VENTILATION TOWERS

System FSC

VENTILATION TOWERS System FSC

FSC (VENTILATION TOWERS)

Free-standing, single-walled supply air and discharge air chimney. Corrosion addition or paint coating is also resistant to discharge air. Inexpensive alternatives to the FSA for non-hazardous material discharge air.

60

INTAKE TOWER

Conclusion

Bird screen

Segments 180° - 360° with or without raised edge

DISCHARGE TOWER

Steel pipe stainless steel ground K180

Water separator

Water drain

Base plate

VENTILATION TOWERS System FSC

USE

> The FSC series is used in air conditioning and ventilation technology

STRUCTURE

> In FSC, the visible pipe is the static supporting system and also the media-carrying system that is usually not insulated

> Depending on requirement, thicknesses of above 1.5 mm for stainless steel and 4 mm for carbon steel are manufactured

FIXTURES

> Segment hoods, steam arcs, acceleration jets or deflector hood

SUPPLEMENTS

> A water separator that cannot be seen from outside can be built into the supporting pipe. The benefit is that the resistance coefficient for the Jeremias water separator is significantly lower that of a deflector hood; the function is identical

SERIES

STATIC SYSTEM

FSC

Foundation basket or building Connection

SUPPORTING ELEMENT Single-walled exhaust line

STRUCTURE Single-shell

INTERNAL PIPE

INTERNAL PIPE

DAMPING

REAR VENTILATION

Possible for discharge air

Insulation with Armaflex is possible

-

SUPPORTING PIPE

SURFACE VISUAL

USE

1.4301, 1.4571, St 37-2

Facet grinding for stainless steel

Steel, galvanised

Steel, coated

(Cladding)

Supply air, discharge air

61

VENTILATION TOWERS System FSC

CAMBRILLS,

SPAIN

BÜNDE,

GERMANY

FRANKFURT,

GERMANY

HEIGHT

DIAMETER

SURFACE:

18 m

2760 mm matte, with ground welded seams

HEIGHT

DIAMETER

SURFACE:

One-piece transport to Spain.

Assembly with 3.5 m high segmenthoods.

metal process.

3,2 m

2 x 1600 /

6 x 20000 mm ground

8 FSC for exhaust air and supply of a

HEIGHT

DIAMETER

SURFACE:

8.2 m/ 4.8 m

1600/1300 mm ground

Discharge air and supply air in the Frankfurt University clinic

KÜNZELSAU,

GERMANY

NÜRBURGRING,

GERMANY

MUTLANGEN,

GERMANY

HEIGHT

DIAMETER

SURFACE:

2 x 11 m

1000 mm glass-pearl blasted

HEIGHT

DIAMETER

SURFACE:

5 x 4,3 m

2250 mm ground

HEIGHT

DIAMETER

SURFACE:

2 x 11 m

1000 mm ground segment hood 360°, flush on supporting pipe. Adjacent to supply air connection from below.

5 supply air towers for the Dorint hotel at the Nürburgring

Architectonically adapted discharge-

/supply air towers with visible, interior water separator

62

VENTILATION TOWERS System FSC

INTAKE TOWERS OVERVIEW

SEGMENT HEAD VARIATIONS

Exactly 0°

LAMINATE FORM

Pitched roof 3-45° Cone roof 3-30°

45° without raised edge

45° with raised edge

LAMINATE CONFIGURATION

Flush Projecting

360° 180°

63

64

VENTILATION TOWERS System FSC

OUTLET TOWER OVERVIEW

CONCLUSION WATER SEPARATOR

Directly with bird screen

Diagonal cut 3-45° with bird screen

Deflector hood Steam arc 90°

Segment separator on base

Multiphase separator

VENTILATION TOWERS System FSC

SEALING

To add the ventilation tower to the substrate and waterproofed it usually needs to be incorporated into the roof cladding. In addition, there are various options that can be designed depending on the substrate / roof construction

Clamp flange for affixing the roof cladding on the bottom flange

Clamp ring for affixing the roof cladding underneath the weather protection cover

65

VENTILATION TOWERS System FSC

INTAKE TOWERS

CUSTOMER DATA

Customer name

Contact person

Phone

Email

DATA

Installation location

Air power

Air speed

Sound level

Pressure loss max.

Temperature/medium

Diameter

Wall thickness

Total height

Segment hood height

Standing pipe height

Material

Fittings

Surface

Segment hood

Segment hood design m³/h m/s dB(A)

Pa

°C / mm Jeremias design mm Jeremias design mm mm Jeremias design mm

1.4301 1.4571

Other

Foundation basket

Foundation basket with sheathing pipe

Foundation bolts

Mount

According to static

Ground K180

Matte

Glass-pearl blasted

Other

180° 360°

Without raised edge External raised edge

Tower roof incline

Material base point

Connection

Cleaning opening

Sealing/clamping fitting

Planned execution time

66

0° 15° 30° Cone roof

Such as standing pipe (VA) Ground/coated steel

Sideways 45° Sideways 87 - 90°

Size corresponding diameter Standard Jeremias

From below

Size

Weather protection cover in stainless steel Transport Assembly incl. crane mm

VENTILATION TOWERS System FSC

COMBINATION TOWERS

CUSTOMER DATA

Customer name

Contact person

Phone

Email

DATA

Installation location

Air power intake

Air power steam off

Air speed

Sound level

Pressure loss max.

Temperature / medium m³/h m³/h m/s dB(A)

Pa

°C /

EXTERNAL PART (INTAKE PIPE WITH SEGMENT HOOD)

Diameter mm Jeremias design

Wall thickness

Total height

Segment hood height

Standing pipe height

Material

Fittings

Surface

Segment hood

Segment hood design mm Jeremias design mm mm Jeremias design mm

1.4301 1.4571

Other

Foundation basket

Foundation basket with sheathing pipe

Foundation bolts

Mount

According to static

Ground K180

Matte

Glass-pearl blasted

Other

180° 360°

Without raised edge External raised edge

Material base point

Connection

Cleaning opening

Such as standing pipe (VA) Ground steel

Sideways 45° Sideways 87 - 90°

Size corresponding diameter Standard Jeremias

From below

Size

Sealing/clamping fixture Weather protection cover in stainless steel mm

67

VENTILATION TOWERS System FSC

COMBINATION TOWERS

INTERIOR PART

(STEAM OFF PIPE WITH SEGMENT SEPARATOR)

Diameter

Wall thickness

Total height

Material

Steam off opening

Connection

1.4301

Other

Open steam off

Sideways 45°

From below mm Jeremias design mm Jeremias design mm

1.4571

90° steam arc

Sideways 87 - 90°

Transport

Assembly incl. crane

Planned execution time

68

VENTILATION TOWERS System FSC

DISCHARGE TOWERS

CUSTOMER DATA

Customer name

Contact person

Phone

Email

DATA

Installation location

Air power

Air speed

Sound level

Pressure loss max.

Temperature/medium

Total height

Material

Fittings

Surface

Steam off opening

Design of blind segment m³/h m/s dB(A)

Pa

°C / mm

1.4301 1.4571

Other

Foundation basket

Foundation basket with sheathing pipe

Foundation bolts

Mount

according to static

ground K180

Matte

Glass-pearl blasted

Other

Open steam off

90° Steam arc

Segment hood without function

(blind segment)

Without raised edge External raised edge

Segment separator

Opening / Diagonal cut

Material base point

Connection

Cleaning opening

Sealing/clamping fitting

Assembly incl. crane

According to Jeremias - Standard

0° 15° 30°

Such as standing pipe (VA) Ground/coated steel

Cone roof

Sideways 45° Sideways 87 - 90°

Size corresponding diameter Standard Jeremias Size

From below mm

Weather protection cover in stainless steel

Planned execution time

Transport

69

advertisement

Key Features

  • Free-standing, single-walled design.
  • Inexpensive alternative to FSA for non-hazardous material discharge air.
  • Suitable for both supply air and discharge air applications.
  • Visible pipe serves as both static supporting system and media-carrying system.
  • Available in a range of thicknesses and materials to meet specific requirements.
  • Can be equipped with various fixtures and accessories, such as segment hoods, steam arcs, and water separators.

Related manuals

Frequently Answers and Questions

What is the purpose of the Dantherm FSC Jeremias?
The Dantherm FSC Jeremias is a free-standing, single-walled supply air and discharge air chimney. It is used in air conditioning and ventilation technology.
What are the benefits of using the Dantherm FSC Jeremias?
The Dantherm FSC Jeremias is an inexpensive alternative to the FSA for non-hazardous material discharge air. It is also easy to install and maintain.
What are the different types of fixtures and accessories available for the Dantherm FSC Jeremias?
The Dantherm FSC Jeremias can be equipped with a variety of fixtures and accessories, such as segment hoods, steam arcs, and water separators.
Download PDF

advertisement