS DISCLAIMS ALL WARRANTIES WITH RESPECT TO THIS DOCUMENT, EXPRESSED OR IMPLIED, IN-
CLUDING BUT NOT LIMITED TO THOSE OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL
APPLIED BIOSYSTEMS BE LIABLE, WHETHER IN CONTRACT, TORT, WARRANTY, OR UNDER ANY STATUTE OR ON ANY OTHER
BASIS FOR SPECIAL, INCIDENTAL, INDIRECT, PUNITIVE, MULTIPLE OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH OR
ARISING FROM THIS DOCUMENT, INCLUDING BUT NOT LIMITED TO THE USE THEREOF.
NOTICE TO PURCHASER: LIMITED LICENSE
Use of this product is covered by US patent claims and corresponding patent claims outside the US. The purchase of this product includes a limited, non-transferable immunity from suit under the foregoing patent claims for using only this amount of product for the purchaser’s own internal research.
No right under any other patent claim (such as the patented 5’ Nuclease Process claims) and no right to perform commercial services of any kind, including without limitation reporting the results of purchaser's activities for a fee or other commercial consideration, is conveyed expressly, by implication, or by estoppel. This product is for research use only. Diagnostic uses require a separate license from Roche. Further information on purchasing licenses may be obtained by contacting the Director of Licensing, Applied Biosystems, 850 Lincoln Centre Drive, Foster City, California 94404, USA.
TRADEMARKS:
Applied Biosystems, AB (Design), GeneAmp, and Primer Express are registered trademarks and MicroAmp, Veriti and VeriFlex are trademarks of Applied Biosystems Inc. or its subsidiaries in the US and/or certain other countries.
All other trademarks are the sole property of their respective owners.
AmpliTaq Gold is a registered trademarks of Roche Molecular Systems, Inc.
All other trademarks are the sole property of their respective owners.
Part Number 4398944 Rev. B
06/2010
Contents
Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Safety information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi
How to use this guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
360 Master Mix Protocol . . . . . . . . . . . . . . . 1
Perform PCR using AmpliTaq Gold
360 Master Mix . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Bibliography . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Documentation and Support . . . . . . . . . . . . . . . . . . . . . . . . . 35
AmpliTaq Gold
®
360 Master Mix Protocol iii
Contents
iv AmpliTaq Gold
®
360 Master Mix Protocol
Preface
This preface covers:
AmpliTaq Gold
®
360 Master Mix Protocol v
vi
Safety information
Safety information
Note:
instrument hazard, see the “Safety” Appendix for the complete alert on the chemical or instrument.
Safety alert words
Four safety alert words appear in Applied Biosystems user documentation at points in the document where you need to be aware of relevant hazards. Each alert word—
IMPORTANT, CAUTION, WARNING, DANGER
—implies a particular level of observation or action, as defined below:
IMPORTANT!
– Indicates information that is necessary for proper instrument operation, accurate chemistry kit use, or safe use of a chemical.
CAUTION!
– Indicates a potentially hazardous situation that, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices.
WARNING!
– Indicates a potentially hazardous situation that, if not avoided, could result in death or serious injury.
DANGER!
– Indicates an imminently hazardous situation that, if not avoided, will result in death or serious injury. This signal word is to be limited to the most extreme situations.
MSDSs
The MSDSs for any chemicals supplied by Applied Biosystems or Ambion are available to you free 24 hours a day. For instructions on obtaining MSDSs, see
“Obtaining MSDSs” on page 26 .
IMPORTANT!
For the MSDSs of chemicals not distributed by Applied Biosystems or Ambion, contact the chemical manufacturer.
AmpliTaq Gold
®
360 Master Mix Protocol
How to use this guide
Purpose of this guide
The
AmpliTaq Gold
®
360 Master Mix Protocol
provides all the information you need to perform PCR over a wide range of DNA templates, including some of the most challenging GC-rich sequences.
Audience
This guide is intended for biologists who have some experience performing PCR.
Assumptions
This guide assumes that your thermal cycler has been installed by an
Applied Biosystems technical representative.
Text conventions
This guide uses the following conventions:
•
Bold
text indicates user action. For example:
Type
0
, then press
Enter
for each of the remaining fields.
•
Italic
text indicates new or important words and is also used for emphasis.
For example:
Before analyzing,
always
prepare fresh matrix.
• A right arrow symbol ( ) separates successive commands you select from a drop-down or shortcut menu. For example:
Select
File Open Spot Set
.
Right-click the sample row, then select
View Filter View All Runs
.
User attention words
Two user attention words appear in Applied Biosystems user documentation. Each word implies a particular level of observation or action as described below:
Note:
– Provides information that may be of interest or help but is not critical to the use of the product.
IMPORTANT!
– Provides information that is necessary for proper instrument operation, accurate chemistry kit use, or safe use of a chemical.
AmpliTaq Gold
®
360 Master Mix Protocol vii
How to use this guide viii AmpliTaq Gold
®
360 Master Mix Protocol
AmpliTaq Gold
®
360 Master Mix
Protocol
This chapter covers:
Perform PCR using AmpliTaq Gold® 360 Master Mix . . . . . . . . . . . . . . . . . . . . . . 6
AmpliTaq Gold
®
360 Master Mix Protocol 1
2
AmpliTaq Gold
®
360 Master Mix Protocol
Product information
Purpose of the product
Use the AmpliTaq Gold
®
360 Master Mix Kit to amplify a wide range of DNA fragments with high specificity.
About AmpliTaq
Gold
®
360 Master
Mix
The AmpliTaq Gold
®
360 DNA Polymerase in the AmpliTaq Gold
®
360 Master Mix amplifies a wide range of DNA contexts.The AmpliTaq Gold
®
360 Master Mix contains AmpliTaq Gold
®
360 DNA Polymerase. Heat activates AmpliTaq Gold
®
360 DNA Polymerase, resulting in highly specific, robust PCR amplification. The ionic strength and the pH of AmpliTaq Gold
®
360 DNA Master Mix are optimized for use with the AmpliTaq Gold
®
360 DNA Polymerase enzyme.
About the 360 GC enhancer
The 360 GC Enhancer is used for difficult-to-amplify templates, especially for templates with high GC content. You can adjust the amount of 360 GC Enhancer to optimize the PCR reaction. Amplicons that generate nonspecific products may require small amounts of enhancer to improve specificity. Amplicons with high GCcontent require more enhancer.
About this protocol
This protocol provides:
• Procedures and guidelines on PCR using the AmpliTaq Gold
®
360 Master Mix
• Information on troubleshooting PCR results
• A list of equipment and materials required for using the AmpliTaq Gold
®
360
Master Mix
For more information, refer to the documents shipped with your Applied Biosystems
PCR System.
AmpliTaq Gold
®
360 Master Mix Protocol
Product information
Contents
AmpliTaq Gold
®
360 Master Mix contains:
• AmpliTaq Gold
®
360 Master Mix
• 360 GC Enhancer
Available kit packaging
AmpliTaq Gold
®
360 Master Mix is available in the following packaging:
Quantity
Part number
4398876 Reagents sufficient for 40 × 50-µL reactions:
• AmpliTaq Gold
®
360 Master Mix, 1 × 1.0 mL
• 360 GC Enhancer, 1 × 1.5 mL
Reagents sufficient for 200 × 50-µL reactions:
• AmpliTaq Gold
®
360 Master Mix, 1 × 5.0 mL
• 360 GC Enhancer, 1 × 1.5 mL
Reagents sufficient for 2000 × 50-µL reactions:
• AmpliTaq Gold
®
360 Master Mix, 1 × 50 mL
• 360 GC Enhancer, 1 × 10 mL
Reagents sufficient for 2000 × 50-µL reactions:
• AmpliTaq Gold
®
360 Master Mix, 10 × 5.0 mL
• 360 GC Enhancer, 10 × 1.5 mL
4398881
4398886
4398901
Storage
When you receive the AmpliTaq Gold
®
360 Master Mix, store at
−
15 to
−
25 °C. The
AmpliTaq Gold
®
360 Master Mix can be thawed
once
, then stored at 2 to 8 °C.
AmpliTaq Gold
®
360 Master Mix Protocol 3
4
AmpliTaq Gold
®
360 Master Mix Protocol
Workflow
The workflow for PCR using the AmpliTaq Gold
®
360 Master Mix :
Prepare the reaction mix
Prepare the reaction plate or tubes
384-well plate 96-well plate
Set up the run method
Load and run the plate or tubes
Analyze the results
AmpliTaq Gold
®
360 Master Mix Protocol
Before you perform PCR
Before you perform PCR
Prevent contamination
Review
“PCR good laboratory practices” on page 18 .
Select an instrument and reaction plate
You can perform PCR amplification with any of the instruments listed under
“Thermal cyclers” on page 14 . Use MicroAmp
™
Optical 96-Well Reaction Plates
(PN N8010560). Other recommended equipment and consumables are listed
.
Calculate the number of required reactions
Calculate the number of reactions to perform for each assay. In your calculations, include extra reactions (approximately one extra reaction for every 10 required reactions) to provide excess volume for the volume lost during reagent transfers. For example, for a 96-well plate, prepare enough volume for approximately 110 reactions.
Note:
You can run multiple PCRs on one reaction plate. Include controls for each run on the plate.
AmpliTaq Gold
®
360 Master Mix Protocol 5
6
AmpliTaq Gold
®
360 Master Mix Protocol
Perform PCR using AmpliTaq Gold
®
360 Master Mix
Prepare the reaction mix
CHEMICAL HAZARD. AmpliTaq Gold
®
Master Mix.
IMPORTANT!
Avoid generating bubbles when mixing the enzyme.
1. Thaw the primers, template, and (optional) 360 GC Enhancer, then vortex the reagents before use.
2. Mix AmpliTaq Gold
®
360 Master Mix by gently pipetting it up and down.
3. Combine the following components in an appropriate tube according to the volumes that are shown in Table 1 . Multiply the volume for one reaction component (Table 1) by the total number of reactions, then add that volume to the tube.
Table 1 PCR reaction mix
Component
Volume
Per
25-µL reaction
(µL)
Volume per
50-µL reaction
(µL)
Final concentration
PCR-grade water
(Optional) 360 GC
Enhancer
AmpliTaq Gold
®
360
Master Mix
Variable
0.5 to 5
12.5
‡
Variable
1 to 10
25
‡
—
N/A
1
✕
‡ For targets with 65 to 75% GC, start with 2.5 µL in a 25-µL reaction or 5.0 µL in a
50-µL reaction (10% (v/v) of the reaction). For targets with >75% GC, start with
5 µL in a 25-µL reaction or 10 µL in a 50-µL reaction (20% (v/v) of the reaction). In general, if increased specificity is required, add 0.5. to 1 µL 360 GC Enhancer per
25-µL reaction or add 1 to 2 µL 360 GC Enhancer per 50-µL reaction (2 to 5% (v/v) of the reaction).
4. Cap the tube.
5. Gently vortex the tube on a low setting for no more than 5 seconds to mix the components.
6. Centrifuge the tube briefly to spin down the contents and to eliminate air bubbles from the solution.
7. Dispense equal volumes of the PCR reaction mix to the reaction plate or into
PCR tubes (see Table 1 ).
8. Place the plate in a MicroAmp
™ a MicroAmp
™
Splash-Free 96-Well Base or place the tubes in
96-well Base. Keep the plate or tubes in their respective bases throughout the remainder of the protocol.
9. Seal the plate with MicroAmp
™
Clear Adhesive Film or cap the tubes with
MicroAmp
™
8-Cap Strips.
AmpliTaq Gold
®
360 Master Mix Protocol
Perform PCR using AmpliTaq Gold
®
360 Master Mix
Prepare the reaction plate or tubes
10. Centrifuge the plate or tubes to collect the liquid at the bottom of the wells.
1. Prepare primers and DNA to their appropriate working dilutions (see Table 2 ).
For multiple PCR assays, prepare a master mix of components.
2. With the plate or tubes in the appropriate base, remove the seal from the plate or open the tubes.
3. Add primers and DNA to the appropriate wells or tubes according to Table 2 .
Include the no-template controls.
Table 2 Primer and DNA mix for PCR reactions
Component
Volume per
25-µL reaction
(µL)
‡
Volume per
50-µL reaction
(µL)
Final concentration
Primer 1
Primer 2
DNA
Total PCR volume
0.5 to 2.5
1 to 5
0.5 to 2.5
1 to 5
Variable
#
Variable
#
25 50
0.2 to 1.0 µM
§
0.2 to 1.0 µM
§
<1 µg/reaction
‡‡
—
‡ If the DNA is difficult to amplify in a 25-µL reaction, performing the PCR in a 50-µL reaction may give better results.
§ Lowering the primer concentration reduces potential secondary products.
# For a no-template control, add an equivalent volume of water.
‡‡ Preferably >10
4
copies of template but <1 µg DNA/reaction
4. Seal the plate with MicroAmp
™
Clear Adhesive Film or cap the tubes with
MicroAmp
™
8-Cap Strips.
5. Centrifuge the plate or tubes to collect the liquid at the bottom of the wells or the tubes. Ensure that the wells are uniformly filled.
AmpliTaq Gold
®
360 Master Mix Protocol 7
AmpliTaq Gold
®
360 Master Mix Protocol
Set up the run method
Set the:
• Thermal cycling conditions (see
Table 3 Three-temperature thermal cycling on a Veriti
™
, GeneAmp
®
PCR System 9700, or 2720 Thermal Cycler
Stage Step Temp.
Time
Holding Activation of AmpliTaq
Gold
®
360 Master Mix
95 °C 5 to 10 min
‡
Cycling
(25 to
40 cycles)
Denature
Anneal
95 °C
Primer T m
#
72 °C
15 to 30 sec
30 sec
‡‡
§
Extend 60 sec/kb
Holding
Holding
Final Extension
Final hold
72 °C
4 °C
7 min
∞
‡ See
“Adjusting the hold period for activation”
in the
AmpliTaq Gold
®
360 Master Mix
Protocol
, Appendix B.
§ For amplicons that are >2 kb, denature for 15 seconds. For amplicons that are
≤
2 kb, denature for 30 seconds.
# Although any primer can be used with this product, Applied Biosystems recommends using primers with T m s >55 °C. Use the Primer T m
calculator on an Applied Biosystems thermal cycler, or go to
www.appliedbiosystems.com/support/techtools/calc
.
‡‡ Thirty seconds for denaturation and annealing is adequate when you use Veriti
™
GeneAmp
®
or
PCR System thermal cyclers that display a calculated sample temperature.
Some models of thermal cyclers may require longer times.
• Ramp speed or mode:
Standard
• Reaction volume (µL):
25
or
50
Load and run the plate or tubes
1. Remove the plate or PCR tubes from the base.
2. Use a MicroAmp
™
Optical Film Compression Pad when you use a MicroAmp
™
Clear Adhesive Film.
3. Load the reaction plate or tubes into a PCR instrument.
4. Start the run.
5. Unload the reaction plate or tubes after the run is complete.
6. Store the plate or tubes at 4 °C or at
−
15 to
−
25 °C for long-term storage.
For more information
Refer to the user guide or getting started guides for your PCR system for more information about setting up the experiment, using and maintaining the instrument, and performing instrument calibrations.
8 AmpliTaq Gold
®
360 Master Mix Protocol
Analyze the results
WARNING! CHEMICAL HAZARD. Ethidium bromide.
Analyze the results
Check the purity of the PCR product
Analyze the PCR amplification products by agarose gel electrophoresis.
IMPORTANT!
To prevent contamination, never bring amplified PCR products into the PCR setup area.
1. Obtain a 1% agarose gel with ethidium bromide stain. You can use a gel of up to
3% agarose with ethidium bromide stain. Set up the electrophoresis apparatus and running buffer according to the manufacturer’s instructions.
2. Add an aliquot of the PCR product to a well of a new plate or to an appropriate new tube. Add an appropriate volume of gel-loading buffer to the PCR-product aliquot. For example, add 1 µL of 10
✕
gel-loading buffer to a 9-µL aliquot of
PCR reaction.
3. Mix the PCR-product aliquot and buffer in the wells by pipetting up and down, or briefly vortex the samples in the tubes. Spin the plate or pulse-spin the tubes.
4. Dispense the entire volume of the buffer-PCR product aliquot from each well or tube into a well of the gel.
5. Into one well of the gel, load a DNA-ladder marker appropriate to the PCR product length.
6. Run the gel at the voltage or time appropriate to amplicon length and agarose percentage so that the samples run 1/3 to 1/2 the length of the gel. Do not run the dye off the gel.
7. Place the gel on a UV transilluminator. Verify that each lane with a
PCR-product aliquot contains one distinct band.
For more information
Refer to the getting started guides for your PCR system for more information about analyzing a PCR results.
AmpliTaq Gold
®
360 Master Mix Protocol
CONFIDENTIAL — For AB Internal Use Only. Do Not Distribute
9
AmpliTaq Gold
®
360 Master Mix Protocol
Troubleshooting
Observation Possible cause Recommended action
Nonspecific amplification with or without a product band
Carryover contamination
Denaturation temperature is too low or too high
Nonspecific priming
Primer design is not optimal
• Use the GeneAmp
®
PCR Carry-Over
Prevention Kit (PN N8080068).
• Dispose of reagents, make fresh reagents, then repeat the PCR.
• Use 1 to 2 µL of 360 GC Enhancer in a 50 µL reaction. Use the 360 GC
Enhancer only if there are nonspecific products or products with
≥
65% GC
(see
“Prepare the reaction mix” on page 6
).
Adjust the temperature in increments of
1 degree Celsius. If you have a Veriti
™ thermal cycler, adjust the VeriFlex
™
Block in increments of 1 degree Celsius for up to six different temperatures.
Increase the annealing temperature in increments of 1 to 2 degrees Celsius.
Review primer design and composition.
10 AmpliTaq Gold
®
360 Master Mix Protocol
Observation Possible cause Recommended action
Low levels of
PCR product or no product band visible
Product band is smeared
Template concentration is too low
Experimental sample DNA is damaged or degraded
Increase the sample concentration.
Add more DNA or use sample that has been processed to minimize shearing and nicking.
Denaturation time is too short or too long
Denaturation temperature is too low or too high
Adjust the time in increments of
5 seconds.
Adjust the temperature in increments of
1 degree Celsius. If you have a Veriti
™ thermal cycler, adjust the VeriFlex
™
Block in increments of 1 degree Celsius for up to six different temperatures.
Annealing/extension temperature is too high
Lower the temperature in increments of
2 degrees Celsius. If you have a Veriti
™ thermal cycler, adjust the VeriFlex
™
Block in increments of 2 degrees Celsius for up to six different temperatures.
Annealing/extension time is too short Increase the time in increments of
15 seconds.
Cycle number is too low Increase the cycle number in increments of three cycles.
Review primer design and composition.
Primer design is not optimal
Preincubation/activation time is not sufficient
Carryover contamination
Increase the pre-PCR heat step in increments of 1 minute, or use the “Time
Release” protocol (see “Adjusting the hold period for activation” on page 19
).
• Use the GeneAmp
®
PCR Carry-Over
Prevention Kit (PN N8080068).
• Dispose of reagents, make fresh reagents, then repeat the PCR.
Adjust the time in increments of
5 seconds.
Denaturation time is too short or too long
Denaturation temperature is too low
Annealing/extension time is too long
Increase the temperature in increments of 1 degree Celsius.
Shorten the time in increments of
15 seconds.
Cycle number is too high Shorten the cycle number in increments of 3 cycles.
Experimental sample DNA is degraded Test a new aliquot of sample.
Troubleshooting
AmpliTaq Gold
®
360 Master Mix Protocol 11
AmpliTaq Gold
®
360 Master Mix Protocol
12 AmpliTaq Gold
®
360 Master Mix Protocol
Appendix A
Ordering Information
This appendix covers:
Other equipment and consumables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
AmpliTaq Gold
®
360 Master Mix Protocol 13
Appendix A Ordering Information
Materials and equipment not included
In addition to the reagents supplied, the items listed in the following table are required:
Thermal cyclers
Item
‡
Applied Biosystems PN
Veriti™ 60-Well Thermal Cycler
Veriti
™
96-Well Fast Thermal
Cycler
Veriti
™
96-Well Thermal Cycler
Veriti
™
384-Well Thermal Cycler
2720 Thermal Cycler
Aluminum 96-Well GeneAmp
®
PCR System 9700, Sample Block
Module
Gold-plated 96-Well GeneAmp
®
PCR System 9700
‡ Only one thermal cycler or one PCR system is required.
4384638
4375305
4375786
4388444
4359659
4314445
4314878
Other equipment and consumables
14
MicroAmp
™
MicroAmp
MicroAmp
MicroAmp
MicroAmp dNTP Mix
MicroAmp
™
™
™
™
™
Item
Optical 96-Well Reaction Plates
Splash-Free 96-Well Base
8-Tube Strip, 0.2 mL
8-Cap Strip
96-well Base
96-Well Tray/Retainer Set, 10 sets
Nuclease-free water (not DEPC-treated), 500 mL
MicroAmp
MicroAmp
™
™
Clear Adhesive Film
Optical Film Compression Pad
Centrifuge with plate adapter
‡
.
Source
Applied Biosystems
(PN N8010560)
Applied Biosystems
4312063
Applied Biosystems
(PN N8010580)
Applied Biosystems
(PN N8010535)
Applied Biosystems
N8010531
Applied Biosystems
(PN N8080260)
Applied Biosystems
(PN 403081)
Applied Biosystems
(PN AM9930)
Applied Biosystems
(PN 4306311)
Applied Biosystems
(PN4312639
Major laboratory supplier (MLS)
§
AmpliTaq Gold
®
360 Master Mix Protocol
Materials and equipment not included
Item Source
Pre-cast agarose gels, 1% up to 3% with ethidium bromide stain
Agarose
Disposable gloves
Electrophoresis apparatus
Microcentrifuge
Pipettes, positive-displacement or airdisplacement
Pipette tips with filter plugs
Polypropylene tubes
TBE buffer
TE buffer
Vortex
Disposable gloves
Microcentrifuge
1.5-mL microcentrifuge tubes
Tris-EDTA (TE) buffer, pH 8.0
Vortexer
MLS
MLS
MLS
MLS
MLS
MLS
MLS
MLS
MLS
MLS
MLS
MLS
MLS
MLS
MLS
MLS
‡ See instrument manual for compatibility.
§ For the MSDS of any chemical not distributed by Applied Biosystems, contact the chemical manufacturer. Before handling any chemicals, refer to the MSDS provided by the manufacturer, and observe all relevant precautions.
For more product recommendations, visit the PCR technology page at:
www3.appliedbiosystems.com/applicationstechnologies/PCR/index.htm?newGl
obalNav=true
AmpliTaq Gold
®
360 Master Mix Protocol 15
Appendix A Ordering Information
16 AmpliTaq Gold
®
360 Master Mix Protocol
Appendix B
Guidelines for
Designing PCR Assays
This appendix covers:
AmpliTaq Gold
®
360 Master Mix Protocol 17
Appendix B Guidelines for Designing PCR Assays
PCR good laboratory practices
General PCR practices
When preparing samples for PCR amplification:
• Use a positive-displacement pipette or aerosol-resistant pipette tips.
• Follow proper pipette-operating techniques to prevent aerosols.
• Wear clean gloves and a clean lab coat (not previously worn while handling amplified PCR products or used during sample preparation).
• Change gloves whenever you suspect that they are contaminated.
• Maintain separate areas and dedicated equipment and supplies for:
– Sample preparation
– PCR setup
– PCR amplification
– Analysis of PCR products
• Never bring amplified PCR products into the PCR setup area.
• Open and close all sample tubes carefully. Try not to splash or spray PCR samples.
• Keep reactions and components capped as much as possible.
• Clean lab benches and equipment periodically with 10% bleach solution. Use
DNA
Zap
™
Solution (PN AM9890).
18 AmpliTaq Gold
®
360 Master Mix Protocol
Select the amplicon site
Select the amplicon site
Using Primer Express
®
Software, select an
amplicon site
within the target sequence
(refer to the
Primer Express
®
Version 3.0 Getting Started Guide
and
Software Help
).
Guidelines
• Design primer pairs according to Primer Express Software guidelines.
• Use a primer pair that is specific to the target gene and does not amplify pseudogenes or other related genes.
• Test the primer pairs, then select the primer pair that produces the largest amount of specific product and the least amount of non-specific product. To determine specific product, compare migration through an agarose gel of amplicons to that of the DNA bands of known length in a DNA ladder.
Adjust thermal cycling
Adjusting the hold period for activation
For general PCR runs, Applied Biosystems recommends a pre-PCR activation setup of 95 °C for 10 minutes. Perform a titration of pre-PCR activation times (2 to 10 minutes in 1-minute intervals) to find the best enzyme activity for your reaction. You can also activate AmpliTaq Gold
®
360 DNA Polymerase to release active enzyme slowly over time (time release). Time release allows enzyme activity to increase with cycle number as the amount of template increases. This type of PCR can be accomplished
• With limited activation during the pre-PCR hold period
or
• Without activation during the pre-PCR hold period
In a “time-release” protocol, the enzyme is released slowly so that the enzyme concentration matches the template concentration, thereby increasing enzyme specificity. When no or limited (1-to-2 minute) pre-PCR activation is used, the enzyme is released gradually during the denaturation step (95 °C for 15 to 30 seconds) of each cycle. Because the enzyme is released slowly, up to 5 additional cycles may be required.
Limiting the amount of active enzyme at the beginning of the amplification reaction enhances specificity in the early PCR cycles.
Adjusting denaturation conditions
• In the early cycles, make sure that your DNA template is completely denatured.
• Do not exceed a denaturation temperature of 95 to 96 °C (Gelfand and White,
1990).
• A denaturation period of 30 seconds is adequate when using Veriti
GeneAmp
®
™
and
PCR System thermal cyclers with a calculated in-tube temperature.
Some models of thermal cyclers may require longer denaturation times.
Adjusting annealing conditions
• For increased product specificity, use annealing temperatures higher than 45 °C
(Saiki, Gelfand, and Stoffel, 1988; Rychlik, Spencer, and Rhoads, 1990).
AmpliTaq Gold
®
360 Master Mix Protocol 19
Appendix B Guidelines for Designing PCR Assays
Adjusting extension conditions
• Determine the optimum annealing temperature by testing at increments of 5 or fewer degrees Celsius until the maximum specificity is reached.
• Computer programs that calculate primer melting temperatures (T m
) can help you narrow the range of annealing temperatures to test. For such a T m
calculator, go to
http://www.appliedbiosystems.com
, then select
Services & Support
Technical Tools T
m
Calculator
. The GeneAmp
Thermal Cycler also contains a T m
calculator.
®
PCR System 9700
• Thirty seconds is adequate annealing time when using the Veriti
™
and
GeneAmp PCR System thermal cyclers with a calculated in-tube temperature.
Some models of thermal cyclers may require longer annealing times.
• The length of the target sequence affects the required extension time. Longer targets require increased extension times. In general, allow an extension time of approximately 60 seconds per 1000 bases at 72 °C.
• As the amount of DNA increases, the number of DNA polymerase molecules may become limiting. Compensate for this limitation by increasing the extension time in later cycles.
20 AmpliTaq Gold
®
360 Master Mix Protocol
Optimize the PCR conditions
Optimize the PCR conditions
Optimizing template concentration
• The DNA segment to be amplified from the template can be up to 4 kb long
(Jeffreys
et al
., 1988), although 100 to 1000 bases are more typical and easier to amplify.
• Start with enough copies of the template to obtain a signal after 25 to 30 cycles.
More than 10
4
copies but less than 1 µg of human genomic DNA per 50-µL reaction is the recommended range.
• If the target DNA concentration is low, you may need more than 35 cycles to produce sufficient product for analysis. As few as 1 to 10 target copies can be amplified (Saiki, Gelfand, Stoffel, 1988; Chou
et al
., 1992). Validation for lowcopy-number amplifications is best done for an average of 5 to 10 target molecules per sample to avoid statistical false negatives.
Optimizing enhancer concentration
The 360 GC Enhancer helps amplify amplicons that are difficult to amplify, including amplicons that are GC-rich or have GC-repeats or that generate nonspecific products.
In a 50-µL reaction, for targets with:
• 65 to 75% GC, start with 5 µL.
• >75% GC, start with 10 µL.
In general, if increased specificity is required, add 1 to 2 µL per 50-µL reaction.
The 360 GC Enhancer can reduce nonspecific amplification and improve the yield of specific products. However, excessive use of the 360 GC Enhancer can reduce yield, particularly for non-GC-rich amplicons.
AmpliTaq Gold
®
360 Master Mix Protocol 21
Appendix B Guidelines for Designing PCR Assays
22 AmpliTaq Gold
®
360 Master Mix Protocol
Appendix C
Safety
This appendix covers:
AmpliTaq Gold
®
360 Master Mix Protocol 23
Appendix C Safety
Chemical hazard warnings
WARNING!
CHEMICAL HAZARD.
Before handling any chemicals, refer to the Material Safety Data Sheet (MSDS) provided by the manufacturer, and observe all relevant precautions.
WARNING!
CHEMICAL HAZARD.
All chemicals in the instrument, including liquid in the lines, are potentially hazardous. Always determine what chemicals have been used in the instrument before changing reagents or instrument components. Wear appropriate eyewear, protective clothing, and gloves when working on the instrument.
WARNING!
CHEMICAL HAZARD.
Four-liter reagent and waste bottles can crack and leak. Each 4-liter bottle should be secured in a low-density polyethylene safety container with the cover fastened and the handles locked in the upright position. Wear appropriate eyewear, clothing, and gloves when handling reagent and waste bottles.
WARNING!
CHEMICAL STORAGE HAZARD.
Never collect or store waste in a glass container because of the risk of breaking or shattering.
Reagent and waste bottles can crack and leak. Each waste bottle should be secured in a low-density polyethylene safety container with the cover fastened and the handles locked in the upright position. Wear appropriate eyewear, clothing, and gloves when handling reagent and waste bottles.
24 AmpliTaq Gold
®
360 Master Mix Protocol
Chemical safety guidelines
Chemical safety guidelines
To minimize the hazards of chemicals:
• Read and understand the Material Safety Data Sheets (MSDSs) provided by the chemical manufacturer before you store, handle, or work with any chemicals or
hazardous materials. (See “About MSDSs” on page 26 .)
• Minimize contact with chemicals. Wear appropriate personal protective equipment when handling chemicals (for example, safety glasses, gloves, or protective clothing). For additional safety guidelines, consult the MSDS.
• Minimize the inhalation of chemicals. Do not leave chemical containers open.
Use only with adequate ventilation (for example, fume hood). For additional safety guidelines, consult the MSDS.
• Check regularly for chemical leaks or spills. If a leak or spill occurs, follow the manufacturer’s cleanup procedures as recommended in the MSDS.
• Comply with all local, state/provincial, or national laws and regulations related to chemical storage, handling, and disposal.
AmpliTaq Gold
®
360 Master Mix Protocol 25
Appendix C Safety
MSDSs
About MSDSs
Chemical manufacturers supply current Material Safety Data Sheets (MSDSs) with shipments of hazardous chemicals to new customers. They also provide MSDSs with the first shipment of a hazardous chemical to a customer after an MSDS has been updated. MSDSs provide the safety information you need to store, handle, transport, and dispose of the chemicals safely.
Each time you receive a new MSDS packaged with a hazardous chemical, be sure to replace the appropriate MSDS in your files.
Obtaining
MSDSs
The MSDS for any chemical supplied by Applied Biosystems is available to you free
24 hours a day. To obtain MSDSs:
1. Go to
www.appliedbiosystems.com
, click
Support
, then select
MSDS
.
2. In the Keyword Search field, enter the chemical name, product name, MSDS part number, or other information that appears in the MSDS of interest. Select the language of your choice, then click
Search
.
3. Find the document of interest, right-click the document title, then select any of the following:
•
Open
– To view the document
•
Print Target
– To print the document
•
Save Target As
– To download a PDF version of the document to a destination that you choose
Note:
For the MSDSs of chemicals not distributed by Applied Biosystems, contact the chemical manufacturer.
Chemical waste hazards
CAUTION!
HAZARDOUS WASTE.
Refer to Material Safety Data Sheets and local regulations for handling and disposal.
WARNING!
CHEMICAL WASTE HAZARD.
Wastes produced by Applied
Biosystems instruments are potentially hazardous and can cause injury, illness, or death.
WARNING!
CHEMICAL STORAGE HAZARD.
Never collect or store waste in a glass container because of the risk of breaking or shattering.
Reagent and waste bottles can crack and leak. Each waste bottle should be secured in a low-density polyethylene safety container with the cover fastened and the handles locked in the upright position. Wear appropriate eyewear, clothing, and gloves when handling reagent and waste bottles.
26 AmpliTaq Gold
®
360 Master Mix Protocol
Chemical waste safety guidelines
Chemical waste safety guidelines
To minimize the hazards of chemical waste:
• Read and understand the Material Safety Data Sheets (MSDSs) provided by the manufacturers of the chemicals in the waste container before you store, handle, or dispose of chemical waste.
• Provide primary and secondary waste containers. (A primary waste container holds the immediate waste. A secondary container contains spills or leaks from the primary container. Both containers must be compatible with the waste material and meet federal, state, and local requirements for container storage.)
• Minimize contact with chemicals. Wear appropriate personal protective equipment when handling chemicals (for example, safety glasses, gloves, or protective clothing). For additional safety guidelines, consult the MSDS.
• Minimize the inhalation of chemicals. Do not leave chemical containers open.
Use only with adequate ventilation (for example, fume hood). For additional safety guidelines, consult the MSDS.
• Handle chemical wastes in a fume hood.
• After emptying a waste container, seal it with the cap provided.
• Dispose of the contents of the waste tray and waste bottle in accordance with good laboratory practices and local, state/provincial, or national environmental and health regulations.
Waste disposal
If potentially hazardous waste is generated when you operate the instrument, you must:
• Characterize (by analysis if necessary) the waste generated by the particular applications, reagents, and substrates used in your laboratory.
• Ensure the health and safety of all personnel in your laboratory.
• Ensure that the instrument waste is stored, transferred, transported, and disposed of according to all local, state/provincial, and/or national regulations.
IMPORTANT!
Radioactive or biohazardous materials may require special handling, and disposal limitations may apply.
AmpliTaq Gold
®
360 Master Mix Protocol 27
Appendix C Safety
Biological hazard safety
General biohazard warning
WARNING!
BIOHAZARD.
Biological samples such as tissues, body fluids, infectious agents, and blood of humans and other animals have the potential to transmit infectious diseases. Follow all applicable local, state/provincial, and/or national regulations. Wear appropriate protective equipment, which includes but is not limited to: protective eyewear, face shield, clothing/lab coat, and gloves. All work should be conducted in properly equipped facilities using the appropriate safety equipment (for example, physical containment devices).
Individuals should be trained according to applicable regulatory and company/institution requirements before working with potentially infectious materials. Read and follow the applicable guidelines and/or regulatory requirements in the following:
• U.S. Department of Health and Human Services guidelines published in
Biosafety in Microbiological and Biomedical Laboratories
(stock no. 017-040-
00547-4;
bmbl.od.nih.gov
)
• Occupational Safety and Health Standards, Bloodborne Pathogens (29
CFR§1910.1030;
www.access.gpo.gov/ nara/cfr/waisidx_01/29cfr1910a_01.html
).
• Your company’s/institution’s Biosafety Program protocols for working with/handling potentially infectious materials.
Additional information about biohazard guidelines is available at:
www.cdc.gov
28 AmpliTaq Gold
®
360 Master Mix Protocol
Chemical alerts
Chemical alerts
General alerts for all chemicals
May cause eye, skin, and respiratory tract irritation. Read the MSDS, and follow the handling instructions. Wear appropriate protective eyewear, clothing, and gloves.
Specific chemical alerts
CHEMICAL HAZARD. AmpliTaq Gold® 360 Master Mix.
WARNING! CHEMICAL HAZARD. Ethidium bromide
causes eye, skin, and respiratory tract irritation and is a known mutagen (that is, it can change genetic material in a living cell and has the potential to cause cancer).
AmpliTaq Gold
®
360 Master Mix Protocol 29
Appendix C Safety
30 AmpliTaq Gold
®
360 Master Mix Protocol
Bibliography
Birch, D. E., Kolomodin, L., Laird, W. J., McKinney, N., Wong, J., Young, K. K. Y.,
Zangenberg, G. A., and Zoccoli, M. A. 1996. Simplified Hot Start PCR. Product review in
Nature
381: 445-446.
Bost, D. A., Zalloua, P., and Abramson, R. D. 1997. AmpliTaq Gold: Biochemical
Characterization and PCR Optimization. The FASEB Journal. 11: A1370.
Chou, Q., Russell, M., Birch, D.E., Raymond, J., and Bloch, W. 1992. Prevention of pre-PCR mis-priming and primer dimerization improves low- copy-number amplifications. Nucleic Acids Res. 20:1717–1723.
Eckert, K.A. and Kunkel, T.A. 1992. The fidelity of DNA polymerases used in the polymerase chain reactions. In: PCR: A Practical Approach. McPherson, M.J.,
Quirke, P., and Taylor, G.R., eds. New York: Oxford University Press. 225–244.
Faloona, F., Weiss, S., Ferre, F., and Mullis, K. 1990. Direct detection of HIV sequences in blood high-gain polymerase chain reaction [abstract]. In: 6th
International Conference on AIDS, University of California, San Francisco: San
Francisco (CA). Abstract 1019.
Gelfand, D.H. and White, T.J. 1990. Thermostable DNA polymerases. In: PCR
Protocols: A Guide to Methods and Applications. Innis, M.A., Gelfand, D.H.,
Sninsky, J.J., and White, T.J., eds. San Diego: Academic Press. 129–141.
Holland, P.M., Abramson, R.D., Watson, R., and Gelfand, D.H. 1991. Detection of specific polymerase chain reaction product by utilizing the 5´ 3´ exonuclease activity of Thermus aquaticus DNA polymerase. Proc. Natl. Acad. Sci. USA
88:7276–7280.
Innis, M.A., Myambo, K.B., Gelfand, D.H., and Brow, M.A. 1988. DNA sequencing with Thermus aquaticus DNA polymerase and direct sequencing of polymerase chain reaction-amplified DNA. Proc. Natl. Acad. Sci. USA 85:9436–9440.
Jeffreys, A.J., Wilson, V., Neumann, R., and Keyte, J., 1988. Amplification of human minisatellites by the polymerase chain reaction: towards DNA fingerprinting of single cells. Nucleic Acids Res. 16:10953-10971.
Kwok, S. and Higuchi, R. 1989. Avoiding false positives with PCR. Nature
339:237–238.
Kwok, S. 1990. Procedures to minimize PCR-product carry-over. In: PCR Protocols:
A Guide to Methods and Applications. Innis, M.A., Gefland, D.H., Sninsky, J.J., and
White, T.J., eds. San Diego: Academic Press. 142–145.
Mullis, K.B. and Faloona, F.A., 1987. Specific synthesis of DNA in vitro via a polymerase-catalyzed chain reaction.
Methods in Enzymology
155:335–350.
AmpliTaq Gold
®
360 Master Mix Protocol 31
Bibliography
Lawyer, F.C., Stoffel, S., Saiki, R.K., Myambo, K., Drummond, R., and Gelfand,
D.H. 1989. Isolation, characterization, and expression in E. coli of the DNA polymerase gene from the extreme thermophile, Thermus aquaticus, J. Biol. Chem.
264:6427-6437.
Richardson, C.C. 1966. DNA polymerase from Escherichia coli. In: Procedures in
Nucleic Acid Research. Cantoni, G.L. and Davies, D.R., eds. New York: Harper &
Row. 263–276.
Rychlik, W., Spencer, W.J., and Rhoads, R.E. 1990. Optimization of the annealing temperature for DNA amplification in vitro [published erratum appears in Nucleic
Acids Res 1991 Feb 11;19(3):698]. Nucleic Acids Res. 18:6409–6412.
Saiki, R.K., Gelfand, D.H., Stoffel, S., etþal. 1988. Primer-directed enzymatic amplification of DNA with a thermostable DNA polymerase. Science 239:487–491.
Saiki, R.K., Scharf, S.J.,
et al.,
1985. Enzymatic amplification of
β
-globin genomic sequences and restriction site analysis for diagnosis of sickle cell anemia.
Science
230:1350–1354.
32 AmpliTaq Gold
®
360 Master Mix Protocol
Glossary
amplicon biological replicates cycling stage diluent forward primer holding stage melting temperature (T m mode negative control
(NC)
)
A segment of DNA amplified during PCR.
Reactions that contain identical components and volumes, but evaluate separate samples of the same biological source (for example, multiple samples of the same liver tissue).
See also
.
In the thermal profile, a stage that is repeated. A cycling stage is also called an amplification stage.
A reagent used to dilute a sample or standard before it is added to the PCR reaction.
The diluent can be buffer or water.
Oligonucleotide that flanks the 5
′
end of the amplicon. The reverse primer and the forward primer are used together in PCR reactions to amplify the target.
In the thermal profile, a stage that can include one or more steps. You can add a holding stage to the thermal profile to activate enzymes, to inactivate enzymes, or to incubate a reaction.
In melt-curve experiments, the temperature at which 50% of the DNA is doublestranded and 50% of the DNA is dissociated into single-stranded DNA. The T m
is displayed in the melt curve.
The task for targets in wells that contain water or buffer instead of sample. No amplification of the target should occur in negative control wells. Also called no template control (NTC).
See
no-template control (NTC) quantity ramp
In quantitation experiments, the amount of target in the samples. Absolute quantity can refer to copy number, mass, molarity, or viral load. Relative quantity refers to the fold-difference between normalized quantity of target in the sample and normalized quantity of target in the reference sample.
The rate at which the temperature changes during the instrument run. The ramp is defined as a percentage. The ramp for the melt curve step is defined as a temperature increment. In the graphical view of the thermal profile, the ramp is indicated by a diagonal line.
AmpliTaq Gold
®
360 Master Mix Protocol 33
Glossary
ramp speed reaction mix
Speed at which the temperature ramp occurs during the instrument run. For optimal results using the AmpliTaq Gold
®
360 Master Mix , Applied Biosystems recommends using the standard ramp speed.
A solution that contains all components to run the PCR reaction, except for the template (sample, standard, or control).
A set of identical reactions in an experiment.
replicate group replicates reverse primer reverse transcriptase
See
An oligonucleotide that flanks the 3
′
end of the amplicon. The reverse primer and the forward primer are used together in PCR reactions to amplify the target.
An enzyme that converts RNA to cDNA. Reverse transcriptase is added to the PCR reaction to perform 1-step RT-PCR.
Definition of the reaction volume and the thermal profile for the instrument run.
run method sample stage
The template that you are testing.
In the thermal profile, a group of one or more steps. In core PCR, there are two types of stages: holding stage (including pre-PCR read and post-PCR read) and cycling stage (also called amplification stage).
step
A component of the thermal profile. For each step in the thermal profile, you can set the ramp rate (ramp increment for melt-curve steps), hold temperature, and hold time
(duration).
The nucleic acid sequence that you want to amplify and detect.
target technical replicates
Identical reactions that contain identical components and volumes and that evaluate the same sample.
See also
.
thermal profile
Part of the run method that specifies the temperature, time, and ramp for all steps and stages of the PCR instrument run.
T m
See
.
34 AmpliTaq Gold
®
360 Master Mix Protocol
Documentation and Support
Related documentation
You can download the following documents and other product-support documents from:
http://docs.appliedbiosystems.com/search.taf
Document
AmpliTaq Gold
®
360 Master Mix
Product Insert
AmpliTaq Gold
®
360 Master Mix Quick
Reference Card
Applied Biosystems Veriti
™
Thermal
Cycler User Guide
GeneAmp
®
PCR System 9700 Base
Module User’s Manual
GeneAmp® PCR System 9700 96-
Well Sample Block Module
Part number
4398275
4398954
4375799
4303481
4316011
AmpliTaq Gold
®
360 Master Mix Protocol 35
Documentation and Support
How to obtain support
For the latest services and support information for all locations, go to
www.appliedbiosystems.com
, then click the link for
Support
.
At the Support page, you can:
• Access worldwide telephone and fax numbers to contact Applied Biosystems
Technical Support and Sales facilities.
• Search through frequently asked questions (FAQs)
• Submit a question directly to Technical Support
• Order Applied Biosystems user documents, MSDSs, certificates of analysis, and other related documents
• Download PDF documents
• Obtain information about customer training
• Download software updates and patches
Send us your comments
Applied Biosystems welcomes your comments and suggestions for improving its user documents. You can e-mail your comments to:
IMPORTANT!
The e-mail address above is for submitting comments and suggestions relating only to documentation. To order documents, download PDF files, or for help with a technical question, see
“How to obtain support” above.
36 AmpliTaq Gold
®
360 Master Mix Protocol
Worldwide Sales and Support
Applied Biosystems vast distribution and service network, composed of highly trained support and applications personnel, reaches 150 countries on six continents.
For sales office locations and technical support, please call our local office or refer to our
Web site at
www.appliedbiosystems.com
.
Applied Biosystems is committed to providing the world’s leading technology and information for life scientists.
Headquarters
850 Lincoln Centre Drive
Foster City, CA 94404 USA
Phone: +1 650.638.5800
Toll Free (In North America): +1 800.345.5224
Fax: +1 650.638.5884
0 6/2010
www.appliedbiosystems.com
Part Number 4398944 Rev. B
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 2 AmpliTaq Gold® 360 Master Mix
- 3 Copyright Page
- 4 Contents
- 6 Preface
- 7 Safety information
- 7 Safety alert words
- 7 MSDSs
- 8 How to use this guide
- 8 Purpose of this guide
- 8 Audience
- 8 Assumptions
- 8 Text conventions
- 8 User attention words
- 10 AmpliTaq Gold® 360 Master Mix Protocol
- 11 Product information
- 11 Purpose of the product
- 11 About AmpliTaq Gold® 360 Master Mix
- 11 About the 360 GC enhancer
- 11 About this protocol
- 12 Contents
- 12 Available kit packaging
- 12 Storage
- 13 Workflow
- 14 Before you perform PCR
- 14 Prevent contamination
- 14 Select an instrument and reaction plate
- 14 Calculate the number of required reactions
- 15 Perform PCR using AmpliTaq Gold® 360 Master Mix
- 15 Prepare the reaction mix
- 16 Prepare the reaction plate or tubes
- 17 Set up the run method
- 17 Load and run the plate or tubes
- 17 For more information
- 18 Analyze the results
- 18 Check the purity of the PCR product
- 18 For more information
- 19 Troubleshooting
- 22 Appendix A Ordering Information
- 23 Materials and equipment not included
- 23 Thermal cyclers
- 23 Other equipment and consumables
- 26 Appendix B Guidelines for Designing PCR Assays
- 27 PCR good laboratory practices
- 27 General PCR practices
- 28 Select the amplicon site
- 28 Guidelines
- 28 Adjust thermal cycling
- 28 Adjusting the hold period for activation
- 28 Adjusting denaturation conditions
- 28 Adjusting annealing conditions
- 29 Adjusting extension conditions
- 30 Optimize the PCR conditions
- 30 Optimizing template concentration
- 30 Optimizing enhancer concentration
- 32 Appendix C Safety
- 33 Chemical hazard warnings
- 34 Chemical safety guidelines
- 35 MSDSs
- 35 About MSDSs
- 35 Obtaining MSDSs
- 35 Chemical waste hazards
- 36 Chemical waste safety guidelines
- 36 Waste disposal
- 37 Biological hazard safety
- 37 General biohazard warning
- 38 Chemical alerts
- 38 General alerts for all chemicals
- 38 Specific chemical alerts
- 40 Bibliography
- 42 Glossary
- 44 Documentation and Support
- 44 Related documentation
- 45 How to obtain support
- 45 Send us your comments
- 47 Contact information