HydroSense II (HS2)
Support Software User Guide
Revision: 10/12
C o p y r i g h t © 2 0 1 1 - 2 0 1 2
C a m p b e l l S c i e n t i f i c , I n c .
License for Use
This software is protected by United States copyright law and international
copyright treaty provisions. The installation and use of this software constitutes
an agreement to abide by the provisions of this license agreement.
Campbell Scientific grants you a non-exclusive license to use this software in
accordance with the following:
(1) The purchase of this software allows you to install and use the software on
one computer only.
(2) This software cannot be loaded on a network server for the purposes of
distribution or for access to the software by multiple operators. If the
software can be used from any computer other than the computer on which
it is installed, you must license a copy of the software for each additional
computer from which the software may be accessed.
(3) If this copy of the software is an upgrade from a previous version, you
must possess a valid license for the earlier version of software. You may
continue to use the earlier copy of software only if the upgrade copy and
earlier version are installed and used on the same computer. The earlier
version of software may not be installed and used on a separate computer
or transferred to another party.
(4) This software package is licensed as a single product. Its component parts
may not be separated for use on more than one computer.
(5) You may make one (1) backup copy of this software onto media similar to
the original distribution, to protect your investment in the software in case
of damage or loss. This backup copy can be used only to replace an
unusable copy of the original installation media.
This software may not be sold, included or redistributed in any other software,
or altered in any way without prior written permission from Campbell
Scientific. All copyright notices and labeling must be left intact.
Limited Warranty
The following warranties are in effect for ninety (90) days from the date of
shipment of the original purchase. These warranties are not extended by the
installation of upgrades or patches offered free of charge.
Campbell Scientific warrants that the installation media on which the software
is recorded and the documentation provided with it are free from physical
defects in materials and workmanship under normal use. The warranty does not
cover any installation media that has been damaged, lost, or abused. You are
urged to make a backup copy (as set forth above) to protect your investment.
Damaged or lost media is the sole responsibility of the licensee and will not be
replaced by Campbell Scientific.
Campbell Scientific warrants that the software itself will perform substantially
in accordance with the specifications set forth in the instruction manual when
properly installed and used in a manner consistent with the published
recommendations, including recommended system requirements. Campbell
Scientific does not warrant that the software will meet licensee’s requirements
for use, or that the software or documentation are error free, or that the
operation of the software will be uninterrupted.
Campbell Scientific will either replace or correct any software that does not
perform substantially according to the specifications set forth in the instruction
manual with a corrected copy of the software or corrective code. In the case of
significant error in the installation media or documentation, Campbell
Scientific will correct errors without charge by providing new media, addenda,
or substitute pages. If Campbell Scientific is unable to replace defective media
or documentation, or if it is unable to provide corrected software or corrected
documentation within a reasonable time, it will either replace the software with
a functionally similar program or refund the purchase price paid for the
software.
All warranties of merchantability and fitness for a particular purpose are
disclaimed and excluded. Campbell Scientific shall not in any case be liable for
special, incidental, consequential, indirect, or other similar damages even if
Campbell Scientific has been advised of the possibility of such damages.
Campbell Scientific is not responsible for any costs incurred as a result of lost
profits or revenue, loss of use of the software, loss of data, cost of re-creating
lost data, the cost of any substitute program, telecommunication access costs,
claims by any party other than licensee, or for other similar costs.
This warranty does not cover any software that has been altered or changed in
any way by anyone other than Campbell Scientific. Campbell Scientific is not
responsible for problems caused by computer hardware, computer operating
systems, or the use of Campbell Scientific’s software with non-Campbell
Scientific software.
Licensee’s sole and exclusive remedy is set forth in this limited warranty.
Campbell Scientific’s aggregate liability arising from or relating to this
agreement or the software or documentation (regardless of the form of action;
e.g., contract, tort, computer malpractice, fraud and/or otherwise) is limited to
the purchase price paid by the licensee.
Table of Contents
PDF viewers: These page numbers refer to the printed version of this document. Use the
PDF reader bookmarks tab for links to specific sections.
1. Installation ................................................................1-1
1.1
1.2
1.3
1.4
System Requirements....................................................................... 1-1
Installation CD ................................................................................. 1-2
Web Setup File................................................................................. 1-3
Install Wizard................................................................................... 1-4
2. Quickstart .................................................................2-1
2.1
2.2
2.3
2.4
2.5
The Main Window ........................................................................... 2-1
Discover Devices ............................................................................. 2-2
Connect to a Device ......................................................................... 2-2
Download Data ................................................................................ 2-3
View Data ........................................................................................ 2-3
2.5.1 Data Viewing Tab ..................................................................... 2-3
2.5.2 Chart Viewing Tab.................................................................... 2-4
2.5.3 Map Viewing Tab ..................................................................... 2-5
3. Downloading Data....................................................3-1
3.1
Discovering a Device ....................................................................... 3-1
3.1.1 The Device List......................................................................... 3-1
3.2
Connecting to a Device .................................................................... 3-2
3.2.1 Connecting ................................................................................ 3-2
3.2.2 Pairing with a Device................................................................ 3-3
3.2.3 Disconnecting ........................................................................... 3-4
3.2.4 Connect Errors .......................................................................... 3-4
3.3
Setting Time ..................................................................................... 3-5
3.3.1 The Set Device Time Window.................................................. 3-5
3.3.1.1 Set to System Time ........................................................ 3-5
3.3.1.2 Set to Custom Time........................................................ 3-6
3.4
Synchronizing with a Device ........................................................... 3-6
3.4.1 Synchronizing ........................................................................... 3-7
4. Viewing Data ............................................................4-1
4.1
4.2
4.3
Using the Timeline........................................................................... 4-1
Showing / Hiding Zones................................................................... 4-4
Data Tab........................................................................................... 4-5
4.3.1 Records Display ........................................................................ 4-5
4.3.2 Point Options ............................................................................ 4-6
4.3.2.1 Find In Map View .......................................................... 4-6
4.3.2.2 Select All Rows.............................................................. 4-7
4.3.2.3 Removing Records ......................................................... 4-8
4.3.3 Export Menu ............................................................................. 4-9
4.4
Chart Tab........................................................................................ 4-10
4.4.1 Chart Tab Sections .................................................................. 4-10
4.4.2 Export Menu ........................................................................... 4-11
i
Table of Contents
4.5
Map Tab ......................................................................................... 4-13
4.5.1 Map View Sections ................................................................. 4-13
4.5.2 Creating a New Zone............................................................... 4-15
4.5.3 Zones List................................................................................ 4-17
4.5.4 Export Menu............................................................................ 4-18
4.5.5 Show in Google Earth ............................................................. 4-19
4.5.5.1 Zones ............................................................................ 4-20
4.5.5.2 Measurements............................................................... 4-20
4.5.6 Edit Zone Window .................................................................. 4-21
4.5.6.1 Zone Editing Tools ....................................................... 4-22
5. Settings and Configuration .................................... 5-1
5.1
5.2
Bluetooth Settings ............................................................................ 5-1
Device Settings................................................................................. 5-2
5.2.1 Saving Settings.......................................................................... 5-4
5.2.2 Loading Settings........................................................................ 5-6
5.3
Measurement Colors......................................................................... 5-7
5.3.1 Data Tab .................................................................................... 5-7
5.3.2 Chart Tab................................................................................... 5-7
5.3.3 Map Tab .................................................................................... 5-7
5.3.4 Changing Measurement Colors ................................................. 5-8
6. Terms ....................................................................... 6-1
6.1
6.2
6.3
Bluetooth Adapter ............................................................................ 6-1
Bluetooth Stack ................................................................................ 6-1
VWC................................................................................................. 6-1
7. Error Codes ............................................................. 7-1
7.1
7.2
7.3
7.4
7.5
7.6
7.7
7.8
7.9
7.10
Reporting an Error............................................................................ 7-1
Software Log Files ........................................................................... 7-1
(0x01) UserAbort ............................................................................. 7-3
(0x10) BTUnkownError ................................................................... 7-3
(0x11) BTStackError ........................................................................ 7-4
(0x12) BTSocketError ...................................................................... 7-4
(0x21) HydrocolNoResponse ........................................................... 7-6
(0x22) RemoteFileNotFound............................................................ 7-6
(0x25) InvalidPacket ........................................................................ 7-7
(0x26) UnexpectedResponse ............................................................ 7-7
8. Operating System Updater..................................... 8-1
8.1
8.2
8.3
Bluetooth Provider ........................................................................... 8-2
Discovering the Device .................................................................... 8-3
Sending an Operating System........................................................... 8-4
List of Tables
1-1.
1-2.
3-1.
4-1.
5-1.
7-1.
NET Framework 3.5 Minimum Requirements ................................. 1-1
HydroSense II Software Recommended Requirements.................... 1-1
Status Area States ............................................................................. 3-7
Data List ........................................................................................... 4-6
Default Measurement Colors............................................................ 5-8
Bluetooth Transmission Distance..................................................... 7-5
ii
Section 1.
Installation
1.1 System Requirements
HydroSense II Support Software is built on the .NET Framework 3.5, which
has the minimum system requirements listed in TABLE 1-1. NET Framework
3.5 Minimum Requirements (p. 1-1).
TABLE 1-1. NET Framework 3.5 Minimum Requirements
Operating
System
Windows XP SP2, Windows Vista, Windows 7, Windows
Server 2003
Windows Server 2008
Processor
400 MHz Pentium processor or equivalent
RAM
96 MB
Hard Disk
Up to 500 MB of available space may be required
Display
800 x 600, 256 colors
The software also makes use of resource intensive drawing libraries to display
charts and 2D plots. The recommended requirements to use these features are
listed in TABLE 1-2. HydroSense II Software Recommended Requirements
(p. 1-1).
TABLE 1-2. HydroSense II Software Recommended Requirements
Operating
System
Windows XP SP3, Windows Vista SP2, Windows 7 SP1
Windows Server 2003 SP2, Windows Server 2008 SP2
Processor
1.6 GHz Pentium 4 processor or equivalent
RAM
512 MB
Hard Disk
500 MB for the .NET framework
an additional 10 MB for the HydroSense II software
Display
800 x 600, 32 bit color
HydroSense II Support Software uses Bluetooth to communicate with the
HydroSense II display. A Bluetooth stack is required on the local PC to handle
traffic between software and Bluetooth hardware. Bluetooth hardware will be
either a USB dongle or a built-in chip.
1-1
Section 1. Installation
Supported Bluetooth Stacks
Microsoft (included with Windows XP SP2, Windows Vista, and Windows 7)
BlueSoleil (bundled in the form of BlueSoleil software with Bluetooth USB
dongles)
Toshiba (used by third parties, such as Dell and Sony, in laptops and USB
dongles)
Broadcom / Widcomm (one of the older stacks, also licensed to third parties)
1.2 Installation CD
An installation CD is supplied with the HydroSense II unit. The CD contains
the HydroSense II Support Software and the .NET Framework 3.5 for systems
that do not have this already installed.
To install the software, insert the CD into the PC CD-ROM drive. The setup
wizard should start automatically. If it does not, browse to the CD-ROM drive
in Windows® Explorer® and run setup.exe.
1-2
Section 1. Installation
If the .NET Framework 3.5 SP1 is not already installed, the wizard will prompt
to install it from the CD. Click Accept to continue.
The installation of .NET Framework 3.5 will take a couple of minutes. Once
the installation is complete, the install wizard will continue (SECTION 1.4
Install Wizard (p. 1-4)).
1.3 Web Setup File
Alternatively, HydroSense II Support Software can be downloaded from the
Downloads menu at www.campbellsci.com. The download does not include
the .NET Framework. To start the installation of the HydroSense II Support
Software, double-click on HydroSoft.exe.
If the .NET Framework 3.5 is not installed, the wizard will prompt to download
the framework from Microsoft’s website.
1-3
Section 1. Installation
Click Yes to open a browser to download and install the .NET Framework,
then run HydroSoft.exe again.
1.4 Install Wizard
The installation wizard begins with a welcome page:
Click Next to continue. The next page shows the default installation directory
for the software.
1-4
Section 1. Installation
In most cases, the default directory should be used.
This page also asks whether to install the software for the current user or for all
users on this PC. This decides whether the desktop shortcut and Start menu
shortcut will be visible to just the current user or to all users. Click Next to
continue.
Click Next on the next page to begin installing the software.
When installation is complete, close the wizard:
1-5
Section 1. Installation
A shortcut to the software is placed on the desktop and in the Start menu under
Programs > Campbell Scientific > HydroSense II. This Start menu group
contains two shortcuts.
HydroSense II Support Software
This shortcut will run the support software used to download and display data
from the HydroSense II. See SECTION 2. Quickstart (p. 2-1) for more
information.
Operating System Updater
This shortcut will run the HydroSense II firmware update facility. This is used
to send an updated operating system to the HydroSense II display unit. An OS
update is required only if a new operating system has been released to add
features or fix existing issues. See SECTION 8. Operating System Updater
(p. 8-1) for more information.
1-6
Section 2.
Quickstart
2.1 The Main Window
The main window has three areas.
1.
Toolbar — used to connect to devices and download data.
2.
Central area — contains the Data, Chart, and Map tabs. These tabs will
become visible when data are downloaded from the HydroSense II. More
information can be found in SECTION 4. Viewing Data (p. 4-1).
3.
Status bar — displays errors that may occur while connecting to a device.
On start up, the status bar in the lower portion of the window should not
show any errors. It should show the information icon, . If the software
does not detect any Bluetooth hardware on the local PC, an error will be
shown. See SECTION 7.5 (0x11) BTStackError (p. 7-4) for more
information.
2-1
Section 2. Quickstart
2.2 Discover Devices
Press the Discover button in the toolbar to start searching for devices.
Depending on your Bluetooth hardware, this search could take up to 30
seconds to complete and cannot be cancelled.
When discovery is complete, the first discovered device is displayed in the
Device List to the right of the Discover button. To view all discovered devices,
press the down arrow to the right of the device name.
2.3 Connect to a Device
Select the device that corresponds to the HydroSense II. Device name will be
“HYDxxxxx”, where xxxxx is the serial number of the display. This will
enable the Connect button. Press Connect to connect to the HydroSense II.
The first time the software connects to a specific HydroSense II, the user is
required to enter a pairing code for the device. All HydroSense II displays
have the pairing code 1234.
When connection is successful, remote battery voltage and clock are displayed
in the toolbar.
If the HydroSense II display clock needs updating, either wait for the first GPS
time sync or see SECTION 3.3 Setting Time (p. 3-5) for instructions. The
HydroSense II should have its battery replaced at 4.00 V; it will not power up
when the battery voltage reaches 3.60 V.
More information on connecting to a device and possible connection errors can
be found in SECTION 3.2 Connecting to a Device (p. 3-2).
2-2
Section 2. Quickstart
2.4 Download Data
If the HydroSense II has new measurement or zone data, notification will be
posted in the status area to the right of the Synchronise button.
To download new data, press the Synchronise button.
After the download is complete, the status area indicates that the measurements
and zones are now synchronized.
For more information on downloading data see SECTION 3.4 Synchronizing
with a Device (p. 3-6).
2.5 View Data
Downloading data from the HydroSense II will enable three tabs in the main
window that enable viewing HydroSense II data.
2.5.1 Data Viewing Tab
The Data tab displays a list of all measurements sorted by time of
measurement. Each row represents a single measurement and lists
•
the zone a measurement is located within
•
latitude and longitude of the measurement
•
details of the parameters measured
2-3
Section 2. Quickstart
The timeline in the lower portion of the tab is used to filter the data by
measurement time. The sliders on either side of the table are used to scroll
through the measurements.
For more information on how to use the data tab viewing options, see
SECTION 4.3 Data Tab (p. 4-5).
2.5.2 Chart Viewing Tab
The Chart tab plots measurements for a given zone (or group of zones) over
time. As the pointer is moved over the chart, time and soil moisture at the
pointer position are shown in the upper-right. If the pointer is moved close to a
measurement, an infotip will display the measurement details.
2-4
Section 2. Quickstart
By default, the chart displays all measurements. To view a chart for a specific
date range, clear the Select All Dates checkbox and use the timeline (timeline
is below the chart) to highlight a range of dates to display.
For more information on using the Chart tab and the timeline, see SECTION
4.4 Chart Tab (p. 4-10).
2.5.3 Map Viewing Tab
The Map tab displays measurements and zones on a two-dimensional plot.
Average moisture is calculated for each zone from the measurements within the
zone; the zone is colored accordingly. Moving the pointer over any point or
zone displays an infotip with more detailed information.
By default, all measured points are displayed in the map. The timeline
(timeline is below the map) is used to filter the displayed points by a given date
range.
The toolbox at the right of the window can be used to move and resize zones.
Double-click on a zone to set the zone radius or change the zone name.
For more information on using the Map tab, see SECTION 4.5 Map Tab (p. 413). For more information on moving and resizing zones, see SECTION
4.5.6.1 Zone Editing Tools (p. 4-22).
2-5
Section 2. Quickstart
2-6
Section 3.
Downloading Data
3.1 Discovering a Device
The main toolbar contains the Discover button and the list of known devices.
Press the Discover button in the toolbar to start searching for devices. The
HydroSense II should be in range of the PC and turned on.
Depending on the Bluetooth hardware, this search takes up to 20 seconds and
cannot be cancelled. During discovery, the status bar flashes a discovery
symbol to indicate that discovery is in progress.
When discovery is complete, the first discovered device is displayed in the
device list to the right of the Discover button.
3.1.1 The Device List
The device list contains all devices discovered in the current and previous
sessions.
Each HydroSense II is listed with its device name (HYD followed by the serial
number) in bold, and its Bluetooth address is printed in smaller font beneath.
Devices discovered in the current session are shown with a Bluetooth icon,
.
The software saves a list of devices previously discovered. They can be
selected directly from the list without a discovery step. These devices are
.
shown next to a folder icon,
If data have been previously downloaded from a particular HydroSense II,
selecting that device in the list will update the software data display area to
show data for that unit. The device list controls which device has its data
displayed in the software.
3-1
Section 3. Downloading Data
3.2 Connecting to a Device
3.2.1 Connecting
The Connect button controls connection to HydroSense II probes. If a device
is selected in the device list, the Connect button will be enabled.
Press the Connect button to connect to the device. The connection process
should take only a few seconds. The status bar will flash a Connect icon to
indicate that the connection is in progress.
The first time the software connects to a particular HydroSense II, a pairing
step is required. The pairing code is 1234. See SECTION 3.2.2 Pairing with a
Device (p. 3-3).
If the connection succeeds, an area next to the Connect button expands to show
HydroSense II clock and battery voltage.
The clock icon may be pressed to set HydroSense II time. This will open a
new window. For more information, see SECTION 3.3 Setting Time (p. 3-5).
If battery voltage is below 4.0 V, the batteries need replacing. The HydroSense
II will turn off if voltage drops to 3.6 V.
During the connection process, the software asks the HydroSense II if it has
any new data or zones. If the connection process is successful, this information
is used to update the status area to the right of the Synchronise button.
Synchronizing data with the device is discussed in SECTION 3.4
Synchronizing with a Device (p. 3-6).
3-2
Section 3. Downloading Data
3.2.2 Pairing with a Device
The first time the software connects to a specific HydroSense II, the user is
required to enter a pairing code for the device. For all HydroSense II displays,
the pairing code is 1234.
After pressing the Connect button, the Bluetooth stack on the local PC will ask
for the pairing code. The method used to ask for this code varies between
Bluetooth stacks. This page shows the procedure for the Microsoft stack
running on Windows 7.
A notification will appear in the notification area of the Windows Desktop
(lower-right).
Click the notification to open the "Add a device" window.
Enter the pairing code 1234, and then press Next.
3-3
Section 3. Downloading Data
Close the "Add a device" window by pressing the Close button. Windows will
install the necessary drivers to communicate with the HydroSense II; the
progress will be shown above the Windows task bar.
Once the installation is complete, the HydroSense software will connect to the
HydroSense II.
3.2.3 Disconnecting
The software does not need to be connected to a device to view downloaded
data.
The software does need to be connected to the HydroSense II display to
perform the following.
•
Download new measurements
•
Download new zones
•
Upload new or modified zones
•
Change settings
•
Set the HydroSense II display clock
Maintaining a Bluetooth connection consumes battery power. Disconnect and
power down the HydroSense II after a data download to conserve battery life.
All other software functions are available while disconnected.
3.2.4 Connect Errors
The following errors may occur when connecting to a device. Detailed
information on each error can be found in SECTION 7. Error Codes (p. 7-1).
3-4
•
BTUnkownError - an error has occurred during the connection and the
local Bluetooth stack did not specify the reason.
•
BTSocketError - there was an error creating a Bluetooth connection to the
device.
•
HydrocolNoResponse - a Bluetooth connection to the HydroSense II
display was created, but the device is not responding to commands from
the software.
Section 3. Downloading Data
3.3 Setting Time
Manually adjusting time and date is not normally necessary. GPS derived time
will override time and date set with this menu. The time setting facility is
generally used to set the clock when GPS synchronization is disabled or GPS
power is turned off.
3.3.1 The Set Device Time Window
When connected (SECTION 3.2.1 Connecting (p. 3-2)), HydroSense II time
appears next to the Connect button in the main toolbar.
Press the clock icon to open the Set Device Time window.
3.3.1.1 Set to System Time
By default, the window is configured to set the device time to the same time
and time zone as the local PC (Set to System Time option is selected).
With this option selected, the time and time zone edit boxes are disabled, but
will update once per second to the current system time.
Press the Set button to update the device with the current system time.
3-5
Section 3. Downloading Data
3.3.1.2 Set to Custom Time
To set HydroSense II time to a custom time or time zone, select the Set To:
option.
This enables the time and time zone edit boxes. Enter the custom date and time
into the edit boxes. To set the date using a calendar, press the drop down arrow
on the date edit box.
In the Item list, select the desired time zone.
Press the Set button to update the device with the custom time or time zone.
3.4 Synchronizing with a Device
The Synchronise and Settings buttons of the main toolbar are disabled until a
Bluetooth connection is made.
After connection, synchronization status information is placed to the right of
the Syncronise button. Status information shows whether data or zones need to
be downloaded from the HydroSense II, or if zones need to be uploaded.
3-6
Section 3. Downloading Data
The following table shows the possible states that may be shown in the status
area, and the action each performs.
TABLE 3-1. Status Area States
State
Action Performed
The latest record stored on the
device is newer than the latest
record stored on the PC.
The PC will download the new
records from the device.
The latest record stored on the
device is the same as the latest
record stored on the PC.
No action is needed.
The zones stored on the device
have changed since the last
synchronization. If the zones
stored on the PC have also
changed since the last
synchronization, device zone
changes take precedence and will
overwrite the zones stored on the
PC.
The PC will overwrite its zones
with those from the device.
Since the last synchronization, the
zones stored on the PC have
changed, but the zones on the
HydroSense II have not.
The device will overwrite its zones
with those from the PC.
The zones on the device match
those stored on the PC.
No action is needed.
3.4.1 Synchronizing
Press the Synchronise button to perform the download and upload actions
indicated in the status fields. The status display will change to show the
download and upload progress for each file on the device.
3-7
Section 3. Downloading Data
After synchronization is complete, the status display will show that data and
zones are synchronized.
The connection with the HydroSense II can be disconnected after
synchronization. Newly downloaded data can be viewed without an active
connection.
3-8
Section 4.
Viewing Data
4.1 Using the Timeline
The timeline shows an overview of water content over time.
The Data, Chart, and Map tabs use a common timeline to filter measurements
based on the time they were taken. The timeline is shown in the lower portion
of each tab.
By default, the timeline has the Select All Dates checkbox selected. This
means that all measurements will be displayed in the active tab.
To start filtering measurements by timestamp, clear the Select All Dates
checkbox. This will enable timeline control.
The following figure shows water content for the month before 4 July, 2011.
The length of time shown in the timeline is displayed in the upper-left (1
Month), and the ending date shown in the timeline is displayed in the upperright (04 July, 2011).
Part of the timeline around 13 June 2011 is highlighted to indicate points
currently shown in the main view. This highlighted area can be moved to the
left and right by clicking and dragging the scrollbar beneath the timeline.
Dragging the scrollbar all the way to one edge of the timeline will scroll the
timeline background to bring earlier (or later) points into view. Notice that the
timeline is adjusted such that data for only one month are shown.
Dragging the scrollbar to the far left of the screen adjusts the timeline such that
water content data for a month ending on 13 June are displayed.
4-1
Section 4. Viewing Data
The length of the highlighted area are changed by clicking and dragging the
sliders on either side of the selection.
Extending the highlighted area to cover more than 80% of the timeline will
cause the timeline to zoom out and a longer date range of data to be displayed.
Notice that the timeline now shows 3 months of data.
Likewise, reducing the length of the highlighted area to cover less than 20% of
the width of the timeline causes the timeline to zoom in and data from a
smaller date range to be shown.
Notice that the timeline is now showing 1 month of data. To stop filtering by
date and display all points, select the Select All Dates checkbox to disable
timeline control.
4-2
Section 4. Viewing Data
When large numbers of measurements are updated, the process may take a few
seconds. A loading icon will be displayed while the view is refreshed.
4-3
Section 4. Viewing Data
4.2 Showing / Hiding Zones
Zones menus in the Data and Chart tabs facilitate showing or hiding
measurements by zone.
By default, all zones are shown and listed in alphabetical order; clear the Select
All checkbox to enable individual zone checkboxes.
Clearing individual zone checkboxes will remove measurements from those
zones. If the Select All checkbox is cleared and no individual zones are
selected, no data are displayed.
The [Unspecified Zone] is a special zone that contains all the points that are not
located in any of the other zones. The [No GPS Lock] zone is a special zone
that contains all the points that were collected without positional information.
4-4
Section 4. Viewing Data
4.3 Data Tab
4.3.1 Records Display
The Data tab displays all records downloaded for the current device in detail.
The tab has three sections.
1.
Menu Bar
The menu bar has a Zones menu and an Export menu. The Zones menu allows
the user to display or hide measurements by zone. See SECTION 4.2 Showing
/ Hiding Zones (p. 4-4) for more information.
The Export menu allows the user to output a .csv file containing the
measurements currently in view. See SECTION 4.3.3 Export Menu (p. 4-9) for
more information.
2.
Data List
The data list contains measurements downloaded from the HydroSense II.
Measurements shown in the list can be filtered using the Zones menu or the
timeline.
Row color indicates a range of volumetric water contents. Colors default to red
for low soil water, yellow for midrange soil water, and green for high soil
water. For information on customizing colors, see SECTION 5.3 Measurement
Colors (p. 5-7).
4-5
Section 4. Viewing Data
The following columns are in the data list:
TABLE 4-1. Data List
Element
Description
TimeStamp
HydroSense time when the measurement was made
Record
Number
Record numbers range from 1 to 65535
Zone
Zone where this measurement is located
Latitude
Latitude (°N of the equator) where this measurement was
made
Longitude
Longitude (°E of the prime meridian) where this measurement
was made
Moisture ( % )
Volumetric water content (VWC) reported in percent (%).
Only water content is plotted on the Chart tab. Additional
raw measurements with units are shown in the Data tab
3.
Timeline
The timeline allows the user to filter the points in the data list based on when
the measurements were taken. By default, the Select All Dates checkbox is
selected and all measurements are displayed. For information using the
timeline, see SECTION 4.1 Using the Timeline (p. 4-1).
4.3.2 Point Options
4.3.2.1 Find In Map View
To locate a given point in the Map View, right click on the desired row
(multiple rows can also be selected) in the Data View and choose Find In Map
View. Alternatively, double clicking on the row will perform the same
function.
4-6
Section 4. Viewing Data
The Map View will appear and the selected points will be highlighted with
cross hairs for 3 seconds.
The map will automatically pan to ensure all of the selected points are visible.
4.3.2.2 Select All Rows
All rows in the Data View can be selected by right clicking anywhere in the
data list and choosing Select All.
This will select all rows in the current view (it will not select rows which are
currently hidden by the choice of visible zones or the date range).
4-7
Section 4. Viewing Data
4.3.2.3 Removing Records
Unwanted measurements are removed by right-clicking on the measurement
row and selecting the "Remove selected points" command.
The software will prompt for confirmation of the removal. Once a
measurement is removed from the list, it cannot be recovered.
Multiple measurements can be removed by holding the CTRL key and
selecting the desired rows, and then right-clicking and choosing the “Remove
selected points” command.
4-8
Section 4. Viewing Data
4.3.3 Export Menu
The Export menu can be found at upper-left of the Data tab
The menu contains a command to export the measurements listed in the Data
tab to a .csv file. A .csv file can be opened in Excel® or similar spreadsheet
applications.
First, select the appropriate range of dates from the timeline in the Data tab.
Click the “To CSV (Excel)” command from the Export menu. A Save As
dialog box will prompt where to save the .csv file. Choose a location and press
Save. All columns shown in the Data tab will be exported to the .csv file.
4-9
Section 4. Viewing Data
4.4 Chart Tab
4.4.1 Chart Tab Sections
The Chart tab plots volumetric water content (VWC) from each measurement
against time. The tab has three sections.
1.
Menu Bar
The menu bar has a Zones menu and an Export menu. The Zones menu allows
the user to display or hide measurements by zone. See SECTION 4.2 Showing
/ Hiding Zones (p. 4-4) for more information.
The Export menu allows the user to output a .csv file containing the
measurements currently in view. See SECTION 4.3.3 Export Menu (p. 4-9) for
more information.
2.
Chart
The chart plots volumetric water content as a function of time. The plot can be
scrolled using the timeline, and the measurements included in the plot can be
filtered using the Zone menu. The chart plots volumetric water content as a
function of time. The plot can be scrolled using the timeline, and the
measurements included in the plot can be filtered using the Zone menu.
Moving the pointer over the chart displays a vertical line that will follow the
pointer to indicate the volumetric water content at the pointer position. The
text at the upper-right of the plot shows time of the point over which the
pointer is currently paused, with the associated interpolated water content.
Interpolated water content is the water content expected given the
measurements directly before and after the pointer position. The text at upperleft of the plot shows the range of dates currently shown in the plot. If the
pointer moves close to a measurement, the pointer changes to dark blue and an
4-10
Section 4. Viewing Data
infotip is displayed listing time the measurement was made, VWC in percent
(%), and the zones to which the measurement belongs.
The background of the chart is a gradient of color defaults used in the
HydroSense II software. This is the coloring scheme used as the background
for rows in the Data tab and used to color measurements and zones in the Map
tab. To change these colors, see SECTION 5.3 Measurement Colors (p. 5-7).
3.
Timeline
The timeline is used to scroll the chart as well as zoom in and zoom out. For
more information on how to use the timeline, see SECTION 4.1 Using the
Timeline (p. 4-1).
4.4.2 Export Menu
The Export menu can be found at the upper-left of the Chart tab.
The Export menu facilitates exporting the current chart to a color or black and
white image file. Clicking on either of the commands opens a Save As dialog
box to choose the location to which to export the file. The file can be saved as
.png, .jpg, or .bmp. Following are samples of the two image outputs.
4-11
Section 4. Viewing Data
Sample Chart Export (Color)
Sample Chart Export (Black and White)
4-12
Section 4. Viewing Data
4.5 Map Tab
4.5.1 Map View Sections
The Map tab plots measurements and zones on a 2D map and colors them
according to aggregate measurement values. The Map tab does not provide the
option to import a background image on which to plot, but it can export the
current map view to Google Earth for viewing against satellite imagery. The
Map tab has three areas.
1.
Menu Bar
The Zones menu lists all zones plotted in the main map and allows the user to
zoom to a particular zone by double-clicking on its entry in the list. See
SECTION 4.5.3 Zones List (4-17) for more information.
The Export menu allows the user to export the current view to either KML
format to import into Google Earth, or GPX format, which supports many
mapping applications. See SECTION 4.5.4 Export Menu (p. 4-18) for more
information.
2.
Map
The date range of the points displayed is shown at the upper-left of the main
map. This is the date range which has been chosen with the timeline.
The size of the current viewing area, in meters, is displayed at the bottom lefthand side of the map. The size of the map can be changed by zooming in and
out or by resizing the main window. The area is expressed as width by height.
4-13
Section 4. Viewing Data
A toolbar is located on the right of the map. It contains tools to change zone
sizes and positions. See SECTION 4.5.6.1 Zone Editing Tools (p. 4-22) for
instructions on how to use this toolbar.
A zoom slider is located on the left-hand side of the main map. This can be
used to change the current zoom level in increments by clicking the + and buttons or continuously zooming in by using the slider.
If Google Earth is installed on the local computer, clicking the button at the
lower-right of the map will show the contents of the view in Google Earth.
More information on this can be found in SECTION 4.5.5 Show in Google
Earth (p. 4-19).
Zones
Zones are shown to scale on the map. The relative sizes of the zones match the
diameters chosen on the HydroSense II. Each zone is colored according to the
average VWC of all points contained in the zone. Colors used to represent
different levels of VWC can be changed as described in SECTION 5.3.4
Changing Measurement Colors (p. 5-8).
Pausing the pointer over a zone will produce an infotip that lists the average
VWC of this zone and the zone diameter and number of contained points. The
diameter of the zone is shown in brackets next to the zone name.
Right-clicking on the zone shows the Zone Context menu, which has the
following commands:
4-14
•
Edit — opens the Edit Zone window where the zone name and diameter
can be changed. For more information, see SECTION 4.5.6 Edit Zone
Window (p. 4-21).
•
Zoom To — zoom in to the current map view to show only the selected
zone.
•
Remove — removes the zone from the software and from the HydroSense
II device on the next synchronization. A dialog box will ask the user to
confirm this action.
Section 4. Viewing Data
Points
Measurements are shown on the map as small cross marks. These cross marks
are not drawn to scale and do not change size during zooming. Each cross is
colored according to the VWC for the measurement. The colors used to
represent different levels of VWC can be changed as described in SECTION
5.3.4 Changing Measurement Colors (p. 5-8).
Pausing the pointer over a cross mark will produce an infotip listing the
timestamp, VWC and zones containing the measurement.
Right clicking on the zone shows the zone context menu, with the following
options:
•
The Find in Data View menu option will display the Data View and select
the appropriate row for this measurement. This is the default action for a
point and double clicking on the point will perform the same function.
•
The Create New Zone menu option will create a new zone centered on the
selected point (see SECTION 4.5.2 Creating a New Zone (p. 4-15)).
3.
Timeline
The timeline allows the user to filter the measurements shown in the map based
on when measurements were taken. By default, the Select All Dates checkbox
is selected, and all measurements are displayed. For more information on how
to use the timeline, see SECTION 4.1 Using the Timeline (p. 4-1).
4.5.2 Creating a New Zone
New zones can be created from the Map View by right clicking on an empty
area on the map or on an existing point, then choosing Create New Zone.
4-15
Section 4. Viewing Data
This will create a new zone centered on the cursor position or on the selected
point.
The name of the zone will be automatically generated and the radius will be set
to a quarter of the Map View height (with a minimum of 3 meters). Double
click the new zone to change the name and size or use the Zone Editing Tools
to resize or move the zone.
The new zone will not yet exist on the HydroSense II hand held unit; it will be
uploaded to the unit on the next Synchronization.
4-16
Section 4. Viewing Data
4.5.3 Zones List
The Zones list menu can be found at the upper-left of the Map tab.
This menu lists the zones stored on the HydroSense II with the number of
points in each zone. The zones will be listed in alphabetical order. Doubleclick on a zone to zoom to that zone in the Map tab.
Zone editing commands are available by right-clicking on the zone in the Map
tab. See SECTION 4.5 Map Tab (p. 4-13) for more information.
4-17
Section 4. Viewing Data
4.5.4 Export Menu
The Export menu can be found at the upper-left of the Map tab.
The menu facilitates exporting map data to one of two formats. Clicking on
either of the commands will open a Save As dialog box to choose the location
of the exported file. Only the points currently visible on the map will be
exported. To export all points, select the Select All Dates checkbox in the
timeline.
KML
KML is the Google Earth file format. The .kml file contains both zone and
measurement information. Zones are displayed as colored circles;
measurements will be displayed as colored drawing pins. The color of the
circles and drawing pins will be the same as the colors shown in HydroSense II
Support Software.
GPX
This is a standard GIS format used by many mapping packages. Google Earth
supports GPX files, but the GPX format does not allow for drawing shapes, so
only measurement information is stored in the exported GPX file. Each
measurement is stored as a GPX waypoint with a timestamp. The VWC
measurement is stored in the waypoint description.
4-18
Section 4. Viewing Data
4.5.5 Show in Google Earth
The Show in Google Earth button is located at the lower-right of the Map tab.
This button is visible but disabled if Google Earth is not installed.
Clicking this button will open Google Earth and display the currently visible
zones and measurements against Google Earth satellite imagery.
4-19
Section 4. Viewing Data
4.5.5.1 Zones
Zones are displayed to scale as colored circles. Circle color is determined by
the average VWC of all points in a zone. Click the zone to view an infotip
with more information about the zone.
4.5.5.2 Measurements
Measurements are displayed as pin markers in Google Earth. Each marker will
be colored according to the VWC measured at that point. Click on one of the
markers to view an infotip with more information about the measurement.
4-20
Section 4. Viewing Data
4.5.6 Edit Zone Window
The Edit Zone window can be displayed by double-clicking a zone in the
HydroSense Support Software map or right-clicking the zone and choosing the
Edit command.
Note that the Set button will be disabled until a zone setting has been changed.
The following zone settings can be changed and saved by pressing the Set
button. The Set button will be disabled until a change is made to the zone
settings. Any changes made to zones on the local PC will be uploaded to the
HydroSense II on the next synchronization.
Name
This field is used to name the zone in the software and on the HydroSense II
handheld display. The maximum length of the name is 15 characters.
4-21
Section 4. Viewing Data
Radius
This field specifies the radius of the zone in meters. This field only accepts
numeric characters (numbers and the period character “.”). The minimum
allowable zone radius is 3 m.
Centre Latitude and Centre Longitude cannot be edited from the Edit Zone
Settings window. To change the location of a zone, use the Move Zone tool in
the map as described in SECTION 4.5.6.1 Zone Editing Tools (p. 4-22).
4.5.6.1 Zone Editing Tools
The toolbar at upper-right of the map contains tools to control map position
and edit zones.
1.
Drag Mode
By default, the hand icon is selected, so the map is in drag mode by default.
Clicking and dragging anywhere on the map pans the view. Moving the mouse
wheel while pausing over the map zooms the view in and out.
2.
Move Mode
Clicking the move tool puts the map in Move Mode. Clicking and dragging on
any zone makes the zone move with the pointer. This tool is used to reposition
zones on the map.
4-22
Section 4. Viewing Data
While dragging, the position of the pointer on the map is displayed in the
upper-right of the map. An infotip is displayed to show the number of
contained points and average moisture for the current zone position.
Right-clicking anywhere on the map, or selecting the hand tool from the
toolbox, puts the map back into Drag Mode.
3.
Resize Mode
Clicking the resize tool puts the map in Resize mode. Clicking and dragging
on any zone will increase or decrease its radius with the position of the pointer.
This tool can be used to resize zones on the map.
While dragging, an infotip will show the current radius of the zone in meters
with the number of contained zones and the average moisture at this zone size.
Right-clicking anywhere on the map or selecting the hand tool from the
toolbox puts the map back into Drag Mode.
4.
Zoom-to-Extents
Clicking the zoom-to-extents button will re-center the view so that all points
for the selected date range are visible.
4-23
Section 4. Viewing Data
4-24
Section 5.
Settings and Configuration
5.1 Bluetooth Settings
The Bluetooth Adapters window can be accessed from the Options menu in the
main window.
The window shows a list of all available Bluetooth adapters on the local PC.
The Bluetooth adapter currently being used by the HydroSense II software is
shown in bold. If there is more than one Bluetooth adapter on the local
computer, the extra adapters are shown in normal font in the list.
Each adapter is listed in the following format:
Adapter Name (Adapter Bluetooth Address) | Bluetooth Stack Used
To use a different adapter, select the adapter in the list and press the Activate
button. The new adapter is shown in bold. This setting is saved to disk so that
this adapter will be used the next time the software is run.
5-1
Section 5. Settings and Configuration
If the local PC does not have Bluetooth adapters connected, the following
window will be displayed.
See SECTION 7.5 (0x11) BTStackError (p. 7-4) for more information.
5.2 Device Settings
Settings for the HydroSense II can only be accessed when a Bluetooth
connection has been established. Click the Settings button in the main toolbar.
The software will first download the settings from the device.
5-2
Section 5. Settings and Configuration
Then the Device Settings Window will be displayed.
The device settings shown in the window will depend on the current version of
the operating system. The settings in the preceding figure are for the first
released version of the HydroSense II display operating system.
5-3
Section 5. Settings and Configuration
Move the pointer over the labels at the left of the screen to see more
information about each setting.
Change settings using the list boxes and sliders. The Apply button will be
disabled until a setting is changed. Press Apply to save the settings to the
HydroSense II.
After pressing Apply, the main window will show the settings file being
uploaded to the HydroSense II.
5.2.1 Saving Settings
During a firmware upgrade, the device settings of the HydroSense II will be
lost. The Device Settings window can be used to save the settings before the
upgrade.
5-4
Section 5. Settings and Configuration
Open the Device Settings window, then click the Save button.
Choose a location on the local PC to save the settings in an .xml file, then click
Save.
5-5
Section 5. Settings and Configuration
5.2.2 Loading Settings
Open the Device Settings window, then click the Load button.
Browse to the location of the settings .xml file on the local computer and click
Open.
5-6
Section 5. Settings and Configuration
The window will be updated with the saved settings. Press the Apply button to
update the HydroSense II display with these settings.
5.3 Measurement Colors
HydroSense II Support Software provides three ways to visualize data: Data
tab, Chart tab and Map tab. In each tab, colors are used to represent the value
of volumetric water content (VWC) from a measurement.
5.3.1 Data Tab
The background of each data record is colored based on the VWC measured at
that point.
5.3.2 Chart Tab
The background of the chart is colored with bands to show colors used for each
level of VWC.
5.3.3 Map Tab
Zones in the map are colored based on the average VWC of all the
measurements located within that zone.
Measurements are colored based on the VWC measured at that point.
5-7
Section 5. Settings and Configuration
5.3.4 Changing Measurement Colors
The default rules for deciding on the measurement color are shown in TABLE
5-1. Default Measurement Colors.
TABLE 5-1. Default Measurement Colors
Moisture Range
Color
0% < Moisture < 10%
Red
10% < Moisture < 20%
Light Red
20% < Moisture < 30%
Orange
30% < Moisture < 40%
Light Green
40% < Moisture < 50%
Green
These color levels can be customized. Click the Options menu in the main
window, and choose Reading Colors.
5-8
Section 5. Settings and Configuration
The window contains six edit boxes and five color buttons.
Each color button is positioned between two edit boxes. The values in the edit
boxes represent the upper and lower VWC limits for the reading color shown
on the color button between them.
In the default configuration, the color RED is positioned between the values 0
and 10. This means that measurements between 0% and 10% VWC are
assigned the color RED.
To change the levels at which colors begin and end, edit the values in the edit
boxes. The preview at the right of the window will update automatically. The
edit boxes will accept only numeric digits and will show a red outline when an
invalid entry has been made.
The 0% and 50% edit boxes are disabled; these represent the minimum and
maximum output from the sensor and cannot be edited.
5-9
Section 5. Settings and Configuration
To change the colors displayed, click the desired color button to open a
selection dialog box.
Click one of the colors in the selection dialog box. The dialog box will close,
and the selected color button will update its background to the selected color.
To close the dialog box without making a selection, click anywhere else in the
Reading Colors window.
5-10
Section 5. Settings and Configuration
At the right of the Reading Colors window is a sample chart background.
This sample background updates automatically when changes are made to the
values and colors on the left. It shows the background to be used for the Chart
tab given the current selections.
Press the Reset to Defaults button to revert the reading colors to the factory
default selections (shown in the preceding figures).
Press the Close button to save changes and return to the main window.
5-11
Section 5. Settings and Configuration
5-12
Section 6.
Terms
6.1 Bluetooth Adapter
The Bluetooth adapter is a hardware device connected to the local PC that
transmits and receives radio signals required for Bluetooth communications.
On desktop computers, the adapter is usually a USB device that connects to a
USB port on the computer. If the HydroSense II Support Software is reporting
a BTStackError, check that the USB device is firmly inserted into a USB port
on the PC. The Bluetooth stack on the computer should recognize that the
device is attached.
On laptop computers, the adapter is often built into the laptop hardware so that
an extra USB adapter is not required. These laptop computers will have an
option to enable/disable the internal adapter. Usually, this function is
performed by a special key on the laptop keyboard or an extra sliding switch on
the side of the laptop. If the software is reporting a BTStackError, check that
the internal Bluetooth adapter is enabled using the hotkey or switch.
6.2 Bluetooth Stack
The term Bluetooth stack refers to the collection of code on a PC which
handles Bluetooth traffic.
HydroSense II Support Software supports the four major Bluetooth stacks
currently on the market: Microsoft, BlueSoleil, Toshiba and Broadcom.
6.3 VWC
VWC is an acronym for volumetric water content. This is a measure of the
volume of water present in soil expressed as a percentage of the total volume.
A VWC of 20% indicates that the water fraction is 20% the soil by volume.
6-1
Section 6. Terms
6-2
Section 7.
Error Codes
7.1 Reporting an Error
The following information is required when reporting an error code to
Campbell Scientific.
1) Error Code
For example: BTStackError (0x11)
To find out more information on a particular error code, prompt an infotip by
pausing the pointer over the error, or click More Info.
2) Steps to Reproduce the Error
For example:
1. Pressed the Discover button to discover the HydroSense II.
2. Selected the HydroSense II device from the list.
3. Pressed Connect.
4. Connection failed with the error BTUnkownError.
Please indicate whether these steps, prior to the error, had worked as expected.
3) Bluetooth Adapter Make and Model
Please supply the make and model number of the Bluetooth adapter if using a
desktop computer. Supply the laptop make and model number if using a laptop
computer.
4) Log Files
See SECTION 7.2 Software Log Files (p. 7-1) for information on locating the
Bluetooth and application log files.
7.2 Software Log Files
If you receive an error code, please follow the instructions in SECTION 7.1
Reporting an Error (p. 7-1) to notify the local HydroSense II distributor of the
issue. To make identifying the cause of the error easier, please attach the
communication and application logs to your correspondence.
7-1
Section 7. Error Codes
These logs are located in the working directory of the software which can be
opened from the options menu in the main window.
The working directory contains three folders; data, logs and xml.
The data folder contains records and zones downloaded from each HydroSense
II stored in a raw binary format. These files can only be opened by the
HydroSense II software. Use the Export to CSV option in the Data View to
view records in Excel.
The xml folder contains configuration information for the HydroSense II
software.
The logs folder contains two log files; bluetooth.log and application.log.
The Bluetooth log file records the details of the last communication attempt
with a HydroSense II device.
The application log file contains start-up information and any program errors
since the last time the software was started.
When reporting an error, please email blueooth.log and application.log to your
HydroSense II distributor.
7-2
Section 7. Error Codes
7.3 (0x01) UserAbort
User aborted the operation.
This error is shown when a connection or synchronization attempt is cancelled
by clicking the Cancel button.
This error does not normally indicate a problem with communications;
however, if it is displayed without the Cancel button being pressed, and it
prevents normal operation of the software, please contact Campbell Scientific.
7.4 (0x10) BTUnkownError
An unknown error has occurred during Bluetooth communications.
This error is shown when communication with the HydroSense II has failed
and the Bluetooth driver on the local computer did not specify the cause of the
failure.
If this error has occurred, attempt to reproduce the error a second time by
following the same steps that resulted in the first error.
If the error is confirmed, please report the error to Campbell Scientific with the
steps required to reproduce the error.
7-3
Section 7. Error Codes
7.5 (0x11) BTStackError
No supported Bluetooth stack found on this computer.
The software did not find a compatible Bluetooth stack on the local PC. This
will usually occur on a desktop machine where the Bluetooth adapter has not
been connected or on a laptop where Bluetooth has been disabled.
First, check that the Bluetooth adapter is connected via a USB port, or that
Bluetooth has been enabled if using a laptop. Most new laptops have an
external button or a keyboard key to toggle Bluetooth.
If the Bluetooth adapter is connected, and Bluetooth is turned on, check
whether Windows has recognized the Bluetooth adapter. If Windows has
recognized the Bluetooth adapter, a Bluetooth icon should be displayed in the
Windows notification area.
The Bluetooth icon should be shaded blue. If it is shaded grey or is missing,
Windows has not recognized the Bluetooth hardware. Please contact the
supplier of your Bluetooth hardware for assistance.
If the Bluetooth icon is present, then Windows has recognized the Bluetooth
hardware, but HydroSense II Support Software has not. Please report the issue
to Campbell Scientific.
7.6 (0x12) BTSocketError
Could not establish a connection to the HydroSense II.
This error occurs when the Bluetooth adapter on the local PC is not able to
create a connection to the HydroSense II. This can be caused by the device
being out of range, or not responding to Bluetooth requests.
7-4
Section 7. Error Codes
Try the following steps to rectify the issue:
NOTE
Make sure the HydroSense II is powered on. Check that the
display is on and responsive.
Make sure that the HydroSense II is within range of the PC. The maximum
distance that the display can be situated away from the PC depends on the class
of the Bluetooth adapter used by the PC, as shown in TABLE 7-1. Bluetooth
Transmission Distance (p. 7-5).
TABLE 7-1. Bluetooth Transmission Distance
Bluetooth Class
Maximum Distance
Class 1
5m
Class 2
10 m
Class 3
100 m
Press the Discover button in the software again and check that a Bluetooth
symbol is shown next to the device serial number.
If a folder icon is shown instead, the software did not detect the device during
the discovery process. Restart the PC software and the HydroSense II and then
attempt another discovery.
If the device is still not discovered by the software, or if the device is being
discovered but cannot establish a connection, please report the issue to
Campbell Scientific.
7-5
Section 7. Error Codes
7.7 (0x21) HydrocolNoResponse
Did not receive a response from the HydroSense II.
The software did not receive a response to a request sent via Bluetooth. This
means that the Bluetooth connection was successfully connected, but
communications after the initial connection failed.
Failure may be caused by:
•
Another device in the area is accepting Bluetooth connections with a name
beginning with the letters "HYD". Check that the serial number of the
currently selected device in the software (the 5 digits after HYD) matches
the serial number printed on the HydroSense II. If multiple HydroSense II
units are within Bluetooth range, turn off all but one.
•
The HydroSense II has been taken out of Bluetooth range after the initial
connection. Ensure that the HydroSense II is well within the Bluetooth
range specified by the Bluetooth adapter on the local PC.
•
There is a fault with the HydroSense II or the PC software. If the No
Response error can be reproduced a second time, and the preceding steps
do not fix the issue, please report this to Campbell Scientific.
7.8 (0x22) RemoteFileNotFound
Remote file not found.
Data and zone information are stored in files on the HydroSense II. During
synchronization, the software downloads these files from the device. If this
error occurs, it means that the remote device does not recognize the file the
software is asking for.
This can be caused by an older version of the software communicating with a
device with new firmware. Please visit www.campbellsci.com to check
whether an updated software version is available.
If the latest version of the software is being used, please report the issue to
Campbell Scientific.
7-6
Section 7. Error Codes
7.9 (0x25) InvalidPacket
Invalid packet received.
The software has received a response from the remote that is either the wrong
length or has an incorrect format.
This can be caused by an older version of the software communicating with a
device with new firmware. Please visit www.campbellsci.com to check
whether an updated software version is available.
The error can also be caused by a weak Bluetooth connection with the remote
device. Ensure that the device is well within the maximum distance quoted by
the Bluetooth adapter on the local machine. The maximum communication
distances for Bluetooth adapters are listed in TABLE 7-1. Bluetooth
Transmission Distance.
If the error persists, please contact Campbell Scientific.
7.10 (0x26) UnexpectedResponse
Unexpected response received from the device.
The software has received a properly formatted response from the HydroSense
II, but it is not the response that the software was expecting. This can be
caused by an older version of the software communicating with a device with
new firmware. Please visit www.campbellsci.com to check whether an updated
software version is available.
If the latest version of the software is being used, please report the issue to
Campbell Scientific.
7-7
Section 7. Error Codes
7-8
Section 8.
WARNING
Operating System Updater
Sending an operating system to the HydroSense II will
permanently delete all measurements and zones saved
on the device. Please ensure that the HydroSense II is
synchronized with the PC software before sending a
new operating system. This will save all of the
HydroSense II’s data points and zones on to the PC.
The software includes a facility to update the operating system on the
HydroSense II. This can be run from the Operating System Updater shortcut
under the Campbell Scientific > HydroSense II group in the Windows Start
menu.
8-1
Section 8. Operating System Updater
8.1 Bluetooth Provider
The facility uses Bluetooth to transfer a new operating system to a HydroSense
II display. The Bluetooth provider used is shown in the upper portion of
screen. A Bluetooth provider refers to either a USB dongle or a built-in USB
chip in a laptop. If no Bluetooth provider is found, the following screen will be
displayed.
Make sure that Bluetooth is enabled on the local PC. Bluetooth can be toggled
using an external switch on a laptop or a special function key on the keyboard.
Bluetooth can also be toggled using the Bluetooth icon in the Windows
notification area. If Bluetooth is enabled and working with other devices and
the error in the preceding figure is still displayed, please contact Campbell
Scientific.
If multiple Bluetooth providers are available, click the browse button next to
the current provider to select a different provider:
The currently selected provider will appear in bold in the list. To activate a
different provider, double-click on its name, or select the provider and press the
Activate button. Then close the window using the Close button.
8-2
Section 8. Operating System Updater
8.2 Discovering the Device
To send an operating system to the device, it must be powered on in “boot
loader” mode. The procedure to do so is as follows:
•
Make sure the HydroSense II is turned off
•
Press and hold the up arrow button
•
With the up arrow still depressed, press and hold the power button for two
seconds
The HydroSense II will power on in “boot loader” mode and flash the LCD
display.
The device will remain in this mode for two minutes. Return to the software
and press the Discover button. The device should be displayed with its serial
number.
8-3
Section 8. Operating System Updater
8.3 Sending an Operating System
Select the device, and then press the Send Firmware button.
Before choosing a firmware to send to the device, a warning dialog is shown as
below:
Ensure that all data points and zones on the device have been synchronized
with the PC software before continuing.
Press Cancel to return to the Operating System Updater and cancel the send
operation.
Press OK to agree to remove all saved data points and zones from the device
during the operating system update. Note that any previous zones stored by the
8-4
Section 8. Operating System Updater
PC software can be re-uploaded to the device by performing synchronization
with the device immediately after the update is completed.
A file browser will open allowing you to select the new operating system.
When a new operating system becomes available, it will be listed at
www.campbellsci.com/downloads. It is this file that should be selected in the
file browser.
Click the Open button to begin the transfer. The HydroSense II will flash the
LCD display rapidly to indicate a transfer is in progress.
8-5
Section 8. Operating System Updater
The device will first erase the old operating system. This process takes about
30 seconds to complete.
When the old operating system is erased, the facility will transfer the new
operating system to the device. This process takes about 90 seconds to
complete. A progress bar reports the transfer progress.
8-6
Section 8. Operating System Updater
If there is a Bluetooth error while transferring the operating system, the error
will be shown below the progress bar. The HydroSense II will turn off, and the
operating system transfer will fail. At this point, the HydroSense II will not
power normally on as it has an incomplete operating system. The device can
still be powered on in “boot loader” mode. In event of an error, repeat the
operating system transfer procedure. If the error continues, please contact
Campbell Scientific.
Once the transfer is complete, the HydroSense II display will power off and the
update facility will display a message indicating the transfer was successful.
The HydroSense II display can now be powered normally.
Before storing data points on the device, perform a Synchronise with the
HydroSense II. This will upload the zones stored on the PC to the HydroSense
II, as the device zones would have been cleared during the upgrade process.
8-7
Section 8. Operating System Updater
8-8
Campbell Scientific Companies
Campbell Scientific, Inc. (CSI)
815 West 1800 North
Logan, Utah 84321
UNITED STATES
www.campbellsci.com • [email protected]
Campbell Scientific Africa Pty. Ltd. (CSAf)
PO Box 2450
Somerset West 7129
SOUTH AFRICA
www.csafrica.co.za • [email protected]
Campbell Scientific Australia Pty. Ltd. (CSA)
PO Box 8108
Garbutt Post Shop QLD 4814
AUSTRALIA
www.campbellsci.com.au • [email protected]
Campbell Scientific do Brazil Ltda. (CSB)
Rua Luisa Crapsi Orsi, 15 Butantã
CEP: 005543-000 São Paulo SP BRAZIL
www.campbellsci.com.br • [email protected]
Campbell Scientific Canada Corp. (CSC)
11564 - 149th Street NW
Edmonton, Alberta T5M 1W7
CANADA
www.campbellsci.ca • [email protected]
Campbell Scientific Centro Caribe S.A. (CSCC)
300 N Cementerio, Edificio Breller
Santo Domingo, Heredia 40305
COSTA RICA
www.campbellsci.cc • [email protected]
Campbell Scientific Ltd. (CSL)
Campbell Park
80 Hathern Road
Shepshed, Loughborough LE12 9GX
UNITED KINGDOM
www.campbellsci.co.uk • [email protected]
Campbell Scientific Ltd. (France)
3 Avenue de la Division Leclerc
92160 ANTONY
FRANCE
www.campbellsci.fr • [email protected]
Campbell Scientific Spain, S. L.
Avda. Pompeu Fabra 7-9, local 1
08024 Barcelona
SPAIN
www.campbellsci.es • [email protected]
Please visit www.campbellsci.com to obtain contact information for your local US or international representative.