advertisement
Mania EFX Series
user manual
EFX500 EFX600
EFX700 EFX800
Dimensions
Measurements are expressed in millimeters.
EFX500
500
410
180
EFX600
500
230
180
410
EFX700 & EFX800
500
230
140
400
230
© 2006 Martin Professional A/S, Denmark. All rights reserved. No part of this manual may be reproduced, in any form or by any means, without permission in writing from Martin
Professional A/S. Information subject to change without notice. Martin Professional A/S and all affiliated companies disclaim liability for any injury, damage, direct or indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to use or reliance on the information contained in this manual.
P/N 35000178 Rev. D
Contents
Overview
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Introduction
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Safety information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Installation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
AC power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Physical installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Creating a data link for DMX and synchronized operation . . . . . 13
Gobo wheels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Operation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Getting started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Music trig, auto trig and DMX modes . . . . . . . . . . . . . . . . . . . . . 17
Synchronized music trig and auto trig operation . . . . . . . . . . . . 18
DMX controller operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Changing personality settings . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Inverting effects movement . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Error messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Restriking the discharge lamp . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Adjusting focus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Service and maintenance
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Lamp replacement and adjustment . . . . . . . . . . . . . . . . . . . . . . 28
Replacing the main fuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Firmware and hard boot uploads . . . . . . . . . . . . . . . . . . . . . . . . 32
Circuit board layouts
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Troubleshooting
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Control panel overview
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Mania EFX500 DMX protocol
. . . . . . . . . . . . . . . . . . . . . . . . . . 38
Mania EFX600 DMX protocol
. . . . . . . . . . . . . . . . . . . . . . . . . . 41
Mania EFX700 DMX protocol
. . . . . . . . . . . . . . . . . . . . . . . . . . 44
Mania EFX800 DMX protocol
. . . . . . . . . . . . . . . . . . . . . . . . . . 46
Mania EFX Series specifications
. . . . . . . . . . . . . . . . . . . . . . . 49
Overview
F
G
A
B
C
D
E
4
A: Power inlet
B: Voltage selector switch (EFX600, EFX700 &
EFX800: fitted to EU models only)
C: DMX in
D: DMX out
E: Display and control buttons
F: Safety cable attachment point
G: Power on/off switch
Mania EFX user manual
Introduction
Thank you for selecting a dynamic lighting fixture from the Martin Mania
EFX Series. This series consists of DJ lighting fixtures with a motorized rotating parabolic mirror dish and a motorized rotating gobo wheel (gobos are outlines or masks placed in a light beam). The fixtures project complex moving colored flower effects.
The EFX500 and EFX600 feature an additional mirror drum with motorized pan (swivel) and tilt (rotation) that further enhances beam dynamics. The EFX800 features an additional motorized tilting (rotating) color paddlewheel that further enhances beam dynamics and color.
All Mania EFX fixtures offer the following features:
• Stand-alone single fixture and synchronized (master/slave) operation in auto and music triggering modes
• Adjustable music triggering sensitivity
• DMX control with two DMX modes: DMX mode 2 gives extended functionality on additional channels
• Adjustable focus
The EFX500 uses a long-life 250 watt halogen lamp. All other Mania
EFX fixtures use a long-life 150 watt discharge lamp.
S a f e t y i n f o r m a t i o n
Warning!
This product is not for household use. It presents risks of lethal or severe injury due to fire and heat, electric shock, ultraviolet radiation, lamp explosion and falls.
This product presents risks of lethal or severe injury due to fire and heat, electric shock, ultraviolet radiation, lamp explosion, and falls. Read this
manual before installing or powering the fixture, follow the safety precautions listed below and observe all warnings in this manual and on the fixture. If you have any questions about how to operate the fixture safely, please contact your Martin dealer or call the Martin 24-hour service hotline.
P r o t e c t i n g y o u r s e l f a n d o t h e r s f r o m e l e c t r i c s h o c k
• Ensure that the fixture is electrically connected to ground (earth).
Introduction 5
• Check the fixture’s voltage setting switch (if fitted) and serial number label before applying power. Only use the fixture if the fixture’s voltage setting matches your local AC power voltage.
• Disconnect the fixture from AC power before removing or installing the lamp, fuse, or any part, and when not in use.
• Use only a source of AC power that complies with local building and electrical codes and has both overload and ground-fault (earth leakage) protection.
• Refer all service not described in this manual to a Martin service technician.
• Do not expose the fixture to rain or moisture.
• Do not operate the fixture if any covers or components are missing, damaged or deformed.
• Do not use the product if the power cable is damaged. Replace the cable with a Martin item only (available from your Martin dealer).
P r o t e c t i n g y o u r s e l f a n d o t h e r s f r o m b u r n s a n d f i r e
Warning!
Hot lamp. The exterior of the fixture can become hot. Allow to cool for at least 10 minutes before handling or opening.
• Surface temperature under steady state condition = 100°C (212° F).
• Do not operate the fixture if the ambient temperature (T a
) exceeds 40° C
(104° F).
• Never attempt to bypass the thermostatic switch or fuses. Always replace defective fuses with ones of the specified type and rating.
• See serial label for replacement fuse size and lamp type.
• Keep all combustible materials (for example fabric, wood, paper) at least 0.3 meters (4 inches) away from the fixture. Keep flammable materials well away from the fixture.
• Do not illuminate surfaces within 1 meter (3.3 feet) of the fixture.
• Provide a minimum clearance of 0.1 meters (4 inches) around fans and air vents and ensure that air flow through and around vents is free and unobstructed.
• Never place filters or other materials over the lens or in the optical path.
• Do not look directly into the light.
• Change the lamp immediately if it becomes damaged or thermally deformed.
• Do not operate the fixture if any optical components or shields are missing, damaged or deformed: an unshielded discharge lamp emits dangerous UV radiation that can cause burns and eye injuries.
• Do not modify the fixture or install other than genuine Martin parts.
6 Mania EFX user manual
P r e v e n t i n g i n j u r i e s d u e t o f a l l s
• When suspending the fixture above ground level, verify that the structure can hold at least 10 times the weight of all installed devices.
• Ensure that all external covers and rigging hardware are securely fastened and use an approved means of secondary attachment such as a safety cable.
• Block access below the work area and work from a stable platform whenever installing or removing the fixture.
D i s c h a r g e l a m p s a f e t y
• EFX600, EFX700 and EFX800 fixtures use a discharge lamp. If the quartz envelope of a discharge lamp is broken, the lamp releases a small quantity of mercury and other toxic gases. If a discharge lamp explodes in a confined area, ventilate thoroughly and evacuate if necessary. Wear non-porous safety gloves when handling a broken discharge lamp. Treat broken or used discharge lamps and used safety gloves as hazardous waste and send to a specialist for disposal.
U n p a c k i n g
Important!
Do not lift or carry a fixture by holding the motor housing (if fitted) on the front of the fixture. It is not designed for this purpose. You could injure yourself or others, and you could cause damage that is not covered by the product guarantee.
The packing material is carefully designed to protect the fixture during shipment - always use it to transport the fixture.
Mania EFX fixtures are supplied with the following items:
• 3-wire power cable(s) with IEC power input connector.
• 5m (16.4 ft.) DMX cable.
• Mounting plate (installed).
• EFX500 only: 250 watt halogen lamp (installed).
• EFX600, EFX700 and EFX800: 150 watt discharge lamp (this is supplied separately to avoid damage during shipping and must be
installed before use – see “Installing a discharge lamp” on page 30).
• EFX800 only: paddlewheel shield for use during transport (installed).
Introduction 7
R e m o v i n g p r o t e c t i v e p a c k a g i n g
Important!
The EFX500 and EFX600 mirror drum is secured with packaging and white plastic ties for shipment. Wearing gloves to avoid cutting yourself on the mirrors, cut and remove the plastic ties. Check that the drum can be swivelled through 180° and rotated through 360° before operating the fixture. If it cannot, you may have missed one of the plastic ties.
Remove the clear protective film from the mirror drum before operating the fixture.
The EFX800 is supplied with a protective shield installed over the paddlewheel for use when transporting the fixture. The shield is secured with one screw (arrowed in illustration). Before your operate the fixture, remove the screw, lift out the shield and store both items for future use.
8
Reinstall the protective shield each time the fixture is transported.
Mania EFX user manual
Installation
A C p o w e r
Warning!
Ensure that the fixture’s voltage setting matches your local AC power voltage before applying power.
For protection from fire and electric shock, the fixture must be grounded
(earthed). The power supply must have both overload and ground-fault
(earth fault) protection.
Check that power cables are undamaged and rated for the current requirements of all connected devices before use.
Important!
Do not connect the fixture to a dimmer system, as this may cause damage that is not covered by the product guarantee.
Warning!
Mania EFX500 power settings
All Mania EFX500 models must be set to 115 V, 60 Hz or 230 V, 50 Hz AC power using the red voltage selector switch on the connections panel.
• Set the switch so that 115 V is visible if you have110-120 V, 60 Hz AC power.
• Set the switch so that 230 V is visible if you have 220-240 V, 50 Hz AC power.
Mania EFX600, EFX700 & EFX800 power settings
• Mania EFX600, EFX700 and EFX800 EU models can be set to 230 or
240 V, 50 Hz AC power using the switch on the connections panel. Use the 230 V setting if you have 220-230 V power, and use the 240 V setting if you have 230-240 V.
• Mania EFX600, EFX700 and EFX800 US models do not have a voltage selector switch and are supplied set up for 110-120 V, 60 Hz AC power.
Do not operate the fixture if local AC power voltage is outside the range specified for the fixture.
Installation 9
P o w e r p l u g s
Mania EFX fixtures are supplied with power cables to match most local
power outlet sockets (see “Included items” on page 51), but if there is no
power plug that matches your socket type, install a suitable groundingtype (earthed) power plug on the power cable. Consult a qualified electrician if you have any doubts about proper installation.
Follow the power plug manufacturer’s instructions, connecting the appropriate wires to ground (earth), live, and neutral. The table below shows some common wire identification schemes.
Function
live neutral
Wire (EU)
brown blue ground (earth) yellow/green
Wire (US)
black white green
Marking
“L”
“N”
Screw color
yellow or brass silver green
Table 1: Cord cap wiring
P h y s i c a l i n s t a l l a t i o n
Each Mania EFX fixture must be either:
• fastened to an overhead structure by means of its mounting plate and a
Martin rigging clamp (available from your Martin dealer), or
• fastened to a surface by means of its mounting plate and suitable bolts.
Do not install the fixture by any other means, as this can cause the fixture to overheat.
Ensure that the mounting structure or surface and all fasteners used can support at least 10 times the weight of all installed fixtures, clamps, cables, auxiliary equipment, etc.
Ensure that the fixture is located:
• at least 1 meter (3.3 ft.) away from the surface to be illuminated,
• at least 0.1 meters (4 in.) from any combustible materials (wood, fabric, paper, etc.) and
• well away from any flammable materials.
Ensure that the clearance around the fan and air vents is at least 0.1 meters (4 in.) and that airflow is free and unobstructed.
Warning! Block access below the work area and work from a stable platform when installing or servicing the fixture.
10 Mania EFX user manual
Always use a secure means of secondary attachment that can hold at least 10 times the weight of the fixture, looping it
the mounting plate, as this will leave the fixture unsecured.
B e a m a n g l e s a n d f i x t u r e o r i e n t a t i o n
The fixtures in the Mania EFX series have different optical configurations.
Referring to the illustration below will help you decide how to orient your fixture.
EFX500, EFX600 EFX700 EFX800
S u r f a c e m o u n t i n g
To mount the fixture on a surface, you will need four grade 8.8 (minimum)
8mm diameter, 13mm head hex screwbolts (or similar type fasteners of the same grade and size) and an eyebolt for the safety cable.
Installing the mounting plate separately
Surface mounting is easiest if you detach the mounting plate from the fixture, bolt the mounting plate to the surface, and then reattach the fixture. If you choose this method, access for reattachment and adjustment can be easier if you remove the swivel locks and replace them with two M8 hexagonal lock nuts (P/N 08132701). Install an eyebolt and safety attachment once the fixture is mounted.
Installing the fixture and mounting plate as a unit
If you prefer to install the fixture and mounting plate without separating them:
1. Using the inside back cover of this manual as a guide, drill three holes in the positions marked A.
Installation 11
12
2. Screw three grade
8.8 (minimum)
8mm diameter,
13mm head hex screwbolts or bolts into the holes at A, but do not tighten them fully –allow enough clearance between the bolt head and surface for the 3mm thick mounting plate.
Ø8mm
A
A
3. Fold the mounting plate so that it lies flat against the back of the fixture and tighten the swivel locks. For easier access for adjustment, it is possible to remove the swivel locks and replace them with two M8 hexagonal lock nuts,
P/N 08132701).
4. Hold the fixture up to the surface so that the screwbolt heads pass through the centers of the keyholes A in the mounting plate, and slide the fixture to engage the screwbolt heads in the mounting plate.
5. Using one of the remaining holes in the mounting plate as a guide, mark a position for a fourth hole to accept a screwbolt that will lock the fixture in place.
6. Remove the fixture from the surface, drill the fourth hole and replace the fixture on the surface as described in point 4 above. Screw the fourth screwbolt through the mounting plate into the surface to lock the fixture in place, using a washer on the screwbolt if necessary.
7. Install an eyebolt and safety attachment once the fixture is mounted.
O v e r h e a d m o u n t i n g
To hang a fixture on an overhead structure:
1. If using a rigging clamp, ensure that the clamp is undamaged and can bear at least 10 times the fixture’s weight. Bolt the clamp securely to the fixture’s mounting plate with a grade 8.8 (minimum) M12 bolt and lock nut through one of the 13 mm holes provided, or as recommended by the clamp manufacturer. The clamp must be attached centrally in the mounting plate to distribute the load evenly.
Mania EFX user manual
2. Working from a stable platform, clamp or fasten the fixture to the structure.
3. Install a safety cable that can hold at least 10 times the weight of the fixture.
4. Loosen the swivel locks, tilt the fixture to the desired angle, and retighten.
Important!
Check to make sure that the EFX500 and EFX600 mirror drum cable does not rub on the mounting plate. If necessary, reverse the mounting plate (see illustration).
C r e a t i n g a d a t a l i n k f o r D M X a n d s y n c h r o n i z e d o p e r a t i o n
You need a serial data link to:
• run light shows on one or more fixtures using a DMX controller, or
• run synchronized light shows on two or more fixtures (master/slave operation).
Fixtures on a serial data link must be daisy-chained in one single line, maximum 500 meters (1640 ft.) long, with maximum 32 fixtures on the link. If you wish to exceed 32 fixtures or 500 meters, or to split the link into branches, use an optically isolated amplifier-splitter such as the Martin
RS-485 Opto-Splitter (P/N 90758060).
Reliable data connection requires suitable cable. Standard microphone cable cannot transmit DMX data reliably over long runs. For best results, use cable with at least one twisted pair specifically designed for RS-485 applications. Your Martin dealer can supply suitable high quality cable in various lengths.
C o n n e c t i n g t h e s e r i a l d a t a l i n k
The Mania EFX has XLR data connectors, wired with pin 1 to ground, pin
2 to signal - (cold), and pin 3 to signal + (hot). This is the standard configuration for DMX devices.
One or more adaptor cables may be required to connect a Mania EFX fixture to the controller and/or other types of fixture, because some devices may have 5-pin XLR connectors, and others may have reversed
Installation 13
14
signal polarity (pin 2 hot and pin 3 cold). Connector polarity is normally specified on the device or in the device’s user manual.
5-pin to 3-pin
Adaptor
Male Female
3
4
5
1
2
1
2
3
P/N 11820005
3-pin to 5-pin
Adaptor
Male Female
1
2
3
1
2
3
4
5
P/N 11820004
3-pin to 3-pin
Phase-Reversing
Adaptor
Male Female
1
2
3
1
2
3
P/N 11820006
Male
Termination Plug
Female DMX
Termination Plug
1
2
3
Male XLR
120 Ohm
P/N 91613017
DMX connectors and polarity
Female XLR
1
2
3
120 Ohm
P/N 91613018
To connect the data link:
1. Power all devices off.
2. If you intend to use a DMX controller, run a data cable from the DMX controller’s data output to the first fixture’s data IN socket. If the controller has a 5-pin output, use a 5-pin male to 3-pin female adaptor cable (P/N 11820005).
3. If you intend to run fixtures in master/slave operation, insert a female
DMX termination plug (P/N 91613018) in the first fixture’s data IN socket.
4. Plug a data cable into the OUT socket of the first fixture and the IN socket of the next one. Continue connecting up to 32 Mania EFXs output-to-input.
5. Terminate the link by inserting a male termination plug (P/N 91613017) into the data output of the last fixture. A termination plug is simply an
XLR connector with a 120 Ohm, 0.25 W resistor soldered across pins 2 and 3.
G o b o w h e e l s
All Mania EFX fixtures contain a gobo wheel. Note that it is the whole wheel, and not the individual gobos, that rotates. Rotating gobo image effects are created by the mirror dish.
• The EFX500 has 11 colored gobos plus blackout.
• The EFX600 has 12 colored gobos.
• The EFX700 has 12 colored gobos.
• The EFX800 has 12 gobos. Color is provided by the color paddlewheel.
Mania EFX user manual
The Mania EFX500 contains the gobo wheel shown below.
12
11
1
10 2
9
3
8
4
7
5
6
EFX500 Gobo wheel
The Mania EFX600 contains the gobo wheel shown below.
12
11
1
10
2
9
3
8
4
7
5
6
EFX600 Gobo wheel
Installation 15
16
The Mania EFX700 contains the gobo wheel shown below.
12
11 1
10
2
9
3
8
4
7
5
6
EFX700 Gobo wheel
The Mania EFX800 contains the gobo wheel shown below.
12
11
1
10 2
9 3
8
4
7
5
6
EFX800 Gobo wheel
Mania EFX user manual
Operation
G e t t i n g s t a r t e d
Mania EFX fixtures are supplied in DMX mode with DMX address set to 1.
If you want to operate a fixture without a DMX controller, you need to set it
to music trig or auto trig mode before use (see “Selecting DMX, music trig
or auto trig operating modes” on page 18).
P o w e r i n g o n
Once the fixture is correctly and safely installed, power on at the fixture’s power on/off switch. The fixture will start up and reset.
If the fixture resets successfully, the software version installed will appear in the fixture’s display. For example, if software version 1.00 is installed, the message
100
should appear in the display.
Once the fixture has reset, the fixture will display either its DMX address,
901
(music trig mode) or
900
(auto trig mode).
If any other message is displayed, the fixture has detected an error (see
“Error messages” on page 25). If this occurs, switch off, wait a few
seconds and switch on again. If the error message appears again, consult your Martin dealer.
M u s i c t r i g , a u t o t r i g a n d D M X m o d e s
Mania EFX fixtures have three main operating modes:
Music trig mode: In this mode, lighting effects are triggered by music intensity. Multiple fixtures can be synchronized if one master fixture is set to music trig mode and the other fixtures are set to DMX mode.
Auto trig mode: In this mode, the fixture runs a factory-set dynamic light show that uses all the fixture’s effects in a random program. Multiple fixtures can be synchronized if one master fixture is set to auto trig mode and the other fixtures are set to DMX mode.
Operation 17
DMX mode: In DMX mode, fixtures receive control instructions via the serial data link. They will respond to control signals from a DMX controller
(or from another fixture set as master).
S e l e c t i n g D M X , m u s i c t r i g o r a u t o t r i g o p e r a t i n g m o d e s
Fixtures are supplied set to DMX mode with DMX address set to 1. If you intend to operate the fixture without a DMX controller, you need to set the fixture to music trig or auto trig mode.
To switch between DMX, auto trig and music trig modes:
1. Apply power to the fixture and wait while it resets. If the fixture is in DMX mode, the display will show the fixture’s DMX address.
2. Press the [Mode] button once. The fixture enters auto trig mode and
900 appears in the display.
3. Press the [Mode] button again once.
The fixture enters music trig mode, and
901
appears in the display.
4. Press the [Mode] button again once to return to DMX mode. The fixture’s
DMX address appears in the display.
DMX Address
X100 X10 X1 Mode
[Mode] button
The fixture will return to the mode you have set when it is powered off and on.
If you set the fixture to music trig mode but it does not respond satisfactorily to the music beat, adjust the music trig sensitivity level (see
“Adjusting music trig sensitivity” on page 23).
S y n c h r o n i z e d m u s i c t r i g a n d a u t o t r i g o p e r a t i o n
You can set multiple fixtures on a serial data link to respond together to a music trig or auto trig signal from one fixture. This feature allows synchronized operation without a DMX controller. The fixture sending the signal is the ‘master’ fixture and the fixtures that receive the signal are the
‘slave’ fixtures.
Important!
Set only one fixture as master: damage can occur if two masters, or a master and a DMX controller, are linked.
18 Mania EFX user manual
S e t t i n g u p s y n c h r o n i z e d o p e r a t i o n
To set up fixtures for synchronized operation:
1. Ensure that all fixtures on the data link are in DMX mode.
2. Select one fixture to be the master and set it to auto trig or music trig
mode (see “Selecting DMX, music trig or auto trig operating modes” on page 18)
3. When a slave fixture receives signals from the master, it will automatically begin operating in slave mode.
910
will appear in its display and the green Data LED will light to show that the fixture is receiving control data.
Slave mode
DMX Address
Data LED lit
X100 X10 X1 Mode
[Mode] button
Fixtures return to their DMX/auto trig/music trig settings when powered off and on, so you should only need to set fixtures as masters/slaves once.
D M X c o n t r o l l e r o p e r a t i o n
S e t t i n g D M X m o d e 1 o r 2
Two DMX modes are available: DMX mode 1 (normal) and DMX mode 2
(extended). Mode 2 uses two extra DMX channels that allow you to select pre-programmed macros and set the speed of effects movement from the
DMX controller. The fixture is supplied set to DMX mode 2.
• The EFX500 uses seven DMX channels in DMX mode 1 and nine channels in DMX mode 2.
• The EFX600 uses six DMX channels in DMX mode 1 and eight channels in DMX mode 2.
• The EFX700 uses four channels in DMX mode 1 and six channels in
DMX mode 2.
Operation 19
20
• The EFX800 uses five DMX channels in DMX mode 1 and seven channels in DMX mode 2
To toggle between DMX modes 1 and 2:
1. Apply power to the fixture and wait for the fixture to reset.
2. Hold the [Mode] button pressed in for 5 seconds to enter the fixture control menu.
3. Press the [X100] button repeatedly until
0
appears in the left of the display.
Press the [X1] button to toggle between
1
(to set DMX mode 1) and
2
(to set
DMX mode 2) in the right of the display.
DMX Address
X100 X10
4. Press the [Mode] button again to save your setting.
X1 Mode
DMX mode 2
S e t t i n g D M X a d d r e s s e s
If you intend to use a DMX controller, you will need to set the DMX address for each fixture. The DMX address, also known as the start channel, is the first channel used to receive instructions from the controller. It is set using the three addressing buttons on the fixture’s control panel.
For individual control, each fixture must be assigned its own DMX address and control channels. Control channels must not overlap with those of other fixtures. Fixtures of the same type with the same DMX address will receive the same instructions and behave identically.
As an example, a Mania EFX500 set to DMX mode 2 will use 9 channels.
If you give it DMX address 100, it will use channels 100, 101, 102, 103,
104, 105, 106, 107 and 108. Channel 109 is available for the next fixture.
The default factory-set DMX address is ‘1’. To set a fixture’s DMX address:
1. Decide on suitable DMX addresses for all the fixtures on the data link (note that 512 channels are available in one DMX universe).
2. Apply power to the fixture and wait while it resets.
DMX Address
X100 X10 X1 Mo
DMX addressing buttons
Mania EFX user manual
3. Use the three addressing buttons on the fixture’s control panel to enter the DMX address. The [X1] button increases the last digit in the DMX address, the [X10] button increases the address by 10 and the [X100] button increases the address by 100.
Fixtures remember their DMX address when they are powered off and on.
D M X c o n t r o l o p t i o n s
See also the DMX protocols starting on page 38 for an overview of DMX
commands and channels.
Control options
In DMX modes 1 and 2, the following functions can be controlled on all
models:
Strobe effect: A strobe effect with variable flash rate can be selected.
Auto trig: While in DMX mode, the Mania EFX can be remotely set to auto trig.
Reset:
All effects can be reset to their index positions from the controller using channel 1. The reset command must be sent for 5 seconds before it takes effect.
When a fixture is reset via DMX,
800
should appear in the digital display.
Dimming: The Mania EFX500 can be dimmed from 0% (blackout) up to
100% intensity using channel 2. All other Mania EFX fixtures can be dimmed from 0% to 100% using the shutter on channel 1.
Gobo wheel position, rotation and music trig: The gobo wheel can be positioned to project one of the gobos (or at blackout on the EFX500).
The gobo wheel can also be spun in either direction or set to music trig, in which gobos change with the music beat.
Mirror dish rotation and music trig: The mirror dish can be spun in either direction for dynamic projection effects or set to music trig.
In DMX mode 2, the following additional functions can be controlled on two extra channels:
Macros: On the first extra channel, you can select one of twelve factoryset macros. Macros are pre-programmed dynamic shows that use all the fixture’s effects.
Effect speed: On the second extra channel, you can either select the speed at which effects change or select tracking. Selecting a speed allows you to adjust fade times when using DMX controllers that do not
Operation 21
22
feature fade time programming (a fade time is the time taken for effects to change from one scene to the next). If you select tracking, the DMX controller defines fade times.
EFX500 and EFX600 models only
Pan: The mirror drum pans (swivels) approx. 180°. A pan position can be selected, pan can be set to narrow or wide shake, or pan can be set to music trig.
Tilt: The mirror drum tilts (rotates) 360°. The drum can be held in a stationary position, set to rotate in either direction, set to narrow or wide shake, or set to music trig.
EFX800 models only
Tilt: The color paddlewheel tilts (rotates) 360°. The paddlewheel can be held in a stationary position, set to rotate in either direction, set to narrow or wide shake, or set to music trig.
U n s u r e a b o u t s p e e d a n d t r a c k i n g ?
Set the fixture to tracking if you are using programmed fade times or macros on your DMX controller. Select an effects speed if you are not using programmed fade times or macros on your DMX controller.
However, if you are using fade times on your controller and have set the fixture to tracking, but effects movement is rough and irregular, setting fade times on your controller to zero and selecting an effects speed may give smoother movement.
Effects movement is set to ‘tracking’ if the fixture is in DMX mode 1 and by default.
D M X s i g n a l i n d i c a t o r
When a Mania EFX fixture receives a valid DMX signal, the green Data LED will light to show that the fixture is receiving control data.
DMX signal received
DMX Address
Data LED lit
X100 X10
Mania EFX user manual
X1 Mode
C h a n g i n g p e r s o n a l i t y s e t t i n g s
You can change certain personality settings using the buttons on the control panel:
• on all models, you can adjust music trig sensitivity
• on the EFX500 and EFX600, you can invert mirror drum rotation
• on the EFX800, you can invert color paddlewheel rotation
To change these personality settings:
• Hold the [Mode] button pressed in for 5 seconds to access the control menu.
• Use the [X100] button to select the personality feature.
• Use the [X1] button to change the setting for that feature.
Personality feature
DMX Address
Setting
X100 X10 X1 Mode
A d j u s t i n g m u s i c t r i g s e n s i t i v i t y
The music trig sensitivity can be adjusted on all models for optimum synchronization with the music. To adjust sensitivity:
1. With the fixture powered on and in music trig mode, play a typical music track at typical volume for your location.
2. Hold the [Mode] button on the control panel pressed in for 5 seconds to enter the control menu.
DMX Address
3. Press the [X100] button repeatedly until
3
appears on the left of the display.
X100 X10 X1 Mode
4. Press the [X1] button to select a music trig sensitivity setting on the right of the display from
1
(minimum sensitivity) to
9
(maximum sensitivity). The default setting is
6
.
5. Press the [Mode] button again to save your setting and exit the control menu.
Operation 23
24
I n v e r t i n g e f f e c t s m o v e m e n t
You can create symmetrical action across multiple EFX500, EFX600 and
EFX800 fixtures in synchronized and DMX operation by inverting the effects movement on some fixtures so that they ‘mirror’ the action of others. When one fixture tilts left, for example, a fixture on the other side of the dance floor can bet set to tilt right.
Inverting tilt on the EFX500, EFX600 and EFX800
To invert tilt (mirror drum rotation on the EFX500 and EFX600, color paddlewheel rotation on the EFX800):
1. Power the fixture on.
2. Hold the [Mode] button on the control panel pressed in for 5 seconds to enter the control menu.
3. Press the [X100] button repeatedly until
2
appears on the left of the display.
4. Press the [X1] button to change the tilt setting on the right of the display from
0
(normal tilt) to
1
(inverted tilt).
5. Press the [Mode] button again to save your setting and exit the control menu.
DMX Address
X100 X10 X1 Mode
Inverting pan on the EFX500 and EFX600
To invert pan (mirror drum swivel) on EFX500 and EFX600 fixtures:
1. Power the fixture on.
2. Hold the [Mode] button on the control panel pressed in for 5 seconds to enter the control menu.
3. Press the [X100] button repeatedly until
1
appears on the left of the display.
4. Press the [X1] button to change the pan setting on the right of the display from
0
(normal pan) to
1
(inverted pan).
5. Press the [Mode] button again to save your setting and exit the control menu.
DMX Address
X100 X10 X1 Mode
Mania EFX user manual
E r r o r m e s s a g e s
In the event of an error, the following messages appear in the fixture display:
701
Gobo wheel error (all fixtures). There is a problem with the gobo wheel positioning system.
702
Hot restrike protection (EFX600, EFX700 and EFX800). You have tried to restrike a lamp by DMX within 8 minutes of extinguishing the lamp via DMX.
703
Color paddlewheel error (EFX800). There is a problem with the color paddlewheel positioning system.
If an error message is displayed, try powering the fixture off and then on again to reset it. If the problem persists, contact your Martin dealer.
R e s t r i k i n g t h e d i s c h a r g e l a m p
If the discharge lamp in the EFX600, EFX700 and EFX800 is powered off via DMX during operation, you must wait eight minutes before the lamp can be restruck.
If you try to strike the lamp anyway, the message
702
will appear in the display.
Operation 25
A d j u s t i n g f o c u s
Focus can be adjusted from approx. 2 meters (6.6 ft.) to approx. 20 meters (66 ft.) using the focus adjustment knob.
On EFX500 and EFX600 fixtures, the focus adjustment knob is close to the lens aperture in the mirror drum cutout.
EFX500, EFX600
On EFX700 and EFX800 fixtures, the focus adjustment knob is close to the beam aperture on the front plate.
EFX700, EFX800
26 Mania EFX user manual
Service and maintenance
Mania EFX fixtures require simple routine maintenance. The maintenance schedule depends heavily on the operating environment. Please consult a
Martin service technician for recommendations.
Refer any service procedure not described here to a qualified technician.
Warning! Disconnect the fixture from power and allow it to cool for at least 10 minutes before removing any cover.
C l e a n i n g
Important! Excessive dust, grease, and smoke fluid buildup degrades performance and causes overheating and damage to the fixture that is not covered by the warranty. Check and, if necessary, clean fixtures at regular intervals.
C l e a n i n g t h e f a n a n d a i r v e n t s
To maintain adequate cooling, dust must be cleaned from the fan and air vents periodically.
1. Disconnect the fixture from power and allow it to cool for at least 10 minutes.
2. Loosen the lamp cover release thumbscrew and slide and lift the lamp cover out of the fixture housing. Let the cover hang on its safety strap.
3. Remove the four torx screws holding the main cover (see illustration on right) and slide and lift the cover out of the housing. Let the cover hang on its safety strap.
4. Remove dust and dirt from the fan blades and vent grills using a soft brush, cotton swab, vacuum, or compressed air.
5. Reinstall the main cover and lamp cover securely before reapplying power.
Service and maintenance 27
C l e a n i n g o p t i c a l c o m p o n e n t s
Use care when cleaning optical components. The coated surfaces are fragile and even small scratches may be visible in the fixture’s light output.
EFX500
EFX600
EFX800
EFX600
EFX700
EFX800
1. Disconnect the fixture from power and allow it to cool for at least 10 minutes.
2. Open the covers as
described in “Cleaning the fan and air vents”
above.
EFX500
3. Blow or vacuum away loose dust. Remove dirt from lenses, gobos and mirror wheel with a soft cloth or cotton swabs
Optical path
wetted with isopropyl alcohol. Regular glass cleaner may also be used, but no residues may remain. To avoid scratches, do not rub. Instead, press repeatedly to lift dirt off surfaces.
4. Any remaining residues or streaking can be removed with distilled water. Mixing the water with a small amount of wetting agent such as
Kodak Photoflo will help prevent streaking and spotting.
5. Dry with a clean, soft, lint-free cloth or compressed air.
6. Reinstall all covers before reapplying power.
L a m p r e p l a c e m e n t a n d a d j u s t m e n t
Warning! Wear safety glasses and gloves and allow the fixture to cool for at least 10 minutes before replacing the lamp.
28
H a l o g e n l a m p ( M a n i a E F X 5 0 0 )
The Mania EFX500 uses a 250 watt halogen lamp. Replace the lamp when it reaches the average life specified by the manufacturer. The halogen lamp has an integral reflector and does not require adjustment when correctly installed.
Mania EFX user manual
Important!
Use only this type of lamp. See “Accessories” on page 52 for
details of replacement lamps. Installing any other lamp may damage the fixture.
Installing a halogen lamp
1. Disconnect the fixture from power and allow it to cool for at least 10 minutes.
2. Loosen the lamp cover release thumbscrew enough to slide and lift the lamp cover out of the fixture housing. The lamp cover is attached to the housing with a safety strap.
3. If replacing an old lamp, remove it together with its ceramic socket from the lampholder clip and, being careful not to strain any wires, gently pull the lamp off the socket.
4. Hold the new lamp by its base (do not touch any other part of the lamp). Push the lamp pins squarely into the ceramic socket.
5. If you touched the bulb, the reflector or any optical components, clean them with a clean, soft, lint-free cloth wetted with isopropyl alcohol and dry with a clean, soft, lint-free cloth or compressed air.
6. Replace the lamp and socket in the lampholder clip, ensuring that the reflector sits flat against its plate and is held securely in place. When installed correctly, the rim of the reflector locates under the heads of two stop screws so that the reflector is held firmly between these screws and the lampholder clip.
7. Close the lamp cover, checking that no wires are trapped, and retighten the thumbscrew.
D i s c h a r g e l a m p ( E F X 6 0 0 , E F X 7 0 0 & E F X 8 0 0 )
The Mania EFX600, EFX700 and EFX800 use a 150 watt long-life discharge lamp.
For optimum lamp life, always allow discharge lamps to warm up for at least 5 minutes before dousing.
Service and maintenance 29
Restriking a discharge lamp
Note that, when a discharge lamp is powered off, it must be allowed to cool for 8 minutes before it is restruck.
Installing a discharge lamp
Warning! Wear safety glasses and gloves and allow the fixture to cool for at least 10 minutes before replacing the lamp.
1. Disconnect the fixture from power and allow it to cool for at least 10 minutes.
2. Loosen the screw holding the lamp cover
(see illustration on right: EFX600 illustrated) and open the cover. The cover is attached to the housing with a safety strap.
3. Loosen the four small screws (see illustration on right) holding the lampholder and pull the lampholder gently out of the fixture. Note which edge faces outwards, as the lampholder must be reinstalled in the same position.
Lamp adjustment
Lamp adjustment
Lamp adjustment
This edge faces out
30
4. If replacing an old lamp, remove it from its ceramic socket.
5. Hold the new lamp by its base (do not touch any other part of the lamp). Push the lamp pins squarely into the socket.
6. If you touched the bulb, the reflector or any optical components, clean them with a clean, soft, lint-free cloth wetted with isopropyl alcohol and dry with a clean, soft, lint-free cloth or compressed air.
Mania EFX user manual
7. Replace the lampholder in the housing, making sure that the edge with the semicircular cutout in its center faces out towards the edge of the and reinstall the four screws. Close the lamp cover, checking that no wires are trapped, and replace the lamp cover screw.
8. Reapply power.
Discharge lamp adjustment
The discharge lamp alignment can be adjusted to optimize the projected image using the adjustment screws on the lampholder (see illustration on right). Experiment with turning the screws until the brightest part of the beam is centered in the projected images.
Lamp adjustment
Lamp adjustment
Lamp adjustment
R e p l a c i n g t h e m a i n f u s e
Mania EFX fixtures use a slow-blow fuse for protection against current overload. An indication that the fuse may have blown is that when power is applied and the lamp is switched on, no light is produced.
If the fuse blows repeatedly, there is probably a fault. Disconnect the fixture from power and data and contact a Martin service technician.
Never bypass the fuse or replace it with one of another type or rating.
To replace the main fuse:
1. Disconnect the power cable.
2. Pry open the fuse holder next to the power cable inlet with a flat-head screwdriver and remove the fuse.
3. Replace the fuse with one of the same type and rating. Fuse ratings are listed on serial number labels
and under “Electrical” on page 50.
4. Replace the fuse holder before reapplying power.
Service and maintenance 31
F i r m w a r e a n d h a r d b o o t u p l o a d s
It is possible to upload new firmware to via the data IN connector using, for example, an uploader such as the Martin MP-2 Uploader, or a PC using a
Martin DABS interface device and suitable software. The latest firmware versions for Mania EFX fixtures can be downloaded from the Support area of the Martin website at http://www.martin.com
If a fixture will not accept normal firmware uploads, it can be forced to accept an upload by starting it in hard boot mode. To start in hard boot mode, hold both the [Mode] button and the [X100] button pressed in while powering on the fixture. When the fixture is in hard boot mode, the data
LED blinks.
If you are not sure how to carry out uploads, your Martin dealer will be able to give advice or carry out the upload for you.
32 Mania EFX user manual
Circuit board layouts
EFX500 Main PCB, all models
J11
J3
MCU
J13
J12
Tilt Pan
EFX600 Main PCB, all models
Display
J10
J8
J10
J8
J17
Hall sensor gobo
J12
DMX
J3
J7
Tilt
J6
Pan
J2
MCU
J4 J15
J13
J16
Shutter
Circuit board layouts 33
34
EFX700 Main PCB, all models
Display
J10
J8
J17
Hall sensor gobo
MCU
J12
DMX
J3
J7 J6 J2 J4
J13
J15 J16
Shutter
EFX800 Main PCB, all models
Display
MCU
J12
DMX
J3
J7 J6 J2
J13
J4
Gobo
J15 J16
Shutter
J10
J8
J17
Hall
Sensor
Paddle
Wheel
Hall sensor gobo
Mania EFX user manual
EFX500 Power PCB, all models
Lamp
J6
J5 J3
J1
C1
J13 J9
J8
J7
Fan
EFX600, EFX700 and EFX800 Power PCB
EU models
Fuse
US models
Fuse
J1
C1
J3
J2
Ballast J5
J1
J8
J7
J9
J6
Fan
Main PCB
J13
Main PCB
J12
Ballast
Capacitor
Transformer
J2
J5
C1
J3
J8
J7
J9
J6
Fan
Main PCB
J13
Main PCB
J12
Circuit board layouts 35
Troubleshooting
Problem
No light
No action in music trig mode
No action in music trig and auto trig modes
Unsatisfactory action in synchronized operation
Poor action in a new fixture
Fuse blows repeatedly
EFX600, EFX700, EFX800:
Impossible to restrike lamp after dousing via DMX.
Fixtures reset correctly but behave erratically or do not respond during DMX or synchronized operation
Possible cause(s)
Shutter closed (EFX600,
EFX700 & EFX800 using
DMX control)
No power to the fixture
Blown fuse
Burned out lamp
Fixture too hot
Sound too low to activate control circuit
Electrical malfunction
Fixtures incorrectly linked
More than one fixture set as master
Some transport packaging has not been removed
Electrical malfunction
8 minute hot restrike protection delay activated
Data link not terminated
Suggested remedy
Open shutter via DMX
Check connections
If power is applied and the lamp is switched on but does not light, check and replace fuse if necessary
Install new lamp
Allow to cool
Improve airflow around fixture
Adjust music level sensitivity
Increase music volume
Move fixture closer to music source
Refer to a Martin service technician
Check data link connections between fixtures
Check that all slave fixtures are set to DMX mode
Remove all plastic ties from mirror drum until drum rotates freely
Refer to a Martin service technician
Wait 8 minutes before restriking a hot discharge lamp
Insert DMX termination plug in output of last fixture on link. In synchronized operation, insert DMX termination plug in input of first fixture
36 Mania EFX user manual
Control panel overview
E F X 5 0 0 a n d E F X 6 0 0 c o n t r o l p a n e l s e t t i n g s
0
1
2
3
Personality feature
DMX mode
Pan (mirror drum swivel) invert
Tilt (mirror drum rotation) invert
Music trig sensitivity**
0
1
1
2
0
1
1
↓
9
Setting*
Mode 1 (normal)
Mode 2 (extended)
Pan normal
Pan inverted
Tilt normal
Tilt inverted
Minimum
↓
Maximum
E F X 7 0 0 c o n t r o l p a n e l s e t t i n g s
0
3
Personality feature
DMX mode
Music trig sensitivity**
1
2
1
↓
9
Setting*
Mode 1 (normal)
Mode 2 (extended)
Minimum
↓
Maximum
E F X 8 0 0 c o n t r o l p a n e l s e t t i n g s
0
2
3
Personality feature
DMX mode
Tilt (color paddlewheel rotation) invert
Music trig sensitivity**
0
1
1
2
1
↓
9
Setting*
Mode 1 (normal)
Mode 2 (extended)
Tilt normal
Tilt inverted
Minimum
↓
Maximum
* Default settings are shown in bold type.
** Music trig sensitivity is
6
by default.
Control panel overview 37
Mania EFX500 DMX protocol
Channel
1
2
3
Value
0 - 4
5 - 68
69 - 100
101 - 132
133 - 249
250 - 255
0 - 255
0 - 9
10 - 19
20 - 29
30 - 39
40 - 49
50 - 59
60 - 69
70 - 79
80 - 89
90 - 99
100 - 109
110 - 119
120 - 175
176 - 207
208 - 239
240 - 244
245 - 249
250 - 255
0 - 3
4 - 7
8 - 11
12 - 15
16 - 19
20 - 23
24 - 26
27 - 30
Percent Function
Strobe effect, auto trig, music trig, reset
No function 0 - 1
2 - 26
27 - 39
Strobe (fast to slow)
Remote stand-alone, auto trig
40 - 51
52 - 97
98 - 100
Remote stand-alone, music trig
Reserved, no function
Reset fixture (value must be held for 5 seconds)
Intensity
0 - 100 0 - 100%
Colored gobo wheel positions, gobo wheel rotation, gobo wheel music trig
Full gobo positions
Gobo 1
Gobo 2
Gobo 3
Gobo 4
31 - 35
36 - 38
39 - 42
43 - 46
47 - 68
Gobo 5
Gobo 6
Gobo 7
Gobo 8
Gobo 9
Gobo 10
Gobo 11
Gobo 12 (Blackout)
Reserved (Blackout, gobo 12)
69 - 81
82 - 93
94 - 95
96 - 97
98 - 100
Continuous Rotation
Clockwise (fast
→
slow)
Counterclockwise (slow
→
fast)
Music function
Gobo wheel music trig fast
Gobo wheel music trig slow
Gobo wheel music trig dynamic
38 Mania EFX user manual
Channel
4
5
Value
0 - 1
2 - 128
129 - 255
0 - 1
2 - 65
66 - 129
130 - 192
193 - 208
209 - 239
Percent Function
0
1 - 50
51 - 100
0
1 - 25
26 - 50
51 - 75
76 - 81
82 - 93
Colored gobo wheel shake
No function
Narrow shake (slow
→ fast)
Wide shake (slow
→
fast)
Mirror dish rotation, shake and music trig
Stop
Counterclockwise rotation (fast
→
slow)
Clockwise rotation (slow
→
fast)
Shake (slow
→
fast)
Random shake
Reserved, stop
6
7
240 - 244
245 - 249
250 - 255
0
63
127
128 - 182
183 - 239
240 - 244
245 - 249
250 - 255
0 - 1
2 - 63
64 - 65
66 - 127
128 - 129
130 - 184
185 - 239
240 - 244
245 - 249
250 - 255
94 - 95
96 - 97
98 - 100
0
24
50
51 - 71
72 - 93
94 - 95
96 - 97
98 - 100
0
1 - 24
25
26 - 49
50
51 - 72
73 - 93
94 - 95
96 - 97
98 - 100
Mirror dish music trig, fast
Mirror dish music trig, slow
Mirror dish music trig, dynamic
Pan (mirror drum swivel) position, shake and music trig
Maximum left pan
Neutral
Maximum right pan
Narrow shake (slow
→
fast)
Wide shake (slow
→
fast)
Music trig pan, fast
Music trig pan, slow
Music trig pan, dynamic
Tilt (mirror drum rotation) rotation, shake and music trig
No rotation
Clockwise rotation (slow
→
fast)
No rotation
Counterclockwise rotation (fast
→
slow)
No rotation
Narrow shake (slow
→
fast)
Wide shake (slow
→
fast)
Mirror drum rotation music trig, fast
Mirror drum rotation music trig, slow
Mirror drum rotation music trig, dynamic
Mania EFX500 DMX protocol 39
Channel
8*
Value
0 - 15
16 - 31
32 - 47
48 - 63
64 - 79
80 - 95
96 - 111
112 - 127
128 - 143
144 - 159
160 - 175
176 - 191
192 - 207
19 - 24
25 - 30
31 - 37
38 - 43
44 - 49
50 - 55
56 - 62
63 - 68
69 - 74
75 - 81
Percent Function
Macros (DMX mode 2 only)
No Macro 0 - 5
6 - 11
12 - 18
Macro 1
Macro 2
Macro 3
Macro 4
Macro 5
Macro 6
Macro 7
Macro 8
Macro 9
Macro 10
Macro 11
Macro 12
208 - 255 82 - 100 Reserved. No function
Effects speed (DMX mode 2 only)
9*
0 - 1
2 - 255
0
1 - 100
Tracking (default)
Fast
→
slow
*
Channels 8 and 9 are available in DMX mode 2 only. In DMX mode 1, effects speed is set to ‘tracking’.
40 Mania EFX user manual
Mania EFX600 DMX protocol
Channel
1
2
Value
0 - 4
5 - 122
123 - 129
130 - 189
190 - 199
200 - 209
210 - 219
220 - 239
240 - 249
250 - 255
0 - 9
10 - 19
20 - 29
30 - 39
40 - 49
50 - 59
60 - 69
70 - 79
80 - 89
90 - 99
100 - 109
110 - 119
120 - 175
176 - 207
208 - 239
240 - 244
245 - 249
250 - 255
0 - 3
4 - 7
8 - 11
12 - 15
16 - 19
20 - 23
24 - 26
27 - 30
31 - 35
36 - 38
39 - 42
43 - 46
47 - 68
Percent Function
Intensity, strobe effect, auto trig, reset, lamp off
Blackout (shutter closed) 0 - 1
2 - 47
48 - 50
Intensity 0-100%, lamp on
Shutter open
51 - 74
75 - 78
79 - 82
83 - 86
87 - 94
95 - 98
99 - 100
Strobe (fast to slow)
Shutter closed
Random strobe
Remote stand-alone, auto trig
Blackout (shutter closed)
Reset fixture (value must be held for 5 seconds)
Lamp off (value must be held for 5 seconds and channels
2 & 3 must be set to more than 252 / 99%). Note that there is an 8-minute delay before lamp can be restruck.
Colored gobo wheel position, rotation and music trig
Full gobo positions
Gobo 1
Gobo 2
Gobo 3
Gobo 4
Gobo 5
Gobo 6
Gobo 7
Gobo 8
Gobo 9
Gobo 10
Gobo 11
Gobo 12
Reserved (gobo 12)
69 - 81
82 - 93
94 - 95
96 - 97
98 - 100
Continuous Rotation
Clockwise (fast
→
slow)
Counterclockwise (slow
→
fast)
Music function
Gobo wheel music trig fast
Gobo wheel music trig slow
Gobo wheel music trig dynamic
Mania EFX600 DMX protocol 41
42
Channel
3
4
Value
0 - 1
2 - 128
129 - 255
0 - 1
2 - 65
66 - 129
130 - 192
193 - 208
209 - 239
Percent Function
0
1 - 50
51 - 100
0
1 - 25
26 - 50
51 - 75
76 - 81
82 - 93
Colored gobo wheel shake
No function
Narrow shake (slow
→ fast)
Wide shake (slow
→
fast)
Mirror dish rotation, shake and music trig
Stop
Counterclockwise rotation (fast
→
slow)
Clockwise rotation (slow
→
fast)
Shake (various shakes)
Random shake
Reserved, stop
5
6
240 - 244
245 - 249
250 - 255
0
63
127
128 - 182
183 - 239
240 - 244
245 - 249
250 - 255
0 - 1
2 - 63
64 - 65
66 - 127
128 - 129
130 - 184
185 - 239
240 - 244
245 - 249
250 - 255
94 - 95
96 - 97
98 - 100
0
24
50
51 - 71
72 - 93
94 - 95
96 - 97
98 - 100
0
1 - 24
25
26 - 49
50
51 - 72
73 - 93
94 - 95
96 - 97
98 - 100
Mirror dish music trig, fast
Mirror dish music trig, slow
Mirror dish music trig, dynamic
Pan (mirror drum swivel) position, shake and music trig
Maximum left pan
Neutral
Maximum right pan
Narrow shake (slow
→
fast)
Wide shake (slow
→
fast)
Music trig pan, fast
Music trig pan, slow
Music trig pan, dynamic
Tilt (mirror drum rotation) rotation, shake and music trig
No rotation
Clockwise rotation (slow
→
fast)
No rotation
Counterclockwise rotation (fast
→
slow)
No rotation
Narrow shake (slow
→
fast)
Wide shake (slow
→
fast)
Mirror drum rotation music trig, fast
Mirror drum rotation music trig, slow
Mirror drum rotation music trig, dynamic
Mania EFX user manual
Channel
7*
Value
0 - 15
16 - 31
32 - 47
48 - 63
64 - 79
80 - 95
96 - 111
112 - 127
128 - 143
144 - 159
160 - 175
176 - 191
192 - 207
19 - 24
25 - 30
31 - 37
38 - 43
44 - 49
50 - 55
56 - 62
63 - 68
69 - 74
75 - 81
Percent Function
Macros (DMX mode 2 only)
No Macro 0 - 5
6 - 11
12 - 18
Macro 1
Macro 2
Macro 3
Macro 4
Macro 5
Macro 6
Macro 7
Macro 8
Macro 9
Macro 10
Macro 11
Macro 12
208 - 255 82 - 100 Reserved. No function
Effects speed (DMX mode 2 only)
8*
0 - 1
2 - 255
0
1 - 100
Tracking (default)
Fast
→
slow
*
Channels 7 and 8 are available in DMX mode 2 only. In DMX mode 1, effects speed is set to ‘tracking’.
Mania EFX600 DMX protocol 43
Mania EFX700 DMX protocol
44
Channel
1
2
Value
0 - 4
5 - 122
123 - 129
130 - 189
190 - 199
200 - 209
210 - 219
220 - 239
240 - 249
250 - 255
0 - 9
10 - 19
20 - 29
30 - 39
40 - 49
50 - 59
60 - 69
70 - 79
80 - 89
90 - 99
100 - 109
110 - 119
120 - 175
176 - 207
208 - 239
240 - 244
245 - 249
250 - 255
0 - 3
4 - 7
8 - 11
12 - 15
16 - 19
20 - 23
24 - 26
27 - 30
31 - 35
36 - 38
39 - 42
43 - 46
47 - 68
Percent Function
Intensity, strobe effect, auto trig, reset, lamp off
Blackout (shutter closed) 0 - 1
2 - 47
48 - 50
Intensity 0-100%, lamp on
Shutter open
51 - 74
75 - 78
79 - 82
83 - 86
87 - 94
95 - 98
99 - 100
Strobe (fast to slow)
Shutter closed
Random strobe
Remote stand-alone, auto trig
Blackout (shutter closed)
Reset fixture (value must be held for 5 seconds)
Lamp off (value must be held for 5 seconds and channels
2 & 3 must be set to more than 252 / 99%). Note that there is an 8-minute delay before lamp can be restruck.
Colored gobo wheel position, rotation and music trig
Full gobo positions
Gobo 1
Gobo 2
Gobo 3
Gobo 4
Gobo 5
Gobo 6
Gobo 7
Gobo 8
Gobo 9
Gobo 10
Gobo 11
Gobo 12
Reserved (gobo 12)
69 - 81
82 - 93
94 - 95
96 - 97
98 - 100
Continuous Rotation
Clockwise (fast
→
slow)
Counterclockwise (slow
→
fast)
Music function
Gobo wheel music trig fast
Gobo wheel music trig slow
Gobo wheel music trig dynamic
Mania EFX user manual
Channel
3
4
Value
0 - 1
2 - 128
129 - 255
0 - 1
2 - 65
66 - 129
130 - 192
193 - 208
209 - 239
Percent Function
0
1 - 50
51 - 100
0
1 - 25
26 - 50
51 - 75
76 - 81
82 - 93
Colored gobo wheel shake
No function
Narrow shake (slow
→ fast)
Wide shake (slow
→
fast)
Mirror dish rotation, shake and music trig
Stop
Counterclockwise rotation (fast
→
slow)
Clockwise rotation (slow
→
fast)
Shake (various shakes)
Random shake
Reserved, stop
5*
240 - 244
245 - 249
250 - 255
0 - 15
16 - 31
32 - 47
48 - 63
64 - 79
80 - 95
96 - 111
112 - 127
128 - 143
144 - 159
160 - 175
176 - 191
192 - 207
208 - 255
94 - 95
96 - 97
98 - 100
0 - 5
6 - 11
12 - 18
19 - 24
25 - 30
31 - 37
38 - 43
44 - 49
50 - 55
56 - 62
63 - 68
69 - 74
75 - 81
82 - 100
Mirror dish music trig, fast
Mirror dish music trig, slow
Mirror dish music trig, dynamic
Macros (DMX mode 2 only)
No Macro
Macro 1
Macro 2
Macro 3
Macro 4
Macro 5
Macro 6
Macro 7
Macro 8
Macro 9
Macro 10
Macro 11
Macro 12
Reserved. No function
Effects speed (DMX mode 2 only)
6*
0 - 1
2 - 255
0
1 - 100
Tracking (default)
Fast
→
slow
*
Channels 5 and 6 are available in DMX mode 2 only. In DMX mode 1, effects speed is set to ‘tracking’.
Mania EFX700 DMX protocol 45
Mania EFX800 DMX protocol
46
Channel
1
2
Value
0 - 4
5 - 122
123 - 129
130 - 189
190 - 199
200 - 209
210 - 219
220 - 239
240 - 249
250 - 255
0 - 9
10 - 19
20 - 29
30 - 39
40 - 49
50 - 59
60 - 69
70 - 79
80 - 89
90 - 99
100 - 109
110 - 119
120 - 175
176 - 207
208 - 239
240 - 244
245 - 249
250 - 255
0 - 3
4 - 7
8 - 11
12 - 15
16 - 19
20 - 23
24 - 26
27 - 30
31 - 35
36 - 38
39 - 42
43 - 46
47 - 68
Percent Function
Intensity, strobe effect, auto trig, reset, lamp off
Blackout (shutter closed) 0 - 1
2 - 47
48 - 50
Intensity 0-100%, lamp on
Shutter open
51 - 74
75 - 78
79 - 82
83 - 86
87 - 94
95 - 98
99 - 100
Strobe (fast to slow)
Shutter closed
Random strobe
Remote stand-alone, auto trig
Blackout (shutter closed)
Reset fixture (value must be held for 5 seconds)
Lamp off (value must be held for 5 seconds and channels
2 & 3 must be set to more than 252 / 99%). Note that there is an 8-minute delay before lamp can be restruck.
Gobo wheel position, rotation and music trig
Full gobo positions
Gobo 1
Gobo 2
Gobo 3
Gobo 4
Gobo 5
Gobo 6
Gobo 7
Gobo 8
Gobo 9
Gobo 10
Gobo 11
Gobo 12
Reserved (gobo 12)
69 - 81
82 - 93
94 - 95
96 - 97
98 - 100
Continuous Rotation
Clockwise (fast
→
slow)
Counterclockwise (slow
→
fast)
Music function
Gobo wheel music trig fast
Gobo wheel music trig slow
Gobo wheel music trig dynamic
Mania EFX user manual
Channel
3
4
Value
0 - 1
2 - 128
129 - 255
0 - 1
2 - 65
66 - 129
130 - 192
193 - 208
209 - 239
Percent Function
0
1 - 50
51 - 100
0
1 - 25
26 - 50
51 - 75
76 - 81
82 - 93
Gobo wheel shake
No function
Narrow shake (slow
→ fast)
Wide shake (slow
→
fast)
Mirror dish rotation, shake and music trig
Stop
Counterclockwise rotation (fast
→
slow)
Clockwise rotation (slow
→
fast)
Shake (various shakes)
Random shake
Reserved, stop
5
240 - 244
245 - 249
250 - 255
0 - 3
4 - 103
104 - 105
106 - 155
156 - 157
158 - 207
208 - 209
210 - 224
225 - 239
240 - 244
245 - 249
250 - 255
94 - 95
96 - 97
98 - 100
0-1
2 - 40
40-41
42 - 59
60-61
62 - 80
81 - 82
83 - 87
88 - 93
94 - 95
96 - 97
98 - 100
Mirror dish music trig, fast
Mirror dish music trig, slow
Mirror dish music trig, dynamic
Color paddlewheel position, rotation, shake and music trig
No rotation
Fixed positions 0-360°
No rotation
Clockwise rotation (slow
→
fast)
No rotation
Counterclockwise rotation (fast
→
slow)
No rotation
Narrow shake (slow
→
fast)
Wide shake (slow
→
fast)
Music trig pan, fast
Music trig pan, slow
Music trig pan, dynamic
Mania EFX800 DMX protocol 47
Channel
6*
Value
0 - 15
16 - 31
32 - 47
48 - 63
64 - 79
80 - 95
96 - 111
112 - 127
128 - 143
144 - 159
160 - 175
176 - 191
192 - 207
19 - 24
25 - 30
31 - 37
38 - 43
44 - 49
50 - 55
56 - 62
63 - 68
69 - 74
75 - 81
Percent Function
Macros (DMX mode 2 only)
No Macro 0 - 5
6 - 11
12 - 18
Macro 1
Macro 2
Macro 3
Macro 4
Macro 5
Macro 6
Macro 7
Macro 8
Macro 9
Macro 10
Macro 11
Macro 12
208 - 255 82 - 100 Reserved. No function
Effects speed (DMX mode 2 only)
7*
0 - 1
2 - 255
0
1 - 100
Tracking (default)
Fast
→
slow
*
Channels 6 and 7 are available in DMX mode 2 only. In DMX mode 1, effects speed is set to ‘tracking’.
Mania EFX Series specifications
P h y s i c a l
Dimensions EFX500 & EFX600 (LxWXH) 410 x 500 x 230mm (16.2 x 19.7 x 9.1 in.)
Dimensions EFX700 & EFX800 (LxWXH) 400 x 500 x 230mm (15.8 x 19.7 x 9.1 in.)
EFX500 weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.5 kg (27.6 lb.)
EFX600 EU model weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 kg (31 lb.)
EFX600 US model weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16.5 kg (36.5 lb.)
EFX700 EU model weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14.1 kg (31.1 lb.)
EFX700 US model weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16.6 kg (36.6 lb.)
EFX800 EU model weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14.7 kg (32.4 lb.)
EFX800 US model weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.2 kg (38 lb.)
All dimensions and weights include the supplied mounting plate
I n s t a l l a t i o n
Orientation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . any
Minimum distance to combustible material . . . . . . . . . . . . . . . . . . . . . . . 0.1 m (4 in.)
Minimum distance to illuminated surface . . . . . . . . . . . . . . . . . . . . . . . 0.3 m (12 in.)
Minimum clearance around air vents . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.1 m (4in)
Suitable for mounting on combustible surfaces (wood, etc.) using mounting bracket and plate and respecting minimum distances specified
C o n s t r u c t i o n
Housing . . . . . . . . . . . . . . . . . . . . . . . . steel and aluminum, rubber corner protectors
L a m p
E F X 5 0 0 , a l l m o d e l s
Lamp type . . . . . . . . . . . . . . . . . . . .24 V, 250 W halogen lamp with integral reflector
Lamp socket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .GX5.3
E F X 6 0 0 , E F X 7 0 0 & E F X 8 0 0 , a l l m o d e l s
Lamp type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 W discharge lamp
Lamp socket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G12
C o n t r o l a n d p r o g r a m m i n g
Control options . . . . . . . . . . . DMX, stand-alone music trig & auto trig, master/slave
Individual effects can be set to music trig remotely via DMX
EFX500: number of DMX channels. . . . . . . . . . . . . . . . . . . 7 (mode 1) or 9 (mode 2)
EFX600: number of DMX channels. . . . . . . . . . . . . . . . . . . 6 (mode 1) or 8 (mode 2)
EFX700: number of DMX channels. . . . . . . . . . . . . . . . . . . 4 (mode 1) or 6 (mode 2)
EFX800: number of DMX channels. . . . . . . . . . . . . . . . . . . 5 (mode 1) or 7 (mode 2)
Data protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . USITT DMX-512 (1990)
D y n a m i c e f f e c t s
E F X 5 0 0 , a l l m o d e l s
Motorized rotating parabolic mirror dish
Motorized rotating gobo wheel, 11 colored gobos plus blackout
Motorized mirror drum, 180° swivel (pan) & 360° rotation (tilt)
0-100% dimmer
Strobe effect shutter
E F X 6 0 0 , a l l m o d e l s
Motorized rotating parabolic mirror dish
Motorized rotating gobo wheel, 12 colored gobos
Motorized mirror drum, 180° swivel (pan) & 360° rotation (tilt)
Electromechanical 0-100% dimmer
Strobe effect shutter
E F X 7 0 0 , a l l m o d e l s
Motorized rotating parabolic mirror dish
Motorized rotating gobo wheel, 12 colored gobos
Electromechanical 0-100% dimmer
Strobe effect shutter
E F X 8 0 0 , a l l m o d e l s
Motorized rotating parabolic mirror dish
Motorized rotating gobo wheel, 12 gobos
Motorized color paddlewheel, 360° rotation (tilt)
Electromechanical 0-100% dimmer
Strobe effect shutter
E l e c t r i c a l
E F X 5 0 0 , a l l m o d e l s
AC power . . switch-selectable, 110-120 VAC, 60 Hz / 220-240 VAC, 50 Hz nominal
Main fuse. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.15 AT
Typical power and current*
@ 110 V, 60 Hz. . . . . . . . . . . . . . . . . . . . . . . . . . . 229 W, 2.1 A, PF = 0.997
@ 115 V, 60 Hz. . . . . . . . . . . . . . . . . . . . . . . . . . . 248 W, 2.2 A, PF = 0.997
@ 120 V, 60 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . 264 W, 2.2 A, PF = 0.997
@ 220 V, 50 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . 229 W, 1.1 A, PF = 0.995
@ 230 V, 50 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . 247 W, 1.1 A, PF = 0.995
@ 240 V, 50 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . 265 W, 1.2 A, PF = 0.994
E F X 6 0 0 , E F X 7 0 0 & E F X 8 0 0 , E U m o d e l s
AC power . . . . . . . . . . . . . . . . switch-selectable, 220-230/240 VAC, 50 Hz nominal
Main fuse. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 AT
Typical power and current*
@ 220 V, 50 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . 181 W, 0.9 A, PF = 0.950
@ 230 V, 50 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . 197 W, 1.0 A, PF = 0.926
@ 240 V, 50 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . 204 W, 1.0 A, PF = 0.923
E F X 6 0 0 , E F X 7 0 0 & E F X 8 0 0 , U S m o d e l s
AC power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110-120 VAC, 60 Hz nominal
Main fuse. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.15 AT
Typical power and current*
@ 110 V, 60 Hz. . . . . . . . . . . . . . . . . . . . . . . . . . . 189 W, 1.8 A, PF = 0.963
@ 115 V, 60 Hz. . . . . . . . . . . . . . . . . . . . . . . . . . . 207 W, 1.9 A, PF = 0.964
@ 120 V, 60 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . 226 W, 2.0 A, PF = 0.957
* V = volts, Hz = hertz, W = watts, A = amps, PF = power factor
Allow for a deviation of +/- 10% from typical figures listed above.
Measurements made at nominal voltage. Local supply voltages can vary by +/-10%.
C o n n e c t i o n s
Power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-prong IEC male socket
Data in/out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-pin locking XLR)
T h e r m a l
Time required to cool before handling. . . . . . . . . . . . . . . . . . . . minimum 10 minutes
Maximum ambient temperature (T a
)
. . . . . . . . . . . . . . . . . . . . . . 40° C (104° F)
E F X 5 0 0 , a l l m o d e l s
Maximum surface temperature, steady state, T a
= 40° C . . . . . . . . . . 100°C (212°F)
E F X 6 0 0 , E F X 7 0 0 & E F X 8 0 0 , a l l m o d e l s
Maximum surface temperature, steady state, T a
= 40° C . . . . . . . . . . . 80°C (176°F)
A p p r o v a l s
EU EMC . . . . . . . . . . . . . . . . . EN 55015, EN 61547, EN 61000-3-3, EN 61000-3-2
EU safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EN 60598-1, EN 60598-2-17
US safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UL 1573
Canadian safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..CSA C22.2 NO 166
I n c l u d e d i t e m s
E F X 5 0 0 , a l l m o d e l s
Long-life 250 W halogen lamp
3 m (9.8 ft) EU mains cable 3x1.0mm
2
with Schuko male connector
3 m (9.8 ft) EU mains cable 3x1.0mm
2
with no male connector
2 m (6.5 ft) US mains cable 18AWG with US male connector (UL approved)
5 meter (16.4 ft.) RS-485 XLR cable for data link . . . . . . . . . . . . . . . . P/N 11820008
User manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 35000168
E F X 6 0 0 , E F X 7 0 0 & E F X 8 0 0 , E U m o d e l s
Long-life 150 W discharge lamp
3 m (9.8 ft) EU mains cable 3x1.0mm
2
with Schuko male connector
3 m (9.8 ft) EU mains cable 3x1.0mm
2
with no male connector
5 meter (16.4 ft.) RS-485 XLR cable for data link . . . . . . . . . . . . . . . . P/N 11820008
User manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 35000168
E F X 6 0 0 , E F X 7 0 0 & E F X 8 0 0 , U S m o d e l s
Long-life 150 W discharge lamp
2 m (6.5 ft) US mains cable 18AWG with US male connector (UL approved)
5 meter (16.4 ft.) RS-485 XLR cable for data link . . . . . . . . . . . . . . . . P/N 11820008
User manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 35000168
E F X 8 0 0
Paddlewheel shield for use during transport
A c c e s s o r i e s
DMX termination plug (end of link), XLR male . . . . . . . . . . . . . . . . . . P/N 91613017
DMX termination plug, (start of link, master/slave), XLR female. . . . . P/N 91613018
G-clamp. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 91602003
Half-coupler clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 91602005
5-pin male to 3-pin female XLR adaptor cable . . . . . . . . . . . . . . . . . . P/N 11820005
5 meter (16.4 ft.) RS-485 XLR cable for data link . . . . . . . . . . . . . . . . P/N 11820008
E F X 5 0 0 , a l l m o d e l s
Philips ELC 10H 250 W halogen lamp . . . . . . . . . . . . . . . . . . . . . . . . P/N 97000109
Main fuse, 3.15 AT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 05020043
E F X 6 0 0 , E F X 7 0 0 & E F X 8 0 0 , E U m o d e l s
Philips CDM SA-T 150 W discharge lamp. . . . . . . . . . . . . . . . . . . . . . P/N 97010111
Osram HSD 150/70 150 W discharge lamp . . . . . . . . . . . . . . . . . . . . P/N 97010117
Main fuse, 2 AT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 05020009
E F X 6 0 0 , E F X 7 0 0 & E F X 8 0 0 , U S m o d e l s
Philips CDM SA-T 150 W discharge lamp. . . . . . . . . . . . . . . . . . . . . . P/N 97010111
Osram HSD 150/70 150 W discharge lamp . . . . . . . . . . . . . . . . . . . . P/N 97010117
Main fuse, 3.15 AT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 05020043
O r d e r i n g i n f o r m a t i o n
Mania EFX500, 115/230 V, 50/60 Hz . . . . . . . . . . . . . . . . . . . . . . . . . P/N 90430050
Mania EFX600 EU model, 220-240 V, 50 Hz . . . . . . . . . . . . . . . . . . . P/N 90430052
Mania EFX600 US model, 110-120 V, 60 Hz . . . . . . . . . . . . . . . . . . . P/N 90430053
Mania EFX700 EU model, 220-240 V, 50 Hz . . . . . . . . . . . . . . . . . . . P/N 90430054
Mania EFX700 US model, 110-120 V, 60 Hz . . . . . . . . . . . . . . . . . . . P/N 90430055
Mania EFX800 EU model, 220-240 V, 50 Hz . . . . . . . . . . . . . . . . . . . P/N 90430056
Mania EFX800 US model, 110-120 V, 60 Hz . . . . . . . . . . . . . . . . . . . P/N 90430057
Disposing of this product
Martin
®
products are supplied in compliance with Directive
2002/96/EC of the European Parliament and of the Council of the
European Union on WEEE (Waste Electrical and Electronic
Equipment), as amended by Directive 2003/108/EC, where applicable.
Help preserve the environment! Ensure that this product is recycled at the end of its life. Your supplier can give details of local arrangements for the disposal of Martin
®
products.
Ø13.5
A
40
Ø9
Ø18
A
50
40
A
50
www.martin.com • Olof Palmes Allé 18 • 8200 Aarhus N • Denmark
Tel: +45 8740 0000 • Fax +45 8740 0010
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 4 Overview
- 5 Introduction
- 5 Safety information
- 5 Protecting yourself and others from electric shock
- 6 Protecting yourself and others from burns and fire
- 7 Preventing injuries due to falls
- 7 Discharge lamp safety
- 7 Unpacking
- 8 Removing protective packaging
- 9 Installation
- 9 AC power
- 10 Power plugs
- 10 Physical installation
- 11 Beam angles and fixture orientation
- 11 Surface mounting
- 12 Overhead mounting
- 13 Creating a data link for DMX and synchronized operation
- 13 Connecting the serial data link
- 14 Gobo wheels
- 17 Operation
- 17 Getting started
- 17 Powering on
- 17 Music trig, auto trig and DMX modes
- 18 Selecting DMX, music trig or auto trig operating modes
- 18 Synchronized music trig and auto trig operation
- 19 Setting up synchronized operation
- 19 DMX controller operation
- 19 Setting DMX mode 1 or 2
- 20 Setting DMX addresses
- 21 DMX control options
- 22 Unsure about speed and tracking?
- 22 DMX signal indicator
- 23 Changing personality settings
- 23 Adjusting music trig sensitivity
- 24 Inverting effects movement
- 25 Error messages
- 25 Restriking the discharge lamp
- 26 Adjusting focus
- 27 Service and maintenance
- 27 Cleaning
- 27 Cleaning the fan and air vents
- 28 Cleaning optical components
- 28 Lamp replacement and adjustment
- 28 Halogen lamp (Mania EFX500)
- 29 Discharge lamp (EFX600, EFX700 & EFX800)
- 31 Replacing the main fuse
- 32 Firmware and hard boot uploads
- 33 Circuit board layouts
- 36 Troubleshooting
- 37 Control panel overview
- 37 EFX500 and EFX600 control panel settings
- 37 EFX700 control panel settings
- 37 EFX800 control panel settings
- 38 Mania EFX500 DMX protocol
- 41 Mania EFX600 DMX protocol
- 44 Mania EFX700 DMX protocol
- 46 Mania EFX800 DMX protocol
- 49 Mania EFX Series specifications