F3SG-R Series
C o m p a c t : E a s y i n s t a l l a t i o n
»
Robust: Even in severe environments
»
G l o b a l : R e l i a b l e s a f e t y s o l u t i o n s
2
Next generation safety
Advance
Advance type suitable for flexible production line applications
Easy
NEW
Easy type ideal for simple On/Off detection applications
Operating range
0.3 to 10.0 m
F3SG-4RA -14
Protective height
160 to
2080 mm
Detection capability: Dia. 14 mm
Protective height
190 to
2510 mm
Operating range
0.3 to 20.0 m
F3SG-4RA -30
Detection capability: Dia. 30 mm
Protective height
160 to
2080 mm
Operating range
0.3 to 10.0 m
F3SG-4RE -14
Detection capability: Dia. 14 mm
Operating range
0.3 to 20.0 m
Protective height
190 to
2510 mm
F3SG-4RE -30
Detection capability: Dia. 30 mm
light curtain packed with powerful features, offering both robustness and reliability
F3SG-R Benefit
Previously it took time to select the right safety light curtains for the conditions: physical conditions such as size and operating range, ambient environments, and countries.
If just one single safety light curtain can be used in a variety of environments, the time required for selection, installation, and maintenance can be reduced.
Selection & Design
35mm
>> p4
35mm
Thinnest part
2.5 mm
Easy Selection & Design
In almost any environment
Waterproof and shock-resistant yet compact body. Conforms to major international standards including Chinese standard GB 4585 to be used worldwide.
Ensuring safety in various production lines
The Muting function to automatically set a minimum muting zone according to workpiece height.
Can be used for a variety of production lines.
Complete safety measures by detecting presence
Distinguishes between small object passing and human entry by changing resolution and response time.
This maintains a high level of safety while minimizing unexpected machine downtime.
Set-up
Easy Set-up
Drastically reduced set-up time and wiring
The Smartclick connectors and optical synchronization enable smooth set-up of machines.
Simple, two-step optical adjustment
Quick adjustment by checking beam alignment with the LED indicators and Configuration Tool SD Manager2.
Flexible installation
More flexible layout by eliminating the need of synchronization wiring and using extension cables.
>> p8
Operation
Stable Operation
Quick troubleshooting and predictive maintenance
The sticker and error logs stored in the F3SG-R helps speed troubleshooting. Accumulated log data facilitates systematic maintenance.
Mutual interference prevention
The DIP switches is used to change emission light intensity to prevent mutual interference with other sensors.
>> p10
Microsoft product screen shot(s) reprinted with permission from Microsoft Corporation.
The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. Any use of such marks by Omron is under license.
Other company names and product names in this document are the trademarks or registered trademarks of their respective companies.
3
4
Easy Selection & Design
R o b u s t n e s s
Allows use in a variety of environments
P r o t e c t s i t s e l f a n d p r o d u c t i o n s i t e s
In almost any environment
| For global use |
35mm
Thinnest part
2.5 mm
Work piece
35mm
The housing structure is significantly improved to enhance resistance against shock and vibration and to reduce the thickness of the thinnest part of the housing material from 3 mm to
2.5mm.
The optical surface can be protected from contact with workpieces by using the optional protection cover together.
Downsized
The robust housing can be used in harsh conditions and withstand shocks caused by sudden human contact or a dropped tool. The scratch-resistant material is used for the optical surface to prevent unexpected machine stops.
F3SG-R
MS48
F3SR
Cross-section is
Approx.
60
%
of previous model
NPN
Gl o al
PNP
PNP or NPN can be selected with the
DIP switch. The same cables are used.
Several types of safety light curtains with different environmental resistance and functionality were required to suit the installation environment. It took time to select the right models.
Advance
GB
In t t rn at
St a da io da rd na l
IEC
ISO
The F3SG-R conforms to major international standards including Chinese GB standards
Advance Easy
Robust and Compact
| Robust housing | Advance Easy
All models are equipped with a robust housing that can be used in harsh conditions and withstand shocks caused by sudden human contact or a dropped tool. The scratch-resistant material is used for the optical surface to prevent unexpected machine stops.
Slim housing Protected with protection cover
Secured against torsion
5 times more
torsion resistant*
Previous model
F3SG-R
The risk of optical axis misalignment due to vibration or aging can be reduced.
* Compared to OMRON previous model in December 2014.
Reliable even in harsh environments
High power
Advance Easy
The newly designed high-power optical system provides the best-in-class* light transmission and operating range. This allows stable operation even in dusty or other environments where light transmission is reduced.
* Based on OMRON investigation in December 2014.
Operating range
20 m max.
N e w M u t i n g Fu n c t i o n a l i t y
Increases both productivity and safety
E a s i l y d i s t i n g u i s h e s b e t w e e n w o r k e r s a n d o b j e c t s
Advance
Increasing both productivity and safety
| Muting function | Advance
The F3SG-R provides advanced Muting function that detects the zone where workpieces pass or the position of a machine or robot and disable beams of the detected part. This increases both safety and productivity.
By adding the smart muting actuator, the F3SG-R provides stable operation even for the production lines where errors occur due to vibration caused by the passing workpiece.
Previously…
Vibration
September 2014)
Installation Wiring Adjustment Troubleshooting Maintenance
Opening
The point detection muting sensor mistakenly disabled muting while a workpiece was passing, which led to unexpected machine stops.
Smart muting actuator
Reduced by 80%
0 10 20 30 40 50 60 70 80 90 100
Previously…
Many processes including programming and adjustment were required
Since bypass processing to disable the safety light curtain was performed via the PLC, programming before installation required time and
Smart muting actuator
5
6
Easy Selection & Design
Auto-configuration of muting zone
| Dynamic Muting | Advance
When workpieces with various heights are conveyed on the same line, partial muting is automatically performed based on the height of the workpiece. This advanced muting function can automatically perform normal detection at the zone where a workpiece does not pass.
Automatically minimizes muting zone according to workpiece size
1
When the muting sensor detects that a workpiece passes, all beams are muted.
P o w e r f u l F e a t u r e s
Prevent unexpected machine stops
E n s u r e s t a b l e o p e r a t i o n
Minimizing setting and detection errors
| Configuration Tool SD Manager2 | Advance
2
The only beams interrupted by the workpiece are kept muted and other beams are released from the muting state three seconds after the workpiece pass through the safety light curtain. Muting is disabled after the workpiece has passed.
downtime.
Monitors human entry into the zone where a workpiece does not pass.
Keeps the zone muted when a workpiece passes.
zed data djustment smooth!
Advance
Detecting both objects and workers
| Reduced Resolution | Advance
With the Reduced Resolution function that is used to change the number of interrupted beams (1 to 3 beams), the F3SG-R can detect human entry while workability is maintained. This makes easier to distinguish between objects and workers.
Keep the safety outputs ON even when an object like a transport vehicle (with the size of 1 to 3 beams) is present discontinuously.
Turn safety outputs OFF when an object with the size over 3 beams, like an ankle,
Preventing accidental stops due to insects
| Response Time Adjustment | Advance
This function is used to distinguish between an instant passing of a small object such as an insect and a human passing by changing the time to respond to the block of the beam. Accidental machine stops can be avoided.
1
2
3
The machine cannot be restarted until the pre-reset switch is pressed to restart the F3SG-R.
1 Press the pre-reset switch in the hazardous zone (safety fence)
2 Get out of the hazardous zone
(safety fence)
3 Press the reset switch in the control panel to restart the F3SG-R.
The machine is ready for restart.
7
8
Easy Set-up
S m a r t
W i r i n g , B e a m A d j u s t m e n t ,
a n d O p e r a t i o n C h e c k
Facilitate installation
No torque control required
| Smartclick |
Advance Easy
Smartclick connectors are used to quickly connect cables. Just turn the round waterproof M12 connector 1/8 of a turn. This stress-free connection reduces time required for wiring and replacement when many devices are connected together.
Smartclick
Smartclick is a registered trademark of OMRON Corporation.
Click!
Insert fully
Rotate 1/8 turn to connect
Rotate
1/8 turn
This popular connector is used for a variety of OMRON products to reduce time required for wiring and replacement when many devices are connected together.
Previously… Faulty connection and need of torque control
When many safety light curtains were connected, torque control of connectors was required and delay in set-up occurred due to failure of connection. The Smartclick connector can be connected with the existing screw-type M12 connector.
No limitation in wiring
| Optical synchronization |
Advance Easy
Optical synchronization eliminates the need of synchronization wiring between the emitter and receiver. Flexible wiring enables reducing disconnection risk and avoiding noise sources.
Flexible, new method
Fine tuning all beams, the F3SG-R provides high ambient light immunity and flexible detection functions.
High ambient light immunity
Start-up
The Top or Bottom beam of the emitter starts synchronizing with the corresponding beam of the receiver.
After sync
Once synchronization is done, the emitter is kept synchronized with the receiver while at least one beam is unblocked.
Long-distance wiring
| Maximum 100 m cable length | Advance Easy
The total extension cable length is up to 100 m. Flexible wiring maximizes long-distance detection and optical synchronization functionality.
Simple wiring
| Simple wiring connector |
Advance Easy
Simple wiring connector can reduce wiring time. Fewer cables mean that the risk of disconnection and noise troubles can also be reduced.
Previously…
Cables of the emitter and receiver
Only one cable
Previously…
Limitations imposed by synchronization wiring
Wiring and connection works between the emitter and receiver were required.
With the previous synchronization function, if the Top or Bottom beam was blocked, synchronization was not maintained.
100 m max.
Simple two steps
| Beam adjustment |
Advance
The benefit of robust, torsion-resistant housing contributes to reduce the time required to install the safety light curtain.
Simple adjustment: Coarse adjustment positional alignment
Beam adjustment can be done easily by checking the TOP and BTM LED indicators. The SD Manager 2 helps install the safety light curtain by showing the incident light levels of each beam.
1
TOP indicator turns
ON when top end receives light.
TOP
(top-beam-state indicator)
Easy adjustment after mounting
| Mounting bracket |
Advance Easy
Two types of mounting brackets are available.
Standard fixed bracket
Standard adjustable bracket
(sold separately)
After mounted on a safety fence, the F3SG-R can be slid vertically to adjust. This means this mounting bracket allows for a wider adjustment range than the existing top/bottom mounting bracket.
In addition to vertical adjustment, the angle can be adjusted up to
±15°.adjusted up to
±15°.
2
BTM indicator turns
ON when bottom end receives light.
BTM
(bottom-beam-state indicator)
1
Adjustment is completed when the TOP, BTM, and STB LED indicators turn ON.
2
Finer adjustments can be made using the Configuration Tool SB Manager2.
Standard fixed bracket
The bracket is included in the F3SG-R.
Protective height
Less than 1,280 mm
No. of brackets included
2 sets
1,280 to 2,270 mm
2,350 mm or more
3 sets
4 sets
9
10
Stable Operation
Q u i c k
Troubleshooting and Predictive Maintenance
Eliminate machine downtime to ensure stable operation
For global operators
| Multilingual troubleshooting | Advance Easy
Troubleshooting in eight languages is published on the website to find causes and solutions of errors that occur during operation. Operators across the world can check the error details in their local languages, which will help them minimize time to troubleshoot.
Troubleshooting Web
* English, Chinese, Italian, Korean,
French, German, Spanish, and Japanese
Troubleshooting guide sticker
Reducing stops due to mutual interference
| Operating Range Selection | Advance Easy
When other sensors are installed near the F3SG-R, Operating Range
Selection helps reduce mutual interference.
Operating range
Short
7m
Mutual interference with the other sensor near the F3SG-R can be reduced by changing the mode from Long * to Short (7 m).
Long
20m
*. Maximum operating range of 20 m for hand/arm protection or 10 m for finger protection
* The Interface Unit F39-GIF is required to connect with a personal computer.
Quick troubleshooting
| Data logging 1 |
Advance
The error logs stored in the F3SG-R can be obtained by connecting with a personal computer via the interface unit. The Configuration Tool SD
Manager2 analyzes error logs to identify causes of errors and suggest solutions. This helps simplify troubleshooting.
Systematic maintenance based on trend management
| Data logging 2 | Advance
By using the Configuration Tool SD Manager2, the data of light intensity, power-ON time, and switching frequency of the F3SG-R can be collected regularly to predict when systematic and preventive maintenance is required.
The mode of Operating Range Selection can be selected with the DIP Switches* on the emitter.
*. For the F3SG-RE, the mode can be selected by wiring.
N E W Easy type
Easy-to-use safety sensor
Ideal for Simple On/Off
Detection Applications
Robust but slim housing and basic safety functions are inherited from the F3SG-R Advance type.
Providing only simple safety functions, the Easy type helps save TCO (Total Cost of Ownership) by reducing errors that required a lot of time to identify the causes.
Simple wiring
Only four wires are required for the minimum configuration, which is as simple as wiring a photoelectric sensor. Simple connection with a safety controller makes it easy to build a safety circuit. Commercially available M12 connector cables can be used for extension cables.
F3SG-R
Line-up
For flexible production lines
Fast response time of 5 ms
The Easy type that allows the distance between the light curtain and hazard source to be reduced is best suited to use in a small machine.
For small machines
List of Feature
Feature
PNP/NPN Selection
External Test
Interlock
Pre-Reset
External Device Monitoring(EDM)
Auxiliary Output
Muting
Override
Fixed Blanking
Floating Blanking
Reduced Resolution
Warning Zone
Scan Code Selection
Operating Range Selection
Response Time Adjustment
Lamp
Designated Beam Output
Cascade Connection
Setting by DIP Switch
Advance type
F3SG-RA
Setting by Configuration Tool Setting by Wiring
Safety Sensor
Line-up
More slim models
Safety Light
Curtain F3SJ
Cat. No. F074
Easy type
F3SG-RE
Factory default setting
(Advance type)
PNP output
24 V Active
Auto Reset Mode
Disabled
Disabled
Muting
/Override information
Standard Muting mode
Enabled
Disabled
Disabled
Disabled
Disabled
CodeA
Short mode
Standard mode
Red:Disabled
Orange:Disabled
Green:Muting/Override information
Disabled
For flexible
zone detection
Safety Laser
Scanner
Cat. No. Z298
Safety Light Curtain Advance type
F3SG-RA
New Standard of Safety Light
Curtain,Offering Both Robustness and Reliability
• Robust and compact
• New muting function to increase both productivity and safety
• All models designed for global use. PNP/NPN selection by
DIP switch
• Conforming to major international standards including
Chinese standard GB 4584
12
Ordering Information
Main Units
Safety Light Curtain
Finger protection
Number of beams
15
23
31
39
47
55
63
71
79
Protective height
(mm)
160
240
320
400
480
87 880
95 960
103 1,040
111
119
1,120
1,200
560
640
720
800
127
135
143
151
159
167
175
1,280
1,360
1,440
1,520
1,600
1,680
1,760
183 1,840
191 1,920
Model
F3SG-4RA0160-14
F3SG-4RA0240-14
F3SG-4RA0320-14
F3SG-4RA0400-14
F3SG-4RA0480-14
F3SG-4RA0560-14
F3SG-4RA0640-14
F3SG-4RA0720-14
F3SG-4RA0800-14
F3SG-4RA0880-14
F3SG-4RA0960-14
F3SG-4RA1040-14
F3SG-4RA1120-14
F3SG-4RA1200-14
F3SG-4RA1280-14
F3SG-4RA1360-14
F3SG-4RA1440-14
F3SG-4RA1520-14
F3SG-4RA1600-14
F3SG-4RA1680-14
F3SG-4RA1760-14
F3SG-4RA1840-14
F3SG-4RA1920-14
F3SG-4RA2000-14
F3SG-4RA2080-14
Hand and arm protection
104
108
112
116
120
124
92
96
100
76
80
84
88
64
68
72
Number of beams
Protective height
(mm)
8 190
12 270
16
20
24
350
430
510
44
48
52
56
60
28
32
36
40
590
670
750
830
910
990
1,070
1,150
1,230
2,110
2,190
2,270
2,350
2,430
2,510
1,310
1,390
1,470
1,550
1,630
1,710
1,790
1,870
1,950
2,030
Model
F3SG-4RA0190-30
F3SG-4RA0270-30
F3SG-4RA0350-30
F3SG-4RA0430-30
F3SG-4RA0510-30
F3SG-4RA0590-30
F3SG-4RA0670-30
F3SG-4RA0750-30
F3SG-4RA0830-30
F3SG-4RA0910-30
F3SG-4RA0990-30
F3SG-4RA1070-30
F3SG-4RA1150-30
F3SG-4RA1230-30
F3SG-4RA1310-30
F3SG-4RA1390-30
F3SG-4RA1470-30
F3SG-4RA1550-30
F3SG-4RA1630-30
F3SG-4RA1710-30
F3SG-4RA1790-30
F3SG-4RA1870-30
F3SG-4RA1950-30
F3SG-4RA2030-30
F3SG-4RA2110-30
F3SG-4RA2190-30
F3SG-4RA2270-30
F3SG-4RA2350-30
F3SG-4RA2430-30
F3SG-4RA2510-30
F3SG-RA
Accessories (Sold separately)
Single-ended Connector Cable
Appearance Type
For emitter
M12 connector
(5-pin), 5 wires
Color: Gray
For receiver
M12 connector
(8-pin), 8 wires
Color: Black
Cable length
3 m
7 m
10 m
15 m
20 m
3 m
7 m
10 m
15 m
20 m
Double-ended Cable
For cable extension and simple wiring
Appearance Type
For emitter
M12 connector
(5-pin) on both ends
Color: Gray
For receiver
M12 connector
(8-pin) on both ends
Color: Black
1
4
5
2
3
Female
7
6
1
8
5
2
4
3
Female
Specifications
1
2
3
4
5
+24 VDC
TEST
0 VDC
Not used
Not used
1
2
RESET
+24 VDC
3 MUTE A
4 MUTE B
5 OSSD 1
6
7
OSSD 2
0 VDC
8 AUX
Brown
Black
Blue
White
Yellow
Yellow
Brown
Gray
Pink
Black
White
Blue
Red
Cable length
0.5 m
1 m
3 m
5 m
7 m
10 m
15 m
20 m
0.5 m
1 m
3 m
5 m
7 m
10 m
15 m
20 m
Connected to Power Cable or Double-Ended Cable
1
4
5
2
3
2
4
5
1
3
Female
Brown
Blue
Black
White
Yellow
Connected to Power Cable or Double-Ended Cable
7
6
1
8
5
2
4
3
Female
3
4
1
8
5
6
2
7
Brown
Blue
Black
White
Yellow
Red
Gray
Pink
Specifications
Connected to Single-Ended Cable, or
Double-Ended cable
2
4
5
1
3
Brown
Blue
Black
White
Yellow
2
3
5
Male
1
4
Connected to Single-Ended Cable, or
Double-Ended cable
3
4
1
8
5
6
2
7
Brown
Blue
Black
White
Yellow
Red
Gray
Pink
3
4
2
8
5
Male
1
6
7
Y-Joint Plug/Socket Connector for Advance type F3SG-RA
Appearance Type Cable length Specifications
F3SG-RA
Emitter
F3SG-RA
Receiver
Model
F39-JG3A-L
F39-JG7A-L
F39-JG10A-L
F39-JG15A-L
F39-JG20A-L
F39-JG3A-D
F39-JG7A-D
F39-JG10A-D
F39-JG15A-D
F39-JG20A-D
Model
F39-JGR5B-L
F39-JG1B-L
F39-JG3B-L
F39-JG5B-L
F39-JG7B-L
F39-JG10B-L
F39-JG15B-L
F39-JG20B-L
F39-JGR5B-D
F39-JG1B-D
F39-JG3B-D
F39-JG5B-D
F39-JG7B-D
F39-JG10B-D
F39-JG15B-D
F39-JG20B-D
Model
M12 connectors.
Used for reduced wiring.
0.5 m
Y-Joint Plug/
Socket Connector for Advance
F39-GCNY2
Double-ended Cable
F39-JG
@B-L(Gray)
Single-ended Connector
Cable
F39-JG
@A-D(Black)
Cascading Cable (Two cables per set, for emitter and receiver)
Appearance Type Cable length
Secondary sensor 1
(Emitter)
Specifications
Secondary sensor 1
(Receiver)
Emitter cable:
Cap (5-pin), M12 connector (5-pin)
Receiver cable:
Cap (8-pin), M12 connector (8-pin)
0.2 m
Primary sensor
(Emitter)
Cascading Cable
F39-JGR2W
Primary sensor
(Receiver)
Cable
F39-JG
@@@-D
Cable
F39-JG
@@@-L
F39-GCNY2
Model
F39-JGR2W
13
F3SG-RA
Sensor Mounting Brackets
Appearance Specification
Standard Fixed
Bracket
Standard
Adjustable
Bracket
Top/Bottom
Adjustable Bracket *2
Top/Bottom
Adjustable Bracket *2
(For user-made mounting part)
Application
Bracket to mount the F3SG-R.
Side mounting and backside mounting possible.
(Included in the F3SG-R product package. See *1 below for the number of included brackets.)
Bracket to mount the F3SG-R.
Beam alignment after mounting possible.The angle adjustment range is
±15°.
Side mounting and backside mounting possible.
(Sold separately. See *1 below for the number of required brackets.)
Bracket to mount the F3SG-R. Use this bracket at the top and bottom positions of the F3SG-R.
Beam alignment after mounting possible.
The angle adjustment range is
±22.5°.
Side mounting and backside mounting possible.
(Sold separately. 4 brackets per set.)
Top/Bottom Adjustable Bracket without a bracket to mount to the wall. Use the user's own wall mounting part to suit the machine.
(Sold separately. 4 brackets per set.)
Model
F39-LGF
F39-LGA
F39-LGTB
F39-LGTB-1
*1 Two brackets per set
[for F3SG-
@RA@@@@-14]
- Protective height of 0160 to 1200: 2 sets, Protective height of 1280 to 2080: 3 sets
[for F3SG-
@RA@@@@-30]
- Protective height of 0190 to 1230: 2 sets, Protective height of 1310 to 2270: 3 sets, Protective height of 2350 to 2510: 4 sets
*2 Top/Bottom Adjustable Bracket cannot be used with the Standard Fixed Bracket. Use with the Standard Adjustable Bracket.
(See *1 for the number of required brackets.)
Interface units and configuration tool SD Manager 2
Appearance Type
SD Manager2
Specifications
The Configuration Tool SD Manager 2 is available to download from our website at http://www.ia.omron.com/f3sg-r_tool.
To change the settings of the F3SG-RA using
SD Manager 2, it is necessary to set the receiver's two DIP switches No. 8 to ON.
Model
−
Interface Unit
F39-GIF interface unit to connect the F3SG-RA receiver to a USB port of the PC
F39-GIF
14
Lamp
Appearance
End Cap
Appearance
Bluetooth unit
F39-BT bluetooth unit to enable bluetooth on the
F3SG-RA
F39-BT
Type Specifications
Lamp unit
The lamp unit can be connected to a receiver and turned ON based on the operation of F3SG-RA.
Bluetooth + Lamp unit
The lamp can indicate red, orange, and green colors, to which three different states can be assigned.
Model
F39-LP
F39-BTLP
Specifications
Housing color: Black
For both emitter and receiver
(Attached to the F3SG-R. The End Cap can be purchased if lost.)
Model
F39-CNM
F3SG-RA
Laser Pointer for F3SG-R
Appearance Specifications
The laser pointer is attached on the optical surface of the F3SG to help coarse adjustment of beams.
Model
F39-PTG
Spatter Protection Cover(Two covers per set, for emitter and receiver)
Spatter Protection Covers include mounting brackets.
For Safety Light Curtain models of the protective height of 2,000 mm or longer, use two Spatter Protection Covers of different lengths.
Appearance
Safety Light Curtain Model
Finger protection
F3SG-
@RA0160-14
Hand and arm protection
F3SG-
@RA0190-30
F3SG-
@RA0240-14
F3SG-
@RA0320-14
F3SG-
@RA0400-14
F3SG-
@RA0480-14
F3SG-
@RA0560-14
F3SG-
@RA0640-14
F3SG-
F3SG-
F3SG-
F3SG-
F3SG-
F3SG-
@RA0270-30
@RA0350-30
@RA0430-30
@RA0510-30
@RA0590-30
@RA0670-30
F3SG-
@RA0720-14
F3SG-
@RA0800-14
F3SG-
@RA0880-14
F3SG-
@RA0960-14
F3SG-
@RA1040-14
F3SG-
@RA1120-14
F3SG-
@RA1200-14
F3SG-
F3SG-
F3SG-
F3SG-
F3SG-
F3SG-
F3SG-
@RA0750-30
@RA0830-30
@RA0910-30
@RA0990-30
@RA1070-30
@RA1150-30
@RA1230-30
F3SG-
@RA1280-14
F3SG-
@RA1360-14
F3SG-
@RA1440-14
F3SG-
@RA1520-14
F3SG-
@RA1600-14
F3SG-
@RA1680-14
F3SG-
@RA1760-14
F3SG-
@RA1840-14
F3SG-
@RA1920-14
F3SG-
@RA1310-30
F3SG-
@RA1390-30
F3SG-
@RA1470-30
F3SG-
@RA1550-30
F3SG-
@RA1630-30
F3SG-
@RA1710-30
F3SG-
F3SG-
F3SG-
@RA1790-30
@RA1870-30
@RA1950-30
F3SG-
@RA2000-14
F3SG-
@RA2080-14
−
−
−
−
−
F3SG-
@RA2030-30
F3SG-
@RA2110-30
F3SG-
@RA2190-30
F3SG-
@RA2270-30
F3SG-
@RA2350-30
F3SG-
@RA2430-30
F3SG-
@RA2510-30
Model
F39-HGA1320
F39-HGA1400
F39-HGA1480
F39-HGA1560
F39-HGA1640
F39-HGA1720
F39-HGA1800
F39-HGA1880
F39-HGA1960
F39-HGA1480
F39-HGA0550
F39-HGA1560
F39-HGA0550
F39-HGA1640
F39-HGA0550
F39-HGA0200
F39-HGA0280
F39-HGA0360
F39-HGA0440
F39-HGA0520
F39-HGA0600
F39-HGA0680
F39-HGA0760
F39-HGA0840
F39-HGA0920
F39-HGA1000
F39-HGA1080
F39-HGA1160
F39-HGA1240
F39-HGA1720
F39-HGA0550
F39-HGA1800
F39-HGA0550
F39-HGA1880
F39-HGA0550
F39-HGA1960
F39-HGA0550
Note: The operating range of the Safety Light Curtain attached with the product is 10% shorter than the rating.
Test Rod
Diameter
14 mm dia.
30 mm dia.
Model
F39-TRD14
F39-TRD30
15
16
F3SG-RA
Ratings and Specifications
Main unit
Type of ESPE (IEC 61496-1)
Performance
Electrical
Functional
Object Resolution
(Detection Capability)
Beam Gap
Number of Beams
Lens Size
Protective Height
Type 4
Type 2
F3SG-4RA
-14
F3SG-2RA
-14
F3SG-4RA
-14/-30
F3SG-2RA
-14/-30
Opaque objects
14-mm dia.
10 mm
15 to 207
5.2 × 3.4 (W × H) mm
160 to 2080 mm (6.3 to 81.9 inch)
F3SG-4RA
-30
F3SG-2RA
-30
30-mm dia.
20 mm
8 to 124
7-mm dia.
190 to 2510 mm (7.3 to 98.7 inch)
Operating Range
Long
Short
ON to OFF
OFF to ON
0.3 to 10.0 m (1 to 32 ft.)
0.3 to 3.0 m (1 to 10 ft.)
Normal mode: 8 to 18 ms max. *1
Slow mode: 16 to 36 ms max. *1 *2
40 to 90 ms max. *1
0.3 to 20.0 m (1 to 65 ft.)
0.3 to 7.0 m (1 to 23 ft.)
Response Time
*1 Response time when used in one segment system or in cascaded connection.
Refer to page 18.
*2 Selectable by Configuration Tool.
Effective Aperture Angle
(EAA) (IEC 61496-2)
Type 4
Type 2
Light Source
Startup Waiting Time
Power Supply Voltage (Vs)
Current Consumption
±2.5° max., emitter and receiver at operating range of 3 m or greater
±5.0° max., emitter and receiver at operating range of 3 m or greater
Infrared LEDs, Wavelength: 870 nm
2 s max.
SELV/PELV 24 VDC±20% (ripple p-p 10% max.)
Refer to page18 .
Two PNP or NPN transistor outputs (PNP or NPN is selectable by DIP Switch.)
Load current of 300 mA max., Residual voltage of 2 V max. (except for voltage drop due to cable extension), Capacitive load of 1
μF max., Inductive load of 2.2 H max. *1
Leakage current of 1 mA max. (PNP), 2 mA max. (NPN) *2
Safety Outputs (OSSD)
Auxiliary Output
Output Operation
Mode
Input Voltage
Safety Output
Auxiliary Output
ON Voltage
OFF Voltage
*1 The load inductance is the maximum value when the safety output frequently repeats ON and
OFF. When you use the safety output at 4 Hz or less, the usable load inductance becomes larger.
*2 These values must be taken into consideration when connecting elements including a capacitive load such as a capacitor.
One PNP or NPN transistor output (PNP or NPN is selectable by DIP Switch.)
Load current of 100 mA max., Residual voltage of 2 V max .
Light-ON (Safety output is enabled when the receiver receives an emitting signal.)
Muting or Override output (default) (Configurable by Configuration Tool)
TEST:
24 V Active: 9 V to Vs (sink current 3 mA max.) *
0 V Active: 0 to 3 V (source current 3 mA max.)
MUTE A/B:
PNP: Vs to Vs-3 V (sink current 3 mA max.) *
NPN: 0 to 3 V (source current 3 mA max.)
RESET:
PNP: Vs to Vs-3 V (sink current 5 mA max.) *
NPN: 0 to 3 V (source current 5 mA max.)
TEST:
24 V Active : 0 to 1.5 V or open
0 V Active : 9 V to Vs or open
MUTE A/B, RESET:
PNP: 0 to 1/2 Vs, or open *
NPN: 1/2 Vs to Vs, or open *
* The Vs indicates a supply voltage value in your environment.
Overvoltage Category (IEC 60664-1)
II
Indicators
Refer to page 20.
Protective Circuit
Insulation Resistance
Dielectric Strength
Mutual Interference Prevention (Scan Code)
Cascade Connection
Test Function
Safety-Related Functions
Output short protection, Power supply reverse polarity protection
20 M
Ω or higher (500 VDC megger)
1,000 VAC, 50/60 Hz (1 min)
This function prevents mutual interference in up to two F3SG-RA systems.
Number of cascaded segments: 3 max.
Total number of beams: 255 max.
Cable lengths between sensors: 10 m max.
Self-test (at power-on, and during operation)
External test (light emission stop function by test input)
Interlock
External device monitoring (EDM)
Pre-reset
Fixed blanking/Floating blanking
Reduced resolution
Muting/Override
Scan code selection
PNP/NPN selection
Response time adjustment
F3SG-RA
Environmental
Connections
Ambient Temperature
Ambient Humidity
Operating
Storage
Operating
Storage
Ambient Illuminance
Degree of Protection (IEC 60529)
Vibration Resistance (IEC 61496-1)
Shock Resistance (IEC 61496-1)
Pollution Degree (IEC 60664-1)
Power cable
Type of Connection
Number of Wires
Cable Length
Cable Diameter
Minimum Bending
Radius
Cascading cable
Type of Connection
Number of Wires
Cable Length
Cable Diameter
Minimum Bending
Radius
Extension cable
- Single-ended cable
- Double-ended cable
Type of Connection
Number of Wires
Cable Length
Cable Diameter
Minimum Bending
Radius
Extension of Power Cable
Material
Material
Weight (packaged)
Included Accessories
Conformity
Conforming standards
Type of ESPE (IEC 61496-1)
Performance Level
(PL)/Safety category
Type 4
Type 2
PFHd
Proof test interval T
M
SFF
HFT
Classification
Bluetooth Communication Unit
Communication System
Communication Profile
Transmission Distance
* It depends on use environment conditions.
F3SG-4RA
-14
F3SG-2RA
-14
F3SG-4RA
-30
F3SG-2RA
-30
-10 to 55°C (14 to 131°F) (non-icing)
-25 to 70°C (-13 to 158°F)
35% to 85% (non-condensing)
35% to 95%
Incandescent lamp: 3,000 Ix max. on receiver surface
Sunlight: 10,000 Ix max. on receiver surface
IP65 and IP67
10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps for all 3 axes
100 m/s 2 , 1000 shocks for all 3 axes
Pollution Degree 3
M12 connectors: 5-pin emitter and 8-pin receiver, IP67 rated when mated, Cables prewired to the sensors
Emitter: 5, Receiver: 8
0.3 m
6 mm
R5 mm
M12 connectors: 5-pin emitter and 8-pin receiver, IP67 rated when mated
Emitter: 5, Receiver: 8
0.2 m
6 mm
R5 mm
M12 connectors: 5-pin emitter and 8-pin receiver, IP67 rated when mated
Emitter: 5, Receiver: 8
Refer to page 13.
6.6 mm
R36 mm
100 m max.
Housing: Aluminum
Cap: PBT
Front window: PMMA
Cable: Oil resistant PVC
Mounting Bracket: ZDC2
FE plate: SUS
Refer to page18 .
Safety Precautions, Quick Installation Manual, Standard Fixed Bracket*, Troubleshooting Guide
Sticker, Warning Zone Label
* The quantity of Standard Fixed Brackets included varies depending on the protective height.
[F3SG-
RA-14]
- Protective height of 0160 to 1200: 2 sets
- Protective height of 1280 to 2080: 3 sets
[F3SG-
RA-30]
- Protective height of 0190 to 1230: 2 sets
- Protective height of 1310 to 2270: 3 sets
- Protective height of 2350 to 2510: 4 sets
Refer to page 19.
Type 4
PL e/Category 4 (EN ISO 13849-1:2008)
PL c/Category 2 (EN ISO 13849-1:2008)
1.1 × 10 -8 (IEC 61508)
Every 20 years (IEC 61508)
99% (IEC 61508)
1 (IEC 61508)
Type B (IEC 61508-2)
Bluetooth Version 3.0
SPP (Serial Port Profile)
Approx. 10 m max. (Output power: Class 2) *
17
18
F3SG-RA
List of Models/Response Time/Current Consumption/Weight
F3SG-4RA
-14/F3SG-2RA-14
Protective
Height
[mm]
ON
→
OFF *1
Response Time [ms]
OFF
(Not synchronized)
→ ON
140
140
140
140
165
165
165
165
165
165
165
165
165
165
165
165
190
190
190
190
190
190
190
190
190
Current
Consumption [mA]
Model
F3SG-4RA0160-14 F3SG-2RA0160-14
F3SG-4RA0240-14 F3SG-2RA0240-14
F3SG-4RA0320-14 F3SG-2RA0320-14
F3SG-4RA0400-14 F3SG-2RA0400-14
F3SG-4RA0480-14 F3SG-2RA0480-14
F3SG-4RA0560-14 F3SG-2RA0560-14
F3SG-4RA0640-14 F3SG-2RA0640-14
F3SG-4RA0720-14 F3SG-2RA0720-14
F3SG-4RA0800-14 F3SG-2RA0800-14
F3SG-4RA0880-14 F3SG-2RA0880-14
F3SG-4RA0960-14 F3SG-2RA0960-14
F3SG-4RA1040-14 F3SG-2RA1040-14
F3SG-4RA1120-14 F3SG-2RA1120-14
F3SG-4RA1200-14 F3SG-2RA1200-14
F3SG-4RA1280-14 F3SG-2RA1280-14
F3SG-4RA1360-14 F3SG-2RA1360-14
F3SG-4RA1440-14 F3SG-2RA1440-14
F3SG-4RA1520-14 F3SG-2RA1520-14
F3SG-4RA1600-14 F3SG-2RA1600-14
F3SG-4RA1680-14 F3SG-2RA1680-14
F3SG-4RA1760-14 F3SG-2RA1760-14
F3SG-4RA1840-14 F3SG-2RA1840-14
F3SG-4RA1920-14 F3SG-2RA1920-14
F3SG-4RA2000-14 F3SG-2RA2000-14
F3SG-4RA2080-14 F3SG-2RA2080-14
Number of
Beams
79
87
95
103
111
119
127
135
47
55
63
71
15
23
31
39
143
151
159
167
175
183
191
199
207
13
13
13
13
13
13
13
13
13
13
13
13
8
8
8
8
18
18
18
18
18
18
18
18
18
800
880
960
1040
1120
1200
1280
1360
160
240
320
400
480
560
640
720
1440
1520
1600
1680
1760
1840
1920
2000
2080
OFF
(Synchronized)
→ ON
40
40
40
40
65
65
65
65
65
65
65
65
65
65
90
90
90
90
65
65
90
90
90
90
90
Emitter Receiver
95
100
100
105
90
90
90
95
80
80
85
85
75
75
75
80
105
105
110
110
115
115
120
120
125
85
90
95
95
65
70
75
80
50
55
60
65
40
45
55
60
100
100
105
105
110
85
90
90
95
Weight
[kg]
*2
*1 The response times are values when Scan Code is set at Code B. The response times for Code A are 1 ms shorter than these values.
*2 The weight includes an emitter, a receiver and included brackets in a product package.
4.8
5.0
5.2
5.6
4.1
4.3
4.5
4.7
2.9
3.1
3.3
3.9
1.8
2.0
2.2
2.7
7.0
7.2
7.3
7.5
8.1
5.8
6.0
6.6
6.8
F3SG-4RA
-30/F3SG-2RA-30
Model
F3SG-4RA0190-30 F3SG-2RA0190-30
F3SG-4RA0270-30 F3SG-2RA0270-30
F3SG-4RA0350-30 F3SG-2RA0350-30
F3SG-4RA0430-30 F3SG-2RA0430-30
F3SG-4RA0510-30 F3SG-2RA0510-30
F3SG-4RA0590-30 F3SG-2RA0590-30
F3SG-4RA0670-30 F3SG-2RA0670-30
F3SG-4RA0750-30 F3SG-2RA0750-30
F3SG-4RA0830-30 F3SG-2RA0830-30
F3SG-4RA0910-30 F3SG-2RA0910-30
F3SG-4RA0990-30 F3SG-2RA0990-30
F3SG-4RA1070-30 F3SG-2RA1070-30
F3SG-4RA1150-30 F3SG-2RA1150-30
F3SG-4RA1230-30 F3SG-2RA1230-30
F3SG-4RA1310-30 F3SG-2RA1310-30
F3SG-4RA1390-30 F3SG-2RA1390-30
F3SG-4RA1470-30 F3SG-2RA1470-30
F3SG-4RA1550-30 F3SG-2RA1550-30
F3SG-4RA1630-30 F3SG-2RA1630-30
F3SG-4RA1710-30 F3SG-2RA1710-30
F3SG-4RA1790-30 F3SG-2RA1790-30
F3SG-4RA1870-30 F3SG-2RA1870-30
F3SG-4RA1950-30 F3SG-2RA1950-30
F3SG-4RA2030-30 F3SG-2RA2030-30
F3SG-4RA2110-30 F3SG-2RA2110-30
F3SG-4RA2190-30 F3SG-2RA2190-30
F3SG-4RA2270-30 F3SG-2RA2270-30
F3SG-4RA2350-30 F3SG-2RA2350-30
F3SG-4RA2430-30 F3SG-2RA2430-30
F3SG-4RA2510-30 F3SG-2RA2510-30
Number of
Beams
100
104
108
112
116
120
124
84
88
92
96
68
72
76
80
52
56
60
64
36
40
44
48
8
12
16
20
24
28
32
Protective
Height
[mm]
2030
2110
2190
2270
2350
2430
2510
1390
1470
1550
1630
1710
1790
1870
1950
750
830
910
990
1070
1150
1230
1310
190
270
350
430
510
590
670
ON
→
OFF
*1
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
8
8
13
13
8
8
8
8
8
8
8
Response Time [ms]
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
OFF
(Synchronized)
→ ON
40
40
40
40
40
65
65
65
65
40
40
40
40
165
165
165
165
165
165
165
165
165
165
165
165
165
165
165
165
165
OFF
(Not synchronized)
→ ON
140
140
140
140
140
140
140
140
140
165
165
165
165
Current
Consumption [mA]
Emitter Receiver
80
80
85
85
85
90
90
70
70
75
75
60
65
65
70
55
55
55
60
60
65
50
50
35
35
40
45
50
50
55
Weight
[kg]
*2
*1 The response times are values when Scan Code is set at Code B. The response times for Code A are 1 ms shorter than these values.
The maximum speed of movement of a test rod up to which the detection capability is maintained is 2.0 m/s.
*2 The weight includes an emitter, a receiver and included brackets in a product package.
95
95
95
100
100
100
100
90
90
90
95
85
85
90
90
80
85
85
85
80
80
80
80
75
75
75
75
75
75
75
7.4
8.0
8.2
8.4
8.8
8.9
9.1
6.7
6.9
7.1
7.3
5.6
5.8
6.0
6.5
4.6
4.8
4.9
5.1
3.9
4.0
4.2
4.4
1.8
2.0
2.2
2.7
2.9
3.1
3.3
F3SG-RA
Legislation and Standards
1. The F3SG-R does not receive type approval provided by Article 44-2 of the Industrial Safety and Health Act of Japan. When using the F3SG-R in Japan as a "safety system for pressing or shearing machines" prescribed in Article 42 of that law, the machine control system must receive type approval.
2. The F3SG-R is electro-sensitive protective equipment (ESPE) in accordance with European Union (EU) Machinery Directive Index Annex V,
Item 2.
3. EC Declaration of Conformity
OMRON declares that the F3SG-R is in conformity with the requirements of the following EC Directives:
Machinery Directive 2006/42/EC
EMC Directive 2004/108/EC
4. Conforming Standards
(1) European standards
EN61496-1 (Type 4 and Type 2 ESPE), EN 61496-2 (Type 4 and Type 2 AOPD), EN61508-1 through -4 (SIL 3 for Type 4 and SIL 1 for
Type 2), EN ISO 13849-1:2008 (PL e, Category 4 for Type 4 and PL c, Category 2 for Type 2)
(2) International standards
IEC61496-1 (Type 4 and Type 2 ESPE), IEC61496-2 (Type 4 and Type 2 AOPD), IEC61508-1 through -4 (SIL 3 for Type 4 and SIL 1 for
Type 2), ISO 13849-1:2006 (PL e, Category 4 for Type 4 and PL c, Category 2 for Type 2)
(3) JIS standards
JIS B 9704-1 (Type 4 and Type 2 ESPE), JIS B 9704-2 (Type 4 and Type 2 AOPD)
(4) North American standards
UL61496-1(Type 4 and Type 2 ESPE), UL61496-2(Type 4 and Type 2 AOPD), UL508, UL1998,
CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8
(5) Chinese standards
GB4584(Specification of active opto-electronic protective devices for presses)
5. Third-Party Certifications
(1) TÜV SÜD
• EC Type-Examination certificate:
EU Machinery Directive, Type 4 and Type 2 ESPE (EN61496-1), Type 4 and Type 2 AOPD (EN 61496-2)
• Certificate:
Type 4 and Type 2 ESPE (EN61496-1), Type 4 and Type 2 AOPD (EN61496-2), EN 61508-1 through -4 (SIL 3 for Type 4 and SIL 1 for
Type 2), EN ISO 13849-1:2008 (PL e, Category 4 for Type 4, and PL c, Category 2 for Type 2)
(2) UL
• UL Listing:
Type 4 and Type 2 ESPE (UL61496-1), Type 4 and Type 2 AOPD (UL61496-2), UL508, UL1998, CAN/CSA C22.2 No.14, CAN/CSA C22.2
No.0.8
(3) China National Casting and Forging Machines Quality Supervision and Inspection Center
• Certificate:
GB4584 (Specification of active opto-electronic protective devices for presses)
6. Other Standards
The F3SG-R is designed according to the standards listed below. To make sure that the final system complies with the following standards and regulations, you are asked to design and use it in accordance with all other related standards, laws, and regulations. If you have any questions, consult with specialized organizations such as the body responsible for prescribing and/or enforcing machinery safety regulations in the location where the equipment is to be used.
• European Standards: EN415-4, EN691-1, EN692, EN693, IEC/TS 62046
• U.S. Occupational Safety and Health Standards: OSHA 29 CFR 1910.212
• U.S. Occupational Safety and Health Standards: OSHA 29 CFR 1910.217
• American National Standards: ANSI B11.1 to B11.19
• American National Standards: ANSI/RIA R15.06
• Canadian Standards Association CSA Z142, Z432, Z434
• SEMI Standards SEMI S2
• Japan Ministry of Health, Labour and Welfare "Guidelines for Comprehensive Safety Standards of Machinery", Standard Bureau's Notification
No. 0731001 dated July 31, 2007.rms and Conditions Agreement
• Chinese National Standards: GB17120, GB27607
19
20
F3SG-RA
Indicator
Emitter
Test
Name of Indicator
TEST
Operating range LONG
Power
Lockout
POWER
LOCKOUT
Receiver
Name of Indicator
Top-beam-state
PNP/NPN mode
Response time
Sequence error
Blanking
TOP
NPN
SLOW
SEQ
BLANK
Configuration
Interlock
External device monitoring
Internal error
Lockout
Stable-state
ON/OFF
CFG
INT-LK
EDM
INTERNAL
LOCKOUT
STB
ON/OFF
Color
Green
Green
Green
Red
Illuminated
−
Long range mode is selected
Power is ON.
−
Blinking
External Test is being performed
Lockout state due to DIP Switch setting error or Operating range selection setting error
Error due to noise
Lockout state due to error in emitter
Color
Blue
Green
Green
Yellow
Green
Red
Red
Green
Green
Red
Green
Yellow
Green
Green
Blue
Illuminated
The top beam is unblocked
NPN mode is selected by DIP Switch
Response Time Adjustment is enabled
−
Blanking, Warning Zone or Reduced Resolution is enabled
Blinking
Muting/Override state, or Lockout state due to Cap error or Other sensor error
−
−
Sequence error in Muting or Pre-reset mode
Teach-in mode, or Blanking Monitoring error
−
Interlock state
RESET input is in ON state
Teach-in mode, zone measurement beng performed by Dynamic Muting, or Lockout state due to
Parameter error or Cascading Configuration error
Pre-reset mode
Lockout state due to EDM error
−
−
The bottom beam is unblocked
Lockout state due to Internal error, or error due to abnormal power supply or noise
Lockout state due to error in receiver
Incident light level is 170% or higher of ON-threshold
Safety output is in ON state
Safety output is instantaneously turned OFF due to ambient light or vibration
−
Safety output is in OFF state, or the sensor is in
Setting state
Lockout state due to Safety Output error, or error due to abnormal power supply or noise
Synchronization between emitter and receiver is maintained
Lockout state due to Communication error, or error due to abnormal power supply or noise
Muting/Override state, or Lockout state due to DIP
Switch setting error
Communication
Bottom-beam-state
Interface Unit
Main unit
Operating system (OS)
Communication port
Ambient temperature
Ambient humidity
Lamp
Item
Applicable Sensor
LED Light Color
Power Supply Voltage
Current Consumption
Ambient Temperature
Ambient Humidity
Vibration Resistance
Shock Resistance
Degree of Protection
Type of Connection
Material
Weight
COM
BTM
PC/AT compatible machine (computer that runs Microsoft Windows)
Windows 7 (32-bit/64-bit), Windows 8 (32-bit/64-bit)
USB port
×1
Operating: -10 to 55
°C, Storage: -30 to 70°C(non-icing and non-condensing)
Operating: 35% to 85%, Storage: 35% to 95%(non-condensing)
F39-LP
F3SG-
@RA Series Safety Light Curtain (Receiver)
Red/Green/Orange
24 VDC
±20%, ripple p-p 10% max.(shares sensor′s power supply)
25 mA max. (shares sensor
′s power supply.)
Operating: -10 to 55
°C, Storage: -25 to 70°C
Operating: 35% to 85%, Storage: 35% to 95%
10 to 55 Hz, Multiple amplitude of 0.7 mm,20 sweeps for all 3 axes
100 m/s
2
, 1000 shocks for all 3 axes
IP65 and IP67(When attached to F3SG)
Connectable to F3SG-RA
′s terminal connector
Lighting element: PC, Other body parts: PBT
45 g (when packaged)
F3SG-RA
Connections (Basic Wiring Diagram)
Standalone F3SG-RA using PNP Outputs
The following is the example of External Device Monitoring enabled, Manual Reset mode, PNP output and External Test in 24 V Active.
DIP Switch settings *2
Receiver
Emitter
EDM Enabled
Manual Reset
Function
PNP (factory default setting)
External Test: 24 V Active (factory default setting)
3
4
7
2
DIP-SW1
ON 2
DIP-SW2
ON
ON
ON
ON
3
4
7
ON
ON
ON
4 ON
: Indicates a switch position.
Configure functions with the DIP Switches before wiring.
Wiring Example
F39-JG
@A-L
F39-JG
@A-D
S2
KM1 KM2
S1
KM1
KM2
KM1
KM2
M
+24 VDC
Power Supply
0 VDC
S1: Test Switch (Connect the line to 0 V
if this switch is not required)
Functional Earth
S2: Lockout/Interlock Reset Switch
KM1, KM2: Safety relay with forcibly guided contacts (G7SA)
or magnetic contactor
M: 3-phase motor
*1.Also used as EDM input line.
*2.The functions are configurable with DIP Switch. Refer to
Safety Light Curtain F3SG-R Series User's Manual for more information on setting the functions by the DIP Switch.
Beam state
Unblocked
Blocked
Test Switch (S1)
Reset Switch (S2)
OSSD
Note: The wiring examples in later pages do not indicate functional earth. To use functional earth, wire an earth cable according to the example above. Refer to Safety Light Curtain F3SG-R Series User's Manual for more information.
21
22
F3SG-RA
Standalone F3SG-RA with Y-Joint Plug/Socket Connector using PNP outputs
The following is the example of External Device Monitoring enabled, Manual Reset mode, PNP output and External Test in 24 V Active.
DIP Switch settings *3
Receiver
Emitter
EDM Enabled
Manual Reset
Function
PNP (factory default setting)
External Test: 24 V Active (factory default setting)
3
4
7
2
DIP-SW1
ON 2
DIP-SW2
ON
ON
ON
ON
3
4
7
ON
ON
ON
4 ON
: Indicates a switch position.
Configure functions with the DIP Switches before wiring.
Wiring Example
F39-JG
@B-L
F39-GCNY2
F39-JG
@A-D
S1
KM1 KM2
+24 VDC
Power supply
0 VDC
KM1
KM2
IN
PLC *2
S1: Lockout/Interlock Reset Switch
KM1,KM2: External device feedback
M: 3-phase motor
PLC: Programmable controller
(Used for monitoring only. NOT related to safety system.)
*1.Also used as EDM input line.
*2.When connecting to the PLC, the output mode must be changed with the Configuration Tool.
*3.The functions are configurable with DIP Switch. Refer to
Safety Light Curtain F3SG-R Series User's Manual for more information on setting the functions by the DIP Switch.
M
Beam state
Unblocked
Blocked
Reset Switch (S1)
OSSD
KM1
KM2
F3SG-RA
F3SG-RA with Y-Joint Plug/Socket Connector in Standard Muting Mode/Exit-Only
Muting Mode using PNP outputs
The following is the example of External Device Monitoring disabled, Auto Reset mode, PNP output and External Test in 24 V Active.
DIP Switch settings *5
Function
EDM Disabled (factory default setting)
Receiver
Emitter
Auto Reset (factory default setting)
PNP (factory default setting)
External Test: 24 V Active (factory default setting)
3
4
7
2
DIP-SW1
ON
ON
ON
ON
2
3
4
7
DIP-SW2
ON
ON
ON
ON
4 ON
: Indicates a switch position.
Configure functions with the DIP Switches before wiring.
Wiring Example
F39-JG
@B-L
F39-GCNY2
F39-JG
@A-D
S1
*2
ML
IN1 IN2
S1: Lockout/Interlock Reset Switch,
Override Switch or Override Cancel Switch
ML: Muting Lamp
Safety
Controller *3 *4
*1.Also used as EDM input line.
*2.Make sure to connect an override cancel switch to the Reset line when using the override function. Otherwise the override state may not be released by the override cancel switch, resulting in serious injury.
*3.Refer to page 27 for more information.
*4.The safety controller and the F3SG-R must share the power supply or be connected to the common terminal of the power supply.
*5.The functions are configurable with DIP Switch. Refer to
Safety Light Curtain F3SG-R Series User's Manual for more information on setting the functions by the DIP Switch.
Beam state
Unblocked
Blocked
MUTE A
MUTE B
OSSD
+24V DC
Power supply
0V
23
24
F3SG-RA
Standard Muting Mode/Exit-Only Muting Mode using PNP Outputs
The following is the example of External Device Monitoring disabled, Auto Reset mode, PNP output and External Test in 24 V Active.
DIP Switch settings *6
Function
EDM Disabled (factory default setting)
Receiver
Emitter
Auto Reset (factory default setting)
PNP (factory default setting)
External Test: 24 V Active (factory default setting)
3
4
7
2
DIP-SW1
ON 2
DIP-SW2
ON
ON
ON
ON
3
4
7
ON
ON
ON
4 ON
: Indicates a switch position.
Configure functions with the DIP Switches before wiring.
Wiring Example
F39-JG
@A-L
F39-JG
@A-D
S1
S2
*2
ML
S1: Test Switch (Connect the line to 0 V if this switch
is not required)
S2: Lockout/Interlock Reset Switch,
Override Switch
or Override Cancel Switch
ML: Muting lamp
Muting
Actuator *5
IN1 IN2
Safety
Controller *3 *4
*1.Also used as Override input line.
*2.Make sure to connect an override cancel switch to the Reset line when using the override function. Otherwise the override state may not be released by the override cancel switch, resulting in serious injury.
*3.Refer to page 27 for more information.
*4.The safety controller and the F3SG-R must share the power supply or be connected to the common terminal of the power supply.
*5.Refer to Smart Muting Actuator F3W-MA Series User's Manual for more information.
*6.The functions are configurable with DIP Switch. Refer to
Safety Light Curtain F3SG-R Series User's Manual for more information on setting the functions by the DIP Switch.
Beam state
Unblocked
Blocked
Test Switch (S1)
MUTE A
MUTE B
OSSD
+24 VDC
Power Supply
0 VDC
F3SG-RA
Standard Muting Mode/Exit-Only Muting Mode with two Muting Sensors using PNP Outputs
The following is the example of External Device Monitoring disabled, Auto Reset mode, PNP output and External Test in 24 V Active.
DIP Switch settings *5
Function
EDM Disabled (factory default setting)
Receiver
Emitter
Auto Reset (factory default setting)
PNP (factory default setting)
External Test: 24 V Active (factory default setting)
3
4
7
2
DIP-SW1
ON 2
DIP-SW2
ON
ON
ON
ON
3
4
7
ON
ON
ON
4 ON
: Indicates a switch position.
Configure functions with the DIP Switches before wiring.
Wiring Example
F39-JG
@A-L
F39-JG
@A-D
ML
S1
S2
*2
IN1 IN2
Safety
Controller *3 *4
A1
Muting
Sensor
(PNP output)
B1
+24 VDC
Power Supply
0 VDC
Reflector
S1: Test Switch (Connect the line to 0 V if this switch is not required)
S2: Lockout/Interlock Reset Switch,Override Switch or Override Cancel Switch
ML: Muting lamp
A1, B1: Muting sensor
Beam state
Unblocked
Blocked
Test Switch (S1)
MUTE A
*1.Also used as Override input line.
*2.Make sure to connect an override cancel switch to the Reset line when using the override function. Otherwise the override state may not be released by the override cancel switch, resulting in serious injury.
*3.Refer to page 27 for more information.
*4.The safety controller and the F3SG-R must share the power supply or be connected to the common terminal of the power supply.
*5.The functions are configurable with DIP Switch. Refer to Safety
Light Curtain F3SG-R Series User's Manual for more information on setting the functions by the DIP Switch.
MUTE B
OSSD
25
F3SG-RA
Standard Muting Mode with four Muting Sensors using PNP Outputs
The following is the example of External Device Monitoring disabled, Auto Reset mode, PNP output and External Test in 24 V Active.
DIP Switch settings *5
Function
EDM Disabled (factory default setting)
Receiver
Emitter
Auto Reset (factory default setting)
PNP (factory default setting)
External Test: 24 V Active (factory default setting)
3
4
7
2
DIP-SW1
ON 2
DIP-SW2
ON
ON
ON
ON
3
4
7
ON
ON
ON
4 ON
: Indicates a switch position.
Configure functions with the DIP Switches before wiring.
Wiring Example
F39-JG
@A-L
F39-JG
@A-D
26
S1
S2
*2
ML
IN1 IN2
Safety
Controller *3 *4
Reflector
B1
B2
Muting
Sensor
(PNP output)
A1 A2
+24 VDC
Power Supply
0 VDC
S1: Test Switch (Connect the line to 0 V if this
switch is not required)
S2: Lockout/Interlock Reset Switch,
Override Switch or Override Cancel Switch
ML: Muting lamp
A1, A2, B1, B2: Muting sensor
*1.Also used as Override input line.
*2.Make sure to connect an override cancel switch to the Reset line when using the override function. Otherwise the override state may not be released by the override cancel switch, resulting in serious injury.
*3.Refer to page 27 for more information.
*4.The safety controller and the F3SG-R must share the power supply or be connected to the common terminal of the power supply.
*5.The functions are configurable with DIP Switch. Refer to Safety Light Curtain
F3SG-R Series User's Manual for more information on setting the functions by the DIP Switch.
Beam state
Unblocked
Blocked
Test Switch (S1)
MUTE A
MUTE B
OSSD
F3SG-RA
Pre-Resest Mode using PNP Output
The following is the example of External Device Monitoring disabled, Pre-Reset mode, PNP output and External Test in 24 V Active.
DIP Switch settings *4
Receiver
Emitter
Function
EDM Disabled (factory default setting)
Pre-Reset
PNP (factory default setting)
External Test: 24 V Active (factory default setting)
2
3
4
7
DIP-SW1
ON
ON
ON
ON
2
3
4
7
DIP-SW2
ON
ON
ON
ON
4 ON
: Indicates a switch position.
Configure functions with the DIP Switches before wiring.
Wiring Example
F39-JG
@A-L
F39-JG
@A-D
S2 S3
S1
+24 VDC
Power Supply
0 VDC
S1: Test Switch (Connect the line to 0 V if this switch is
not required)
S2: Lockout/Interlock Reset Switch
S3: Pre-Reset Switch
PLC: Programmable controller
(Used for monitoring only. NOT related to safety system.)
IN
PLC *3
IN1 IN2
Safety
Controller *1 *2
*1.Refer to the following list "Connectable Safety Control
Units" on this page.
*2.The safety controller and the F3SG-R must share the power supply or be connected to the common terminal of the power supply.
*3.When connecting to the PLC, the output mode must be changed with the Configuration Tool.
*4.The functions are configurable with DIP Switch. Refer to
Safety Light Curtain F3SG-R Series User's Manual for more information on setting the functions by the DIP
Switch.
Pre-Reset Switch (S3)
Beam state
Unblocked
Blocked
Reset Switch (S2)
OSSD
T1
T2
T3
T1: Push time: must be T1 >= 300ms
T2: Pre-reset limit time between Pre-reset and Reset: must be T2 <= 60s
T3: Push time: must be T3 >= 300ms
Connectable Safety Control Units
The F3SG-RA with PNP output can be connected to the safety control units listed in the table below.
Connectable Safety Control Units (PNP output)
G9SA-301
G9SA-321
G9SA-501
G9SB-200-B
G9SB-200-D
G9SB-301-B
G9SB-301-D
G9SE-201
G9SE-401
G9SE-221-T
@
G9SX-AD322-T
G9SX-ADA222-T
G9SX-BC202
G9SX-GS226-T15
G9SP-N10S
G9SP-N10D
G9SP-N20S
NE0A-SCPU01
NE1A-SCPU01
NE1A-SCPU02
DST1-ID12SL
DST1-MD16SL
DST1-MRD08SL
NX-SIH400
NX-SID800
F3SP-T01
27
28
F3SG-RA
Standalone F3SG-RA using NPN Outputs
The following is the example of External Device Monitoring enabled, Manual Reset mode, NPN output and External Test in 0 V Active.
DIP Switch settings *2
Receiver
Emitter
EDM Enabled
Manual Reset
Function
NPN
External Test: 0 V Active
3
4
7
2
DIP-SW1
ON 2
DIP-SW2
ON
ON
ON
ON
3
4
7
ON
ON
ON
4 ON
: Indicates a switch position.
Configure functions with the DIP Switches before wiring.
Wiring Example
F39-JG
@A-L
F39-JG
@A-D
+24 VDC
Power Supply
0 VDC
S1
KM1 KM2
S2
KM1
KM2
KM1
KM2
Beam state
Unblocked
Blocked
Test Switch (S1)
Reset Switch (S2)
OSSD
S1: Test Switch (Connect the line to 24 V if this switch is not required)
S2: Lockout/Interlock Reset Switch
KM1, KM2: Safety relay with forcibly guided contacts (G7SA)
or magnetic contactor
M: 3-phase motor
*1.Also used as EDM input line.
*2.The functions are configurable with DIP Switch. Refer to
Safety Light Curtain F3SG-R Series User's Manual for more information on setting the functions by the DIP Switch.
M
F3SG-RA
Standalone F3SG-RA with Y-Joint Plug/Socket Connector using NPN outputs
The following is the example of External Device Monitoring enabled, Manual Reset mode, NPN output and External Test in 24 V Active.
DIP Switch settings *3
Receiver
Emitter
EDM Enabled
Manual Reset
Function
NPN
External Test: 24 V Active (factory default setting)
3
4
7
2
DIP-SW1
ON 2
DIP-SW2
ON
ON
ON
ON
3
4
7
ON
ON
ON
4 ON
: Indicates a switch position.
Configure functions with the DIP Switches before wiring.
Wiring Example
F39-JG
@B-L
F39-GCNY2
F39-JG
@A-D
S1
KM1 KM2
KM1
KM2
+24 VDC
Power supply
0 VDC
KM1
IN
KM2
PLC *2
S1: Lockout/Interlock Reset Switch
KM1,KM2: External device feedback
M: 3-phase motor
PLC: Programmable controller
(Used for monitoring only. NOT related to safety system.)
*1.Also used as EDM input line.
*2.When connecting to the PLC, the output mode must be changed with the Configuration Tool.
*3.The functions are configurable with DIP Switch. Refer to
Safety Light Curtain F3SG-R Series User's Manual for more information on setting the functions by the DIP Switch.
M
Beam state
Unblocked
Blocked
Reset Switch (S1)
OSSD
29
30
F3SG-RA
Standard Muting Mode/Exit-Only Muting Mode using NPN Outputs
The following is the example of External Device Monitoring enabled, Auto Reset mode, NPN output and External Test in 0 V Active.
DIP Switch settings *3
Receiver
Emitter
EDM Enabled
Function
Auto Reset (factory default setting)
NPN
External Test: 0 V Active
3
4
7
2
DIP-SW1
ON 2
DIP-SW2
ON
ON
ON
ON
3
4
7
ON
ON
ON
4 ON
: Indicates a switch position.
Configure functions with the DIP Switches before wiring.
Wiring Example
F39-JG
@A-L
F39-JG
@A-D
KM1
KM2
ML KM1 KM2
S1
S2
*2
S3
S4 S5
+24 VDC
Power Supply
0 VDC
M
KM1
KM2
S1: Test Switch (Connect the line to 24 V if this switch is not required)
S2: Override Cancel Switch
S3: Lockout/Interlock Reset Switch or Override Switch
S4, S5: Muting sensor
KM1, KM2: Safety relay with forcibly guided
contacts (G7SA) or magnetic contactor
M: 3-phase motor
ML: Muting lamp
*1.Also used as Override input line.
*2.Make sure to connect an override cancel switch to the Reset line when using the override function. Otherwise the override state may not be released by the override cancel switch, resulting in serious injury.
*3.The functions are configurable with DIP Switch. Refer to Safety
Light Curtain F3SG-R Series User's Manual for more information on setting the functions by the DIP Switch.
Beam state
Unblocked
Blocked
Test Switch (S1)
MUTE A
MUTE B
OSSD
F3SG-RA
Standard Muting Mode/Exit-Only Muting Mode with two Muting Sensors using NPN Outputs
The following is the example of External Device Monitoring enabled, Auto Reset mode, NPN output and External Test in 0 V Active.
DIP Switch settings *3
Receiver
Emitter
EDM Enabled
Function
Auto Reset (factory default setting)
NPN
External Test: 0 V Active
3
4
7
2
DIP-SW1
ON 2
DIP-SW2
ON
ON
ON
ON
3
4
7
ON
ON
ON
4 ON
: Indicates a switch position.
Configure functions with the DIP Switches before wiring.
Wiring Example
F39-JG
@A-L
F39-JG
@A-D
ML KM1 KM2
S1 S2
*2
S3
KM1
KM2
KM1
KM2
M
A1
Muting
Sensor
(NPN output)
B1
+24 VDC
Power Supply
0 VDC
Reflector
S1: Test Switch (Connect the line to 24 V if this switch is
not required)
S2: Override Cancel Switch
S3: Lockout/Interlock Reset Switch or Override Switch
KM1, KM2: Safety relay with forcibly guided contacts (G7SA)
or magnetic contactor
M: 3-phase motor
ML: Muting lamp
A1, B1: Muting sensor
Beam state
Unblocked
Blocked
Test Switch (S1)
*1.Also used as Override input line.
*2.Make sure to connect an override cancel switch to the Reset line when using the override function. Otherwise the override state may not be released by the override cancel switch, resulting in serious injury.
*3.The functions are configurable with DIP Switch. Refer to Safety
Light Curtain F3SG-R Series User's Manual for more information on setting the functions by the DIP Switch.
MUTE A
MUTE B
OSSD
31
F3SG-RA
Standard Muting Mode with four Muting Sensors using NPN Outputs
The following is the example of External Device Monitoring enabled, Auto Reset mode, NPN output and External Test in 0 V Active.
DIP Switch settings *3
Receiver
Emitter
EDM Enabled
Function
Auto Reset (factory default setting)
NPN
External Test: 0 V Active
3
4
7
2
DIP-SW1
ON 2
DIP-SW2
ON
ON
ON
ON
3
4
7
ON
ON
ON
4 ON
: Indicates a switch position.
Configure functions with the DIP Switches before wiring.
Wiring Example
F39-JG
@A-L
F39-JG
@A-D
32
ML
KM1 KM2
S1 S2
*2
S3
KM1
KM2
KM1
KM2
M
Reflector
B1
B2
+24 VDC
Power Supply
0 VDC
Muting
Sensor
(NPN output)
A1 A2
S1: Test Switch (Connect the line to 24 V if this switch is
not required)
S2: Override Cancel Switch
S3: Lockout/Interlock Reset Switch or Override Switch
KM1, KM2: Safety relay with forcibly guided contacts (G7SA)
or magnetic contactor
M: 3-phase motor
ML: Muting lamp
A1, A2, B1, B2: Muting sensor
*1.Also used as Override input line.
*2.Make sure to connect an override cancel switch to the Reset line when using the override function. Otherwise the override state maynot be released by the override cancel switch, resulting in serious injury.
*3.The functions are configurable with DIP Switch. Refer to Safety Light
Curtain F3SG-R Series User's Manual for more information on setting the functions by the DIP Switch.
Beam state
Unblocked
Blocked
Test Switch (S1)
MUTE A
MUTE B
OSSD
F3SG-RA
Pre-Resest Mode using NPN Output
The following is the example of External Device Monitoring enabled, Pre-Reset mode, NPN output and External Test in 0 V Active.
DIP Switch settings *2
Receiver
Emitter
EDM Enabled
Pre-Reset
Function
NPN
External Test: 0 V Active
3
4
7
2
DIP-SW1
ON 2
DIP-SW2
ON
ON
ON
ON
3
4
7
ON
ON
ON
4 ON
: Indicates a switch position.
Configure functions with the DIP Switches before wiring.
Wiring Example
F39-JG
@A-L
F39-JG
@A-D
KM1 KM2
S2 S3
S1
KM1
KM2
S1: Test Switch (Connect the line to 24 V if this switch is not
required)
S2: Lockout/Interlock Reset Switch
S3: Pre-Reset Switch
KM1, KM2: External device feedback
M: 3-phase motor
PLC: Programmable controller
(Used for monitoring only. NOT related to safety system.)
*1.When connecting to the PLC, the output mode must be changed with the Configuration Tool.
*2.The functions are configurable with DIP Switch. Refer to Safety
Light Curtain F3SG-R Series User's Manual for more information on setting the functions by the DIP Switch.
Pre-Reset Switch(S3)
IN
PLC *1
Beam state
Unblocked
Blocked
Reset Switch (S2)
OSSD
T1
T2
T3
T1: Push time: must be T1 >= 300ms
T2: Pre-reset limit time between Pre-reset and Reset: must be T2 <= 60s
T3: Push time: must be T3 >= 300ms
The F3SG-RA with NPN output can be connected to the safety control unit listed in the table below.
Connectable Safety Control Units (NPN output)
G9SA-301-P
+24 VDC
Power Supply
0 VDC
KM1
KM2
M
33
34
F3SG-RA
Input/Output Circuit
Entire Circuit Diagram
The entire circuit diagram of the F3SG-R is shown below.
The numbers in the circles indicate the connector's pin numbers.
PNP Output
Indicator
Emitter
Main Circuit
Test Input
Circuit
1
Brown
2
Black TEST
4
White Not used
5
Yellow Not used
3
Blue
+24 VDC
Receiver
Main Circuit 2
Receiver
Main Circuit 1
Indicator
Reset input circuit
Muting input circuit B
Muting input circuit A
2
Brown
1
Yellow RESET
4
Pink MUTE B
3
Gray MUTE A
6
White OSSD 2
5
Black OSSD 1
8
Red AUX
7
Blue
Load
Load
Load
0 VDC
NPN Output
Indicator
Emitter
Main Circuit
Test Input
Circuit
1
Brown
2
Black TEST
4
White Not used
5
Yellow Not used
3
Blue
+24 VDC
Receiver
Main Circuit 2
Reset input circuit
Muting input circuit B
Muting input circuit A
2
Brown
Yellow RESET
1
4
Pink MUTE B
3
Gray MUTE A
Load
6
White OSSD 2
Load
5
Black OSSD 1
Receiver
Main Circuit 1
Load
Indicator
8
Red AUX
7
Blue
0 VDC
Input Circuit Diagram by Function
The input circuit diagrams of by function are shown below.
PNP Output
<Input circuit (Test input)>
+24 VDC
5 V
Emitter
Main
Circuit
Short circuit current:
3 mA
0 VDC
NPN Output
<Input circuit (Test input)>
5 V
Emitter
Main
Circuit
<Input circuit (Reset input, Muting inputs A/B)>
+24 VDC
Short circuit current *
Receiver
Main
Circuit
0 VDC
<Input circuit (Reset, Muting inputs A/B)>
+24 VDC +24 VDC
Short circuit current:
3 mA
0 VDC
Receiver
Main
Circuit
Short circuit current *
0 VDC
*Short circuit current: 5mA (Reset input), 3mA (Muting inputs A/B)
F3SG-RA
35
36
F3SG-RA
Dimensions
Mounted with Standard Fixed Brackets (F39-LGF)
Backside Mounting
40
35 35
Standard
Fixed Bracket
(F39-LGF)
2-M5 or M6
Standard
Fixed Bracket
(F39-LGF)
9.2
24.85
2-M5 or M6
24.85
< Screw: M5 or M6 >
F3SG-
RA-30 Series
Dimension A
Dimension C1
Dimension D
Dimension P
C1+18
4-digit number of the type name
(Protective height)
C1-50
20
Protective height
(C1)
0190 to 1230
1310 to 2270
2350 to 2510
Number of Standard
Fixed Brackets
2
3
4
Dimension F
1000 mm max.
1000 mm max.
1000 mm max.
F3SG-
RA-14 Series
Dimension A
Dimension C2
Dimension D
Dimension P
C2+48
4-digit number of the type name
(Protective height)
C2-20
10
Protective height
(C2)
0160 to 1200
1280 to 2080
Number of Standard
Fixed Brackets
2
3
Dimension F
1000 mm max.
1000 mm max.
(Unit: mm)
F3SG-RA
Side Mounting
Standard
Fixed Bracket
(F39-LGF)
40
35 35
2-M5 or M6
Standard
Fixed Bracket
(F39-LGF)
9.2
42.35
2-M5 or M6
F3SG-
RA-30 Series
Dimension A
Dimension C1
Dimension D
Dimension P
C1+18
4-digit number of the type name
(Protective height)
C1-50
20
Protective height
(C1)
0190 to 1230
1310 to 2270
2350 to 2510
Number of Standard
Fixed Brackets
2
3
4
Dimension F
1000 mm max.
1000 mm max.
1000 mm max.
Standard Fixed Bracket (F39-LGF)
< Screw: M5 or M6 >
F3SG-
RA-14 Series
Dimension A
Dimension C2
Dimension D
Dimension P
C2+48
4-digit number of the type name
(Protective height)
C2-20
10
Protective height
(C2)
0160 to 1200
1280 to 2080
Number of Standard
Fixed Brackets
2
3
Dimension F
1000 mm max.
1000 mm max.
36
66
(25.8)
(23.1)
6.4
51
Material: ZDC2
37
38
F3SG-RA
Mounted with Standard Adjustable Brackets (F39-LGA)
Backside Mounting
35
Standard
Adjustable Bracket
(F39-LGA)
48.6
35
2-M5 or M6
Standard
Adjustable Bracket
(F39-LGA)
9.2
24.85
2-M5 or M6
24.85
< Screw: M5 or M6 >
F3SG-
RA-30 Series
Dimension A
Dimension C1
Dimension D
Dimension P
C1+18
4-digit number of the type name
(Protective height)
C1-50
20
Protective height
(C1)
0190 to 1230
1310 to 2270
2350 to 2510
Number of Standard
Adjustable Brackets
2
3
4
Dimension F
1000 mm max.
1000 mm max.
1000 mm max.
F3SG-
RA-14 Series
Dimension A
Dimension C2
Dimension D
Dimension P
C2+48
4-digit number of the type name
(Protective height)
C2-20
10
Protective height
(C2)
0160 to 1200
1280 to 2080
Number of Standard
Adjustable Brackets
2
3
Dimension F
1000 mm max.
1000 mm max.
F3SG-RA
Side Mounting
Standard
Adjustable Bracket
(F39-LGA)
48.6
35 35
2-M5 or M6
Standard
Adjustable Bracket
(F39-LGA)
9.2
42.35
2-M5 or M6
F3SG-
RA-30 Series
Dimension A
Dimension C1
Dimension D
Dimension P
C1+18
4-digit number of the type name
(Protective height)
C1-50
20
Protective height
(C1)
0190 to 1230
1310 to 2270
2350 to 2510
Number of Standard
Adjustable Brackets
2
3
4
Dimension F
1000 mm max.
1000 mm max.
1000 mm max.
Standard Adjustable Bracket (F39-LGA)
< Screw: M5 or M6 >
F3SG-
RA-14 Serie s
Dimension A
Dimension C2
Dimension D
Dimension P
C2+48
4-digit number of the type name
(Protective height)
C2-20
10
Protective height
(C2)
0160 to 1200
1280 to 2080
Number of Standard
Adjustable Brackets
2
3
Dimension F
1000 mm max.
1000 mm max.
42
45.1
84
(34.5)
(31.8)
6.4
72
Material: ZDC2 ,Fluorochemical lubricant oil
39
40
F3SG-RA
Mounted with Top/Bottom Adjustable Brackets (F39-LGTB) and Standard Adjustable Brackets (F39-LGA)
Dimensions when using the F3SG-RA Series except the F3SG-4RA0190-30 and F3SG-4RA0160-14
Refer to Safety Light Curtain F3SG-R Series User's Manual for the dimensions when using the F3SG-4RA0190-30 and F3SG-4RA0160-14.
Backside Mounting
Top/Bottom
Adjustable Bracket
(F39-LGTB)
2-S3
48.6
4
Backside : 2-S3
4
13.6
35
Standard Adjustable
Bracket
(F39-LGA)
26.5
23.2
35
40.8
35
S2.5
2-M5 or M6
2-M8
9.2
24.85
2-M5 or M6
24.85
2-M5 or M6
24.85
Top/Bottom
Adjustable Bracket
(F39-LGTB)
<Screw for Top/Bottom Adjustable
Bracket: M5 or M6>
<Screw for Top/Bottom Adjustable
Bracket: M8>
F3SG-
RA-30 Series
Dimension A
Dimension C1
Dimension D
Dimension G
Dimension H
Dimension I
Dimension P
C1+18
4-digit number of the type name
(Protective height)
C1-50
C1+77.5
C1+103
C1+122
20
Protective height
(C1)
0270 to 1070
1150 to 1950
2030 to 2510
Number of Top/Bottom
Adjustable Brackets
2
2
2
Number of Standard
Adjustable Brackets
0
1
2
Dimension F
−
1000 mm max.
1000 mm max.
F3SG-
RA-14 Serie s
Dimension A
Dimension C2
Dimension D
Dimension G
Dimension H
Dimension I
Dimension P
C2+48
4-digit number of the type name
(Protective height)
C2-20
C2+107.5
C2+133
C2+152
10
Protective height
(C2)
0240 to 1040
1120 to 1920
2000 to 2080
Number of Top/Bottom
Adjustable Brackets
2
2
2
Number of Standard
Adjustable Brackets
0
1
2
Dimension F
−
1000 mm max.
1000 mm max.
F3SG-RA
Side Mounting
2-S3
50.35
26.5
Top/Bottom
23.2
Adjustable Bracket
(F39-LGTB)
35
Backside : 2-S3
9.6
35
Standard
Adjustable Bracket
(F39-LGA)
S2.5
9.2
42.35
40.8
35
51.65
4
2-M5 or M6
2-M5 or M6
2-M8
2-M5 or M6
Top/Bottom
Adjustable Bracket
(F39-LGTB)
F3SG-
RA-30 Series
Dimension A
Dimension C1
Dimension D
Dimension G
Dimension H
Dimension I
Dimension P
C1+18
4-digit number of the type name
(Protective height)
C1-50
C1+77.5
C1+103
C1+122
20
Protective height
(C1)
0270 to 1070
1150 to 1950
2030 to 2510
Number of Top/Bottom
Adjustable Brackets
2
2
2
Number of Standard
Adjustable Brackets
0
1
2
Dimension F
−
1000 mm max.
1000 mm max.
<Screw for Top/Bottom Adjustable
Bracket: M5 or M6>
<Screw for Top/Bottom Adjustable
Bracket: M8>
F3SG-
RA-14 Serie s
Dimension A
Dimension C2
Dimension D
Dimension G
Dimension H
Dimension I
Dimension P
C2+48
4-digit number of the type name
(Protective height)
C2-20
C2+107.5
C2+133
C2+152
10
Protective height
(C2)
0240 to 1040
1120 to 1920
2000 to 2080
Number of Top/Bottom
Adjustable Brackets
2
2
2
Number of Standard
Adjustable Brackets
0
1
2
Dimension F
−
1000 mm max.
1000 mm max.
41
F3SG-RA
Top/Bottom Adjustable Bracket (F39-LGTB)
31
4
Top/Bottom
Bracket (1)
26
5
Top/Bottom
Bracket (2)
Top/Bottom
Bracket (3)
4
48.25
Screw(1)
23.2
26.5
20
Screw (2)
Accessories
Single-Ended Cable for Emitter (F39-JG
A-L, sold separately)
L
40.7
35
40.8
Material: SUS304
42
M12 IP67 connector
Insulated vinyl round cable dia. 6.6, 5-wire
(Cross section of conductor: 0.38 mm 2 /insulator diameter: dia. 1.2 mm)
Single-Ended Cable for Receiver (F39-JG
A-D, sold separately)
L
40.7
Emitter cable (Gray)
F39-JG3A-L
F39-JG7A-L
F39-JG10A-L
F39-JG15A-L
F39-JG20A-L
M12 IP67 connector
Insulated vinyl round cable dia. 6.6, 8-wire
(Cross section of conductor: 0.38 mm 2 /insulator diameter: dia. 1.2 mm)
Receiver cable (Black)
F39-JG3A-D
F39-JG7A-D
F39-JG10A-D
F39-JG15A-D
F39-JG20A-D
L (m)
3
7
10
15
20
F3SG-RA
Double-ended Cable for Emitter: Cable for extension (F39-JG
B-L, sold separately)
L
44.7
40.7
M12 IP67 connector
M12 IP67 connector
Insulated vinyl round cable dia. 6.6, 5-wire (2-pair + 1)
(Cross section of conductor: 0.38 mm 2 /insulator diameter: dia. 1.2 mm)
Double-Ended Cable for Receiver: Cable for extension (F39-JG
B-D, sold separately)
L
44.7
40.7
M12 IP67 connector
Emitter cable (Gray)
F39-JGR5B-L
F39-JG1B-L
F39-JG3B-L
F39-JG5B-L
F39-JG7B-L
F39-JG10B-L
F39-JG15B-L
F39-JG20B-L
M12 IP67 connector
Insulated vinyl round cable dia. 6.6, 8-wire (4-pair)
(Cross section of conductor: 0.38 mm 2 /insulator diameter: dia. 1.2 mm)
Receiver cable (Black)
F39-JGR15B-D
F39-JG1B-D
F39-JG3B-D
F39-JG5B-D
F39-JG7B-D
F39-JG10B-D
F39-JG15B-D
F39-JG20B-D
L (m)
0.5
1
3
5
7
10
15
20
Cascading Cable for Emitter (F39-JGR2W-L, sold separately)
200
M12 IP67 Connector
23.4
40.7
M2.5 screw
Connector
Insulated vinyl round cable dia. 6 mm, 5-wire
(Cross section of conductor: 0.15 mm 2 /Insulator diameter: dia. 1 mm)
Cascading Cable for Receiver (F39-JGR2W-D, sold separately
)
M12 IP67 Connector
200
23.4
40.7
M2.5 screw
Connector
Insulated vinyl round cable dia. 6 mm, 8-wire
(Cross section of conductor: 0.15 mm
2
/Insulator diameter: dia. 1 mm)
43
F3SG-RA
Y-Joint Plug/Socket Connector (F39-GCNY2, sold separately)
Plug marked with (bule circle): Connect to control panel side
Socket marked with (white circle): Connect to emitter
15.0
17.7
45.5
CN2
To control panel side
4.6 dia.
To emitter
CN1
500
Interface Unit (F39-GIF)
(625.7)
67.9
35.8
40.7
To receiver
M12 1
Material: PBT (Main body)
(46) (11.8)
(12) (16)
Insulated vinyl round cable 4.6 dia. Standard length: 0.5 m
300
54.4
5.4 dia.
23.3
17.5 dia.
30
10
58 2,000
4.6 dia.
17.5 dia.
14.5
7.7
11
Spatter Protection Cover (F39-HGA)
Assembled dimensions
40
Model
F39-HGA
@@@@
F39-HGA0550
Total length
@@@@+4
558
Material: PC (Transparent cover)
ABS (Side wall)
Stainless steel (Bracket)
Aluminum adhesive tape
(Fixing sticker)
Bluetooth unit (F39-BT)
35
30
35
35
Bluetooth + Lamp unit (F39-BTLP)
Lamp (F39-LP)
35
30
35
35
Material: PBT
44
Related Manuals
ManNo.
Z352
2.4
Model
F3SG-
@R@@@@@@@@
2.4
Material:
PC (Lighting element)
PBT (Other body parts)
Manual name
Safety Light Curtain F3SG-
@R Series User's Manual
Safety Light Curtain
Easy type
F3SG-RE
Easy-to-use Safety Sensor Ideal for
Simple On/Off Detection Applications
• Provides simple safety functions - saving TCO by reducing errors
• Simple wiring with only 4 wires
• Fast response time of 5 ms
Number of beams
79
87
95
103
111
119
127
135
47
55
63
71
15
23
31
39
143
151
159
167
175
183
191
199
207
Ordering Information
Main Units
Safety Light Curtain
Finger protection
Protective height
(mm)
800
880
960
1,040
1,120
1,200
1,280
1,360
160
240
320
400
480
560
640
720
1,440
1,520
1,600
1,680
1,760
1,840
1,920
2,000
2,080
PNP output
F3SG-4RE0160P14
F3SG-4RE0240P14
F3SG-4RE0320P14
F3SG-4RE0400P14
F3SG-4RE0480P14
F3SG-4RE0560P14
F3SG-4RE0640P14
F3SG-4RE0720P14
F3SG-4RE0800P14
F3SG-4RE0880P14
F3SG-4RE0960P14
F3SG-4RE1040P14
F3SG-4RE1120P14
F3SG-4RE1200P14
F3SG-4RE1280P14
F3SG-4RE1360P14
F3SG-4RE1440P14
F3SG-4RE1520P14
F3SG-4RE1600P14
F3SG-4RE1680P14
F3SG-4RE1760P14
F3SG-4RE1840P14
F3SG-4RE1920P14
F3SG-4RE2000P14
F3SG-4RE2080P14
Model
NPN output
F3SG-4RE0160N14
F3SG-4RE0240N14
F3SG-4RE0320N14
F3SG-4RE0400N14
F3SG-4RE0480N14
F3SG-4RE0560N14
F3SG-4RE0640N14
F3SG-4RE0720N14
F3SG-4RE0800N14
F3SG-4RE0880N14
F3SG-4RE0960N14
F3SG-4RE1040N14
F3SG-4RE1120N14
F3SG-4RE1200N14
F3SG-4RE1280N14
F3SG-4RE1360N14
F3SG-4RE1440N14
F3SG-4RE1520N14
F3SG-4RE1600N14
F3SG-4RE1680N14
F3SG-4RE1760N14
F3SG-4RE1840N14
F3SG-4RE1920N14
F3SG-4RE2000N14
F3SG-4RE2080N14
45
46
F3SG-RE
Number of beams
104
108
112
116
120
124
72
76
80
84
88
92
96
100
56
60
64
68
44
48
52
28
32
36
40
8
12
16
20
24
Hand and arm protection
Protective height
(mm)
1,470
1,550
1,630
1,710
1,790
1,870
1,950
2,030
2,110
2,190
2,270
2,350
2,430
2,510
910
990
1,070
1,150
1,230
1,310
1,390
190
270
350
430
510
590
670
750
830
PNP
F3SG-4RE0190P30
F3SG-4RE0270P30
F3SG-4RE0350P30
F3SG-4RE0430P30
F3SG-4RE0510P30
F3SG-4RE0590P30
F3SG-4RE0670P30
F3SG-4RE0750P30
F3SG-4RE0830P30
F3SG-4RE0910P30
F3SG-4RE0990P30
F3SG-4RE1070P30
F3SG-4RE1150P30
F3SG-4RE1230P30
F3SG-4RE1310P30
F3SG-4RE1390P30
F3SG-4RE1470P30
F3SG-4RE1550P30
F3SG-4RE1630P30
F3SG-4RE1710P30
F3SG-4RE1790P30
F3SG-4RE1870P30
F3SG-4RE1950P30
F3SG-4RE2030P30
F3SG-4RE2110P30
F3SG-4RE2190P30
F3SG-4RE2270P30
F3SG-4RE2350P30
F3SG-4RE2430P30
F3SG-4RE2510P30
Model
NPN
F3SG-4RE0190N30
F3SG-4RE0270N30
F3SG-4RE0350N30
F3SG-4RE0430N30
F3SG-4RE0510N30
F3SG-4RE0590N30
F3SG-4RE0670N30
F3SG-4RE0750N30
F3SG-4RE0830N30
F3SG-4RE0910N30
F3SG-4RE0990N30
F3SG-4RE1070N30
F3SG-4RE1150N30
F3SG-4RE1230N30
F3SG-4RE1310N30
F3SG-4RE1390N30
F3SG-4RE1470N30
F3SG-4RE1550N30
F3SG-4RE1630N30
F3SG-4RE1710N30
F3SG-4RE1790N30
F3SG-4RE1870N30
F3SG-4RE1950N30
F3SG-4RE2030N30
F3SG-4RE2110N30
F3SG-4RE2190N30
F3SG-4RE2270N30
F3SG-4RE2350N30
F3SG-4RE2430N30
F3SG-4RE2510N30
F3SG-RE
Accessories (Sold separately)
Single-ended Connector Cable (Round Water-resistant Connector: Connector Connected to Cable, Socket on One Cable End)
Appearance Type
M12 connector
(4-pin), 4 wires
Cable length
1 m
2 m
3 m
5 m
10 m
20 m
2
1
4
Female
3
Specifications
PIN
1
2
3
4
Emitter
+24 VDC
Range setting
0 VDC
Not used
Recelver
+24 VDC
OSSD 2
0 VDC
OSSD 1
Color
Brown
White
Blue
Black
Model
XS5F-D421-C80-F
XS5F-D421-D80-F
XS5F-D421-E80-F
XS5F-D421-G80-F
XS5F-D421-J80-F
XS5F-D421-L80-F
Double-ended Cable (Round Water-resistant Connector: Connectors Connected to Cable, Socket and Plug on Cable Ends)
For cable extension and simple wiring
Appearance Type Specifications
M12 connector
(4-pin) on both ends
Cable length
1 m
2 m
3 m
5 m
10 m
20 m
2
1
4
Female
3
1
2
3
4
Brown
White
Blue
Black
1
2
3
4
Brown
White
Blue
Black
2
1
3
Male
4
Model
XS5W-D421-C81-F
XS5W-D421-D81-F
XS5W-D421-E81-F
XS5W-D421-G81-F
XS5W-D421-J81-F
XS5W-D421-L81-F
Y-Joint Plug/Socket Connector for Easy type F3SG-RE
Appearance Type Cable length Specifications
F3SG-RE
Emitter
F3SG-RE
Receiver
Model
M12 connectors.
Used for reduced wiring.
0.5 m
Y-Joint Plug/
Socket Connector for Advance
F39-GCNY1
Double-ended Cable
XS5W-D421-
@81-F
Single-ended Connector
Cable
XS5F-D421-
@80-F
When using the reduced wiring connector system F39-GCNY1, the Operating Range Selection is fixed to Long Mode.
F39-GCNY1
Sensor Mounting Brackets
Appearance Specification
Standard
Fixed Bracket
Standard
Adjustable Bracket
Top/Bottom
Adjustable Bracket *2
Application
Bracket to mount the F3SG-R.
Side mounting and backside mounting possible.
(Included in the F3SG-R product package. See *1 below for the number of included brackets.)
Bracket to mount the F3SG-R.
Beam alignment after mounting possible.The angle adjustment range is
±15°.
Side mounting and backside mounting possible.
(Sold separately. See *1 below for the number of required brackets.)
Bracket to mount the F3SG-R. Use this bracket at the top and bottom positions of the F3SG-R.
Beam alignment after mounting possible.
The angle adjustment range is
±22.5°.
Side mounting and backside mounting possible.
(Sold separately. 4 brackets per set.)
Model
F39-LGF
F39-LGA
F39-LGTB
Top/Bottom
Adjustable Bracket *2
(For user-made mounting part)
Top/Bottom Adjustable Bracket without a bracket to mount to the wall. Use the user's own wall mounting part to suit the machine.
(Sold separately. 4 brackets per set.)
F39-LGTB-1
*1 Two brackets per set
[for F3SG-
@RE@@@@@14] Protective height of 0160 to 1200: 2 sets, Protective height of 1280 to 2080: 3 sets
[for F3SG-
@RE@@@@@30] Protective height of 0190 to 1230: 2 sets, Protective height of 1310 to 2270: 3 sets, Protective height of 2350 to 2510: 4 sets
*2 Top/Bottom Adjustable Bracket cannot be used with the Standard Fixed Bracket. Use with the Standard Adjustable Bracket.
(See *1 for the number of required brackets.)
Laser Pointer for F3SG-R
Appearance Specifications Model
The laser pointer is attached on the optical surface of the F3SG to help coarse adjustment of beams.
F39-PTG
47
F3SG-RE
48
Spatter Protection Cover (Two covers per set, for emitter and receiver)
Spatter Protection Covers include mounting brackets.
For Safety Light Curtain models of the protective height of 2,000 mm or longer, use two Spatter Protection Covers of different lengths.
Appearance
Safety Light Curtain Model
Finger protection
F3SG-
@RE0160@14
F3SG-
@RE0240@14
F3SG-
@RE0320@14
F3SG-
@RE0400@14
F3SG-
@RE0480@14
F3SG-
@RE0560@14
F3SG-
@RE0640@14
F3SG-
@RE0720@14
F3SG-
@RE0800@14
F3SG-
@RE0880@14
F3SG-
@RE0960@14
F3SG-
@RE1040@14
F3SG-
@RE1120@14
F3SG-
@RE1200@14
F3SG-
@RE1280@14
F3SG-
@RE1360@14
F3SG-
@RE1440@14
F3SG-
@RE1520@14
F3SG-
@RE1600@14
F3SG-
@RE1680@14
F3SG-
@RE1760@14
F3SG-
@RE1840@14
F3SG-
@RE1920@14
Hand and arm protection
F3SG-
@RE0190@30
F3SG-
@RE0270@30
F3SG-
@RE0350@30
F3SG-
@RE0430@30
F3SG-
@RE0510@30
F3SG-
@RE0590@30
F3SG-
@RE0670@30
F3SG-
@RE0750@30
F3SG-
@RE0830@30
F3SG-
@RE0910@30
F3SG-
@RE0990@30
F3SG-
@RE1070@30
F3SG-
@RE1150@30
F3SG-
@RE1230@30
F3SG-
@RE1310@30
F3SG-
@RE1390@30
F3SG-
@RE1470@30
F3SG-
@RE1550@30
F3SG-
@RE1630@30
F3SG-
@RE1710@30
F3SG-
@RE1790@30
F3SG-
@RE1870@30
F3SG-
@RE1950@30
F3SG-
@RE2000@14
F3SG-
@RE2080@14
−
−
−
−
−
F3SG-
@RE2030@30
F3SG-
@RE2110@30
F3SG-
@RE2190@30
F3SG-
@RE2270@30
F3SG-
@RE2350@30
F3SG-
@RE2430@30
F3SG-
@RE2510@30
Model
F39-HGB0180
F39-HGB0260
F39-HGB0340
F39-HGB0420
F39-HGB0500
F39-HGB0580
F39-HGB0660
F39-HGB0740
F39-HGB0820
F39-HGB0900
F39-HGB0980
F39-HGB1060
F39-HGB1140
F39-HGB1220
F39-HGB1300
F39-HGB1380
F39-HGB1460
F39-HGB1540
F39-HGB1620
F39-HGB1700
F39-HGB1780
F39-HGB1860
F39-HGB1940
F39-HGB1460
F39-HGA0550
F39-HGB1540
F39-HGA0550
F39-HGB1620
F39-HGA0550
F39-HGB1700
F39-HGA0550
F39-HGB1780
F39-HGA0550
F39-HGB1860
F39-HGA0550
F39-HGB1940
F39-HGA0550
Note: The operating range of the Safety Light Curtain attached with the product is 10% shorter than the rating.
Test Rod
Diameter
14 mm dia.
30 mm dia.
Model
F39-TRD14
F39-TRD30
Ratings/Specifications
Main unit
Performance
Type of ESPE
(IEC 61496-1)
Type 4
Type 2
Object Resolution
(Detection Capability)
Beam Gap
Number of Beams
Lens Size
Protective Height
Operating Range
Long
Short
ON to OFF
OFF to ON
F3SG-4RE
@@@@-14, F3SG-2RE@@@@-14
F3SG-4RE
@@@@@14/30
F3SG-2RE
@@@@@14/30
Opaque objects
14-mm dia.
10mm
15 to 207
5.2
×3.4 (W×H) mm
160 to 2080 mm (6.3 to81.9 inch)
0.3 to 10.0 m (1 to 32 ft.)
0.3 to 3.0 m (1 to 10 ft.)
5 to 15ms *1
25 to 75ms *1
F3SG-4RE
@@@@-30, F3SG-2RE@@@@-30
30-mm dia.
20mm
8 to 124
7-mm dia.
190 to 2510 mm (7.3 to98.7 inch)
0.3 to 20.0 m (1 to 65 ft.)
0.3 to 7.0 m (1 to 23 ft.)
Response Time
*1.Response time when used in one segment system or in cascaded connection
Refer to page 50 .
Type 4
±2.5° max., emitter and receiver at operating range of 3 m or greater
Effective Aperture
Angle (EAA)
(IEC61496-2)
Type 2
Light Source
Startup Waiting Time
±5.0° max., emitter and receiver at operating range of 3 m or greater
Infrared LEDs, Wavelength: 870 nm
2 s max.
F3SG-RE
Electricall
Power Supply Voltage (Vs)
Current Consumption
Safety Outputs (OSSD)
Output Operation
Mode
Input Voltage
F3SG-4RE
@@@@-14, F3SG-2RE@@@@-14
SELV/PELV 24 VDC
±20% (ripple p-p 10% max.)
Refer to page 50
F3SG-
@RE@@@@P@@: Two PNP transistor outputs
F3SG-
@RE@@@@N@@: Two NPN transistor outputs
F3SG-4RE
@@@@-30, F3SG-2RE@@@@-30
Load current of 300 mA max., Residual voltage of 2 V max. (except for voltage drop due to cable extension), Capacitive load of 1
μF max., Inductive load of 2.2 H max. *1
Leakage current of 1 mA max. (PNP), 2 mA max. (NPN) *2
*1
.The load inductance is the maximum value when the safety output frequently repeats ON and OFF.
When you use the safety output at 4 Hz or less, the usable load inductance becomes larger.
*2.
These values must be taken into consideration when connecting elements including a capacitive
load such as a capacitor.
Safety
Output
Light-ON (Safety output is enabled when the receiver receives an emitting signal.)
ON Voltage
Operating Range Select Input:
Long: 9 V to Vs (sink current 3 mA max.) *
OFF Voltage
Short: 0 to 3 V (source current 3 mA max.)
*The Vs indicates a supply voltage value in your environment.
Overvoltage Category (IEC60664-1)
Indicators
Protective Circuit
Insulation Resistance
II
Refer to page 51
Output short protection, Power supply reverse polarity protection
20 M
Ω or higher (500 VDC megger)
1,000 VAC, 50/60 Hz (1 min)
Environmental
Dielectric Strength
Functional Test Function
Ambient
Temperature
Ambient
Humidity
Operating
Storage
Operating
Storage
Self-test (at power-on, and during operation)
-10 to 55
°C (14 to 131°F) (non-icing)
-25 to 70
°C (-13 to 158°F)
35% to 85% (non-condensing)
35% to 95%
Ambient Illuminance
Incandescent lamp: 3,000 Ix max. on receiver surface
Sunlight: 10,000 Ix max. on receiver surface
IP65 and IP67
Degree of Protection (IEC 60529)
Vibration Resistance (IEC 61496-1)
10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps for all 3 axes
Shock Resistance (IEC 61496-1) 100 m/s
2
, 1000 shocks for all 3 axes
Pollution Degree (IEC 60664-1)
Pollution Degree 3
Type of Connection
M12 connectors: 4-pin, IP67 rated when mated,Cables prewired to the sensors
Power cable
Number of Wires
Cable Length
Cable Diameter
Emitter: 4, Receiver: 4
0.3 m
6 mm
Connections
Minimum Bending Radius
Type of Connection
Number of Wires
Extension cable
- Single-ended cable
- Double-ended cable
Cable Length
Cable Diameter
Minimum Bending Radius
Extension of Power Cable
R5 mm
Use the XS5
100 m max.
@-D42@ series cables.
Material
Material
Weight (packaged)
Included Accessories
Housing: Aluminum
Cap: PBT
Front window: PMMA
Cable: Oil resistant PVC
Mounting Bracket: ZDC2
FE plate: SUS
Refer to
page 50.
Safety Precautions, Quick Installation Manual, Standard Fixed Bracket*1, Troubleshooting Guide
Sticker
*1. The quantity of Standard Fixed Brackets included varies depending on the protective height.
[F3SG-
@RE@@@@@14]
- Protective height of 0160 to 1200: 2 sets
- Protective height of 1280 to 2080: 3 sets
[F3SG-
@RE@@@@@30]
- Protective height of 0190 to 1230: 2 sets
- Protective height of 1310 to 2270: 3 sets
- Protective height of 2350 to 2510: 4 sets
Refer to
page 19
PL e/Category 4 (EN ISO 13849-1:2008)
Conformity
Conforming standards
Performance Level
(PL)/Safety category
Type 4
Type 2
PFHd
Proof test interval T
M
SFF
HFT
Classification
PL c/Category 2 (EN ISO 13849-1:2008)
9.1
× 10
-9
(IEC 61508)
Every 20 years (IEC 61508)
99% (IEC 61508)
1 (IEC 61508)
Type B (IEC 61508-2)
49
50
F3SG-RE
List of Models/Response Time/Current Consumption/Weight
F3SG-
@RE@@@@@-14
Model
F3SG-
@RE0160@14
F3SG-
@RE0240@14
F3SG-
@RE0320@14
F3SG-
@RE0400@14
F3SG-
@RE0480@14
F3SG-
@RE0560@14
F3SG-
@RE0640@14
F3SG-
@RE0720@14
F3SG-
@RE0800@14
F3SG-
@RE0880@14
F3SG-
@RE0960@14
F3SG-
@RE1040@14
F3SG-
@RE1120@14
F3SG-
@RE1200@14
F3SG-
@RE1280@14
F3SG-
@RE1360@14
F3SG-
@RE1440@14
F3SG-
@RE1520@14
F3SG-
@RE1600@14
F3SG-
@RE1680@14
F3SG-
@RE1760@14
F3SG-
@RE1840@14
F3SG-
@RE1920@14
F3SG-
@RE2000@14
F3SG-
@RE2080@14
Number of
Beams
Protective
Height
[mm]
1200
1280
1360
1440
1520
1600
1680
1760
1840
1920
2000
2080
560
640
720
800
880
960
1040
1120
160
240
320
400
480
151
159
167
175
119
127
135
143
183
191
199
207
87
95
103
111
55
63
71
79
15
23
31
39
47
13
13
13
13
11
11
11
11
13
15
15
15
9
9
9
11
7
7
9
9
7
7
7
5
5
ON
→OFF
Response Time[ms]
OFF
(Synchronized)
→ON
25
OFF (Not synchronized)
→ON
125
25
35
35
35
125
135
135
135
45
45
45
55
35
35
45
45
135
135
145
145
145
145
145
155
65
65
65
65
55
55
55
55
65
75
75
75
165
165
165
165
155
155
155
155
165
175
175
175
* The weight includes an emitter, a receiver and included brackets in a product package.
Current Consumption[mA]
Emitter Receiver
95
100
105
110
100
105
110
115
115
110
115
115
90
95
100
90
80
85
80
85
45
55
55
65
70
90
90
95
95
80
80
85
85
95
100
100
105
70
75
75
75
60
65
65
70
50
55
55
60
60
F3SG-
@RE@@@@@30
Model
Number of
Beams
Protective
Height
[mm]
ON
→OFF
Response Time[ms]
OFF
(Synchronized)
→ON
F3SG-
@RE0190@30
F3SG-
@RE0270@30
F3SG-
@RE0350@30
F3SG-
@RE0430@30
F3SG-
@RE0510@30
F3SG-
@RE0590@30
F3SG-
@RE0670@30
F3SG-
@RE0750@30
F3SG-
@RE0830@30
F3SG-
@RE0910@30
F3SG-
@RE0990@30
F3SG-
@RE1070@30
F3SG-
@RE1150@30
F3SG-
@RE1230@30
F3SG-
@RE1310@30
F3SG-
@RE1390@30
F3SG-
@RE1470@30
F3SG-
@RE1550@30
F3SG-
@RE1630@30
F3SG-
@RE1710@30
F3SG-
@RE1790@30
F3SG-
@RE1870@30
F3SG-
@RE1950@30
F3SG-
@RE2030@30
F3SG-
@RE2110@30
F3SG-
@RE2190@30
F3SG-
@RE2270@30
F3SG-
@RE2350@30
F3SG-
@RE2430@30
F3SG-
@RE2510@30
8
12
16
20
24
28
32
36
40
44
48
52
56
60
64
68
72
76
80
84
88
92
96
100
104
108
112
116
120
124
190
270
350
430
510
590
670
750
830
910
990
1070
1150
1230
1310
1390
1470
1550
1630
1710
1790
1870
1950
2030
2110
2190
2270
2350
2430
2510
5
5
5
5
5
7
7
7
7
7
7
7
7
7
7
9
9
9
9
9
9
9
9
9
9
11
11
11
11
11
25
25
25
25
25
35
35
35
35
35
35
35
35
35
35
45
45
45
45
45
45
45
45
45
45
55
55
55
55
55
* The weight includes an emitter, a receiver and included brackets in a product package.
OFF (Not synchronized)
→ON
125
125
125
125
125
135
135
135
135
135
135
135
135
135
135
145
145
145
145
145
145
145
145
145
145
155
155
155
155
155
Current Consumption[mA]
Emitter Receiver
100
100
90
95
95
95
100
85
90
95
95
75
80
80
85
75
80
85
85
60
65
65
70
55
60
50
55
40
45
50
80
80
80
75
75
75
80
70
70
75
75
65
65
70
70
60
65
65
65
60
60
60
60
55
55
55
55
50
50
50
Weight
[kg] *
5.9
6.5
6.7
6.9
4.9
5.1
5.6
5.7
7.1
7.3
7.4
8.0
4.2
4.4
4.6
4.7
3.1
3.3
3.8
4.0
1.7
1.9
2.1
2.6
2.8
Weight
[kg] *
7.3
7.9
8.1
8.2
8.7
8.8
9.0
6.6
6.8
7.0
7.2
5.5
5.7
5.9
6.4
4.5
4.7
4.9
5.1
3.8
4.0
4.2
4.4
1.7
1.9
2.1
2.6
2.8
3.0
3.2
F3SG-RE
LED Indicator Status
Emitter
Name of Indicator
Operating range
Power
Lockout
LONG
POWER
LOCKOUT
Color Illuminated
Green Long range mode is selected
Green
Power is ON.
Red
−
Receiver
Name of Indicator
Top-beam-state TOP
Internal error
Lockout
INTERNAL
LOCKOUT
Color Illuminated
Blue The top beam is unblocked
Red
Red
−
−
Stable-state STB
ON/OFF ON/OFF
Communication COM
Bottom-beam-state BTM
Green Incident light level is 170% or higher of ON threshold
Green
Safety output is in ON state
Red
Safety output is in OFF state
Green
Synchronization between emitter and receiver is maintained
Blue The bottom beam is unblocked
Blinking
Lockout state due to Operating range selection setting error
Error due to noise
Lockout state due to error in emitter
Blinking
−
Lockout state due to Internal error, or error due to abnormal power supply or noise
Lockout state due to error in receiver
Safety output is instantaneously turned OFF due to ambient light or vibration
−
Lockout state due to Safety Output error, or error due to abnormal power supply or noise
Lockout state due to Communication error, or error due to abnormal power supply or noise
−
51
F3SG-RE
Connections (Basic Wiring Diagram)
Short Mode
Long Mode
+24 V
DC
Power
Supply
0 V
Functional Earth
IN1 IN2
Safety
Controller *1*2
*1.Refer to page 49 for more information.
*2.The safety controller and the F3SG-R must share the power supply or be connected to the common terminal of the power supply.
Beam state
Unblocked
Blocked
OSSD
52
+24 V
DC
Power
Supply
0 V
IN1 IN2
Safety
Controller *1*2
*1.Refer to page 49 for more information.
*2.The safety controller and the F3SG-R must share the power supply or be connected to the common terminal of the power supply.
Beam state
Unblocked
Blocked
OSSD
F3SG-RE
Standalone F3SG-RE with Y-Joint Plug/Socket Connector
F39-GCNY1
XS5W-D42 - 81-
XS5F-D42 - 80-
+24V DC
Power supply
0V
IN1 IN2
Safety
Controller *1*2
*1.Refer to the following list "Connectable Safety Control Units" on this page.
*2.The safety controller and the F3SG-R must share the power supply or be connected to the common terminal of the power supply.
Beam state
Unblocked
Blocked
OSSD
Note: When using the reduced wiring connector system F39-GCNY1, the Operating Range Selection is fixed to Long Mode.
Connectable Safety Control Units
The F3SG-RE with PNP output can be connected to the safety control units listed in the table below.
Connectable Safety Control Units (PNP output)
G9SA-301
G9SA-321
G9SA-501
G9SB-200-B
G9SB-200-D
G9SB-301-B
G9SB-301-D
G9SE-201
G9SE-401
G9SE-221-T
@
G9SX-AD322-T
G9SX-ADA222-T
G9SX-BC202
G9SX-GS226-T15
G9SP-N10S
G9SP-N10D
G9SP-N20S
NE0A-SCPU01
NE1A-SCPU01
NE1A-SCPU02
DST1-ID12SL-1
DST1-MD16SL-1
DST1-MRD08SL-1
NX-SIH400
NX-SID800
F3SP-T01
53
54
F3SG-RE
Input/Output Circuit
PNP Output
Indicator
Emitter
Main Circuit
1
Brown
Operating Range
Select Input circuit
2
White
Operating Range
Select Input
4
Black Not connected
+24 V
Receiver
Main Circuit 2
3
Blue
1
Brown
2
White OSSD 2
Load
4
Black OSSD 1
Receiver
Main Circuit 1
Indicator
Load
3
Blue
0 V
NPN Output
Indicator
Emitter
Main Circuit
Operating Range
Select Input circuit
1
Brown
2
White
Operating Range
Select Input
4
Black Not connected
+24 V
3
Blue
Receiver
Main Circuit 2
1
Brown
2
White OSSD 2
Load
Load
4
Black OSSD 1
Receiver
Main Circuit 1
Indicator
3
Blue
0 V
Input Circuit Diagram by Function
The input circuit diagrams of by function are shown below.
PNP Output
<Input circuit (Operating Range Select Input)>
+24 VDC
5 V
Emitter
Main
Circuit
Short circuit current:
3 mA
0 VDC
NPN Output
<Input circuit (Operating Range Select Input)>
5 V
Emitter
Main
Circuit
+24 VDC
Short circuit current:
3 mA
0 VDC
F3SG-RE
55
56
F3SG-RE
Dimensions
Mounted with Standard Fixed Brackets (F39-LGF)
Backside Mounting
35
40
35
Standard Fixed
Bracket
(F39-LGF)
2-M5 or M6
Standard Fixed
Bracket
(F39-LGF)
9.2
24.85
2-M5 or M6
24.85
< Screw: M5 or M6 >
F3SG-4RE
@@@@@30 Series
Dimension A
Dimension C1
Dimension D
Dimension P
C1
4-digit number of the type name(Protective height)
C1-50
20
Protective height
(C1)
0190 to 1230
1310 to 2270
2350 to 2510
Number of Standard
Fixed Brackets
2
3
4
Dimension F
1000 mm max.
1000 mm max.
1000 mm max.
F3SG-4RE
@@@@@14 Series
Dimension A
Dimension C2
Dimension D
Dimension P
C2+30
4-digit number of the type name(Protective height)
C2-20
10
Protective height
(C2)
0160 to 1200
1280 to 2080
Number of Standard
Fixed Brackets
2
3
Dimension F
1000 mm max.
1000 mm max.
(Unit: mm)
F3SG-RE
Side Mounting
Standard Fixed
Bracket
(F39-LGF)
40
35
35
2-M5 or M6
Standard Fixed
Bracket
(F39-LGF)
9.2
42.35
2-M5 or M6
< Screw: M5 or M6 >
F3SG-4RE
@@@@@30 Series
Dimension A
Dimension C1
Dimension D
Dimension P
C1
4-digit number of the type name (Protective height)
C1-50
20
Protective height
(C1)
0190 to 1230
1310 to 2270
2350 to 2510
Number of Standard
Fixed Brackets
2
3
4
Dimension F
1000 mm max.
1000 mm max.
1000 mm max.
Standard Fixed Bracket(F39-LGF)
F3SG-4RE
@@@@@14 Series
Dimension A
Dimension C2
Dimension D
Dimension P
C2+30
4-digit number of the type name (Protective height)
C2-20
10
Protective height
(C2)
0160 to 1200
1280 to 2080
Number of Standard
Fixed Brackets
2
3
Dimension F
1000 mm max.
1000 mm max.
36
66
(25.8)
(23.1)
6.4
51
Material: ZDC2
57
58
F3SG-RE
Mounted with Standard Fixed Brackets (F39-LGA)
Backside Mounting
48.6
35
35
Standard Adjustable
Bracket
(F39-LGA)
2-M5 or M6
Standard Adjustable
Bracket
(F39-LGA)
9.2
24.85
2-M5 or M6
24.85
< Screw: M5 or M6 >
F3SG-4RE
@@@@@30 Series
Dimension A
Dimension C1
Dimension D
Dimension P
C1
4-digit number of the type name (Protective height)
C1-50
20
Protective height
(C1)
0190 to 1230
1310 to 2270
2350 to 2510
Number of Standard
Adjustable Brackets
2
3
4
Dimension F
1000 mm max.
1000 mm max.
1000 mm max.
F3SG-4RE
@@@@@14 Series
Dimension A
Dimension C2
Dimension D
Dimension P
C2+30
4-digit number of the type name (Protective height)
C2-20
10
Protective height
(C2)
0160 to 1200
1280 to 2080
Number of Standard
Adjustable Brackets
2
3
Dimension F
1000 mm max.
1000 mm max.
F3SG-RE
Side Mounting
Standard Adjustable
Bracket
(F39-LGA)
48.6
35
35
2-M5 or M6
Standard Adjustable
Bracket
(F39-LGA)
9.2
42.35
2-M5 or M6
F3SG-4RE
@@@@@30 Series
Dimension A
Dimension C1
Dimension D
Dimension P
C1
4-digit number of the type name (Protective height)
C1-50
20
Protective height
(C1)
0190 to 1230
1310 to 2270
2350 to 2510
Number of Standard
Adjustable Brackets
2
3
4
Standard Fixed Bracket (F39-LGA)
Dimension F
1000 mm max.
1000 mm max.
1000 mm max.
< Screw: M5 or M6 >
F3SG-4RE
@@@@@14 Series
Dimension A
Dimension C2
Dimension D
Dimension P
C2+30
4-digit number of the type name (Protective height)
C2-20
10
Protective height
(C2)
0160 to 1200
1280 to 2080
Number of Standard
Adjustable Brackets
2
3
Dimension F
1000 mm max.
1000 mm max.
42
45.1
84
(34.5)
(31.8)
6.4
72
Material: ZDC2, Fluorochemical lubricant oil
59
60
F3SG-RE
Mounted with Top/Bottom Adjustable Brackets (F39-LGTB) and Standard Adjustable Brackets (F39-LGA)
Dimensions when using the F3SG-RE Series except the F3SG-4RE0190
@30 and F3SG-4RE0160@14
Refer to Safety Light Curtain F3SG-R Series User's Manual for the dimensions when using the F3SG-4RE0190
@30 and F3SG-4RE0160@14.
Backside Mounting
2-S3
Top/Bottom
Adjustable Bracket
(F39-LGTB)
4
48.6
Backside : 2-S3
4
13.6
35
26.5
23.2
35
40.8
35
2-M5 or M6
2-M8
Standard
Adjustable Bracket
(F39-LGA)
S2.5
9.2
24.85
2-M5 or M6
24.85
2-M5 or M6
24.85
Top/Bottom
Adjustable Bracket
(F39-LGTB)
F3SG-4RE
@@@@@30 Series
Dimension A
Dimension C1
Dimension D
Dimension G
Dimension H
Dimension I
Dimension P
C1
4-digit number of the type name (Protective height)
C1-50
C1+43.5
C1+69
C1+88
20
Protective height
(C1)
0270 to 1070
1150 to 1950
2030 to 2510
Number of Top/Bottom
Adjustable Brackets
2
2
2
Number of Standard
Adjustable Brackets
0
1
2
Dimension F
−
1000 mm max.
1000 mm max.
<Screw for Top/Bottom Adjustable
Bracket: M5 or M6>
<Screw for Top/Bottom Adjustab
Bracket: M8>
F3SG-4RE
@@@@@14 Series
Dimension A
Dimension C2
Dimension D
Dimension G
Dimension H
Dimension I
Dimension P
C2+30
4-digit number of the type name (Protective height)
C2-20
C2+73.5
C2+99
C2+118
10
Protective height
(C2)
0240 to 1040
1120 to 1920
2000 to 2080
Number of Top/Bottom
Adjustable Brackets
2
2
2
Number of Standard
Adjustable Brackets
0
1
2
Dimension F
−
1000 mm max.
1000 mm max.
F3SG-RE
Side Mounting
2-S3
50.35
Top/Bottom
Adjustable Bracket
(F39-LGTB)
26.5
23.2
35
Backside : 2-S3
Standard
Adjustable Bracket
(F39-LGA)
S2.5
9.2
42.35
35
Top/Bottom
Adjustable Bracket
(F39-LGTB)
40.8
35
51.65
4
2-M5 or M6
2-M5 or M6
2-M8
2-M5 or M6
F3SG-4RE
@@@@@30 Series
Dimension A
Dimension C1
Dimension D
Dimension G
Dimension H
Dimension I
Dimension P
C1
4-digit number of the type name (Protective height)
C1-50
C1+43.5
C1+69
C1+88
20
Protective height
(C1)
0270 to 1070
1150 to 1950
2030 to 2510
Number of Top/Bottom
Adjustable Brackets
2
2
2
Number of Standard
Adjustable Brackets
0
1
2
Dimension F
−
1000 mm max.
1000 mm max.
Top/Bottom Adjustable Bracket
(F39-LGTB)
4
31
Top/Bottom
Bracket (1)
<Screw for Top/Bottom Adjustable
Bracket: M5 or M6>
F3SG-4RE
@@@@@14 Series
Dimension A
Dimension C2
Dimension D
Dimension G
Dimension H
Dimension I
Dimension P
<Screw for Top/Bottom
Adjustable Bracket: M8>
C2+30
4-digit number of the type name (Protective height)
C2-20
C2+73.5
C2+99
C2+118
10
Protective height
(C2)
0240 to 1040
1120 to 1920
2000 to 2080
Number of Top/Bottom
Adjustable Brackets
2
2
2
Number of Standard
Adjustable Brackets
0
1
2
Dimension F
−
1000 mm max.
1000 mm max.
26
Screw (2)
Top/Bottom
Bracket (2)
5
20
Top/Bottom
Bracket (3)
4
48.25
Screw(1)
23.2
26.5
Material: SUS304
35
40.8
61
62
F3SG-RE
Accessories
Round Water-resistant Connector: Connector Connected to Cable, Socket on One Cable End
(XS5F-D421-
@80-F, sold separately)
L (Cable length)
40.7
6 dia.
14.9 dia.
M12
30 5
50
Material: Insulated vinyl round cable
Specification
Fire-retardant, Robot cable
Model
XS5F-D421-C80-F
XS5F-D421-D80-F
XS5F-D421-E80-F
XS5F-D421-G80-F
XS5F-D421-J80-F
XS5F-D421-L80-F
L (m)
1
2
3
5
10
20
Round Water-resistant Connector: Connectors Connected to Cable, Socket and Plug on Cable Ends
(XS5W-D421-
@81-F, sold separately)
M12
6 dia.
40.7
44.7
Specification
L (Cable length)
Fire-retardant, Robot cable
Model
XS5W-D421-C81-F
XS5W-D421-D81-F
XS5W-D421-E81-F
XS5W-D421-G81-F
XS5W-D421-J81-F
XS5W-D421-L81-F
L (m)
1
2
10
20
3
5
Y-Joint Plug/Socket Connector (F39-GCNY1, sold separately)
15.0
Plug marked with (bule circle): Connect to control panel side
Socket marked with (white circle): Connect to emitter
17.7
45.5
CN2
To control panel side
4.6 dia.
To emitter
CN1
500
Spatter Protection Cover(F39-HGA/-HGB)
Assembled dimensions
40
Model
F39-HGB
@@@@
F39-HGA0550
Total length
@@@@+6
558
Material: PC (Transparent cover)
ABS (Side wall)
Stainless steel (Bracket)
Aluminum adhesive tape
(Fixing sticker)
Related Manuals
ManNo.
Z352
Model
F3SG-
@R@@@@@@@@
Material: Insulated vinyl round cable
40.7
To receiver
M12 1
Material: PBT (Main body)
Manual name
Safety Light Curtain
F3SG-
@R Series User's Manual
Smart Muting Actuator
F3W-MA
Integrated muting sensor based on multi-beam photoelectric sensor
• A muting system can be configured easily in combination with the safety light curtain.
• Muting functions can be stably performed even when workpieces with holes pass.
Ordering Information
Smart Muting Actuator
Appearance
Beam Gap between Muting Trigger
Beams
100 mm
output
Number of
Beams
8
PNP output
300 mm 20
Note: Use with the PNP output model safety light curtain.
Accessories (Sold separately)
Single-ended Connector Cable
Appearance Type
M12 connector
(5-pin), 5 wires
Color: Gray
For receiver
M12 connector
(8-pin), 8 wires
Color: Black
Cable length
3 m
7 m
10 m
15 m
20 m
3 m
7 m
10 m
15 m
20 m
Double-en1ded Cable
Appearance Type
M12 connector
(5-pin) on both ends
Color: Gray
M12 connector
(8-pin) on both ends
Color: Black
1 m
3 m
5 m
7 m
10 m
15 m
20 m
Cable length
0.5 m
1 m
3 m
5 m
7 m
10 m
15 m
20 m
0.5 m
1
4
5
2
3
Female
7
6
1
8
5
2
4
3
Female
Connected to Power Cable or Double-Ended Cable
1
4
5
2
3
2
4
5
1
3
Female
Brown
Blue
Black
White
Yellow
Connected to Power Cable or Double-Ended Cable
7
6
1
8
5
2
4
3
Female
3
4
1
8
5
6
2
7
Brown
Blue
Black
White
Yellow
Red
Gray
Pink
Specifications
3
4
5
1
2
+24 VDC
CFG In
0 VDC
COM+
COM-
Brown
Black
Blue
White
Yellow
1
2
Mute Enable / CFG In / Reset
+24 VDC
Yellow
Brown
3 COM+ Gray
4
COMPink
5 Muting Output A Black
6
7
Muting Output B
0 VDC
8 CFG Out
White
Blue
Red
Specifications
Connected to Single-Ended Cable,
Double-Ended cable
2
4
5
1
3
Brown
Blue
Black
White
Yellow
2
3
5
Male
1
4
Connected to Single-Ended Cable,
Double-Ended cable
3
4
1
8
5
6
2
7
Brown
Blue
Black
White
Yellow
Red
Gray
Pink
3
4
2
8
5
1
6
7
Male
Model
F3W-MA0100P
F3W-MA0300P
Model
F39-JG3A-L
F39-JG7A-L
F39-JG10A-L
F39-JG15A-L
F39-JG20A-L
F39-JG3A-D
F39-JG7A-D
F39-JG10A-D
F39-JG15A-D
F39-JG20A-D
Model
F39-JGR5B-L
F39-JG1B-L
F39-JG3B-L
F39-JG5B-L
F39-JG7B-L
F39-JG10B-L
F39-JG15B-L
F39-JG20B-L
F39-JGR5B-D
F39-JG1B-D
F39-JG3B-D
F39-JG5B-D
F39-JG7B-D
F39-JG10B-D
F39-JG15B-D
F39-JG20B-D
63
64
F3W-MA
4-Joint Plug/Socket Connector
Used for reduced wiring for connecting F3W-MA with F3SG-RA.
Appearance Type Specifications
F3SG-RA
Emitter
For emitter
M12 connectors.
Used for reduced wiring.
F3W-MA Emitter
(Primary)
4-joint plug/
Socket Connector
F39-GCN4-L
F3W-MA Emitter
(Secondary)
Single-ended Connector Cable
F39-JG
@A-L (Gray)
F3SG-RA
Receiver
For receiver(PNP output)
M12 connectors.
Used for reduced wiring.
F3W-MA Receiver
(Primary)
4-joint plug/
Socket Connector
F39-GCN4-D
F3W-MA Receiver
(Secondary)
Single-ended Connector Cable
F39-JG
@A-D (Black)
Model
F39-GCN4-L
F39-GCN4-D
Includes one each of
F39-GCN4-L and
F39-GCN4-D
−
Sensor Mounting Brackets
Appearance Specification
Standard
Adjustable
Bracket
Application Remarks
Standard
Fixed Bracket
Bracket to mount the F3W-MA.
Side mounting and backside mounting possible.
Two brackets per set
Bracket to mount the F3W-MA.
Beam alignment after mounting possible.The angle adjustment range is
±15°.
Side mounting and backside mounting possible.
Two brackets per set
F39-GCN4
Model
F39-LGF
F39-LGA
F3W-MA
Ratings/Specifications
Extension of Power Cable
F3W-MA0100P F3W-MA0300P
Performance
Beam Gap between Muting Trigger
Beams
Number of Beams
Standard Detection Object
Operating
Range
Long
Short
Response Time
Operation
Reset
Degree of Protection (IEC 60529)
Vibration Resistance (IEC 61496-1)
Shock Resistance (IEC 61496-1)
Pollution Degree (IEC 60664-1)
100mm
8
300mm
20
30mm
0.3 to 20.0 m (1 to 65 ft.)
0.3 to 7.0 m (1 to 23 ft.)
13 ms max.
26 ms max. (Synchronized)
78 ms max. (Not synchronized)
±2.5° max., emitter and receiver at operating range of 3 m or greater
Electrical
Functional
Environmental
Effective Aperture Angle
Light Source
Startup Waiting Time
Power Supply Voltage (Vs)
Current
Consumption
Emitter
Receiver
Functions
Ambient
Temperature
Ambient
Humidity
Operating
Storage
Operating
Storage
Ambient Illuminance
Infrared LEDs, Wavelength: 870 nm
2 s max.
SELV/PELV 24 VDC
±20% (ripple p-p 10% max.)
35mA 45mA
Muting Outputs
Output Operation Mode
Input Voltage
* This product is a PNP output model. Use with the PNP output model safety light curtain.
Muting Output A
Dark-ON
(Muting Output A is enabled when MuteA trigger beam is blocked.)
Muting Output B
ON Voltage
Dark-ON
(Muting Output B is enabled when MuteB trigger beam is blocked.)
[MuteEnable]
Vs to Vs-3 V (sink current 5 mA max.) *
OFF Voltage
[Mute Enable]
0 to 1/2 Vs, or open *
* The Vs indicates a supply voltage value in your environment.
Indicators
Protective Circuit
Insulation Resistance
Refer to page 66. LED Indicator Status
Protective Circuit Output short protection, Power supply reverse polarity protection
20 M
Ω or higher (500 VDC megger)
Dielectric Strength
75mA 75mA
Two PNP transistor outputs. *
Load current of 300 mA max.,
Residual voltage of 2 V max. (except for voltage drop due to cable extension)j
1,000 VAC, 50/60 Hz (1 min)
- Scan Code Selection
- Operation Mode Selection (Point to Point Detection/ Chattering and Void Space
Prevention)
- Off-Delay
- Muting Enable
- Muting Trigger Beam Allocation
- Operating Range Selection
-10 to 55
°C (13 to 131°F) (non-icing)
-25 to 70
°C (-13 to 158°F)
35% to 85% (non-condensing)
35% to 95%
Incandescent lamp: 3,000 Ix max. on receiver surface
Sunlight: 10,000 Ix max. on receiver surface
IP65 and IP67
10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps for all 3 axes
100 m/s
2
, 1000 shocks for all 3 axes
Pollution Degree 3
Connections
Material
Weight (packaged)
Included Accessories
100 m max.
Note: For T-Shaped configuration with COM lines, the length of cable extension is 30m max.
Housing: Aluminum, Cap: PBT, Front Window: PMMA, Cable: Oil resistant PVC, FE plate: SUS
1.8 kg max.
Instruction Sheet
2.8 kg max.
65
66
F3W-MA
LED Indicator Status
Shown below are indication statuses of F3W-MA LED indicators when you purchased.
Emitter
Name of Indicator
Operating range LONG
Running
Error
RUN
ERR
Color Illuminated
Green Long Range mode is selected by DIP Switch.
Green Power is ON.
Red -
Receiver
Name of Indicator
Top-beam-state TOP
Muting output A
Muting output B
MUTE A
MUTE B
Off-Delay
Chattering/ Void space
DELAY
CHAT
Muting Enable
Error
Stable-state
Running
MUTE
DISABLE
ERR
STB
RUN
Communication
Bottom-beamstate
COM
BTM
Blinking
-
-
Error in emitter. Generic error happens.
Color Illuminated
Blue The top beam is unblocked.
Green
Green
Muting Output A is activated.
Muting Output B is activated.
Blinking
-
-
-
-
Yellow Off-Delay function is enabled by DIP Switch.
Green
Chattering and Void Space Prevention mode is selected by DIP Switch.
-
Red
The Muting Enable function is enabled and Muting
Enable input is turned OFF by DIP Switch.
-
-
Red
-
Green Incident light level is 170% or higher of ON-threshold
Error in receiver. Generic error happens.
-
Green Power is ON.
Green
Synchronization between emitter and receiver is maintained.
-
[Primary sensor]
- Start-up (for approx. 3 s)
- Synchronization between emitter and receiver is lost
Blue The bottom beam is unblocked.
F3W-MA
Wiring Examples
Standard Muting Mode with F3SG-R (T-Shaped Configuration with COM lines)
The following is the example of F3W-MA with Scan Code B, Chattering and Void Space Prevention 1, Off-Delay 100 ms and Muting Enable disabled.
DIP Switch settings *1
Function
Scan Code B (factory default setting)
1
DIP-SW1
ON
DIP-SW2 *2
1 ON
Chattering and Void Space Prevention 1
2
3
ON
ON
2
3
ON
ON
F3W-MA Primary
Receiver
Off-Delay 100 ms
4
5
ON
ON
4
5
ON
ON
Muting Enable Disabled (factory default setting)
6 ON 6 ON
Emitter Scan Code B (factory default setting)
1 ON
−
F3W-MA Secondary
Receiver
Emitter
−
No setting required No setting required
: Indicates a switch position.
*1.Configure functions with the DIP Switches before wiring. Refer to Smart Muting Actuator F3W-MA Series User's Manual for more information.
*2.DIP Switch Bank 2 is not used.
Wiring example
[Emitter]
F3W-MA Emitter
(Primary)
F39-JG
@A-L
Functional Earth Functional Earth
F3W-MA Emitter
(Secondary)
F39-JG
@A-L
[Receiver]
*1. Signal wiring of the F3W-MA is not required.
*2. Do not connect CFG In line to +24 VDC line. Otherwise, F3W-MA enters the error state.
F3W-MA Receiver
(Primary)
F39-JG
@A-D
Functional Earth Functional Earth
F3W-MA Receiver
(Secondary)
F39-JG
@A-D
+24 VDC
0 VDC
+24 VDC
0 VDC
Note: The wiring examples in later pages do not indicate functional earth. To use functional earth, wire an earth cable according to the example above. Refer to Smart Muting Actuator F3W-MA Series User's Manual for more information.
67
68
F3W-MA
Standard Muting Mode with F3SG-R (T-Shaped Configuration with 4-Joint Connector)
The following is the example of F3SG-RA with Scan Code B, External Device Monitoring disabled, Auto Reset mode, PNP output and External
Test in 24 V Active, and F3W-MA with Scan Code A, Chattering and Void Space Prevention 1, Off-Delay 100 ms and Muting Enable disabled.
DIP Switch settings*1
Scan Code B
Function
1
DIP-SW1
ON 1
DIP-SW2
ON
EDM Disabled (factory default setting)
2 ON 2 ON
Receiver
3 ON 3 ON
Auto Reset (factory default setting)
F3SG-RA
4 ON 4 ON
PNP (factory default setting)
7 ON 7 ON
Emitter
Scan Code B
External Test: 24 V Active (factory default setting)
1
4
ON
ON
−
−
Scan Code A
1 ON 1 ON
*2
F3W-MA Primary
Receiver
Chattering and Void Space Prevention 1
Off-Delay 100 ms
Muting Enable Disabled (factory default setting)
2
3
4
5
6
ON
ON
ON
ON
ON
2
3
4
5
6
ON
*2
ON
*2
ON
*2
ON
*2
ON
*2
Emitter Scan Code A
1 ON
−
F3W-MA Secondary
Receiver
Emitter
−
No setting required No setting required
: Indicates a switch position.
*1.Configure functions with the DIP Switches before wiring. For the DIP Switch of the F3W-MA, refer to Smart Muting Actuator F3W-MA Series User's Manual. For the
DIP Switch of the F3SG-RA, refer to the Safety Light Curtain F3SG-R Series User's Manual.
*2.DIP Switch Bank 2 of F3W-MA receiver is not used.
Wiring example
F3W-MA Emitter
(Primary)
F39-GCN4-L
F39-JG
@A-L
F3W-MA Emitter
(Secondary)
F3W-MA Receiver
(Primary)
F39-GCN4-D
F39-JG
@A-D
F3W-MA Receiver
(Secondary)
S1
S2
*2
ML
S1: Test Switch (Connect the line to 0 V if this switch is not required)
S2: Lockout/Interlock Reset Switch, Override Switch or Override Cancel Switch
ML: Muting lamp
*1. Also used as Override input line.
*2. Make sure to connect an override cancel switch to the Reset line when using the override function.
Otherwise the override state may not be released by the override cancel switch, resulting in serious injury.
*3. Refer to page 29 for more information on connectable safety controller units.
IN1 IN2
Safety
Controller *3
+24 VDC
Power Supply
0 VDC
F3W-MA
Exit-Only Muting Mode with F3SG-R (L-Shaped Configuration)
The following is the example of F3W-MA with Scan Code A, Chattering and Void Space Prevention 1, Off-Delay 100 ms and Muting Enable enabled.
DIP Switch settings*1
Scan Code A
Function
1
DIP-SW1
ON
DIP-SW2 *2
1 ON
Chattering and Void Space Prevention 1
2
3
ON
ON
2
3
ON
ON
F3W-MA
Receiver
Off-Delay 100 ms
4
5
ON
ON
4
5
ON
ON
Muting Enable Enabled
6 ON 6 ON
Emitter Scan Code A
1 ON
−
: Indicates a switch position.
*1.Configure functions with the DIP Switches before wiring. Refer to Smart Muting Actuator F3W-MA Series User's Manual for more information.
*2.DIP Switch Bank 2 is not used.
Wiring example
[Emitter]
F3W-MA Emitter
F39-JG
@A-L
[Receiver]
+24 VDC
0 VDC
*1. Signal wiring of the F3W-MA is not required.
*2. Do not connect CFG In line to +24 VDC line. Otherwise, F3W-MA enters the error state.
F3W-MA Receiver
F39-JG
@A-D
S1
S1: Mute Enable Switch
+24 VDC
0 VDC
69
70
F3W-MA
Exit-Only Muting Mode with F3SG-R (L-Shaped Configuration with 4-Joint Connector)
The following is the example of F3SG-RA with Scan Code A, External Device Monitoring disabled, Auto Reset mode, PNP output and External
Test in 24 V Active, and F3W-MA with Scan Code B, Chattering and Void Space Prevention 1, Off-Delay 100 ms and Muting Enable enabled.
DIP Switch settings*1
Function
Scan Code A (factory default setting)
1
DIP-SW1
ON 1
DIP-SW2
ON
EDM Disabled (factory default setting)
2 ON 2 ON
Receiver
3 ON 3 ON
Auto Reset (factory default setting)
F3SG-RA
4 ON 4 ON
PNP (factory default setting)
7 ON 7 ON
Emitter
Scan Code A (factory default setting)
External Test: 24 V Active (factory default setting)
1
4
ON
ON
−
−
Scan Code B (factory default setting)
1 ON 1 ON
*2
F3W-MA
Receiver
Chattering and Void Space Prevention 1
Off-Delay 100 ms
2
3
4
5
ON
ON
ON
ON
2
3
4
5
ON
*2
ON
*2
ON
ON
*2
*2
Muting Enable Enabled
6 ON 6 ON
*2
Emitter Scan Code B (factory default setting)
1 ON
−
: Indicates a switch position.
*1.Configure functions with the DIP Switches before wiring. For the DIP Switch of the F3W-MA, refer to Smart Muting Actuator F3W-MA Series User's Manual. For the
DIP Switch of the F3SG-RA, refer to the Safety Light Curtain F3SG-R Series User's Manual.
*2.DIP Switch Bank 2 of F3W-MA receiver is not used.
Wiring example
F3W-MA Emitter
(Primary)
F39-GCN4-L
F39-JG
@A-L
F3W-MA Receiver
(Primary)
F39-GCN4-D
F39-JG
@A-D
S1
S2
*2
S3
ML
S1: Test Switch (Connect the line to 0 V if this switch is not required)
S2: Lockout/Interlock Reset Switch, Override Switch or Override Cancel Switch
S3: Muting Enable Switch
ML: Muting lamp
IN1 IN2
Safety
Controller *3
*1. Also used as Override input line.
*2. Make sure to connect an override cancel switch to the Reset line when using the override function. Otherwise the override state may not be released by the override cancel switch, resulting in serious injury.
*3. Refer to page 29 for more information on connectable safety controller units.
+24 VDC
Power Supply
0 VDC
F3W-MA
Standard Muting Mode with Other Safety Component (T-Shaped Configuration)
The following is the example of F3W-MA-1 with Scan Code A, Chattering and Void Space Prevention 1, Off-Delay 100 ms and Muting Enable enabled, and F3W-MA-2 with Scan Code B, Chattering and Void Space Prevention 1, Off-Delay 100 ms and Muting Enable enabled.
DIP Switch settings*1
F3W-MA-1
Receiver
Scan Code A
Off-Delay 100 ms
Function
Chattering and Void Space Prevention 1
2
3
4
5
6
1
DIP-SW1
ON
ON
ON
ON
ON
ON
DIP-SW2 *2
1 ON
2
3
4
5
6
ON
ON
ON
ON
ON
−
Emitter
Muting Enable Enabled
Scan Code A
Scan Code B (factory default setting)
1 ON
1 ON 1 ON
F3W-MA-2
Receiver
Chattering and Void Space Prevention 1
Off-Delay 100 ms
2
3
4
5
ON
ON
ON
ON
2
3
4
5
ON
ON
ON
ON
Muting Enable Enabled
6 ON 6 ON
Emitter Scan Code B (factory default setting)
1 ON
−
: Indicates a switch position
.
*1.Configure functions with the DIP Switches before wiring. For the DIP Switch of the F3W-MA, refer to Smart Muting Actuator F3W-MA Series User's Manual. For the
DIP Switch of the F3SG-RA, refer to the Safety Light Curtain F3SG-R Series User's Manual.
*2.DIP Switch Bank 2 is not used.
Wiring example
[Emitter]
[SLC settings]
- Muting system
- Emitters and receivers of F3W-MA and SLC mounted in alternation
F3W-MA Emitter 1
F39-JG A-L
F3W-MA Emitter 2
F39-JG A-L
[Receiver]
*1. Signal wiring of the F3W-MA is not required.
F3W-MA Receiver 1
F39-JG
@A-D
+24 VDC
0 VDC
[SLC settings]
- Muting system
- Emitters and receivers of F3W-MA and
SLC mounted back-to-back
F3W-MA Receiver 2
F39-JG
@A-D
S1
S1: Mute Enable Switch
IN1 IN2
Safety
Controller *2
*1. Signal wiring of the F3W-MA is not required.
*2. Connectable Safety Control Units:
NE1A and G9SP series with a muting function
+24 VDC
0 VDC
71
72
F3W-MA
Input/Output Circuit
The entire circuit diagram of the F3W-MA is shown below.
The numbers in the circles indicate the connector's pin numbers.
Indicator
1
Brown
+24 VDC
Emitter
Main Circuit
Receiver
Main Circuit 2
Receiver
Main Circuit 1
Indicator
3
Blue
Muting Enable input circuit
2
Brown
1
Yellow Muting Enable
6
White Muting Output B
5
Black Muting Output A
Load
Load
7
Blue
0 VDC
Mounted with Standard Adjustable Brackets (F39-LGA)
Mounted with Standard Adjustable Brackets (F39-LGA)
Backside Mounting
F3W-MA
(Unit : mm)
35
Standard
Adjustable Bracket
(F39-LGA)
48.6
35
2-M5 or M6
Standard
Adjustable Bracket
(F39-LGA)
9.2
24.85
2-M5 or M6
24.85
< Screw: M5 or M6 >
Model
Dimension A
Dimension C1
Dimension D
Dimension P
Number of Standard
Adjustable Brackets *
F3W-MA0100P
208
190
140
20
2
F3W-MA0300P
448
430
380
20
2
* The number of brackets required to mount either one of emitter and receiver.
73
F3W-MA
Side Mounting
Standard
Adjustable Bracket
(F39-LGA)
48.6
35 35
2-M5 or M6
Standard
Adjustable Bracket
(F39-LGA)
9.2
42.35
2-M5 or M6
74
< Screw: M5 or M6 >
Model
Dimension A
Dimension C1
Dimension D
Dimension P
Number of Standard
Adjustable Brackets *
F3W-MA0100P
208
190
140
20
2
F3W-MA0300P
448
430
380
20
2
* The number of brackets required to mount either one of emitter and receiver.
Standard Adjustable Bracket (F39-LGA)
42
45.1
84
Material: ZDC2, Fluorine-containing lubricant
34.5
31.8
6.4
72
Mounted with Standard Fixed Brackets (F39-LGF)
Backside Mounting
40
35 35
Standard
Fixed Bracket
(F39-LGF)
2-M5 or M6
Standard
Fixed Bracket
(F39-LGF)
9.2
24.85
2-M5 or M6
24.85
< Screw: M5 or M6 >
Model
Dimension A
Dimension C1
Dimension D
Dimension P
Number of Standard
Fixed Brackets *
F3W-MA0100P
208
190
140
20
2
F3W-MA0300P
448
430
380
20
2
* The number of brackets required to mount either one of emitter and receiver.
F3W-MA
75
F3W-MA
Side Mounting
Standard
Fixed Bracket
(F39-LGF)
40
35 35
2-M5 or M6
Standard
Fixed Bracket
(F39-LGF)
9.2
42.35
2-M5 or M6
< Screw: M5 or M6 >
Model
Dimension A
Dimension C1
Dimension D
Dimension P
Number of Standard
Fixed Brackets *
F3W-MA0100P
208
190
140
20
2
F3W-MA0300P
448
430
380
20
2
* The number of brackets required to mount either one of emitter and receiver.
76
Standard Fixed Bracket (F39-LGF)
36
66
(25.8)
(23.1)
6.4
Material: ZDC2
51
Accessories
Single-Ended Cable for Emitter (F39-JG
A-L, sold separately)
L
40.7
M12 IP67 connector
Insulated vinyl round cable dia. 6.6, 5-wire
(Cross section of conductor: 0.38 mm 2 /insulator diameter: dia. 1.2 mm)
Single-Ended Cable for Receiver (F39-JG
A-D, sold separately)
L
40.7
Emitter cable (Gray)
F39-JG3A-L
F39-JG7A-L
F39-JG10A-L
F39-JG15A-L
F39-JG20A-L
M12 IP67 connector
Insulated vinyl round cable dia. 6.6, 8-wire
(Cross section of conductor: 0.38 mm
2
/insulator diameter: dia. 1.2 mm)
Receiver cable (Black)
F39-JG3A-D
F39-JG7A-D
F39-JG10A-D
F39-JG15A-D
F39-JG20A-D
L (m)
3
7
10
15
20
F3W-MA
77
78
F3W-MA
Double-ended Cable for Emitter: Cable for extension (F39-JG
B-L, sold separately)
L
44.7
40.7
M12 IP67 connector
M12 IP67 connector
Insulated vinyl round cable dia. 6.6, 5-wire (2-pair + 1)
(Cross section of conductor: 0.38 mm 2 /insulator diameter: dia. 1.2 mm)
Emitter cable (Gray)
F39-JGR5B-L
F39-JG1B-L
F39-JG3B-L
F39-JG5B-L
F39-JG7B-L
F39-JG10B-L
F39-JG15B-L
F39-JG20B-L
Receiver cable (Black)
F39-JGR15B-D
F39-JG1B-D
F39-JG3B-D
F39-JG5B-D
F39-JG7B-D
F39-JG10B-D
F39-JG15B-D
F39-JG20B-D
L (m)
0.5
5
7
1
3
10
15
20
4-Joint Plug/Socket Connector for Emitter (F39-GCN4-L, sold separately)
58.3
17 13.6
MA2
CN
2
1
4
3
5
M12 x 1
SLC
2-dia. 5.5
1
4
2
5
3
M12 x 1
MA1
2-dia.10
7
27
Material: PBT (Main body)
4-Joint Plug/Socket Connector for Receiver (F39-GCN4-D, sold separately)
58.3
17 13.6
MA2
CN
1
6
7
2
1
2
7
6
3
4
5
8
M12 x 1
SLC
2-dia.5.5
5
8
4
3
M12 x 1
MA1
2-dia.10
7
27
Material: PBT (Main body)
Related Manuals
ManNo.
Z355
F3W-MA
Model Manual name
Smart Muting Actuator F3W-MA Series User's Manual
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE
PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL
SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Industrial Automation Company
Tokyo, JAPAN
Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69, 2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
Authorized Distributor:
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
© OMRON Corporation 2014-2015 All Rights Reserved.
In the interest of product improvement, specifications are subject to change without notice.
CSM_6_1_0915
Cat. No. F094-E1-04
Printed in Japan
0915(1214)
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 1 Safety Light Curtain F3SG-R Series Promotional Brochure
- 2 Next generation safety light curtain
- 4 Robustness
- 5 New Muting Functionality
- 6 Powerful Features
- 8 Wiring, Beam Adjustment, and Operation Check
- 10 Troubleshooting and Predictive Maintenance
- 12 Safety Light Curtain Advance type F3SG-RA
- 12 Ordering Information
- 16 Ratings and Specifications
- 18 List of Models/Response Time/Current Consumption/Weight
- 19 Legislation and Standards
- 20 Indicator
- 21 Connections (Basic Wiring Diagram)
- 34 Input/Output Circuit
- 36 Dimensions
- 45 Safety Light Curtain Easy type F3SG-RE
- 45 Ordering Information
- 48 Ratings/Specifications
- 50 List of Models/Response Time/Current Consumption/Weight
- 51 LED Indicator Status
- 52 Connections (Basic Wiring Diagram)
- 54 Input/Output Circuit
- 56 Dimensions
- 63 Smart Muting Actuator F3W-MA
- 63 Ordering Information
- 65 Ratings/Specifications
- 66 LED Indicator Status
- 67 Wiring Examples
- 72 Input/Output Circuit
- 73 Mounted with Standard Adjustable Brackets (F39-LGA)