SIMATIC RF200
SIMATIC Ident
RFID systems
SIMATIC RF200
System Manual
09/2013
J31069-D0227-U001-A8-7618
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger.
DANGER indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION indicates that minor personal injury can result if proper precautions are not taken.
NOTICE indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions.
Siemens AG
Industry Sector
Postfach 48 48
90026 NÜRNBERG
GERMANY
Order number: J31069-D0227-U001
Ⓟ 10/2013 Technical data subject to change
Copyright © Siemens AG 2010 - 2013.
All rights reserved
Table of contents
2
3
1
4
5
3.1
3.2
4.1
4.1.1
4.1.2
4.1.3
4.1.4
4.1.5
4.1.6
4.1.7
4.1.8
4.2
4.2.1
4.2.2
4.3
4.3.1
4.3.2
4.3.3
4.3.4
4.3.5
4.4
5.1
5.1.1
5.1.2
5.1.3
5.1.4
5.1.5
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 5
Table of contents
6
5.4
5.4.1
5.4.2
5.4.3
5.4.4
5.4.5
5.4.6
5.4.7
5.3
5.3.1
5.3.2
5.3.3
5.3.4
5.3.5
5.3.6
5.3.7
5.3.8
5.1.6
5.1.7
5.1.8
5.2
5.2.1
5.2.2
5.2.3
5.2.4
5.2.5
5.2.6
5.2.7
5.2.8
5.5
5.5.1
5.5.2
5.5.3
5.5.4
5.5.5
5.5.6
5.5.7
5.5.8
5.6
5.6.1
5.6.2
5.6.3
5.6.4
5.6.5
5.6.6
5.6.7
5.6.8
Note on the use of the RF290R as a replacement for SLG D10 / SLG D10S .......................... 115
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Table of contents
6
6.6
6.6.1
6.6.2
6.6.3
6.6.4
6.6.5
6.6.6
6.5
6.5.1
6.5.2
6.5.3
6.5.4
6.5.5
6.5.6
6.5.7
6.4
6.4.1
6.4.2
6.4.3
6.4.4
6.4.5
6.4.6
6.4.7
6.3
6.3.1
6.3.2
6.3.3
6.3.4
6.3.5
6.3.6
6.3.7
5.6.9
6.2
6.2.1
6.2.2
6.2.3
6.2.4
6.2.5
6.2.6
6.2.7
6.1
6.1.1
6.1.2
6.1.3
6.1.4
6.1.5
6.1.6
6.1.7
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 7
8
Table of contents
7
7.5
7.5.1
7.5.2
7.5.3
7.5.4
7.5.5
7.6
7.6.1
7.6.2
7.6.3
7.6.4
7.6.5
7.6.6
7.3
7.3.1
7.3.2
7.3.3
7.3.4
7.3.5
7.3.6
7.4
7.4.1
7.4.2
7.4.3
7.4.4
7.1
7.1.1
7.1.2
7.1.3
7.1.4
7.1.5
7.2
7.2.1
7.2.2
7.2.3
7.2.4
7.2.5
6.6.7
6.7
6.7.1
6.7.2
6.7.3
6.7.4
6.7.5
6.7.6
6.7.7
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Table of contents
7.7
7.7.1
7.7.2
7.7.3
7.7.4
7.7.5
7.8
7.8.1
7.8.2
7.8.3
7.8.4
7.9
7.9.1
7.9.2
7.9.3
7.9.4
7.9.5
7.10
7.11
7.12
7.13
7.14
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 9
Table of contents
8
10
7.15
7.16
7.17
7.18
7.19
7.20
7.21
8.1
8.2
8.2.1
8.2.2
8.2.3
8.2.4
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Table of contents
9
10
10.1
10.2
A
8.2.5
8.2.6
8.2.7
8.2.8
8.2.9
8.3
8.3.1
8.3.2
8.3.3
8.3.4
8.3.5
8.3.6
8.3.7
8.3.8
8.3.9
A.1
A.2
A.2.1
A.2.2
A.2.3
A.3
A.4
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 11
Table of contents
12
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Introduction
1
Introduction
SIMATIC RF200 is a compact RFID system in the SIMATIC RF product family. The product range comprises cost-efficient RF readers that are ideal for use in small assembly lines or in intralogistics. SIMATIC RF200 RFID readers only support the RFID standard ISO 15693 and are therefore ideal for operation with the extensive range of MOBY D transponders.
All readers of the RF200 product family are available with an RS-422 interface and 3964R transmission protocol (6GT2821-xAC10). These readers are designed for operation in conjunction with communications modules. To operate with third-party controllers (without communications modules), RF200 reader variants are available with an RS-232 interface
(RF240R/RF250R/RF260R/RF290R). Depending on the reader type and order number, communication is with the 3964R transmission protocol or with simple ASCII communication.
Readers with an internal antenna have a particularly compact design
(RF210R/RF220R/RF240R/RF260R). RF250R and RF290R are designed for operation with external antennas either to achieve longer distances or larger field sizes (RF290R with ANT
D5/D6/D10) or to allow installation where there is very little space (RF250R with ANT
8/12/18/30).
Scope of validity of this document
This documentation is valid for all variants of the SIMATIC RF200 system and describes the devices shipped as of September 2013.
Registered trademarks
SIMATIC ® is a registered trademark of the Siemens AG.
Further information
You will find more detailed information in MOBY D System Manual
( http://support.automation.siemens.com/WW/view/en/13628689/0/en ), Function Manual FB
45 ( http://support.automation.siemens.com/WW/view/en/21738808 ) or in RF300 system manual ( http://support.automation.siemens.com/WW/view/en/21738946 ).
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 13
Introduction
History
The following issues of the SIMATIC RF200 system manual have been published:
Output
03/2011
05/2011
09/2011
03/2013
09/2013
Note
First edition
Expansion of the documentation with the addition of the device variant RF260R with
RS-232 interface
Expansion of the documentation with the device variant RF240R
Expansion of the documentation with the device variant RF290R
Expansion of the documentation by the following:
• the device variant RF250R
• the device variants RF240R and RF260R with ASCII interface
• Antennas ANT 8, ANT 12, ANT 18 and ANT 30
• Transponders
14
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Safety notes
2
SIMATIC RFID products comply with the salient safety specifications to IEC, VDE, EN, UL and CSA. If you have questions about the validity of the installation in the planned environment, please contact your service representative.
NOTICE
Alterations to the devices are not permitted.
Failure to observe this requirement shall constitute a revocation of the radio equipment approval, CE approval and manufacturer's warranty.
Repairs
Repairs may only be carried out by authorized qualified personnel.
WARNING
Unauthorized opening of and improper repairs to the device may result in substantial damage to equipment or risk of personal injury to the user.
System expansion
Only install system expansion devices designed for this device. If you install other upgrades, you may damage the system or violate the safety requirements and regulations for radio frequency interference suppression. Contact your technical support team or your sales outlet to find out which system upgrades are suitable for installation.
NOTICE
If you cause system defects by installing or exchanging system expansion devices, the warranty becomes void.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 15
Safety notes
16
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
System overview
3
SIMATIC RF200 is an inductive identification system that is compatible with the ISO 15693 standard and was specially designed for use in industrial production for the control and optimization of material flows.
In contrast to SIMATIC RF300, SIMATIC RF200 is intended for RFID applications where performance requirements are not very high, for example with regard to data volume, transfer rate or diagnostics options. SIMATIC RF200 is characterized by particularly favorable prices.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 17
System overview
3.1 RFID components and their function
3.1 RFID components and their function
RF200 system components
Figure 3-1 RF200 system overview
18
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
System overview
3.1 RFID components and their function
Table 3- 1 Possible reader-transponder combinations
Transponder RF210R RF220R RF240R RF250R with
ANT 8
MDS D100
MDS D117
MDS D124
MDS D126
MDS D127
MDS D139 1)
MDS D160 2)
MDS D165
MDS D200
MDS D261
MDS D324
MDS D339
MDS D400
MDS D421
--
○
✓
--
✓
--
✓
--
--
--
✓
--
--
✓
○
--
✓
✓
--
○
✓
○
○
○
✓
○
--
○
MDS D422
MDS D423
MDS D424
MDS D425
MDS D426
MDS D428
✓
✓
✓
✓
--
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
MDS D460 ✓ ✓ ✓
1) Only with the order number 6GT2600-0AA10
--
○
✓
✓
✓
--
✓
✓
○
✓
--
✓
✓
✓
✓
--
--
--
--
✓
--
--
--
--
✓
--
--
--
--
--
--
--
--
--
--
2) Only with the order number 6GT2600-0AB10
3) in conjunction with ANT D5, D6 or D10
4) Combination recommended only in conjunction with ANT D5.
5) only in conjunction with RF310M for external antennas (6GT2803-1AC10)
RF250R with
ANT 12
✓
--
✓
--
--
✓
--
--
--
--
✓
--
--
○
✓
--
--
✓
--
✓
✓
RF250R with
ANT 18
--
--
✓
--
--
--
✓
--
--
--
✓
--
--
✓
✓
✓
✓
✓
--
✓
✓
RF250R with
ANT 30
--
○
✓
○
○
--
✓
✓
○
○
--
○
○
✓
✓
✓
✓
✓
✓
✓
✓
RF260R RF290R 3) RF310M
✓
--
✓
✓
--
✓
✓
✓
✓
✓
✓
✓
✓
--
--
✓
✓
--
✓
✓
✓
--
✓
✓
✓
✓
--
✓
✓
✓
✓
--
✓
✓
✓
--
--
✓
--
✓
--
○ / ✓ 4)
✓ 5)
✓
✓
✓
✓
✓ 5)
✓
✓
✓
✓
✓
✓
✓
✓ 5)
✓ 5)
✓
✓
✓
✓
✓
✓
✓ Combination possible
-- Combination not possible
○ Combination possible, but not recommended
For more detailed information about the SIMATIC RF310M mobile reader, please refer to the
"SIMATIC RF310M Operating Instructions
( http://support.automation.siemens.com/WW/view/en/51812642 )".
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 19
System overview
3.2 Overview of transponders
3.2 Overview of transponders
Overview of typical areas of application of ISO transponders for RF200
Transponder Area of application
MDS D100
MDS D117
From simple identification such as electronic barcode replacement or supplementation, through warehouse and distribution logistics, right up to product identification. With this transponder, the maximum ranges are achieved in combination with the SIMATIC RF260R reader.
Very compact data carrier that can be cemented into areas where precise positioning is necessary. e.g. tool identification.
MDS D124
MDS D126
MDS D127
Application areas in factory automation (e.g. small paintshops to 180°C).
Compact and rugged ISO transponder; suitable for identification of transport units in production-related logistics; can also be deployed in harsh conditions.
Very compact data carrier that can be screwed into areas where precise positioning is necessary. e.g. tool identification.
MDS D139 1) Applications in production automation with high temperature demands (up to +220 °C).
Typical application areas:
• Paintshops and their preparatory treatments
• Primer coat, electrolytic dip area, cataphoresis with the associated drying furnaces
• Top coat area with drying furnaces
• Washing areas at temperatures > 85 °C
• Other applications with higher temperatures
MDS D160 2) Typical applications are, for example:
• Rented work clothing
• Hotel laundry
• Surgical textiles
• Hospital clothing
• Dirt collection mats
• Clothing for nursing homes/hostels
• Assembly lines with very small workpiece holders
MDS D165
MDS D200
MDS D261
MDS D324
MDS D339
Smart label (self-adhesive label)
From simple identification such as electronic barcode replacement/supplementation, through warehouse and distribution logistics, right up to product identification
From simple identification such as electronic barcode replacement/supplementation, through warehouse and distribution logistics, right up to product identification.
Smart label (self-adhesive label)
The design of the transponder (self-adhesive label) permits a variety of designs in order to ensure optimum dimensioning for the widest variety of applications.
From simple identification such as electronic barcode replacement/supplementation, through warehouse and distribution logistics, right up to product identification.
Production and distribution logistics as well as in assembly and production lines
Applications in production automation with high temperature demands (up to +220 °C).
For typical areas of application, see "MDS D139".
20
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
System overview
3.2 Overview of transponders
Transponder Area of application
MDS D400
MDS D421
MDS D422
MDS D423
MDS D424
MDS D425
MDS D426
Simple identification such as electronic barcode replacement/supplements, from warehouse and distribution logistics right through to product identification.
The MDS D421 is designed for tool coding according to DIN 69873.
It can be used wherever small data carriers and exact positioning are required, e.g. tool identification, workpiece holders
Identification of metallic workpiece holders, workpieces or containers
Identification of metallic workpiece holders, workpieces or containers, production automation
Production and distribution logistics as well as in assembly and production lines
Compact and rugged ISO transponder; suitable for screw mounting.
Use in assembly and production lines in the powertrain sector; ideal for mounting on motors, gearboxes, and workpiece holders
Compact and rugged ISO transponder; suitable for identification of transport units in production-related logistics; can also be deployed in harsh conditions
MDS D428
MDS D460
Compact and rugged ISO transponder; suitable for screw mounting
Use in assembly and production lines in the powertrain sector
Assembly lines with very small workpiece holders
1) Only with the MLFB 6GT2600-0AA10
2) Only with the MLFB 6GT2600-0AB10
Overview of the memory sizes of the ISO transponders for RF200
Transponder
MDS D1xx
MDS D2xx
MDS D3xx
MDS D4xx
Memory size
112 bytes of EEPROM
256 bytes of EEPROM
992 bytes of EEPROM
2000 bytes FRAM
See also
MOBY D System Manual
( http://support.automation.siemens.com/WW/view/en/13628689/0/en )
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 21
System overview
3.2 Overview of transponders
22
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
RF200 system planning
4.1
4.1.1
4.1.2
4
Fundamentals of application planning
Selection criteria for SIMATIC RF200 components
Assess your application according to the following criteria, in order to choose the right
SIMATIC RF200 components:
● Static or dynamic data transfer
● Data volume to be transferred
● Speed in case of dynamic transfer
● Ambient conditions such as relative humidity, temperature, chemical impacts, etc.
Transmission window and read/write distance
The reader generates an inductive alternating field. The field is strongest close to the reader; however, a read/write distance of "zero" between reader and transponder is not recommended.
The strength of the field decreases in proportion to the distance from the reader. The distribution of the field depends on the structure and geometry of the antennas in the reader and transponder
A prerequisite for the function of the transponder is a minimum field strength at the transponder, which is still barely achieved at distance S g
from the reader.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 23
RF200 system planning
4.1 Fundamentals of application planning
The picture below shows the transmission window of the SIMATIC RF210R and
SIMATIC RF220R readers between transponder and reader:
24
S a
Operating distance between transponder and reader
S g
Limit distance (maximum clear distance between upper surface of the reader and the transponder, at which the transmission can still function under normal conditions)
L Diameter of a transmission window
SP Intersection of the axes of symmetry of the transponder
Figure 4-1 RF210R/RF220R transmission window
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
RF200 system planning
4.1 Fundamentals of application planning
The figure below shows the transmission window of the SIMATIC RF240R and SIMATIC
RF260R readers between transponder and reader:
S a
Operating distance between transponder and reader
S g
Limit distance (maximum clear distance between upper surface of the reader and the transponder, at which the transmission can still function under normal conditions)
L Length of a transmission window
M Field centerpoint
Figure 4-2 RF240R/RF260R transmission window
The transponder can be used as soon as the intersection (SP) of the transponder enters the area of the transmission window.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 25
RF200 system planning
4.1 Fundamentals of application planning
From the diagrams above, it can also be seen that operation is possible within the area between S a
and S g
. The active operating area reduces as the distance increases, and shrinks to a single point at distance S g
. Only static mode should thus be used in the area between S a
and S g
.
4.1.3 Width of the transmission window
Determining the width of the transmission window
The following approximation formula can be used for practical applications:
B:
L:
Width of the transmission window
Length of the transmission window
Tracking tolerances
The width of the transmission window (B) is particularly important for the mechanical tracking tolerance. The formula for the dwell time is valid without restriction when B is observed.
26
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
RF200 system planning
4.1 Fundamentals of application planning
4.1.4 Permissible directions of motion of the transponder
Detection area and direction of motion of the transponder
The transponder and reader have no polarization axis, i.e. the transponder can come in from any direction, assume any position as parallel as possible to the reader, and cross the transmission window. The figure below shows the active area for various directions of transponder motion:
Transmission window
Direction of motion of the transponder
Detection area L x W
Figure 4-3 Detection areas of the reader for different directions of transponder motion
4.1.5 Operation in static and dynamic mode
Operation in static mode
If working in static mode, the transponder can be operated up to the limit distance (S g
). The transponder must then be positioned exactly over the reader:
Figure 4-4 Operation in static mode
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 27
RF200 system planning
4.1 Fundamentals of application planning
Note
Note that in a metallic environment the values for the limit distance are reduced.
Operation in dynamic mode
When working in dynamic mode, the transponder moves past the reader. The transponder can be used as soon as the intersection (SP) of the transponder enters the circle of the transmission window. In dynamic mode, the operating distance (S a
) is of primary importance.
[Operating distances, see Chapter Field data of transponders and readers (Page 35)]
4.1.6
28
Figure 4-5 Operation in dynamic mode
Dwell time of the transponder
The dwell time is the time in which the transponder remains within the transmission window of a reader. The reader can exchange data with the transponder during this time.
The dwell time is calculated thus: t
V
: Dwell time of the transponder
L: v
Tag
Length of the transmission window
: Speed of the transponder (tag) in dynamic mode
0,8: Constant factor used to compensate for temperature impacts and production tolerances
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
RF200 system planning
4.1 Fundamentals of application planning
The dwell time can be of any duration in static mode. The dwell time must be sufficiently long to allow communication with the transponder.
The dwell time is defined by the system environment in dynamic mode. The volume of data to be transferred must be matched to the dwell time or vice versa. In general: t
V:
: t
K
:
Dwell time of the data memory within the field of the reader
Communication time between transponder and communication module
4.1.7 Communication between communication module, reader and transponder
Communication between the communication module, reader and transponder takes place asynchronously through the RS422 interface. Depending on the communication module
(ASM) used, transfer rates of 19200 baud, 57600 baud or 115200 baud can be selected.
Calculation of the communication time for interference-free transfer
The communication time for fault-free data transfer is calculated as follows:
If the transmission is interrupted briefly due to external interference, the reader automatically continues the command.
Calculation of the maximum amount of user data
The maximum amount of user data is calculated as follows: t k
: t v
: n:
Communication time between communication module, reader and transponder
Dwell time
Amount of user data in bytes n max
: Max. amount of user data in bytes in dynamic mode t byte
: Transmission time for 1 byte
K : Constant; the constant is an internal system time. This contains the time for power buildup on the transponder and for command transfer
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 29
RF200 system planning
4.1 Fundamentals of application planning
Time constants K and t
byte
Table 4- 1 Typical communication time on the serial interface when operating with presence check
Transfer rate
[baud]
19200
57600
115200
MDS D1xx/D3xx
K
[ms]
41
28
26 t byte
[ms]
2.66
2.28
2.17
K
[ms]
50
33
31
Write
MDS D2xx t byte
[ms]
8.1
7.7
7.6
K
[ms]
35
34
26
Read
All MDS t byte
[ms]
1.08
0.59
0.56
MDS D4xx
K
[ms]
35
34
26 t byte
[ms]
1.08
0.59
0.56
Table 4- 2 Typical command duration on the air interface for operation without presence check
TAG type
All MDS
EEPROM (MDS D1xx/D3xx)
EEPROM (MDS D2xx)
FRAM (MDS D4xx)
Command
Read
Write
Write
Write
K [ms]
20
27
19
27
T byte
[ms]
0.55
2.2
7.5
0.55
In dynamic mode, the values for K and t byte
are independent of the transmission speed. The communication time only includes the processing time between the reader and the transponder and the internal system processing time of these components. The communication times between the communication module and the reader do not have to be taken into account because the command for reading or writing is already active when the transponder enters the transmission field of the reader.
The values shown above must be used when calculating the maximum quantity of user data in dynamic mode. They are applicable for both writing and reading.
30
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
RF200 system planning
4.1 Fundamentals of application planning
Calculation tool
User-friendly calculation tools are available for the communications modules ASM 456,
RF160C, RF170C and RF180C to calculate data transfer times. The calculation tools can be found on the DVD "RFID Systems Software & Documentation", order number 6GT2080-
2AA20.
Figure 4-6 Calculation tool interface
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 31
RF200 system planning
4.1 Fundamentals of application planning
4.1.8 Impact of secondary fields
Secondary fields in the range from 0 mm to 30% of the limit distance (S g
) generally always exist.
They should only be used during configuration in exceptional cases, however, since the read/write distances are very limited. Exact details of the secondary field geometry cannot be given, since these values depend heavily on the operating distance and the application.
When working in dynamic mode, remember that during the transition from the secondary field to the main field the presence of the tag is lost temporarily. It is therefore advisable to select a distance > 30% of S g
.
Figure 4-7 Gap in the field resulting from secondary fields
32
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
RF200 system planning
4.1 Fundamentals of application planning
Secondary fields without shielding
The following graphic shows typical primary and secondary fields, if no shielding measures are taken.
Figure 4-8 Secondary field without shielding
In this arrangement, the reader can also read tags via the secondary field. Shielding is required in order to prevent unwanted reading via the secondary field, as shown and described in the following.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 33
RF200 system planning
4.1 Fundamentals of application planning
Secondary fields with shielding
The following graphic shows typical primary and secondary fields, with metal shielding this time.
The metal shielding prevents the reader from detecting tags via the secondary field.
Figure 4-9 Secondary field with shielding
34
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
4.2
RF200 system planning
4.2 Field data of transponders and readers
Field data of transponders and readers
4.2.1 Field data
The limit distances (S g
) and operating distances (S a
) along with the length of the transmission window for each reader-transponder combination are listed in the tables below.
Table 4- 3 SIMATIC RF210R field data
MDS D124
MDS D127 1)
MDS D160
MDS D324
MDS D421
MDS D422
MDS D423
MDS D424
MDS D425
Length of the transmission window (L)
25
5
20
20
5
8
20
24
12
Operating distance (S
MDS D428
MDS D460
20
8
1) The transponder is only suitable for static mode.
1 ... 18
0 ... 2
1 ... 10
1 ... 8
0 ... 3
1 ... 9
2 ... 10
1 ... 16
1 ... 6
1 ... 10
1 … 8 a
)
All dimensions in mm.
Limit distance (S g
)
4
10
12
18
7
11
9
20
2
12
9
Table 4- 4 SIMATIC RF220R field data
MDS D124
MDS D126
MDS D160
MDS D324
MDS D422
MDS D423
MDS D424
MDS D425
MDS D426
MDS D428
MDS D460
All dimensions in mm.
Length of the transmission window (L)
35
45
20
30
18
30
30
20
40
25
25
Operating distance (S a
)
1 ... 28
2 ... 30
1 ... 20
2 ... 21
1 ... 12
2 ...24
2 ... 25
1 ... 11
2 ... 25
1 ... 18
1 ... 18
Limit distance (S g
)
14
28
29
13
30
21
20
31
35
22
25
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 35
RF200 system planning
4.2 Field data of transponders and readers
Table 4- 5 SIMATIC RF240R field data
MDS D100
MDS D124
MDS D126
MDS D160
MDS D165
MDS D200
MDS D261
MDS D324
MDS D400
MDS D422
MDS D423
MDS D424
MDS D425
MDS D426
MDS D428
MDS D460
All dimensions in mm.
Length of the transmission window (L)
100
65
80
50
105
90
70
55
95
25
40
75
30
65
50
50
Operating distance (S a
)
2 ... 84
2 ... 53
2 ... 57
1 ... 33
2 ... 80
2 ... 69
2 ... 60
1 ... 36
2 ... 80
1 ... 12
2 ... 35
1 ... 47
1 ... 15
2 ... 45
1 ... 30
1 ... 30
Table 4- 6 Field data SIMATIC RF250R, with ANT 8
Length of the transmission window (L)
MDS D117
MDS D127
MDS D421
All dimensions in mm.
2
3
3
Operating distance (S a
)
0 ... 2
0 ... 3
0 ... 3
Table 4- 7 Field data SIMATIC RF250R, with ANT 12
MDS D117
MDS D127
MDS D160
MDS D421
MDS D422
MDS D425
Length of the transmission window (L)
3
4
18
10
22
12
Operating distance (S
0 ... 3
0 ... 4
0 ... 12
0 ... 3
0 ... 7
0 ... 8 a
)
Limit distance (S g
)
3
4
4
Limit distance (S g
)
4
5
17
5
10
10
Limit distance (S g
)
94
78
70
40
95
60
65
37
90
15
40
53
17
55
34
34
36
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
RF200 system planning
4.2 Field data of transponders and readers
MDS D428
MDS D460
All dimensions in mm.
Length of the transmission window (L)
18
16
Operating distance (S a
)
1 ... 10
1 ... 10
Limit distance (S g
)
15
14
Table 4- 8 Field data SIMATIC RF250R, with ANT 18
Length of the transmission window (L)
MDS D124
MDS D160
MDS D324
MDS D421
MDS D422
MDS D423
MDS D424
MDS D425
MDS D428
MDS D460
All dimensions in mm.
26
22
30
16
24
21
26
19
19
19
Operating distance (S a
)
2 ... 24
1 ... 18
1 ... 18
0 ... 3
1 ... 8
1 ... 15
1 ... 27
1 ... 11
1 ... 8
1 ... 17
Limit distance (S g
)
18
36
16
15
21
37
26
27
4
14
Table 4- 9 Field data SIMATIC RF250R, with ANT 30
MDS D124
MDS D126
MDS D160
MDS D324
MDS D422
MDS D423
MDS D424
MDS D425
MDS D426
MDS D428
MDS D460
All dimensions in mm.
Length of the transmission window (L)
40
65
24
32
27
30
37
22
65
30
24
Operating distance (S a
)
1 ... 35
0 ... 47
1 ... 23
1 ... 22
0 ... 12
2 ... 18
0 ... 34
1 ... 12
0 ... 44
1 ... 20
1 ... 21
Limit distance (S g
)
48
60
30
35
15
26
48
20
58
32
27
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 37
RF200 system planning
4.2 Field data of transponders and readers
Table 4- 10 SIMATIC RF260R field data
MDS D100
MDS D124
MDS D126
MDS D139
MDS D160
MDS D165
MDS D200
MDS D261
MDS D324
MDS D339
MDS D400
MDS D423
MDS D424
MDS D426
MDS D428
MDS D460
All dimensions in mm.
Length of the transmission window (L)
120
80
110
120
60
120
120
80
80
110
140
55
80
75
50
50
Operating distance (S a
)
2 ... 110
2 ... 80
2 ... 75
2 ... 80
2 ... 40
2 ... 120
2 ... 100
2 ... 75
2 ... 60
2 ... 65
2 ... 110
2 ... 40
2 ... 60
2 ... 70
2 ... 40
2 ... 40
Table 4- 11 Filed data SIMATIC RF290R, with ANT D5
Length of the transmission window (L)
MDS D100
MDS D124
MDS D126
MDS D139
MDS D160
MDS D165
MDS D200
MDS D261
MDS D324
MDS D339
MDS D400
MDS D424
MDS D426
MDS D460
All dimensions in mm.
320
300
320
320
300
320
320
320
300
320
320
300
320
300
Operating distance (S a
)
0 ... 400
0 ... 200
0 ... 350
0 ... 400
0 ... 130
0 ... 350
0 ... 400
0 ... 300
0 ... 200
0 ... 300
0 ... 400
0 ... 200
0 ... 300
0 ... 120
Limit distance (S g
)
130
85
100
110
45
135
120
90
70
80
140
45
70
85
45
45
Limit distance (S g
)
500
280
400
500
180
450
500
400
280
380
500
280
350
160
38
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
RF200 system planning
4.2 Field data of transponders and readers
Table 4- 12 Field data SIMATIC RF290R, with ANT D6
Length of the transmission window (L)
MDS D100
MDS D124
MDS D126
MDS D139
MDS D160
MDS D165
MDS D200
MDS D261
MDS D324
MDS D339
MDS D400
MDS D424
MDS D426
All dimensions in mm.
X direction Y direction
520 420
500
520
520
500
400
420
420
400
520
520
520
500
520
520
500
520
420
420
420
400
420
420
400
420
Operating distance (S a
)
0 ... 550
0 ... 220
0 ... 400
0 ... 500
0 ... 130
0 ... 400
0 ... 500
0 ... 350
0 ... 200
0 ... 400
0 ... 500
0 ... 220
0 ... 350
Limit distance (S g
)
450
280
480
650
300
400
650
300
500
600
180
500
600
Table 4- 13 Field data SIMATIC RF290R, with ANT D10
Length of the transmission window (L)
MDS D100
MDS D124
MDS D126
MDS D139
X direction Y direction
1050 350
1000
1050
1050
1000
1050
300
350
350
300
350
MDS D160
MDS D165
MDS D200
MDS D261
MDS D324
1050
1050
1000
MDS D339
MDS D400
MDS D424
MDS D426
All dimensions in mm.
1050
1050
1000
1050
350
350
300
350
350
300
350
Operating distance (S a
)
0 ... 500
0 ... 200
0 ... 400
0 ... 450
0 ... 130
0 ... 350
0 ... 450
0 ... 350
0 ... 200
0 ... 300
0 ... 400
0 ... 200
0 ... 350
Limit distance (S g
)
600
280
500
550
180
450
550
450
280
380
500
280
400
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 39
RF200 system planning
4.2 Field data of transponders and readers
4.2.2 Minimum clearances
Minimum distance from transponder to transponder
The specified distances refer to a metal-free environment. For a metallic environment, the specified minimum distances must be multiplied by a factor of 1.5.
Table 4- 14 Minimum clearances for transponders
MDS D100
MDS D117
MDS D124
MDS D126
MDS D127
MDS D139
MDS D160
MDS D165
MDS D200
MDS D261
MDS D324
MDS D339
MDS D400
MDS D421
MDS D422
MDS D423
RF210R
-
≥ 15
≥ 25
-
≥ 15
-
≥ 20
-
-
-
≥ 25
-
-
≥ 10
≥ 15
-
RF220R
-
-
≥ 40
≥ 50
-
-
≥ 25
-
-
-
≥ 40
-
-
-
≥ 20
-
RF240R
-
-
≥ 90
≥ 100
-
-
≥ 70
-
-
-
≥ 90
-
-
-
≥ 50
≥ 80
RF260R
≥ 240
-
≥ 180
≥ 180
-
≥ 200
MDS D424
MDS D425
MDS D426
MDS D428
≥ 25
≥ 20
-
≥ 25
≥ 40
≥ 25
≥ 50
≥ 25
≥ 90
≥ 75
≥ 90
≥ 75
≥ 180
-
≥ 180
≥ 150
MDS D460 ≥ 20 ≥ 25 ≥ 70 ≥ 150
All values are in mm, relative to the operating distance (S a between transponder edge and transponder edge
) between reader and transponder, and
≥ 150
≥ 240
≥ 240
≥ 200
≥ 180
≥ 200
≥ 240
-
-
≥ 160
40
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
RF200 system planning
4.2 Field data of transponders and readers
Table 4- 15 Minimum clearances for transponders
RF250R 1) RF290R 2)
MDS D100
MDS D117
MDS D124
MDS D126
MDS D127
MDS D139
MDS D160
MDS D165
MDS D200
MDS D261
MDS D324
MDS D339
MDS D400
MDS D421
MDS D422
MDS D423
MDS D424
MDS D425
MDS D426
ANT 8 ANT 12 ANT 18 ANT 30 ANT D5 ANT D6 ANT D10
-
≥ 30
-
-
≥ 40
-
-
-
-
-
-
-
-
≥ 30
-
-
-
-
-
-
≥ 50
-
-
≥ 60
-
≥ 60
-
-
-
-
-
-
≥ 40
≥ 50
-
-
≥ 50
-
-
-
≥ 80
-
-
-
≥ 80
-
-
-
≥ 80
-
-
≥ 50
≥ 60
≥ 80
≥ 80
≥ 60
-
-
-
≥ 100
≥ 100
-
-
≥ 100
-
-
-
≥ 100
-
-
-
≥ 70
≥ 100
≥ 100
≥ 80
≥ 100
MDS D428
MDS D460
-
-
≥ 50
≥ 60
≥ 60
≥ 80
≥ 80
≥ 100
1) Depends on the connected antenna (ANT 8, 12, 18 or 30).
2) Depends on the connected antenna (ANT D5, D6 or D10).
≥ 1000
-
≥ 800
≥ 1000
-
≥ 1000
≥ 800
≥ 1000
≥ 1000
≥ 1000
≥ 800
≥ 1000
≥ 1000
-
-
-
≥ 800
-
≥ 800
-
≥ 800
≥ 1500
-
≥ 1200
≥ 1500
-
≥ 1500
≥ 1200
≥ 1500
≥ 1500
≥ 1500
≥ 1200
≥ 1500
≥ 1500
-
-
-
≥ 1200
-
≥ 1200
-
-
≥ 2000
-
≥ 1800
≥ 2000
-
≥ 2000
≥ 1800
≥ 2000
≥ 2000
≥ 2000
≥ 1800
≥ 2000
≥ 2000
-
-
-
≥ 1800
-
≥ 1800
-
-
All values are in mm, relative to the operating distance (S a
) between reader and transponder, and between transponder edge and transponder edge
Minimum distance from reader to reader
Table 4- 16 Minimum distances to readers or antennas
RF210R to
RF210R
RF220R to
RF220R
RF240R to
RF240R
≥ 60 mm ≥ 100 mm ≥ 120 mm
ANT x to ANT x with RF250R
ANT 8: ≥ 50 mm
ANT 12: ≥ 60 mm
ANT 18: ≥ 80 mm
ANT 30: ≥ 100 mm
All values are in mm
RF260R to
RF260R
≥ 150 mm
ANT Dx to ANT Dx with RF290R
ANT D5:
≥ 2000 mm
ANT D6:
≥ 2000 mm
ANT D10:
≥ 2000 mm
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 41
RF200 system planning
4.3 Installation guidelines
Note
Effect on inductive fields by not maintaining the minimum distances of the readers
If the values fall below those specified in the "Minimum distance from reader to reader" table, there is a risk of the function being affected by inductive fields. In this case, the data transfer time would increase unpredictably or a command would be aborted with an error.
Adherence to the values specified in the "Minimum distance from reader to reader" table is therefore essential.
If the specified minimum distance cannot be complied with due to the physical configuration, the SET-ANT command can be used to activate and deactivate the HF field of the reader.
The application software must be used to ensure that only one reader is active (antenna is switched on) at a time.
4.3
4.3.1
Installation guidelines
Overview
The transponder and reader complete with their antennas are inductive devices. Any type of metal in the vicinity of these devices affects their functionality. Some points need to be
considered during planning and installation if the values described in the "Field data
(Page 35)" section are to retain their validity:
● Minimum spacing between two readers or their antennas
● Minimum distance between two adjacent data memories
● Metal-free area for flush-mounting of readers or their antennas and transponders in metal
● Mounting of multiple readers or their antennas on metal frames or racks
The following sections describe the impact on the operation of the RFID system when mounted in the vicinity of metal.
42
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
4.3.2 Reduction of interference due to metal
Interference due to metal rack
RF200 system planning
4.3 Installation guidelines
Problem
A metal rack is located above the transmission window of the reader.
This affects the entire field. In particular, the transmission window between reader and transponder is reduced.
Remedy:
The transmission window is no longer affected if the transponder is mounted differently.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 43
RF200 system planning
4.3 Installation guidelines
Flush-mounting
Flush-mounting of transponders and readers Problem
Flush-mounting of transponders and readers is possible in principle.
However, the size of the transmission window is significantly reduced. The following measures can be used to counteract the reduction of the window:
Remedy:
Enlargement of the non-metallic spacer below the transponder and/or reader.
The transponder and/or reader are
10 to 20 mm higher than the metal surround.
(The value x ≥ 100 mm is valid, for example, for RF260R. It indicates that, for a distance x ≥ 100 mm, the reader can no longer be significantly affected by metal.)
Remedy:
Increase the non-metallic distance a, b.
The following rule of thumb can be used:
• Increase a, b by a factor of 2 to 3 over the values specified for metal-free areas
• Increasing a, b has a greater effect for readers or transponders with a large limit distance than for readers or transponders with a small limit distance.
44
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
RF200 system planning
4.3 Installation guidelines
Mounting of several readers on metal frames or racks
Any reader mounted on metal couples part of the field to the metal frame. There is normally no interaction as long as the minimum distance D and metal-free areas a, b are maintained.
However, interaction may take place if an iron frame is positioned unfavorably. Longer data transfer times or sporadic error messages at the communication module are the result.
Mounting of several readers on metal racks Problem: Interaction between readers
Remedy
Increase the distance D between the two readers.
Remedy
Introduce one or more iron struts in order to shortcircuit the stray fields.
Remedy
Insert a non-metallic spacer of 20 to 40 millimeter thickness between the reader and the iron frame. This will significantly reduce the induction of stray fields on the rack:
4.3.3 Effects of metal on different transponders and readers
Mounting different transponders and readers on metal or flush-mounting
Certain conditions have to be observed when mounting the transponders and readers on metal or flush-mounting. For more information, please refer to the descriptions of the individual transponders and readers in the relevant section.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 45
RF200 system planning
4.3 Installation guidelines
4.3.4 Impact of metal on the transmission window
In general, the following points should be considered when mounting RFID components:
● Direct mounting on metal is allowed only in the case of specially approved transponders.
● Flush-mounting of the components in metal reduces the field data; a test is recommended in critical applications.
● When working inside the transmission window, it should be ensured that no metal rail (or similar part) intersects the transmission field.
The metal rail would affect the field data.
The impact of metal on the field data (S g
, S a
, L) is shown in a table in this section. The values in the table describe the reduction of the field data in % with reference to non-metal
(100% means no impact).
46
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
4.3.4.1
RF200 system planning
4.3 Installation guidelines
RF210R
The RF210R can be flush-mounted in metal. Please allow for a possible reduction in the field data values.
The following table shows the different arrangements for the reader with and without a metallic environment:
Case Diagram a)
Description
Reader metal-free b) Reader on metal, distance from metal ≥ 12 mm c) d)
Reader in metal, flush against M18 nut
Reader in metal, all around
To avoid any influence on the field data, in Case d, the distance a should be ≥ 10 mm.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 47
RF200 system planning
4.3 Installation guidelines
Table 4- 17 Reduction of field data by metal: Transponder and RF210R
Transponder
MDS D124 1) metal-free on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm
MDS D127 metal-free on metal flush-mounted in metal
MDS D160 1) metal-free on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm
MDS D324 1) metal-free on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm
MDS D421 metal-free flush-mounted in metal
MDS D422 metal-free flush-mounted in metal
MDS D423 metal-free screwed onto metal flush-mounted in metal
MDS D424 1) metal-free on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm
MDS D425 metal-free screwed onto metal flush-mounted in metal; distance all round 25 mm
MDS D428 metal-free on metal flush-mounted in metal; distance all-round 25 mm
Reader without direct metal influence
(Case a, b and d)
100
90
85
100
100
100
100
100
90
80
100
75
100
90
100
180*
95
100
95
80
100
100
90
100
100
90
Reader flush-mounted in not intended use not intended use metal
(Case c)
82
90
80
75
95
95
95
90
90
90
90
50
80
40
90
130*
85
60
75
70
85
85
70
90
80
80
48
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
RF200 system planning
4.3 Installation guidelines
Transponder
MDS D460 1) metal-free on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm
Reader without direct metal influence
(Case a, b and d)
100
100
90
Reader flush-mounted in metal
(Case c)
90
90
90
1) Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is adequate clearance to the metal.
* Values of > 100 %, relative to non metal surroundings, can occur if transponders were developed specifically for mounting in/on metallic surroundings.
The values in the table describe the reduction of the field data. All values are percentages relative to non metal (100% means no influence).
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 49
RF200 system planning
4.3 Installation guidelines
4.3.4.2 RF220R
The RF220R can be flush-mounted in metal. Please allow for a possible reduction in the field data values.
The following table shows the different arrangements for the reader with and without a metallic environment:
Case Diagram a)
Description
Reader metal-free b) Reader on metal, distance from metal ≥ 12 mm c) d)
Reader in metal, flush against M30 nut
Reader in metal, all round
To avoid any influence on the field data, in Case d, the distance a should be ≥ 15 mm.
50
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
RF200 system planning
4.3 Installation guidelines
Table 4- 18 Reduction of field data by metal: Transponder and RF220R
Transponder
MDS D124
MDS D126
MDS D160
MDS D324
MDS D422
MDS D423
MDS D424
MDS D425
MDS D426
1)
1)
1)
1)
1)
1) metal-free on metal, distance 25 mm tag flush-mounted in metal; distance all round 25 mm metal-free on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm metal-free on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm metal-free on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm metal-free flush-mounted in metal metal-free screwed onto metal flush-mounted in metal metal-free on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm metal-free screwed onto metal flush-mounted in metal; distance all round 25 mm metal-free on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm
Reader without direct metal influence
(Case a, b and d)
100
97
86
100
85
80
100
100
100
100
97
93
100
85
100
150*
80
100
96
86
100
100
95
100
90
80
82
90
75
75
90
75
90
85
90
85
75
93
89
70
Reader flushmounted in metal
(Case c)
94
89
83
75
70
65
90
86
86
89
89
89
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 51
RF200 system planning
4.3 Installation guidelines
4.3.4.3
Transponder
MDS D428
MDS D460 1) metal-free on metal flush-mounted in metal; distance all round 25 mm metal-free on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm
Reader without direct metal influence
(Case a, b and d)
100
100
94
100
100
100
Reader flushmounted in metal
(Case c)
94
94
94
92
92
92
1) Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is adequate clearance to the metal.
* Values of > 100 %, relative to non metal surroundings, can occur if transponders were developed specifically for mounting in/on metallic surroundings.
The values in the table describe the reduction of the field data. All values are percentages relative to non metal (100% means no influence).
RF240R
The RF240R can be flush-mounted in metal. Please allow for a possible reduction in the field data values.
52
Figure 4-10 metal-free space RF240R
To avoid any impact on the field data, the distance a should be ≥ 20 mm.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
RF200 system planning
4.3 Installation guidelines
Table 4- 19 Reduction of field data by metal: Transponder and RF240R
Transponder
MDS D100
MDS D124
1)
1)
without metal on metal flush-mounted in metal
without metal on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm
MDS D126 1) without metal on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm
MDS D160 1) without metal on metal, distance 25 mm flush-mounted in metal
MDS D165 without metal on metal, distance 20 mm flush-mounted in metal; distance all round 20 mm
MDS D200 1) without metal on metal, distance 20 mm flush-mounted in metal, distance all round 20 mm
MDS D261 without metal on metal, distance 20 mm flush-mounted in metal, distance all round 20 mm
MDS D324 1) without metal on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm
MDS D400 1) without metal on metal, distance 20 mm flush-mounted in metal, distance all round 20 mm
MDS D422 without metal flush-mounted in metal
MDS D423 without metal on metal flush-mounted in metal; distance all round 10 mm
Reader without direct metal influence
100
95
90
100
90
85
100
80
70
100
90
100
75
70
100
95
70
100
85
80
100
95
90
100
80
75
100
90
100
185
Reader on metal
(metal plate)
95
90
75
85
80
70
80
75
55
90
85 not intended use
95
70
65
95
80
60
90
80
70
90
85
75
90
75
70
90
60 not intended use
90
75
Reader flushmounted in metal
(all round 20 mm)
80
75
70
75
75
65
70
60
55
80
80
75
65
60
85
70
50
90
70
65
80
80
70
80
55
50
85
40
85
70
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 53
RF200 system planning
4.3 Installation guidelines
Transponder
MDS D424 1) without metal on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm
MDS D425 without metal on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm
MDS D426 1) without metal on metal, distance 25 mm flush-mounted in metal; distance all-round 25 mm
MDS D428 without metal on metal flush-mounted in metal; distance all round 25 mm
MDS D460 1) without metal on metal, distance 25 mm flush-mounted in metal
Reader without direct metal influence
100
90
80
100
95
90
100
90
85
100
95
90
100
90
Reader on metal
(metal plate)
85
80
70
90
85
75
80
80
65
90
85
80
90
85 not intended use
Reader flushmounted in metal
(all round 20 mm)
80
75
65
85
80
70
70
70
60
85
83
70
80
80
1) Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is adequate clearance to the metal.
The values in the table describe the reduction of the field data. All values are percentages relative to non metal (100% means no influence).
54
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
4.3.4.4
RF200 system planning
4.3 Installation guidelines
RF250R
The RF250R reader is operated with the external antennas ANT 8, 12, 18 and 30. The antennas can be flush-mounted in metal. Please allow for a possible reduction in the field data values.
Figure 4-11 Metal-free space for ANT 8 / ANT 12 and ANT 18 / ANT 30
Table 4- 20 Reduction of field data by metal: Transponder and RF250R with ANT 8
Transponder RF250R with ANT 8
MDS D117
MDS D127 without metal flush-mounted in metal without metal flush-mounted in metal antenna without metal
100
65
100
70 antenna flushmounted in metal
85
55
85
60
MDS D421 without metal flush-mounted in metal
100
75
85
70
The values in the table describe the reduction of the field data. All values are percentages relative to non metal (100% means no influence).
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 55
RF200 system planning
4.3 Installation guidelines
Table 4- 21 Reduction of field data by metal: Transponder and RF250R with ANT 12
Transponder
MDS D117
MDS D127
MDS D160
MDS D421
MDS D422
MDS D425
MDS D428
MDS D460
1)
1) without metal flush-mounted in metal without metal flush-mounted in metal without metal on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm without metal flush-mounted in metal without metal flush-mounted in metal without metal screwed onto metal flush-mounted in metal; distance all round 25 mm without metal screwed onto metal flush-mounted in metal; distance all round 25 mm without metal on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm
100
50
100
65
100
90
80
65
90
95
90
85
RF250R with ANT 12 antenna without metal
100
100
100
115*
110*
100
110*
100 antenna flushmounted in metal
(all round 7 mm)
85
40
85
50
90
85
75
90
45
90
75
90
100
90
85
95
90
95
80
75
1) Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is adequate clearance to the metal.
* Values of > 100 %, relative to non metal surroundings, can occur if transponders were developed specifically for mounting in/on metallic surroundings.
The values in the table describe the reduction of the field data. All values are percentages relative to non metal (100% means no influence).
56
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
RF200 system planning
4.3 Installation guidelines
Table 4- 22 Reduction of field data by metal: Transponder and RF250R with ANT 18
Transponder
MDS D124
MDS D160
MDS D324
MDS D421
MDS D422
MDS D423
MDS D424
MDS D425
MDS D428
1)
1)
1)
1) without metal on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm without metal on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm without metal on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm without metal flush-mounted in metal without metal flush-mounted in metal without metal screwed onto metal flush-mounted in metal; without surround without metal on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm without metal screwed onto metal flush-mounted in metal; distance all round 25 mm without metal screwed onto metal flush-mounted in metal; distance all round 25 mm antenna without metal
100
100
95
100
100
90
100
100
95
95
95
RF250R with ANT 18
100
65
100
90
100
160*
95
100
100
100
100
100
100
100 antenna flushmounted in metal
(all round 10 mm)
80
80
70
90
90
80
80
80
75
85
50
100
90
85
120*
75
75
75
75
90
90
90
85
85
85
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 57
RF200 system planning
4.3 Installation guidelines
Transponder
MDS D460 1) without metal on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm
100
100
95
RF250R with ANT 18 antenna without metal antenna flushmounted in metal
(all round 10 mm)
85
85
80
1) Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is adequate clearance to the metal.
* Values of > 100 %, relative to non metal surroundings, can occur if transponders were developed specifically for mounting in/on metallic surroundings.
The values in the table describe the reduction of the field data. All values are percentages relative to non metal (100% means no influence).
Table 4- 23 Reduction of field data by metal: Transponder and RF250R with ANT 30
Transponder
MDS D124
MDS D126
MDS D160
MDS D324
MDS D422
MDS D423
1)
1)
1)
1) without metal on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm without metal on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm without metal on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm without metal on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm without metal flush-mounted in metal without metal screwed onto metal flush-mounted in metal; without surround
95
85
RF250R with ANT 30 antenna without metal
100
90
75
100
85
60
100
95
80
100
100
95
100
130*
80 antenna flushmounted in metal
(all round 20 mm)
80
75
70
80
75
50
85
80
70
80
75
70
95
80
90
110*
70
58
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
RF200 system planning
4.3 Installation guidelines
Transponder
MDS D424
MDS D425
MDS D426
MDS D428
MDS D460
1)
1)
1) without metal on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm without metal screwed onto metal flush-mounted in metal; distance all round 25 mm without metal on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm without metal screwed onto metal flush-mounted in metal; distance all round 25 mm without metal on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm
100
90
75
95
90
90
55
80
90
85
RF250R with ANT 30 antenna without metal
100
100
100
130*
100 antenna flushmounted in metal
(all round 20 mm)
85
75
70
90
75
70
70
65
45
90
110*
90
85
75
70
1) Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is adequate clearance to the metal.
* Values of > 100 %, relative to non metal surroundings, can occur if transponders were developed specifically for mounting in/on metallic surroundings.
The values in the table describe the reduction of the field data. All values are percentages relative to non metal (100% means no influence).
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 59
RF200 system planning
4.3 Installation guidelines
4.3.4.5 RF260R
The RF260R can be flush-mounted in metal. Please allow for a possible reduction in the field data values.
60
Figure 4-12 metal-free space for RF260R
To avoid any impact on the field data, the distance a should be ≥ 20 mm.
Table 4- 24 Reduction of field data by metal: Transponder and RF260R
Transponder
MDS D100 1) without metal on metal, distance 20 mm flush-mounted in metal; distance all round 20 mm
MDS D124 1) without metal on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm
MDS D126 1) without metal on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm
MDS D139 1) without metal on metal, distance 30 mm flush-mounted in metal
MDS D160 1) without metal on metal, distance 25 mm flush-mounted in metal
Reader without direct metal influence
100
70
65
100
95
78
100
75
55
100
95
100
90
Reader on metal
(metal plate)
85
65
50
93
85
75
85
68
53
90
90 not intended use
90
80 not intended use
Reader flushmounted in metal
(all round 20 mm)
65
50
40
75
70
65
73
60
40
75
75
75
80
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
RF200 system planning
4.3 Installation guidelines
Transponder
MDS D165 without metal on metal, distance 20 mm flush-mounted in metal; distance all round 20 mm
MDS D200 1) without metal on metal, distance 20 mm flush-mounted in metal, distance all round 20 mm
MDS D261 without metal on metal, distance 20 mm flush-mounted in metal; distance all round 20 mm
MDS D324 1) without metal on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm
MDS D339 1) without metal on metal, distance 30 mm flush-mounted in metal
MDS D400 1) without metal on metal, distance 20 mm flush-mounted in metal; distance all round 20 mm
MDS D423 without metal on metal flush-mounted in metal; distance all round 10 mm
MDS D424 1) without metal on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm
MDS D426 1) without metal on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm
MDS D428 without metal on metal flush-mounted in metal; distance all round 25 mm
Reader without direct metal influence
100
65
55
100
70
55
100
80
75
100
90
70
100
95
100
70
55
100
75
100
90
60
100
88
65
100
90
80
Reader on metal
(metal plate)
85
60
50
85
65
50
85
70
65
90
80
60
100
85
55
90
90
75
90
80
65
90
90 not intended use
85
65
50 not intended use
90
65
Reader flushmounted in metal
(all round 20 mm)
65
45
40
70
50
45
70
60
50
75
70
55
75
75
70
50
45
80
60
80
70
50
73
68
55
90
85
65
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 61
RF200 system planning
4.3 Installation guidelines
4.3.4.6
Transponder
MDS D460 1) without metal on metal, distance 25 mm flush-mounted in metal
Reader without direct metal influence
100
90
Reader on metal
(metal plate)
95
85 not intended use
Reader flushmounted in metal
(all round 20 mm)
90
80
1) Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is adequate clearance to the metal.
The values in the table describe the reduction of the field data. All values are percentages relative to non metal (100% means no influence).
RF290R
The RF290R reader is operated with the external antennas ANT D5, D6 and D10. The antennas can be flush-mounted in metal. Please allow for a possible reduction in the field data values.
Figure 4-13 Metal-free space for ANT D5
To avoid any influence on the field data, the distance a should be ≥ 150 or 200 mm.
62
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
RF200 system planning
4.3 Installation guidelines
Table 4- 25 Reduction of field data by metal: Transponder and RF290R with ANT D5
Transponder
MDS D100
MDS D124
MDS D126
MDS D139
MDS D160
MDS D165
MDS D200
MDS D261
MDS D324
MDS D339
1)
1)
1)
1)
1)
1)
1)
1) without metal on metal, distance 20 mm flush-mounted in metal; distance all round 20 mm without metal on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm without metal on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm without metal on metal, distance 30 mm flush-mounted in metal without metal on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm without metal on metal, distance 20 mm flush-mounted in metal; distance all round 20 mm without metal on metal, distance 20 mm flush-mounted in metal; distance all round 20 mm without metal on metal, distance 20 mm flush-mounted in metal; distance all round 20 mm without metal on metal, distance 25 mm flush-mounted in metal without metal on metal, distance 30 mm flush-mounted in metal
90
70
25
65
45
RF290R with ANT D5
Antenna on metal
(metal plate)
100
65
45
100
85
65
100
70
55
100
100
100
100
65
45
100
65
50
100
75
100
90 antenna flushmounted in metal
(all round 150 mm)
95
60
40 not intended use not intended use not intended use
95
80
60
95
65
50
95
85
95
65
20
95
60
40
95
60
40
95
60
45
95
70
95
85
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 63
RF200 system planning
4.3 Installation guidelines
Transponder
MDS D400
MDS D424
MDS D426
MDS D460
1)
1)
1)
1) without metal on metal, distance 20 mm flush-mounted in metal; distance all round 20 mm without metal on metal, distance 25 mm flush-mounted in metal without metal on metal, distance 25 mm flush-mounted in metal; distance all round 25 mm without metal on metal, distance 25 mm flush-mounted in metal
RF290R with ANT D5
Antenna on metal
(metal plate)
100
65
45
100
75
100
70
50
100
70 antenna flushmounted in metal
(all round 150 mm)
95
60
40 not intended use not intended use
95
70
95
65
45
95
65
1) Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is adequate clearance to the metal.
The values in the table describe the reduction of the field data. All values are percentages relative to non metal (100% means no influence).
Table 4- 26 Reduction of field data by metal: Transponder and RF290R with ANT D6
Transponder
MDS D100
MDS D124
MDS D126
MDS D139
MDS D160
MDS D165
MDS D200
1)
1)
1)
1)
1)
1) without metal on metal, distance 20 mm without metal on metal, distance 25 mm without metal on metal, distance 25 mm without metal on metal, distance 30 mm without metal on metal, distance 25 mm without metal on metal, distance 20 mm without metal on metal, distance 20 mm
65
100
80
100
60
100
50
100
65
100
65
100
80
100
RF290R with ANT D6
Antenna on metal
(metal plate) antenna flushmounted in metal
(all round 200 mm)
95
60
95
75
95
60
90
70
90
55
95
45
95
60
64
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
RF200 system planning
4.3 Installation guidelines
Transponder
MDS D261
MDS D324
MDS D339
MDS D400
MDS D424
MDS D426
1)
1)
1)
1)
1) without metal on metal, distance 20 mm without metal on metal, distance 25 mm without metal on metal, distance 30 mm without metal on metal, distance 20 mm without metal on metal, distance 25 mm without metal on metal, distance 25 mm
RF290R with ANT D6
Antenna on metal
(metal plate)
100
50
100
75
100
80
100
60
100
75
100
65 antenna flushmounted in metal
(all round 200 mm)
95
45
95
70
90
70
95
55
95
70
95
60
1) Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is adequate clearance to the metal.
The values in the table describe the reduction of the field data. All values are percentages relative to non metal (100% means no influence).
Table 4- 27 Reduction of field data by metal: Transponder and RF290R with ANT D10
Transponder
MDS D100
MDS D124
MDS D126
MDS D139
MDS D160
MDS D165
MDS D200
MDS D261
1)
1)
1)
1)
1)
1) without metal on metal, distance 20 mm without metal on metal, distance 25 mm without metal on metal, distance 25 mm without metal on metal, distance 30 mm without metal on metal, distance 25 mm without metal on metal, distance 20 mm without metal on metal, distance 20 mm without metal on metal, distance 20 mm
65
100
80
100
60
100
40
100
50
100
40
100
50
100
70
100
RF290R with ANT D10
Antenna on metal
(metal plate) antenna flushmounted in metal
(all round 200 mm)
95
40
90
60
95
60
90
70
90
55
90
30
95
40
90
30
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 65
RF200 system planning
4.3 Installation guidelines
Transponder
MDS D324
MDS D339
MDS D400
MDS D424
MDS D426
1)
1)
1)
1)
1) without metal on metal, distance 25 mm without metal on metal, distance 30 mm without metal on metal, distance 20 mm without metal on metal, distance 25 mm without metal on metal, distance 25 mm
RF290R with ANT D10
Antenna on metal
(metal plate)
100
70
100
80
100
50
100
70
100
70 antenna flushmounted in metal
(all round 200 mm)
90
60
90
70
95
40
90
60
95
65
1) Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is adequate clearance to the metal.
The values in the table describe the reduction of the field data. All values are percentages relative to non metal (100% means no influence).
4.3.5 Installation and connection of 2 to 6 antennas with one reader
If several antennas need to be operated on one reader, this can be achieved by using the antenna splitter or the antenna multiplexer RF260X.
Note that the antenna splitter is a purely passive device that splits the power at the input to two outputs and therefore halves it. This is possible both in PC mode (RS-232) and CM mode (RS-422). You can cascade the antenna splitters in such a way that up to 4 antennas can be connected at the same time.
The antenna multiplexer RF260X works only in PC mode (RS-232) in time division multiplex mode. This means that each antenna operates with full power for a certain time before the device moves on automatically to the next antenna. The antenna multiplexer normally operates in scan mode or buffered read mode which add the information about the antenna number to the reply of the transponder. With the antenna multiplexer, you can connect up to
6 antennas.
66
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
RF200 system planning
4.3 Installation guidelines
4.3.5.1 Installation options with the antenna splitter (2-4 antennas)
Possible configurations of the antennas
The antenna installations described here have been designed for reading smartlabels
(transponders) on goods on conveyor belts, conveyor systems or pallets.
A prerequisite is that there are no magnetically conducting materials (e.g. metal) in the vicinity of the antenna or the label.
Figure 4-14 Possible configuration of RF290R with ANT D5/D6/D10
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 67
RF200 system planning
4.3 Installation guidelines
Installation examples
Figure 4-15 Installation example with 2 ANT D6 (portal)
68
Figure 4-16 Installation example with ANT D6 (C arrangement)
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
RF200 system planning
4.3 Installation guidelines
Figure 4-17 Installation example with ANT D6 (tunnel)
Note
The minimum spacings between the antennas for operation with only one reader may be less than the distances described because this configuration has the same phase.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 69
RF200 system planning
4.3 Installation guidelines
4.3.5.2 Antenna installation
Configuring instructions
The antenna installation described below enables detection of transponders moving horizontally through the installation. Depending on the installation (antennas exactly opposite each other or offset in parallel), the label is aligned in parallel with the antennas or arbitrarily.
The size of the sensing range depends on the label alignment:
Note
Remember that the entire acquisition range of the antenna is larger than the transmission window in which the transponder is normally configured. This means there can be label alignments where even labels outside the transmission window will be identified. Labels aligned in parallel with the antennas, for example, can also be detected at larger distances beside or outside the antenna range.
For this reason, goods with labels must not be stored within a distance of up to 0.5 m from the installation. If this cannot be complied with, the antennas must be shielded.
To achieve three-dimensional detection of the labels in the sensing range, the following requirements must be met:
• The gate width must be less than or equal to 800 mm.
• The antenna size of the labels should be at least the size of an ISO card (85 mm x 54 mm).
• The distance from label to label must be greater than 100 mm. The distance from label to label can be reduced if the gate width is correspondingly reduced. This applies especially for distances under 50 mm.
• There should be no more than 16 labels within the sensing range of the antennas at the same time.
The number of labels can be increased if the gate width is correspondingly reduced and the maximum speed suitably adapted.
• The maximum speed of the labels must not exceed 1 m/s. (This depends on the number and alignment of the labels, the number of data blocks to be processed, the data protocol required and the label type).
• To the front and sides of the antenna, there must be a distance of more than 150 mm to metal parts.
• There must be no interference to the write/read device from other electrical equipment in the surrounding area.
Note
The RF290R reader is not capable of multitag operation in the CM mode.
70
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
RF200 system planning
4.3 Installation guidelines
Required components
For installation with
● 2 antennas (gate)
● 3 antennas (C arrangement)
● 4 antennas (tunnel) the following components are required:
Table 4- 28 Components required for setting up with 2, 3 or 4 antennas
Number for installation with
2 ant. 3 ant. 4 ant.
1 1 1
Component
Basic device:
RF290R (↔ CM or PC)
2
2
1
1
1
1
3
3
2
1
1
1
4
4
3
1
1
1
Antenna ANT D5 / D6 / D10
With ANT D6 if required: cover
Antenna splitter
MOBY wide-range power supply unit for SIMATIC RF systems
(for PC mode only)
24 V connecting cable, length 5 m
(for PC mode only)
Connecting cable:
RF290R ↔ PC or
RF290R ↔ CM
Order number
RF290R: 6GT2821-0AC12 optionally:
ASM 475: 6GT2002-0GA10
ASM 456: 6GT2002-0ED00
RF170C: 6GT2002-0HD00
RF180C: 6GT2002-0JD00
RF182C: 6GT2002-0JD10 optionally:
ANT D5: 6GT2698-5AA10
ANT D6: 6GT2698-5AB00
ANT D10: 6GT2698-5AF00
6GT2698-5AD00
6GT2603-0AC00
EU: 6GT2898-0AA00
UK: 6GT2898-0AA10
US: 6GT2898-0AA20
6GT2491-1HH50
6GT2891-4KH ... optionally:
6GT2891-4F ...
6GT2891-4EH ...
Installation information
The cables on the antennas and the antenna splitter are 3.3 m or 10.5 m long. The write/read device must be installed in the vicinity of the antennas. If there are greater distances between the write/read device and the antennas, the antenna cable can be increased by 7.2 m with the extension (6GT2 691-0DH72). This results in shorter ranges.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 71
RF200 system planning
4.3 Installation guidelines
Metal-free space
To guarantee perfect functioning of the individual installation versions, all larger metal parts in the vicinity of the antennas must be removed.
Figure 4-18 Metal-free space, side view (based on the example of a tunnel arrangement on a conveyor belt) a b c approx. half antenna length min. 100 mm max. 600 mm
Metal-free space
Figure 4-19 Metal-free space, view from above (based on the example of a tunnel arrangement on a conveyor belt)
Metal in the vicinity of the antennas
If metal in the vicinity of the antennas cannot be avoided, the following must be noted:
● There must be a minimum allround gap of 100 mm between the antenna and metal.
Serious loss of sensing range must be expected above 50 mm. There is no discernible influence at distances greater than 150 mm from the metal.
● The influence of the metal depends heavily on its size and shape. Thin metal rods have less influence on the magnetic field than large surfaces.
● Larger metal surfaces (edge length > 50 mm) in parallel with the antennas or labels result in a short-circuit of the magnetic lines of force. As a result, the labels cannot be read.
● Metal parts under the conveyor belt change the direction of the magnetic lines of force.
Serious loss of sensing range must be expected as a result. Horizontally aligned labels cannot be read in such cases.
● The metal parts must not form closed loops or circuits. If necessary, these must be electrically interrupted at one point.
72
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
RF200 system planning
4.3 Installation guidelines
● The metal parts in the immediate vicinity of the antenna must be grounded in a mesh with a good HF connection.
● Since the write/read device is installed in a metal housing, and the antennas can couple into the cables to the write/read device, it must be installed at a distance of at least 500 mm from the antennas.
Notes on installing and laying the antenna cable
To suppress possible interference, an EMC hinged ferrite choke must be fitted to the antenna cables (as well as the antenna cable between the reader and the antenna splitter).
The coaxial cable must be wound tightly at least four times through the EMC ring core. The maximum distance between the connecting plug for the reader or the antenna splitter and the ring core must be 100 mm.
The antenna cable must always be run vertically from the antennas. A minimum distance of
200 mm to the antennas must be observed as the cables continue. Otherwise, performance losses must be expected.
There must be a distance of at least 300 mm between antenna cables and parallel power cables.
Unrequired cable length must be secured in a bundle with a diameter of 100 to 150 mm.
If the standard antenna cable is too short, it can be increased by 7.20 m with the extension.
Slight range losses must be expected here.
To achieve optimal read ranges, the antenna cable should not be shortened or lengthened.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 73
RF200 system planning
4.4 Further information
4.3.5.3 Installation options with the antenna multiplexer (2-6 antennas)
You can operate up to six antennas on one reader via the multiplexer.
The data is processed sequentially.
Antenna switchover is performed in time-multiplex mode, so by connecting several antennas together, the processing time / activation time per antenna is lengthened accordingly.
4.4
Figure 4-20 Configuration example of the antenna multiplexer with ANT D5
Further information
Further information on "Fundamentals of application planning" and "EMC" can be found in
RF300 system manual ( http://support.automation.siemens.com/WW/view/en/18722182 ).
74
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Readers
NOTICE
Pulling and plugging readers
Pull or plug the reader only when the power supply is turned off
If this is not observed, under certain conditions, the reader will not start up correctly and communication with a transponder will not be possible.
Note
IO-Link variants of the RF200 readers
The IO-Link variants of the readers are not included in the system manual. You will find these in the "SIMATIC RF200 IO-Link
( http://support.automation.siemens.com/WW/view/en/60641859 )" operating instructions.
5
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 75
Readers
5.1 SIMATIC RF210R
5.1 SIMATIC RF210R
5.1.1 Features
SIMATIC RF210R Characteristics
Field of application Identification tasks on assembly lines in harsh industrial environments
Design ① RS422 interface
②
Status display
5.1.2 RF210R ordering data
RF210R with RS422 interface (3964R)
Article number
6GT2821-1AC10
76
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
5.1.3
5.1.4
Readers
5.1 SIMATIC RF210R
Pin assignment RF210R with RS422 interface
Pin Assignment Pin
Device end
8-pin M12
7
8
5
6
1
2
3
4
+ 24 V
- Transmit
0 V
+ Transmit
+ Receive
- Receive
Unassigned
Ground (shield)
Display elements of the RF210R reader
Color green flashing permanently lit yellow 1) flashing red
Meaning
Operating voltage present, reader not initialized or antenna switched off
Operating voltage present, reader initialized and antenna switched on
Transponder present
Error has occurred, the type of flashing corresponds to the error code in the table in the section "Error codes". The optical error display is only reset if the corresponding reset parameter ("option_1 = 2") is set (see Product information "SIMATIC RF200 command set"
( http://support.automation.siemens.com/WW/view/en/44864850 )).
1) Only in the "with presence" mode.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 77
Readers
5.1 SIMATIC RF210R
5.1.5 Minimum distance between RF210R readers
RF210R side by side
D ≥ 60 mm
Figure 5-1 Minimum distance between RF210R readers
RF210R face to face
D ≥ 100 mm
Figure 5-2 Face-to-face distance between two RF210Rs
78
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
5.1.6
Readers
5.1 SIMATIC RF210R
Technical specifications of the RF210R reader
Product type designation
Inductive interface to the transponder
Transmission frequency for power/data
Antenna
Interface to the communications module
Baud rate
Cable length reader ↔ communications module
Read/write distances of reader
Maximum data transmission rate reader ↔ transponder (tag)
• Read
• Write
Power supply
Display elements
Plug connector
Housing
• Dimensions (L × ∅)
• Color
• Material
Securing
Ambient temperature
• During operation
• During transportation and storage
Degree of protection to EN 60529
Shock to EN 60721-3-7 Class 7 M2
Vibration to EN 60721-3-7 Class 7 M2
Weight
Approvals
Current consumption
RF210R
13.56 MHz integrated
6GT2821-1AC10
RS-422 (3964R protocol)
19200, 57600, 115200 baud max. 1000 m
(shielded cable)
Refer to chapter Field data (Page 35)
• approx. 1.5 KBps
• approx. 1.5 KBps
24 VDC
3-color LED
(operating voltage, presence, error)
M12 (8-pin)
• 83 × 18 mm (incl. 8-pin connector sleeve and plastic cap)
• Silver
• Brass, nickel-plated
2 metal M18 × 1 hexagonal nuts;
Thickness: 4 mm, tightening torque ≤ 20 Nm
• -20 °C ... +70 °C
• -25 °C ... +80 °C
IP67
50 g
20 g approx. 65 g (incl. two M18 nuts)
Radio to R&TTE guidelines EN 300 330,
EN 301489, CE, FCC, UL/CSA typ. 50 mA
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 79
Readers
5.1 SIMATIC RF210R
5.1.7 Approvals
FCC information
Siemens SIMATIC RF210R (MLFB 6GT2821-1AC10) FCC ID NXW-RF210R
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Caution
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Note
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
IC information
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d`Industrie Canada applicables aux appareils radio exempts de licence. L`exploitation est autorisée aux deux conditions suivantes :
(1) L`appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l`appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d`en compromettre le fonctionnement.
80
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
5.1.8 Dimension drawing
Figure 5-3 RF210R dimension drawing
Dimensions in mm
Readers
5.1 SIMATIC RF210R
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 81
Readers
5.2 SIMATIC RF220R
5.2 SIMATIC RF220R
5.2.1 Features
SIMATIC RF220R Characteristics
Field of application
Design
Identification tasks on assembly lines in harsh industrial environments
① RS422 interface
②
Status display
5.2.2 RF220R ordering data
RF220R with RS-422 interface (3964R)
Article number
6GT2821-2AC10
82
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
5.2.3
5.2.4
Readers
5.2 SIMATIC RF220R
RF220R pin assignment with RS422 interface
Pin Assignment Pin
Device end 8pin M12
7
8
5
6
1
2
3
4
+ 24 V
- Transmit
0 V
+ Transmit
+ Receive
- Receive
Unassigned
Ground (shield)
Display elements of the RF220R reader
Color green flashing permanently lit yellow 1) flashing red
Meaning
Operating voltage present, reader not initialized or antenna switched off
Operating voltage present, reader initialized and antenna switched on
Transponder present
Error has occurred, the type of flashing corresponds to the error code in the table in the section "Error codes". The optical error display is only reset if the corresponding reset parameter ("option_1 = 2") is set (see Product information "SIMATIC RF200 command set"
( http://support.automation.siemens.com/WW/view/en/44864850 )).
1) Only in the "with presence" mode.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 83
Readers
5.2 SIMATIC RF220R
5.2.5 Minimum distance between RF220R readers
RF220R side by side
D ≥ 100 mm
Figure 5-4 Minimum distance between RF220R readers
RF220R face to face
D ≥ 150 mm
Figure 5-5 Face-to-face distance between two RF220Rs
84
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
5.2.6
Readers
5.2 SIMATIC RF220R
Technical specifications of the RF220R reader
Product type designation
Inductive interface to the transponder
Transmission frequency for power/data
Antenna
Interface to the communications module
Baud rate
Cable length reader ↔ communications module
Read/write distances of reader
Maximum data transmission rate reader ↔ transponder (tag)
• Read
• Write
Power supply
Display elements
Plug connector
Housing
• Dimensions (L × ∅)
• Color
• Material
Securing
Ambient temperature
• During operation
• During transportation and storage
Degree of protection to EN 60529
Shock to EN 60721-3-7 Class 7 M2
Vibration to EN 60721-3-7 Class 7 M2
Weight
Approvals
Current consumption
RF220R
13.56 MHz integrated
6GT2821-2AC10
RS-422 (3964R protocol)
19200, 57600, 115200 baud max. 1000 m
(shielded cable)
Refer to chapter Field data (Page 35)
• approx. 1.5 KBps
• approx. 1.5 KBps
24 VDC
3-color LED
(operating voltage, presence, error)
M12 (8-pin)
• 83 × 30 mm (incl. 8-pin connector sleeve and plastic cap)
• Silver
• Brass, nickel-plated
2 metal M30 × 1.5 hexagonal nuts;
Thickness: 5 mm, tightening torque ≤ 40 Nm
• -20 °C ... +70 °C
• -25 °C ... +80 °C
IP67
50 g
20 g approx. 140 g (incl. two M30 nuts)
Radio to R&TTE guidelines EN 300 330,
EN 301489, CE, FCC, UL/CSA typ. 50 mA
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 85
Readers
5.2 SIMATIC RF220R
5.2.7 Approvals
FCC information
Siemens SIMATIC RF220R (MLFB 6GT2821-2AC10) FCC ID NXW-RF220R
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Caution
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Note
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
IC information
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d`Industrie Canada applicables aux appareils radio exempts de licence. L`exploitation est autorisée aux deux conditions suivantes :
(1) L`appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l`appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d`en compromettre le fonctionnement.
86
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
5.2.8 Dimension drawing
Figure 5-6 RF220R dimension drawing
Dimensions in mm
Readers
5.2 SIMATIC RF220R
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 87
Readers
5.3 SIMATIC RF240R
5.3 SIMATIC RF240R
5.3.1 Features
SIMATIC RF240R Characteristics
Field of application
Design
Identification tasks on assembly lines in harsh industrial environments
① Depending on the device variant:
:RS-422 or RS-232 interface
②
Status indicator
5.3.2 RF240R ordering data
RF240R with RS-422 interface (3964R)
RF240R with RS-232 interface (3964R)
RF240R with RS-232 interface (ASCII)
Article number
6GT2821-4AC10
6GT2821-4AC11
6GT2821-4AC40
88
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
5.3.3
5.3.4
Readers
5.3 SIMATIC RF240R
Pin assignment RF240R
Pin Pin
Device end 8pin M12
7
8
5
6
1
2
3
4
RS-422
+24 V
- Transmit
0 V
+ Transmit
+ Receive
- Receive
Unassigned
Ground (shield)
Interface assignment
RS-232
+24 V
RXD
0 V
TXD
Unassigned
Unassigned
Unassigned
Ground (shield)
Display elements of the RF240R reader
Color green flashing permanently lit yellow 1) flashing red
Meaning
Operating voltage present, reader not initialized or antenna switched off
Operating voltage present, reader initialized and antenna switched on
Transponder present
Error has occurred, the type of flashing corresponds to the error code in the table in the section "Error codes". The optical error display is only reset if the corresponding reset parameter ("option_1 = 2") is set (see Product information "SIMATIC RF200 command set"
( http://support.automation.siemens.com/WW/view/en/44864850 )).
1) Only in the "with presence" mode.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 89
Readers
5.3 SIMATIC RF240R
5.3.5 Minimum distance between several RF240R readers
RF240R readers side by side
D ≥ 120 mm (with 2 readers)
D ≥ 200 mm (with more than 2 readers)
Figure 5-7 Minimum distance between several RF240R readers
RF240R face-to-face
D ≥ 400 mm
Figure 5-8 Face-of-face distance between two RF240R readers
90
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
5.3.6
Readers
5.3 SIMATIC RF240R
Technical specifications of the RF240R reader
Product type designation
Inductive interface to the transponder
Transmission frequency for power/data
Antenna
Interface
• Communications module
• PC
Baud rate
Cable length reader ↔ communications module
Read/write distances of reader
Maximum data transmission rate reader ↔ transponder (tag)
• Read
• Write
Power supply
Display elements
Plug connector
Housing
• Dimensions (L × W × H)
• Color
• Material
Securing
Ambient temperature
• During operation
• During transportation and storage
Degree of protection to EN 60529
Shock to EN 60721-3-7 Class 7 M2
Vibration to EN 60721-3-7 Class 7 M2
Weight
Approvals
Current consumption
6GT2821-4AC10
6GT2821-4AC11
6GT2821-4AC40
RF240R
13.56 MHz integrated
• RS-422 (3964R protocol)
• RS-232 (3964R or ASCII protocol)
19200, 57600, 115200 baud
RS-422: max. 1000 m
RS-232: Max. 30 m
(shielded cable)
Refer to chapter Field data (Page 35)
• approx. 1.5 KBps
• approx. 1.5 KBps
24 VDC
3-color LED
(operating voltage, presence, error)
M12 (8-pin)
• 50 × 50 × 30 mm (without M12 device connector)
• Anthracite
• Plastic PA 6.6
2 x M5 screws
Tightening torque ≤ 1.5 Nm
• -20 °C ... +70 °C
• -25 °C ... +80 °C
IP67
50 g
20 g
Approx. 60 g
Radio to R&TTE guidelines EN 300 330,
EN 301489, CE, FCC, UL/CSA typ. 25 mA
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 91
Readers
5.3 SIMATIC RF240R
5.3.7 Approvals
FCC information
Siemens SIMATIC RF240R (MLFB 6GT2821-4AC10) FCC ID NXW-RF240R
Siemens SIMATIC RF240R (MLFB 6GT2821-4AC11) FCC ID NXW-RF240R
Siemens SIMATIC RF240R (MLFB 6GT2821-4AC40) FCC ID NXW-RF240R
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Caution
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Note
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
IC information
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d`Industrie Canada applicables aux appareils radio exempts de licence. L`exploitation est autorisée aux deux conditions suivantes :
(1) L`appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l`appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d`en compromettre le fonctionnement.
92
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
5.3.8 Dimension drawing
Figure 5-9 Dimension drawing RF240R
Dimensions in mm
Readers
5.3 SIMATIC RF240R
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 93
Readers
5.4 SIMATIC RF250R
5.4 SIMATIC RF250R
5.4.1 Features
SIMATIC RF250R Characteristics
Area of application
Design
Identification tasks on assembly lines in harsh industrial environments
① Depending on the device variant:
②
Status indicator
③
Antenna connector, M8
5.4.2
Note
Reader requires external antennas
Note that the RF250R reader is designed only for operation with external antennas and can only be operated in conjunction with the antennas ANT 8, ANT 12, ANT 18 or ANT 30.
Ordering data RF250R
RF250R with RS-422 interface (3964R)
RF250R with RS-232 interface (ASCII)
Article number
6GT2821-5AC10
6GT2821-5AC40
94
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
5.4.3
5.4.4
Readers
5.4 SIMATIC RF250R
Pin assignment RF250R
Pin Pin
Device end 8pin M12
7
8
5
6
1
2
3
4
RS-422
+24 V
- Transmit
0 V
+ Transmit
+ Receive
- Receive
Unassigned
Ground (shield)
Interface assignment
RS-232
+24 V
RXD
0 V
TXD
Unassigned
Unassigned
Unassigned
Ground (shield)
Display elements of the RF250R reader
Color green flashing permanently lit yellow 1) flashing red
Meaning
Operating voltage present, reader not initialized or antenna switched off
Operating voltage present, reader initialized and antenna switched on
Transponder present
Error has occurred, the type of flashing corresponds to the error code in the table in the section "Error codes". The optical error display is only reset if the corresponding reset parameter ("option_1 = 2") is set (see Product information "SIMATIC RF200 command set"
( http://support.automation.siemens.com/WW/view/en/44864850 )).
1) Only in the "with presence" mode.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 95
Readers
5.4 SIMATIC RF250R
5.4.5 Technical specifications of the RF250R reader
Product type designation
Inductive interface to the transponder
Transmission frequency for power/data
Connectable antennas
Interface
• Communications module
• PC
Baud rate
Cable length reader ↔ communications module
Transmit power
Read/write distances of reader
Maximum data transmission rate reader ↔ transponder (tag)
• Read
• Write
Power supply
Display elements
Connection
• Power supply/data line
• Antenna
Housing
• Dimensions (L × W × H)
• Color
• Material
Securing
Ambient temperature
• During operation
• During transportation and storage
Degree of protection to EN 60529
Shock to EN 60721-3-7 Class 7 M2
Vibration to EN 60721-3-7 Class 7 M2
Weight
6GT2821-5AC10
6GT2821-5AC40
RF250R
13.56 MHz
ANT 8, ANT 12, ANT 18, ANT 30
• RS-422 (3964R protocol)
• RS-232 (ASCII protocol)
19200, 57600, 115200 baud
RS-422: max. 1000 m
RS-232: Max. 30 m
(shielded cable)
180 mW (50 ohms)
Refer to chapter Field data (Page 35)
• approx. 1.5 KBps
• approx. 1.5 KBps
24 VDC
3-color LED
(operating voltage, presence, error)
• M12, 8-pin, male
• M8, 4-pin, female
• 50 × 50 × 30 mm (without M12 device connector)
• Anthracite
• Plastic PA 6.6
2 x M5 screws
Tightening torque ≤ 1.5 Nm
• -20 °C ... +70 °C
• -25 °C ... +80 °C
IP67
50 g
20 g
Approx. 60 g
96
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Approvals
Current consumption
Readers
5.4 SIMATIC RF250R
6GT2821-5AC10
6GT2821-5AC40
Radio to R&TTE guidelines EN 300 330,
EN 301489, CE, FCC, UL/CSA typ. 35 mA
5.4.6 Approvals
FCC information
Siemens SIMATIC RF250R (MLFB 6GT2821-5AC10) FCC ID NXW-RF250R
Siemens SIMATIC RF250R (MLFB 6GT2821-5AC40) FCC ID NXW-RF250R
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Caution
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Note
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
IC information
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 97
Readers
5.4 SIMATIC RF250R
Le présent appareil est conforme aux CNR d`Industrie Canada applicables aux appareils radio exempts de licence. L`exploitation est autorisée aux deux conditions suivantes :
(1) L`appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l`appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d`en compromettre le fonctionnement.
If the antenna is detachable, require the following two conditions:
(1) To reduce potential radio interference to other users, the antenna type should be chosen that the radiated power is not more than that permitted for successful communication.
(2) This device has been designed to operate with the antennas listed below. Antennas not included in this list are strictly prohibited for use with this device. The required antenna impedance is 50 Ω.
Si l'antenne est amovible, demandez les deux conditions suivantes :
(1) Afin de réduire le risque d'interférence aux autres utilisateurs, il faut choisir le type d'antenne et son gain de façon à ce que la puissance rayonnée ne soit pas supérieure au niveau requis pour l'obtention d'une communication satisfaisante.
(2) Ce dispositif a été conçu pour fonctionner avec les antennes énumérées ci-dessous. Les antennes non incluses dans cette liste sont strictement interdites pour l'exploitation de ce dispositif. L'impédance d'antenne requise est 50 Ω.
5.4.7 Dimension drawing
98
Figure 5-10 Dimension drawing RF250R
Dimensions in mm
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
5.5 SIMATIC RF260R
5.5.1 Features
SIMATIC RF260R Characteristics
Field of application
Design
Readers
5.5 SIMATIC RF260R
Identification tasks on assembly lines in harsh industrial environments
① Depending on the device variant:
RS-422 or RS-232 interface
②
Status indicator
5.5.2 Ordering data for RF260R
RF260R with RS-422 interface (3964R)
RF260R with RS-232 interface (3964R)
RF260R with RS-232 interface (ASCII)
Article number
6GT2821-6AC10
6GT2821-6AC11
6GT2821-6AC40
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 99
Readers
5.5 SIMATIC RF260R
5.5.3 Pin assignment RF260R
Pin Pin
Device end 8pin M12
7
8
5
6
1
2
3
4
RS-422
+24 V
- Transmit
0 V
+ Transmit
+ Receive
- Receive
Unassigned
Ground (shield)
Interface assignment
RS-232
+24 V
RXD
0 V
TXD
Unassigned
Unassigned
Unassigned
Ground (shield)
5.5.4 Display elements of the RF260R reader
Color green flashing permanently lit yellow 1) flashing red
Meaning
Operating voltage present, reader not initialized or antenna switched off
Operating voltage present, reader initialized and antenna switched on
Transponder present
Error has occurred, the type of flashing corresponds to the error code in the table in the section "Error codes". The optical error display is only reset if the corresponding reset parameter ("option_1 = 2") is set (see Product information "SIMATIC RF200 command set"
( http://support.automation.siemens.com/WW/view/en/44864850 )).
1) Only in the "with presence" mode.
100
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
5.5.5 Minimum distance between several RF260R
RF260R side by side
Readers
5.5 SIMATIC RF260R
D ≥ 150 mm (with 2 readers)
D ≥ 250 mm (with more than 2 readers)
Figure 5-11 Minimum distance between several RF260R
RF260R face to face
D ≥ 500 mm
Figure 5-12 Face-to-face distance between two RF260R
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 101
Readers
5.5 SIMATIC RF260R
5.5.6 Technical data of the RF260R reader
Product type designation
Inductive interface to the transponder
Transmission frequency for power/data
Antenna
Interface
• Communications module
• PC
Baud rate
Cable length reader ↔ communications module
Read/write distances of reader
Maximum data transmission rate reader ↔ transponder (tag)
• Read
• Write
Power supply
Display elements
Plug connector
Housing
• Dimensions (L × W × H)
• Color
• Material
Securing
Ambient temperature
• During operation
• During transportation and storage
Degree of protection to EN 60529
Shock to EN 60721-3-7 Class 7 M2
Vibration to EN 60721-3-7 Class 7 M2
Weight
Approvals
Current consumption
6GT2821-6AC10
6GT2821-6AC11
6GT2821-6AC40
RF260R
13.56 MHz integrated
• RS-422 (3964R protocol)
• RS-232 (3964R or ASCII protocol)
19200, 57600, 115200 baud
RS-422: max. 1000 m
RS-232: Max. 30 m
(shielded cable)
Refer to chapter Field data (Page 35)
• approx. 1.5 KBps
• approx. 1.5 KBps
24 VDC
3-color LED
(operating voltage, presence, error)
M12 (8-pin)
• 75 × 75 × 41 mm (without M12 device connector)
• Anthracite
• Plastic PA 6.6
2 x M5 screws
Tightening torque ≤ 1.5 Nm
• -20 °C ... +70 °C
• -25 °C ... +80 °C
IP67
50 g
20 g
Approx. 200 g
Radio to R&TTE guidelines EN 300 330,
EN 301489, CE, FCC, UL/CSA typ. 50 mA
102
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Readers
5.5 SIMATIC RF260R
5.5.7 Approvals
FCC information
Siemens SIMATIC RF260R (MLFB 6GT2821-6AC10) FCC ID NXW-RF260R
Siemens SIMATIC RF260R (MLFB 6GT2821-6AC11) FCC ID NXW-RF260R
Siemens SIMATIC RF260R (MLFB 6GT2821-6AC40) FCC ID NXW-RF260R
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Caution
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Note
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
IC information
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d`Industrie Canada applicables aux appareils radio exempts de licence. L`exploitation est autorisée aux deux conditions suivantes :
(1) L`appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l`appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d`en compromettre le fonctionnement.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 103
Readers
5.5 SIMATIC RF260R
5.5.8 Dimension drawing
Figure 5-13 Dimension drawing RF260R
Dimensions in mm
104
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
5.6 SIMATIC RF290R
Readers
5.6 SIMATIC RF290R
5.6.1 Features
SIMATIC RF290R Characteristics
Area of application
Design
Identification tasks in production control and in intra-logistics, e.g. skid identification, container management, HF gates (F&B)
① RS-422/RS-232 interface,
24 V power supply
②
Digital I/O
③
External antenna
④
Operating display, 4 LEDs:
• Power (PWR)
• Active (ACT)
• Present (PRE)
• Error (ERR)
Note
Reader requires external antennas
Note that the RF290R reader is designed only for operation with external antennas and can only be operated in conjunction with the antennas ANT D5, D6 or D10.
5.6.2 Ordering data RF290R
Table 5- 1 Ordering data RF290R
RF290R with RS-232 interface for PC mode and RS-422 interface for CM mode
Article number
6GT2821-0AC12
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 105
Readers
5.6 SIMATIC RF290R
Table 5- 2 Ordering data - accessories - RF290R
24 V connecting cable
RS-232 connecting cable, with 4-pin M12 connector for
24 V for connection to the wide-range power supply unit
RS-232 connecting cable with open cable ends for 24
V
Adapter for mounting on a DIN rail (pack of 3)
5 m
5 m
5 m
Wide-range power supply unit for SIMATIC RF-systems
(100 - 240 VAC / 24 VDC / 3 A) with 2 m connecting cable with country-specific plug
Connecting cables
Reader ↔ ASM 475 2 m
5 m
Connecting / extension cable
Reader ↔ CM/ASM for RF200 / RF300 / RF600 / MV400 or extension cable MOBY U/D
2 m
5 m
10 m
20 m
50 m
Antennas
Antenna ANT D5
Antenna ANT D6
Covering hood for ANT D6
Antenna ANT D10
Accessories for connecting multiple antennas to SIMATIC RF290R
Antenna multiplexer incl. one antenna connecting cable 0.4 m
Antenna splitter incl. one antenna connecting cable 3.3 m
Antenna cables
Antenna cable
Antenna cable extension
3.3 m
10.5 m
7.2 m
Article number
6GT2491-1HH50
6GT2891-4KH50
6GT2691-0CH33
6GT2691-0CN10
6GT2691-0DH72
6GT2891-4KH50-0AX0
6GK5798-8ML00-0AB3
EU: 6GT2898-0AA00
UK: 6GT2898-0AA10
US: 6GT2898-0AA20
6GT2891-4EH20
6GT2891-4EH50
6GT2891-4FH20
6GT2891-4FH50
6GT2891-4FN10
6GT2891-4FN20
6GT2891-4FN50
6GT2698-5AA10
6GT2698-5AB00
6GT2690-0AD00
6GT2698-5AF00
6GT2894-0EA00
6GT2690-0AC00
106
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
5.6.3
RS422/RS232
Pin assignment RF290R
Table 5- 3 Pin assignment of the RS-422/RS 232 interface
Pin Pin
Device end 8pin M12
7
8
5
6
1
2
3
4
RS-422
+24 V
- Transmit
0 V
+ Transmit
+ Receive
- Receive not used
Ground (shield)
Interface assignment
RS-232
+24 V
RXD
0 V
TXD not used not used not used
Ground (shield)
Digital I/O
Readers
5.6 SIMATIC RF290R only possible in PC mode (RS-232)
Table 5- 4 Pin assignment of the digital I/O interface
Pin Pin
Device end 4pin M12
3
4
1
2
Socket assignment
DO - relay contact COM (Common)
DO - relay contact NO (Normaly Open, NO contact)
DI - switched input, +24 V
DI - ground, 0 V
Figure 5-14 Pin assignment of the power supply connector
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 107
Readers
5.6 SIMATIC RF290R
Digital input (DI):
The opto-coupler input is electrically isolated from the reader electronics. The external 24 V must be connected to the DI according to the circuit diagram. Make sure that the polarity of the 24 V is correct. The current is limited to < 10 mA by the integrated resistor.
NOTICE
Reader may be damaged
If you exceed the maximum permitted supply voltage, the reader may be damaged. Make sure that the input voltage does not exceed the maximum permitted supply voltage of the reader.
Digital output (DO):
At the relay output, a NO contact is available. The output is electrically isolated from the reader electronics and therefore needs to be supplied externally.
NOTICE
Reader may be damaged
If you exceed the maximum permitted voltage of 24 V / 1 A at the relay output, the reader may be damaged. Make sure that the voltage does not exceed 24 V.
The output is intended only for switching resistive loads. If it is used to switch inductive loads, the reader may be damaged. Make sure that if inductive loads occur, the relay contacts are protected by an external suppressor circuit.
108
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
5.6.4
Readers
5.6 SIMATIC RF290R
Display elements of the RF290R reader
LED
PWR flashing
ACT
PRE
ERR permanently lit
Meaning
CM mode:
Operating voltage present, reader not initialized or antenna switched off
CM mode:
Operating voltage present, reader initialized and antenna switched on
PC mode:
Supply voltage applied
Communication on the data line
Presence of a transponder in the antenna field
CM mode: flashing: The type of flashing corresponds to the error code in the table in the section "Error codes". The optical error display is only reset if the corresponding reset parameter ("option_1 = 2") is set (see product information "SIMATIC RF200 command set
( http://support.automation.siemens.com/WW/view/en/44864850 )").
PC mode: permanently lit: Error when connecting the antenna or the interference level in the antenna environment is too high
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 109
Readers
5.6 SIMATIC RF290R
5.6.5
5.6.5.1
Installing the RF290R reader
Wall mounting
Use the holes in the housing to screw the device to the wall or onto a horizontal surface. The position of the drill holes is shown in the following figure:
110
Figure 5-15 Drilling pattern for the RF290R (dimensions in mm)
A: M4 threaded socket for potential connection of the reader. You will find further information
on the potential connection in the section "Further information (Page 74)".
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
5.6.5.2
Readers
5.6 SIMATIC RF290R
Installing on the S7-300 standard rail
Follow the steps below to mount the RF290R reader on a vertical S7-300 standard rail:
1. Place the device on the upper edge of the S7-300 standard rail (position A).
2. Screw the device to the rail with the supplied screws (position B).
5.6.5.3
Figure 5-16 Installing the RF290R reader on the S7-300 standard rail
Installation on a DIN rail
The RF290R reader is suitable for installation on 35 mm rails that comply with DIN EN
50022.
Note
The adapter for mounting on a DIN rail does not ship with the RF290R
The adapter for mounting on a DIN rail does not ship with the product. You can obtain a pack of three with the following order number: 6GK5798-8ML00-0AB3.
The mounting fittings consist of the following parts:
• 1 DIN rail slider
• 1 spring
• 2 screws
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 111
Readers
5.6 SIMATIC RF290R
Fit the adapter to the rear of the device as shown in the following figure:
Figure 5-17 Mounting the DIN rail adapter
Follow the steps below to mount the RF290R reader on a DIN rail:
1. Place the device on the upper edge of the DIN rail (position A).
2. Pull the spring-mounted DIN rail slider (position B) down and press the device against the
DIN rail until it locks in place.
112
Figure 5-18 Mounting the RF290R reader on a DIN rail
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
5.6.6
Readers
5.6 SIMATIC RF290R
Technical specifications of the RF290R reader
Product type designation
Inductive interface to the transponder
Transmission frequency for power/data
Transponders supported
Connectable antennas
Interface
• Communications module
• PC
Baud rate
Cable length reader ↔ communications module
Transmit power
Multitag
Read/write distances of reader
Maximum data transmission rate reader ↔ transponder
• Read
• Write
Power supply
Display elements
Digital input / output
• Digital input
• Digital output
Connection
• Power supply/data line
• Digital IN/OUT
• Antennas
Housing
• Dimensions (L × W × H)
• Color
• Material
Securing
Ambient temperature
• During operation
• During transportation and storage
RF290R
6GT2821-0AC12
13.56 MHz
Transponder to ISO 15693
ANT D5, D6, D10
• RS-422 (3964R protocol)
• RS-232
19200, 57600, 115200 baud
RS-422: max. 1000 m
RS-232: Max. 30 m
(shielded cable) up to 5 W only in PC mode (RS-232)
Refer to chapter Field data (Page 35)
• approx. 1.5 KBps
• approx. 1.5 KBps
24 VDC
4 LEDs
(Power, Active, Presence, Error)
(only available in PC mode, RS-232)
• 1 x opto-coupler 24 V
• 1 x relay 24 V / 1 A
• M12, 8-pin, male
• M12, 4-pin, female
• TNC, female
• 200 × 140 × 80 mm (without device connector)
• Silver/anthracite
• Aluminum die-casting
M4 screws
Tightening torque ≤ 1.5 Nm
• -20 °C ... +55 °C
• -25 °C ... +85 °C
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 113
Readers
5.6 SIMATIC RF290R
Degree of protection to EN 60529
Shock-resistant to EN 60 721-3-7, Class 7 M2
Vibration-resistant to EN 60 721-3-7, Class 7 M2
IP65
30 g
2 g
6GT2821-0AC12
Weight
Approvals
Approx. 1.8 kg
Radio to R&TTE guidelines EN 300 330,
EN 301489, CE
FCC, IC, NTC (Thailand), KCC 1) typ. 400 mA Current consumption
1) Use a power supply unit that meets the following requirements: 230 VAC, 24 VDC / 3 A; KC safety approved
5.6.7 Approvals
FCC information
Siemens SIMATIC RF290R (MLFB 6GT2821-0AC12) FCC ID NXW-RF290R
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Caution
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Note
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
IC information
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device.
114
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
5.6.8
Readers
5.6 SIMATIC RF290R
Le présent appareil est conforme aux CNR d`Industrie Canada applicables aux appareils radio exempts de licence. L`exploitation est autorisée aux deux conditions suivantes :
(1) L`appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l`appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d`en compromettre le fonctionnement.
If the antenna is detachable, require the following two conditions:
(1) To reduce potential radio interference to other users, the antenna type should be chosen that the radiated power is not more than that permitted for successful communication.
(2) This device has been designed to operate with the antennas listed below. Antennas not included in this list are strictly prohibited for use with this device. The required antenna impedance is 50 Ω.
Si l'antenne est amovible, demandez les deux conditions suivantes :
(1) Afin de réduire le risque d'interférence aux autres utilisateurs, il faut choisir le type d'antenne et son gain de façon à ce que la puissance rayonnée ne soit pas supérieure au niveau requis pour l'obtention d'une communication satisfaisante.
(2) Ce dispositif a été conçu pour fonctionner avec les antennes énumérées ci-dessous. Les antennes non incluses dans cette liste sont strictement interdites pour l'exploitation de ce dispositif. L'impédance d'antenne requise est 50 Ω.
Note on the use of the RF290R as a replacement for SLG D10 / SLG D10S
The RF290R reader is the successor to the MOBY D readers SLG D10 / SLG D10S rounding off the RF200 family; it is operated with external antennas. The following features distinguish the RF290R from the SLG models:
Table 5- 5 Differences between the RF290R readers and SLG D10 / SLG D10S
Properties SLG D10/SLG D10S
Two devices with different interfaces
M 12, 4-pin male connector for the power supply
9-pin D-sub male connector for connection to the various communications modules no digital I/O no operating display via LEDs
Maximum transmit power of 10 W
One securing option
Standard protocol in ISO host mode (in PC mode)
Amplitude Shift Keying (ASK) and Frequency
Shift Keying (FSK) modes possible
Properties RF290R
RS-232/RS-422 interface and PC/CM functionality in one device
M12, 8-pin male connector for the power supply and for direct connection to the various communications modules 1)
M12, 4-pin female connector for digital I/O (can only be used in PC mode) operating display by four LEDs
Maximum transmit power of 5 W
Different securing options
Advanced protocol in ISO host mode (in PC mode) 2)
Amplitude Shift Keying (ASK) mode possible
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 115
Readers
5.6 SIMATIC RF290R
Properties SLG D10/SLG D10S Properties RF290R
Support of "ICode1" and "TagIt" and ISO 15693compatible transponders
Support of ISO 15693-compatible transponders
The total memory for "repeat_command" is limited to 32 kB
The total memory for "repeat_command" is limited to 16 kB
1) The RF290R reader connectors are compatible with the SLG D10 if a Y connecting cable is used
(6GT2891-4KH50, 6GT2891-4KH50-0AX0).
2) In ISO host mode (in PC mode), a program adaptation is necessary
5.6.9 Dimension drawing
116
Figure 5-19 Dimensional drawing RF290R (dimensions in mm)
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Antennas
6
Note
The RF250R and RF290R readers require external antennas
Note that the RF250R and RF290R readers are designed for operation with external antennas.
The RF250R reader can only be used in conjunction with the antennas ANT 8, 12, 18 or 30.
The RF290R reader can only be used in conjunction with the antennas ANT D5, D6 or D10.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 117
Antennas
6.1 ANT 8
6.1 ANT 8
6.1.1
ANT 8
Features
Characteristics
Area of application Tool identification
Writing/reading distance up to 4 mm (depending on the transponder)
Connecting cable
Connectable readers
Degree of protection
3 m
RF250R
IP67
6.1.2 Ordering data
Table 6- 1 Ordering data ANT 8
Antenna
ANT 8
(incl. one antenna connecting cable 3 m)
ANT 8
(without antenna cable)
Table 6- 2 Ordering data ANT 8 accessories
Accessories
Antenna connecting cable with M8 plug (with angled plug)
Article number
6GT2398-1CF10
6GT2398-1CF00
Article number
6GT2391-0AH30
118
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
6.1.3 Transmission window
Antennas
6.1 ANT 8
L d
Length of the transmission window (= 3 mm)
S a
Operating distance between antenna and transponder
S g
Limit distance (maximum clear distance between upper surface of the reader and the antenna, at which the transmission can still function under normal conditions)
Figure 6-1 Transmission window ANT 8
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 119
Antennas
6.1 ANT 8
6.1.4 Flush-mounted in metal
Figure 6-2 ANT 8 flush-mounted in metal
6.1.5 Minimum spacing
Note
Extension of the data transmission time if distance values are undershot
If the distance values specified in the tables are undershot, it is possible that the inductive fields will be affected. In this case, the data transmission time can increase unpredictably or a command is aborted with an error.
For this reason, please observe the values in the tables.
Minimum distances from transponder to transponder (without multitag mode)
RF250R with ANT 8
MDS D117 / MDS D127
≥ 20 mm
MDS D421
≥ 30 mm
120
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Definition of distance D
D > 30 mm (with 2 antennas)
> 30 mm (with 3 antennas)
Figure 6-3 Minimum distance for ANT 8
Antennas
6.1 ANT 8
D > 50 mm
Figure 6-4 Face-to-face distance between two ANT 8s
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 121
Antennas
6.1 ANT 8
6.1.6 Technical data
Product type designation
Max. write/read distance
ANT - transponder (S g
)
Dimensions (∅ × pitch × L)
Color
Material
Plug connection
Antenna cable length
Shock resistant according to EN 60721-3-7
Class 7M2
Total shock response spectrum Type II
Vibration resistance in accordance with
EN 60721-3-7, Class 7M2
Attachment of the antenna
Ambient temperature
• During operation
• During transportation and storage
ANT 8
4 mm
M8 × 1.0 mm × 40 mm silver-metallic
Stainless steel
4-pin (pins on antenna side)
3 m
50 g 1)
20 g (3 ... 500 Hz) 1)
2 stainless steel nuts, M8 × 1.0 mm
• -25 °C ... +70 °C
• -40 °C ... +85 °C
6GT2398-1CC00
Degree of protection to EN 60529
Weight, approx.
IP67
45 g
1) Warning: The values for shock and vibration are maximum values and must not be applied continuously.
6.1.7 Dimension drawing
Figure 6-5 Dimension drawing ANT 8 (all values in mm)
122
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
6.2
6.2.1
ANT 12
ANT 12
Features
Characteristics
Area of application Tool identification
Writing/reading distance up to 16 mm (depending on the transponder)
Connecting cable
Connectable readers
Degree of protection
3 m
RF250R
IP67 (front)
Antennas
6.2 ANT 12
6.2.2 Ordering data
Table 6- 3 Ordering data ANT 12
Antenna
ANT 12
(incl. one antenna connecting cable 3 m)
Article number
6GT2398-1CC00
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 123
Antennas
6.2 ANT 12
6.2.3 Transmission window
124
L d
Length of the transmission window (= 20 mm)
S a
Operating distance between antenna and transponder
S g
Limit distance (maximum clear distance between upper surface of the reader and the antenna, at which the transmission can still function under normal conditions)
Figure 6-6 Transmission window ANT 12
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
6.2.4 Flush-mounted in metal
Antennas
6.2 ANT 12
Figure 6-7 ANT 12 flush-mounted in metal
6.2.5 Minimum spacing
Note
Extension of the data transmission time if distance values are undershot
If the distance values specified in the tables are undershot, it is possible that the inductive fields will be affected. In this case, the data transmission time can increase unpredictably or a command is aborted with an error.
For this reason, please observe the values in the tables.
Minimum distances from transponder to transponder (without multitag mode)
MDS D117 / MDS D127
≥ 60 mm
MDS D421 / MDS D422 / MDS D428 / MDS
D460
≥ 80 mm RF250R with ANT 12
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 125
Antennas
6.2 ANT 12
Definition of distance D
D > 30 mm (with 2 antennas)
> 40 mm (with 3 antennas)
Figure 6-8 Minimum distance for ANT 12
126
D > 100 mm
Figure 6-9 Face-to-face distance between two ANT 12s
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
6.2.6 Technical data
Product type designation
Max. write/read distance
ANT - transponder (S g
)
Dimensions (∅ × pitch × L)
Color
Material
Plug connection
Antenna cable length
Shock resistant according to EN 60721-3-7
Class 7M2
Total shock response spectrum Type II
Vibration resistance in accordance with
EN 60721-3-7, Class 7M2
Attachment of the antenna
Ambient temperature
• During operation
• During transportation and storage
ANT 12
16 mm
M12 × 1.0 mm × 40 mm
Pale turquoise
Plastic Crastin
4-pin (pins on antenna side)
3 m
50 g 1)
20 g (3 ... 500 Hz) 1)
2 plastic nuts, M12 × 1.0 mm
• -20 °C ... +70 °C
• -40 °C ... +85 °C
6GT2398-1CC00
Degree of protection according to EN 60529
Weight, approx.
IP67 (front)
45 g
1) Warning: The values for shock and vibration are maximum values and must not be applied continuously.
Antennas
6.2 ANT 12
6.2.7 Dimension drawing
Figure 6-10 Dimension drawing ANT 12 (all values in mm)
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 127
Antennas
6.3 ANT 18
6.3 ANT 18
6.3.1
ANT 18
Features
Characteristics
Area of application Small assembly lines
Writing/reading distance up to 35 mm (depending on the transponder)
Connecting cable
Connectable readers
Degree of protection
3 m
RF250R
IP67 (front)
6.3.2 Ordering data
Table 6- 4 Ordering data ANT 18
Antenna
ANT 18
(incl. one antenna connecting cable 3 m)
Article number
6GT2398-1CA00
128
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
6.3.3 Transmission window
Antennas
6.3 ANT 18
L d
Length of the transmission window (= 30 mm)
S a
Operating distance between antenna and transponder
S g
Limit distance (maximum clear distance between upper surface of the reader and the antenna, at which the transmission can still function under normal conditions)
Figure 6-11 Transmission window ANT 18
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 129
Antennas
6.3 ANT 18
6.3.4 Flush-mounted in metal a = 10 mm b = 10 mm
Figure 6-12 ANT 18 flush-mounted in metal
6.3.5 Minimum spacing
Note
Extension of the data transmission time if distance values are undershot
If the distance values specified in the tables are undershot, it is possible that the inductive fields will be affected. In this case, the data transmission time can increase unpredictably or a command is aborted with an error.
For this reason, please observe the values in the tables.
Minimum distances from transponder to transponder (without multitag mode)
MDS D124 / MDS D160 / MDS D324
≥ 80 mm
MDS D421 / MDS D422 / MDS D423 /
MDS D424 / MDS D425 / MDS D428 /
MDS D460
≥ 100 mm RF250R with ANT 18
130
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Definition of distance D
D > 30 mm (with 2 antennas)
> 40 mm (with 3 antennas)
Figure 6-13 Minimum distance for ANT 18
Antennas
6.3 ANT 18
D > 100 mm
Figure 6-14 Face-to-face distance between two ANT 18s
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 131
Antennas
6.3 ANT 18
6.3.6 Technical data
Product type designation
Max. write/read distance
ANT - transponder (S g
)
Dimensions (∅ × pitch × L)
Color
Material
Plug connection
Antenna cable length
Shock resistant according to EN 60721-3-7
Class 7M2
Total shock response spectrum Type II
Vibration resistance in accordance with
EN 60721-3-7, Class 7M2
Attachment of the antenna
Ambient temperature
• During operation
• During transportation and storage
ANT 18
35 mm
M18 × 1.0 mm × 55 mm
Pale turquoise
Plastic Crastin
4-pin (pins on antenna side)
3 m
50 g 1)
20 g (3 ... 500 Hz) 1)
2 plastic nuts, M18 × 1.0 mm
• -20 °C ... +70 °C
• -40 °C ... +85 °C
6GT2398-1CC00
Degree of protection according to EN 60529
Weight, approx.
IP67 (front)
120 g
1) Warning: The values for shock and vibration are maximum values and must not be applied continuously.
6.3.7 Dimension drawing
Figure 6-15 Dimension drawing ANT 18 (all values in mm)
132
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
6.4
6.4.1
ANT 18
ANT 30
Features
Characteristics
Area of application Small assembly lines
Writing/reading distance up to 55 mm (depending on the transponder)
Connecting cable
Connectable readers
Degree of protection
3 m
RF250R
IP67 (front)
Antennas
6.4 ANT 30
6.4.2 Ordering data
Table 6- 5 Ordering data ANT 30
Antenna
ANT 30
(incl. one antenna connecting cable 3 m)
Article number
6GT2398-1CD00
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 133
Antennas
6.4 ANT 30
6.4.3 Transmission window
134
L d
Length of the transmission window (= 60 mm)
S a
Operating distance between antenna and transponder
S g
Limit distance (maximum clear distance between upper surface of the reader and the antenna, at which the transmission can still function under normal conditions)
Figure 6-16 Transmission window ANT 30
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
6.4.4 Flush-mounted in metal
Antennas
6.4 ANT 30 a = 20 mm b = 20 mm
Figure 6-17 ANT 30 flush-mounted in metal
6.4.5 Minimum spacing
Note
Extension of the data transmission time if distance values are undershot
If the distance values specified in the tables are undershot, it is possible that the inductive fields will be affected. In this case, the data transmission time can increase unpredictably or a command is aborted with an error.
For this reason, please observe the values in the tables.
Minimum distances from transponder to transponder (without multitag mode)
MDS D124 / MDS D160 /
MDS D324 / MDS D423 /
MDS D424 / MDS D460
≥ 100 mm
MDS D422 / MDS D425 /
MDS D428
≥ 80 mm
MDS MDS D126 / MDS D426
≥ 150 mm RF250R with ANT 30
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 135
Antennas
6.4 ANT 30
Definition of distance D
D > 40 mm (with 2 antennas)
> 50 mm (with 3 antennas)
Figure 6-18 Minimum distance for ANT 30
136
D > 200 mm
Figure 6-19 Face-to-face distance between two ANT 30s
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
6.4.6 Technical data
Product type designation
Max. write/read distance
ANT - transponder (S g
)
Dimensions (∅ × pitch × L)
Color
Material
Plug connection
Antenna cable length
Shock resistant according to EN 60721-3-7
Class 7M2
Total shock response spectrum Type II
Vibration resistance in accordance with
EN 60721-3-7, Class 7M2
Attachment of the antenna
Ambient temperature
• During operation
• During transportation and storage
ANT 30
60 mm
M30 × 1.0 mm × 58 mm
Pale turquoise
Plastic Crastin
4-pin (pins on antenna side)
3 m
50 g 1)
20 g (3 ... 500 Hz) 1)
2 plastic nuts, M30 × 1.0 mm
• -20 °C ... +70 °C
• -40 °C ... +85 °C
6GT2398-1CC00
Degree of protection to EN 60529
Weight, approx.
IP67 (front)
150 g
1) Warning: The values for shock and vibration are maximum values and must not be applied continuously.
Antennas
6.4 ANT 30
6.4.7 Dimension drawing
Figure 6-20 Dimension drawing ANT 30 (all values in mm)
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 137
Antennas
6.5 ANT D5
6.5 ANT D5
6.5.1
ANT D5
Features
Characteristics
Area of application
Writing/reading distance
Connecting cable
Readers that can be connected
Degree of protection
Storage, logistics and distribution up to 500 mm (depending on the transponder)
3.3 m
RF290R
IP65
6.5.2 Ordering data
Table 6- 6 Ordering data of ANT D5
Antenna
ANT D5
(incl. one antenna connecting cable 3.3 m)
Article number
6GT2698-5AA10
Table 6- 7 Ordering data of ANT D5 accessories
Accessories
Antenna splitter
(incl. one antenna connecting cable 3.3 m)
Antenna multiplexer
(incl. one antenna connecting cable 0.4 m)
Antenna cable
Antenna extension cable, length 7.2 m
Article number
6GT2690-0AC00
6GT2894-0EA00
Length 3.3 m 6GT2691-0CH33
Length 10.5 m 6GT2691-0CN10
6GT2691-0DH72
138
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
6.5.3 Transmission window
Antennas
6.5 ANT D5
L d
Length of the transmission window (= 300 mm)
S a
Operating distance between antenna and transponder
S g
Limit distance (maximum clear distance between upper surface of the reader and the antenna, at which the transmission can still function under normal conditions)
Figure 6-21 Transmission window for ANT D5
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 139
Antennas
6.5 ANT D5
6.5.4 Flush-mounted in metal a = 150 mm
Figure 6-22 Metal-free area for ANT D5
6.5.5 Minimum spacing
Note
Extension of the data transmission time if distance values are undershot
If the distance values specified in the tables are undershot, it is possible that the inductive fields will be affected. In this case, the data transmission time can increase unpredictably or a command is aborted with an error.
For this reason, please observe the values in the tables.
140
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Antennas
6.5 ANT D5
Minimum distances from transponder to transponder (without multitag mode)
MDS D100 / MDS D126 / MDS D139 /
MDS D165 / MDS D200 / MDS D261 /
MDS D339 / MDS D400 / MDS D426
≥ 1 m
MDS D124 / MDS D160 / MDS D324 /
MDS D424 / MDS D428 / MDS D460
≥ 0.8 m RF290R
Minimum distances from antenna to antenna
RF290R with ANT D5
RF290R with ANT D6
RF290R with ANT D10
RF290R with ANT D5
≥ 2 m
≥ 2 m
≥ 2 m
Definition of distance D
RF290R with ANT D6
≥ 2 m
≥ 2 m
≥ 2 m
RF290R with ANT D10
≥ 2 m
≥ 2 m
≥ 2 m
Figure 6-23 Distance D: ANT D5
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 141
Antennas
6.5 ANT D5
6.5.6 Technical data
Technical specifications
Max. write/read distance
ANT to MDS (S g
)
Dimensions (L x W x H)
Color
Material
Plug connection
Max. power
Antenna cable length
Shock resistant according to EN 60721-3-7
Class 7M2
Total shock response spectrum Type II
Vibration according to EN 60721-3-7 Class
7M2
Attachment of the antenna
Ambient temperature
• During operation
• During transportation and storage
MTBF
Degree of protection according to EN 60529
Weight, approx.
Approvals
500 mm
380 x 380 x 110 mm gray/black
Aluminum/plastic
1-pin TNC connector
10 W
(FCC/IC: 4 W)
3.3 m
30 g
1 g (9 to 200 Hz) / 1.5 g (200 to 500 Hz)
4 M6 or alternatively M8 screws
• -20 ℃ ... +55 ℃
• -25 ℃ ... +70 ℃
10 7 hours
IP65 (UL: for indoor use only)
1.2 kg
CE
FCC, IC (as of 04/2013)
142
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
6.5.7 Dimension drawing
Antennas
6.5 ANT D5
Figure 6-24 Dimension drawing for ANT D5
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 143
Antennas
6.6 ANT D6
6.6 ANT D6
6.6.1
ANT D6
Features
6.6.2
Characteristics
Area of application
Writing/reading distance
Connecting cable
Cover
Readers that can be connected
Degree of protection
• Storage, logistics and distribution
• Suitable for high-speed applications with large writing/reading distance up to 650 mm (depending on the transponder)
3.3 m; included in scope of supply
Available as accessory
RF290R
IP65 (also without cover)
Ordering data
Table 6- 8 ANT D6 ordering data
Antenna
ANT D6
(without cover, incl. one antenna connecting cable 3.3 m)
Table 6- 9 Ordering data for ANT D6 accessories
Accessories
Covering hood for ANT D6
Antenna splitter
(incl. one antenna connecting cable 3.3 m)
Antenna multiplexer
(incl. one antenna connecting cable 0.4 m)
Antenna cable Length 3.3 m
Length 10.5 m
Antenna extension cable, length 7.2 m
Article number
6GT2698-5AB00
Article number
6GT2690-0AD00
6GT2690-0AC00
6GT2894-0EA00
6GT2691-0CH33
6GT2691-0CN10
6GT2691-0DH72
144
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
6.6.3 Transmission window
Antennas
6.6 ANT D6
L x
= 520 mm
L y
= 420 mm
Figure 6-25 Transmission window for ANT D6
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 145
Antennas
6.6 ANT D6
6.6.4 Metal-free area
Flush-mounted in metal
Figure 6-26 Metal-free area for ANT D6
6.6.5 Minimum spacing
Definition of distance D
146
Figure 6-27 Distance D: ANT D6
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
6.6.6 Technical data
Technical specifications
Max. write/read distance
ANT to MDS (S g
)
Dimensions (L x W x H)
650 mm
Color
Material
Plug connection
Max. power
580 x 480 x 110 mm
(without cover) gray/black
Aluminum/plastic
1-pin TNC connector
10 W
(FCC/IC: 2.5 W)
3.3 m
30 g
Antenna cable length
Shock resistant according to EN 60721-3-7
Class 7M2
Total shock response spectrum Type II
Vibration according to EN 60721-3-7 Class
7M2
Attachment of the antenna
Ambient temperature
•
•
During operation
During transportation and storage
1 g (9 to 200 Hz) / 1.5 g (200 to 500 Hz)
4 x M6 screws
• -20 ℃ ... +55 ℃
• -25 ℃ ... +70 ℃
MTBF 3 x 10 5 hours
Degree of protection according to EN 60529 IP65 (UL: for indoor use only)
Weight, approx. 3.3 kg
Approvals CE
FCC, IC (as of 04/2013)
Antennas
6.6 ANT D6
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 147
Antennas
6.6 ANT D6
6.6.7 Dimensional diagram
148
Figure 6-28 Dimension drawing for ANT D6
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
6.7 ANT D10
Antennas
6.7 ANT D10
6.7.1
ANT D10
Features
Characteristics
Area of application
Writing/reading distance
Connecting cable
Cover
Readers that can be connected
• Storage, logistics and distribution, e.g. clothing industry, laundries
• Particularly when small MDS are used (e.g. MDS D124,
MDS D160) and when there is a long transmission field up to 480 mm (depending on the transponder)
3.3 m; included in scope of supply
Included in scope of supply
RF290R
6.7.2 Ordering data
Table 6- 10 Ordering data of ANT D10
Antenna
ANT D10
(incl. cover and one antenna connecting cable 3.3 m)
Table 6- 11 Ordering data of ANT D10 accessories
Accessories
Antenna splitter
(incl. one antenna connecting cable 3.3 m)
Antenna multiplexer
(incl. one antenna connecting cable 0.4 m)
Antenna cable Length 3.3 m
Length 10.5 m
Antenna extension cable, length 7.2 m
Article number
6GT2698-5AF00
Article number
6GT2690-0AC00
6GT2894-0EA00
6GT2691-0CH33
6GT2691-0CN10
6GT2691-0DH72
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 149
Antennas
6.7 ANT D10
6.7.3 Transmission window
150
L x
L y
1050 mm
350 mm
Figure 6-29 Transmission window for ANT D10
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
6.7.4 Metal-free area
Flush-mounted in metal
Antennas
6.7 ANT D10
Figure 6-30 Metal-free area for ANT D10
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 151
Antennas
6.7 ANT D10
6.7.5 Minimum spacing
Definition of distance D
Figure 6-31 Distance D: ANT D10
152
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
6.7.6 Technical data
Technical specifications
Max. write/read distance
ANT to MDS (S g
)
Dimensions (L x W x H)
480 mm
Color
Material
Plug connection
Max. power
1150 x 365 x 115 mm
(with cover) gray/black
Aluminum/plastic
1-pin TNC connector
10 W
(FCC/IC: 2.5 W)
3.3 m
30 g
Antenna cable length
Shock resistant according to EN 60721-3-7
Class 7M2
Total shock response spectrum Type II
Vibration according to EN 60721-3-7 Class
7M2
Attachment of the antenna
Ambient temperature
•
•
During operation
During transportation and storage
1 g (9 to 200 Hz) / 1.5 g (200 to 500 Hz)
4 x M6 screws
• -20 ℃ ... +55 ℃
• -25 ℃ ... +70 ℃
MTBF 3 x 10 5 hours
Degree of protection according to EN 60529 IP65 (UL: for indoor use only)
Weight, approx. 10 kg
(with cover)
Approvals CE
FCC, IC (as of 04/2013)
Antennas
6.7 ANT D10
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 153
Antennas
6.7 ANT D10
6.7.7 Dimensional diagram
154
Figure 6-32 Dimension drawing for ANT D10
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Transponder
7
7.1 MDS D100
7.1.1
MDS D100
Characteristics
Characteristics
Field of application
Memory
Read/write range
Mounting on metal
ISO standard
7.1.2 Ordering data
Table 7- 1 Ordering data for MDS D100
MDS D100
Table 7- 2 Ordering data for MDS D100 accessory
MDS D100 accessory
Spacer
Holder
Holder (cannot be mounted directly on metal)
From simple identification such as electronic barcode replacement/supplementation, through warehouse and distribution logistics, right up to product identification.
EEPROM 128 bytes gross
112 bytes net capacity
See Chapter Field data (Page 35).
Not possible; recommended distance from metal ≥ 20 mm
ISO 15693
Order number
6GT2600-0AD10
Order number
6GT2190-0AA00
6GT2190-0AB00
6GT2390-0AA00
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 155
Transponder
7.1 MDS D100
7.1.3 Metal-free area
Direct mounting of the MDS D100 on metal is not allowed. A distance of ≥ 20 mm is recommended. This can be achieved using the spacer 6GT2190-0AA00 in combination with the fixing pocket 6GT2190-0AB00.
Mounting on metal
h ≥ 20 mm
①
Data memory
②
Metal
③
Non-metal
Figure 7-1 Mounting of the MDS D100 on metal with spacer
156
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Flush-mounting
Transponder
7.1 MDS D100 a ≥ 20 mm h ≥ 20 mm
①
Data memory
②
Metal
③
Non-metal
Figure 7-2 Flush-mounting of MDS D100 in metal with spacer
Note
If the minimum guide values (h) are not observed, a reduction of the field data results.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 157
Transponder
7.1 MDS D100
7.1.4 Technical data
Table 7- 3 Technical data for MDS D100
Memory size
Memory configuration
• Serial number
• Configuration memory
• Application memory
Storage technology
Memory organization
Protocol
Data retention (at +40 °C)
MTBF (at +40 °C)
Read cycles
Write cycles, typical
Write cycles, min.
Read/write distance (S g
)
Distance from metal
Multitag capability
Power supply
Degree of protection to EN 60529
Vibration
Torsion and bending load
Mechanical design
•
•
•
•
•
Color
Material
Dimensions (L x W x H) in mm
Fixing
Ambient temperature
During operation
Transport and storage
Weight, approx.
128 bytes
• 8 bytes (fixed code)
• 8 bytes
• 112 bytes
EEPROM
EEPROM 128 bytes gross
112 bytes net capacity
When using the OPT area, 16 bytes of it must be subtracted in 4 byte blocks according to ISO 15693
10 years
2 x 10 6 hours
Unlimited
1 000 000
100 000
See Chapter Field data (Page 35).
min. 20 mm (approx. 30% reduction of the field data)
Yes
Inductive power transmission (without battery)
IP68
ISO 10373/ISO 7810
ISO 10373/ISO 7816-1
Laminated plastic card, printable on both sides
• White/petrol
• PC
• 85.6 (±0.2) x 54 (±0.2) x 0.9 (±0.05)
Adhesive, fixing pocket
• -25 °C to +80 °C
• -25 °C to +80 °C
5 g
158
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
7.1.5 Dimension drawing
Dimensions in mm
1) Dimensions for mounting holes
Figure 7-3 MDS D100 dimension drawing
Transponder
7.1 MDS D100
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 159
Transponder
7.2 MDS D117
7.2 MDS D117
7.2.1
MDS D117
Features
Characteristics
Area of application
Memory
Read/write range
Mounting in metal
ISO standard
Very compact data carrier that can be screwed into areas where precise positioning is necessary; e.g. tool identification, workpiece holders etc.
128 bytes EEPROM/gross
112 bytes user memory
See chapter "Field data (Page 35)."
Flush mounted
ISO 15693
7.2.2 Ordering data
Table 7- 4 Ordering data for MDS D117
Transponder
MDS D117
Pack of 10
Order number
6GT2600-0AG00
7.2.3 Mounting in metal
Flush-mounted in metal
160
①
Transponder
②
Metal
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Transponder
7.2 MDS D117
7.2.4 Technical specifications
Product type designation
Memory size
Memory configuration
• Serial number
• Configuration memory
• Application memory
MDS D117
128 bytes
• 8 bytes (fixed code)
• 8 bytes
• 112 bytes
6GT2600-0AG00
Storage technology
Memory organization
Data retention (at +40 °C)
MTBF (at +40 °C)
Read cycles
Write cycles (at +40 °C)
• minimum
• Typical
Read/write distance (S g
)
Multitag capability
Power supply
Degree of protection according to EN 60529
Degree of protection according to DIN 40050 Part 9
Shock according to EN 60721-3-7, Class 7M3
Total shock response spectrum, Type II
Vibration-resistant to EN 60721-3-7, Class 7M3
Torsion and bending load
Housing
•
•
•
Dimensions (D x H)
Color
Material
EEPROM
Refer to the RF200 or RF300 system manual, section
"Memory configuration of the ISO tags"
10 years
≥ 2 x 10 6 hours unlimited
•
•
100 000
1 000 000
See section "Field data (Page 35)."
Yes inductive power transmission (without battery)
IP68 1)
IPx9K 2)
100 g 3)
20 g 3) not permitted
• 4 mm (+0.2) × 5.2 mm (+0.3)
• Black
• Plastic PPS
Securing
Ambient temperature
• During operation
• During transportation and storage
Cement in
•
•
-25 ... +85 °C
-40 ... +100 ℃
Weight
1) 2 hours, 2 m, +20 °C
Approx. 1 g
2) steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C
3) The values for shock and vibration are maximum values and must not be applied continuously.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 161
Transponder
7.2 MDS D117
7.2.5 Dimension drawing
Figure 7-4 Dimensions in mm
162
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
7.3 MDS D124
7.3.1
MDS D124
Characteristics
Characteristics
Field of application
Memory
Read/write range
Mounting on metal
ISO standard
Degree of protection
Material
7.3.2 Ordering data
Table 7- 5 Ordering data for MDS D124
MDS D124
Order number
6GT2600-0AC10
Table 7- 6 Ordering data for MDS D124 accessories
Spacer
Order number
6GT2690-0AK00
Transponder
7.3 MDS D124
Application areas in production automation (e.g. small paintshops up to +180 °C)
128 bytes EEPROM/gross
112 bytes user memory
See section "Field data (Page 35)".
With spacer:
Recommended distance from metal ≥ 15 mm
ISO 15693
IP68, IPx9K
Plastic PPS, silicone-free
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 163
Transponder
7.3 MDS D124
7.3.3 Mounting on metal
Mounting on metal
Direct mounting of the MDS D124 on metal is not possible. A distance of ≥ 15 mm is recommended. This can be achieved by mounting the transponder on a spacer, (see section
h ≥ 15 mm
Figure 7-5 Mounting of the MDS D124 on metal with spacer
Flush-mounted in metal
It is possible to mount the MDS D124 in metal. However, with large antennas (for example
ANT D5) this leads to a reduction of the ranges.
164 h a
≥ 15 mm
≥ 25 mm
Figure 7-6 Flush-mounting of MDS D124 in metal with spacer
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
7.3.4
Transponder
7.3 MDS D124
Technical specifications
Table 7- 7 Technical data for MDS D124
Memory size
Memory configuration
• Serial number
• Configuration memory
• Application memory
Storage technology
Memory organization
Data retention (at +40 °C)
MTBF (at +40 °C)
Read cycles
Write cycles (at +40 °C)
•
• minimum
Typical
Read/write distance (S
Distance from metal g
)
128 bytes
• 8 bytes (fixed code)
• 8 bytes
• 112 bytes
EEPROM
Refer to the MOBY D system manual, RF200 or
RF300 section "Memory configuration of the ISO tags"
10 years
≥ 2 x 10 6 hours
Unlimited
• 100 000
• 1 000 000
See section "Field data (Page 35)."
at least 15 mm (approx. 30% reduction of the field data)
Yes
2 W
Multitag capability
Maximum reader power in hazardous area
Maximum field strength for operation in hazardous area
Power supply
Degree of protection to EN 60529
Shock according to EN 60721-3-7, Class 7M3
Total shock response spectrum, Type II
Vibration-resistant to EN 60721-3-7, Class
7M3
Torsion and bending load
Enclosure
• Dimensions (D x H)
• Color
• Material
Fixing
Tightening torque
5 A / m
Inductive power transmission
(without battery)
IP68 1)
IPx9K 2)
100 g 3)
20 g 3)
Not permissible
• 27 x 4 mm (±0.2 mm)
• Black
• Plastic PPS, silicone-free
Adhesive, M3 screw, snap-in (spacer)
≤ 1 Nm
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 165
Transponder
7.3 MDS D124
Ambient temperature During operation -25 ... +100 ℃
+120 ... +140 ℃
+200 ℃
+220 ℃
4)
4)
Permanent
20% reduction in the limit distance
Tested up to 5000 hours or 3000 cycles
Tested up to 2000 hours or 1500 cycles
Transport and storage
-40 ... +100 ℃
Weight
1) 2 hours, 2 m, +20 °C approx. 50 g
2) steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C
3) The values for shock and vibration are maximum values and must not be applied continuously.
4) Note that processing is not possible at temperatures of +140 °C or higher.
7.3.5
Identification
Use of the MDS D124 in hazardous area
The mobile data memory MDS D124, device group II, category 1G or 1D may be installed and operated in zones 0, 1 and 2 or in the zones 20, 21 and 22.
The requirements of the directive 94/9/EC are met by the use of the following standards:
EN 60079-0:2009, EN 60079-11:2007, EN 61241-11:2006 and EN 60079-26:2007
When used in hazardous areas, the MDS D124 must not be operated with field strengths > 5
A / m to avoid impermissible heating. This is not the case with readers from the SIMATIC RF range (MOBY D, RF200 and RF300).
II 1 G Ex ia IIC T3 to T6 Ga or
II 1 D Ex ia IIIC T80 °C to T180 °C Da
TÜV 12 ATEX 084413 X
The temperature class or the maximum surface temperature depends on the maximum ambient temperature. The relationship between temperature class (gas) or maximum surface temperature (dust) can be found in the following table.
166
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Transponder
7.3 MDS D124
Table 7- 8 Ambient temperature
Ambient temperature range
-25 ... +150 ℃
-25 ... +100 ℃
-25 ... +65 ℃
-25 ... +50 ℃
Temperature class
T3
T4
T5
T6
Max. surface temperature
T180
T130
T95
T80
Note
Safety markings for hazardous areas
Since there is not enough space on the MDS D124 for the safety mark, this is supplied as a label with the device.
This must be affixed immediately next to the MDS D124 so that the label clearly relates to the device.
WARNING
Danger due to electrostatic discharge
NOTICE
Installation and operating conditions for hazardous areas:
• The device may not be used in areas influenced by processes that generate high electrostatic charges.
• The device must be installed so that it is mechanically protected.
• For applications requiring devices of category 1, the device must be mounted on a grounded, conductive base.
• It must only be cleaned with a damp cloth.
• The device is suitable for use in atmospheres containing dust, however not for full immersion in dust.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 167
Transponder
7.4 MDS D126
7.3.6 Dimension drawing
Dimensions in mm
Figure 7-7 Dimension drawing of MDS D124
7.4 MDS D126
7.4.1
MDS D126
Characteristics
Characteristics
Fields of application
Memory
Read/write range
Standard
7.4.2 Ordering data
Table 7- 9 Ordering data for MDS D126
MDS D126
Order number
6GT2600-0AE00
Compact and rugged ISO transponder; suitable for identification of transport units in production-related logistics; can also be deployed in harsh conditions
EEPROM 128 bytes / gross
112 bytes net
See Section Field data (Page 35)
ISO-15693
168
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
7.4.3
Transponder
7.4 MDS D126
Technical specifications
Table 7- 10 Technical data for MDS D126
Memory size
Memory configuration
• Serial number
• Configuration memory
• Application memory
Storage technology
Memory organization
Protocol
Data retention (at +40 °C)
Data transmission rate
• read
• write
128 bytes
• 8 bytes (fixed code)
• 8 bytes
• 112 bytes
EEPROM
EEPROM 128 bytes gross
112 bytes net
When using the OTP area, 16 bytes of it must be subtracted in 4-byte blocks
ISO 15693
10 years
•
• approx. 2 ms/byte approx. 10 ms/byte
Bulk detection/multitag capability
Read cycles
Write cycles at +40 °C, typical
Read/write distance (S
Distance from metal
Power supply g
)
Yes
Unlimited min. 100,000 typ. 1,000,000
See Section Field data (Page 35)
≥ 25 mm (approx. 25 % reduction of the field data)
Inductive power transmission
(without battery)
Degree of protection to EN 60529
Shock, tested in accordance with IEC 68-2-27
Vibration, tested in accordance with IEC 68-2-6 20 g 2)
Torsion and bending load Not permissible
Enclosure
IP68 1)
50 g 2)
• Color
• Material
• Dimensions (D x H) in mm
• Mounting hole (d in mm)
•
•
•
•
Black
Plastic PA 6.6 GF
50 (±0.3) x 3.6 (±0.2)
5,1 (±0,2)
MDS fixing M4 screws, tightening torque (at room temperature) ≤ 1 Nm, adhesive
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 169
Transponder
7.4 MDS D126
7.4.4
Ambient temperature
• During operation
• Transport and storage
•
•
-25 °C to +85 °C
-40 °C to +100 °C
Weight, approx.
1) 2 hours, 2 m, +20 °C
13 g
2) The values for shock and vibration are maximum values and must not be applied continuously.
Note
It is recommended that a test is performed in critical applications.
Dimension drawing
Dimensions in mm
Figure 7-8 Dimension drawing of MDS D126
170
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
7.5 MDS D127
7.5.1
MDS D127
Features
Transponder
7.5 MDS D127
Features
Area of application
Memory
Reading / writing range
Mounting in metal
ISO standard
Very compact data carrier that can be screwed into areas where precise positioning is necessary; e.g. tool identification, workpiece holders etc.
128 bytes EEPROM/gross
112 bytes user memory
See section "Field data (Page 35)"
Flush mounted
ISO 15693
7.5.2 Ordering data
Table 7- 11 Ordering data for MDS D127
Product
MDS D127
Pack of 10
(A screw-in aid is supplied with each pack)
Order number
6GT2600-0AF00
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 171
Transponder
7.5 MDS D127
7.5.3 Mounting in metal
Flush-mounted in metal
①
Metal
②
Transponders
Note
Damage to the transponder due to improper mounting
To screw the MDS D127 into a suitable thread, use the supplied screw-in tool. This avoids damage to the MDS D127.
172
Figure 7-9 Screw-in aid for mounting the MDS D127
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Transponder
7.5 MDS D127
7.5.4 Technical specifications
Table 7- 12 Technical specifications for MDS D127
Memory size
Memory configuration
• Serial number
• Configuration memory
• Application memory
Storage technology
Memory organization
128 bytes
• 8 bytes (fixed code)
• 8 bytes
• 112 bytes
Data retention (at +40 °C)
MTBF (at +40 °C)
Read cycles
Write cycles (at +40 °C)
• minimum
• Typical
Read/write distance (S g
)
Multitag capability
Power supply
Degree of protection according to EN 60529
Degree of protection according to DIN 40050 Part 9
Shock according to EN 60721-3-7, Class 7M3
Total shock response spectrum, Type II
Vibration-resistant to EN 60721-3-7, Class 7M3
Torsion and bending load
Housing
• Dimensions (D x H)
• Color
• Material
EEPROM
Refer to the RF200 or RF300 system manual, section
"Memory configuration of the ISO tags"
10 years
≥ 2 x 10 6 hours unlimited
•
•
100 000
1 000 000
See section "Field data (Page 35)"
Yes inductive power transmission (without battery)
IP68 1)
IPx9K 2)
100 g 3)
20 g 3) not permitted
•
•
•
M6 x 5 mm (±0.2 mm)
Black
Plastic PA6
Securing
Ambient temperature During operation
During transportation and storage
Screw-in, cemented
-25 ... +100 ℃
-40 ... +125 ℃
Weight
1) 2 hours, 2 m, +20 °C
Approx. 1 g
2) steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C
3) The values for shock and vibration are maximum values and must not be applied continuously.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 173
Transponder
7.5 MDS D127
7.5.5 Dimension drawing
Figure 7-10 Dimensions in mm
174
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
7.6 MDS D139
Transponder
7.6 MDS D139
7.6.1
MDS D139
Characteristics
Characteristics
Field of application Applications in production logistics and in assembly lines subject to high temperatures (up to +220 °C)
Typical application areas:
• Paintshops and their preparatory treatments)
• Primer coat, electrolytic dip area, cataphoresis with the associated drying furnaces
• Top coat area with drying furnaces
• Washing areas at temperatures > 85 °C
• Other applications with higher temperatures
Memory
Read/write range
Mounting on metal
EEPROM 128 bytes gross
112-byte user memory
See Chapter Field data (Page 35).
With spacer; recommended distance from metal ≥ 30 mm
ISO standard ISO 15693
High degree of protection IP68, IPx9K
Material Plastic PPS; silicone-free
7.6.2 Ordering data
Table 7- 13 Ordering data for MDS D139
MDS D139
Table 7- 14 Ordering data for MDS D139 accessory
MDS D139 accessory
Spacer
Quick change holder
Order number
6GT2600-0AA10
Order number
6GT2690-0AA00
6GT2690-0AH00
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 175
Transponder
7.6 MDS D139
7.6.3 Metal-free area
Direct mounting of the MDS D139 on metal is not allowed. A distance of ≥ 30 mm is recommended. This can be achieved using spacers, see Auto-Hotspot.
7.6.4
Figure 7-11 Metal-free area for MDS D139
Note
If the minimum guide values (h) are not observed, a reduction of the field data results. It is possible to mount the MDS with metal screws (M5). This has no tangible impact on the range. It is recommended that a test is performed in critical applications.
Technical specifications
Table 7- 15 Technical data for MDS D139
Memory size
Memory configuration
• Serial number
• Configuration memory
• Application memory
Storage technology
Memory organization
Data retention
MTBF
Read cycles
128 bytes
• 8 bytes (fixed code)
• 8 bytes
• 112 bytes
EEPROM
See MOBY D System Manual,
Chapter 5.1, "Mobile Data Storage Units, Introduction", section "Memory Allocation"
10 years
2 x 10 6 hours
Unlimited
176
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Transponder
7.6 MDS D139
Write cycles at +40 °C
•
• minimum typical
Read/write distance (S g
)
Distance from metal
Multitag capability
Power supply
Degree of protection to EN 60529
• 100 000
• 1.000.000
See Chapter Field data (Page 35).
min. 30 mm (approx. 30% reduction of the field data)
Yes
Inductive power transmission
(without battery)
IP68 1)
IPx9K 2)
50 g Shock according to EN 60721-3-7, Class
7M3
Total shock response spectrum, Type II
Vibration-resistant to EN 60721-3-7, Class
7M3
Torsion and bending load
Enclosure dimensions
• Dimensions (D x H) in mm
• Color
• Material
20 g
Not permissible
• 85 (±0.5) x 15 (-1.0)
• Black
• Plastic PPS, silicone-free
Fixing
Tightening torque
Ambient temperature • During operation
3 x M5 screw 1)
1,5 Nm 4)
-25 °C to +100 °C
+120 °C to +140 °C
+200 °C
+220 °C
5)
Permanent
20% reduction in the limit distance
Tested up to 5000 hours or
3000 cycles
Tested up to 2000 hours or
1500 cycles
• Transport and storage
-40 °C to +100 °C
Weight
1) 2 hours, 2 m, +20 °C
Approx. 50 g
2) steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C
3) For mounting with the spacer (6GT2690-0AA00), use a stainless steel M5 screw to avoid damaging the MDS in high temperatures (expansion coefficient).
4) In higher temperatures (> +80 °C), observe the expansion coefficient of all materials in order to prevent damage to the MDS due to fastening.
5) Note that no processing is possible at temperatures of +140 °C or higher.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 177
Transponder
7.6 MDS D139
7.6.5 Use of the MDS D139 in hazardous areas
The MDS D139 mobile data memory is classed as a piece of simple, electrical equipment and can be operated in Protection Zone 2, Device Group II, Category 3G.
The following requirements of the Directive 94/9/EC are fulfilled:
EN 60079-0 :2006
EN 60079-15 : 2005
EN 61241-0 : 2006
EN 61241-1 : 2004
Identification
II 3 G Ex nA II T2
II 3 D Ex tD A22 IP68 T 220°C
KEMA 09 ATEX 0133 X
Ta: -25 ... +220°C
WARNING
Gefahr durch elektrostatische Entladungen
Potential electrostatic charging hazard
Danger potentiel de charges électrostatiques
178
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Transponder
7.6 MDS D139
Note
Installations- und Betriebsbedingungen für den Ex-Schutzbereich: a) Der Einsatz des Gerätes in der Nähe von stark ladungserzeugenden Prozessen ist untersagt. b) Das Gerät ist mechanisch geschützt zu montieren. c) Die Montage muss auf einem geerdeten, leitenden Untergrund erfolgen. d) Die Reinigung darf nur mit feuchtem Tuch erfolgen.
Installation and operating conditions for hazardous areas: a) Use of the equipment in the vicinity of processes generating high charges is not allowed. b) The equipment must be mechanically protected when installed. c) Installation must be performed on a grounded and conductive mounting surface. d) Cleaning only with a wet cloth
Conditions d'installation et de mise en oeuvre pour la zone de protection Ex : a) L'utilisation de l'appareil près de processus générant de fortes charges est interdite. b) L'appareil doit être monté de manière à être protégé mécaniquement. c) Le montage doit être effectué sur un socle conducteur mis à la terre. d) Nettoyage uniquement avec un chiffon humide
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 179
Transponder
7.6 MDS D139
7.6.6 Dimension drawings
Dimensional drawing of MDS D139
Dimensions in mm
Figure 7-12 Dimensional drawing of MDS D139
Dimensional drawing of spacer 6GT2690-0AA00
180
Figure 7-13 Dimensional drawing of spacer 6GT2690-0AA00
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Dimensional drawing of spacer 6GT2690-0AH00
Transponder
7.6 MDS D139
Figure 7-14 Dimensional drawing of spacer 6GT2690-0AH00
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 181
Transponder
7.7 MDS D160
7.7 MDS D160
7.7.1
MDS D160
Characteristics
Characteristics
Field of application
Memory
Read/write range
Mounting on metal
High resistance
ISO standard
Typical applications are, for example:
• Rented work clothing
• Hotel laundry
• Surgical textiles
• Hospital clothing
• Dirt collection mats
• Clothing for nursing homes/hostels
EEPROM 128 bytes gross
112 bytes net capacity
See Chapter Field data (Page 35).
With spacer:
Recommended distance from metal ≥ 10 mm
Thanks to its rugged packaging, the MDS D160 is a transponder that can be used under extreme environmental conditions. It is washable, heat-resistant and resistant to all chemicals generally used in the laundry process.
ISO 15693
7.7.2 Ordering data
Table 7- 16 Ordering data for MDS D160
MDS D160
Spacer for MDS D160 / MDS D460
Order number
6GT2600-0AB10
6GT2690-0AG00
182
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
7.7.3 Mounting on metal
Mounting on metal
Transponder
7.7 MDS D160 h ≥ 25 mm
Figure 7-15 Mounting of the MDS D160 on metal with spacer
Note
If the minimum guide values (h) are not observed, a reduction of the field data results.
In critical applications, it is recommended that a test is performed.
Flush-mounting
Flush-mounting of the MDS D160 in metal is not permitted!
7.7.4 Technical specifications
Memory size
Memory configuration
• Serial number
• Configuration memory
• Application memory
Storage technology
Memory organization
Protocol
Data retention (at +55 °C)
128 bytes
• 8 bytes (fixed code)
• 8 bytes
• 112 bytes
EEPROM
EEPROM 128 bytes gross
112 bytes net capacity
Only for the RF300:
When using the OPT area, 16 bytes of it must be subtracted in 4 byte blocks
According to ISO 15693
10 years
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 183
Transponder
7.7 MDS D160
MTBF (at +40 °C)
Bulk detection/multitag capability
Data retention
Read cycles
Write cycles at + 40 °C, typical
Write cycles, min.
Read/write distance (S
Distance from metal
Power supply g
)
2 x 10 6 hours
Yes
10 years
Unlimited
1 000 000
100 000
See Chapter Field data (Page 35)
Min. 25 mm (approx. 30% reduction of the field data)
Inductive power transmission
(without battery)
Degree of protection to EN 60529
Shock, tested in accordance with IEC 68-2-27
IP68 (24 hours, 2 m, +20 °C)
40 g
(18 ms; 6 axes; 2000 repeats/h)
Vibration, tested in accordance with IEC 68-2-6 10 g
(10 to 2000 Hz; 3 axes; 2.5 h)
Torsion and bending load Not permissible
Mechanical strength
• Isostatic pressure
• Axial pressure
• Radial pressure
•
•
•
300 bar for 5 min
1000 N for 10 s
1000 N for 10 s
Resistance to chemicals
MDS lifespan
Mechanical design
• Color
• Material
• Dimensions (D x H) in mm
MDS fixing
Ambient temperature During operation
Transport and storage
Weight, approx.
1) No processing possible from +140 °C upwards
All chemicals normally used in the washing process
At least 100 wash cycles
• White
• PPS, pressed, impact-resistant plastic
• 16 (±0.2) x 3.0 (±0.2)
Patch, sew, glue
-25 °C to +85 °C
+125 °C
+175 °C 1)
+220 °C 1)
-25 °C to +100 °C
1 g
Permanent for 1000 hours
(20% reduction in the limit distance)
500 x for 10 minutes
1 x for 30 seconds
184
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Transponder
7.7 MDS D160
Note
• Regeneration time for the MDS D160 between wash cycles must be at least 24 hours
• It is recommended that a test is performed in critical applications.
7.7.5 Dimension drawings
Dimensional drawing of MDS D160
Dimensions in mm
Figure 7-16 Dimensional drawing of MDS D160
Dimensional drawing of spacer
Dimensions in mm
Figure 7-17 Dimensional drawing of spacer
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 185
Transponder
7.8 MDS D165
7.8 MDS D165
7.8.1 Features
MDS D165 (special version) Features
Application area
Memory
Read/write range
ISO standard
The design of the transponder
(self-adhesive label) permits a variety of designs, guaranteeing optimum dimensioning for the widest variety of applications.
From simple identification such as electronic barcode replacement/supplementation, through warehouse and distribution logistics, right up to product identification.
112-byte user memory
15693 with I-Code SLI technology.
7.8.2 Ordering data
Table 7- 17 Ordering data for MDS D165
MDS D165 (special version ISO-CARD)
Type of delivery
Minimum order quantity: 1250 units (5 rolls with 250 units each)
Order No.
6GT2600-1AB00-0AX0
186
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
7.8.3
Transponder
7.8 MDS D165
Technical data
Memory configuration
• Serial number (UID)
• Configuration memory
• AFI/DSFID
• Application memory
Storage technology
Memory organization
Protocol
Data transmission rate
• reading
• writing
Multitag capability
Data retention
Read cycles
Write cycles, min.
Recommended distance to metal
Power supply
Typical read/write distance (Sg)
Degree of protection according to EN 60529
Dimensions
• L x W (in mm)
• Height
Material
• Top
• Inlay
• Antenna
• Bottom
Color
Mounting
Imprinting
• Ambient temperature during operation
• Storage temperature
• 8 bytes (fixed code)
• 6 bytes
• 2 bytes
• 112 bytes
EEPROM
4 bytes, block by block according to ISO 15693
• approx. 3.5 ms/byte
• approx. 9.5 ms/byte
Yes
10 years
Unlimited
100 000
25 mm (approx. 30% reduction of the field data)
Inductive power transmission (without battery)
See Chapter Field data (Page 35)
IP65
• 86 x 54
• approx. 0.3 mm
• PET plastic (label material)
• PET plastic (carrier material)
• Aluminum
• Double-sided transfer adhesive on silicon paper
White
Single-sided adhesive (self-adhesive label)
Yes, (heat transfer method)
• -25 °C to +85 °C
• +20 °C to +30 °C (the storage period is 2 years, determined by durability of the adhesive)
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 187
Transponder
7.9 MDS D200
7.8.4 Dimension drawing
Dimensions in mm
Figure 7-18 Dimension drawing of MDS D165
7.9 MDS D200
7.9.1 Features
MDS D200 (special version) Features
Application area
Memory
Read/write range
Mounting on metal
ISO standard
From simple identification such as electronic barcode replacement/supplementation, through warehouse and distribution logistics, right up to product identification.
256-byte user memory
See Chapter Field data (Page 35).
Recommended distance from metal ≥ 30 mm
15693 with Tag-it HFI technology
7.9.2 Ordering data
Table 7- 18 Ordering data for MDS D200
MDS D200 (special version ISO-CARD)
Order No.
6GT2600-1AD00-0AX0
188
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
7.9.3 Mounting on metal
Mounting on metal
h ≥ 20 mm
①
Data memory
②
Metal
③
Non-metal
Figure 7-19 Mounting of the MDS D200 on metal with spacer
Transponder
7.9 MDS D200
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 189
Transponder
7.9 MDS D200
Flush-mounting
7.9.4 a ≥ 20 mm h ≥ 20 mm
①
Data memory
②
Metal
③
Non-metal
Figure 7-20 Flush-mounting of MDS D200 in metal with spacer
Note
If the minimum guide values (h) are not observed, a reduction of the field data results.
Technical data
Memory configuration
• Serial number
• Application memory
Storage technology
Memory organization
Protocol
Data retention (at +25 °C)
MTBF (at +25 °C)
• 8 bytes (fixed code)
• 256 bytes
EEPROM
4 bytes, block by block according to ISO 15693
10 years
2 x 105 hours
190
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
7.9.5
Transponder
7.9 MDS D200
• Read cycles
• Write cycles, min.
• Write cycles, typical
• Unlimited
• 100 000
• 1 000 000
Read/write distance (Sg)
Recommended distance to metal
Multitag capability
See Chapter Field data (Page 35)
25 mm (approx. 30% reduction of the field data)
Yes
Power supply Inductive power transmission (without battery)
Degree of protection according to EN 60529 IP67
Vibration
Torsion and bending load
ISO 10373/ISO 7810
ISO 10373/ISO 7816-1
Mechanical design
• Color
• Material
• Dimensions (L x W x H in mm)
Laminated plastic card, printable on both sides
• White
• PET
• 85 x 54 x 0.8
Mounting
Ambient temperature
• Operation
• Transport and storage
Weight
Adhesive, fixing lug
• -20 °C to +60 °C
• -20 °C to +60 °C approx. 5 g
Dimension drawing
Dimensions in mm
Figure 7-21 Dimension drawing of MDS D200
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 191
Transponder
7.10 MDS D261
7.10 MDS D261
7.10.1 Features
MDS D261 (special version) Features
Application area
Memory
Read/write range
ISO standard
The design of the transponder
(self-adhesive label) permits a variety of designs, guaranteeing optimum dimensioning for the widest variety of applications.
From simple identification such as electronic barcode replacement/supplementation, through warehouse and distribution logistics, right up to product identification.
256-byte user memory
15693 with Tag-it HFI technology.
7.10.2 Ordering data
Table 7- 19 Ordering data for MDS D261
MDS D261
Type of delivery
Minimum order quantity: 1250 units (5 rolls with 250 units each)
Order No.
6GT2600-1AA00-0AX0
192
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
7.10.3
Transponder
7.10 MDS D261
Technical data
Memory configuration
• Serial number
• AFI/DSFID
• Application memory
Storage technology
Memory organization
Protocol
Data transmission rate
• reading
• writing
Multitag capability
Data retention
Read cycles
Write cycles, min.
Recommended distance to metal
Power supply
Typical read/write distance
Degree of protection according to EN 60529
Dimensions
• L x W (in mm)
• Height
Material
• Top
• Inlay
• Antenna
• Bottom
Color
Mounting
Imprinting
• Ambient temperature during operation
• Storage temperature
Type of delivery
• 8 bytes (fixed code)
• 2 bytes
• 256 bytes
EEPROM
4 bytes, block by block according to ISO 15693
• approx. 3.5 ms/byte
• approx. 9.5 ms/byte
Yes
10 years
Unlimited
100 000
25 mm (approx. 30% reduction of the field data)
Inductive power transmission (without battery)
See Chapter Field data (Page 35)
IP65
• 55 x 55
• approx. 0.3 mm
• PET plastic (label material)
• PET plastic (carrier material)
• Aluminum
• Double-sided transfer adhesive on silicon paper
White
Single-sided adhesive (self-adhesive label)
Yes (heat transfer method)
• -25 °C to +85 °C
• +20 °C to +30 °C (the storage period is 2 years, determined by durability of the adhesive)
Minimum order quantity 1250 units
(5 rolls with 250 units each)
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 193
Transponder
7.10 MDS D261
7.10.4 Dimension drawing
Dimensions in mm
Figure 7-22 Dimension drawing of MDS D261
194
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
7.11 MDS D324
7.11.1
MDS D324
Characteristics
Characteristics
Field of application
Memory
Read/write range
Mounting on metal
High resistance
ISO standard
7.11.2 Ordering data
Table 7- 20 Ordering data MDS D324
MDS D324
Order number
6GT2600-3AC00
Transponder
7.11 MDS D324
Production and distribution logistics and product identification
EEPROM 1024 bytes gross
992 bytes net capacity
See Chapter Field data (Page 35).
Not possible:
Recommended distance from metal
≥ 25 mm
Can also be used in harsh environments under extreme environmental conditions (e.g. with higher temperature load).
ISO 15693
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 195
Transponder
7.11 MDS D324
7.11.3 Metal-free area h ≥ 25 mm
Figure 7-23 Mounting of the MDS D324 on metal with spacer h a
≥ 25 mm
≥ 25 mm
Figure 7-24 Flush-mounting of MDS D324 in metal with spacer
Note
If the minimum guide values (h) are not observed, a reduction of the field data results. It is possible to mount the MDS with metal screws (M3 countersunk head screws). This has no tangible impact on the range.
196
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
7.11.4
Transponder
7.11 MDS D324
Technical specifications
Table 7- 21 Technical data MDS D324
Memory size
Memory configuration
• Serial number
• Configuration memory
• Manufacturer data
Storage technology
Memory organization
Protocol
Data retention (at +40 °C)
MTBF (at +40 °C)
Read cycles
Write cycles, typical
Write cycles, min.
Read/write distance (S
Distance from metal
Multitag capability
Anti-collision speed
Power supply g
)
Degree of protection to EN 60529
Shock resistant to EN 60721-3-7, Class 7M3 total shock response spectrum, type II
Vibration-resistant to EN 60721-3-7, Class
7M3
Torsion and bending load
Enclosure
• Dimensions (D x H) in mm
• Color
• Material
Fixing
Tightening torque at +20 °C
1024 bytes
• 8 bytes (fixed code)
• 1008 bytes
• 8 bytes
EEPROM
1024 EEPROM/gross
992 net capacity
When using the OPT area, 16 bytes of it must be subtracted in 4 byte blocks according to ISO 15693
10 years
≥ 1.5 x 10 6 hours
Unlimited
1 000 000
100 000
See Chapter Field data (Page 35)
Min. 25 mm (approx. 30% reduction of the field data)
Yes
Approx. 20 transponders/s simultaneously identifiable
Inductive power transmission
(without battery)
IP67
100 g
20 g
Not permissible
• 27(±-0,2) x 4(±0.2)
• Black
• Epoxy casting resin
Adhesive, M3 screw
≤ 1 Nm
(at high temperatures, the expansion coefficients of the materials used must be taken into account)
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 197
Transponder
7.11 MDS D324
Ambient temperature
• Operation
• During transportation and storage
Weight, ca.
7.11.5 Dimension drawing
• -25 °C to +125 °C
• -40 °C to +150 °C
5 g
Dimensions in mm
Figure 7-25 Dimension drawing of MDS D324
198
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
7.12 MDS D339
Transponder
7.12 MDS D339
7.12.1
MDS D339
Characteristics
Characteristics
Field of application
Memory
Read/write range
Mounting on metal
ISO standard
High degree of protection
Material
Applications in production automation with high temperature demands (up to +220 °C)
Typical application areas:
• Paintshops and their preparatory treatments
• Primer coat, electrolytic dip area, cataphoresis with the associated drying furnaces
• Top coat area with drying furnaces
• Washing areas at temperatures > 85 °C
• Other applications with higher temperatures
1024 bytes of EEPROM/gross
992 bytes of user memory
See Chapter Field data (Page 35).
With spacer; recommended distance from metal ≥ 30 mm
ISO 15693
IP68, IPx9K
Plastic PPS; silicone-free
7.12.2 Ordering data
Table 7- 22 Ordering data for MDS D339
Transponder
MDS D339
Order number
6GT2600-3AA10
Table 7- 23 Ordering data for MDS D339 accessories
Accessories
Spacers
Quick change holder
Order number
6GT2690-0AA00
6GT2690-0AH00
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 199
Transponder
7.12 MDS D339
7.12.3 Mounting on metal
Direct mounting of the MDS D339 on metal is not allowed. A distance of ≥ 30 mm is recommended. This can be achieved using spacers, see Auto-Hotspot. a = ∅ 85 mm h ≥ 30 mm
Figure 7-26 MDS D339: Mounting on metal
Note
If the minimum guide values (h) are not observed, a reduction of the field data results. It is possible to mount the MDS with metal screws (M5). This has no tangible impact on the range. It is recommended that a test is performed in critical applications.
200
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
7.12.4
Transponder
7.12 MDS D339
Mounting in metal
It is possible to mount the MDS D339 in metal. With large antennas, for example ANT D5, this leads to a reduction of ranges. a = 100 mm h = 30 mm
Figure 7-27 MDS D339: Mounting in metal
7.12.5 Technical specifications
Table 7- 24 Technical specifications of MDS D339
Memory size
Memory configuration
• Serial number
• Configuration memory
• Application memory
Storage technology
Memory organization
Data retention (at +40 °C)
MTBF
Read cycles
Write cycles (at +40 °C)
• minimum
• typical
Read/write distance (S g
)
Distance from metal
Multitag capability
Power supply
1024 bytes
• 8 bytes (fixed code)
• 24 bytes
• 992 bytes
EEPROM
Refer to the MOBY D system manual or RF300 section "Memory configuration of the ISO tags"
10 years
2 x 10 6 hours
Unlimited
• 100,000
• 1,000,000
See table Field data (Page 35).
min. 30 mm (approx. 30% reduction of the field data)
Yes
Inductive power transmission
(without battery)
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 201
Transponder
7.12 MDS D339
Degree of protection to EN 60529
Shock according to EN 60721-3-7, Class 7M3
Total shock response spectrum, Type II
Vibration-resistant to EN 60721-3-7, Class 7M3
Torsion and bending load
Enclosure dimensions
• Dimensions (D x H)
• Color
• Material
IP68 1)
IPx9K 2)
50 g
20 g
Not permissible
• 85 mm (±0.5) x 15 mm (-1.0)
• Black
• Plastic PPS, silicone-free
Fixing
Tightening torque
Ambient temperature
• In operation
1 x stainless steel screw, thread M5 3)
1.5 Nm 4)
-25 °C to +100 °C Permanent
+120 °C to +140 °C
+25 °C ... +200 °C
+25 °C ... +220 °C
-40 °C to +100 °C
5)
5)
20% reduction in the limit distance
Up to 6000 cycles tested
Up to 2000 cycles tested
• Transport and storage
Weight
1) 2 hours, 2 m, +20 °C
2) steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C
Approx. 50 g
3) See chapter Mounting options
4) Max. torque when securing the MDS. When used in higher temperatures (> +80 °C), remember the expansion coefficients of all materials (see chapter Mounting options).
5) Note that no processing is possible at temperatures of +140 °C or higher.
7.12.6 Use of the MDS D339 in hazardous areas
The MDS D339 mobile data memory is classed as a piece of simple, electrical equipment and can be operated in Protection Zone 2, Device Group II, Category 3G.
The following requirements of the Directive 94/9/EC are fulfilled:
EN 60079-0:2006, EN 60079-15:2005, EN 61241-0:2006, EN 61241-1:2004
202
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Identification
Transponder
7.12 MDS D339
II 3 G Ex nA II T6
Ii 3 D Ex tD A22 IP68 T 210°C
KEMA 09 ATEX 0133 X
WARNING
Gefahr durch elektrostatische Entladungen
Potential electrostatic charging hazard
Danger potentiel de charges électrostatiques
Note
Installations- und Betriebsbedingungen für den Ex-Schutzbereich: a) Der Einsatz des Gerätes in der Nähe von stark ladungserzeugenden Prozessen ist untersagt. b) Das Gerät ist mechanisch geschützt zu montieren. c) Die Montage muss auf einem geerdeten, leitenden Untergrund erfolgen. d) Die Reinigung darf nur mit feuchtem Tuch erfolgen.
Installation and operating conditions for hazardous areas: a) Use of the equipment in the vicinity of processes generating high charges is not allowed. b) The equipment must be mechanically protected when installed. c) Installation must be performed on a grounded and conductive mounting surface. d) Cleaning only with a wet cloth
Conditions d'installation et de mise en oeuvre pour la zone de protection Ex : a) L'utilisation de l'appareil près de processus générant de fortes charges est interdite. b) L'appareil doit être monté de manière à être protégé mécaniquement. c) Le montage doit être effectué sur un socle conducteur mis à la terre. d) Nettoyage uniquement avec un chiffon humide
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 203
Transponder
7.12 MDS D339
7.12.7
MDS D339
Dimensional drawing
Dimensions in mm
Figure 7-28 Dimension drawing of the MDS D339
Spacers 6GT2690-0AA00
204
Figure 7-29 Dimension drawing of spacers 6GT2690-0AA00
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Spacers 6GT2690-0AH00
Figure 7-30 Dimension drawing of spacers 6GT2690-0AH00
Transponder
7.12 MDS D339
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 205
Transponder
7.13 MDS D400
7.13 MDS D400
7.13.1
MDS D400
Features
Features
Area of application
Memory
Reading / writing range
ISO standard
Material
Simple identification such as electronic barcode replacement/supplements, from warehouse and distribution logistics right through to product identification.
FRAM 2048 bytes gross
2000 bytes net
See section "Field data (Page 35)"
Based on ISO standard 15693
PVC
7.13.2 Ordering data
Table 7- 25 Ordering data of MDS D400
Product
MDS D400
Table 7- 26 Accessories for MDS D400
Product
Spacer in conjunction with fixing pocket
(6GT2190-0AB00)
Fixing pocket for spacer
Fixing pocket
Order number
6GT2600-4AD00
Order number
6GT2190-0AA00
6GT2190-0AB00
6GT2390-0AA00
206
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
7.13.3 Mounting on metal
Mounting on metal
It is possible to mount the MDS D400 on metal.
Transponder
7.13 MDS D400 h ≥ 20 mm
①
Transponder
②
Metal
③
Non-metal
Figure 7-31 Mounting of the MDS D400 on metal with spacer
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 207
Transponder
7.13 MDS D400
Flush-mounted in metal
a ≥ 20 mm h ≥ 20 mm
①
Transponder
②
Metal
③
Non-metal
Figure 7-32 Flush-mounting of MDS D400 in metal with spacer
Note
If the minimum guide values (h) are not observed, this will result in a reduction of the field data.
7.13.4 Technical specifications
Table 7- 27 Technical data MDS 400
Memory size
Memory configuration
• Serial number
• Configuration memory
• Application memory
Storage technology
Memory organization
208
2048 bytes
• 8 bytes (fixed code)
• 40 bytes
• 2000 bytes
FRAM
Refer to the MOBY D system manual, RF200 or RF300, section "Memory configuration of the ISO tags"
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Transponder
7.13 MDS D400
Data retention (at +40 °C)
MTBF (at +40 °C)
Read cycles
Write cycles (at +40 °C)
Read/write distance (S g
)
Distance from metal
Multitag capability
Power supply
Degree of protection according to EN 60529
Vibration-resistant to EN 60721-3-7, Class 7M3
Torsion and bending load
Housing
• Dimensions (L x W x H)
• Color
• Material
10 years
≥ 2 x 10 6 hours
> 10 10
> 10 10
See section "Field data (Page 35)"
≥ 20 mm
Yes inductive power transmission (without battery)
IP67
ISO 10373 / ISO 7810 1)
ISO 10373/ISO 7816-1
Laminated plastic card, printable
• 85.6 (±0.3) × 54 (±0.2) × 0.8 (±0.05) mm
• White
• PVC
Securing
Ambient temperature During operation
During transportation and storage
Adhesive, fixing lug
-25 ... +60 ℃
-25 ... +60 ℃
Weight Approx. 5 g
1) The values for vibration are maximum values and must not be applied continuously.
7.13.5 Dimension drawing
Figure 7-33 Dimensional drawing MDS D400 (dimensions in mm)
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 209
Transponder
7.14 MDS D421
7.14 MDS D421
7.14.1
MDS D421
Characteristics
Characteristics
Field of application
Memory
Read/write range
Mounting
High resistance
Standard
7.14.2 Ordering data
Table 7- 28 Ordering data of MDS D421
MDS D421
Order number
6GT2600-4AE00
The MDS D421 is designed for tool coding in accordance with DIN 69873.
It can be used wherever small data carriers and exact positioning are required, e.g. tool identification, workpiece holders
FRAM 2048 bytes gross
2000 bytes net
See Chapter Field data (Page 35).
Flush-mounted in and on metal
Rugged packaging of the MDS D421; can therefore also be used in a harsh industrial environment without problem
Oriented according to ISO standard 15693
210
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
7.14.3 Mounting on metal
Mounting on metal
Flush-mounting
Figure 7-34 Mounting of MDS D421 on metal
Figure 7-35 Mounting of MDS D421 in metal
Transponder
7.14 MDS D421
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 211
Transponder
7.14 MDS D421
Flush-mounting of MDS D421 in metal with tools
Figure 7-36 Flush-mounting of MDS D421 in metal with tools b
1 d
1
0.5 x 45°
10 (-0.04.. -0.13) t
1
4.5 (-0... -0,1)
All dimensions in mm b
2 d
2 t
2
0.3 x 45° or R 0.3
10 (+0.09... 0)
4.6 (+0.2... 0)
Note
The MDS should not protrude out of the locating hole; it must be flush with the outside contour.
The mounting instructions of the MDS and the conditions associated with the application
(e.g. peripheral speed, temperature, and use of coolant) must be observed during the installation.
Mounting information for adhesion
● Drill installation hole
● The adhesive surfaces must be dry, free from dust, oil, stripping agents and other impurities
● Apply adhesive according to the manufacturer's processing instructions
● Press in MDS D421 using your finger; antenna side to the outside (see figure "Flushmounting of MDS D421 in metal with tools")
● Remove residues of adhesive
● Allow to cure according to the manufacturer's instructions
● Flush-mounting of MDS D421 in metal with tools
212
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Installation examples
Figure 7-37 Installation example of MDS D421 in a steep cone
Transponder
7.14 MDS D421
Figure 7-38 Installation example of MDS D421 in a stud bolt
7.14.4 Technical specifications
Table 7- 29 Technical data of MDS D421
Memory size
Memory configuration
• Serial number
• Configuration memory
• Application memory
2048 bytes
•
•
•
8 bytes (fixed code)
40 bytes
2000 bytes
Storage technology
Memory organization
FRAM
2048 bytes gross
2000 bytes net
ISO 15693 Protocol
MTBF (at +40 °C)
Read cycles
Write cycles at +40 °C
Bulk detection/multitag capability
Data retention (at +40°C)
Read/write distance (S
Direction-dependent
Power supply g
)
2.5 x 10 6 hours
Unlimited
> 10
Yes
10 typ.
10 years
See Chapter Field data (Page 35)
No
Inductive power transmission (without battery)
Vibration, tested in accordance with IEC 68-2-6 20 g 1)
Shock, tested in accordance with IEC 68-2-27 100 g 1)
Torsion and bending load Not permissible
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 213
Transponder
7.14 MDS D421
MDS fixing
Degree of protection
• In accordance with EN 60529
• In accordance with DIN 40050 Part 9
Enclosure
• Color
• Material
• Dimensions (D x H) in mm
(dimensions and tolerances in accordance with DIN 69873)
Adhesion 2) ; e.g. Araldit AW2101/HW2951 or 2021;
UHU-Plus endfest 300
•
•
IP67
IPx9K 3)
Pressed, impact-resistant plastic
• Black
• Epoxy casting resin
• 10 x 4.5
(chamfer underneath 0.5 x 45°)
Ambient temperature During operation –25 °C to +85 °C
Transport and storage –40 °C to +100 °C
Weight, approx. 4 g
1) The values for shock and vibration are maximum values and must not be applied continuously.
2) The manufacturer's processing instructions must be observed.
3) steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C
7.14.5 Dimension drawing
214
Dimensions in mm
Figure 7-39 Dimension drawing of MDS D421
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
7.15 MDS D422
7.15.1
MDS D422
Characteristics
Characteristics
Field of application
Memory
Read/write range
ISO standard
7.15.2 Ordering data
Table 7- 30 Ordering data of MDS D422
MDS D422
A screw-in aid is included in the scope of supply per packaging unit
Identification of metallic workpiece holders, workpieces or containers
FRAM 2048 bytes gross
2000°bytes net
See Chapter Field data (Page 35).
Oriented according to ISO standard 15693
Order number
6GT2600-4AF00
Transponder
7.15 MDS D422
7.15.3 Mounting on metal
Flush-mounting
Figure 7-40 Mounting of MDS D422 in metal
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 215
Transponder
7.15 MDS D422
Mounting information for screws
You can screw the transponder into a pre-drilled threaded hole using the screw-in aid.
Mounting information for adhesion
● Drill installation hole
● The adhesive surfaces must be dry, free from dust, oil, stripping agents and other impurities
● Apply adhesive according to the manufacturer's processing instructions
● Press in MDS D422 using your fingers; with antenna side to the outside (see Fig.)
● Remove residues of adhesive
● Allow to cure according to the manufacturer's instructions
● Flush-mounting of MDS D422 in metal with tools
7.15.4 Technical specifications
Product type designation
Memory size
Memory configuration
• Serial number
• Configuration memory
• Application memory
Storage technology
Memory organization
Protocol
Data retention (at +40 °C)
MTBF (at +40 °C)
Data transmission rate
Reading and writing
Bulk detection/multitag capability
Read cycles
Write cycles
(at +40 °C, typical)
Read/write distance (S g
)
MDS D422
2048 bytes
• 8 bytes (fixed code)
• 40 bytes
• 2000 bytes
6GT2600-4AF00
FRAM
FRAM 2048 bytes / gross
2000 bytes net
Only for the RF300:
When using the OPT area, 16 bytes of it must be subtracted in 8 byte blocks
ISO 15693
10 years
2 x 10 6 h approx. 2 ms/byte
Yes unlimited
>10 10
See section Field data (Page 35)
216
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Transponder
7.15 MDS D422
Power supply
Degree of protection to EN 60529
6GT2600-4AF00
Inductive power transmission
(without battery)
IP68 1)
Shock, tested in accordance with IEC 68-2-27 50 g 2)
Vibration, tested in accordance with IEC 68-2-6 20 g 2)
Torsion and bending load
Housing not permitted
• Color
• Material
• Dimensions (D × pitch × H)
• Black, silver
• Plastic PA 6.6 GF; brass nickel plated
• M20 × 1 mm × 6 (± 0.2) mm
Transponder attachment
Ambient temperature
• During operation
• During transportation and storage
Screw in (M20 1 mm)
Cement in
•
•
-25 °C ... +85 °C
-40 °C ... +100 °C
Weight, approx.
1) 2 hours, 2 m, +20 °C
13 g
2) The values for shock and vibration are maximum values and must not be applied continuously.
7.15.5 Dimension drawing
Dimensions in mm
Figure 7-41 Dimensional drawing of MDS D422
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 217
Transponder
7.16 MDS D423
7.16 MDS D423
7.16.1
MDS D423
Characteristics
Characteristics
Field of application
Memory
Installation
Identification of metallic workpiece holders, workpieces or containers, production automation
FRAM 2048 bytes gross
2000 bytes net
Can be mounted in and on metal
7.16.2 Ordering data
Table 7- 31 Ordering data of MDS D423
MDS D423
Order number
6GT2600-4AA00
7.16.3 Mounting on metal
Mounting on metal
Direct mounting of the MDS D423 on metal is possible.
218
Figure 7-42 Mounting the MDS D423 on metal
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Flush-mounted in metal
It is possible to mount the MDS D423 in metal.
Transponder
7.16 MDS D423 a ≥ 10 mm
Figure 7-43 Flush-mounting of MDS D423 in metal
7.16.4 Technical specifications
Table 7- 32 Technical specifications of MDS D423
Memory size
Memory configuration
• Serial number
• Configuration memory
• Application memory
Storage technology
Memory organization
Report
Data retention (at +40 °C)
MTBF (at +40 °C)
Read cycles
Write cycles (at +40 °C)
Read/write distance (S g
)
Mounting on metal
Mounting in metal
Power supply
2048 bytes
• 8 bytes (fixed code)
• 40 bytes
• 2000 bytes
FRAM
FRAM, 2048 bytes gross
2000 bytes net
(when using the OPT area, 16 bytes of it must be subtracted in 8 byte blocks)
ISO 15693
10 years
2 x 10 6 hours
Unlimited
> 10 10
See section "Field data (Page 35)."
Yes yes, with 10 mm clearance all round inductive power transmission (without battery)
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 219
Transponder
7.16 MDS D423
Degree of protection to EN 60529
Pressure resistance
IP68 1)
IPx9K 2)
• low pressure resistant 3)
• high pressure resistant (see degree of protection IPx9K)
Shock according to EN 60721-3-7, Class 7M3
Total shock response spectrum, Type II
Vibration-resistant to EN 60721-3-7, Class 7M3
Torsion and bending load
Enclosure
•
•
•
Dimensions (D x H)
Color
Material
Fixing
Tightening torque
Ambient temperature
• During operation
• Transport and storage
50 g 4)
20 g 4)
Not permissible
• 30 mm (+0.2/-0.5) x 8 mm (-0.5)
• Black
• Plastic PPS, silicone-free
Countersunk screw, thread M4
≤ 1 Nm
•
•
-25 °C to +85 °C
-40 °C to +100 °C
5)
Weight
1) 2 hours, 2 m, +20 °C
2) steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C
Approx. 10 g
3) vacuum dryer: up to 20 mbar
4) The values for shock and vibration are maximum values and must not be applied continuously.
5 ) To prevent it loosening, secure the screw with screw locking varnish.
7.16.5 Dimensional drawing
220
Dimensions in mm
Figure 7-44 Dimension drawing for MDS D423
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
7.17 MDS D424
7.17.1
MDS D424
Characteristics
Characteristics
Field of application
Memory
Read/write range
Mounting on metal
High resistance
Standard
7.17.2 Ordering data
Table 7- 33 Ordering data of MDS D424
MDS D424
Order number
6GT2600-4AC00
7.17.3 Mounting on metal
Mounting on metal
Transponder
7.17 MDS D424
Production and distribution logistics as well as in assembly and production lines
FRAM 2048 bytes gross
2000 bytes net
See Chapter Field data (Page 35).
Not possible:
Recommended distance from metal ≥ 25 mm
Can also be used in a harsh industrial environment without problem
Oriented according to ISO standard 15693 h ≥ 25 mm
Figure 7-45 Mounting of the MDS D424 on metal with spacer
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 221
Transponder
7.17 MDS D424
Flush-mounting
h a
≥ 25 mm
≥ 25 mm
Figure 7-46 Flush-mounting of MDS D424 in metal with spacer
Note
If the minimum guide values (h) are not observed, a reduction of the field data results. It is possible to mount the MDS with metal screws (M3 countersunk head screws). This has no tangible impact on the range.
7.17.4 Technical specifications
Table 7- 34 Technical data of MDS D424
Memory size
Memory configuration
• Serial number
• Configuration memory
• Application memory
Storage technology
Memory organization
Protocol
Data retention (at +40 °C)
MTBF (at +40 °C)
Read cycles
Write cycles (at +40 °C)
Read/write distance (S g
)
Distance from metal
Multitag capability
2048 bytes
• 8 bytes (fixed code)
• 40 bytes
• 2000 bytes
FRAM
2048 bytes gross
2000 bytes net
ISO 15693
10 years
≥ 1.5 x 10 6 hours
Unlimited
> 10 10
See Chapter Field data (Page 35)
Min. 25 mm (ca. 30% reduction of the field data)
Yes
222
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Transponder
7.17 MDS D424
Power supply
Degree of protection to EN 60529
Shock according to EN 60721-3-7, Class 7M3
Total shock response spectrum, Type II
Vibration-resistant to EN 60721-3-7, Class
7M3
Torsion and bending load
Enclosure
• Color
• Material
• Dimensions (D x H) in mm
Fixing
Tightening torque at +20 °C
Ambient temperature
• During operation
• Transport and storage
Inductive power transmission
(without battery)
IP67
100 g
20 g
•
1)
1)
Not permissible
Black
• Epoxy casting resin
• 27(±0.2) x 4(±0.2)
M3 screw, adhesive
≤ 1 Nm
•
•
-25 °C to +85 °C
-40 °C to +100 °C
Weight, approx. 5 g
1) The values for shock and vibration are maximum values and must not be applied continuously.
7.17.5 Dimension drawing
Dimensions in mm
Figure 7-47 Dimension drawing of MDS D424
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 223
Transponder
7.18 MDS D425
7.18 MDS D425
7.18.1
MDS D425
Characteristics
Characteristics
Field of application
Memory
Read/write range
Mounting on metal
High resistance
Standard
7.18.2 Ordering data
Table 7- 35 Ordering data of MDS D425
MDS D425
Order number
6GT2600-4AG00
Compact and rugged ISO transponder; suitable for screw mounting
Use in assembly and production lines in the powertrain sector; ideal for mounting on motors, gearboxes, and workpiece holders
FRAM 2048 bytes gross
2000 bytes net
See section "Field data (Page 35)".
Yes
Rugged packaging of the MDS D425; can therefore also be used under extreme environmental conditions without problem
Oriented according to ISO-15693
224
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
7.18.3 Application example of MDS D425
Transponder
7.18 MDS D425
Figure 7-48 Application example
7.18.4 Technical specifications
Table 7- 36 Technical data of MDS D425
Memory size
Memory configuration
• Serial number
• Configuration memory
• Application memory
Storage technology
Memory organization
Protocol
Data retention (at +40 °C)
MTBF
Data rate read/write
Bulk detection/multitag capability
Read cycles
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
2048 bytes
• 8 bytes (fixed code)
• 40 bytes
• 2000 bytes
FRAM
2048 bytes gross
2000 bytes net when using the OPT area, 16 bytes of this must be subtracted in 8 byte blocks
ISO 15693
10 years
≥ 2 ° 10 6 h approx. 2 ms/byte
Yes unlimited
225
Transponder
7.18 MDS D425
Write cycles at +40 °C, typical
Read/write distance (S g
)
Distance from metal
Power supply
Degree of protection according to EN 60529
Shock, tested in accordance with IEC 68-2-27
Vibration, tested in accordance with IEC 68-2-6
Torsion and bending load
Housing
• Color
• Material
• Dimensions (D x H)
MDS fixing
Ambient temperature
• During operation
• During transportation and storage
> 10 10
See section "Field data (Page 35)."
Can be mounted on metal
Inductive power transmission
(without battery)
IP68 1)
IPx9K 2)
50 g 3)
20 g 3) not permitted
• Black
• Plastic PA 6.6 GF; thread: Stainless steel
• Wrench size 22 mm x 10 mm (±1) (without thread), thread M6
Screws, tightening torque (at room temperature) ≤ 6 Nm
• -25 °C ... +85 °C
• -40 °C ... +125 °C
Weight
1) 2 hours, 2 m, +20 °C
2) steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C
Approx. 35 g
3) The values for shock and vibration are maximum values and must not be applied continuously.
Note
It is recommended that a test is performed in critical applications.
226
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
7.18.5 Dimension drawing
Dimensions in mm
Figure 7-49 Dimension drawing of MDS D425
Transponder
7.18 MDS D425
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 227
Transponder
7.19 MDS D426
7.19 MDS D426
7.19.1
MDS D426
Characteristics
Characteristics
Field of application
Memory
Read/write range
Standard
Compact and rugged ISO transponder; suitable for identification of transport units in production-related logistics; can also be deployed in harsh conditions
FRAM 2048 bytes gross
2000°bytes net
See Chapter Field data (Page 35)
Oriented according to ISO standard 15693
7.19.2 Ordering data
Table 7- 37 Ordering data of MDS D426
MDS D426
Order number
6GT2600-4AH00
7.19.3 Technical specifications
Product type designation
Memory size
Memory configuration
• Serial number
• Configuration memory
• Application memory
Storage technology
Memory organization
228
Protocol
MDS D426
2048 bytes
• 8 bytes (fixed code)
• 40 bytes
• 2000 bytes
6GT2600-4AH00
FRAM
FRAM 2048 bytes / gross
2000 bytes net
Only for RF300:
When using the OPT area, 16 bytes of it must be subtracted in 8 byte blocks
ISO 15693
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Transponder
7.19 MDS D426
Data retention (at +40 °C)
MTBF
Data transmission rate for read and write
Bulk detection/multitag capability
Read cycles
10 years
≥ 2 ° 10 6 h approx. 2 ms/byte
Yes unlimited
6GT2600-4AH00
Write cycles (at +40 °C, typical)
Read/write distance (S g
)
Distance from metal
Power supply
> 10 10
See section Field data (Page 35)
≥ 25 mm (approx. 25 % reduction of the field data)
Inductive power transmission
(without battery)
IP68 1) Degree of protection according to EN 60529
Shock, tested in accordance with IEC 68-2-27 50 g 2)
Vibration, tested in accordance with IEC 68-2-6 20 g 2)
Torsion and bending load
Housing
• Color not permitted
• Black
• Material
• Dimensions (D × H)
• Attachment hole (D)
• Plastic PA 6.6 GF
• 50 (±0.3) × 3.6 (±0.2) mm
• 5.1 (±0.2) mm
MDS fixing
Ambient temperature
• During operation
• During transportation and storage
M4 screws, tightening torque (at room temperature) ≤ 1 Nm, adhesive
• -25 °C ... +85 °C
• -40 °C ... +100 °C
Weight
1) 2 hours, 2 m, +20 °C
Approx. 13 g
2) The values for shock and vibration are maximum values and must not be applied continuously.
Note
It is recommended that a test is performed in critical applications.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 229
Transponder
7.19 MDS D426
7.19.4 Dimension drawing
Dimensions in mm
Figure 7-50 Dimension drawing of MDS D426
230
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
7.20 MDS D428
7.20.1
MDS D428
Characteristics
Characteristics
Field of application
Memory
Read/write range
Mounting on metal
High resistance
Standard
7.20.2 Ordering data
Table 7- 38 Ordering data of MDS D428
MDS D428
Order number
6GT2600-4AK00
Transponder
7.20 MDS D428
Compact and rugged ISO transponder; suitable for screw mounting
Use in assembly and production lines in the powertrain sector
FRAM 2048 bytes gross
2000 bytes net
See Chapter Field data (Page 35).
Yes
Rugged packaging of the MDS D428; can therefore also be used under extreme environmental conditions without problem
Oriented according to ISO-15693
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 231
Transponder
7.20 MDS D428
7.20.3 Application example of MDS D428
Figure 7-51 Application example
7.20.4
232
Technical specifications
Table 7- 39 Technical data of MDS D428
Memory size
Memory configuration
• Serial number
• Configuration memory
• Application memory
Storage technology
Memory organization
Protocol
Data retention (at +40 °C)
Bulk detection/multitag capability
Read cycles
Write cycles at +40 °C, typical
Read/write distance (S g
)
Distance from metal
Power supply
2048 bytes
• 8 bytes (fixed code)
• 40 bytes
• 2000 bytes
FRAM
2048 bytes gross
2000 bytes net
ISO 15693
10 years
Yes unlimited
> 10 10
See section Field data (Page 35)
Can be mounted on metal
Inductive power transmission
(without battery)
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Transponder
7.20 MDS D428
Degree of protection according to EN 60529
Shock, tested in accordance with IEC 68-2-27
IP68 1)
IPx9K 2)
50 g 3)
Vibration, tested in accordance with IEC 68-2-6 20 g 3)
Torsion and bending load not permitted
Housing
• Color
• Material
• Dimensions (D x H) in mm
•
•
Black
• Plastic PA 6.6 GF; thread: Stainless steel
18(±1) x 20(±1) (without thread), thread M8
MDS fixing
Ambient temperature
• During operation
• During transportation and storage
Screws, tightening torque (at room temperature) ≤
8 Nm
• -25 °C to +85 °C
• -40 °C to +125 °C
Weight, approx.
1) 2 hours, 2 m, +20 °C
35 g
2) steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C
3) The values for shock and vibration are maximum values and must not be applied continuously.
Note
It is recommended that a test is performed in critical applications.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 233
Transponder
7.20 MDS D428
7.20.5 Dimension drawing
Dimensions in mm
Figure 7-52 Dimension drawing of MDS D428
234
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
7.21 MDS D460
7.21.1
MDS D460
Characteristics
Characteristics
Field of application
Memory
Read/write range
Mounting on metal
High resistance
Standard
Identification in small assembly lines
FRAM 2048 bytes gross
2000°bytes net
See Chapter Field data (Page 35).
With spacer:
Recommended distance from metal ≥ 10 mm
Can also be used in a harsh industrial environment
Oriented according to ISO standard 15693
7.21.2 Ordering data
Table 7- 40 Ordering data of MDS D460
MDS D460
Spacer for MDS D160 / MDS D460
Order number
6GT2600-4AB00
6GT2690-0AG00
Transponder
7.21 MDS D460
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 235
Transponder
7.21 MDS D460
7.21.3 Mounting on metal
Mounting option on metal with spacer
① Transponder
② Metal
③ Spacer h ≥ 10 mm
Figure 7-53 Mounting of the MDS D460 on metal with spacer
Note
If the minimum guide values (h) are not observed, a reduction of the field data results.
In critical applications, it is recommended that a test is performed.
Flush-mounting
Flush-mounting of the MDS D460 in metal is not permitted!
236
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
7.21.4
Transponder
7.21 MDS D460
Technical specifications
Memory size
Memory configuration
• Serial number
• Configuration memory
• Application memory
2048 bytes
• 8 bytes (fixed code)
• 40 bytes
• 2000 bytes
Storage technology
Memory organization
Protocol
Data retention (at +40 °C)
MTBF (at +40 °C)
Bulk detection/multitag capability
Read cycles
Write cycles (at +40 °C, typical)
Read/write distance (S g
)
Distance from metal
Power supply
FRAM
2048 bytes gross
2000 bytes net
Only for the RF300:
When using the OPT area, 16 bytes of it must be subtracted in 8 byte blocks
ISO 15693
10 years
2 x 10 6 hours
Yes
Unlimited
> 10 10
See Chapter Field data (Page 35)
≥ 10 mm (approx. 25% reduction of the field data)
Inductive power transmission
(without battery)
Degree of protection to EN 60529 IP67
IPx9K 1)
Shock, tested in accordance with IEC 68-2-27 50 g 2)
Vibration, tested in accordance with IEC 68-2-6 20 g 2)
Torsion and bending load
Enclosure
Not permissible
• Color
• Material
• Dimensions (D x H) in mm
• Black
• Epoxy casting resin
• 16 (±0.2) x 3.0 (±0.2)
MDS fixing
Ambient temperature
• During operation
• Transport and storage
Adhesion, spacer
•
•
-25 °C to +85 °C permanent
-40 °C to +100 °C
Weight, approx. 3 g
1) steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C
2) The values for shock and vibration are maximum values and must not be applied continuously.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 237
Transponder
7.21 MDS D460
7.21.5 Dimension drawings
Dimensional drawing of MDS D460
Dimensions in mm
Figure 7-54 Dimensional drawing of MDS D460
Dimensional drawing of spacer
Dimensions in mm
Figure 7-55 Dimensional drawing of spacer
238
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Accessories
8
8.1 Antenna splitter
Area of application
Antenna splitter Characteristics
Area of application Designed for distributed mounting of antennas in warehouses, logistics and distribution
RF290R Readers that can be connected
Number of antennas that can be connected
Connectable antennas
Degree of protection max. 4
(by cascading)
• ANT D5
• ANT D6
• ANT D10
IP65
The antenna splitter is a power distributor with electrical isolation between the input (IN) and the two outputs (OUT1, OUT2). At the operating frequency of 13.56 MHz, the impedance at all inputs and outputs is 50 ohms.
The device is used to connect 2 to 4 antennas to a reader. Gate, C and tunnel arrangements are therefore possible (see section "Configuration options").
Ordering data
Table 8- 1 Ordering data for the antenna splitter
Antenna splitter
(incl. one antenna connecting cable 3.3 m)
Order number
6GT2690-0AC00
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 239
Accessories
8.1 Antenna splitter
Table 8- 2 Ordering data - accessories - antenna splitter
Antenna cable
Antenna cable extension
Length 3.3 m
Length 10.5 m
Length 7.2 m
Order number
6GT2691-0CH33
6GT2691-0CN10
6GT2691-0DH72
Technical specifications
Table 8- 3 Technical specifications for antenna splitter
Technical specifications
Max. input power
Transmission frequency
Power supply
Housing dimensions (L x W x H)
Color
Material
Connector (inputs and outputs)
Securing
Ambient temperature
• During operation
• During transportation and storage
10 W
13.56 MHz
None
160 x 80 x 40 mm
(without connector)
Anthracite
Plastic PA 12
TNC connector
2 x M5 screws
•
•
-25 ℃ ... +65 ℃
-25 ℃ ... +75 ℃
MTBF
Degree of protection according to EN 60529
Shock resistant according to EN 60721-3-7
Class 7M2
Total shock response spectrum Type II
3.0 x 10 5 hours
IP65 (UL: for indoor use only)
30 g
Vibration according to EN 60721-3-7 Class 7M2 1 g (9 ... 200 Hz) /
1.5 g (200 ... 500 Hz)
Weight, approx.
Approval
400 g
CE
UL
240
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
8.2
Accessories
8.2 Antenna multiplexer SIMATIC RF260X
Antenna multiplexer SIMATIC RF260X
8.2.1 Characteristics
The SIMATIC RF260X antenna multiplexer can be used to operate up to six antennas on one reader.
SIMATIC RF260X antenna multiplexer
Characteristics
Area of application Designed for distributed mounting of antennas in warehouses, logistics and distribution
RF290R Readers that can be connected
Number of antennas that can be connected
Connectable antennas
Degree of protection maximum of 6
• ANT D5
• ANT D6
• ANT D10
IP65
8.2.2 Ordering data
Table 8- 4 SIMATIC RF260X ordering data
SIMATIC RF260X
Antenna multiplexer incl. antenna connecting cable 0.4 m
Order number
6GT2894-0EA00
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 241
Accessories
8.2 Antenna multiplexer SIMATIC RF260X
Table 8- 5 SIMATIC RF260X accessories ordering data
24 V connecting cable, 5 m
RF290R
Wide-range power supply unit for SIMATIC RF-systems
(100 - 240 V AC / 24 V DC / 3 A) with 2 m connecting cable with country-specific plug
RS-232 connecting cable, with 4-pin M12 connector for 24 V for connection to the wide-range power supply unit, 5 m
ANT D5 incl. antenna connecting cable (3.3 m)
ANT D6 incl. antenna connecting cable (3.3 m)
ANT D10 incl. antenna connecting cable (3.3 m)
Antenna cable 3.3 m
10.5 m
Antenna cable extension 7.2 m
Order number
6GT2491-1HH50
6GT2821-0AC12
EU: 6GT2898-0AA00
UK: 6GT2898-0AA10
US: 6GT2898-0AA20
6GT2891-4KH50
6GT2698-5AA10
6GT2698-5AB00
6GT2698-5AF00
6GT2691-0CH33
6GT2691-0CN10
6GT2691-0DH72
8.2.3 Description
①
24 V DC power supply
②
Antenna connections OUT 1 to OUT 6
Color Status LED
Yellow Lit when the corresponding antenna output is active.
③ SLG antenna connection "IN"
④ LEDs
LED Color Status LED
COMM / ERR Red • Flashes when the RF260X receives a signal from the SLG. (Only with commands, directly on the RF260X)
• Lit when the multiplexer has detected an error on the output
(e.g. non-terminated antenna cable, defective antenna cable)
HF - ON
RUN
Green Lit when an HF signal is applied to the "IN" socket
③
Green Flashes when the RF260X is in the normal operating state.
242
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
8.2.4
8.2.5
Accessories
8.2 Antenna multiplexer SIMATIC RF260X
Principle of operation
You can operate up to six antennas on one reader by using the multiplexer RF260X. The data is processed sequentially.
Antenna switchover is performed in time-multiplex mode, so by connecting several antennas together, the processing time / activation time per antenna is lengthened accordingly.
Connectors
● Power supply
Pin
● Reader connector ③
Pin, casing side
2
3
4
4-pin M12
1
Assignment
RF260X
Ground (0 V)
+ 24 V
+ 24 V
Ground (0 V)
Figure 8-1 Reader connector
If a longer antenna cable is required between the RF290R and SIMATIC RF260X multiplexer, a 7.2 m long cable (e.g. 6GT2691-0DH72) must be used to extend it, see
The excess length must then be rolled up bifilar and fastened to minimize interference from external sources.
● Antenna outputs ② (OUT 1 to OUT 3 / OUT 4 to OUT 6)
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 243
Accessories
8.2 Antenna multiplexer SIMATIC RF260X
8.2.6 Configuration
Figure 8-2 Configuration example with ANT D5
244
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
8.2.7
Accessories
8.2 Antenna multiplexer SIMATIC RF260X
Parameterization
Parameter settings can be performed using the tool "RF290R-Set" (V9.5.2).
This tool is primarily used for parameterization and commissioning, and is not designed for productive operation.
The relevant parameters of the RF260X can be set in the "Configuration" menu under
"SystemParameters > CFG15: Antenna Multiplexing" ①
Figure 8-3 Menu "Configuration" MOBYDSet"
● For operation with RF260X, you need to activate the "Multiplexing" function ② .
● The number of occupied channels must be specified under "Number of Output Channels"
② .
● In "Multiplexer Valid Times" ③ , the maximum time available for the antenna to read a transponder is entered. Following this time, the device switches to the next antenna automatically. If the read was successful, the time may be significantly shorter than specified here.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 245
Accessories
8.2 Antenna multiplexer SIMATIC RF260X
Note
Changing the parameter assignment
• Note that if you change the parameter settings of the reader or the RF260X in scanner mode, this may lead to frame collisions. These collisions result when the frame is sent while a transponder is present.
• The "Transponder response time" (setting: "CFG2: COM interface") during operation of the RF260X must be higher than the total delay time for all the connected antennas
(CFG15: MUX-VALD-TIME × Number of Output Channels ≤ Transponder Response
Time)
8.2.8 RF260X commands
Using the tool "RF290R-Set" (V9.5.2), certain commands can also be sent to the RF260X. In the "Commands" menu under "RF260X", the following commands can be sent:
● Detect (detection of the RF260X by the reader)
● Channel Select (set to a static channel)
● CPU-Reset (restart the RF260X software)
● Software Version (read out software and hardware versions)
246
Figure 8-4 Sending commands from the "RF290R-Set" tool
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
8.2.9
Accessories
8.2 Antenna multiplexer SIMATIC RF260X
Technical specifications
Technical specifications
Max. write/read distance
ANT ↔ Transponder (S g
)
Number of channels
•
•
Input channels
Output channels
Impedance
Power supply
Current consumption
Dimensions (L x W x H)
Length of the connecting cable
Color
Material
Plug-in connections
See manual for the relevant antenna
• 1
• 6
50 ohm
24 V (± 10 %) max. 200 mA
240 x 150 x 70 mm
0.4 m
Anthracite
Aluminum die-casting
• Power supply: Four-pole M12 / 4 pole round connector
• Reader antenna connector: Single-pole TNC socket
• Antenna connections: 6 x TNC socket
Max. power (reader input, or per antenna)
Shock resistant according to EN 60721-3-7
Class 7M2
Total shock response spectrum Type II
8 W
1 g
Vibration according to EN 60721-3-7 Class 7M2 1.5 g (5 to 500 Hz)
Securing 4 M5 screws
Tightening torque
(at room temperature)
≤ 5 Nm
Ambient temperature
• During operation
• During transportation and storage
•
•
-20 ℃ ... +55 ℃
-25 ℃ ... +70 ℃
MTBF
Degree of protection according to EN 60529
Weight, approx.
Approvals
2.5 x 10 6 hours
IP65
1.8 kg
CE / FCC / IC
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 247
Accessories
8.2 Antenna multiplexer SIMATIC RF260X
8.2.10 Dimensional drawing
248
Figure 8-5 RF260X dimension drawing
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
8.3
8.3.1
Accessories
8.3 Wide-range power supply unit for SIMATIC RF systems
Wide-range power supply unit for SIMATIC RF systems
Features
Wide-range power supply unit for SIMATIC RF systems
① DC output 1
②
DC output 2
③
Network connector
Characteristics
• Wide-range input
③
for use worldwide
• Dimensions without mains cable: 175 x 85 x 35 mm
• Dimensions including mains cable: 250 x 85 x 35 mm
• CE-compliant (EU and UK versions)
• UL-certified for US and Canada (US version)
• Mechanically and electrically rugged design
• Secondary side
①
,
②
: 24 VDC / 3 A
• Short-circuit and no-load stability
• Suitable for frame mounting
• 3 versions for use in the EU, UK, US
Description
The wide-range power supply unit for SIMATIC RF systems is a universal compact power supply and provides the user with an efficient, cost-saving solution for many different midrange power supply tasks.
The primary switched power supply is designed for use on single-phase AC systems. The two DC outputs (sockets) are connected in parallel and protected by a built-in current limiting circuit against overload and short-circuits.
The device is vacuum-cast and prepared for Safety Class 2 applications. The EU and UK versions satisfy the low-voltage guideline as well as the current EU standards for CE conformity. Furthermore, the US version has been UL-certified for the US and Canada.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 249
Accessories
8.3 Wide-range power supply unit for SIMATIC RF systems
8.3.2 Scope of supply
● Wide-range power supply unit for SIMATIC RF systems
● 2 m mains cable (country-specific)
● Protective cover for flange outlet
● Operating Instructions
8.3.3 Ordering data
Table 8- 6 Ordering data for wide-range power supply unit
Wide-range power supply unit for SIMATIC RF systems (100 -
240 VAC / 24 VDC / 3 A) with 2 m connecting cable with countryspecific plug
24 V-connecting cable, length 5 m
Order number
EU: 6GT2898-0AA00
UK: 6GT2898-0AA10
US: 6GT2898-0AA20
6GT2491-1HH50
8.3.4 Safety Information
WARNING
Danger to life
It is not permitted to open the device or to modify the device.
The following must also be taken into account:
• Failure to observe this requirement shall constitute a revocation of the CE approval, UL certification for the US and Canada as well as the manufacturer's warranty.
• For installation of the power supply, compliance with the DIN/VDE requirements or the country-specific regulations is essential.
• The field of application of the power supply unit is limited to "Information technology equipment" within the scope of validity of the EN 60950/VDE 0805 standard.
• When the equipment is installed, it must be ensured that the mains socket outlet is freely accessible.
• The housing can reach a temperature of +25 °C during operation without any adverse consequences. It must, however, be ensured that the power supply is covered in the case of a housing temperature of more than +25°C to protect persons from contact with the hot housing. Adequate ventilation of the power supply must be maintained under these conditions.
250
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Accessories
8.3 Wide-range power supply unit for SIMATIC RF systems
NOTICE
Area of application of the wide-range power supply unit
The wide-range power supply unit may only be used for SIMATIC products in the specifically described area of application and for the documented purpose.
If the wide-range power supply unit for SIMATIC RF systems is used for an end product other than one from the SIMATIC RF family, the following must be taken into account:
● The electric strength test of the end product is to be based upon a maximum working voltage of: Transition from primary to SELV: 353 VDC, 620 Vpk
● The following secondary output circuits are SELV (low voltage; SELV = Safety Extra Low
Voltage): all
● The following secondary output circuits are at non-hazardous energy levels: all
● The power supply terminals and/or connectors are suitable for field wiring if terminals are provided.
● The maximum investigated branch circuit rating is: 20 A
● The investigated pollution degree is: 2
WARNING
Liability
If the wide-range power supply unit for SIMATIC RF systems is connected to an end product other than one from the SIMATIC RF family, the end user is responsible and liable for operation of the system or end product that includes the wide-range power supply unit for SIMATIC RF systems.
NOTICE
Restriction to the approval of the wide-range power supply
The SIMATIC RF290R reader may only be operated with power supplies that have received KETI approval. There is currently no KETI approval for the wide-range power supply (6GT2898-0AAx0), which is why it may not be operated in South Korea.
To be able to operate the SIMATIC RF290 reader in South Korea, use only a power unit that meets the following requirements: 230 VAC, 24 VDC / 3 A; KC safety approved
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 251
Accessories
8.3 Wide-range power supply unit for SIMATIC RF systems
8.3.5 Connecting
● There are three different (country-specific) mains cables for the EU, UK and US.
The appropriate mains cable must be connected to the primary input of the power supply.
Note
It is only permissible to insert or remove the mains cable when the power supply is deenergized.
● The wide-range power supply unit has total insulation (Safety Class 2), IP65
● It can be mounted using four fixing holes.
8.3.6 Technical specifications
General technical specifications
Insulation stability (prim./sec.) U ins p/s
Insulation resistance R ins
Leakage current I
Safety class (SELV)
Mains buffering t h leak
3.3 kV
AC
>1 GΩ
U in
= 230 V
AC
, f = 50 Hz < 200 µA
Designed for installation in devices of Safety Class 2
U in
= 230 V
AC
≥ 50 ms
Ambient temperature
Surface temperature
Storage temperature
Self-heating on full-load
Interference immunity
ESD
HF fields
Burst
Surge
HF injection
Mains quality test
Cooling
Dimensions L x W x H
Weight
Housing / casting
Module top, center
EN 61000-4-2,
4-3 to 4-6, 4-11
-25 ℃ ... +55 ℃ max. 96 ℃
-40 ℃ ... +85 ℃ max. 45 K
Air discharge: 15 kV
10 V/m symmetrical: 2 symmetrical: 1
10 V rms
Free convection
175 mm x 85 mm x 35 mm
720 g
UL 94-V0
Power supply class
Degree of protection
MTBF in years according to CSA
IP65
Level 3
255
252
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Accessories
8.3 Wide-range power supply unit for SIMATIC RF systems
Technical specifications - input
Rated input voltage U in
Input frequency f in
Radio interference level
Switching frequency f sw
Length of cable
Technical specifications - output
Output voltage tolerance ∆U out
Overvoltage protection
Noise ∆U
LF
Noise ∆U
HF
Regulation
•
•
Line regulation
Load regulation
Short-circuit current I
Settling time t
R
load variations
Temperature coefficient ε
Overload behavior P over
Short-circuit protection/
No-load response
Derating
Connector type max
EN 60950 / UL 60950
U in
= 230 V
AC
U in
= min., BW: 1 MHz
U in
= min., BW: 20 MHz
• U in
= min./max.
• I out
= 10...90...10 %
I nom
= 4 A (+50 °C)
I out
= 10 ... 90 ... 10 %
T
A
= -25 °C to +70 °C
T
A
> +50 °C to +70 °C
Technical specifications - initial configurations
Input Outputs U1 = U2 ILoad = I1 + I2
110 VAC
110 VAC
24 VDC
24 VDC
0 A
3 A
220 VAC
220 VAC
24 VDC
24 VDC
0 A
3 A
100 to 240 VAC
120 to 353 VDC
50/60 Hz
EN 55011/B approx. 70 kHz typ.
2 m
U out nom
≤ +2 %/-1 %
U out nom
+20 % typ.
≤ 1 % U out
≤ 2 % U out
• ≤ 1,0 %
• ≤ 1,0 %
105 ... 130 % I nom
< 5 ms
0.01 %/K
Constant current
Continuous/no-load stability max. 2 %/K
M12, 4-pin; two sockets
Efficiency (%)
≥ 88
≥ 90
Remarks
No-load stability
No-load stability
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 253
Accessories
8.3 Wide-range power supply unit for SIMATIC RF systems
Technical specifications - standards complied with
Designation
Electrical safety
Conducted interference
Standard Values
EN 60950 / UL 60950 / CAN/CSA 22.2 950, 3 Edition
Class B
Emission
EN 61000-6-3
EN 55011
EN 61000-6-3
EN 55011
Class B
All values are measured at full-load and at an ambient temperature of +25 ℃ (unless specified otherwise).
8.3.7 Pin assignment of DC outputs and mains connection
DC outputs Assignment
(1) Ground (0V)
(2) +24 V DC
(3) +24 V DC
(4) Ground (0V)
Mains connection Assignment
(1) 100 to 240 V AC
(2) n.c.
(3) 100 to 240 V AC
(4) n.c.
254
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
8.3.8 Dimension drawing
Accessories
8.3 Wide-range power supply unit for SIMATIC RF systems
Figure 8-6 Dimension drawing wide-range power supply unit for SIMATIC RF systems (all dimensions in mm)
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 255
Accessories
8.3 Wide-range power supply unit for SIMATIC RF systems
8.3.9 Certificates and approvals
Table 8- 7 Wide-range power supply unit for SIMATIC RF systems 6GT2898-0AA00 - Europe,
6GT2898-0AA10 - UK
Certificate Description
CE approval to
2004/108/EC EMC
73/23/EEC LVD
Table 8- 8 Wide-range power supply unit for SIMATIC RF systems 6GT2898-0AA20 - USA
Standard
This product is UL-certified for the US and Canada.
It meets the following safety standards:
UL 60950-1 - Information Technology Equipment Safety - Part 1:
General Requirements
CSA C22.2 No. 60950 -1 - Safety of Information Technology
Equipment
UL Report E 205089
256
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
System integration
The communication modules (interface modules) are links between the RFID components
(reader and transponder) and the higher-level controllers (e.g. SIMATIC S7), or PCs or computers.
9
Figure 9-1 Configuration example
Interfacing to the controller
The readers are connected to the controller via the following interface or communications modules:
● ASM 456
● ASM 475
● RF120C
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 257
System integration
● RF160C
● RF170C
● RF180C
● RF182C
● RFID 181EIP
Function blocks, interface modules/communication modules and readers
Function blocks are used for integration into the SIMATIC. They are used to transfer the input parameters to the reader using the "init_run"(RESET) command.
Interface modules/communication modules and function blocks
The following table shows the most important features of the interface modules/communication modules, as well as the compatible function blocks.
When assigning parameters (HW Config) to the communications and interface modules,
MOBY U/D/RF200/RF300/RF600 must be selected.
Table 9- 1 Overview of interface modules/communication modules
ASM/ communications module
ASM 456
Interfaces to the application (PLC)
Interfaces to the reader
ASM 475
RF120C
RF160C
RF170C
RF180C
RF182C
RFID 181EIP
Function blocks Reader connections
PROFIBUS DP-V1
S7-300 (central),
ET200M (PROFIBUS)
S7-1200 (central)
PROFIBUS DP-V0
PROFIBUS DP-V1
PROFINET IO
PROFINET IO
TCP/IP
Ethernet/IP
2 x 8-pin connector socket,
M12
Via screw terminals in front connector
9-pin D-sub socket
2 x 8-pin connector socket,
M12
2 x 8-pin connector socket,
M12
2 x 8-pin connector socket,
M12
2 x 8-pin connector socket,
M12
2 x 8-pin connector socket,
M12
FB 45
FB 45
Ident profile
FC 44
FB 45
FB 45
__
__
2 (parallel)
2 (parallel)
1
2 (parallel)
2 (parallel)
2 (parallel)
2 (parallel)
2 (parallel)
You will find more information on the communications modules in the relevant manuals
( http://support.automation.siemens.com/WW/view/en/10805849 ). For more detailed information on the ASM 475, refer to the RF300 system manual.
258
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
System diagnostics
10
10.1 Error codes of the RF200 readers
Note
Validity of the error codes
The following error codes apply only to RF200 readers with an S-422 interface (CM mode)
You can determine the error code in two ways:
● directly on the reader/CM by counting the flashing pattern of the red error LED
● Through the FB45 variable "error_MOBY".
Table 10- 1 Error codes of the RF200 readers
Flashing of red LED on reader
00
02
05
06
12
13
19
20
21
24
25
28
Error code
(hexa- decimal)
00
01
05
06
0C
0D
13
14
15
18
19
1C
Description no error
Presence error, possible causes:
• The active command was not carried out completely
• The transponder left the antenna field while the command was being processed - communication disruption between reader and transponder
Parameterization error, possible causes:
• Unknown command
• Incorrect parameter
• Function not allowed
Air interface faulty
The transponder memory cannot be written, possible cause:
Hardware fault (memory faulty)
Error in the specified memory address (access attempted to nonexistent or non-accessible memory areas).
Buffer overflow: Insufficient buffer available in the reader for saving the command
Major system fault (hardware fault)
Parameter assignment error: faulty parameter in RESET command
Only a RESET command is permitted
Previous command is still active
Antenna is already switched off/Antenna is already switched on
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 259
System diagnostics
10.2 Diagnostic functions
Flashing of red LED on reader
30
-
Error code
(hexa- decimal)
1E
1F
Description
Incorrect number of characters in frame
Running command cancelled by "RESET" command
Note
Error message when memory area is protected
For transponders with a locked or protected memory area, different error messages can occur following a write command depending on the data carrier type, e.g. MDS D1xx (NXP),
D3xx (Infineon), D4xx (Fujitsu): Error 01, 0C
10.2 Diagnostic functions
Further information on RFID diagnostic options can be found in Function Manual FB 45
( http://support.automation.siemens.com/WW/view/en/21738808 ).
10.2.1 Reader diagnostics with SLG STATUS
The SLG STATUS command can be used to scan the status and diagnostics data of the reader.
SLG STATUS (mode 01), corresponds to UDT 110
Name hardware hardware_version loader_version firmware
Type char word word char
Possible values Comment
(31 to 38 hex)
31 hex
32 hex
33 hex
34 hex
3A hex
Type of hardware
= RF260R
= RF210/220R
= RF240R
= RF250R
= RF290R
0 to FF hex
0 to FF hex
0 to FF hex
0 to FF hex
0 to FF hex
HW version (reserved)
= Version (high byte)
= Version (low byte)
Bootstrap loader version: e.g. 3130 (=version
1.0)
= Version (high byte)
= Version (low byte)
FW version : 33 (ASCII : 3 = RF2x0R)
260
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
System diagnostics
10.2 Diagnostic functions
Name firmware_version driver driver_version interface baud multitag_SLG
Type word char word byte byte byte field_ON_time_SLG byte status_ant
MDS_control byte byte
01 hex
01 hex
02 hex
00 hex
01 hex
0 to FF hex
0 to FF hex
31 hex
0 to FF hex
0 to FF hex
01 hex
02 hex
01 hex
03 hex
05 hex
01 hex
Possible values Comment
Firmware version: e.g. 3130 (=version 1.0)
= Version (high byte)
= Version (low byte)
Type of driver
3964R
Driver version: e.g. 3132 (=version 1.2)
= Version (high byte)
= Version (low byte)
Interface type
= RS-422
= RS-232
Baud rate
= 19.2 kBd
= 57.6 kBd
= 115.2 kBd
Number of transponders (multitag/bulk) that can be processed in the antenna field
= Single tag mode
ISO transponder (non-specific)
Status of antenna
= Antenna is on
= antenna is off
Presence status
= Operation without presence message
= Operation with presence message
Note
Unassigned fields in the UDT are not listed here.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 261
System diagnostics
10.2 Diagnostic functions
10.2.2 Transponder diagnostics with MDS STATUS
The MDS STATUS command can be used to scan the status data of the transponder that is located within the antenna field.
MDS STATUS for ISO transponder (mode 03) corresponds to UDT 230
Table 10- 2 MDS STATUS for ISO mode
Name
UID
Type array[1…8] byte
MDS_type
IC_version size byte byte word
Possible values
000000000
0000000 hex to
FFFFFFFF
FFFFFFFF hex
01 hex
03 hex
04 hex
05 hex
06 hex
07 hex
0 to FF hex
0 to FF hex lock_state block_size byte byte
0 to FF hex
0 to FF hex nr_of_blocks byte 0 to FF hex
Comment
Unique identifier
=8 byte UID, MSB first
Tag type (chip manufacturer, designation)
= ISO general (non-specific or unknown)
= my-d (Infineon), MDS D3xx
= MB89R118 (Fujitsu), MDS D4xx
= I-Code SLI (NXP), MDS D1xx
= Tag-it HFI (Texas Instruments), MDS D2xx
= LRI2K (ST)
Chip version
Memory size in bytes
Depending on tag type, e.g. my-d: 992 bytes
–not used with RF200
Block size of the transponder
Depending on tag type, e.g. my-d: 4 bytes
Number of blocks
Depending on tag type, e.g. my-d: 248
262
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Appendix
A
A.1 Certificates and approvals
Certificate Description
Conformity with R&TTE directive
Notes on CE marking
The following applies to the system described in this documentation:
The CE marking on a device indicates the corresponding approval:
DIN ISO 9001 certificate
The quality assurance system for the entire product process (development, production, and marketing) at Siemens fulfills the requirements of ISO 9001 (corresponds to EN29001:
1987).
This has been certified by DQS (the German society for the certification of quality management systems).
EQ-Net certificate no.: 1323-01
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 263
Appendix
A.1 Certificates and approvals
Certifications for the United States, Canada, and Australia
Safety
One of the following markings on a device is indicative of the corresponding approval:
Underwriters Laboratories (UL) per UL 60950 (I.T.E) or per UL 508 (IND.CONT.EQ)
Underwriters Laboratories (UL) according to Canadian standard C22.2 No. 60950
(I.T.E) or C22.2 No. 142 (IND.CONT.EQ)
Underwriters Laboratories (UL) according to standard UL 60950, Report E11 5352 and
Canadian standard C22.2 No. 60950 (I.T.E) or UL508 and C22.2 No. 142
(IND.CONT.EQ)
UL recognition mark
Canadian Standard Association (CSA) per Standard C22.2. No. 60950 (LR 81690) or per C22.2 No. 142 (LR 63533)
Canadian Standard Association (CSA) per American Standard UL 60950 (LR 81690) or per UL 508 (LR 63533)
EMC
USA
Federal Communications
Commission
Radio Frequency
Interference Statement
Shielded Cables
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Shielded cables must be used with this equipment to maintain compliance with FCC regulations.
Modifications Changes or modifications not expressly approved by the manufacturer could void the user's authority to operate the equipment.
Conditions of Operations This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
CANADA
Canadian Notice This Class A digital apparatus complies with Canadian ICES-003.
264
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
A.2
A.2.1
Appendix
A.2 Connecting cable
AUSTRALIA
This product meets the requirements of the AS/NZS 3548 Norm.
Connecting cable
RF2xxR reader (RS-422) with ASM 456 / RF160C / RF170C / RF180C
Connecting cable with straight connector
Figure A-1 Connecting cable between ASM 456, RF160C, RF170C, RF180C and RF2xxR reader
(RS-422)
Table A- 1 Ordering data
Length L
2 m
5 m
10 m
20 m
50 m
Order number
6GT2891-4FH20
6GT2891-4FH50
6GT2891-4FN10
6GT2891-4FN20
6GT2891-4FN50
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 265
Appendix
A.2 Connecting cable
Connecting cable with angled connector
Figure A-2 Connecting cable between ASM 456, RF160C, RF170C, RF180C and RF2xxR reader
(RS-422) with angled connector
The angled connector has a height of h = 29 mm and a length of l = 38 mm. Remember that due to the construction, the distance between the edge of the connector and the edge of the reader housing is higher.
The distance between the edge of the connector and the edge of the housing is as follows:
RF210R/RF220R = 33 mm, RF240R/RF260R = 36 mm and RF290R = 37 mm.
Table A- 2 Ordering data
Length L
2 m
Order number
6GT2891-4JH20
266
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Appendix
A.2 Connecting cable
A.2.2 Reader RF2xxR (RS-422) with ASM 475
Reader connection system
The connecting cable has a length of 2 m (standard) and 5 m. Extensions up to 1000 m are possible with the 6GT2891-4F… plug-in cables.
Figure A-3 Connecting cable between the ASM 475 and RF2xx reader (RS-422)
Table A- 3 Ordering data
Length L
2 m
5 m
Order number
6GT2891-4EH20
6GT2891-4EH50
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 267
Appendix
A.2 Connecting cable
A.2.3 Reader RF240R/RF260R/RF290R (RS232) with PC
With 4-pin power supply connector
The connecting cable (6GT2891-4KH50) is 5 m long.
Special feature of the cable: additional branch for the power supply.
Figure A-4 Connecting cable between PC and RF240R/RF260R/RF290R (RS-232) with 4-pin power supply connector
Suitable power supply unit: e.g. wide-range power supply unit
With open ends for the power supply
Figure A-5 Connecting cable between PC and RF240R/RF260R/RF290R (RS-232) with open ends for the power supply
Table A- 4 Ordering data connecting cable
Connecting cable RS-232 with M12 male connector (4-pin), 5 m
Connecting cable RS-232 with open ends (5 m)
Order number
6GT2891-4KH50
6GT2891-4KH50-0AX0
268
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Appendix
A.3 Ordering data
A.3 Ordering data
RF200 components
Table A- 5 RF200 reader
Readers
RF210R
RF220R
RF240R
RF240R
RF240R
RF250R
Description
• With RS422 interface (3964R)
• IP67
• Operating temperature: -25 ℃ ... +70 ℃
• Dimensions (L x Ø): 83 x 18 mm
• with integrated antenna
• With RS422 interface (3964R)
• IP67
• Operating temperature: -25 ℃ ... +70 ℃
• Dimensions (L x Ø): 83 x 30 mm
• with integrated antenna
• With RS422 interface (3964R)
• IP67
• Operating temperature: -20 ℃ ... +70 ℃
• Dimensions (L x W x H): 50 x 50 x 30 mm
• with integrated antenna
• With RS-232 interface (3964R)
• IP67
• Operating temperature: -20 °C ... +70 °C
• Dimensions (L x W x H): 50 x 50 x 30 mm
• with integrated antenna
• With RS-232 interface (ASCII)
• IP67
• Operating temperature: -20 °C ... +70 °C
• Dimensions (L x W x H): 50 x 50 x 30 mm
• with integrated antenna
• With RS422 interface (3964R)
• IP67
• Operating temperature: -20 °C ... +70 °C
• Dimensions (L x W x H): 50 x 50 x 30 mm
• Reader with connections for external antennas ANT 8, ANT 12, ANT
18, ANT 30
Article number
6GT2821-1AC10
6GT2821-2AC10
6GT2821-4AC10
6GT2821-4AC11
6GT2821-4AC40
6GT2821-5AC10
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 269
Appendix
A.3 Ordering data
Readers
RF250R
RF260R
RF260R
RF260R
RF290R
RF310M
RF310M
Description
• With RS-232 interface (ASCII)
• IP67
• Operating temperature: -20 °C ... +70 °C
• Dimensions (L x W x H): 50 x 50 x 30 mm
• Reader with connections for external antennas ANT 8, ANT 12, ANT
18, ANT 30
• With RS422 interface (3964R)
• IP67
• Operating temperature: -20 ℃ ... +70 ℃
• Dimensions (L x W x H): 75 x 75 x 41 mm
• with integrated antenna
• With RS-232 interface (3964R)
• IP67
• Operating temperature: -20 °C ... +70 °C
• Dimensions (L x W x H): 75 x 75 x 41 mm
• with integrated antenna
• With RS-232 interface (ASCII)
• IP67
• Operating temperature: -20 °C ... +70 °C
• Dimensions (L x W x H): 75 x 75 x 41 mm
• with integrated antenna
• With RS-232 interface and
RS-422 interface (3964R)
• IP65
• Operating temperature: -20 °C ... +55 °C
• Dimensions (L x W x H): 200 x 140 x 80 mm
• Long-range reader with the option of connecting external antennas
ANT D5, ANT D6, ANT D10
• IP65
• Operating temperature: -20 °C ... +50 °C
• Dimensions (L x W x H): 277 x 100 x 44 mm
• Mobile reader with integrated antenna
• IP65
• Operating temperature: -20 °C ... +50 °C
• Dimensions (L x W x H): 277 x 100 x 44 mm
• Mobile reader with connections for external antennas ANT 8, ANT 12,
ANT 18, ANT 30
Article number
6GT2821-5AC40
6GT2821-6AC10
6GT2821-6AC11
6GT2821-6AC40
6GT2821-0AC12
6GT2803-1AC00
6GT2803-1AC10
270
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Appendix
A.3 Ordering data
Table A- 6 ISO transponder
ISO transponder Description
MDS D100 • IP68
• Memory size: 112 bytes of EEPROM user memory
• Operating temperature range: -25 °C ... +80 °C
• Dimensions (L x W x H): 85.6 (±0.2) x 54 (±0.2) x 0.9 (±0.05) mm
• ISO card
MDS D117 • IP68
• Memory size: Memory size: 112 bytes of EEPROM user memory
• Operating temperature range: -25 °C ... +85 °C
• Dimensions (Ø x H): 4 x 5 mm
MDS D124 • IP67
• Memory size: 112 bytes of EEPROM user memory
• Operating temperature range: -25 °C ... +125 °C
• Dimensions (Ø x H): 27 (±0.2) x 4 (±0.2) mm
MDS D126 • IP68
• Memory size: 112 bytes of EEPROM user memory
• Operating temperature range: -25 °C ... +85 °C
• Dimensions (Ø x H): 50 x 3.6 mm
• Round design with mounting hole
MDS D127 • IP68
• Memory size: 112 bytes of EEPROM user memory
• Operating temperature range: -25 °C ... +125 °C
• Dimensions (Ø x H): M6 x 5 (±0.2) mm
MDS D139 • IP68
• Memory size: 112 bytes of EEPROM user memory
• Operating temperature range: up to +200 °C/+220 °C [heat-resistant
(r/w)]
• Dimensions (Ø x H): 85 (±0.5) x 15 (-1.0) mm
MDS D160 • IP68 (24 hours, 2 m, +20 °C)
• Memory size: 112 bytes of EEPROM user memory
• Operating temperature: -25 ℃ ... +70 ℃
• Dimensions (Ø x H): 16 (±0.2) x 3.0 (±0.2) mm
• Laundry tag for cyclical applications (r/w)
MDS D165 • IP65
• Memory size: 112 bytes of EEPROM user memory
• Operating temperature range: -25 °C ... +85 °C
• Dimensions (L x W): 86 x 54 mm
• Smartlabel (PET) in credit card format
Article number
6GT2600-0AD10
6GT2600-0AG00
6GT2600-0AC10
6GT2600-0AE00
6GT2600-0AF00
6GT2600-0AA10
6GT2600-0AB10
6GT2600-1AB00-0AX0
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 271
Appendix
A.3 Ordering data
ISO transponder Description
MDS D200 • IP67
• Memory size: 256 bytes of EEPROM
• Operating temperature range: -20 °C ... +60 °C
• Dimensions (L x W x H): 86 x 54 x 0.8 mm
• Credit card format
MDS D261 • IP65
• Memory size: 256 bytes of EEPROM user memory
• Operating temperature range: -25 °C ... +85 °C
• Dimensions (L x W): 55 x 55 mm
• Smartlabel (PET), small design
MDS D324 • IP67
• Memory size: 992 bytes of EEPROM user memory
• Operating temperature range: -25 °C ... +125 °C
• Dimensions (Ø x H): 27 (±0.2) x 4 (±0.2) mm
MDS D339
• IP68
• Memory size: 992 bytes of EEPROM user memory
• Operating temperature range: -25 °C ... +220 °C
• Dimensions (Ø x H): 85 (±0.5) x 15 (-1.0) mm
MDS D400 • IP67
• Memory size: 2000 bytes of FRAM user memory
• Operating temperature range: -25 ℃ ...+60 ℃
• Dimensions (L x W x H) 85.6 (±0.3) × 54 (±0.2) × 0.8 (±0.05) mm
MDS D421 • IP67/x9K
• Memory size: 2000 bytes of FRAM user memory
• Operating temperature range: -25 ℃ ... +85 ℃
• Dimensions (Ø x H): 10 x 4.5 mm
MDS D422 • IP68
• Memory size: 2000 bytes of FRAM user memory
• Operating temperature range: -25 ℃ ... +85 ℃
• Dimensions (Ø x H): M20 x 6 (±0.2) mm
• Can be screwed into metal (flush-mounted)
MDS D423 • IP68
• Memory size: 2000 bytes of FRAM user memory
• Operating temperature range: -25 ℃ ... +85 ℃
• Dimensions (Ø x H): 30 (+0.2/-0.5) x 8 (-0.5) mm
Article number
6GT2600-1AD00-0AX0
6GT2600-1AA01-0AX0
6GT2600-3AC00
6GT2600-3AA10
6GT2600-4AD00
6GT2600-4AE00
6GT2600-4AF00
6GT2600-4AA00
272
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Appendix
A.3 Ordering data
ISO transponder Description
MDS D424 • IP67
• Memory size: 2000 bytes of FRAM user memory
• Operating temperature range: -25 °C ... +125 °C
• Dimensions (Ø x H): 27 (±0.2) x 4 (±0.2) mm
MDS D425 • IP68; IP x9K
• Memory size: 2000 bytes of FRAM user memory
• Operating temperature range: -25 °C ... +85 °C
• Dimensions (Ø x H): 24 X 10 mm; M6 thread
• Screw transponder
MDS D426 • IP68
• Memory size: 2000 bytes of FRAM user memory
• Operating temperature range: -25 °C ... +85 °C
• Dimensions (Ø x H): 50 x 3.6 mm
• Round design with mounting hole
MDS D428
• IP68; IP x9K
• Memory size: 2000 bytes of FRAM user memory
• Operating temperature range: -25 °C ... +85 °C
• Dimensions (Ø x H): 18(±1) x 20(±1) mm (without thread); thread M8
MDS D460 • IP68
• Memory size: 2000 bytes of FRAM user memory
• Operating temperature range: -25 °C ... +85 °C
• Dimensions (Ø x H): 16 (±0.2) x 3.0 (±0.2) mm
Article number
6GT2600-4AC00
6GT2600-4AG00
6GT2600-4AH00
6GT2600-4AK00
6GT2600-4AB00
Table A- 7 Communication modules/interface modules
ASM/ communications module
ASM 456
Description
ASM 475
RF120C
RF160C
RF170C
ASM 456 for PROFIBUS DP V1 max. 2 readers can be connected
ASM 475 for SIMATIC S7 max. 2 x RF2xxR readers with RS-422 can be connected at the same time without front connector
Communications module RF120C for SIMATIC S7-1200
Communications module RF160C for PROFIBUS DP V0 max. 2 readers can be connected
RF170C communications module
RF170C connecting block
Article number
6GT2002-0ED00
6GT2002-0GA10
6GT2002-0LA00
6GT2002-0EF00
6GT2002-0HD00
6GT2002-1HD00
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 273
Appendix
A.3 Ordering data
ASM/ communications module
RF180C
RF182C
RFID 181EIP
Description
RF180C communications module max. 2 SLGs or readers can be connected
Connecting block M12, 7/8'' (5-pin)
Connecting block M12, 7/8'' (4-pin)
Push-pull connecting block, RJ-45
RF182C communication module
Max. 2 SLGs or readers can be connected
Connecting block M12, 7/8'' (5-pin)
Connecting block M12, 7/8'' (4-pin)
Push-pull connecting block, RJ-45
RF182C communications module max. 2 SLGs or readers can be connected
Connecting block M12, 7/8'' (5-pin)
Connecting block M12, 7/8'' (4-pin)
Push-pull connecting block, RJ-45
Table A- 8 Antennas
Antennas
ANT 8
ANT 12
ANT 18
ANT 30
Description
• IP67
• Operating temperature: -25 °C ... +70 °C
• Dimensions (Ø x L): M8 x 40 mm
• incl. one antenna connecting cable 3 m
• without antenna connecting cable
• IP67
• Operating temperature: -25 °C ... +70 °C
• Dimensions (Ø x L): M12 x 40 mm
• incl. one antenna connecting cable 3 m
• IP67 (front)
• Operating temperature: -25 °C ... +70 °C
• Dimensions (Ø x L): M18 x 55 mm
• incl. one antenna connecting cable 3 m
• IP67
• Operating temperature: -25 °C ... +70 °C
• Dimensions (Ø x L): M30 x 58 mm
• incl. one antenna connecting cable 3 m
274
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Article number
6GT2398-1CF10
6GT2398-1CF00
6GT2398-1CC00
6GT2398-1CA00
6GT2398-1CD00
Article number
6GT2002-0JD00
6GT2002-1JD00
6GT2002-4JD00
6GT2002-2JD00
6GT2002-0JD10
6GT2002-1JD00
6GT2002-4JD00
6GT2002-2JD00
6GT2002-0JD20
6GT2002-1JD00
6GT2002-4JD00
6GT2002-2JD00
Appendix
A.3 Ordering data
Antennas
ANT D5
ANT D6
ANT D10
Description
• IP65
• Operating temperature: -20 °C ... +55 °C
• Dimensions (L x W x H): 380 x 380 x 110 mm
• incl. one antenna connecting cable 3.3 m
• IP65
• Operating temperature: -20 °C ... +55 °C
• Dimensions (L x W x H): 580 x 480 x 110 mm
• incl. one antenna connecting cable 3.3 m
• IP65
• Operating temperature: -20 °C ... +55 °C
• Dimensions (L x W x H): 1150 x 365 x 115 mm
• incl. one antenna connecting cable 3.3 m
Accessories
Table A- 9 Reader accessories
Readers
RF290R
Accessories
Adapter for mounting on a DIN rail
(pack of 3)
Table A- 10 ISO transponder accessories
Transponder
MDS D100 / D200 /
D400
MDS D139 / D339
Accessories
Spacer
Fixing pocket
Securing pocket
(cannot be mounted directly on metal)
Spacer (Ø x H): 85 x 30 mm
Quick change holder (Ø x H): 22 x 48 mm
Spacer (Ø x H): 35 x 15 mm MDS D124 / D324 /
D424
MDS D126 / D426
MDS D160 / D460
Spacer (Ø x H): 60 x 30 mm
Spacer (Ø x H): 20 x 15 mm
Article number
6GK5798-8ML00-0AB3
Article number
6GT2190-0AA00
6GT2190-0AB00
6GT2390-0AA00
6GT2690-0AA00
6GT2690-0AH00
6GT2690-0AK00
6GT2690-0AL00
6GT2690-0AG00
Article number
6GT2698-5AA10
6GT2698-5AB00
6GT2698-5AF00
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 275
Appendix
A.3 Ordering data
Table A- 11 Antenna accessories
Antennas
ANT 8
ANT D5 / ANT D6 /
ANT D10
ANT D6
Accessories
Antenna connecting cable with M8 plug (with angled plug)
Antenna splitter
(incl. one antenna connecting cable 3.3 m)
Antenna multiplexer SIMATIC RF260X
(incl. one antenna connecting cable 0.4 m)
Antenna cable 3.3 m
Antenna cable extension
Cover
10.5 m
7.2 m
Table A- 12 Accessories - connecting cable RF200 reader ↔ PC
Connecting cable
RF240R / RF260R /
RF290R (RS-232) and PC
Accessories
Connecting cable RS-232 with M12 male connector (4-pin), 5 m
Connecting cable RS-232 with open ends, 5 m
Article number
6GT2391-0AH30
6GT2690-0AC00
6GT2894-0EA00
6GT2691-0CH33
6GT2691-0CN10
6GT2691-0DH72
6GT2690-0AD00
Article number
6GT2891-4KH50
6GT2891-4KH50-0AX0
Table A- 13 Accessories - connecting cable communications module/ASM ↔ reader
Connecting cables
ASM 456 / RF160C /
RF170C / RF180C and RF2xxR reader
(RS-422)
Description
Length
2 m
5 m
10 m
20 m
50 m
2 m
Article number
6GT2891-4FH20
6GT2891-4FH50
6GT2891-4FN10
6GT2891-4FN20
6GT2891-4FN50
6GT2891-4JH20 ASM 456 / RF160C /
RF170C / RF180C and RF2xxR reader
(RS-422) with angled connector
ASM 475 and RF2xxR reader
(RS-422)
2 m
5 m
6GT2891-4EH20
6GT2891-4EH50
276
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Table A- 14 RFID accessories, general
RFID general
DVD "RFID Systems Software & Documentation"
Wide-range power supply unit for SIMATIC RF-systems
(100 - 240 VAC / 24 VDC / 3 A) with 2 m connecting cable with country-specific plug
24 V connecting cable, 5 m
Article number
6GT2080-2AA20
EU: 6GT2898-0AA00
UK: 6GT2898-0AA10
US: 6GT2898-0AA20
6GT2491-1HH50
Appendix
A.3 Ordering data
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 277
Appendix
A.4 Service & Support
A.4 Service & Support
Technical Support
You can access technical support for all IA/DT projects via the following:
● Phone: + 49 (0) 911 895 7222
● Fax: + 49 (0) 911 895 7223
● E-mail ( mailto:[email protected]
)
● Internet: Web form for Support Request ( http://www.siemens.com/automation/supportrequest )
Contacts
If you have any further questions on the use of our products, please contact one of our representatives at your local Siemens office.
The addresses are found on the following pages:
● On the Internet ( http://www.siemens.com/automation/partner )
● In Catalog CA 01
● In the catalog ID 10 specially for Industrial Identification Systems
Service & support for industrial automation and drive technologies
You can find various services on the Support home page
( http://www.siemens.com/automation/service&support ) of IA/DT on the Internet.
There you will find the following information, for example:
● Our newsletter containing up-to-date information on your products.
● Relevant documentation for your application, which you can access via the search function in "Product Support".
● A forum for global information exchange by users and specialists.
● Your local contact for IA/DT on site.
● Information about on-site service, repairs, and spare parts. Much more can be found under "Our service offer".
SIMATIC documentation on the Internet
A guide to the technical documentation for the various SIMATIC products and systems is available on the Internet:
SIMATIC Guide manuals ( http://www.siemens.com/simatic-tech-doku-portal )
278
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Appendix
A.4 Service & Support
RFID homepage
For general information about our identification systems, visit RFID homepage
( http://www.siemens.com/ident/rfid ).
Online catalog and ordering system
The online catalog and the online ordering system can also be found on the Industry Mall
Homepage ( http://www.siemens.com/industrymall/en ).
Training center
We offer appropriate courses to get you started. Please contact your local training center or the central training center in
D-90327 Nuremberg.
Phone: +49 (0) 180 523 56 11
(€ 0.14 /min. from the German landline network, deviating mobile communications prices are possible)
For information about courses, see the SITRAIN homepage ( http://www.sitrain.com
).
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 279
Appendix
A.4 Service & Support
280
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Glossary
Automation system (AS)
A programmable logical controller (PLC) of the SIMATIC S7 system, comprising a central controller, a CPU and various I/O modules.
Battery-free data storage unit
Mobile data storage units which operate without batteries. Power is supplied to the data storage unit across an electromagnetic alternating field.
Byte
A group of eight bits forms a byte
CE marking
Communauté Européenne (product mark of the European Union)
Communication modules
Communication modules ensure the integration of the MOBY and SIMATIC RF identification systems into SIMATIC, SINUMERIK, SIMOTION, PROFIBUS, PROFINET and TCP/IP.
Once supplied with the corresponding parameters and data, they handle data communication. They then make the corresponding results and data available.
Corresponding software blocks (FBs/FCs for SIMATIC) guarantee simple and quick integration into the application.
Data transmission rate
Unit of measurement for the volume of data transmitted within a unit of time, e.g. bytes/s
Detection area
Area with minimum field strength containing the transmission window, as well as the areas in which the field strength is no longer sufficient for data exchange.
Dwell time
The dwell time is the time in which the transponder dwells within the transmission window of a read/write device. The read/write device can exchange data with the transponder during this time.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 281
Glossary
Dynamic mode
In dynamic mode, the data carrier moves past the read/write device at a traversing rate which depends on the configuration. Various checking mechanisms (listen-in check, CRC,
ECC, etc.) ensure error-free data transfer even under extreme environmental conditions. A serial connection (up to 1000 m) is used to connect the read/write device directly to an interface module, PC, or any other system.
Electromagnetic compatibility
Electromagnetic compatibility is the ability of an electrical or electronic device to operate satisfactorily in an electromagnetic environment without affecting or interfering with the environment over and above certain limits.
EMC Directive
Guidelines for electromagnetic compatibility This guideline relates to any electrical or electronic equipment, plant or system containing electric or electronic components.
Equipotential bonding
Potential differences between different parts of a plant can arise due to the different design of the plant components and different voltage levels. It is necessary to compensate for these differences by equipotential bonding: this is done by combining the equipotential bonding conductors of power components and non-power components on a centralized equalizing conductor.
ESD Directive
Directive for handling ESDs.
Frequency hopping
Frequency hopping technique Automatic search for free channels.
In frequency hopping, data packets are transferred between the communication partners on constantly changing carrier frequencies. This makes it possible to react to interference from devices transmitting signals in the same frequency range. If an attempt to send a data packet is unsuccessful, the packet can be transmitted again on a different carrier frequency.
Interface modules (ASM)
See communication modules
Limit distance
The limit distance (S g
) is the maximum clear distance between the upper surface of the read/write device and the transponder at which transmission still functions under normal conditions.
282
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
L
x
Glossary
Length of a transmission window in the x direction
L
y
Length of a transmission window in the y direction
M
Centerpoint of a field of a transmission window
Metal-free area
Distance/area which must be maintained between the transponder and metal in order to prevent interference during data transfer between the transponder and read/write device.
Mobile data storage units (MDS)
See transponder
Multi-tag capability
Multi-tag capability means the ability to use several read/write devices which communicate simultaneously with different data carriers.
Programmable logic controller (PLC)
The programmable logic controllers (PLC) of the SIMATIC S5 system consist of a central controller, one or more CPUs, and various other modules (e.g. I/O modules).
Read/write devices (SLG)
See readers
Read/write distance
See transmission distance
Readers
Readers ensure fast, secure data transfer between mobile data storage units and higherlevel systems (PLCs, PCs, etc.). The data, energy included, are transmitted inductively across an electromagnetic alternating field or by radio. This principle enables contact-free data transmission, ensures high industrial compatibility and works reliably in the presence of contamination or through non-metallic materials.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 283
Glossary
RFID systems
SIMATIC RF identification systems control and optimize material flow and production sequences. They identify reliably, quickly and economically, use non-contact data communication technology, and store data directly on the product. They are also resistant to contamination.
S
a
Operating distance between transponder and reader
Secondary fields
The strength of the secondary fields, which exist in addition to the transmission window, is usually lower than that of the transmission window and depends on the metallic environment.
Secondary fields should not be used in configuring.
S
g
See limit distance
Static mode
In static mode the transponder is positioned at a fixed distance (maximum: limit distance) exactly above the read/write device.
Tag
See transponder
Telegram cycles
The transfer of a read or write command takes place in three cycles, known as message frame cycles. 1 or 2 bytes of user data can be transferred with each command. The acknowledgement transfer (status or read data) takes place in 3 further cycles.
Transmission distance
Distance between communication module (read/write device) and transponder (mobile data storage unit)
Transmission window
Area in which reliable data exchange between transponder and read/write device is possible due to a particular minimum field strength.
284
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Transponder
Glossary
An invented word from transmitter and responder. Transponders are used on the product, the product carrier, the object, or its transport or packaging unit, and contain production and manufacturing data, i.e. all application-specific data. They follow the product through assembly lines, transfer and production lines and are used to control material flow.
Because of their wireless design, transponders can be used, if necessary, at individual work locations or manufacturing stations, where their data can be read and updated.
Transponders consist predominantly of logic, FRAM and/or EEPROM.
If a transponder moves into the transmission window of the reader, the necessary power for all of the circuit components is generated and monitored by the power supply unit. The pulse-coded information is prepared in such a way that it can be processed further as pure digital signals. The handling of data, including check routines, is performed by the logic, which also manages the various memories.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618 285
Glossary
286
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Index
A
Accessories
SIMATIC RF260X antenna multiplexer, 241
Wide-range power supply unit, 249
ANT 12
ANT 18
ANT 30
ANT 8
ANT D10
ANT D5
ANT D6
Antenna
Application Planning
ASM 475
Assignment for connecting cable, 267
C
Communication time
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
D
Diagnostic functions
Direction of motion
Display elements
Dwell time
Dwell time of the transponder, 29
E
F
Field data
Flush-mounting
of transponders and readers, 44
I
Installation
Several readers,
M
Metal
287
Index
Influence on the transmission window, 46
metal-free space
Minimum distance
Transponder to transponder, 40
MOBY antenna splitter
O
Antenna multiplexer SIMATIC RF260X, 241
Interface modules/communication Modules, 273
Wide-range power supply unit, 250
R
Reader RF290R
Readers
Reducing interference due to metal, 43
RF210R reader
RF220R reader
RF240R reader
RF250R reader
RF260R reader
S
Selection criteria
288
SIMATIC RF260X antenna multiplexer, 241
Dwell time of the transponder, 29
System diagnostics
T
Technical documentation
Tracking
Transmission window
Transponder
U
User data
W
Wide-range power supply unit, 249
Pin assignment for DC outputs, 254
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618