Audac
IP Link® Device Interface
Communication Sheet
adac_25_5765_1.pke
Revision: 4/19/2012
This document provides additional assistance with wiring your Extron IP Link enabled product to your device.
Different components may require a different wiring scheme than those listed below.
For complete operating instructions, refer to the user's manual for the specific Extron IP Link enabled product or
the controlled device manufacturer supplied documentation.
Device Specifications:
Device Type:
Manufacturer:
Firmware Version:
Model(s):
Audio Processor
Audac
N/A
M1
Version History:
Driver
Version
1
Date
4/12/2012
IP Link
Compiler
GC
Version
1.5.1
3.3.1
Notes
Initial version.
Driver Notes:
Page 1 of 3
IP Link® Device Interface
Communication Sheet
adac_25_5765_1.pke
Control Commands & States:
Input Ch.1 – 7
0 to 62 in steps of 1
Mute All Channels
On
Off
Mute Input 1 – 7
On
Off
Mute Output 1 – 4
On
Off
Output Ch.1 – 4
0 to 62 in steps of 1
Recall
Execute
Save
Execute
Zone 1 – 4
1–7
Zone 1 – 4 Take
Tie
Break
Connection Status
Connected
Disconnected
Input Ch.1 – 7
0 to 62 in steps of 1
Mute Input 1 – 7
On
Off
Mute Output 1 – 4
On
Off
Status Available:
MLC60 Series Supported Commands:
Mute All Channels
On
Off
Mute Input 1 – 7
On
Off
Mute Output 1 – 4
On
Off
Page 2 of 3
Revision: 4/19/2012
adac_25_5765_1.pke
IP Link® Device Interface
Communication Sheet
Cable and Adapter Requirements:
F / F RS232 Straight Serial Cable
Notes for the Device:
Make sure line 4 (DTR) is not connected.
Serial communication:
Port Type: RS-232
Baud Rate: 9600
Data Bits: 8
Parity: None
Stop Bits: 1
Flow Control: None
Pin Assignments Diagram:
Note: Captive screw connector may also be used as a serial connection.