AUTOMAZIONI A BRACCIO PER CANCELLI A BATTENTE

GB

ARM AUTOMATIONS FOR SWING GATES

E

P

F

D

AUTOMATIONS A BRAS POUR PORTAILS BATTANTS

ARM AUTOMATIONEN FUER FLUGELGITTERTIRE

AUTOMATIZACIONES A BRAZO PARA PORTONES CON BATIENTE

AUTOMATIZAÇÕES DE BRAÇO PARA PORTÕES DE BATENTE

D811296 ver. 07 30/07/07

8

027908 1 7 1 9 9 3

IGEA

ISTRUZIONI D’USO E DI INSTALLAZIONE

INSTALLATION AND USER’S MANUAL

INSTRUCTIONS D’UTILISATION ET D’INSTALLATION

INSTALLATIONS-UND GEBRAUCHSANLEITUNG

INSTRUCCIONES DE USO Y DE INSTALACION

INSTRUÇÕES DE USO E DE INSTALAÇÃO

Via Lago di Vico, 44

36015 Schio (VI)

Tel.naz. 0445 696511

Tel.int. +39 0445 696533

Fax 0445 696522

Internet: www.bft.it

E-mail: [email protected]

INSTALLATION MANUAL ENGLISH

Thank you for buying this product. Our company is sure that you will be more than satisfied with the product’s performance.

Carefully read the “ WARNINGS” pamphlet and the “INSTRUCTION BOO-

KLET” which are supplied together with this product, since they provide important information regarding the safety, installation, use and maintenance of the product. This product complies with recognised technical standards and safety regulations. We declare that this product is in conformity with the following European Directives: 73/23/ EEC, 89/336/EEC, 98/37/EEC and subsequent amendments.

1) GENERAL SAFETY

WARNING! An incorrect installation or improper use of the product can cause damage to persons, animals or things.

• The “ Warnings” leaflet and “Instruction booklet” supplied with this product should be read carefully as they provide important information about safety, installation, use and maintenance.

• Scrap packing materials (plastic, cardboard, polystyrene etc) according to the provisions set out by current standards. Keep nylon or polystyrene bags out of children’s reach.

• Keep the instructions together with the technical brochure for future reference.

• This product was exclusively designed and manufactured for the use specified in the present documentation. Any other use not specified in this documentation could damage the product and be dangerous.

• The Company declines all responsibility for any consequences resulting from improper use of the product, or use which is different from that expected and specified in the present documentation.

• Do not install the product in explosive atmosphere.

• The construction components of this product must comply with the following European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subsequent amendments. As for all non-EEC countries, the abovementioned standards as well as the current national standards should be respected in order to achieve a good safety level.

• The Company declines all responsibility for any consequences resulting from failure to observe Good Technical Practice when constructing closing structures (door, gates etc.), as well as from any deformation which might occur during use.

• The installation must comply with the provisions set out by the following

European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subsequent amendments.

• Disconnect the electrical power supply before carrying out any work on the installation. Also disconnect any buffer batteries, if fitted.

• Fit an omnipolar or magnetothermal switch on the mains power supply, having a contact opening distance equal to or greater than 3,5 mm.

• Check that a differential switch with a 0.03A threshold is fitted just before the power supply mains.

• Check that earthing is carried out correctly: connect all metal parts for closure (doors, gates etc.) and all system components provided with an earth terminal.

• Fit all the safety devices (photocells, electric edges etc.) which are needed to protect the area from any danger caused by squashing, conveying and shearing, according to and in compliance with the applicable directives and technical standards.

• Position at least one luminous signal indication device (blinker) where it can be easily seen, and fix a Warning sign to the structure.

• The Company declines all responsibility with respect to the automation safety and correct operation when other manufacturers’ components are used.

• Only use original parts for any maintenance or repair operation.

• Do not modify the automation components, unless explicitly authorised by the company.

• Instruct the product user about the control systems provided and the manual opening operation in case of emergency.

• Do not allow persons or children to remain in the automation operation area.

• Keep radio control or other control devices out of children’s reach, in order to avoid unintentional automation activation.

• The user must avoid any attempt to carry out work or repair on the automation system, and always request the assistance of qualified personnel.

• Anything which is not expressly provided for in the present instructions, is not allowed.

• Installation must be carried out using the safety devices and controls prescribed by the EN 12978 Standard.

2) GENERAL OUTLINE

This controller is suitable for residential use and has been designed for swing gates with particularly large gate posts. The drive arm, built with a special anti-shearing shape, allows the leaves to be moved when the controller is considerably out of place with respect to the fulcrum of the leaves. The non-reversible electro-mechanical gearmotor maintains the stop during closing and opening.

The release knob with personalised key, fitted outside each operator, makes manual manoeuvre extremely easy.

WARNING! The installation, the maintenance and the repair should be done by responsible and qualified persons with an updated knowledge of the current safety standards. It’s strictly forbidden to service the automation when the power is on.

ATTENTION! The IGEA model controller is not equipped with mechanical torque adjustment. It is compulsory to use a control panel of the same manufacturer, in compliance with the basic safety requirements of directives

73/23/CEE, 89/336/CEE, 89/37/CEE equipped with appropriate electric adjusment of the torque.

3) TECHNICAL SPECIFICATIONS

Voltage: ......................................................................230V

~ ±10% 50Hz (*)

Motor: .....................................................................Single-phase 1400min -1

Power: ................................................................................................. 300W

Absorption: .......................................................... 1.7A (230V); 3,4A (110V)

Capacitor: ........................................10µF 450V (230V); 40µF 250V (110V)

Insulation class: ......................................................................................... F

Thermal protection: .......................................................130°C self-resetting

Lubrication: ..................................................................... Permanent grease

Reduction ratio: ................................................................................... 1/812

Output revs.: ........................................................................... 1.7 min -1 max

Opening time 90°: ...................................................................................15s

Torque provided: ...............................................................320Nm (~32kgm)

Max. leaf weight and length: ...............2000N (~200kg) for 2.5m leaf length

2500N (~250kg) for 2m leaf length

Impact reaction: ......................................Electric clutch (with control panel)

Drive: ........................................................................................... Lever arm

Stopping:.........................................................Built-in electric limit-switches

Manual manoeuvre: ...........................Release knob with personalised key.

Number of manoeuvres: ................................................................. 100/24h

Working temperature: ......................................................... -15 C° ÷ +60 C°

Protection:............................................................................................ IP 44

Controller weight: ....................................................................160N (~16kg)

Dimensions: ................................................................................... See fig.1

* Special supply voltages on request.

In case the motor tours in the opposite side, you should invert the running buckle “M” of the operator. Refer to the relevant instruction manual for connection of the control panel.

4) OPERATOR INSTALLATION

WARNING! Refer to Fig.A for CORRECT installation.

4.1) Preliminary checks

Check that:

• The gate structure is sufficiently sturdy and rigid.

The fixing position must be worked out according to the leaf structure.

In any case, the manoeuvring arm must push against a reinforced leaf point (fig. 2).

• The leaves can be moved manually along their entire stroke.

If the gate has not been installed recently, check the wear condition of all its components. Repair or replace defective and worn parts.

Operator reliability and safety are directly affected by the condition of the gate structure.

4.2) Fitting of the manual release knob

• With reference to fig. 9, position release knob “A” on flange “B” prefitted on the cover.

• Insert adapting ring “C” in the bush with release tooth “D”.

WARNING: Depending on the operator installation position (right or left side), insert ring “C” and position bush “D” as shown in fig. 9.

• Insert space washer “E” and then shimming thrust bearing “F” into bush

”D” on the release tooth side.

• Secure everything, using appropriate self-tapping screw “G” inside the operator cover, checking the correct positioning of ring “C” and bush “D”.

• Close the operator cover, using the appropriate screws supplied.

WARNING: The release tooth on bush “D” must be inserted in the release lever as shown in fig. 9b. Otherwise, the emergency manoeuvre cannot be carried out.

Insertion is made easy by turning knob “A” to the side opposite to that for manual release (clockwise in the case of a left-hand leaf, anticlockwise in the case of a right-hand leaf) and locking it in such position by means of the appropriate key.

Check that bush “D” is placed horizontally (fig. 9b) and close the cover by positioning its front side (the one with the release knob) as indicated in fig. 9c.

• Before connecting the operator to the power supply, manually check that the release knob operates correctly.

5) FIXING OF SUPPORTING PLATE (Fig.2)

The controller is supplied complete with anchoring bracket and lever arm.

Once the reinforcement point of the leaf has been identified with the gate closed, draw an imaginary horizontal line from the centre of the reinforcement point to the gate post (fig.2). Position the anchoring bracket according to the values given in fig. 2 for openings of up to 90° or in fig.3 for openings greater than 90° up to a maximum of 125°.

IGEA Ver. 07 -

11

ENGLISH INSTALLATION MANUAL

The bracket fixing position must be flat and parallel to the leaf. Use screws or expansion bolts which are suited to the type of gate post. If the surface of the gate post is not regular, use expansion bolts with studs so that the parallel plate of the leaf can be adjusted (fig.4).

• Fasten the gearmotor to the gate post using the 4 screws, pointing the gearmotor to the left or the right (fig.5).

• Assemble the lever arm as shown in fig.6.

DX= assembly on the right leaf

SX= assemby on the left leaf

Choose the most suitable position of ‘F’ bracket for the fastening to the leaf.

• Insert the square of the first lever in the output shaft of the gearmotor and fasten it (fig.7).

• Release the operator by turning the release knob to allow easy movement of the arm (see paragraph on “EMERGENCY MANOEUVRE”).

• The correct position for the controller arm is shown in fig.8.

The leaf fixing point can be identified by positioning the arm so that it is in accordance with the distance shown in fig.8.

• Fix the angular towing bar “F” to the leaf by welding or using screws.

• With the controller released, check the correct movement of the arm.

• Repeat the same operation for the other leaf, if installed.

6) ELECTRICAL INSTALLATION SET-UP

Arrange the electrical installation as shown in fig.10.

The power supply connections must be kept separate from the auxiliary connections (photocells, sensitive edge, etc.). Fig.10 shows the cross-section and the number of connections.

WARNING! For connection to the mains, use a multipolar cable with a minimum of 4x1.5mm

2 cross section and complying with the previously mentioned regulations. For example, if the cable is out side (in the open), it has to be at least equal to H07RN-F, but if it is on the inside

(or outside but placed in a plastic cable cannel) it has to be or at least egual to H05VV-F with section 4x1.5mm

2 .

In fig.11 you will find the junction-box of the operator and the position of the cable holder which should be fixed with an adequate tightening of the bolt.

In case the motor tours in the opposite side, you should invert the running buckle “M” of the operator. Refer to the relevant instruction manual for connection of the control panel. Inside the operator the cable must be kept far from those parts which can be hot.

7) LIMIT-SWITCH SETTING

• Position the limit-switch reference cams “R-FC1” and “R-FC2” as shown in fig. 12, without tightening the fixing screws.

• Identify the opening and closing limit switches (FC1 and FC2) keeping in mind that:

In the left-hand operator (fig. 13):

FC1 corresponds to the OPENING limit switch

FC2 corresponds to the CLOSING limit switch

In the right-hand operator (fig. 14):

FC1 corresponds to the CLOSING limit switch

FC2 corresponds to the OPENING limit switch

• When the gate is fully closed or opened, rotate the corresponding cam until you perceive the click of the limit microswitch concerned, and lock it in position by tightening the appropriate screws as shown in fig. 12.

• Check that the limit switches intervene correctly, initiating a few complete motor-driven opening and closing cycles.

• Fit the cover on the operator.

• f the control panel is provided with operation-time setting, this must be set to a value slightly greater than that needed for limit-switch intervention.

• Control the operator through the control board Libra.

8) ADJUSTMENT OF LEAF PHASE DISPLACEMENT

In case of gates with two leaves, the control panel should include a delay setting function on closing of the second leaf to guarantee a correct closing manoeuvre. For the wiring of the motor which should close with a slight delay, refer to the instructions for the control panel installed.

9) MOTOR TORQUE ADJUSTMENT

WARNING: Check that the impact force value measured at the points established by the EN 12445 standard is lower than that specified in the EN 12453 standard.

The adjustment of the motor torque (anti-squashing) is performed on the control panel. See control unit instruction manual.

The adjustment should be set for the minimum force required to carry out the opening and closing strokes completely observing, however, the limits of the relevant standards in force.

CAUTION! Excessive torque adjustment may jeopardise the anti-squash safety function. On the other hand insufficient torque adjustment may not guarantee correct opening or closing strokes.

10) EMERGENCY MANOEUVRE (Fig. 15)

In the case of power failure or operation malfunctions, manual emergency manoeuvre can be carried out by turning the external release knob with personalised key.

First turn the key clockwise, then rotate the release knob to free the gate.

The knob is to be rotated anticlockwise in the case of a left-hand leaf, clockwise in the case of a right-hand leaf.

Keep the knob in its release position by turning the key further. Push the leaf slowly to open or close the gate.

To reactivate motor-driven operation, free the knob from its release position and bring it back to its initial position for normal operation.

11) AUTOMATION CHECK

Before allowing the automation to be used normally, carry out the following procedure very carefully:

• Check the correct functioning of all safety devices (limit microswitches, photocells, sensitive edges etc.).

• Check that the thrust (anti-squash) force of the leaf is within the limits set by current regulations.

• Check the manual opening command.

• Check the opening and closing operations with the control devices in use.

• Check the standard and customised electronic functioning logic.

12) AUTOMATION OPERATION

Since the automation can be remote-controlled by means of a remote control device or a start button, and so out of sight, the good working order of all the safety devices should be checked regularly. In the event of any anomalous functioning of the safety devices, consult a specialised technician immediately. Keep children at a safe distance from the automation operation area.

13) CONTROL

The automation is used for the power-operated opening and closing of the gate. The control can be of a number of types (manual, remote-controlled, magnetic badge access control, etc.) depending on requirements and the characteristics of the installation. See the specific instructions for the various control systems. Users of the automation must be instructed about its control and operation.

14) MAINTENANCE

Disconnect the power supply when carrying out any maintenance operations.

• Lubricate the IGEAs of the manoeuvring arm regularly.

• Clean the lenses of the photocells every so often.

• Have a specialised technician (installer) check the adjustment of the electric clutch.

• In the event of any anomalous functioning which cannot be resolved, disconnect the power supply and contact a specialised technician (installer). Whilst the automation is out of order, activate the manual release to allow manual opening and closing.

15) SCRAPPING

WARNING! This operation should only be carried out by qualified personnel.

Materials must be disposed of in conformity with the current regulations.

In case of scrapping, the automation devices do not entail any particular risks or danger. In case of materials to be recycled, these should be sorted out by type (electrical components, copper, aluminium, plastic etc.).

16) DISMANTLING

WARNING! This operation should only be carried out by qualified personnel.

When the automation system is disassembled to be reassembled on another site, proceed as follows:

• Disconnect the power supply and the entire external electrical installation.

• In the case where some of the components cannot be removed or are damaged, they must be replaced.

WARNINGS

Correct controller operation is only ensured when the data contained in the present manual are observed. The company is not to be held responsible for any damage resulting from failure to observe the

installation standards and the instructions contained in the present manual.

The descriptions and illustrations contained in the present manual are not binding. The Company reserves the right to make any alterations deemed appropriate for the technical, manufacturing and commercial improvement of the product, while leaving the essential product features unchanged, at any time and without undertaking to update the present publication.

12 -

IGEA Ver. 07

CORRETTO / RIGHT / JUSTE / RICHTIG / CORRECTO / JUSTO:

Fig. A

NON CORRETTO / WRONG / FAUX / FALSCH / NO CORRECTO / ERRADO:

360

Fig. 1

93˚

220

146

110

600

Fig. 2

170 20

170

Fig. 3

110

700

170

Fig. 4

180˚

Fig. 5

Fig. 6

S

F

S

Destra/Right/Dr oite / Rec hts / Derec ha / Direita do / Esquer da he / Linke / Izquier

S

Sinistra / Left / Gauc

S

Sinistra / Left

Gauche / Linke

Izquierdo / Esquerda

Destra / Right

Droite / Rechts

Derecha / Direita

Fig. 7

Fig. 8

1015

IGEA Ver. 07 -

21

Fig. 9

Fig. 9b

D

C

B

A

G

F

E

D

C

LEFT

D

C

LEFT

1

RIGHT

2

D

C

RIGHT

Fig. 9c

3

D

LEFT D

RIGHT

D

Fig. 10

22 -

IGEA Ver. 07

CF

2

T

M

Fre

2

4x1m m

S

AL

Fri

CF

2

4x1mm

4x1.5m

2 m

Fte

3x1mm

2

RG58

2x1.5mm

2

2x1.5mm

2

QR

M

I

3x1.5m

m 2

F1

F2

1 2

3

PG11

GND

L

230V

N

Fig. 11

F2-NC

F1-NC

F2-COM

F1-COM

M

CM

M

1

2

3

F1

F2

NERO-BLACK-NOIR-SCHWARZ-NEGRO-PRETO

MARRONE-BROWN-MARRON-BRAUN-MARON-CASTANHO

CELESTE-SKY-BLUE-BLEU CLAIR-HELLBLAU-AZUL-CELESTE

M

Fig. 12

R - FC2

R - FC1

R - FC1

R - FC2

FC1

FC2

FC1

FC2

FC1

FC2

LEFT

Fig. 13

SX (LEFT)

OPEN SX FC1

DX (RIGHT)

Fig. 14

CLOSE DX FC1

CLOSE SX FC2

OPEN DX FC2

RIGHT

IGEA Ver. 07 -

23

Fig. 15

2

3

D

LEFT

1

Fig. 16

3

2

1

RIGHT

ø 5 mm

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement