The 2easy DT594 is a 2-wire video intercom system that provides wide-angle viewing, night vision, and supports up to four door stations and multiple monitors. It features a high-resolution color CCD camera with a 1050 viewing angle and high white LED for clear night vision, making it suitable for various security and communication needs. With its durable construction and weather-resistant design, the 2easy DT594 is built to withstand harsh outdoor conditions.
advertisement
DT594 USER MANUAL(EN)
2-Wire Video Intercom System
Read this manual carefully before using the product, and keep it well for future use.
Introduction
The door station is designed with high resolution color CCD camera, it provides wide angle of 105
0
for DT 2-wire intercom system. The high white LED for night view makes the door station working efficiently at night.
The front panel is made of plexiglass or stainless steel with rainy cover for better protection against water. One or two touch sensor call button can be selected. The large name label with white backlight is covered by a fully secured and flameproof glass plate.
Parts and Function
35.6
Camera Lens
Night View LED
Speaker
Nameplate
Call Button
Microphone
92
22
Note:the door station support two call buttons to control two users.
Rainy Cover
Terminal Description
Doorstation Code DIP
T/R+ T/R-
1 2 3
Lock Control Jumper
Connection line
BUS(Blue&Green)
S2+(Red)
PL(White)
S1+(Yellow)
S1-(Black)
-2-
Lock Control Jumper:
To select the lock type.
Door Station Code DIP:
Total 4 door stations can be supported.
T/R+,T/R-: USB-RS485 communication terminal.
Main Connect Port: To connect the bus line and the electronic locks.
BUS(Blue&Green): Connect to the bus line, non-polarity.
PL(White): External lock power input, connect to the power positive(power +).
S1+(Yellow): The first lock power(+) output.
S2+(Red): The second lock power(+) output.
S-(Black): Lock power(-) output.
Door Station Mounting
Mounting with rainy cover
1 2 3
Mounting without rainy cover
1 2 3
-3-
The location of the unit should keep away from snow,rain,and intensity light.
Installation Steps:
Installation height for door station usually is 145~160cm.
1. Use screws to fix the back panel and rainy cover(if mounting with rainy cover) to the wall after connect the cable correctly.
2. Attach the front panel to the back panel, then use the screw to fix it.
Adjusting Camera Angle
Use a screwdriver to loosen the screw and then adjust the angle of the camera ,then fix the screw.
System Wiring and Connections
Basic one-to-one Connection
-4-
Bus PL S1+ S2+ S-
-
+
AC~
PC6 monitor
Multi Door Stations Connection
4# Camera
ID=11
ON
1 2
3# Camera
ID=01
ON
1 2
2# Camera
ID=10
ON
1 2
1# Camera
ID=00
ON
1 2
Bus PL S1+ S2+ SBus PL S1+ S2+ SBus PL S1+ S2+ SBus PL S1+ S2+ Smonitors
DIP=on,off,off
A B C D
DBC-4S
OFF
ON
85~260VAC
AC~
PC6
Multi Monitors Connection
ON
1 2 3 4 5 6
Code=0, DIP-6=off monitor
ON
1 2 3 4 5 6
Code=1, DIP-6=off monitor
ON
1 2 3 4 5 6
Code=14, DIP-6=off monitor
ON
1 2 3 4 5 6
Code=15, DIP-6=on monitor
AC~
PC6
ID=00
ON
1 2
-5-
With DBC-4S Wiring Mode
ON
1 2 3 4 5 6
Code=15, DIP-6=on monitor
ON
1 2 3 4 5 6
Code=14, DIP-6=on monitor
ON
1 2 3 4 5 6
Code=13, DIP-6=on monitor
ON
1 2 3 4 5 6
Code=12, DIP-6=on monitor
ON
1 2 3 4 5 6
Code=3, DIP-6=on monitor
ON
1 2 3 4 5 6
Code=1, DIP-6=on monitor
ON
1 2 3 4 5 6
Code=2, DIP-6=on monitor
ON
1 2 3 4 5 6
Code=0, DIP-6=on monitor
AC~
PC6
OFF ON
DIP=on,off,off
OFF ON
DIP=on,off,off
ID=00
ON
1 2
-6-
Electric Lock Connection
Door Lock Controlled with Internal Power
Note:
1. Electronic lock of Power-on-to-unlock type should be used.
2. The door lock is limited to 12V, and holding current must be less than
250mA.
3. The door lock control is not timed from Exit Button(EB).
4. The Unlock Mode Parameter of Monitor must be set to 0 (by default).
connect one lock
1 2 3
Connect one lock
Jumper position in 2-3 connect two locks
1 2 3
Connect two locks
Jumper position in 2-3
BUS PL S1+ S2+ S-
BUS PL S1+ S2+ S-
*
EB
1
ST
*
EB
LOCK
LOCK
2 nd
*
EB
2 nd
Door Lock Controlled with Dry Contact
Note:
1. The external power supply must be used according to the lock.
2. Setup the Unlock Mode of Monitor for different lock types.
• Power-on-to-unlock type:Unlock Mode=0 (by default)
• Power-off-to-unlock type:Unlock Mode=1
LOCK
1
ST
-7-
connect one lock
Take off the Jumper
BUS PL S1+ S2+ SBUS connect two locks
Take off the Jumper
PL S1+ S2+ S-
POWER
SUPPLY
POWER
SUPPLY
LOCK LOCK
LOCK
5.2.3 Unlock parameter setting(set on monitor)
Manual
Monitor
Monitor Intercom
Multimedia
Memory
Playback
Album
1.Touch menu page.
Installation settings:
User Setup
Close
09/30/2010 Thu.16:41
item on main
[8002]#:Set as slaver unit 2
[8003]#:Set as slaver unit 3
[8005]#:Set as not guard unit
[8006]#:Panel on as slaver unit called
[8008]#:Date format:MM/DD/YYYY
[8010]#:Set lock mode to 0
Code Number:[----]
1
4
2
5
3
6
7 8
0
9
Cancel
4.A digital keypad and setting instructions will be shown.
H/W : --- a1.3
S/W: V17.11.418.00
Local addr: ---
Unlock timing: ---
Video standard: -
UI-CODE: ---
MCM-VER.: ---
Updated: ---
2.Touch the screen anywhere and hold for 2s.
Installer setup
Caliber
TouchScreen
Home
3.Touch Installer setup item
Note:
1.must connect correctly before setting.
2.the parameter will be saved in door station automatically,so you need only set on one monitor.
3.the above diagram is fit for icon menu series monitors only, to text menu series monitors,please refer to the corresponding user manual.
-8-
DIP Switches Setting
The DIP switch is designed to set the code for door station and monitor, there are two states for each DIP switch, please refer to the sketch map.
ON
ON(1)
=
ON
OFF(0)
=
Door station DIP setting
Total 2 bits can be configured, bit-1 and bit-2 are used to assign ID code for door station.The switches can be modified either before or after installation.
Bit state
ON
1 2
ON
1 2
ON
1 2
ON
1 2
Descriptions
Default setting, ID = 0(00), set to the first Door Station.
ID = 1(10), set to the second Door Station.
ID = 2(01), set to the third Door Station.
ID = 3(11), set to the fourth Door Station.
Indoor monitor DIP setting
There are 6 bits in total. The DIP switches are used to configure the user code for Monitors.
Bit-6 is an video impedance match switch, which have to be set to ON if match the impedance, otherwise set to OFF.
Bit state Setting Bit state
ON
1 2 3 4 5 6
Not match
ON
1 2 3 4 5 6
Setting
Match the video impedance
Bit-1~Bit-5 are used to set user code. If the door station with one call button, the user code should be set to 0~15. If the door station with two call buttons, the user code should be set to 0~31.
Please refer to the following settings:
-9-
Bit state
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6 code=6 code=7 code=8 code=9 code=10
User code code=0 code=1 code=2 code=3 code=4 code=5
Bit state
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
User code code=11 code=12 code=13 code=14 code=15 code=16 code=17 code=18 code=19 code=20 code=21
Bit state
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
User code code=22 code=23 code=24 code=25 code=26 code=27 code=28 code=29 code=30 code=31
B
A
Note:Monitors response button A must set the user code from 0 to 15.and button B set the user code from 16 to 31.
-10-
A
Cables Requirements
The maximum distance of the wiring is limited in the DT system. Using different cables may also affect the maximum distance which the system can reach.
The farest monitor monitor with two or four monitors monitor monitor
When Monitor quantity < 20
Cable Usage
Twisted cable 2x0.75 mm 2
Twisted cable 2x1 mm 2
A B C
60 60 30
80 80 40
When Monitor quantity > 20
Cable Usage
Twisted cable 2x1 mm
2
Twisted cable 2x1.5 mm 2
A B C
70 30 20
70 50 30
Note:If the monitor has been specified the distance,refer to the parameter.
AC~
PC6
C
DBC-4S
B
A
-11-
Specification
Power Supply : DC 24V (supplied by PC6);
Power Consumption: Standby 60mA; Working status 200mA;
Camera: 1/4 ACS 4T image sensor with DSP processor
Lock Power supply: 12Vdc, 300mA(Internal Power);
Working temperature: -10ºC ~ +45ºC
Dimension: 188(H)×110(W)×34(D)mm
Precautions
• Please clean the unit with soft cotton cloth, don't use the organic impregnant or chemical clean agent. If necessary, please use a little pure water or dilute soap water to clean the dust.
• The unit is weather resistant. However do not spray high pressure water on access control keypad directly. Excessive moisture may cause problems with the unit.
• You must use the right adaptor which is supplied by the manufacturer or approved by the manufacturer.
• Pay attention to the high voltage inside the products, please refer service only to a trained and qualified professional.
The design and specifications can be changed without notice to the user. Right to interpret and copyright of this manual are preserved.
DT-ENG-594-V1 P130422