Clayton WGX-107G-4, WGX-115G-4 Safety, Operation & Maintenance

Clayton WGX-107G-4, WGX-115G-4 Safety, Operation & Maintenance

Clayton WGX-115G-4 is a powerful air-powered HEPA industrial vacuum designed for toxic dust cleanup and general housekeeping. This model is ideal for dry recovery applications in various industries. It features a robust construction, a powerful air motor, and a HEPA filtration system for capturing even the finest particles.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Clayton WGX-115G-4 Manual - Safety, Operation & Maintenance | Manualzz
Safety – Operation – Maintenance
Keep this document in a safe place
Read and understand this manual before operating your air tool
WartHog WGX Power Head
Air Powered HEPA Industrial Vacuum
Models: WGX‑107G‑4, WGX‑115G‑4, WGX‑205G‑4, WGX‑215G‑4
• Designed for toxic dust cleanup and housekeeping
• Dry Recovery Only
Scan this QR code for
online instructions and
documentation, or visit
www.ClaytonHowTo.com
WGX-4_cover
WARNING
SAFETY LEGEND
WARNING
Read and understand operator’s manual before
using this equipment.
WARNING
Hearing protection is recommended when
operating this equipment.
WARNING
Eye protection is required when operating this
equipment.
WARNING
Respiratory protection is recommended
operating this equipment.
• A HEPA Filter must be installed in this vacuum at all times.
• If this vacuum is used to collect hazardous material, appropriate personal protective equipment may be required.
• Any alteration to this equipment by a third party will nullify its warranty.
WGX-4
August 03, 2021
TABLE OF CONTENTS
Applications & Environments................................................................................................3
What’s In the Box.................................................................................................................3
Specifications & Requirements............................................................................................3
Getting Started.....................................................................................................................4
Compressed Air Fittings.......................................................................................................5
Before Each Use..................................................................................................................5
Bag Filter Change................................................................................................................6
Safe Filter Change...............................................................................................................7
Pre‑Filter Change.................................................................................................................8
HEPA Filter Change..............................................................................................................9
Illustrated Parts Breakdown...............................................................................................10
Limited Lifetime Warranty Terms And Conditions...............................................................14
EC Declaration of Conformity.............................................................................................15
Repair or Warranty Contact
WGX-4
Page 2
Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084
www.DustlessMadeSimple.com • [email protected]
APPLICATIONS & ENVIRONMENTS
• Designed for toxic dust cleanup and housekeeping.
• Dry recovery only.
Do not use this equipment for cleaning or extracting fuel residues from any vehicle or equipment.
Do not use this equipment for cleaning or extracting live sparks or burning embers.
Do not use this equipment in combustible dust or gas atmospheres.
WHAT’S IN THE BOX
WGX-4_001
WartHog WGX Power Head
NOTE:
Clayton vacuum tanks ship in their own box and include bags, filters, and other components. These instructions assume you have
both a power head and an appropriate Clayton vacuum tank. Refer to the instruction manual included with the vacuum tank for
additional information.
SPECIFICATIONS & REQUIREMENTS
PHYSICAL:
Weight.....................................................................................................................................................................................TBD lbs (TBD kg)
Dimensions (Diameter x Height)........................................................................................................................... 17.5 x 12 in (44.5 x 30.5 cm)
Sound Level............................................................................................................................................................................................ 67 dBA
POWER CONSUMPTION:
Pressure....................................................................................................................................................................................90 psi (621 kPa)
Flow.................................................................................................................................................................................. 60 CFM (102 SCMH)
FILTRATION:
HEPA Filter Efficiency................................................................................................................................................99.995% @ 0.3 μm (H14)
Filter Bag Efficiency.............................................................................................................................................................. 95% @ 0.5 micron
PERFORMANCE:
Poly Tank
Vacuum Flow........................................................................................................................................................... 105 CFM (179 SCMH)
Vacuum Suction...........................................................................................................................................................180 inH2O (45 kPa)
Steel Tank
Vacuum Flow........................................................................................................................................................... 120 CFM (204 SCMH)
Vacuum Suction...........................................................................................................................................................120 inH2O (30 kPa)
Repair or Warranty Contact
WGX-4
Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084
www.DustlessMadeSimple.com • [email protected]
Page 3
GETTING STARTED
1. The vacuum power head and the vacuum tank ship in separate boxes.
2. Unbox the vacuum power head.
3. Visually inspect the power head to verify that no parts are missing or damaged.
4. Familiarize yourself with the power head.
Pressure Gauge
Compressed Air
Control Valve
Compressed Air
Plug (Air In)
WGX-4_002
HEPA Wire Lock
Hex Standoff
HEPA Wire Lock
Hex Standoff
Filter Adapter
Prepare the vacuum for use.
1. Install a filter bag on the tank.
• Unfold and fluff a new filter bag.
• Push the inlet tube into the hole on the cardboard collar of the filter bag.
• Grasp the sides of the cardboard collar and push it all the way onto the inlet tube.
• Verify the bottom of the collar is past the opening on the underside of the inlet tube.
Tank Wall
Filter Bag
Bottom and top of
Cardboard Bag Collar
must be flush to tank
Tank Wall
GL_005
Push Cardboard Bag Collar
past this point
2. Unbox a new HEPA filter.
• Remove the Clayton HEPA timer card from the box and set aside.
• Remove the HEPA cable lock from the box and set aside.
• Remove the HEPA filter from the box and remove from plastic bag.
continued on next page
Repair or Warranty Contact
WGX-4
Page 4
Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084
www.DustlessMadeSimple.com • [email protected]
GETTING STARTED
3. Install a new HEPA filter.
• Holding the power head on its side, screw the new HEPA filter onto the filter adapter.
• Verify the white inner ring of the HEPA filter is fully seated against the underside of the power head.
– If it is not, rotate it clockwise until it is seated.
• Refer to the instructions included with the HEPA cable lock to install the cable lock.
4. Attach the power head.
• Position the power head on the tank.
• Rotate the power head so that the compressed air control valve on the power
head is aligned with the inlet port on the vacuum tank.
• Latch the power head to the tank.
5. Activate the HEPA filter timer.
• Attach the new HEPA timer card with a zip tie (included) to the top handle of the
vacuum.
• Follow the directions on timer card to activate it.
Compressed Air
Control Valve …
WGX-4_003
aligned with …
Inlet Port
COMPRESSED AIR FITTINGS
The vacuum has the following compressed air requirements to function properly:
• Compressed air must be clean, dry, and oil free to prevent blockage of the pneumatic system.
• Compressed air line and fittings must have a minimum diameter of 1/2 in (13 mm).
Compressed Air Plug (Air In)
• The vacuum is supplied with a 1/2 in (13 mm) industrial interchange compressed air plug for connection to a compressed air supply.
The Compressed Air Plug may be changed to another nominal 1/2 in (13 mm) style if required.
• Hold the brass bulkhead fitting with a 11/4 in (32 mm) open end wrench.
• Remove the compressed air plug with either a 7/8 in (22 mm) deep socket or open end wrench.
• Install a new compressed air plug.
BEFORE EACH USE
1. Attach the vacuum hose.
• Open the inlet port on the vacuum tank.
• Insert the metal sleeve of the vacuum hose into the inlet port on the vacuum tank.
2. Activate the vacuum.
• Rotate the Compressed Air Control valve to the ON position.
Repair or Warranty Contact
WGX-4
Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084
www.DustlessMadeSimple.com • [email protected]
Page 5
BAG FILTER CHANGE
If this vacuum is used to collect hazardous material, appropriate personal protective equipment may be required.
The bag filter should be replaced when ¾ full.
1. Safe the vacuum.
• Disconnect the vacuum from compressed air source.
• Remove all hoses from the vacuum.
2. Remove the power head.
• Unlatch the power head from the tank.
• Lift the power head and the attached HEPA filter off the tank using the top handle.
• Carefully place the power head on the floor – avoid damaging the HEPA filter.
3. Remove the filter bag.
• Grasp the cardboard collar of the bag filter and slide it off the inlet port on the vacuum tank.
• Holding your hand over the opening on the bag, lift the bag out of the tank.
• Dispose of the bag according to company policy.
4. Install a new filter bag.
• Unfold and fluff a new filter bag.
• Push the inlet tube into the hole on the cardboard collar of the filter bag.
• Grasp the sides of the cardboard collar and push it all the way onto the inlet tube.
• Verify the bottom of the collar is past the opening on the underside of the inlet tube.
Tank Wall
Filter Bag
Bottom and top of
cardboard bag collar
must be flush to tank
Tank Wall
GL_005
Push cardboard bag
collar past this point
5. Verify the HEPA filter is sealed.
• Holding the power head on its side, examine the HEPA filter.
• Verify the white inner ring of the HEPA filter is fully seated against the underside of the power head.
– If it is not, rotate it clockwise until it is seated.
6. Replace the power head.
• Position the power head on the tank.
• Rotate the power head so that the Compressed Air Control valve on the power head is aligned with the inlet port on the vacuum tank.
• Latch the power head to the tank.
Repair or Warranty Contact
WGX-4
Page 6
Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084
www.DustlessMadeSimple.com • [email protected]
SAFE FILTER CHANGE
Principle of Operation
Safe Filter Change (SFC) uses a second Clayton HEPA vacuum and a Safe Filter Change Hose to create a downdraft within the primary
vacuum while changing the bag filter.
If this vacuum is used to collect hazardous material, appropriate personal protective equipment may be required.
The bag filter should be replaced when ¾ full.
1. Connect the vacuums.
• Verify the Compressed Air Control valve on both vacuums is in the AUTO/OFF position.
• Remove all vacuum hoses from the primary vacuum.
• Position the support vacuum with its inlet port facing the SFC port on the primary vacuum.
• Open the inlet port on the support vacuum.
• Insert one metal sleeve of the SFC hose into the inlet port on the support vacuum.
• Open the SFC port on the primary vacuum.
• Insert the other metal sleeve of the SFC hose into the SFC port on the primary vacuum.
• Connect both vacuums to a compressed air source.
2. Remove the power head.
• Unlatch the primary vacuum’s power head from the tank.
• Slowly lift the primary vacuum power head and attached HEPA filter approximately 1 inch off the tank using the top handle.
• Rotate the support vacuum Compressed Air Control valve to the ON position to create the downdraft.
• Rotate the primary vacuum Compressed Air Control valve to the ON position to prevent any debris from falling off the HEPA filter.
• Carefully lift the primary vacuum power head and attached HEPA filter off the tank using the top handle.
• Carefully place the power head on the floor – avoid damaging the HEPA filter. The primary power head should remain running.
3. Remove the bag filter.
• Turn a large disposal bag inside out around your arms.
• Using the disposal bag like a large mitten, grasp the cardboard collar of the bag filter and slide it off the inlet port.
• The disposal bag should remain between the user and the bag filter.
• Gently lift the bag filter while drawing the disposal bag down and around the bag filter.
• Gather the neck of the disposal bag and seal the bag closed using tape or ties.
• Dispose of the bag filter according to company policy.
4. Install a new bag filter.
• Unfold and fluff a new bag filter.
• Push the inlet tube into the hole on the cardboard collar of the bag filter.
• Grasp the sides of the cardboard collar and push it all the way onto the inlet tube.
• Verify the bottom of the collar is past the opening on the underside of the inlet tube.
Tank Wall
Filter Bag
Bottom and top of
Cardboard Bag Collar
must be flush to tank
Tank Wall
GL_005
Push Cardboard Bag Collar
past this point
continued on next page
Repair or Warranty Contact
WGX-4
Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084
www.DustlessMadeSimple.com • [email protected]
Page 7
SAFE FILTER CHANGE
5. Verify the HEPA filter is seated.
• Holding the power head on its side, examine the HEPA filter.
• Verify the white inner ring of the HEPA filter is fully seated against the underside of the power head.
– If it is not, rotate it clockwise until it is seated.
6. Replace the primary power head.
• Carefully position the primary power head on the primary tank.
• Rotate the primary vacuum Compressed Air Control valve to the OFF position.
• Rotate the power head so that the Compressed Air Control valve on the power head is aligned with the inlet port on the vacuum tank.
• Latch the power head to the tank.
• Rotate the support vacuum Compressed Air Control valve to the OFF position.
7. Disconnect the vacuums.
• Disconnect the SFC hose from the primary vacuum SFC port.
• Disconnect the SFC hose from the support vacuum inlet port.
PRE‑FILTER CHANGE
If this vacuum is used to collect hazardous material, appropriate personal protective equipment may be required.
Replace the pre‑filter every five (5) bag filter changes or when it becomes visibly dirty.
1. Safe the vacuum.
• Disconnect the vacuum from the compressed air source.
• Remove all hoses from the vacuum.
2. Remove the power head.
• Unlatch the power head from the tank.
• Lift the power head and the attached HEPA filter off the tank using the top handle.
• Carefully place the power head on the floor – avoid damaging the HEPA filter.
3. Remove the pre‑filter.
• The pre‑filter is wrapped around the HEPA filter and secured with Velcro.
• Find the seam and carefully peel the Velcro apart.
• Dispose of the pre‑filter according to company policy.
4. Install a new pre‑filter.
• Unfold a new pre‑filter and remove the thin Velcro cover strip from the Velcro hooks.
• Wrap the pre‑filter tightly around the HEPA filter.
• Secure the pre‑filter by adhering the Velcro hooks to the side of the pre‑filter.
5. Verify the HEPA filter is seated.
• Holding the power head on its side, examine the HEPA filter.
• Verify the white inner ring of the HEPA filter is fully seated against the underside of the power head.
– If it is not, rotate it clockwise until it is fully seated.
6. Replace the power head.
• Position the power head on the vacuum tank.
• Rotate the power head so that the Compressed Air Control valve on the power head is aligned with the inlet port on the vacuum tank.
• Latch the power head to the tank.
Repair or Warranty Contact
WGX-4
Page 8
Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084
www.DustlessMadeSimple.com • [email protected]
HEPA FILTER CHANGE
If this vacuum is used to collect hazardous material, appropriate personal protective equipment may be required.
The HEPA filter should be replaced when it is damaged, clogged, or when the HEPA timer card has reached 12 months. Never attempt to clean
the HEPA filter as this will damage it.
1. Safe the vacuum.
• Disconnect the vacuum from the compressed air source.
• Remove all hoses from the vacuum.
2. Remove the power head.
• Unlatch the power head from the vacuum tank.
• Lift the power head and the attached HEPA filter off the tank using the top handle.
• Carefully place the power head on the floor – avoid damaging the HEPA filter.
3. Unbox a new HEPA filter.
• Remove the Clayton HEPA timer card from the box and set aside.
• Remove the HEPA cable lock from the box and set aside.
• Remove the HEPA filter from the box and remove it from the plastic bag.
4. Remove the old HEPA filter.
• Holding the power head on its side cut the HEPA cable lock and remove it.
• Unscrew the HEPA filter from the filter adapter.
• Dispose of the HEPA filter according to company policy.
5. Install a new HEPA Filter.
• Holding the power head on its side, screw the new HEPA filter onto the threaded filter adapter.
• Verify the white inner ring of the HEPA filter is fully seated against the underside of the power head.
– If it is not, rotate it clockwise until it is fully seated.
• Refer to the instructions included with the HEPA cable lock to install the cable lock.
6. Replace the power head.
• Carefully position the power head on the vacuum tank.
• Rotate the power head so that the Compressed Air Control valve on the power head is aligned with the inlet port on the vacuum tank.
• Latch the power head to the vacuum tank.
7. Activate the HEPA filter timer.
• Remove the old HEPA timer card from the power head.
• Attach the new HEPA timer card with a zip tie (included) to the top handle of the vacuum.
• Follow the directions on the timer card to activate.
Repair or Warranty Contact
WGX-4
Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084
www.DustlessMadeSimple.com • [email protected]
Page 9
Illustrated
Parts Breakdown
Illustrated
Parts
Breakdown
603-WGX-4 (Sheet 1 of 4)
Seq
1
2
3
4
5
6
7
8
9
10
11
12
Item No
605-310A
605-316E
918-08BH
924-0502
925-P24R160-01
930-027
940-08PM
FE103212-HZSM-Z
NE10320608-HNSZ
RE0620-SDSSS-Z
SE103206-XPSM-Z
WE133203-RFS-Z
Description
HH Vac Head Handle Cap SS Black
WTX Vac Enclosure Toxic Pneu SS Black
Bulkhead, 1/2 X 1/2, Brass
Valve, 1/2, MPT X FPT, Ball Valve
Gauge Pressure 1.5in 0-160 psi Panel Mount
Handle, Carry, Flex Rubber
FTG, Plug, 1/2 in MNPT
Hex Standoff, 10-32 MF X 3/4 in SS
Nut 10-32 Nylon Lock SS Short
Rivet Blind 3/16 X 0.625 Sealed SS (.251-.375)
Screw 10-32 X 3/8in SS TORX
Washer .203ID X .500OD .047H Round Stainless Steel
6
12
10
11
1
8
4
7
3
2
9
5
WGX-4_004
Repair or Warranty Contact
WGX-4
Page 10
Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084
www.DustlessMadeSimple.com • [email protected]
Illustrated Parts Breakdown
603-WGX-4 (Sheet 2 of 4)
Seq
1
2
3
4
5
6
Item No
922-T.25GN
922-T.50NGE
927-04L-02F
927-08L-08
927-08R04
927-08T-08
Description
1/4 in OD. Nylon Tubing Green
Tubing, 1/2 Polyethylene, Orange
FTG Elbow 1/8 FNPT To 1/4 PC
FTG Elbow 1/2 PC To 1/2 MNPT
FTG Reducer 1/2 MPC To 1/4 PC
FTG Tee 1/2 PC To 1/2 MPT
2
6
5
4
3
1
WGX-4_005
Repair or Warranty Contact
WGX-4
Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084
www.DustlessMadeSimple.com • [email protected]
Page 11
Illustrated
Parts Breakdown
Illustrated
Parts
Breakdown
603-WGX-4 (Sheet 3 of 4)
Seq
1
2
3
4
4
4
Item No
911-803-1
911-803-3
911-803-4
911-803-6
911-803-7
911-803-8
Description
Handle Cap Sound Control Foam
Enclosure Top Sound Control Foam
Base Ring Sound Control Foam
Enclosure Foam 1 Sound Control
Enclosure Foam 2 Sound Control
Enclosure Foam 3 Sound Control
1
4
2
3
WGX-4_006
Repair or Warranty Contact
WGX-4
Page 12
Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084
www.DustlessMadeSimple.com • [email protected]
Illustrated Parts Breakdown
603-WGX-4 (Sheet 4 of 4)
Seq
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Item No
600-019
600-WF-1364F
601-021
602-812
605-310B16
911-011
911-812
FE103208-HZSM-B
FE103224-HZSM-Z
NE10320615-HNSZ
SE103206-XPSM-Z
SE103210-ACSM-L
SE162012-XPSM-Z
WE133203-RFS-Z
Description
Air Motor WartHog
Washer Fiber 13/64 ID X 3/8OD
Filter Adapter, WartHog
Can Plastic Muffler Black
HH Vac Head Base 16in SS Black
Gasket, Filter Adapter
Muffler Felt Kit For WartHog Air
Hex Standoff, 10-32 MF X 1/2 SS With Bore
Hex Standoff SS, 10-32 M-F X 1.5in Long
Nut, 10-32 Nylon Lock, SS, High
Screw 10-32 X 3/8in SS TORX
Screw 10-32 X 5/8 Low Socket Cap SS
Screw 1/4-20 X 3/4in Button Head Torx SS
Washer .203ID X .500OD .047H Round Stainless Steel
11
14
7
7
4
9
1
7
5
10
WGX-4_007
6
2
3
8
12
Repair or Warranty Contact
WGX-4
13
Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084
www.DustlessMadeSimple.com • [email protected]
Page 13
LIMITED LIFETIME WARRANTY TERMS AND CONDITIONS
Warranty Terms
Clayton Associates, Inc. guarantees its manufactured products against defects in materials or workmanship and will either repair or replace
all parts that prove defective under normal use during the lifetime of the products. The warranty period shall commence from the date of paid
invoice.
This warranty does not cover (a) repairs due to normal wear, accident, neglect, misuse, or use other than as indicated in the instruction booklet
(b) products manufactured by third parties and distributed by Clayton (c) wear items such as bearings, rotor blades, regulators, valve stems,
levers, shrouds, guards, O-rings, seals, gaskets, motor brushes, and other wearable parts.
Repair within the Continental US
During the first 90 days of the warranty period, Clayton will provide parts and labor to the customer’s site at no charge or pay freight costs
associated with returning the products for repair to a Clayton selected service location and repair the product at no charge. Clayton personnel
will determine the best way to repair the product.
Past 90 days, Clayton will provide parts to the customer’s site at no charge or the customer may ship the product to a Clayton selected service
location at customer’s expense and Clayton will repair the product at no charge and provide return shipping.
Repair Outside the Continental US
Clayton will provide parts to the customer’s site at no charge or the customer may ship the product to a Clayton selected service location at
customer’s expense and Clayton will repair the product at no charge and provide return shipping.
Limitation of Liability
Clayton shall not in any event be liable for any damages, loss of production time or profits, whether based on contract, warranty, negligence,
strict liability or otherwise, including without limitation any consequential, incidental or special damages, arising with respect to the equipment
or its failure to operate.
Clayton Associates, Inc. makes no other warranty or representation of any kind, except that of title, and all other warranties, express or implied,
including warranties of merchantability or fitness for any particular purpose, are hereby expressly disclaimed.
Repair or Warranty Contact
WGX-4
Page 14
Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084
www.DustlessMadeSimple.com • [email protected]
EC Declaration of Conformity
Clayton Associates, Inc. of 1650 Oak Street, Lakewood New Jersey 08701 U.S.A. declare on our own responsibility that the
following equipment:
Industrial HEPA Filtered, Electrically Powered Vacuum Cleaners and Accessories for Dry Recovery
• Vacuum Models (where XXXX is the Tank Model):
WGX-XXXX-0, WGP-XXXX-0, WTX-XXXX-0, WTP-XXXX-0
WGX-XXXX-1, WGP-XXXX-1, WTX-XXXX-1, WTP-XXXX-1
• Tank Models: 115G,115T,205G, 205T, 215G, 215T
• With serial numbers ranging from WH0000001 through WH9999999
Are designed and manufactured in compliance with the essential requirements and other relevant provisions of the following
applicable directives:
• Machinery Directive 2006/42/EC
• The Electromagnetic Compatibility Directive 2004/108/EC
Compliance has been obtained by application of the following standards:
• EN ISO 12100:2010-11
• EN 60335-1:2012/A13 excluding 25.6
• EN 60335-2-69:2012 specifically Annex AA: Requirements for vacuum cleaners and dust extractors for the
collection of hazardous dusts
• EN 55014-1:2017
• EN 55014-2:2015
The legally authorized entity, established in the EU for compiling the technical file is ExVeritas Limited, Unit 16-18, Abenbury
Way, Wrexham Industrial Estate, Wrexham, LL13 9UZ, United Kingdom.
File Number: 18FILE0423
Subject to use for the purpose for which it was designed in accordance with relevant standards and with the manufacturer’s
recommendations. We hereby declare that the equipment specified above conforms to the listed Directives and Standards.
Brad Clayton
President
Clayton Associates, Inc.
Place of Issue: Lakewood, New Jersey, USA November 23, 2018
Repair or Warranty Contact
WGX-4
Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084
www.DustlessMadeSimple.com • [email protected]
Page 15
EC Declaration of Conformity
Clayton Associates, Inc. of 1650 Oak Street, Lakewood New Jersey 08701 U.S.A. declare on our own responsibility that the
following equipment:
Industrial HEPA Filtered, Electrically Powered Vacuum Cleaners
• Vacuum Models (where XXXX is the Tank Model):
WGX-XXXX-0, WGP-XXXX-0, WTX-XXXX-0, WTP-XXXX-0
WGX-XXXX-1, WGP-XXXX-1, WTX-XXXX-1, WTP-XXXX-1
• Tank Models: 115G,115T,205G, 205T, 215G, 215T
• With serial numbers ranging from WH0000001 through WH9999999
Were tested to verify the integrity of the HEPA filter and the assembled machine.
Test Procedure:
• The test was performed using an aerosol generator and a photometer.
• The system was challenged with 18 microliters/mᶟ Poly Alfa Olefin (PAO).
• The system was fitted with a HEPA filter, part number 627-12H having a certified minimum efficiency of 99.995%.
Test Results:
• The filtration efficiency of the assembled WartHog vacuum was 99.9978%
• Test performed at: 740 Driving Park Avenue, Rochester NY 14613 USA
Declaration:
• The assembled unit meets the standard for US HEPA filtration and EU H14.
Brad Clayton
President
Clayton Associates, Inc.
Place of Issue: Lakewood, New Jersey, USA November 23, 2018
Repair or Warranty Contact
WGX-4
Page 16
Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084
www.DustlessMadeSimple.com • [email protected]
THIS PAGE IS INTENTIONALLY BLANK
Clayton products are proudly made in the USA
Repair or Warranty Contact
Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084
www.DustlessMadeSimple.com • [email protected]

advertisement

Key Features

  • HEPA filtration
  • Dry recovery
  • Air-powered
  • Industrial vacuum
  • Toxic dust cleanup
  • Powerful motor
  • Durable construction

Frequently Answers and Questions

What type of dust can the Clayton WGX-115G-4 vacuum collect?
It's designed for toxic dust cleanup, meaning it can handle hazardous substances like asbestos and lead dust.
Is the Clayton WGX-115G-4 suitable for wet applications?
No, this vacuum is only for dry recovery. Refer to the manual for prohibited applications.
How often should I replace the HEPA filter on the Clayton WGX-115G-4?
Replace the HEPA filter when damaged, clogged, or after 12 months, as indicated by the HEPA timer card.
What are the compressed air requirements for the Clayton WGX-115G-4 vacuum?
It requires clean, dry, and oil-free compressed air with a minimum diameter of 1/2 in (13 mm) for proper operation.

Related manuals

Download PDF

advertisement