DT594 USER MANUAL(EN)

2-Wire Video Intercom System

 Read this manual carefully before using the product, and keep it well for future use.

Introduction

The door station is designed with high resolution color CCD camera, it provides wide angle of 105

0

for DT 2-wire intercom system. The high white LED for night view makes the door station working efficiently at night.

The front panel is made of plexiglass or stainless steel with rainy cover for better protection against water. One or two touch sensor call button can be selected. The large name label with white backlight is covered by a fully secured and flameproof glass plate.

Parts and Function

35.6

Camera Lens

Night View LED

Speaker

Nameplate

Call Button

Microphone

92

22

Note:the door station support two call buttons to control two users.

Rainy Cover

Terminal Description

Doorstation Code DIP

T/R+ T/R-

1 2 3

Lock Control Jumper

Connection line

BUS(Blue&Green)

S2+(Red)

PL(White)

S1+(Yellow)

S1-(Black)

-2-

Lock Control Jumper:

To select the lock type.

Door Station Code DIP:

Total 4 door stations can be supported.

T/R+,T/R-: USB-RS485 communication terminal.

Main Connect Port: To connect the bus line and the electronic locks.

BUS(Blue&Green): Connect to the bus line, non-polarity.

PL(White): External lock power input, connect to the power positive(power +).

S1+(Yellow): The first lock power(+) output.

S2+(Red): The second lock power(+) output.

S-(Black): Lock power(-) output.

Door Station Mounting

Mounting with rainy cover

1 2 3

Mounting without rainy cover

1 2 3

-3-

The location of the unit should keep away from snow,rain,and intensity light.

Installation Steps:

Installation height for door station usually is 145~160cm.

1. Use screws to fix the back panel and rainy cover(if mounting with rainy cover) to the wall after connect the cable correctly.

2. Attach the front panel to the back panel, then use the screw to fix it.

Adjusting Camera Angle

Use a screwdriver to loosen the screw and then adjust the angle of the camera ,then fix the screw.

System Wiring and Connections

Basic one-to-one Connection

-4-

Bus PL S1+ S2+ S-

-

+

AC~

PC6 monitor

Multi Door Stations Connection

4# Camera

ID=11

ON

1 2

3# Camera

ID=01

ON

1 2

2# Camera

ID=10

ON

1 2

1# Camera

ID=00

ON

1 2

Bus PL S1+ S2+ SBus PL S1+ S2+ SBus PL S1+ S2+ SBus PL S1+ S2+ Smonitors

DIP=on,off,off

A B C D

DBC-4S

OFF

ON

85~260VAC

AC~

PC6

Multi Monitors Connection

ON

1 2 3 4 5 6

Code=0, DIP-6=off monitor

ON

1 2 3 4 5 6

Code=1, DIP-6=off monitor

ON

1 2 3 4 5 6

Code=14, DIP-6=off monitor

ON

1 2 3 4 5 6

Code=15, DIP-6=on monitor

AC~

PC6

ID=00

ON

1 2

-5-

With DBC-4S Wiring Mode

ON

1 2 3 4 5 6

Code=15, DIP-6=on monitor

ON

1 2 3 4 5 6

Code=14, DIP-6=on monitor

ON

1 2 3 4 5 6

Code=13, DIP-6=on monitor

ON

1 2 3 4 5 6

Code=12, DIP-6=on monitor

ON

1 2 3 4 5 6

Code=3, DIP-6=on monitor

ON

1 2 3 4 5 6

Code=1, DIP-6=on monitor

ON

1 2 3 4 5 6

Code=2, DIP-6=on monitor

ON

1 2 3 4 5 6

Code=0, DIP-6=on monitor

AC~

PC6

OFF ON

DIP=on,off,off

OFF ON

DIP=on,off,off

ID=00

ON

1 2

-6-

Electric Lock Connection

Door Lock Controlled with Internal Power

Note:

1. Electronic lock of Power-on-to-unlock type should be used.

2. The door lock is limited to 12V, and holding current must be less than

250mA.

3. The door lock control is not timed from Exit Button(EB).

4. The Unlock Mode Parameter of Monitor must be set to 0 (by default).

connect one lock

1 2 3

Connect one lock

Jumper position in 2-3 connect two locks

1 2 3

Connect two locks

Jumper position in 2-3

BUS PL S1+ S2+ S-

BUS PL S1+ S2+ S-

*

EB

1

ST

*

EB

LOCK

LOCK

2 nd

*

EB

2 nd

Door Lock Controlled with Dry Contact

Note:

1. The external power supply must be used according to the lock.

2. Setup the Unlock Mode of Monitor for different lock types.

• Power-on-to-unlock type:Unlock Mode=0 (by default)

• Power-off-to-unlock type:Unlock Mode=1

LOCK

1

ST

-7-

connect one lock

Take off the Jumper

BUS PL S1+ S2+ SBUS connect two locks

Take off the Jumper

PL S1+ S2+ S-

POWER

SUPPLY

POWER

SUPPLY

LOCK LOCK

LOCK

5.2.3 Unlock parameter setting(set on monitor)

Manual

Monitor

Monitor Intercom

Multimedia

Memory

Playback

Album

1.Touch menu page.

Installation settings:

User Setup

Close

09/30/2010 Thu.16:41

item on main

[8002]#:Set as slaver unit 2

[8003]#:Set as slaver unit 3

[8005]#:Set as not guard unit

[8006]#:Panel on as slaver unit called

[8008]#:Date format:MM/DD/YYYY

[8010]#:Set lock mode to 0

Code Number:[----]

1

4

2

5

3

6

7 8

0

9

Cancel

4.A digital keypad and setting instructions will be shown.

H/W : --- a1.3

S/W: V17.11.418.00

Local addr: ---

Unlock timing: ---

Video standard: -

UI-CODE: ---

MCM-VER.: ---

Updated: ---

2.Touch the screen anywhere and hold for 2s.

Installer setup

Caliber

TouchScreen

Home

3.Touch Installer setup item

Note:

1.must connect correctly before setting.

2.the parameter will be saved in door station automatically,so you need only set on one monitor.

3.the above diagram is fit for icon menu series monitors only, to text menu series monitors,please refer to the corresponding user manual.

-8-

DIP Switches Setting

The DIP switch is designed to set the code for door station and monitor, there are two states for each DIP switch, please refer to the sketch map.

ON

ON(1)

=

ON

OFF(0)

=

Door station DIP setting

Total 2 bits can be configured, bit-1 and bit-2 are used to assign ID code for door station.The switches can be modified either before or after installation.

Bit state

ON

1 2

ON

1 2

ON

1 2

ON

1 2

Descriptions

Default setting, ID = 0(00), set to the first Door Station.

ID = 1(10), set to the second Door Station.

ID = 2(01), set to the third Door Station.

ID = 3(11), set to the fourth Door Station.

Indoor monitor DIP setting

There are 6 bits in total. The DIP switches are used to configure the user code for Monitors.

Bit-6 is an video impedance match switch, which have to be set to ON if match the impedance, otherwise set to OFF.

Bit state Setting Bit state

ON

1 2 3 4 5 6

Not match

ON

1 2 3 4 5 6

Setting

Match the video impedance

Bit-1~Bit-5 are used to set user code. If the door station with one call button, the user code should be set to 0~15. If the door station with two call buttons, the user code should be set to 0~31.

Please refer to the following settings:

-9-

Bit state

ON

1 2 3 4 5 6

ON

1 2 3 4 5 6

ON

1 2 3 4 5 6

ON

1 2 3 4 5 6

ON

1 2 3 4 5 6

ON

1 2 3 4 5 6

ON

1 2 3 4 5 6

ON

1 2 3 4 5 6

ON

1 2 3 4 5 6

ON

1 2 3 4 5 6

ON

1 2 3 4 5 6 code=6 code=7 code=8 code=9 code=10

User code code=0 code=1 code=2 code=3 code=4 code=5

Bit state

ON

1 2 3 4 5 6

ON

1 2 3 4 5 6

ON

1 2 3 4 5 6

ON

1 2 3 4 5 6

ON

1 2 3 4 5 6

ON

1 2 3 4 5 6

ON

1 2 3 4 5 6

ON

1 2 3 4 5 6

ON

1 2 3 4 5 6

ON

1 2 3 4 5 6

ON

1 2 3 4 5 6

User code code=11 code=12 code=13 code=14 code=15 code=16 code=17 code=18 code=19 code=20 code=21

Bit state

ON

1 2 3 4 5 6

ON

1 2 3 4 5 6

ON

1 2 3 4 5 6

ON

1 2 3 4 5 6

ON

1 2 3 4 5 6

ON

1 2 3 4 5 6

ON

1 2 3 4 5 6

ON

1 2 3 4 5 6

ON

1 2 3 4 5 6

ON

1 2 3 4 5 6

User code code=22 code=23 code=24 code=25 code=26 code=27 code=28 code=29 code=30 code=31

B

A

Note:Monitors response button A must set the user code from 0 to 15.and button B set the user code from 16 to 31.

-10-

A

Cables Requirements

The maximum distance of the wiring is limited in the DT system. Using different cables may also affect the maximum distance which the system can reach.

The farest monitor monitor with two or four monitors monitor monitor

When Monitor quantity < 20

Cable Usage

Twisted cable 2x0.75 mm 2

Twisted cable 2x1 mm 2

A B C

60 60 30

80 80 40

When Monitor quantity > 20

Cable Usage

Twisted cable 2x1 mm

2

Twisted cable 2x1.5 mm 2

A B C

70 30 20

70 50 30

Note:If the monitor has been specified the distance,refer to the parameter.

AC~

PC6

C

DBC-4S

B

A

-11-

Specification

Power Supply : DC 24V (supplied by PC6);

Power Consumption: Standby 60mA; Working status 200mA;

Camera: 1/4 ACS 4T image sensor with DSP processor

Lock Power supply: 12Vdc, 300mA(Internal Power);

Working temperature: -10ºC ~ +45ºC

Dimension: 188(H)×110(W)×34(D)mm

Precautions

• Please clean the unit with soft cotton cloth, don't use the organic impregnant or chemical clean agent. If necessary, please use a little pure water or dilute soap water to clean the dust.

• The unit is weather resistant. However do not spray high pressure water on access control keypad directly. Excessive moisture may cause problems with the unit.

• You must use the right adaptor which is supplied by the manufacturer or approved by the manufacturer.

• Pay attention to the high voltage inside the products, please refer service only to a trained and qualified professional.

The design and specifications can be changed without notice to the user. Right to interpret and copyright of this manual are preserved.

DT-ENG-594-V1 P130422

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement